Revised Drawing Sheets G002-AG501_0004.pdf
PDF 4 MB Posted
- Attached to
- LITTLE SAHARA VISITOR CENTER CONSTRUCTION & DEMO
- Solicitation number
- 140L5721R0001
About this file
This solicitation is for the construction of a new 3,100 square foot visitor center at the Little Sahara Recreation Area in Juab County, Utah. The contractor will be responsible for providing and constructing the building, interior finishes, plumbing, mechanical, electrical and site work including installation of storm water collection systems, new utilities, sanitary sewer piping to a septic system, site landscaping and a photovoltaic system. The project also includes demolition of the existing 2,800 square foot visitor center building, slab, foundation and portions of site improvements. The period of performance is from May to December 2021. This project is set aside for small businesses and Davis Bacon Act wage determinations apply. Interested vendors must register in the System for Award Management to be eligible for award. A pre-proposal site visit will be held and the solicitation can be found on the listed websites.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :3
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
IN
D E X
S H E E T
G002
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
A u th o r
C h e c k e r
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
DRAWING INDEX
STRUCTURAL
S001 GENERAL STRUCTURAL NOTES
S002 STRUCTURAL ABBREVIATIONS & LEGEND
S101 FOUNDATION LAYOUT
S102 TRUSS LAYOUT
S201 SECTION
S501 TYPICAL STRUCTURAL DETAILS
S502 DETAILS
S503 DETAILS
S504 DETAILS
S505 DETAILS
S506 DETAILS
S507 DETAILS
S508 DETAILS
MECHANICAL
M001 MECHANICAL LEGEND
M101 HVAC PLAN
M102 HVAC PIPING AND CONTROL WIRING PLAN
M103 MECHANICAL ROOM PLAN
M104 HVAC ZONES AND CONTROL SEQUENCE
M301 HVAC SECTION VIEWS
M302 HVAC SECTION VIEWS
M501 HVAC DETAILS
M502 HVAC DETAILS
M503 HVAC DETAILS
M601 HVAC SCHEDULE
PLUMBING
P101 PLUMBING & UTILITY PLAN
P102 PLUMBING & UTILITY ISOMETRIC
P103 SANITARY SEWER SYSTEM PLAN
P104 SANITARY SEWER SYSTEM ISOMETRIC
P501 DETAILS
P601 FIXTURE SCHEDULE
ELECTRICAL
E001 ELECTRICAL ABBREVIATIONS, LEGEND, AND
GENERAL NOTES
E002 ELECTRICAL SINGLE LINE DIAGRAM
E101 ELECTRICAL SITE PLAN
E102 ELECTRICAL POWER AND TELECOM PLAN
E103 ELECTRICAL LIGHTING PLAN
E401 PHOTOVOLTAIC SYSTEM PLAN
E501 ELECTRICAL DETAILS
E502 ELECTRICAL DETAILS
E601 ELECTRICAL PANEL AND LIGHTING SCHEDULES
DRAWING INDEX
GENERAL
G001 COVER SHEET
G002 INDEX SHEET
CIVIL
C001 CIVIL NOTES & LEGEND
C101 EXISTING SITE PLAN
C102 DEMOLITION PLAN - PHASE 1 (PRIOR TO VISITOR
CENTER CONSTRUCTION)
C103 DEMOLITION PLAN - PHASE 2 (AFTER VISITOR
CENTER CONSTRUCTION)
C104 SITE IMPROVEMENT AND DRAINAGE PLAN
C105 SITE UTILITY PLAN
C501 DETAILS
C502 DETAILS
C503 DETAILS
C504 DETAILS
C505 DETAILS
C506 DETAILS
LANDSCAPE
L101 SITE LANDSCAPE PLAN
ARCHITECTURAL
GI-002 ABBREVIATIONS
GI-003 GENERAL INFORMATION
GI-101 LIFE SAFETY PLAN
GI-501 WALL, ROOF, CEILING & FLOOR ASSEMBLY TYPES
GI-701 ACCESSIBILITY COMPLIANCE
GI-702 ACCESSIBILITY COMPLIANCE
AE101 FLOOR PLAN
AE121 ROOF PLAN
AE110 DIMENSION PLAN
AE151 REFLECTED CEILING PLAN
AE202 BUILDING ELEVATIONS
AE251 INTERIOR ELEVATIONS
AE301 BUILDING SECTIONS
AE351 WALL SECTIONS
AE501 PLAN DETAILS
AE511 SECTION DETAILS
AE601 DOOR/WINDOW TYPES AND SCHEDULES
AE610 DOOR AND WINDOW DETAILS
AE401 ENLARGED PLANS
AE201 BUILDING ELEVATIONS
AE302 BUILDING SECTIONS
AE252 INTERIOR ELEVATIONS
AE512 SECTION DETAILS
AF101 FINISH FLOOR PLAN
AG501 SIGNAGE DETAILS
AG101 SIGNAGE PLAN
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
1 2 3 4
A
B
C
D
MED
UNIT
TOILET
MECHANICAL
BREAKROOM
STORAGE
MED.
