Attachment_15_-_Frame_Repairs_7-24-24_0004.pdf

PDF 238 KB Posted

Attached to
Follow On Work for Hercules Tugboat at Bay Ship &
Solicitation number
140P8624Q0041
Issued by

About this file

This document appears to be an engineering drawing or schematic showing the frame repairs required for the Steam Tug Hercules, which is part of a federal contract opportunity.

The key details are: The drawing shows the repairs needed for Frame 30 and Frame 25 of the Hercules tug, including renewal of the lower 48 inches of the floor flat plate, renewal of the riveted angle bar frame, and renewal of the deep frame flat plate. The repairs are required under a follow-on work contract for the Hercules tug at the San Francisco Maritime National Historical Site, solicited by the Department of the Interior National Park Service under Solicitation Number 140P8624Q0041. The contract requires repairing specific components of the tug's frame structure according to the detailed engineering specifications provided in the drawing.

View the file

Other files

File Type Posted
Sol_140P8624Q0041_Amd_0007.pdf PDF
Attachment_1_-_Price_Schedule__Revised_Dated_8_28_24_0006.xlsx XLSX spreadsheet
Sol_140P8624Q0041_Amd_0006.pdf PDF
Attachment_2_-_Statement_of_Work_Revised_8_28_24_0006.pdf PDF
Attachment_1_-_Price_Schedule_Revised_8-21-24_0005.xlsx XLSX spreadsheet
Attachment_2_-_Statement_of_Work_Revised_8_21_2024_0005.pdf PDF
Sol_140P8624Q0041_Amd_0005.pdf PDF
Attachment_2_-_Statement_of_Work_Revised_8_7_2024_0004.pdf PDF
Attachment_1_-_Price_Schedule_Revised_8_4_2024_0004.xlsx XLSX spreadsheet
Sol_140P8624Q0041_Amd_0004.pdf PDF
Attachment_14_-_Shell_Plating_Doublers_8_24_0004.pdf PDF
Sol_140P8624Q0041_Amd_0003.pdf PDF
Sol_140P8624Q0041_Amd_0002.pdf PDF
Sol_140P8624Q0041_Amd_0001.pdf PDF
Attachment_2_-_Statement_of_Work_amended_7-09-2024_0001.pdf PDF
Attachment_1_-_Price_Schedule_FINAL_amended_7-9-24_0001.xlsx XLSX spreadsheet
Sol_140P8624Q0041.pdf PDF
Attachment_6_-_Hercules_Asbestos_and_Lead_Sample_Plan___Results__2020.pdf PDF
Attachment_9_-_Hercules_Cathodic_Protection_System_Drawings_1.pdf PDF
Attachment_8_-_DDE_Drawings_20030-20A_and_20030-30A.pdf PDF
Attachment_11_-_USCGSF_-MSIB_13-01_1.pdf PDF
Attachment_2_-_Statement_of_Work.pdf PDF
Attachment_3_-_Steam_Tug_Hercules_Docking_and_Blocking_Plan_1.pdf PDF
Attachment_13_-_SCA_Wage_Determination.pdf PDF
Attachment_10_-_Hercules_Stern_Tube_and_Shaft_Drawings_1.pdf PDF
Attachment_1_-_Price_Schedule_FINAL.xlsx XLSX spreadsheet
Attachment_12_-_TOMAC_NDT_Services__Inc__Report__2001.pdf PDF
Attachment_7_-_USCG_NAVIC_7-01.pdf PDF
Attachment_5_-_Hercules_NPS_Drawings.pdf PDF
Attachment_4_-_Structural_Rehabilitation_Recommendations_-_Initial_Survey_Report__February_2021.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FRAME 30

Looking FWD

CL

Lower and Upper frame steel renewal

Deep frame flat plate steel renewal

Lower 48" of floor flat plate renewal

Customer

Rules Paint

Design:

Approval:

Order no.

Drawing no.

Page

OfUSCG, ABS, DNV, etc.. Revision:

Scale:Description:

Date:

Date:Maritime Technical Services, LLC.

114 Tamal Vista, San Rafael CA. 94901

510-499-2995

WWW.MARITIMETECHSERVICES.COM

G

H

I

J

K

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

G

H

I

J

K

A

B

C

D

E

F

17 18

L

M

L

M

Steam Tug Hercules

Frame 30 NPS 7/22/24Tony G

N/A N/A TBD

No Scale 1

Lower 48" (Floor)

Riveted Angle Bar (Frame)

Boiler foundation/ saddle

Deep Frame

Existing Fillet Weld on fwd side of frame

Renew Face Plate & side angles

48"

Renew frame from C/L out to 145"

Renew deep frame flat plate from face plate out to 67"

Renew upper double

2.5 x 2.5 angle from face plate out to 93"

4'-5 3 16"

10'-013 16"

5'-7 9 16"

11'-117 8"

7'-73 4"

Renew Lug Clip longitudinal stringer

Renew frame from C/L out to 120"

Renew deep frame flat plate from face plate out to 52"

Retain S/S Faceplate

Renew upper double

2.5 x 2.5 angle from face plate out to 52"

AutoCAD SHX Text Steam Tug Hercules Frame 30

AutoCAD SHX Text Centerline looking Forward: For Illustration only(Machinery Space)

FRAME 25

Looking FWD

CL

Lower and Upper frame steel renewal

Deep frame flat plate steel renewal

Lower 48" of floor flat plate renewal requirement in original Spec 4.05.3.P

Customer

Rules Paint

Design:

Approval:

Order no.

Drawing no.

Page

OfUSCG, ABS, DNV, etc.. Revision:

Scale:Description:

Date:

Date:Maritime Technical Services, LLC.

114 Tamal Vista, San Rafael CA. 94901

510-499-2995

WWW.MARITIMETECHSERVICES.COM

G

H

I

J

K

A

B

C

D

E

F

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

G

H

I

J

K

A

B

C

D

E

F

17 18

L

M

L

M

Steam Tug Hercules

Deep Frame 25 NPS 7/22/24Tony G

N/A N/A TBD

No Scale 1

Riveted Angle Bar (Frame)

Boiler foundation/ saddle

Deep Frame

Renew frame from C/L out to 120.5"

10'-4"

Renew frame from C/L out to 120"

Renew deep frame flat plate from face plate out to existing seam outboard the logitudinal

Retain Faceplate

Renew upper double

2.5 x 2.5 angle from face plate out to 52"

10'-915 16"

3'-6"

5'-3 3 16"

AutoCAD SHX Text Steam Tug Hercules Frame 25

AutoCAD SHX Text Centerline looking Forward: For Illustration only(Machinery Space)

Sheets and Views
Frame Repairs 7-17-24-Frame 30
Frame Repairs 7-17-24-Frame 25

File details come from the government source that posted it. Updated .