This document is a floor plan for the Hoover Dam Visitor Center Exhibit Level & Renovated Office Space project. The floor plan provides finishing details for the exhibit level of the visitor center, including keynotes specifying materials like terrazzo flooring, luxury vinyl tile, carpet tile in various percentages, and sealed concrete. The project involves renovating existing office space and constructing a new exhibit level. The related federal contract opportunity is solicitation number 140R3023R0003 issued by the Department of the Interior Bureau of Reclamation for the Hoover Dam Visitor Center Exhibit Level & Renovate project. The solicitation seeks contractors to complete the exhibit level and renovation work depicted in the floor plan documents.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
241 W. Char leston Blvd., Suite 107 Las Vegas, NV 89102 702.263.7111
LGA ar chitectur e.com
AL
W
AY
S
TH
IN
K
SA
FE
TY
CA
D
FI
LE
NA
M
E
CA
D
SY
ST
EM
D
C
B
A
D
C
B
A
U.
S.
D
EP
AR
TM
EN
T
OF
T
HE
IN
TE
RI
OR
BU
RE
AU
O F
RE
CL
AM
AT
IO
N
Managing Water in the West
HO
OV
ER
D
AM
V
IS
IT
OR
C
EN
TE
R
EX
HI
BI
T
LE
VE
L A
ND
R
EN
OV
AT
ED
O
FF
IC
E
SP
AC
E
PR
OJ
EC
T
EXHIBIT LEVEL - FINISH
FLOOR PLAN
OFFICE
A2.41
AR
CH
IC
AD
BI
M clo ud
: b im
.lg ain c.c om
BI
M clo ud B as ic fo r A rc hic ad
5/
Ho ov er D am V isi to r C en te r E xh ibi t L ev el
DESIGNED
DRAWN
CHECKED
TECH. APPR.
APPROVED
ADMIN APPROVAL -
All dimensions and on-site conditions are to be verified by the Subcontractors before starting their work.
Report any discrepancies to the General Contractor.
Date of Issue: 03/16/22
G. PEZZI / C. LAUSSO
A. BRADSHAW
043820001PROJECT NO.:
(consultant)
(stamp)
B U
R E
A U
O F
R E
C
LA
M
AT
IO
N
B O
U
LD
E R
C
IT
Y N
V
All Drawings, Specifications and Copies thereof furnished by the Architect are to be used only with respect to this Project and are not to be used on any other Project with the exception of one contract set for each party to the building contract. Such Documents are to be returned or suitably accounted for to the Architect on request at the completion of the Project. Any use or reproduction of this Drawing in whole or in part by any means whatsoever is strictly prohibited except with the specific written consent of LG Architects, Inc., a Nevada Corporation. Copyright © LG Architects, Inc. all rights reserved. Submission or distribution to meet official regulatory requirements or for other purposes in connection with the project in not to be construed as publication in derogation of the Architects common law Copyrights or other reserved rights.
RECLAMATION
03/16/22
U P
DN
B1.2
B1.4
2' 2'
9' -1
0"
NOTE: BUILDING CONTRACTOR
RESPONSIBLE FOR FLOORING
DEMOLITION AS INDICATED ON
SHEET A0.01, AND TERRAZZO
FLOORING IN EXHIBIT AREA.
REFER TO EXHIBIT DRAWINGS
FOR APPLICABLE FLOOR
FINISHES IN THIS AREA
NOTE: BUILDING CONTRACTOR TO
COORDINATE WITH EXHIBIT
CONTRACTOR ON FLOORING
TRANSITIONS BETWEEN EACH
CONTRACTOR'S SCOPE OF WORK
NOTE: BUILDING CONTRACTOR
RESPONSIBLE FOR FLOORING
DEMOLITION AS INDICATED ON
SHEET A0.01, AND TERRAZZO
FLOORING IN EXHIBIT AREA.
REFER TO EXHIBIT DRAWINGS
FOR APPLICABLE FLOOR
FINISHES IN THIS AREA
NOTE: EXPOSED CONCRETE
SLAB UNDERNEATH EXHIBIT
DISPLAYS, REFER TO EXHIBIT
DRAWINGS
NOTE: REFER TO SK_02
INCLUDED IN ADDENDUM 2 FOR
COLOR DETAIL IN THIS AREA.