STORAGE
WOMEN'S
TOILET
MEN'S
TOILET
RECEPTION
CONFERENCE
CASH
ROOM
LOBBY
HALL
WORK
AREA
E
AE201
A
E
AE201
A
E
AE251 1
AE302
AE302
STORAGE
VESTIBULE
AE301
AE301
AE301
AE301
AE302
AE302
NS32A
N S
A
NS32A
NS62A
NS62A
NS32A
NS32A
NS31A
N S
A
N S
A
NS31A
N S
A
112A
111A
A
HALL
F
F
B
B
B
B
BBB
B
B
B
D
D
D
AE2514
AE251 3
AE251
AE252 1
AE252
AE252
N S
A
NS32A F
F
7.85
12.02
12.02
12.02
12.02
12.02
22.10
NS31A
NS32A
N S
A
N S
A N S
A
N S
A
NS31A
N S
A
N S
A
10.34
N S
A
NS32A
AE511
AE511
AE511
22.01
22.01
22.01
22.01
A
JANITOR
22.01
AE501
7.85
7.85
A
E
E
E
E
A
10.30
10.30
6.53
5.62
5.62
10.16
OH
OH
AE610
10.49
10.72
AE351
AE351
AE351
AE351
AE511
10.46
7.85
5.62
5.62
COMM.
113A 113A
EM83
EM83
E M
E M
E M
EM83
EM83
EM83
N S
A
N S
A
N S
A
NS32A
AE401
AE401
NS32A
NS32A
22.02
6.38
AE512
AE512
10.74
E M
GENERAL NOTES - FLOOR PLAN
1. DIMENSIONS ARE TO THE FACE OF STUD OR GRIDLINE. IF
WALL IS EXISTING, DIMENSION IS TO FACE OF WALL.
"CLEAR" DIMENSIONS ARE FROM FACE OF FINISH TO
FACE OF FINISH.
2. REFER TO G SERIES SHEETS FOR ACCESSIBILITY
REQUIREMENTS AND ASSEMBLY TYPES.
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :2
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
F L O O R
P L A N
AE101
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
S C
K U
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
22 78
N
0' 2'1'1' 3' 4' 5' 6' 7'AE101
FLOOR PLAN OVERALL1
KEYNOTE LEGEND
5.62 CANOPY ABOVE.
6.38 PROVIDE 3/4" THICK, 8'-0" HIGH FIRE TREATED PLYWOOD ON
N, S, AND W WALLS.
6.53 STAINLESS STEEL WRITING SHELF MOUNTED ON BRACKETS.
SEE SPEC.
7.85 METAL DOWNSPOUT.
10.16 MOP RACK AND SHELF TO BE INSTALLED ALONG WALL.
COORDINATE WITH OWNER ON LOCATION.
