This file is a Questions and Responses document for Federal Bureau of Investigation (FBI) Criminal Justice Information Services (CJIS) Division's Request for Quotations (RFQ) 15F06727Q0000010 for Window Cleaning and Maintenance Services at the CJIS facility in Clarksburg, West Virginia. The document addresses 71 quoter inquiries across administrative, technical, pricing, and operational topics, with government responses clarifying solicitation requirements. This is a 100% small business set-aside acquisition for a single firm-fixed-price contract consisting of a base year plus four one-year option periods, with the current contract expiring January 20, 2027, and the new contract anticipated to start January 21, 2027. Quotations are due November 24, 2026, at 10:00 AM ET, with a mandatory site visit moved to November 6, 2026, at 9:00 AM ET requiring Visitor Access Request form submission by November 2, 2026.
The requirement encompasses scheduled interior and exterior window cleaning of approximately 320,049 square feet in the base year (including two annual cleanings of the CJIS Main Building), annual window inspections covering both the Main Building and Building Technical Center (BTC), specialized services including high-dusting and hanging-light cleaning in the Visitors Center and atriums, and emergency response within 24 hours for window securing and repairs. The NAICS code is 561720 with a $22 million size standard. Pricing shall be submitted as annual firm-fixed prices for all recurring services and inspection work; option year pricing includes additional specialized cleaning of BTC Stair 6 (Year 1) and BTC interior curtain wall cores (Year 2). All personnel must complete FBI security clearance requirements (LAR paperwork) and will be escorted by FBI employees during site work. The government will provide facility drawings to the successful bidder, designate a temporary equipment laydown area, and supply water and electrical power on-site. Invoicing must be submitted via IPP.gov following service completion and government acceptance, with no monthly progress invoicing permitted.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Sheet1
| 15F06727Q0000010 - Window Cleaning and Maintenance Services | |||||
| # | Reference | Quoter's Questions | Governent's Response | Amendment 1 | Amendment 2 |
| 1 | General | Is this a brand new contract OR if there is (was) an incumbent performing these services. | New contract (base year + 4 (one-year options). Current contract expires on 01/20/2027. | X | |
| 2 | Quotation due date/SF1449 | The RFQ document states quotations are due November 24, 2026 at 10:00 AM ET, while the SAM.gov notice description states November 18, 2026 at 2:00 PM ET, and the SF 1449 form (Block 8) states November 16, 2026 at 11:00 AM ET. Could you please confirm which date and time governs, and whether an amendment will be issued to reconcile them? | Quotes are due 11/24/2026 at 10:00AM, ET. The SF1449 and SAM.gov decription has been revised to reflect this. | X | |
| 3 | Invoicing/Statement of Work | Statement of Work directs invoices to central_invoices@fbi.gov, while the SF 1449 states invoices should be submitted via IPP and not to central_invoices@fbi.gov. Could you please confirm the correct invoicing channel? | IPP.gov is the Government's invoicing platform. The SOW has been revised to reflect this. | X | |
| 4 | Site Visit | Is attendance at the site visit mandatory for a quotation to be considered technically acceptable? | Attendance is not mandatory, but strongly encouraged. | X | |
| 5 | Site Visit | Would there be any possibility of visiting the site on an alternate date? | Site Visit is date has been moved to 11/06/2026, 9AM, ET, to allow time for VAR submittal and approval. No other alternate is provided. | X | |
| 6 | Site Visit | May a subcontractor representative attend the site visit on behalf of the prime contractor? | Yes. A sub can attend. | X | |
| 7 | Site Visit | What is the deadline for submitting the Visitor Access Request form for the site visit? | VARs shall be submitted no later than 11/02/2026 in order for security to conduct review and provide approval. | X | |
| 8 | Site Visit | Will the attendee list be shared after the visit? | No. The Government will not distribute the site visit attendee list. | X | |
| 9 | Site Visit | How should we send forms that contain SSNs? | VARs shall be submitted to ckesselman@fbi.gov. | X | |
| 10 | Site Visit | Site visit approval submission method, and check-in instructions for site visit? | Approval will be provided by security to the CO. Once aproval is granted, CO will provided site visit instructions via email to the attending company's. | X | |
| 11 | Incumbent | For market research purposes, could you please share the previous contract amount, the previous awardee, and the previous period of performance for this requirement, if available? | AFM is the current contractor. The period of performance ends 01/20/2027. | X | |
