A7_03_WALL_SECTIONS_-_122022_0004.pdf

PDF 391 KB Posted

Attached to
Hoover Dam Visitor Center Exhibit Level & Renovate
Solicitation number
140R3023R0003
Issued by

About this file

This document package includes construction drawings and specifications for a federal contract opportunity to renovate the exhibit level and office space at the Hoover Dam Visitor Center. The Bureau of Reclamation is soliciting bids to provide construction services including framing and installing drywall and finishes on curved walls to create new display, seating, and office areas. Subcontractors should verify all dimensions and site conditions before beginning work. Bids are due by December 15th, 2022 under Solicitation Number 140R3023R0003. The construction drawings provide details on framing layout, wall sections, and finish specifications to complete the renovations.

View the file

Other files

File Type Posted
E6_02_ELECTRICAL_SCHEDULES_122022_0004.pdf PDF
140R3023R0003_-_Questions_and_Responses_-Amd_No__0004_0004.pdf PDF
A2_41_EXHIBIT_LEVEL_-_FINISH_FLOOR_PLAN_-_122022_0004.pdf PDF
SK_02_HDVC_Turbine_Terrazzo_Detail-122022_0004.pdf PDF
E0_01_ELECTRICAL_LEGEND__ABBREVIATIONS____SHEET_INDEX_-_122022_0004.pdf PDF
Sol_140R3023R0003_Amd_0004.pdf PDF
E3_02_ELECTRICAL_CEILING_DEVICE_POWER_PLAN_-_122022_0004.pdf PDF
X0_300_-_WALL_FINISHES_AND_PAINT_PLAN_0003.pdf PDF
A2_41_EXHIBIT_LEVEL_-_FINISH_FLOOR_PLAN_0003.pdf PDF
E6_02_ELECTRICAL_SCHEDULES_0003.pdf PDF
E3_02_ELECTRICAL_CEILING_DEVICE_POWER_PLAN_0003.pdf PDF
A2_45_EXHIBIT_LEVEL_-_WALL_FINISH_PLAN_0003.pdf PDF
A2_46_OFFICE_LEVEL_-_WALL_FINISH_PLAN_0003.pdf PDF
Sol_140R3023R0003_Amd_0003.pdf PDF
140R3023R0003_-_Questions_and_Responses_-Amd_No__0003_0003.pdf PDF
E0_01_ELECTRICAL_LEGEND__ABBREVIATIONS____SHEET_INDEX_0003.pdf PDF
140R3023R0003_-_Questions_and_Responses_-Amd_No__0002_0002.pdf PDF
Sol_140R3023R0003_Amd_0002.pdf PDF
140R3023R0003_-_Amendment_No__0001_-_Revised_Sections_L___M_0001.pdf PDF
140R3023R0003_-_Questions_and_Responses_-Amd_No_0001_0001.pdf PDF
Attachment_9_-_Design_Drawings_0001.pdf PDF
Site_Visit_PowerPoint_Presentation_-_140R3023R0003_0001.pdf PDF
Sol_140R3023R0003_Amd_0001.pdf PDF
Final_Attendee_List_140R3023R0003_0001.pdf PDF
Attachment_3_-_Wage_Decision_No__NV20220038_-_10-21-2022.pdf PDF
Attachment_6_-_Waste_Diversion_FORM_E.pdf PDF
Attachment_5_-_Construction_Payment_Requirements.pdf PDF
Attachment_8_-_Past_Performance_Questionnaire.pdf PDF
Attachment_7_-_DI-137_Release_of_Claims.pdf PDF
_Solicitation_No__140R3023R0003_-_HD_VC_Exhibit_Level_-_Renovated_Office_Space.pdf PDF
Attachment_1_-_Specifications_-_Final_3-2022.pdf PDF
Sol_140R3023R0003.pdf PDF
Attachment_2__-_Drawings.pdf PDF
Attachment_4_-_Bond_Forms.pdf PDF
Show all 34

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

241 W. Char leston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111

LGAarchitectur e.com

AL

W

AY

S

TH

IN

K

SA

FE

TY

CA

D

FI

LE

NA

M

E

CA

D

SY

ST

EM

D

C

B

A

D

C

B

A

U.

S.