10.30 FIRE EXTINGUISHER IN SEMI-RECESSED CABINET. SEE
SPEC.
10.34 REFRIGERATOR. NIC.
10.46 ROLLER WINDOW SHADES TYP. ALL EXTERIOR WINDOWS.
REFER TO ACCESSORY SCHEDULE. SEE SPECS.
10.49 WHITEBOARD.
10.72 WALL MOUNTED FLAT SCREEN T.V.
10.74 BABY CHANGING STATION.
12.02 FURNISHING BY OWNER.
22.01 FLOOR DRAIN. SET DRAIN 1/2" DOWN FROM TOP OF SLAB.
SLOPE FLOOR TO LEVEL AT 12" AWAY ON FOUR SIDES.
22.02 MOP SINK/BASIN.
22.10 DRINKING FOUNTAIN.
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
MAIN LEVEL
0' - 0"
T.O. HIGH WALL
18' - 5"
AE302
AE302
T.O. LOW WALL
11' - 4"
AE302
AE302
8.168.07
7.59
B
7.86
R2
9.13
7.85
9.13
BB
26.06
26.06
C C C C
7.99
5.49
E
7.85
5.49
5.49
4.11
4.124.10
4.10
T.O. ENTRY WALL
14' - 8"
CCCCC CCC
3.06 3.07
7.87
MAX, TYP.
6' - 8"
MAIN LEVEL
0' - 0"
T.O. HIGH WALL
18' - 5"
1 2 3 41
AE302
T.O. LOW WALL
11' - 4"
AE302
7.59
8.07
R2
7.86
7.86
26.06
26.06
5.59
5.59
A R E
C E
S S
R E
C E
S S
A
26.32
5.49
4.10
4.11
4.10
4.12
7.85
T.O. ENTRY WALL
14' - 8"
6.53
RECESS
4' - 0"6' - 8"
RECESS
4' - 0"3' - 4" 4' - 8"
RECESS
4' - 0"
7.87
7.87 7.87
10.02
10.03
ELEVATION GENERAL NOTES
1. COORDINATE GRADING SHOWN ON ELEVATIONS WITH
CIVIL.
2. FOR WALL TYPES SEE WALL SECTIONS, FLOOR PLANS,
AND ASSEMBLY TYPES FOR LOCATIONS AND
CONSTRUCTION.
3. PROVIDE GUTTERS AND DOWNSPOUTS WITH HEAT
CABLING, INCLUDING REQUIRED ELECTRICAL SERVICE
AND CONTROLS. COORDINATE WITH FEATURES
INDICATED ON ROOF PLAN.
4. SEE ROOF PLAN FOR LOCATIONS AND EXTENTS OF
SNOW CLIPS AND SNOW GUARDS IN COLD CLIMATES.
COORDINATE WITH ROOF PLAN.
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :4
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
B U
IL
D
IN
G
E L E V A T
IO
N S
AE201
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
S C
K U
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
26 78
0' 2'1'1' 3' 4' 5' 6' 7'AE201
BUILDING ELEVATION - NORTH1
0' 2'1'1' 3' 4' 5' 6' 7'AE201
BUILDING ELEVATION - SOUTH2
KEYNOTE LEGEND
3.06 CONTROL JOINT.
3.07 EXPANSION JOINT.
4.10 CMU BLOCK.
4.11 HONED CMU ACCENT STRIP.
4.12 SPLIT FACE CMU WAINSCOT.
5.49 CANOPY.
5.59 SHADE STRUCTURE. REFER TO STRUCTURAL.
6.53 STAINLESS STEEL WRITING SHELF MOUNTED ON
BRACKETS. SEE SPEC.
7.59 STANDING SEAM ROOF. SEE ROOF TYPES.
7.85 METAL DOWNSPOUT.
7.86 SHEET METAL FASCIA PANEL.
7.87 METAL GUTTER SYSTEM.
7.99 4" HEAVY DUTY EIFS SYSTEM, SEE SPECS.
