About this file

This file is an architectural drawing and dimensioned floor plan for a federal construction project. The project involves the design of proposed residence quarters and a roadway extension at Pelican Island National Wildlife Refuge for the U.S. Fish & Wildlife Service. The drawing is prepared by Hydra Engineering & Construction LLC (36 Jasper Thomas Road, Crawfordville, FL 32327) and was designed by the architecture firm Lyman Davidson Dooley, Inc.

The floor plan (Sheet A101, dated 05/09/2016, revised 1/29/2016 and 4/29/2016) is drawn at 1/4" = 1'-0" scale and 1 1/4" = 1'-0" scale and includes detailed dimensions for all room layouts, wall openings, and structural elements. The wall schedule specifies six construction types (marks 1-6) with varying compositions including exterior clapboard, stucco finishes, gypsum board, rigid foam insulation, OSB sheathing, wood framing, and masonry. General notes clarify that all exterior wall openings are dimensioned from the exterior face of structural insulated panels (SIPs) to the centerline of openings, while interior partition openings are located from the centerline to the finish face of walls. The project document includes two revisions addressing value engineering changes and U.S. Fish & Wildlife Service comments during the design phase. This is a FOR CONSTRUCTION document intended for the building contractor.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

DN

1/

1/

1/

14' - 0 1/2"

4' - 1 3/4" 3' - 9 3/4"

7' - 11 1/2" 9' - 1 3/4"

5' - 2 1/4" 3' - 11 1/2" 5' - 2 1/2" 5' - 0"

10' - 2"

4' - 3" 3' - 4"

1'

3' - 11 3/4"3' - 11 3/4"

7' - 11 1/2"14' - 0 1/2"

7' - 0 1/4"

2 3

2 2

8' - 4 1/4" 4' - 6"

1' - 10"

1' - 10"

8' - 4 1/4" 4' - 6"

1/

8' - 4 1/4"

8' - 9"

4' - 3 1/2"

9' - 7 1/4"

1/

11' - 2 1/2" 2' - 6 9/16" 11' - 1 3/4" 2' - 6 9/16"

5' - 6 3/16" 2' - 5 5/16"

1/

10' - 11"4

8' - 6 1/4"

1"

1/

1/

2' - 2" 4' - 1" 2' - 2"

7' - 0 1/4"7' - 0 1/4" 7' - 11 3/4"

1 2 3 4 5 7

A

B

C

D

E

F

8' - 1 3/4" 11' - 7"

1/

1/

CJ EJ

EJ

EJEJ CJCJ

CJ

EJ

EJ

CJ

EJ

EJ

CJ

CJ

CJ

EJEJEJEJEJEJ CJCJCJCJCJ

CJ

1'

1/

1/

1' - 10"

1'

1'

5' - 1"

4' - 2 1/8"

10' - 4 7/8"

1/

4' - 2"

2' - 7" 2' - 9" 3' - 0 1/4"

2' - 7" 2' - 9" 3' - 0 1/4"

1/

7' - 4 1/4" 6' - 6 1/4"7' - 0 1/4"

3' - 7 7/8" 5' - 7 3/4"

1/

2' - 7"

6' - 4" 2' - 1 1/2"

1/

3' - 5 3/4"5' - 0"4' - 3 3/4"

7' - 11 1/2"

1/

1/

1/

5' - 7"

1'

4' - 2 3/8"

1/

GENERAL NOTES

Project Sheet

Date

Scale

US FISH & WILDLIFE SERVICE

PELICAN ISLAND NWR,

PROPOSED RESIDENCE QUARTERS

& ROADWAY EXTENSION

Project Name and Address

Firm Name and Address

HYDRA ENGINNEERING &CONSTRUCTION LLC.

36 JASPER THOMAS ROAD

CRAWFORDVILLE, FL 32327

(850) 926-2593 PHONE

(850) 926-9257 FAX

No. Revision/ Issue Date

Lyman Davidson Dooley, Inc.

FOR CONSTRUCTION

1/4" = 1'-0"

A10105/09/2016

4R-FLA-400-XXX

DIMENSIONED FLOOR

PLAN

1/4" = 1'-0"1 DIMENSIONED FLOOR PLAN

WALL SCHEDULE

MARK SYMBOL DESCRIPTION

1 1/2" EXT. CLAPBOARD

AIR BARRIER WRAP

1/2" OSB SHEATHING

5 1/2" RIGID FOAM INSULATION

1/2" OSB SHEATHING

5/8" GYP. BOARD

2 5/8" GYP. BOARD

3 1/2" WOOD FRAMING

5/8" GYP. BOARD

3 5/8" GYP. BOARD

5 1/2" WOOD FRAMING

5/8" GYP BOARD

4 EXT. CLAPBOARD

AIR BARRIER WRAP

1/2" OSB SHEATHING

5 1/2" RIGID FOAM INSULATION

1/2" OSB SHEATHING

5 1/2" WOOD STUD

5/8" GYP. BOARD

5 3/4" STUCCO

7 5/8" MASONRY

6 5/8" GYP. BOARD

1/2" OSB BOARD

3 1/2" RIGID FOAM INSULATION

1/2" OSB BOARD

5/8" GYP. BOARD

N

1. ALL OPENINGS IN EXTERIOR WALLS ARE DIMENSIONED FROM

EXTERIOR FACE OF SIPS TO CENTERLINE OF OPENING UNLESS NOTED

OTHERWISE.

2. ALL OPENINGS IN INTERIOR PARTITIONS ARE LOCATED FROM

CENTERLINE OF OPENING TO FINISH FACE OF WALL UNLESS NOTED

OTHERWISE.

2 4 810

1/4" = 1' Graphic Scale

1 REVISION #1 VE CHANGES 1/29/16

2 95% USFWS COMMENTS 4/29/16