This document is a generic installation plan for rooftop photovoltaic (PV) solar array systems designed for residential and commercial applications in Florida. The plan consists of eight pages detailing structural specifications, wind load calculations, system certifications, electrical diagrams, and racking layouts.

The plan specifies installation requirements for SolarWorld Sunmodule Plus SW 290-300 MONO solar panels mounted using the Sunfix Plus pitched roof mounting system with Enphase micro-inverters. Key technical requirements include: solar equipment adds less than 4 psf gravity load; two mounting rails required under each module with OEM module clamps at all crossing points; roof attachment via framing methods (QuickmountPV E-Mount or Universal Tile Mount) or S-5 standing seam clamps; maximum roof attachment spacing of 4 feet in pressure zones PZ1 and PZ2, and 2 feet in PZ3 (with no PZ3 usage in Miami-Dade County). The Sunfix Plus system supports 170 mph wind loads and 50 psf snow loads per ASCE 7-05 standards, with roof pitch capability from 0° to 45°. Installation must comply with 2014 Florida Building Code (5th Edition) and 2012 NFPA 1 standards. The plan includes structural details for roof penetration, flashing, and Enphase inverter mounting (rated up to 113 psf, torqued to 16 ft-lbs minimum). SolarWorld modules feature 25-year linear performance warranty and 20-year product warranty, with extreme weather resistance and PID-free certification per IEC 62804-1. The engineer of record is Allen Gezelman, with contact at allen@gezelmanpe.com.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A

B

C 0 w a..

<t:

...J w N

C, D I

E z

:i a:

J:

OIS

z w F C, a:

:3 zw i

�a:

it w :E w

CJ)

a.

a. a: ::::, w (/)

(/) a:::::, w J: Ill:::,: I-

0 u.i 0 � ;,f !z wO<t; w 0 o z;'2;z zo::::> 0 1- Ill - < � a.a o

� "ai a: e, C:

0 :ii: (/) Ql

���f --::::>o �>z� � fil � 8-z !;!; � ai-zwE �C,QQi (/)<t;QN w �I-� �fil� � �9 w := a.> O::::; oo ..

za:< a.

:5 0. �fa.�:J� !:Q -a: 0 :r:ZWw i-oa. (/) u.ci)>-(J)oa::r:w zW(/) 0 o>WO-oO< (J)->wa:zom

����1-I-0 zO -WU) :::,: 0:-1-1 • a.w<w

8 7

GENERAL NOTES:

This is a multiple page generic plan consisting of 8 pages.

Page 1 - Structural details for the attachment of the OEM racking and mounting system, roof penetration and flashing details and Enphase inverter mounting detail. Page 2 - Wind load calculations. Page 3 - Florida Solar Energy Center (FSEC) PV system certification. Page 4 -Solar World module and Enphase inverter specifications.

Page 5 - Electrical diagram (3 - 16) module systems.

Page 6 - Electrical diagram (17 - 32) module systems.

Page 7 - Electrical diagram (33 - 40) module systems.

Page 8 - Example of racking layout.

This plan is intended to provide the essential information needed by AHJ (Authority Having Jurisdiction) and installers.

An electronic version (EV) of this plan is available to users to provide easy access to supplemental information. If a conflict should occur between a drawing and / or specification hereon and an OEM (Original Equipment Manufacturer) detail, OEM shall prevail.

1. Solar equipment adds less than 4-psf gravity load to the structure.

2. There shall be two mounting rails under each module.

3. Modules shall attach to the rails using OEM module clamps at all rail to module crossing points.

4. There are two roof attachment methods acceptable under this plan. Method depends on roofing type - see details in drawing figures heron:

a. Framing - shingle and tile

b. S-5 or equivalent standing seam clamp

5. Rails shall attach to L-feet and/or stand-offs, thence to roof by CRS (corrosion resistant steel) lags, hanger bolts, or OEM fasteners through flashings:

i. Framing - Shingle and Tile

1. QuickmountPV E-Mount

2. QuickmountPV Universal Tile Mount

6. PV modules may be instf!lled in PZ1, PZ2, or PZ3.

Maximum center-to-center roof attachment spacing shall be 4-ft in PZ1, 4-ft in PZ2, and 2,-ft in PZ3. There shall be no PZ3 usage within Miami- Dade.