8.07 DOOR. SEE DOOR SCHEDULE.
8.16 WINDOW. SEE WINDOW TYPES.
9.13 METAL PANEL SOFFIT.
10.02 1/4" UNCOATED STEEL PANEL BACKING: 3'X7'. RAISED
ALUMINUM OR STAINLESS STEEL LETTERS, WELDED TO
BACKING: 5" TALL. CONTRACTOR TO PROVIDE
MANUFACTURER'S FULL RANGE OF FONT STYLES,
MATERIALS AND SIZES FOR GOVERNMENT APPROVAL.
CONTRACTOR TO VERIFY WITH OWNER ON EXACT
WORDING OF SIGNAGE.
10.03 1/4" UNCOATED STEEL PANEL BACKING: 3'-4"X3'-4".
CENTER WITHIN RECESS. RAISED ALUMINUM OR
STAINLESS STEEL LETTERS, WELDED TO BACKING: 3"
TALL. CONTRACTOR TO PROVIDE MANUFACTURER'S
FULL RANGE OF FONT STYLES, MATERIALS AND SIZES
FOR GOVERNMENT APPROVAL. CONTRACTOR TO
VERIFY WITH OWNER ON EXACT WORDING OF SIGNAGE.
26.06 LIGHT FIXTURE. SEE ELECTRICAL.
26.32 SOLAR PANELS.
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
ELEVATION GENERAL NOTES
1. COORDINATE GRADING SHOWN ON ELEVATIONS WITH
CIVIL.
2. FOR WALL TYPES SEE WALL SECTIONS, FLOOR PLANS,
AND ASSEMBLY TYPES FOR LOCATIONS AND
CONSTRUCTION.
3. PROVIDE GUTTERS AND DOWNSPOUTS WITH HEAT
CABLING, INCLUDING REQUIRED ELECTRICAL SERVICE
AND CONTROLS. COORDINATE WITH FEATURES
INDICATED ON ROOF PLAN.
4. SEE ROOF PLAN FOR LOCATIONS AND EXTENTS OF
SNOW CLIPS AND SNOW GUARDS IN COLD CLIMATES.
COORDINATE WITH ROOF PLAN.
MAIN LEVEL
0' - 0"
T.O. HIGH WALL
18' - 5"
ABCDE
2" / 1'-0"
AE301
T.O. LOW WALL
11' - 4"
AE301
7.85
8.16
B B B B
1 1/2" / 1'-0"
5.59
7.85
26.06
7.59
R2
26.32
E
5.49
5.49
5.59
4.10
4.10
4.12
4.11
T.O. ENTRY WALL
14' - 8"
T .O
C
O N
C R
E T
E
23.36
3.063.06
AE512
MAX, TYP.
6' - 8"
MAIN LEVEL
0' - 0"
T.O. HIGH WALL
18' - 5"
A B C D E2
AE301
2" / 1'-0"
1 1/2" / 1'-0"
T.O. LOW WALL
11' - 4"
AE301
7.86
8.16
8.07
7.86
B B B
26.06
7.85
26.06
5.59
7.85
26.32
E E
5.49 5.49
4.10
26.06
4.11
4.10
4.12
T.O. ENTRY WALL
14' - 8"
T .O
C
O N
C R
E T
E
23.35
3.06
3.06
AE512
AE512
1 1
MAX, TYP.
6' - 8"
MAX, TYP.
