This package includes construction drawings and details for storm window installations at Yellowstone National Park buildings, along with the related federal contract solicitation. The solicitation seeks proposals to rehabilitate the exteriors of historic buildings 4 through 33 at Fort Yellowstone, as outlined in the construction drawings. Key scope items include installing fixed and operable wood storm windows with insulating glass and integrated insect screens. The drawings provide dimensions, materials, and installation specifications for various window configurations across the buildings. Proposals are due by January 20, 2023 and the contract is a small business set-aside awarded under solicitation number 140P2023R0170 by the National Park Service on behalf of Yellowstone National Park. The period of performance and total budget are not specified.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(E) WINDOW TRIM
FIXED UPPER STORM
SASH
STORM MID-RAIL TO
ALIGN WITH WINDOW
MID-RAIL BEYOND
FASTEN UPPER SASH W/
SCREWS OR TURN
BUTTONS, TBD BY NPS
OPERABLE, PRESSURE-
FITTED INSECT SCREEN
W/ C-CHANNEL TRACK
INT. EXT.
ELEVATIONSECTION
GRILL PATTERN TO
MATCH HISTORIC
WINDOWS BEYOND;
BOTH SASHES
WEATHER STRIP AROUND
FRAMES, ALL SIDES
INSULATING GLASS
CAM HANDLE LOCK
& STRIKE, QTY. 2
OPERABLE LOWER
STORM SASH
STORM SASH FRAME
VARIES
V A R
IE
S
OPT: METAL L-ANGLE
SUPPORT, EA. SIDE
1 1/4"TYP.
AWNING HINGE
VARIES
A1
A1
A1
FURRING STRIP
WRB-3
REINSTALL (E) RESTORED OR
(N) WOOD SIDING
REINSTALL (E) RESTORED OR
(N) TRIM ALIGN WITH SIDING
SHEET METAL HEAD FLASHING
INTERIOR EXTERIOR
FLEXIBLE FLASHING
SEALANT TYPE A-1
WITH BACKER ROD
LIQUID APPLIED FLASHING
SECTION
4"
1"
DRIP
3/4" X 1-3/4" SS TURN
BUTTON - (2) PER TOP RAIL
5/4" X 3" FIXED WOOD STORM
SASH, PAINT TO MATCH (E) WINDOW
INSULATING GLASS
5/4" (FACE) SASH FRAME AND STOP WITH
KERFED-IN WEATHERSTIPPING, ALL SIDES
A L
IG
N
FURRING STRIP
WRB-3
REINSTALL (E) RESTORED OR
(N) WOOD SIDING
REINSTALL (E) RESTORED OR
(N) TRIM ALIGN WITH SIDING
SHEET METAL HEAD FLASHING
INTERIOR EXTERIOR
FLEXIBLE FLASHING
SEALANT A-1 WITH
BACKER ROD
LIQUID APPLIED
FLASHING
SECTION
3/4" X 1-3/4" SS TURN
BUTTON - (2) PER TOP RAIL
5/4" X 3" FIXED WOOD STORM
SASH, PAINT TO MATCH (E) WINDOW
INSULATING GLASS
5/4" (FACE) SASH FRAME AND STOP WITH
KERFED-IN WEATHERSTIPPING, ALL SIDES
A L
IG
N
INTERIOR EXTERIOR
FURRING STRIP
WRB-3
FLEXIBLE FLASHING
SEALANT TYPE A WITH
BACKER ROD
LIQUID APPLIED
FLASHING
REINSTALL (E) RESTORED OR
(N) WOOD SIDING
M
IN
M
IN
5/4" X 3" OPERABLE WOOD
STORM SASH, PAINT TO
MATCH (E) WINDOW
INSECT SCREEN (SHOWN PARTIALLY OPEN)
CAM HANDLE LOCK & STRIKE, QTY. 2
5/4" (FACE) SASH FRAME AND STOP WITH
KERFED-IN WEATHERSTRIPPING, ALL SIDES
INTERIOR EXTERIOR
2X2 WOOD NAILER,
PRIME PAINT ALL SIDES
SEALANT TYPE A
WRB-2
WRB-1
FLASHING CAP
WRB-2 VERTICAL UP
TO UNDERSIDE OF SILL
12"
5/4" X 3" OPERABLE WOOD STORM
SASH, PAINT TO MATCH (E) WINDOW
INSECT SCREEN (SHOWN PARTIALLY
OPEN)
CAM HANDLE LOCK & STRIKE, QTY. 2
5/4" (FACE) SASH FRAME AND STOP
WITH KERFED-IN WEATHERSTRIPPING,
ALL SIDES
INTERIOR EXTERIOR