ARTWORK TO BE PROVIDED BY
EXHIBIT DESIGNER
NOTE: BUILDING CONTRACTOR
NOT RESPONSIBLE FOR
FLOORING IN THIS PORTION OF
EXHIBIT AREA, ONLY
DEMOLITION AS INDICATED ON
SHEET A0.01
NOTE: BUILDING CONTRACTOR
NOT RESPONSIBLE FOR
FLOORING IN THIS PORTION OF
EXHIBIT AREA, ONLY
DEMOLITION AS INDICATED ON
SHEET A0.01
UP
U P
DN
SLOPE
2.75%
OPEN
TO
BELOW
WOMEN
ELECTRICAL
JANITOR
EXHIBIT
LOBBY
GALLERY
RECEPTION
TOUR
EXIT
B1
B6
B6.2
B6.4
B6.6
B6.8
B7
B7.2
B7.4
B7.6
B8
B8.2
B8.4
B8.6
B8.8
B7.8
B5.8
B5.6
B5.4
B5.2 B4.8
B4.6
B4.4
B4.2
B4
B3.8
B3.6
B3.4
B3.2
B2
B5
AB1 AB2
A2
A3
A4A5
A6
A7
A8 A1
B3
B1.6
B1.8
B2.2
B2.4
B2.6
R 2'-6"
R 2'-6"
SLOPE4.75%
VESTIBULE
MEN
FOYER
EXHIBIT
ENTRY
FLOOR FINISH KEYNOTES
ART DECO GRAPHIC INLAY TO MATCH THEATER LEVEL,
CONTRACTOR TO PROVIDE SUBMITTALS FOR APPROVAL
BY COR
INTERPRETIVE INSTALLATIONS, SEE INTERPRETIVE
DRAWINGS
EXISTING STONE TILE FINISH ON TREADS AND RISERS TO
BE REMOVED; REPLACE WITH TERRAZZO FLOORING TO
MATCH EXHIBIT LEVEL GALLERY AND EXHIBIT SPACE
REMOVE EXISTING FLOORING AND PREPARE FOR NEW
WOOD FLOORING BY OTHERS
FLOOR DIFFUSER, SEE MECHANICAL DRAWINGS
STAINLESS STEEL COLUMN WRAP, TYP
REFER TO TDS-1 ON SCHEDULE A2.50 AT TERRAZZO
FLOOR UNO, TYP
LVT-1 FLOORING TO TERMINATE AT EXISTING CASEWORK
TOE-KICK EDGE
1. NOTIFY COR OF ANY DISCREPANCIES.
2. PREPARE ALL SUBSTRATE FLOORS PER MANUFACTURER'S
DIRECTIONS
3. WHERE ADJACENT FLOOR FINISH MATERIALS VARY MORE
THAN 1/4" IN HEIGHT USE A "SCHLUTER" METAL TRANSITION
STRIP TO ACCOMMODATE ACCESSIBILITY SLOPE
GUIDELINES. ALIGN TRANSITION STRIP TO CENTER OF DOOR
PANELS
4. REFERENCE SHEET A2.50 FOR MATERIAL SCHEDULE
5. ALL ADHESIVES TO BE LOW VOC
6. FLOOR PATTERN SHOWN IS THE FLOOR PATTERN DIRECTION
FOR INSTALLATION.
7. CONTRACTOR TO PROVIDE 10% OVERAGE OF BACK STOCK
FOR OWNER OF ALL MATERIALS
8. FLOOR BOXES AND COVERS TO BE NICKEL FINISH.
FLOOR FINISH GENERAL NOTES
FLOOR FINISH PLAN LEGEND
LUXURY VINYL TILE (LVT-1)
SEALED CONCRETE (SC-1)
TERRAZZO FLOORING (TER-1), COLOR TO MATCH
TERRAZZO FLOORING AT THEATER LEVEL,
CONTRACTOR TO PROVIDE SAMPLES FOR APPROVAL
TERRAZZO FLOORING (TER-2)
CARPET TILE FLOORING (CPT-1)
CARPET TILE FLOORING (CPT-2) 80%, CARPET TILE
FLOORING (CPT-3) 10%
KEY PLAN
N
SCALE: 1/8" = 1'-0"1 EXHIBIT LEVEL FINISH PLAN
0 4' 8' 16'
NOTE: TERRAZZO FLOOR FINISH ON EXHIBIT LEVEL
IS TO BE CONTINUOUS THROUGHOUT EXCEPT WITH
APPROPRIATE TRANSITIONS BETWEEN EXHIBIT
CONTRACTOR'S AND BUILDING CONTRACTOR'S
SCOPES OF WORK.
SEE EXHIBIT DRAWINGS FOR ADDITIONAL
INFORMATION AND FINISHES WHERE APPLICABLE
ADDENDUM 2 - 12/15/22
EXHIBIT
LEVEL
NOT A
PART
File details come from the government source that posted it. Updated .