This is an architectural construction drawing for a roof plan associated with a federal project for the US Fish & Wildlife Service. The document is a detailed sheet (A105) dated 05/09/2016 for the Pelican Island National Wildlife Refuge Proposed Residence Quarters and Roadway Extension, prepared by Hydra Engineering & Construction LLC located in Crawfordville, Florida, with design by Lyman Davidson Dooley, Inc.
The roof plan specifies architectural shingle roofing with multiple valleys, ridges, and pitch changes ranging from 2.5/12 to 12/12 slopes. Key features include solar panel integration coordinated with electrical systems, valley flashing, ice and water membrane underlayment across the entire roof, and 8.25-inch SIPs panel roof construction. The drawing includes detailed penetration specifications for plumbing vents, exhaust vents, and range hood exhausts, with rubberized boot flashing for pipe penetrations up to 4 inches in diameter. All trim pieces and flashing must be supplied by the roofing manufacturer and installed per manufacturer requirements, with coordination required for clip spacing. The document includes revision notes indicating value engineering changes from January 29, 2016 and USFWS comments incorporated as of April 29, 2016, reflecting a 95% design submission status.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A301
A301
11 3/4" / 12"
11 3/4" / 12"
V A L L E Y
V A L L E Y
PITCH CHANGE
PITCH CHANGE
V A
LLEY
V A
LL
EY
RIDGE
R
ID
G E
RIDGE
PITCH CHANGE
PITCH CHANGE
A303
SOLAR PANELS
COORD. W/
ELECTRICAL
1 2 3 4 5 7
A
B
C
D
E
F
EXHAUST VENT
PLUMBING VENT
EXHAUST VENT
PLUMBING VENT
EXHAUST VENT
PLUMBING VENT
RANGE HOOD EXHAUST
ARCHITECTURAL
SHINGLE ROOF
ARCHITECTURAL
SHINGLE ROOF
RAIN D
IVER
TE
R
RAIN D
IVER
TE
R
R
ID
G E
12" / 12"
12" / 12"
SLOPE SLOPE
SLOPESLOPE
SLOPE
SLOPE
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
S L O
P E
VALLEY FLASHING
VALLEY FLASHING
VALLEY FLASHING
VALLEY FLASHINGVALLEY FLASHING
CONTINUOUS CAULK OR
STAINLESS
STEEL HOSE CLAMP
SET RUBBERIZED BOOT INTO CONT. BEAD
OF CAULK. USE FASTENERS AS SPEC'D
BY BOOT MANUF. - CAULK FASTENER
HEADSARCHITECTURAL
SHINGLE ROOFING
RUBBERIZED BOOT FLASHING
CUT OPENING IN PANEL 1"
SMALLER THAN
PIPE DIA., BACK CUT TABS
AROUND HOLE
& FOLD TABS UP AROUND
PIPE. APPLY
CONT. SEALANT @ JOINT.
8 1/4" SIPS
PANEL ROOF
ROOF PIPE PENETRATION
4" DIA. MAX.
PENETRATION FLASHING
UNDER SHINGLES
GENERAL NOTES
Project Sheet
Date
Scale
US FISH & WILDLIFE SERVICE
PELICAN ISLAND NWR,
PROPOSED RESIDENCE QUARTERS
& ROADWAY EXTENSION
Project Name and Address
Firm Name and Address
HYDRA ENGINNEERING &CONSTRUCTION LLC.
36 JASPER THOMAS ROAD
CRAWFORDVILLE, FL 32327
(850) 926-2593 PHONE
(850) 926-9257 FAX
No. Revision/ Issue Date
Lyman Davidson Dooley, Inc.
FOR CONSTRUCTION
As indicated
A10505/09/2016
4R-FLA-400-XXX
ROOF PLAN
1/4" = 1'-0"1 ROOF PLAN
2 4 810
1/4" = 1' Graphic Scale
N
1. ENTIRE ROOF TO BE UNDERCLAD WITH ICE AND WATER MEMBRANE
2. FLASHING AND CAPS TO BE INSTALLED PER ROOF MANUF. REQUIREMENTS
3. ALL TRIM PIECES TO BE SUPPLIED BY ROOFING MANUFACTURER
4. ALL TRIM TO BE SAME FINISH AS ROOFING MATERIAL
5. COORDINATE WITH ROOF MANUFACTURER FOR CLIP SPACING REQUIREMENTS
ROOF NOTES:
1 1/2" = 1'-0"2 ROOF PENETRATION DETAIL
NOT TO SCALE3 SOLARTUBE DETAIL 1
NOT TO SCALE4 SOLARTUBE DETAIL 2
NOT TO SCALE5 SOLARTUBE DETAIL 3
1 REVISION #1 VE CHANGES 1/29/16
2 95% USFWS COMMENTS 4/29/16