| 12 | X | ||||
| 13 | NAICS Code | NAICS: The RFQ letter lists 561720 ($22.0M) and the SF1449 lists 561790 ($9M). Which NAICS code and size standard apply? | The NAICS code is 561720. Size standard is $22M. The SF1449 has been revised to reflect this. | X | |
| 14 | Clauses | The SF1449 clause, provision and attachment sections are marked "intentionally left blank," and 52.212-5 is referenced but not attached. Please provide the full clause list, including whether 52.219-14 Limitations on Subcontracting, 52.222-41 with WD 2015-4353, and 52.228-5 apply. | See attachment "15F06727Q0000010 - SF1449 - R1.pdf" | X | |
| 15 | Clauses | Please provide the applicable clauses and provisions, including the FAR 52.212-5 attachment referenced in SF1449 Block 27a and any limitations-on-subcontracting clause or agency deviation. The SF1449 sections for clauses and provisions are marked intentionally blank. | See attachment "15F06727Q0000010 - SF1449 - R1.pdf" | X | |
| 16 | Pricing | Option prices: Does "option prices must include the special work" mean the Option 1 (Stair 6) and Option 2 (BTC interior cores) areas only, or other work too? | Yes. Option Year 1 pricing shall include the additional BTC Stair 6 cleaning, and Option Year 2 pricing shall include the additional BTC interior curtain wall cores cleaning. Base and ALL option years (1/4) must also include all regularly scheduled cleaning and inspection services required by the SOW. | X | |
| 17 | Inspection Day Rate | Is the inspection day rate in the supporting schedule evaluated, and how many inspection days does the Government expect? | Offerors shall provide an annual firm-fixed price for all inspection services required by the SOW for each contract period. Offerors are responsible for estimating the number of inspection days necessary. The inspection day rate is supporting pricing information only; the annual firm-fixed price will be used for evaluation. | X | |
| 18 | Repairs | Would glazing repair or replacement work be ordered under this contract with Davis-Bacon wage rates, and is a West Virginia contractor license required? | Glazing repairs and replacements may be ordered on a case-by-case basis, subject to separate pricing, funding, and written Contracting Officer authorization. Applicable Davis-Bacon labor requirements will be determined based on the scope of each order. Contractors are responsible for obtaining and maintaining any West Virginia licenses required for the work performed. | X | |
| 19 | Security | To meet the 1/21/2027 start, by what date do personnel forms need to reach the FBI after award? Can escorted access (FD-816/FD-484) be used for the first cleaning while recurring-access paperwork is processed? | See question #64 | X | |
| 20 | Anchoring | Will the Government accept portable, non-penetrating davit/counterweight systems on the Main Building roof, and what does the CJIS Safety approval submittal need to include? | See question #57 | X | |
| 21 | Prime contractor eligibility | May ROA compete under the proposed arrangement? Are any tasks required to be performed directly by ROA employees? | Yes. If they meet the standards of the solicitation. | X | |
| 22 | Experience | May the documented experience and resources of named, committed subcontractors satisfy the technical experience requirements, or must the comparable projects have been performed by the proposing entity itself? Are there minimum years of experience or project-size requirements? | See question #53 | X | |
| 23 | Sub-Contracting Limitations | Which limitations on subcontracting apply, and how would work performed by similarly situated small-business subcontractors be treated? Please confirm the applicable clauses and measurement period. | FAR 52.219-6 and FAR 52.219-14 are incorporated into the solicitation. The Contractor shall not pay more than 50% of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Work performed by qualifying similarly situated subcontractors is excluded from this limitation; however, any work further subcontracted by those entities will count toward the limitation. |
| Compliance will be measured at the end of the base contract period and each subsequent option period. The solicitation will be amended to reflect the appropriate selection under FAR 52.219-14(f)(1). | X | ||||
| 24 | Cleaning quantities and inspection scope: | Do the listed square-footage totals include both interior and exterior glass surfaces and the Main Building’s second annual cleaning? Could you provide a building-by-building breakdown and confirm that annual inspections cover both the Main Building and BTC? | See question #56 | X | |
| 25 | Personnel access and startup | Which screening requirements and forms apply to recurring personnel and emergency responders? How should contractors reconcile the SOW’s 60-day advance submission requirement with the anticipated award date and January 21, 2027 start? | Packets of forms for site access will be provided to the selected/awarded contractor. Typically there is a 2 week turnaround once completed forms are turned in to security access. | X | |
