EML500 series General Specifications
GS 80880M01E 13th
EML500
Electromagnetic Log
General The EML500 series electromagnetic log confirms to the technical requirements for the performance standard determined by IMO Resolution A824(19) and MSC.96(72) also meet type approval issued by the Transport Ministry of JG
Certificate number of type approval
- JG : No. 3795
- MED (Wheel mark) : MED-B-6816
Features
1) Small size and light weight compared ordinary models.
2) The length of cable between the sensor and the master unit can be extended maximum 300m by adoption of the preamplifier built.
3) Full provision of various external interfaces
- Pulse output (Photo coupler / contact)
- Digital signal (NMEA0183)
- Analog signal (OV to 5V DC / DA to 20mA)
- Alarm contact output and Digital 1/F form GPS
4) Reduction in the number of parts by employment of highly integrated circuits including microprocessor, and has no moving parts, thereby achieving high reliability.
5) Provision of small size and light weight master indicator for indication of speed and distance, and can be operated by the master indicator. Milepost calibration etc., thereby, installation place of master indicator is not limited.
6) Variety of sensors available to meet various instillation requirements. A dual-axis sensor can measure not only the longitudinal, speed but also the transverse speed.
7) Built-in self-diagnostic function.
8) All indicators can be driven by input signal (NMEA0183) from
GPS.
General specification
- Measurement subject : Ship's water speed and distance
- Measurement principle : Faraday's law of electromagnetic induction
Performance specification
- Measurement range
Speed -4kt to +20kt (Note 1
-5kt to +25kt (Note 1
-7kt to +35kt
-10kt to +50kt (Note 2
(Note 1 MED is attended in case of Single-axis system (range of "-4kn to 20kn" or "-5kn to 25kn").
(Note 2 Additional engineering is required concerning the installation of the sensor.
Trance verse speed : 0kt to ±6.5kt (for Dual-axis)
Distance : 0nm to 9999.99nm
YOKOGAWA+
Yokogawa Denshikiki Co., Ltd.
- Single-axis sensor (right)
- Dual-axis sensor (right)
- MHR130/LR525 Speed indicator
- LR523 Master indicator (left)
- L T501 Master unit (left)
Dictation of ship movement: 0 to 359 deg., clockwise from the bow-to-stern line (fixed to O deg. if the resultant speed is 0.5kt or less)
- Measuring accuracy
Speed - Measurement accuracy
2% of the speed of the ship, or 0.2 knots, whichever is greater.
- Indicate accuracy
±0.15kt with respect to standard signal input
(±0.25kt or less if the measuring range is above 50kt)
Distance ±0.2nm/h or ±2.0% max., whichever is larger
Direction of ship direction : ±2.5 deg. max.
- Response speed
Variable up to 2min for a O to FS-step input (0% to 90% response)
- Restriction of the cables between each equipments
N N N 0 N N N
> " " " L 1 = 200m Max.
L2 = 200m Max.
a: a: a:
L3 = 250m Max.
Junct ion box
Note) The cable specification with Cross specification : 0.5mm2
Resist ance : 30Q/km
2013.04 13th (YDK) 2004.11 2006.04 2009.09
L4 = 50m Max.
Maker supply cable
10th (YDK) 11th(YDK) 12th(YDK)
GS 80BBOM01 E
2002.12 7th (YDK)
2004.05 Bth (YDK)
2004.10 9th (YDK)
Environmental conditions
- Ambient temperature : operating -15°C to +55°C
- Humidity
-Vibration not operating -20°C to +6D°C
95% RH (no dew condensation around)
5Hz to 12.5Hz ±1.6mm
12.5Hz to 25Hz ±0.38mm
25Hz to 50Hz ±0.1mm
-EMC:Acc.to IEC 60945
System configuration diagram
- Noise of power source line :
Not failure in the state put on the pulse 100/400nsec, 1500V during three minutes.