6' - 8"
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :4
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
B U
IL
D
IN
G
E L E V A T
IO
N S
AE202
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
S C
K U
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
27 78
KEYNOTE LEGEND
3.06 CONTROL JOINT.
4.10 CMU BLOCK.
4.11 HONED CMU ACCENT STRIP.
4.12 SPLIT FACE CMU WAINSCOT.
5.49 CANOPY.
5.59 SHADE STRUCTURE. REFER TO STRUCTURAL.
7.59 STANDING SEAM ROOF. SEE ROOF TYPES.
7.85 METAL DOWNSPOUT.
7.86 SHEET METAL FASCIA PANEL.
8.07 DOOR. SEE DOOR SCHEDULE.
8.16 WINDOW. SEE WINDOW TYPES.
23.35 OUTSIDE AIR INTAKE. REFER TO MECHANICAL DRAWINGS.
23.36 EXHAUST AIR OUTLET. REFER TO MECHANICAL DRAWINGS.
26.06 LIGHT FIXTURE. SEE ELECTRICAL.
26.32 SOLAR PANELS.
0' 2'1'1' 3' 4' 5' 6' 7'AE202
BUILDING ELEVATION - EAST1
0' 2'1'1' 3' 4' 5' 6' 7'AE202
BUILDING ELEVATION - WEST2
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
MAIN LEVEL
0' - 0"
2"2' - 1"
3' - 0"
5.65
8.31
6.31
MAIN LEVEL
0' - 0"
11"
1"
2' - 0"
2"
5.65
8.31
6.31
6.31
MAIN LEVEL
0' - 0"
1' - 0"
1"
2"
5.65
8.31
6.31
DETAIL AND SECTION
GENERAL NOTES
1. SEE ASSEMBLIES SHEET FOR WALL, ROOF AND FLOOR
CONSTRUCTION.
1.23
5.60
5.58
7.95
7.93
7.94
/2
1' - 11"1' - 11"
5.57
7.96
5.56
5.64
C
T.O. ENTRY WALL
14' - 8"
R2
R2
EM86
5.59 7.01
5.03
9.05
AE512
7.95
7.94
7.93
MAIN LEVEL
0' - 0"
1' - 0"
6.53
EM83
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :1
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
S E C T
IO
N
D E T A
IL
S
AE511
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
S C
K U
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
35 78
0'1' 2'1'AE511
RECEPTION DESK - ADA TRANSACTION6
0'1' 2'1'AE511
RECEPTION DESK - SEATING5
0'1' 2'1'AE511
RECEPTION DESK - SIDE WALL4
KEYNOTE LEGEND
1.23 SCHEDULE WALL. REFER TO ASSEMBLY TYPES AND FLOOR
PLAN.
5.03 3 5/8" METAL STUD FRAMING @ 16" O.C.
5.56 INTERMEDIATE HSS823/16 MEMBERS AS NEEDED FOR 6'-8"
SPAN MAX. FILLET WELD ALL-AROUND (GRIND SMOOTH)
U.N.O. IN STRUCT DRAWINGS.
5.57 TUBE STEEL. HSS8X2X3/16 X CONT. U.N.O. IN STRUCT
DRAWINGS.
5.58 STEEL ANGLE. (3) L3X3X1/4 (LLV) BETWEEN EACH HSS. WELD
EACH END TO HSS W/ 3/16" FILLET WELD ALL-AROUND (GRIND
SMOOTH) U.N.O. IN STRUCT DRAWINGS.
5.59 SHADE STRUCTURE. REFER TO STRUCTURAL.
5.60 ROD THREADED ENDS AND SLEEVE NUT.
5.64 PERFORATED AND CORRUGATED SHEET METAL PANELS, SEE
SPECS.
5.65 2"X2" ALUMINUM FRAME.
6.31 COUNTERTOP.
6.53 STAINLESS STEEL WRITING SHELF MOUNTED ON BRACKETS.
SEE SPEC.
7.01 (1)LAYER 5/8" GYPSUM BOARD".
7.93 COUNTER FLASHING.
7.94 ROOF FLASHING.
7.95 MASONRY MOUNT REGLET FRAME.
7.96 ATTACH TO TS WITH NEOPRENE WASHER.
8.31 PERSONAL PROTECTIVE WINDOW WITH 6" PASS THROUGH
ABOVE COUNTER.