| 26 | Emergency response and repair pricing: | Please confirm that emergency labor rates must be submitted initially, while repairs and replacements are quoted separately after a requirement is identified. How will written authorization, funding and site access be coordinated to meet the 24-hour response requirement? | If an emergency happens the contractor has a 24 response to to arrive onsite to evaluate and make safe a broken window and then provide an estimate for the repair. | X | |
| 27 | Additional qualification requirements | Pleaase identify any required licenses, insurance limits, bonds or specific personnel certifications beyond the safety and access requirements already described. | The solicitation does not establish specific insurance limits, bonding requirements, or additional personnel certifications beyond those identified in the solicitation and SOW Contractors are responsible for obtaining and maintaining all applicable federal, state, and local licenses, permits, and insurance required to perform the services. | X | |
| 28 | Incumbent | Could you provide the current incumbent’s legal name, contract number, most recent annual recurring contract value, and any publicly releasable historical emergency-service volume? | AFM is the current contractor. The period of performance ends 01/20/2027. The Government will not provide incumbent historical emergency-service volume as part of this solicitation. Publicly available contract award information may be obtained through open source searches by the Contractor as part of their own Market Research. Offerors shall prepare their quotations based on the requirements identified in the solicitation and SOW. | X | |
| 29 | Sub-Contracting | Beyond the standard limitations on subcontracting applicable to a 100% small business set-aside, does this requirement impose any additional restriction on the use of subcontractors? We also confirm our understanding that all personnel performing on site must meet the SOW Section 8.2 access requirements (FBI Security Programs Manager approval, including escorted access where applicable). | The Government does not impose additional restrictions on the use of subcontractors beyond those established in the solicitation and applicable federal regulations. The prime contractor remains responsible for contract performance and compliance with all contractual requirements. |
| All personnel, including subcontractor personnel, performing work on-site must comply with the security and access requirements outlined in Section 8.2 of the SOW, including FBI Security Programs Manager approval and escorted access, as applicable. | X | ||||
| 30 | Insurance | Please state the required minimum insurance types and amounts. | The solicitation does not establish specific minimum insurance types or coverage amounts. Contractors are responsible for maintaining any insurance required by applicable federal, state, and local laws and regulations. | X | |
| 31 | Relevant Experience | May the offeror's relevant experience examples include work performed by a proposed subcontractor? | See question #53 | X | |
| 32 | Square Footage | For the twice-a-year Main Building cleaning, how many square feet of glass are on the Main Building versus the other buildings? Could you share building heights, the number of floors, and any elevation drawings? | Drawings will be provided as needed to the successful bidder | X | |
| 33 | Attachment 2 - Pricing Schedule | Attachment 2’s “Recurring FFP Pricing” sheet has no base-year annual-total formula in F5, while F11 sums F5. The SF1449 also appears to omit base inspection CLIN 0002. Please provide a corrected workbook/form confirming all ten recurring CLINs. | Attachment 2, Recurring FFP Pricing, and the SF 1449 will be corrected through a solicitation amendment to ensure all ten recurring CLINs are accurately reflected, including Base Year Inspection CLIN 0002. Offerors shall use the revised documents when preparing and submitting their quotations. | X | |
| 34 | Section 7 of SOW | Please confirm whether the stated annual square footage includes both glass faces and the Main Building’s second annual cleaning. Could you provide a building-level area/frequency schedule and the available curtain-wall drawings referenced in SOW Section 7? | See question #38 and #56 | X | |
| 35 | Access | SOW Section 8 references forms submitted 60 days before tasks. Please confirm the onboarding process supporting the January 21 start and approved backup personnel needed for 24-hour emergency response. | See question #70 | X | |