7. Contractor shall provide additional information to AHJ (Authority Having Jurisdiction) as may be required. Such as by Miami-Dade solar guidelines.

https://www.miamidade.gov/building/library/guidelines/ solar-systems-permit.pdf

EOR (engineer of record) prefers email communications:

allen@gezelmanpe.com

6 5 4 3 2

APPLICABLE CODE: WIND LOAD: / SCOPE OF WORK:

2014 FBC (5TH EDITION SEE WIND CALC.

FLORIDA BUILDING CODE) ON PAGE 2

CONTRACTOR SHALL COMPLY WITH SOLAR PROVISIONS 2012 NFPA 1

http:/ /gezelmanpe.corn/Generic/NFPA 1 . pdf INSTALLATION OF A PV SYSTEM

'-WITH A ROOFTOP PV ARRAY

SOLAR UNIT (THERMAL OR PV) WIND FORCES

SOLAR UNITS INSTALLED PER THIS PLAN SHALL N.QI FORM PART OF THE BUILDING ENVELOPE LIKE A WINDOW, DOOR, SKYLIGHT, OR BIPV. SOLAR UNITS SHALL BE MOUNTED ABOVE ROOF SURFACE LIKE AN AC CONDENSER, THEREFORE, SOLAR UNITS THUS INSTALLED DO NOT REQUIRE A PRESSURE RATING AS DO ENVELOPE COMPONENTS SUCH AS WINDOWS, DOORS & SKYLIGHTS. SOLAR UNITS SHALL BE MOUNTED VERY CLOSE TO THE ROOF SURFACE, THIS PROVIDES PRESSURE EQUALIZATION BETWEEN THE ROOF SURFACE AND THE BACK OF THE SOLAR UNITS . THIS RESULTS IN NO SIGNIFICANT CHANGE IN THE LOADS ON THE ROOF FRAMING FOR A PARALLEL MOUNT AND MODEST CHANGES IF TILT UP.

HOWEVER, THE INTERNAL AND EXTERNAL COMPONENTS OF WIND PRESSURE DECOUPLE, E.G. THE ROOF RESISTS THE INTERNAL WIND PRESSURES AND THE SOLAR UNITS RESIST THE EXTERNAL WIND PRESSURES. THE EXTERNAL WIND FORCES ARE THEN TRANSFERRED TO THE ROOF FRAMES THROUGH THE SOLAR ATTACHMENT HARDWARE.

WIND CALCULATIONS LINK HERE. HTTP://WWW.GEZElMANPE.COM/GENERIC/2010FBC_WINDCALCS.HTM

VOID IF MY SIGNATURE &

RAISED OR ELECTRONIC

SEAL IS NOT APPLIED

SOLARWORLD MODULE - ---·--·--20·-•i·---------·-

PENETRATION DETAIL

SCALE:NTS

ROOF PROTRUSION

ROOF

VALLEY

ATIIC VENT

-1,'f'G"

SUNFIX PLUS SPLICE DETAIL

SCALE:NTS

REVIEVVf[j, f_;v, DEC O 6 2016

ROOF VALLEY

SUNFIX PLUS L-BRACKET

& QUICK MOUNT COMP

ROOF PENETRATION

ARRAY DETAILS

SCALE: 3/8" =1'

• THIS LAYOUT USES (2) ADDITIONAL SPLICES

OPTIONAL LAYOUT

SCALE:NTS

Sunfix'plus· The intelligent pitched fQOfmounting system

5-Tile Standing seam clamp SUNAX PLUS 2 RAIL

(SEENOTE9)

Composition shingle Flat tile

ROOF MOUNTING DETAIL

SCALE: NTS

f Li >=0 T(See Note #1 O)

EC0606 FLANGE NUT, 6/16-18

ENPHASE MICRO INVERTER

MECHANICAL NOTES:'

9. 00 NOT ATTACH ANY HARDWARE ON TOP OF RAIL DIRECTLY UNDER SOLAR MODULE. DOING SO MAY VOID MODULE WARRANTY.

10. INSTALL ENPHASE INVERTER WITH 5116" AND MS HARDWARE AB SHOWN. TORQUE ENPHASE MOUNTING HARDWARE TO 16 FT·LBS MINIMUM.

ENPHASE MOUNTING DETAIL RATED UPTO 113PSF.

ENPHASE MOUNTING DETAIL

SCALE: 6" = 1 '-0"

OEM RACKING AND MOUNTING - SUNFIX

SCALE: NTS

ENGINEER

ALLEN GEZELMAN

16 502 HANNA RD.

LUTZ, FLORIDA

33549

PH 813 9091966

allen@gezelmanpe.com www.gezelmanpe.com z C\I

:5 '<:t

a. a:

> C/J :r: a.

