This is an architectural drawing sheet containing wall section details for a proposed residence quarters project at Pelican Island National Wildlife Refuge. The document, prepared by Hydra Engineering & Construction LLC for the U.S. Fish & Wildlife Service, presents three detailed wall sections (labeled 1, 2, and 3) depicting construction specifications and material assemblies for the building envelope.

The wall sections illustrate a structural system utilizing 6.5-inch Structural Insulated Panel (SIPS) wall construction with 5/8-inch gypsum board interior finish, exterior cladding of 1/2-inch Hardie Plank siding with paint finish, and a foundation consisting of a 4-inch concrete slab on grade with a 2x10 pressure-treated skirt board. The roof assembly comprises 8.25-inch SIPS roof panels topped with architectural shingles on ice and water shield dam membrane, with prefinished metal drip edge and Hardie Plank fascia board details. Additional specifications include hurricane-resistant double-hung windows with 1-inch thick insulated low-E glass, air barrier continuity throughout the envelope, 10-mil vapor barrier on stucco finishes, and detailed curb and lattice skirting design with 1x6 lattice boards spaced 1/4-inch apart. The building dimensions show a finished floor elevation at 2'-6" and a top-of-roof elevation at 20'-1". Two revisions to the drawing are noted: Revision #1 reflecting Value Engineering changes dated January 29, 2016, and Revision #2 incorporating 95% U.S. Fish & Wildlife Service comments dated April 29, 2016.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

GROUND

0'-0"

FINISH FLOOR

2'-6"

T.O. PLATE

12'-8"

T.O. ROOF

20'-1"

ARCHITECTURAL SHINGLE

ROOF ON ICE & WATER

SHIELD DAM MEMBRANE ON

8 1/4" SIPS ROOF PANEL

1/2" HARDIE PLANK

SIDING; PAINTED

6 1/2" SIPS WALL PANEL

1/2" HARDIE PLANK

SOFFIT PANEL; PAINTED

COORD. LAYOUT OF

SEAMS W/ BATTON STRIPS

4" CONCRETE

SLAB ON GRADE

6 1/2" SIPS WALL

PANEL W/ 5/8"

GYP. BD.

HURRICANE RESISTANT

DOUBLE HUNG WINDOW

WITH 1" THK. INSULATED

LOW-E GLASS

ARCHITECTURAL SHINGLE

ROOF ON ICE & WATER DAM

MEMBRANE ON 8 1/4" SIPS

ROOF PANEL

PREFINISHED METAL DRIP

EDGE

HARDIE PLANK FASCIA

BOARD; PAINTED

1X10 FASCIA

BOARD

6 1/2" SIPS WALL

PANEL W/ 5/8"

GYP. BD.

BUILT-UP WOOD

BEAM

B

AIR BARRIER

AIR BARRIER

AIR BARRIER

STUCCO FINISH

10 MIL VAPOR BARRIER

BRACKET TRIM PIECE

5/4X4 DIAGONAL AND 4X4

VERT. & HORIZ. MEMBERS

A303

2x10 P.T. SKIRT BOARD

DRIP EDGE W/ FLASHING

P.T. 2X NAILER

GROUND

0'-0"

FINISH FLOOR

2'-6"

A

1x4 CURB

2X4 BLOCKING CURB SUPPORT

@24" O.C.

2 1/2"

2x4 COLUMN SUPPORT

FOR LATTICE BOARD

1X6 LATTICE BOARD

SPACED 1/4" APART

1/

2x10 P.T. SKIRT BOARD

T.O. ROOF

20'-1"

B

1' - 6 1/2" 1"1" 1/2"

1'

1/

1/

1'

5"

1 1/4

1"

1x10 FASCIA BOARD

ALUM. DRIP EDGE

ARCHITECTURAL SHINGLE ROOF

SIPS ROOF PANEL

FIBER CEMENT SOFFIT BOARD

5/4x8 CORNICE BOARD

4X4 P.T. WOOD POST WITH CHAMFERED EDGE

5/4x4 P.T. WOOD BRACKET PIECE

4X4 P.T. WOOD POST WITH CHAMFERED EDGE

GENERAL NOTES

Project Sheet

Date

Scale

US FISH & WILDLIFE SERVICE

PELICAN ISLAND NWR,

PROPOSED RESIDENCE QUARTERS

& ROADWAY EXTENSION

Project Name and Address

Firm Name and Address

HYDRA ENGINNEERING &CONSTRUCTION LLC.

36 JASPER THOMAS ROAD

CRAWFORDVILLE, FL 32327

(850) 926-2593 PHONE

(850) 926-9257 FAX

No. Revision/ Issue Date

Lyman Davidson Dooley, Inc.

FOR CONSTRUCTION

As indicated

A30305/09/2016

4R-FLA-400-XXX

WALL SECTIONS

3/4" = 1'-0"1 WALL SECTION

1 1/2" = 1'-0"2 CURB AND LATTICE DETAIL

1 1/2" = 1'-0"3 BRACKET DETAIL

1 REVISION #1 VE CHANGES 1/29/16

2 95% USFWS COMMENTS 4/29/16

File details come from the government source that posted it. Updated .