9.05 GYP. BD. PAINT.
0'1' 2'1'AE511
TYP. CANOPY1
0'1' 2'1'AE511
VESTIBULE CEILING2
0'1' 2'1'AE511
WRITING SHELF SECTION3
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
1 2 3 4
A
B
C
D
E
MED
UNIT
TOILET
MECHANICAL
BREAKROOM
JANITOR
STORAGE
MED.
STORAGE
WOMEN'S
TOILET
MEN'S
TOILET
RECEPTION
CONFERENCE
CASH
ROOM
LOBBY
HALL
WORK
AREA
117STORAGE
HALL
COMM.
113A
E-1
112A
111A
A
113A
E-1
I-3
I-3
I-4
I-4
I-2
I-1
I-1
I-2
I-4
I-4
I-2
I-2
I-2
I-2
I-2
I-2I-2
I-1
I-1
I-3
VESTIBULE
I-3
SIGNAGE PLAN GENERAL NOTES
1. ALL SIGNAGE SHALL COMPLY WITH AMERICANS WITH
DISABILITIES ACT (ADA).
2. SEE SIGNAGE MOUNTING HEIGHT FOR TYPICAL
INSTALLATION HEIGHT OF SIGN TYPES.
3. FINAL SIGNAGE FINISHES TO BE SELECTED FROM FULL
RANGE OF MANUFACTURER'S STANDARD FINISHES.
4. ALL FINAL TEXT SHALL BE SELECTED BY THE GOVERNMENT
APPROVED REPRESENTATIVE. ALL ROOM NAMES AND
NUMBERS LISTED ON SIGNAGE SCHEDULES ARE FOR
REFERENCE ONLY.
5. VERIFY ROOM NUMBERS AND WORDING WITH
GOVERNMENT APPROVED REPRESENTATIVE. MAXIMUM 4
DIGIT ROOM NUMBERS AND MAXIMUM 25 CHARACTER.
ROOM NAMES TYPICAL ALL SIGNS.
6. SIGN SHALL BE INSTALLED ON WALL ON THE LATCH SIDE OF
THE DOOR UNLESS SHOWN OTHERWISE ON DRAWINGS.
1. PROVIDE MESSAGE INSERTS, VERIFY TEXT WITH
GOVERNMENT APPROVED REPRESENTATIVE.
2. SEE SITE PLAN FOR SIGN LOCATION.
REMARKS:
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :2
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
S
IG
N A G E
P L A N
AG101
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
A u th o r
C h e c k e r
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
40 78
N
0' 2'1'1' 3' 4' 5' 6' 7'AG101
SIGNAGE FLOOR PLAN1
SIGNAGE SCHEDULE
DOOR SIGN TYPE COMMENT
101 I-3
101A I-3
102 I-2
103 I-2
104 I-2
105 I-4
106 I-4
107 I-1
108 I-2
109 E-1, I-3
110 I-2
111 I-2
111A E-1, I-3
112 1-4
112A 1-4
113 I-2
113A I-2
114 I-2
115 I-1
116 I-1
118 I-1
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
ROOM DESCRIPTION
3/32" SEMI-GLOSS
BAKED ENAMEL
A F F
• (ROOM DESCRIPTION): 1/2" UPPER CASE HELVETICA NEUE 55
ROMAN. LETTERING TO BE FLUSH LEFT.
• COLOR TO BE SELECTED FROM MANUFACTURER'S FULL LINE
AND COMPLY WITH COLOR CONTRAST REQUIREMENTS AS
SPECIFIED IN ABAAS.
0' - 9"
ROOM DESCRIPTION
NOTE: (SEE ROOM IDENTIFICATION SIGN OF UFC 3-120-01 FIGURE 4-1)
3/8" THICK MATTE ACRYLIC
TACTILE ROOM
NUMBER W/BRAILLE
PRINTED PAPER INSERT
W/PROTECTIVE COVERING
A F F
• (ROOM NUMBER): 1 1/2" TACTILE HELVETICA NEUE 55 ROMAN
CHARACTERS RAISED 0.03125" FROM SURFACE WITH GRADE
TWO BRAILE, FLUSH LEFT 3/8" BELOW.