| 36 | Invoicing | Could you please clarify the invoicing and payment schedule for these services? Specifically, may the contractor submit an invoice after each scheduled cleaning event has been completed and accepted by the Government, including the two annual cleanings of the CJIS Main Building? Alternatively, are monthly progress invoices permitted, or must the contractor wait until all services under each annual CLIN have been completed and accepted before invoicing? | The Contractor shall submit invoices following completion of the required services and acceptance by the Government. Monthly progress invoicing is not permitted. | X | |
| 37 | Experience | Can we use our named subcontractors’ comparable project experience for Factor 3? | See question #53 | X | |
| 38 | Section 7 of SOW | Section 7 of the SOW mentions the unclassified curtain wall drawings can be provided on request. Could we request those, along with a campus site plan showing each building, so we and our team can plan equipment access and the 9-foot perimeter wall openings? | Drawings will be provided as needed to the successful bidder | X | |
| 39 | Drawings | Could you please provide the available curtain-wall drawings for our review? The drawings will assist us in evaluating access requirements, equipment selection, fall-protection needs, and the overall technical approach. | Drawings will be provided as needed to the successful bidder | X | |
| 40 | Drawings | Could you also provide the available unclassified curtain-wall drawings and confirm inspections cover both the Main Building and BTC? | Drawings will be provided as needed to the successful bidder | X | |
| 41 | Ceiling Height/Number of light fixtures | For the hanging ceiling lights and high dusting in the Visitors Center and the two atriums, about how high are the ceilings, and how many hanging fixtures are there? | 18 Lights in the Barrel vault and 32 in the Visitors atrium. | X | |
| 42 | Incumbent | Could you share the current contract number for the AFM contract and its annual value, if available? | Publicly available federal contract award information may be obtained through FPDS-NG or other open source/public sources available as part of contractor's market research. | X | |
| 43 | Roughly how often have emergency window-securing calls come up under the current contract (for example, per year)? This would help us set reasonable emergency rates. | At most once a year. | X | ||
| 44 | Window count | See question #56 | X | ||
| 45 | For the annual inspection of the CJIS Main Building and BTC, about how many window units or linear feet of curtain wall should we plan to inspect? | See question #56 | X | ||
| 46 | Glass Sq. Feet | Could you share an approximate breakdown of the 230,000 sq ft of glass by building (CJIS Main, BTC, Visitors Center, Service Center, Police Services Building and Daycare Center), and the approximate height or number of stories of each? | See question #59. Square footage update is on sheet #2. | X | |
| 47 | Security/access | How should we handle the 60-day personnel-screening lead time if award is closer to the January 21 start? | See question #70 | X | |
| 48 | SF1449 | Should the SF1449’s zero quantities be one annual lot per CLIN? | Yes. Quantities have been updated. | X | |
| 49 | Six-month extension | How should the six-month extension be priced/evaluated? | The solicitation will be amended to clarify this methodology. | X | |
| 50 | Sub-contracting | Is the subcontracting limit measured by each contract year or each order? | Compliance with the limitations on subcontracting will be measured at the end of the base contract period and at the end of each subsequent option period, in accordance with FAR 52.219-14(f)(1). The solicitation will be amended to reflect the appropriate measurement period. | X | |
| 51 | Clauses | Could you provide the complete clause set, including the referenced FAR 52.212-5? Please confirm paid sick leave/H&W, option-year wage adjustments, insurance and applicable security/FASCSA requirements. | Duplicate. Clauses have been added/updated. See SF1449 attachment. | X | |
| 52 | General | Would you consider a WOSB/EDWOSB set-aside under the rule of two in FAR 19.1505 (a reasonable expectation of offers from two or more WOSBs/EDWOSBs at a fair market price, where the NAICS is on SBA's eligible list), and a 15-minute capability conversation, by email if you prefer? A one-line pass is fine, and if another office handles this, a name is plenty. | This requirement has been established as a 100% small-business set-aside based on its acquisition planning and market research. The Government does not anticipate changing the set-aside designation for this solicitation. All eligible small businesses, including WOSBs and EDWOSBs, are encouraged to submit quotations in accordance with the solicitation requirements. |
| The Government will not conduct individual capability discussions during the solicitation period. All solicitation-related questions must be submitted in accordance with the instructions established in the RFQ. | X | ||||