- Insulation resistance :
At last 1 DO using a 500V megger (Excluding electronic circuit)
- Withstanding voltage
1500V AC for 1 min. (Excluding electronic circuit)
Analog speed indicator Assist Monitor
(MHR112)
(Option)
Universal data display
(MHR120)
(Option)
Master indicator
(LR523)
(MHR130) (LR525)
i)o,<i lleHL: : 1~1 ·::~~.
Ship's Speed
(NMEA0183)
~S J>------1 .. ~I
Ship' s power supply 100V to 115V AC or 200V to 230V AC
Serial signal (YDK format:)
I t Dimmer box
(MKD010)
Serial s ignal (NMEA0183 format)
Analog signal (Voltage signal) : 4 circuit (OV to 5V DC or 1V to 5V DC) _.
Analog signal (Current signal) : 2 c ircuit (QA to 20mA or 4 to 20mA) ~
Pulse signal (contact signal) t J
Dimme r box
(LD001A)
VDR
ECDIS
I
_1_
:1···
I Dimmer box
(MKDD02)
l
Junction box
(LN052)
_(_2o_o_pl_n_m) _________ __..,_I RADAR etc.
m w
EML500-HD1 (Single-axis)
Cll 35F Double-bottom type
Pulse signal (Photo coupler ) (200p/ nm)
EML500-HS1 (Sigle-axis)
Cll 35F Single-bottom type
Sea wat er valve , / (LVOJJ) +-k Sea water valve
/ (LV033)
Cll 35 sensor Cj) 35 sensor
(LS501 ) (LS531)
Rodmeter
(LS591)
Yokogawa Denshikiki Co.,Ltd.
ARPA
GYRO COMPASS
AUTO PILOT
INS
RADAR
True wind direct ion and speed indicat or
EML50 HV1/HV2
(Single / Dual axis)
Cll 70F Single-bottom type
Sea water valve
(LV071A)
Cll70 sensor
EML500-FA1/FA2
(Single / dual axis)
Cll48F Single-bottom type
Sea water valve
(LV052)
Cll48 sensor
(LS571 : Single axis) (LS572 : Dual axis)
(LS541 : Single sxis) (LS542 : Dual axis)
GS80B80M01 E 13th 2013-04
Component models of EML500 EML500 is composed of Master unit, Master indicator and Sea-bottom (with sensor).
And if it is necessary, combined with speed indicator and environ equipments.
Basic system models According to type of Sensor unit, basic system model is set.
Component Models : EML500-DDD
... I __ ""')"" Sensor unit code
~e
EML500-DDD
Pr HS1 HD1 HV1 FA1 HV2 FA2
Master unit LT501 0 0 0 0 0 0
Master indicator LR523 0 0 0 0 0 0
Speed indicator (Single-axis) MHR130 0 0 0 0
Dimmer box MRD010 0 0 0 0
Speed indicator (Dual-axis) LR525 0 0
Dimmer box LD001A 0 0
Junction box LN052 0 0 0 0 0 0
LS531 0
LS501 0
LS571 0
Sensor
LS541 0
LS572 0
LS542 0
Rodmeter LS591 0
Sensor cable LS503 0 0 0 0 0
LV033 0 0
Seawater valve LV071A 0 0 ., LV052 0 0 ·c:
Seawater valve flange LV904 0 ...
"' Protection tube LV905 0 C:
" en Mounting LV902A-1 D !::,.
plate for LV902A-20 !::,.
seawater LV902A-3D !::,.
valve LV902A-40 !::,. !::,.
LV902A-5 0 !::,. !::,.
LV910 !::,. !::,.
LV901-1 D !::,.
LV901-20 t:,.