• (ROOM DESCRIPTION): PRINTED PAPER INSERT WITH
PROTECTIVE CLEAR ACRYLIC COVER. UPPER AND LOWER
CASE HELVETICA NEUE 55 ROMAN, 3/4" CAPITOL LETTER
HEIGHT, FLUSH LEFT. INSERT AREA - WILL ACCOMMODATE
FOUR LINES WITH A MAXIMUM 21 CHARACTERS PER LINE.
• COLOR TO BE SELECTED FROM MANUFACTURER'S FULL LINE
AND COMPLY WITH COLOR CONTRAST REQUIREMENTS AS
SPECIFIED IN ABAAS.
0' - 8 1/2"
0' - 9"
REMOVABLE END CAPS
(BOTH SIDES)
/2
/2 "0
/2
1/2"
ROOM DESCRIPTION
NOTE: (SEE PERMANENT ROOM IDENTIFICATION SIGN OF UFC 3-120-01
FIGURE 4-2)
3/8" THICK MATTE ACRYLIC
TACTILE ROOM
NUMBER W/BRAILLE
TACTILE ROOM
DESCRIPTION W/BRAILLE
A F F
• (ROOM NUMBER): 1 1/2" TACTILE HELVETICA NEUE 55 ROMAN
CHARACTERS RAISED 0.03125" FROM SURFACE WITH GRADE
TWO BRAILE, FLUSH LEFT 3/8" BELOW.
• (ROOM DESCRIPTION): 3/4" TACTILE HELVETICA NEUE 55
ROMAN CAPITOL LETTERS RAISED 0.03125" FROM SURFACE
WITH GRADE TWO BRAILE. LETTERING TO BE FLUSH LEFT.
AREA WILL ACCOMMODATE FOUR LINES WITH A MAXIMUM 21
CHARACTERS PER LINE.
• COLOR TO BE SELECTED FROM MANUFACTURER'S FULL LINE
AND COMPLY WITH COLOR CONTRAST REQUIREMENTS AS
SPECIFIED IN ABAAS.
0' - 9"
REMOVABLE END CAPS
(BOTH SIDES)
" 0
/2
/2 "0
/2
1/2"
EXIT
NOTE: (SEE TACTILE EXIT SIGN OF UFC 3-120-01 FIGURE 4-10)
3/8" THICK MATTE ACRYLIC
TACTILE EXIT W/BRAILLE
A F F
• (ROOM NUMBER): 1 1/2" TACTILE HELVETICA NEUE 55 ROMAN
CHARACTERS RAISED 0.03125" FROM SURFACE WITH GRADE
TWO BRAILE, FLUSH LEFT 3/8" BELOW.
• (ROOM DESCRIPTION): 3/4" TACTILE HELVETICA NEUE 55
ROMAN CAPITOL LETTERS RAISED 0.03125" FROM SURFACE
WITH GRADE TWO BRAILE. LETTERING TO BE FLUSH LEFT.
AREA WILL ACCOMMODATE FOUR LINES WITH A MAXIMUM 21
CHARACTERS PER LINE.
• COLOR TO BE SELECTED FROM MANUFACTURER'S FULL LINE
AND COMPLY WITH COLOR CONTRAST REQUIREMENTS AS
SPECIFIED IN ABAAS.
0' - 9"
NOTE: (SEE ACCESSIBLE RESTROOM IDENTIFICATION SIGN OF
UFC 3-120-01 FIGURE 4-4)
A F F
• (ROOM NUMBER): 1 1/2" TACTILE HELVETICA NEUE 55 ROMAN
CHARACTERS RAISED 0.03125" FROM SURFACE WITH GRADE
TWO BRAILE, FLUSH LEFT.
