This solicitation package includes specifications for the construction of a new visitor center building at the Bureau of Land Management's Little Sahara Recreation Area in Utah. The project scope encompasses construction of a 3,100 square foot wood-framed structure with concrete masonry exterior, along with associated site work including utilities installation, landscaping, and a photovoltaic system. The package also specifies demolition of the existing 2,800 square foot visitor center building and related site elements. The anticipated period of performance is May through December 2021. This procurement is set aside exclusively for small businesses and Davis-Bacon wage rates apply. Interested vendors should monitor the listed websites for solicitation documents and amendments.

View the file

Other files

File Type Posted
Sol_140L5721R0001_Amd_0006.pdf PDF
140L5721R0001 - Little Sahara VC Construction - Sol Sections B - M - Amendment 6_0006.pdf PDF
Sol_140L5721R0001_Amd_0005.pdf PDF
Sol_140L5721R0001_Amd_0004.pdf PDF
Little Sahara Visitor Center - Photos of Existing Building_0004.pdf PDF
088000 - Glazing_0004.doc DOC document
Questions and Answers Spreadsheet - Amendment 4_0004.pdf PDF
Added Drawing Sheet E104_0004.pdf PDF
Revised Drawing Sheets G002-AG501_0004.pdf PDF
Existing Visitor Center Floor Plan_0003.jpg JPG image
Little Sahara Visitor Center Statement of Work - Revised_0003.pdf PDF
271000 - Structured Cabling_0003.pdf PDF
013200 - Construction Progress Documentation_0003.pdf PDF
Little Sahara Visitor Center Pricing Worksheet - Revised_0003.pdf PDF
Site Visit Attendance Roster_0003.pdf PDF
Existing Visitor Center Elevations 1_0003.jpg JPG image
012000 - Unit Prices and Schedule of Values_0003.pdf PDF
Lay Down - Storage Area_0003.pdf PDF
Temporary Construction Fencing_0003.pdf PDF
L2047 Little Sahara Visitor Center ACM Report_0003.pdf PDF
E-101_Revised_2021-03-26-E-101_0003.pdf PDF
Questions and Answers Spreadsheet_0003.pdf PDF
140L5721R0001 - Little Sahara VC Construction - Sol Sections B - M - Amendment 3_0003.pdf PDF
Sol_140L5721R0001_Amd_0003.pdf PDF
Existing Visitor Center Elevations 2_0003.jpg JPG image
140L5721R0001 - Little Sahara VC Construction - Sol Sections B - M - Amendment 2_0002.pdf PDF
Sol_140L5721R0001_Amd_0002.pdf PDF
Sol_140L5721R0001_Amd_0001.pdf PDF
Little Sahara Visitor Center Pricing Worksheet.pdf PDF
Little Sahara Drawings.pdf PDF
Sol_140L5721R0001.pdf PDF
Little Sahara Visitor Center Statement of Work.pdf PDF
Little Sahara Geotech Report.pdf PDF
Davis Bacon Wage Determination UT20210084.pdf PDF
Little Sahara Specifications.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Copyright 2004 by The American Institute of Architects (AIA)

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

SECTION 101400 - SIGNAGE

This Section uses the term "Architect." Change this term to match that used to identify the design professional as defined in the General and Supplementary Conditions.

Verify that Section titles referenced in this Section are correct for this Project's Specifications; Section titles may have changed.

PART 1 - GENERAL

1.1 RELATED DOCUMENTS

A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this Section.

1.2 SUMMARY

A. This Section includes the following:

Adjust list below to suit Project.

1. Accessible restroom signage.

2. Office and room identification signage.

3. Wayfinding signage

1.3 DEFINITIONS

Retain this Article if term in paragraph below remains after this Section has been edited.

A. ADA-ABA Accessibility Guidelines: U.S. Architectural & Transportation Barriers Compliance Board's "Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Architectural Barriers Act (ABA) Accessibility Guidelines."

1.4 SUBMITTALS

A. Product Data: For each type of product indicated.

Retain first paragraph and subparagraphs below. Add requirements for different sign types.

B. Product Information for Initial Selection: Manufacturer's catalog cut sheets showing the full range of colors available for the following:

Delete materials in list below if not required.

1. Aluminum.

2. Acrylic sheet.

3. Polycarbonate sheet.

4. Fiberglass sheet.

C. Maintenance Data: For signs to include in maintenance manuals.

1.5 QUALITY ASSURANCE

A. Fabricator Qualifications: Shop that employs skilled workers who custom-fabricate products similar to those required for this Project and whose products have a record of successful in-service performance.

B. Source Limitations for Signs: Obtain each sign type indicated from one source from a single manufacturer.

Signage required to be accessible to people with disabilities must comply with requirements in ADA-ABA Accessibility Guidelines and with requirements of authorities having jurisdiction, whichever are more stringent. Verify local requirements and insert additional requirements below.

