Drawing_A105_-_0122016_30_0001.pdf

PDF 530 KB Posted

Attached to
FL-PELICAN ISLAND NWR-BUNKHOUSE ROOF
Solicitation number
140FC126R0010
Issued by

About this file

This is an architectural construction drawing for a roof plan associated with a federal project for the US Fish & Wildlife Service. The document is a detailed sheet (A105) dated 05/09/2016 for the Pelican Island National Wildlife Refuge Proposed Residence Quarters and Roadway Extension, prepared by Hydra Engineering & Construction LLC located in Crawfordville, Florida, with design by Lyman Davidson Dooley, Inc.

The roof plan specifies architectural shingle roofing with multiple valleys, ridges, and pitch changes ranging from 2.5/12 to 12/12 slopes. Key features include solar panel integration coordinated with electrical systems, valley flashing, ice and water membrane underlayment across the entire roof, and 8.25-inch SIPs panel roof construction. The drawing includes detailed penetration specifications for plumbing vents, exhaust vents, and range hood exhausts, with rubberized boot flashing for pipe penetrations up to 4 inches in diameter. All trim pieces and flashing must be supplied by the roofing manufacturer and installed per manufacturer requirements, with coordination required for clip spacing. The document includes revision notes indicating value engineering changes from January 29, 2016 and USFWS comments incorporated as of April 29, 2016, reflecting a 95% design submission status.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A301

A301

11 3/4" / 12"

11 3/4" / 12"

V A L L E Y

V A L L E Y

PITCH CHANGE

PITCH CHANGE

V A

LLEY

V A

LL

EY

RIDGE

R

ID

G E

RIDGE

PITCH CHANGE

PITCH CHANGE

A303

SOLAR PANELS

COORD. W/

ELECTRICAL

1 2 3 4 5 7

A

B

C

D

E

F

EXHAUST VENT

PLUMBING VENT

EXHAUST VENT

PLUMBING VENT

EXHAUST VENT

PLUMBING VENT

RANGE HOOD EXHAUST

ARCHITECTURAL

SHINGLE ROOF

ARCHITECTURAL

SHINGLE ROOF

RAIN D

IVER

TE

R

RAIN D

IVER

TE

R

R

ID

G E

12" / 12"

12" / 12"

SLOPE SLOPE

SLOPESLOPE

SLOPE

SLOPE

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

S L O

P E

VALLEY FLASHING

VALLEY FLASHING

VALLEY FLASHING

VALLEY FLASHINGVALLEY FLASHING

CONTINUOUS CAULK OR

STAINLESS

STEEL HOSE CLAMP

SET RUBBERIZED BOOT INTO CONT. BEAD

OF CAULK. USE FASTENERS AS SPEC'D

BY BOOT MANUF. - CAULK FASTENER

HEADSARCHITECTURAL

SHINGLE ROOFING

RUBBERIZED BOOT FLASHING

CUT OPENING IN PANEL 1"

SMALLER THAN

PIPE DIA., BACK CUT TABS

AROUND HOLE

& FOLD TABS UP AROUND

PIPE. APPLY

CONT. SEALANT @ JOINT.

8 1/4" SIPS

PANEL ROOF

ROOF PIPE PENETRATION

4" DIA. MAX.

PENETRATION FLASHING

UNDER SHINGLES

GENERAL NOTES

Project Sheet

Date

Scale

US FISH & WILDLIFE SERVICE

PELICAN ISLAND NWR,

PROPOSED RESIDENCE QUARTERS

& ROADWAY EXTENSION

Project Name and Address

Firm Name and Address

HYDRA ENGINNEERING &CONSTRUCTION LLC.

36 JASPER THOMAS ROAD

CRAWFORDVILLE, FL 32327

(850) 926-2593 PHONE

(850) 926-9257 FAX

No. Revision/ Issue Date

Lyman Davidson Dooley, Inc.

FOR CONSTRUCTION

As indicated

A10505/09/2016

4R-FLA-400-XXX

ROOF PLAN

1/4" = 1'-0"1 ROOF PLAN

2 4 810

1/4" = 1' Graphic Scale

N

1. ENTIRE ROOF TO BE UNDERCLAD WITH ICE AND WATER MEMBRANE

2. FLASHING AND CAPS TO BE INSTALLED PER ROOF MANUF. REQUIREMENTS

3. ALL TRIM PIECES TO BE SUPPLIED BY ROOFING MANUFACTURER

4. ALL TRIM TO BE SAME FINISH AS ROOFING MATERIAL

5. COORDINATE WITH ROOF MANUFACTURER FOR CLIP SPACING REQUIREMENTS

ROOF NOTES:

1 1/2" = 1'-0"2 ROOF PENETRATION DETAIL

NOT TO SCALE3 SOLARTUBE DETAIL 1

NOT TO SCALE4 SOLARTUBE DETAIL 2

NOT TO SCALE5 SOLARTUBE DETAIL 3

1 REVISION #1 VE CHANGES 1/29/16

2 95% USFWS COMMENTS 4/29/16

File details come from the government source that posted it. Updated .