01:S a: I- -U) W � cc w I-w ..J � 0 z :) cc WOzLL <!:IO-cn c:Eow

"0�1-a.a.

3: wz0a. en- -<Ccc<@a:

(.) :5 :r: a: ww a. - z

U>OZ��

LL U) W 0.:

ORAWN O ANSI B 17• X 11 '1

PRINT SIZ6 w.y VARY.

, .... PROVIDER

1423 Gunn Highway Odessa, FL 33556

'-. 813-403-5100 .J

/ DATE: 08/27/2015 11 :30 AM '"'I

61 LDR-MI-SW290M

Rev. 08.16

A

C

D

E

F

THE INTELLIGENT PITCHED ROOF

MOUNTING SYSTEM

The SolarWorld Sunfix plus pitched roof mounting system is optimized for simple and efficient installation of SolarWorld Sunmodule solar panels. The Sunfix plus system offers many value-added improvements enabling trouble free assembly.

For flush mounting to pitched roofs

Easily adaptable to most roof types: composition shingle, standing metal seam, flat or curved concrete tile, and shake

Supports high wind and snow loads

Pre-assembled components designed for fast and easy installation

Preset rail lengths simplify planning and reduce material cut-off

P.E. certified to IBC 2012, CBC 2013, ASCE 7-05, ASCE 7-10, and Seismic

Online configurator creates custom BOM & pricing instantly

Black racking also available to match SolarWorld’s black framed solar panels

UL Certified Class A Fire system when used with new Sunskirt accessory

Aesthetic and functional Sunskirt available in portrait or landscape orientation with silver or black annodization

Datasheet solarworld.com

Maximum load rating 170 mph wind and 50 psf snow (ASCE 7-05)

Roof pitch 0o to 45o and walls

Rail lengths 2, 3, and 4 modules

Pre-assembled top clamps Stainless steel

Top clamp installation Channel nut design with unique plastic clamp positioning feature

Top clamp colors Silver or black

Splice bar Aluminum, fastener-free installation

Extruded material 6005-T5 aluminum alloy

Aluminum finish Clear (silver) or black anodized

TECHNICAL SPECIFICATIONS

Pre-assembled top-clamp hardware

Unique clamp positioning feature keeps top clamp in place during installation

No field drilling or cutting of rails required

Loose-fitting splice bar with raised index feature allows for thermal expansion while only requiring one roof attachment nearby

Wire management available

Anodized aluminum and stainless steel components resist oxidation affects

Compatible with approved WEEB grounding devices

10-year limited warranty

Black finish available to match SolarWorld's black framed solar panels

UL Certified Class A Fire system when used with Sunskirt accessory

Fully grounded Sunskirt accessory available in four styles: portrait or landscape orientation with silver or black annodization

FEATURES

COMPONENTS

T-Bolt and Nut Assembly Rail Splice Bonding Jumper Assembly Rail Grounding Lug Assembly Roof Attachment (Quick Mount PV shown)

Sunfix plus Rail
Top-Clamp Assembly
End Spacer
Rail Splice Bar

L-Bracket

SW

-0 1-

U S

-2

Optional Sunskirt accessory

QUALITY BY SOLARWORLD

SolarWorld’s foundation is built on more than 40 years of ongoing innovation, continuous optimization and technology expertise. All production steps from silicon to module are established at our production sites ensuring the highest possible quality for our customers. Our modules come in a variety of different sizes and power, making them suitable for all global applications – from residential solar systems to large-scale power plants.

�Extremely tough and stable, despite its light weight – able to handle loads up to 178 psf (8.5 kN/m²)

�Tested in extreme weather conditions – hail-impact tested and resistant to salt spray, frost, ammonia, dust and sand

�Proven guarantee against hotspots and PID-free to

IEC 62804-1

�SolarWorld Efficells™ for the highest possible energy yields

�Patented corner design with integrated drainage for optimized self-cleaning

�High-transmissive glass with anti-reflective coating

�Long-term safety and guaranteed top performance – 25-year linear performance warranty; 20-year product warranty www.solarworld.com

Data sheet

SW 290 - 300 MONO

MADE IN USA

OF US & IMPORTED PARTS

#010 Photovoltaic Collectors_Rcv'd_5-23-17 2.pdf
#010 Photovoltaic Collectors_Rcv'd_5-23-17 10.pdf
#010 Photovoltaic Collectors_Rcv'd_5-23-17 11.pdf
#010 Photovoltaic Collectors_Rcv'd_5-23-17 12.pdf

File details come from the government source that posted it. Updated .