• (ROOM DESCRIPTION): 1" TACTILE HELVETICA NEUE 55 ROMAN
CHARACTERS RAISED 0.03125" FROM SURFACE WITH GRADE
TWO BRAILE, FLUSH LEFT, MAXIMUM OF 7 CHARACTERS.
• COLOR TO BE SELECTED FROM MANUFACTURER'S FULL LINE
AND COMPLY WITH COLOR CONTRAST REQUIREMENTS AS
SPECIFIED IN ABAAS.
" 0
/2
/2 "0
/2
MEN
/4
/8 "0
/8
3/8" THICK MATTE
ACRYLIC
OPTIONAL TACTILE
ROOM NUMBER
W/BRAILLE
0' - 9"
6" PICTOGRAM
SYMBOL BASED ON
SIGN LOCATION
TACTILE ROOM
DESCRIPTION
W/BRAILLE
0' - 8 1/2"
P L O T
D A T E
P L O T T E D
B Y
C H K 'D
B Y
D E S
IG
N
O F F
IC
E
D E S
IG
N E D
B Y
P R O J E C T
N O
D R A W N
B Y
A P P R O V E D
B Y
U N
IT
E D
S T A T E S
D E P A R T M E N T
O F
T H E
IN
T E R
IO
R
B U R E A U
O F
L A N D
M A N A G E M E N T
D A T E
D E S C R
IP
T
IO
N
M A R K
A P P R O V E D
D A T E
SHEET OF
:1 :3
P M
C U s e rs k u n d e rw o o d D o c u m e n ts
B L M
L it tl e
S a h a ra re v is e d ro o f_ k a it u n d e rw o o d .r v t
S
IG
N A G E
D E T A
IL
S
AG501
L
IT
T L E
S A H A R A
V
IS
IT
O R
C E N T E R
R E P L A C E M E N T
A u th o r
C h e c k e r
D e s ig n e r
A p p ro v e r
W E S T
D E S E R T
D
IS
T R
IC
T
U T A H
41 78
B
ID
D
IN
G
C L
A R
IF
IC
A T
IO
N
/2
/2
AG501
TYPE "E-1" EXTERIOR ROOM ID.1
AG501
TYPE "I-1" - PERMANENT ROOM ID2
AG501
TYPE "I-2" - PERMANENT ROOM ID3
AG501
TYPE "I-3" - PERMANENT ROOM ID4
AG501
TYPE "I-4" - PERMANENT ROOM ID5 1
| Sheets |
| G002 - INDEX SHEET |
| AE101 - FLOOR PLAN |
| AE110 - DIMENSION PLAN |
| AE121 - ROOF PLAN |
| AE151 - REFLECTED CEILING PLAN |
| AE201 - BUILDING ELEVATIONS |
| AE202 - BUILDING ELEVATIONS |
| AE251 - INTERIOR ELEVATIONS |
| AE252 - INTERIOR ELEVATIONS |
| AE301 - BUILDING SECTIONS |
| AE302 - BUILDING SECTIONS |
| AE351 - WALL SECTIONS |
| AE401 - ENLARGED PLANS |
| AE501 - PLAN DETAILS |
| AE511 - SECTION DETAILS |
| AE512 - SECTION DETAILS |
| AE601 - DOOR/WINDOW TYPES AND SCHEDULES |
| AE610 - DOOR AND WINDOW DETAILS |
| AF101 - FINISH FLOOR PLAN |
| AG101 - SIGNAGE PLAN |
| AG501 - SIGNAGE DETAILS |
| GI-002 - ABBREVIATIONS |
| GI-003 - GENERAL INFORMATION |
| GI-101 - LIFE SAFETY PLAN |
| GI-501 - WALL, ROOF, CEILING & FLOOR ASSEMBLY TYPES |
| GI-701 - ACCESSIBILITY COMPLIANCE |
| GI-702 - ACCESSIBILITY COMPLIANCE |
File details come from the government source that posted it. Updated .