OPERABLE LOWER STORM SASH ON AWNING
HINGES AT JAMBS, PAINT TO MATCH (E) WINDOW
INSULATING GLASS
INSULTATED GLASS
FIXED STORM SASH, PAINT
TO MATCH (E) WINDOW
KERFED-IN WEATHERSTRIPPING
AT MEETING RAIL, TYP
INSECT SCREEN
INTERIOR
EXTERIOR
FURRING STRIP
WRB-3
REINSTALL (E) RESTORED
OR (N) WOOD SIDING
FLEXIBLE FLASHING
ELASTOMERIC SEALANT
WITH BACKER ROD
LIQUID APPLIED FLASHING
(E) WINDOW FRAME
5/4" X 3" OPERABLE
WOOD STORM SASH,
PAINT TO MATCH (E)
WINDOW
INSECT SCREEN
KERFED-IN
WEATHERSTRIPPING
ALIGN
AWNING HINGE
CONCEALED AT RABBET
FURRING STRIP
WRB-3
REINSTALL (E) RESTORED OR
(N) WOOD SHINGLES, TYP
SHEET METAL HEAD FLASHING
INTERIOR EXTERIOR
WRB-2
ELASTOMERIC SEALANT
WITH BACKER ROD
LIQUID APPLIED
FLASHING
SECTION
3/4" X 1-3/4" SS TURN
BUTTON - (2) PER TOP RAIL
5/4" X 3" FIXED WOOD STORM
SASH, PAINT TO MATCH (E) WINDOW
INSULATING GLASS
5/4" (FACE) SASH FRAME AND STOP WITH
KERFED-IN WEATHERSTIPPING, ALL SIDES
A L
IG
N
DRAINAGE MAT
WRB-3
(N) WOOD SHINGLES, TYP
SHEET METAL
FLASHING
INTERIOR EXTERIOR
FLEXIBLE FLASHING
ELASTOMERIC SEALANT
WITH BACKER ROD
LIQUID APPLIED FLASHING
SECTION
DRAINAGE MAT
6"
4"
3/4" X 1-3/4" SS TURN
BUTTON - (2) PER TOP RAIL -
COMPRESS WEATHERSTRIPPING
5/4" X 3" FIXED WOOD STORM
SASH, PAINT TO MATCH (E) WINDOW
INSULATING GLASS
5/4" (FACE) SASH FRAME AND STOP WITH
KERFED-IN WEATHERSTIPPING, ALL SIDES
A L
IG
N
BASIS OF DESIGN
1. WEATHER STRIPPING: ASSA ABLOY - PEMKO PERIMETER
GASKETING; S105.
2. INSULATING GLASS: OLDCASTLE BUILIDNG ENVELOPE -
INSULATING GLASS, 1/2" OVERALL THICKNESS (1/8" GLASS
W/ 1/4" AIRSPACE), CLEAR SPACER.
3. AWNING HINGE: TRUTH HARDWRE - PROJECTED AWNING,
HEAVY-DUTY, 4-BAR HINGE (3011SS SERIES);
COUNTERBALANCED.
4. INSECT SCREEN: WALLSIDE WINDOWS, OR EQUAL -
ALUMINUM HALF SCREEN OPERATION.
5. CAM HANDLE LOCK: TRUTH HARDWARE - 25 SERIES
TRIMLINE; STRIKE PLATE 30569.
6. TURNBUTTONS (TBD BY NPS): KILIAN HARDWARD - SS
TURNBUTTON-TW.
INTERIOR EXTERIOR
FURRING STRIP
WRB-3
REINSTALL (E) RESTORED OR
(N) WOOD SIDING
WRB-2
ELASTOMERIC SEALANT
WITH BACKER ROD
LIQUID APPLIED
FLASHING
5/4" X 3" OPERABLE WOOD
STORM SASH, PAINT TO
MATCH (E) WINDOW
INSECT SCREEN (SHOWN PARTIALLY
OPEN)
CAM HANDLE LOCK & STRIKE,
QTY. 2
5/4" (FACE) SASH FRAME AND
STOP WITH KERFED-IN
WEATHERSTRIPPING, ALL SIDES
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
PMIS NO.
SHEET
DRAWING NO.
OF
REHABILITATE EXTERIORS OF
HISTORIC FORT YELLOWSTONE BUILDINGS
YELLOWSTONE NATIONAL PARK
DRAWN:
173853
A u to d e s k
D o c s T
N P S
Y e ll
E x te ri o r R e h a b T
N P S
Y E L L
E x te ri o r R e h a b .r vt
STORM WINDOW DETAILS
(ADDENDUM #001)
TM
HC
HC/TM
A1 307127
11/09/2023 2
CONSTRUCTION DRAWINGS
NOT TO SCALE
STORM SASH
SCALE OF INCHES
SCALE
3 0 66
F
SCALE F
TYPICAL WINDOW HEAD AT WALL
SCALE F
WINDOW HEAD AT HEAD TRIM
SCALE F
WINDOW SILL AT WALL
SCALE F
WINDOW SILL AT HEAD WALL
SCALE F
STORM SASH MEETING RAIL
SCALE F
WINDOW JAMB - LOWER SASH
SCALE F
WINDOW HEAD AT CURVED EAVE
SCALE F
WINDOW HEAD AT ANGLED EAVE
SCALE F
WINDOW SILL AT SIDING TRANSITION
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
PMIS NO.
SHEET
DRAWING NO.