C. Regulatory Requirements: Comply with applicable provisions in ADA-ABA Accessibility Guidelines and ICC/ANSI A117.1.

1.6 PROJECT CONDITIONS

A. Field Measurements: Verify recess openings by field measurements before fabrication and indicate measurements on Shop Drawings.

PART 2 - PRODUCTS

2.1 PANEL SIGNS

Delete this Article if no panel signs.

See Editing Instruction No. 1 in the Evaluations for cautions about naming manufacturers and products. Retain one of first three paragraphs and list of manufacturers below. See Division 1 Section "Product Requirements."

A. Manufacturers: Subject to compliance with requirements, provide products by one of the following:

Manufacturers listed below use one or more of graphic processes specified. Revise list to suit Project.

1. ACE Sign Systems, Inc.

2. Advance Corporation; Braille-Tac Division.

3. Allen Industries Architectural Signage.

4. Allenite Signs; Allen Marking Products, Inc.

5. APCO Graphics, Inc.

6. ASI-Modulex, Inc.

7. Best Sign Systems Inc.

8. Bunting Graphics, Inc.

9. Fossil Industries, Inc.

10. Gemini Incorporated.

11. Grimco, Inc.

12. Innerface Sign Systems, Inc.

13. InPro Corporation

14. Matthews International Corporation; Bronze Division.

15. Mills Manufacturing Company.

16. Mohawk Sign Systems.

17. Nelson-Harkins Industries.

18. Seton Identification Products.

19. Signature Signs, Incorporated.

20. Supersine Company.

B. Interior Panel Signs: Provide smooth sign panel surfaces constructed to remain flat under installed conditions within a tolerance of plus or minus 1/16 inch measured diagonally from corner to corner, complying with the following requirements:

Revise subparagraphs and associated subparagraphs below to suit Project.

Select materials from first 10 subparagraphs below.

1. Acrylic Sheet: 0.060 inch thick.

2. Edge Condition: Bullnose.

3. Corner Condition: Rounded to ½ inch radius.

4. Mounting: Unframed.

a. Wall mounted with two-face tape.

5. Color: As selected by Architect from manufacturer's full range.

6. Tactile Characters: Characters and Grade 2 Braille raised 1/32 inch above surface with contrasting colors.

C. Tactile and Braille Sign: Manufacturer's standard process for producing text and symbols complying with ADA-ABA Accessibility Guidelines and with ICC/ANSI A117.1. Text shall be accompanied by Grade 2 Braille. Produce precisely formed characters with square-cut edges free from burrs and cut marks; Braille dots with domed or rounded shape.

1. Panel Material: Opaque acrylic sheet.

2. Raised-Copy Thickness: Not less than 1/32 inch.

D. Panel Sign Schedule:

Copy subparagraph and associated subparagraphs below for each sign type and insert applicable requirements.

1. Sign Type: Accessible Restroom Sign:

a. Manufacturer’s standard ADA/ABA compliant sign for each restroom.

b. Quantity: 2

2.2 FINISHES, GENERAL

A. Appearance of Finished Work: Variations in appearance of abutting or adjacent pieces are acceptable if they are within one-half of the range of approved Samples. Noticeable variations in the same piece are not acceptable. Variations in appearance of other components are acceptable if they are within the range of approved Samples and are assembled or installed to minimize contrast.

2.3 ACRYLIC SHEET FINISHES

A. Colored Coatings for Acrylic Sheet: For copy and background colors, provide colored coatings, including inks, dyes, and paints, that are recommended by acrylic manufacturers for optimum adherence to acrylic surface and that are UV and water resistant for five years for application intended.

PART 3 - EXECUTION

3.1 EXAMINATION

A. Examine substrates, areas, and conditions, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of work.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.2 INSTALLATION

A. Locate signs and accessories where indicated, using mounting methods of types described and complying with manufacturer's written instructions.

1. Install signs level, plumb, and at heights indicated, with sign surfaces free of distortion and other defects in appearance.

Revise subparagraph below to suit Project. Delete if all locations are scheduled or indicated on Drawings.

2. Interior Wall Signs: Install signs on walls adjacent to latch side of door where applicable. Where not indicated or possible, such as double doors, install signs on nearest adjacent walls. Locate to allow approach within 3 inches of sign without encountering protruding objects or standing within swing of door.

Delete paragraph and subparagraphs below if wall-mounted signs are not included. If only one mounting method is required, combine paragraph with applicable subparagraph.

B. Wall-Mounted Signs: Comply with sign manufacturer's written instructions except where more stringent requirements apply.

Select appropriate mounting methods from subparagraphs below.

1. Two-Face Tape: Mount signs to smooth, nonporous surfaces. Do not use this method for vinyl-covered or rough surfaces.

3.3 CLEANING AND PROTECTION

A. After installation, clean soiled sign surfaces according to manufacturer's written instructions. Protect signs from damage until acceptance by Owner.

END OF SECTION 101400

MARCH 2021-ADDENDUM #01

SIGNAGE

LITTLE SAHARA VISITOR CENTER REPLACEMENT

101400 - 1