The key details are: The drawing shows the repairs needed for Frame 30 and Frame 25 of the Hercules tug, including renewal of the lower 48 inches of the floor flat plate, renewal of the riveted angle bar frame, and renewal of the deep frame flat plate. The repairs are required under a follow-on work contract for the Hercules tug at the San Francisco Maritime National Historical Site, solicited by the Department of the Interior National Park Service under Solicitation Number 140P8624Q0041. The contract requires repairing specific components of the tug's frame structure according to the detailed engineering specifications provided in the drawing.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FRAME 30
Looking FWD
CL
Lower and Upper frame steel renewal
Deep frame flat plate steel renewal
Lower 48" of floor flat plate renewal
Customer
Rules Paint
Design:
Approval:
Order no.
Drawing no.
Page
OfUSCG, ABS, DNV, etc.. Revision:
Scale:Description:
Date:
Date:Maritime Technical Services, LLC.
114 Tamal Vista, San Rafael CA. 94901
510-499-2995
WWW.MARITIMETECHSERVICES.COM
G
H
I
J
K
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
G
H
I
J
K
A
B
C
D
E
F
17 18
L
M
L
M
Steam Tug Hercules
Frame 30 NPS 7/22/24Tony G
N/A N/A TBD
No Scale 1
Lower 48" (Floor)
Riveted Angle Bar (Frame)
Boiler foundation/ saddle
Deep Frame
Existing Fillet Weld on fwd side of frame
Renew Face Plate & side angles
48"
Renew frame from C/L out to 145"
Renew deep frame flat plate from face plate out to 67"
Renew upper double
2.5 x 2.5 angle from face plate out to 93"
4'-5 3 16"
10'-013 16"
5'-7 9 16"
11'-117 8"
7'-73 4"
Renew Lug Clip longitudinal stringer
Renew frame from C/L out to 120"
Renew deep frame flat plate from face plate out to 52"
Retain S/S Faceplate
Renew upper double
2.5 x 2.5 angle from face plate out to 52"
AutoCAD SHX Text Steam Tug Hercules Frame 30
AutoCAD SHX Text Centerline looking Forward: For Illustration only(Machinery Space)
FRAME 25
Looking FWD
CL
Lower and Upper frame steel renewal
Deep frame flat plate steel renewal
Lower 48" of floor flat plate renewal requirement in original Spec 4.05.3.P
Customer
Rules Paint
Design:
Approval:
Order no.
Drawing no.
Page
OfUSCG, ABS, DNV, etc.. Revision:
Scale:Description:
Date:
Date:Maritime Technical Services, LLC.
114 Tamal Vista, San Rafael CA. 94901
510-499-2995
WWW.MARITIMETECHSERVICES.COM
G
H
I
J
K
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
G
H
I
J
K
A
B
C
D
E
F
17 18
L
M
L
M
Steam Tug Hercules
Deep Frame 25 NPS 7/22/24Tony G
N/A N/A TBD
No Scale 1
Riveted Angle Bar (Frame)
Boiler foundation/ saddle
Deep Frame
Renew frame from C/L out to 120.5"
10'-4"
Renew frame from C/L out to 120"
Renew deep frame flat plate from face plate out to existing seam outboard the logitudinal
Retain Faceplate
Renew upper double
2.5 x 2.5 angle from face plate out to 52"
10'-915 16"
3'-6"
5'-3 3 16"
AutoCAD SHX Text Steam Tug Hercules Frame 25
AutoCAD SHX Text Centerline looking Forward: For Illustration only(Machinery Space)