| 53 | Experience | Cleaning would be done by our subcontractor, can the relevant experience examples come from jobs they've done? | Yes, that experience would be acceptable; however, the general contractor should possess sufficient relevant experience to effectively oversee and guide the subcontractor throughout the performance of the work. At a minimum, the general contractor should be able to demonstrate successful completion of at least three similar projects within the past five years that are comparable in scope, complexity, and technical requirements to the work being performed. This ensures the contractor has the expertise necessary to provide appropriate oversight, direction, and quality control for the subcontractor's activities. | X | |
| 54 | SOW 7 | SOW 7 says the curtain wall drawings may be provided on request, and we'd love to get a copy if possible. They'd help a lot with planning the fall protection, especially since we weren't sure which building is Building 5 or where the fixed cable system is on it and the BTC. | The Sucessful bidder would be provided drawings if work on the curtain wall system is needed. The fall protection is not identified on the curtain wall drawings. | X | |
| 55 | Pricing/Hanging Lights | For pricing, could you share how the 230,000 square feet breaks down by building? It would also help to know roughly how many hanging lights are in the Visitors Center and the two Main Building atriums, and about how high up they are. | The Barrel Vault hallway has 18 hanging lights, the Visitors Atrium has 32 hanging lights, the Visitors Center has 10 hanging lights. See Sheet #2 | X | |
| 56 | SOW Section 2.1 | SOW Section 2.1 states the campus has approximately 230,000 square feet of window glass cleaned once a year, and SOW Section 2 requires two cleanings yearly of the CJIS Main Building. What is the approximate glass square footage for each building, and does the 230,000 square feet include the second yearly cleaning of the Main Building? | See Sheet #2 | X | |
| 57 | SOW Section 2.1.5 | SOW Section 2.1.5 refers to "Building 5" and its partial fixed fall protection system. Which of the buildings listed in SOW Section 2 is Building 5, and where is the fixed fall protection located on Building 5 and the BTC? | Our facilities are equipped with engineered fall protection systems that are inspected annually and maintained in compliance with applicable OSHA fall protection requirements. Contractors may utilize the facility's existing fall protection infrastructure, including approved anchorage systems, as appropriate for their work activities. Contractors are required to provide and utilize their own personal fall arrest equipment, including harnesses, lanyards, self-retracting lifelines (SRLs), and connectors, and shall ensure all equipment meets applicable OSHA requirements and manufacturer specifications. For any contractor-provided standalone fall protection systems, the contractor is solely responsible for equipment inspection, maintenance, installation, use, and compliance with all applicable OSHA standards and fall protection requirements. | X | |
| 58 | SOW Section 2 | SOW Section 2 lists a yearly window inspection of the CJIS Main Building and the BTC Building, while SOW Section 2.1.2 refers only to the Main Building. Does the yearly inspection cover the Main Building only, or both the Main Building and the BTC? | The yearly window inspection covers both the CJIS Main Building and the BTC. | X | |
| 59 | SOW | How many stories, or what height, is each building, and is roof access allowed for rope access or swing stage work? (SOW Section 2.1; RFQ Section 5.B) | CJIS Main is 3 stories (~16'-6"each) aboveground and the BTC is 4 stories (~18' per floor) above ground. | X | |
| 60 | SOW | SOW Section 2.1 states a restriction on the size and weight of equipment and a nine-foot width limit. What is the equipment weight or ground-load limit, and which lift types are allowed, such as boom lifts, scissor lifts, or swing stages? (RFQ Section 5.B) | On CJIS Square the GVW limit is 19,000 lbs. During a recent cleaning the contractor used a JCB S4046E with success while cleaning the interior of CJIS Main barrel vault and Visitors Atrium. | X | |
| 61 | SOW | SOW Section 2.1 requires cleaning inside and outside of all exterior windows "except where otherwise noted." Are all interior faces included, and what are the approximate ceiling heights in the Visitors Center, Main Building Visitor Atrium, and Main Building Employee Atrium, where SOW Section 2.1.5 requires high dusting and hanging-light cleaning? | The majority of interior wall surfaces are approximately 9 feet high. Notable exceptions include the Building 5 hallway, which is approximately 33 feet in height, and portions of the Visitor Center, where wall surfaces reach approximately 20 feet in height. | X | |
| 62 | SOW | Will water and electrical power be available to the contractor on site? (SOW Section 2.1) | Yes, water and power are available. Some locations do not have easy access, so use long hoses. | X | |