D

EP

AR

TM

EN

T

OF

T

HE

IN

TE

RI

OR

BU

RE

AU

O F

RE

CL

AM

AT

IO

N

Managing Water in the West

HO

OV

ER

D

AM

V

IS

IT

OR

C

EN

TE

R

EX

HI

BI

T

LE

VE

L A

ND

R

EN

OV

AT

ED

O

FF

IC

E

SP

AC

E

PR

OJ

EC

T

WALL SECTIONS

OFFICE

A7.03

AR

CH

IC

AD

BI

M clo ud

: b im

.lg ain c.c om

BI

M clo ud B as ic fo r A rc hic ad

5/

Ho ov er D am V isi to r C en te r E xh ibi t L ev el

DESIGNED

DRAWN

CHECKED

TECH. APPR.

APPROVED

ADMIN APPROVAL -

All dimensions and on-site conditions are to be verified by the Subcontractors before starting their work.

Report any discrepancies to the General Contractor.

Date of Issue: 03/16/22

G. PEZZI / C. LAUSSO

A. BRADSHAW

043820001PROJECT NO.:

(consultant)

(stamp)

B U

R E

A U

O F

R E

C

LA

M

AT

IO

N

B O

U

LD

E R

C

IT

Y N

V

All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.

RECLAMATION

03/16/22

A2.32

±0" EXHIBIT

LEVEL

+20' BO

CEILING

+24'

OBSERVATION

LEVEL

1'-9"

2'-3"

1'-3"

11"

7"

1' -6

2'

2' 2'

2' -6

4'

-4

6" MTL STUD @ 16" O.C.,

CONTINUOUS TO UNDERSIDE

OF DECK ABOVE

3 5/8" MTL STUD ANGLED

TO CONNECT

DIMENSIONED POINTS

INDICATED

3 5/8" HORIZONTAL MTL

STUD TIED BACK TO 6"

MTL STUD

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH,

CURVED TO FIT WALL

CURVE, NOT SEGMENTED.

A2.32

±0" EXHIBIT

LEVEL

+18'

BO CEILING

+24'

OBSERVATION

LEVEL

O P

E N

IN

G

1' -6

2'

2' 2'

2' -6

4'

-4

7' -1

1'-11/2"

71/2"

GYP BD FRAMING

BEYOND

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH,

CURVED TO FIT WALL

CURVE, NOT SEGMENTED.

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH AT

OPENING HEADERS

A2.32

1' -6

1'

1' 2'

2' 2'

-6

4' -4

7' -6

O

P E

N

IN

G

2'-3"

2'

1'-11/2"

11"

±0"

EXHIBIT

LEVEL

+20'

BO CEILING

+24'

OBSERVATION

LEVEL

GYP BD FRAMING

BEYOND

SHELVING/DISPLAY

AREA, SEE EXHIBIT

DRAWINGS

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH,

CURVED TO FIT WALL

CURVE, NOT SEGMENTED.

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH AT

DISPLAY OPENINGS,

CURVED TO MATCH WALL,

NOT SEGMENTED

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH AT

DISPLAY OPENINGS,

CURVED TO MATCH WALL,

NOT SEGMENTED

A2.32

±0" EXHIBIT

LEVEL

+18' BO

CEILING

+24' OBSERVATION

LEVEL

1' -6

2'

2' 2'

2' -6

4'

-4

3' -8

2'

8' -6

O

P E

N

IN

G

GYP BD FRAMING

BEYOND

SEATING AREA, SEE

EXHIBIT DRAWINGS

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH,

CURVED TO FIT WALL

CURVE, NOT SEGMENTED.

PROVIDE 3/8" THICK GYP.

BOARD WALL FINISH AT

OPENINGS, CURVED TO

MATCH WALL, NOT

SEGMENTED

PROVIDE 5/8" THICK GYP.

BOARD WALL FINISH AT

SEAT WALL

1 1

SCALE: 3/4" = 1'-0"1 WALL SECTION

0 1' 2' 3' SCALE: 3/4" = 1'-0"2 WALL SECTION

0 1' 2' 3' SCALE: 3/4" = 1'-0"3 WALL SECTION

0 1' 2' 3' SCALE: 3/4" = 1'-0"4 WALL SECTION

0 1' 2' 3'

ADDENDUM 2 - 12/15/22

File details come from the government source that posted it. Updated .