This is an architectural drawing sheet containing wall section details for a proposed residence quarters project at Pelican Island National Wildlife Refuge. The document, prepared by Hydra Engineering & Construction LLC for the U.S. Fish & Wildlife Service, presents three detailed wall sections (labeled 1, 2, and 3) depicting construction specifications and material assemblies for the building envelope.
The wall sections illustrate a structural system utilizing 6.5-inch Structural Insulated Panel (SIPS) wall construction with 5/8-inch gypsum board interior finish, exterior cladding of 1/2-inch Hardie Plank siding with paint finish, and a foundation consisting of a 4-inch concrete slab on grade with a 2x10 pressure-treated skirt board. The roof assembly comprises 8.25-inch SIPS roof panels topped with architectural shingles on ice and water shield dam membrane, with prefinished metal drip edge and Hardie Plank fascia board details. Additional specifications include hurricane-resistant double-hung windows with 1-inch thick insulated low-E glass, air barrier continuity throughout the envelope, 10-mil vapor barrier on stucco finishes, and detailed curb and lattice skirting design with 1x6 lattice boards spaced 1/4-inch apart. The building dimensions show a finished floor elevation at 2'-6" and a top-of-roof elevation at 20'-1". Two revisions to the drawing are noted: Revision #1 reflecting Value Engineering changes dated January 29, 2016, and Revision #2 incorporating 95% U.S. Fish & Wildlife Service comments dated April 29, 2016.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GROUND
0'-0"
FINISH FLOOR
2'-6"
T.O. PLATE
12'-8"
T.O. ROOF
20'-1"
ARCHITECTURAL SHINGLE
ROOF ON ICE & WATER
SHIELD DAM MEMBRANE ON
8 1/4" SIPS ROOF PANEL
1/2" HARDIE PLANK
SIDING; PAINTED
6 1/2" SIPS WALL PANEL
1/2" HARDIE PLANK
SOFFIT PANEL; PAINTED
COORD. LAYOUT OF
SEAMS W/ BATTON STRIPS
4" CONCRETE
SLAB ON GRADE
6 1/2" SIPS WALL
PANEL W/ 5/8"
GYP. BD.
HURRICANE RESISTANT
DOUBLE HUNG WINDOW
WITH 1" THK. INSULATED
LOW-E GLASS
ARCHITECTURAL SHINGLE
ROOF ON ICE & WATER DAM
MEMBRANE ON 8 1/4" SIPS
ROOF PANEL
PREFINISHED METAL DRIP
EDGE
HARDIE PLANK FASCIA
BOARD; PAINTED
1X10 FASCIA
BOARD
6 1/2" SIPS WALL
PANEL W/ 5/8"
GYP. BD.
BUILT-UP WOOD
BEAM
B
AIR BARRIER
AIR BARRIER
AIR BARRIER
STUCCO FINISH
10 MIL VAPOR BARRIER
BRACKET TRIM PIECE
5/4X4 DIAGONAL AND 4X4
VERT. & HORIZ. MEMBERS
A303
2x10 P.T. SKIRT BOARD
DRIP EDGE W/ FLASHING
P.T. 2X NAILER
GROUND
0'-0"
FINISH FLOOR
2'-6"
A
1x4 CURB
2X4 BLOCKING CURB SUPPORT
@24" O.C.
2 1/2"
2x4 COLUMN SUPPORT
FOR LATTICE BOARD
1X6 LATTICE BOARD
SPACED 1/4" APART
1/
2x10 P.T. SKIRT BOARD
T.O. ROOF
20'-1"
B
1' - 6 1/2" 1"1" 1/2"
1'
1/
1/
1'
5"
1 1/4
1"
1x10 FASCIA BOARD
ALUM. DRIP EDGE
ARCHITECTURAL SHINGLE ROOF
SIPS ROOF PANEL
FIBER CEMENT SOFFIT BOARD
5/4x8 CORNICE BOARD
4X4 P.T. WOOD POST WITH CHAMFERED EDGE
5/4x4 P.T. WOOD BRACKET PIECE
4X4 P.T. WOOD POST WITH CHAMFERED EDGE
GENERAL NOTES
Project Sheet
Date
Scale
US FISH & WILDLIFE SERVICE
PELICAN ISLAND NWR,
PROPOSED RESIDENCE QUARTERS
& ROADWAY EXTENSION
Project Name and Address
Firm Name and Address
HYDRA ENGINNEERING &CONSTRUCTION LLC.
36 JASPER THOMAS ROAD
CRAWFORDVILLE, FL 32327
(850) 926-2593 PHONE
(850) 926-9257 FAX
No. Revision/ Issue Date
Lyman Davidson Dooley, Inc.
FOR CONSTRUCTION
As indicated
A30305/09/2016
4R-FLA-400-XXX
WALL SECTIONS
3/4" = 1'-0"1 WALL SECTION
1 1/2" = 1'-0"2 CURB AND LATTICE DETAIL
1 1/2" = 1'-0"3 BRACKET DETAIL
1 REVISION #1 VE CHANGES 1/29/16
2 95% USFWS COMMENTS 4/29/16