| 63 | SOW | Where may contractor crews park and stage lifts, equipment, and trailers? (SOW Section 2.1 states that storage space on site may be available.) | FBI will designate a temporary laydown area for equipment. | X | |
| 64 | SOW | SOW Section 8.2 states that the FBI Security Programs Manager determines whether access is escorted or unescorted. Will window cleaning crews be escorted or unescorted, will the FBI provide escorts, and which of the security forms listed in SOW Section 8.2 will apply? | All window cleaning crews will be escorted by an FBI employee. Workers will need to complete LAR paper work before starting. | X | |
| 65 | SOW | SOW Section 8.2 states that the FBI Security Programs Manager determines whether access is escorted or unescorted. Will window cleaning crews be escorted or unescorted, will the FBI provide escorts, and which of the security forms listed in SOW Section 8.2 will apply? | All window cleaning crews will be escorted by an FBI employee. Workers will need to complete LAR paper work before starting. | X | |
| 66 | SOW | Can the most recent window inspection findings report (SOW Section 2.1.3) be shared with quoters? (Q&A item 11 identifies AFM as the current contractor.) | The Sucessful bidder would be provided a complete set. | X | |
| 67 | Could you confirm whether a qualified proposed subcontractor's representative may attend the site visit on behalf of the prime offeror, how to submit the visit request form and the deadline for access approval? Also, can the proposed subcontractor's directly relevant window maintenance and glazing repair experience be used to establish technical acceptability, subject to prime oversight and all applicable small-business subcontracting rules? | Yes, the qualified subcontractor can attend the site visit. all paperwork will need completed before the 11/2/26 deadline. Please see the response to question #53 | X | ||
| 68 | RFQ | Under RFQ sections 5–6, may a prime demonstrate relevant experience/resources through a named proposed subcontractor performing that work, with experience clearly attributed, or must the prime independently possess that experience? What commitment evidence is required? | Please see the response to question #53 | X | |
| 69 | For recurring cleaning, glazing inspections/repairs and emergency responders, which escorted/unescorted access and investigation tiers apply? RFQ section 7 says classified information and FBI system access are not required, while SOW section 8.2 describes several tiers. Does the FBI initiate and sponsor required processing after award, and must any personnel already hold approvals at quotation or award? | The FBI will initiate and sponsor all required processing following contract award. All personnel working on site must be granted LAR access prior to the commencement of any work. | X | ||
| 70 | SOW Section 8.2 | SOW section 8.2 describes post-award forms based on assignment length/nature and a 60-day submission lead time, alongside separate short-visit provisions. Which personnel does that lead time cover here? If counted from January 21, 2027, it falls on November 22, before the November 24 quote deadline. What onboarding schedule should quoters use? | There will be time post award for the contractor to submitt access forms to get crews approved. | X | |
| 71 | How should approved primary and backup emergency responders obtain after-hours access to meet the requirement to secure damaged openings within 24 hours? Are escorts/interim approvals available, or must responders be fully preapproved before performance? | The COR for the contract would arrainge access, but the responding crew would already need have an approved LAR to be placed on the access list. | X |
Sheet2
| Cost Area | Total square feet per cost item | Base year square feet cleaned | Out Year 1 square feet cleaned | Out Year 2 square feet cleaned | Out Year 3 square feet cleaned | Out Year 4 square feet cleaned |
| CJIS Main inside cleaning | 41,679 | 41,679 | 41,679 | 41,679 | 41,679 | 41,679 |
| CJIS Main outside cleaning | 79,776 | 79,776 | 79,776 | 79,776 | 79,776 | 79,776 |
| CJIS Main 2nd outside cleaning | 79,776 | 79,776 | 79,776 | 79,776 | 79,776 | 79,776 |
| BTC Inside cleaning | 9,665 | 9,665 | 9,665 | 9,665 | 9,665 | 9,665 |
| BTC Outside Cleaning | 105,109 | 105,109 | 105,109 | 105,109 | 105,109 | 105,109 |
| BTC Interior Core Cleaning Adds | 146,648 | 146,648 | ||||
| Stair #6 Cleaning Adds | 2,250 | 2,250 | ||||
| Visitors Center | 2,138 | 2,138 | 2,138 | 2,138 | 2,138 | 2,138 |
| Daycare outside cleaning | 1,370 | 1,370 | 1,370 | 1,370 | 1,370 | 1,370 |
| Service Center outside cleaning | 224 | 224 | 224 | 224 | 224 | 224 |
| Automotive | 67 | 67 | 67 | 67 | 67 | 67 |
| Police building outside cleaning | 245 | 245 | 245 | 245 | 245 | 245 |
| Total Square Feet Cleaned by Year | 320,049 | 322,299 | 466,697 | 320,049 | 320,049 |