OF
REHABILITATE EXTERIORS OF
HISTORIC FORT YELLOWSTONE BUILDINGS
YELLOWSTONE NATIONAL PARK
DRAWN:
173853
A u to d e s k
D o c s T
N P S
Y e ll
E x te ri o r R e h a b T
N P S
Y E L L
E x te ri o r R e h a b .r vt
VIEW # CONVERSION
TABLE (ADDENDUM #001)
TM
HC
HC/TM
A2 307127
11/09/2023 2
CONSTRUCTION DRAWINGS
09-A806 11 WINDOW JAMB - LOWER SASH 3 NO CHANGE
09-A806 10 STORM SASH MEETING RAIL 2 NO CHANGE
09-A806 9 STORM SASH 1 NO CHANGE
09-A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
09-A806 7 WINDOW SILL AT WALL 8 NO CHANGE
09-A806 4 WINDOW HEAD AT HEAD TRIM 7 NO CHANGE
09-A806 3 WINDOW HEAD AT ANGLED EAVE 5 NO CHANGE
09-A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDING 9
08-A806 9 STORM SASH 1 NO CHANGE
08-A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
08-A806 7 WINDOW SILL AT WALL 8 NO CHANGE
08-A806 5 WINDOW HEAD AT CURVED EAVE 4 NO CHANGE
08-A806 4 WINDOW JAMB - LOWER SASH 3 NO CHANGE
08-A806 3 STORM SASH MEETING RAIL 2 NO CHANGE
08-A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDING 8
07-A806 10 WINDOW JAMB - LOWER SASH 3 NO CHANGE
07-A806 9 STORM SASH 1 NO CHANGE
07-A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
07-A806 7 WINDOW SILL AT WALL 8 NO CHANGE
07-A806 4 WINDOW HEAD AT HEAD TRIM 7 NO CHANGE
07-A806 3 STORM SASH MEETING RAIL 2 NO CHANGE
07-A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDING 7
A806 11 WINDOW JAMB - LOWER SASH 3 NO CHANGE
A806 10 STORM SASH MEETING RAIL 2 NO CHANGE
A806 9 STORM SASH 1 NO CHANGE
A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
A806 7 WINDOW SILL AT WALL 8 NO CHANGE
A806 4 WINDOW HEAD AT HEAD TRIM 7 NO CHANGE
A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDINGS 4-6
VIEW # CONVERSION TABLES
83-A901 2 STORM SASH MEETING RAIL 2 NO CHANGE
83-A901 1 STORM SASH 1 NO CHANGE
83-A801 10 WINDOW SILL AT WALL 8 NO CHANGE
83-A801 9 WINDOW HEAD AT HEAD TRIM 9 NO CHANGE
83-A801 7 WINDOW SILL AT SIDING TRANSITION 10 NO CHANGE
83-A801 6 WINDOW JAMB - LOWER SASH 3 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDING 83
A806 11 WINDOW JAMB - LOWER SASH 3 NO CHANGE
A806 9 STORM SASH 1 NO CHANGE
A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
A806 7 WINDOW SILL AT WALL 8 NO CHANGE
A806 5 STORM SASH MEETING RAIL 2 NO CHANGE
A806 4 WINDOW HEAD AT HEAD TRIM 7 NO CHANGE
A806 3 WINDOW HEAD AT ANGLED EAVE 5 NO CHANGE
A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDINGS 31-33
30-A806 11 WINDOW JAMB - LOWER SASH 3 NO CHANGE
30-A806 10 STORM SASH MEETING RAIL 2 NO CHANGE
30-A806 9 STORM SASH 1 NO CHANGE
30-A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
30-A806 7 WINDOW SILL AT WALL 8 NO CHANGE
30-A806 4 WINDOW HEAD AT HEAD TRIM 7 NO CHANGE
30-A806 3 WINDOW HEAD AT ANGLED EAVE 5 NO CHANGE
30-A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDING 30
14-A806 11 WINDOW JAMB - LOWER SASH 3 NO CHANGE
14-A806 10 STORM SASH MEETING RAIL 2 NO CHANGE
14-A806 9 STORM SASH 1 NO CHANGE
14-A806 7 WINDOW SILL AT WALL 8 NO CHANGE
14-A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDING 14
A806 11 WINDOW JAMB - LOWER SASH 3 NO CHANGE
A806 10 STORM SASH MEETING RAIL 2 NO CHANGE
A806 9 STORM SASH 1 NO CHANGE
A806 8 WINDOW SILL AT HEAD WALL 9 NO CHANGE
A806 7 WINDOW SILL AT WALL 8 NO CHANGE
A806 5 WINDOW HEAD AT CURVED EAVE 4 NO CHANGE
A806 4 WINDOW HEAD AT HEAD TRIM 7 NO CHANGE
A806 2 TYPICAL WINDOW HEAD AT WALL 6 NO CHANGE
SHEET # VIEW # VIEW NAME VIEW # VIEW NAME
5/2/2023 ADDENDUM #001 - 11/09/2023
BUILDINGS 10-12
VIEW # CONVERSION TABLES
| Sheets |
| A1 - STORM WINDOW DETAILS (ADDENDUM #001) |
| A2 - VIEW # CONVERSION TABLE (ADDENDUM #001) |
File details come from the government source that posted it. Updated .