Zinc plate
LV901-3 0
(Note) (Note)
Installation Single- Double- Single- Single- Single- Single-
Sensor type bottom bottom bottom bottom bottom bottom
Standard length 7mm 13mm 7mm 13mm installation 50mm 50mm or or or or of protrusion 57mm 73mm 57mm 73mm iili ~
MRD010/ MRDOl 1
LD001A/ LD002
<!> 35sensor with cable
Only sensor element <!> 35
<!> 70 sensor (Single-axis)
<!> 48 sensor (Single-axis)
<!> 70 sensor (Dual-axis)
<!> 48 sensor (Dual-axis)
Not including the sensor
For sensors <!> 35
For sensors <!> 70
For sensors <!>48
Note: For Flash-mounted unit (Unnecessary for a protruding unit)
Length from bottom plate
Note : Items marked with a " I::,. " are ordered from the shipbuilder as standard.
Yokogawa Denshikiki Co.,Ltd. GS80B80M01 E 13th 2013-04
Engineering specification
- Power
1 DOV to 115V AC or
200V to 230VAC ±10% 50/60Hz ±6%
(Selectable by the jumper setting in the power supply unit)
- Power consumption
BOVA
- Input signal
- Input the detected voltage at sensor
0.242mA/knot (from sensor)
- Input from GPS (for back-up by GPS)
Data foimat of GPS input can be set by Master indicator.
Connection units : GPS, Other speed sensor
Transmission format: Asynchronous serial data signal
Transmission rate : 4800bps
Data character Start bit 1 bit
Data bit 8 bit
Stop bit 1 bit
Parity None
Data foimat
Recommend format : based on IEC61162-1, VTG, VBW, VHW and etc ...
Header character : 6 ASCII letter
(Example : $GPVTG and etc ... )
Position of speed data:
Set data based on the location of commas.
Checksum
Input circuit
- Output signal
: Select Use or Unused
: Photo coupler
- Analog speed signal : Voltage output (2 circuit)
Output level : Select able from OV to 5V or 1 V to 5V
Output volU!ge Output cu rrent
5V --------------- 5V --------------
1V
-~O,-kt "',a O~V-----~,"~II k,-t ~= SVShip' s speed -~o,"""'t •C.,l,....V ----.=,"=n k~t .~ SY Ship' s speed
Output voltage Output current
SY -------------- 5V --------------
1V Ship' s speed I Ship' s speed
- Ful"°lkt"""•~OV.,+------~,,~,, ,,...., ~= 5V - Fu1·1°" , ,- . ~, v.,+-----.=,,~11,....,,~= 5V
Yokogawa Denshikiki Co.,Ltd.
- Analog speed signal : Current output (4 circuit)
Output level : select able from OmA to 20mA or 4mA to 20mA
Out.put voltage Output current
20mA --------------- 20mA ---------------
4mA
S hip' s speed S hip' s s peed -=Ok-t a"',O-mA~---.~,"~11 k-'-t a~,OmA -=,,-, a'-,4m~A----+~Fu~ll k-'-t a~2~0mA
Output voltage Output current
20mA ---------------
- Distance pulse output : Photo coupler type (8 circuit)
Capacity Voltage between terminals 24V max
Sh ink current 5mA max.
Dark current 50µA max.
(at 24V between terminals)
Pulse weight 200P/nm
- Distance pulse output: Relay contact type (2 circuit)
Capacity Rate loads 30V DC, 1A
(resistance load) 30V AC, 0.5A
Minimum appliciate load 1 OmV DC, 1 OµA
Chattering
Pulse weight
1msecmax.
200P/nm
- Serial signal output
Serial signal : based on NMEA0183 (Ver.2.3)
Transmission format : Asynchronous serial data signal
Transmission rate : 4800bps
Transmission period : 1sec
Transmission length : 1.2km
Data character Start bit 1 bit
Data bit 8 bit
Stop bit 1 bit
Parity None
Connected Device : RADAR, ECDIS and etc ..
Output circuit : EIA RS-422-A
SN75172 t')SHILD
- Data format (based on NMEA0183)
( EM.Log Software version : "P" )
Output sentence is possible changing by DIP SW.
<NMEA Ver 2.0 setting : Normally setting>
VBW sentence
11$1TvlM!TvlslwlToAoA If'""' ; '""'I~;::-~':';:
'----------Checksum identifier
'----------Data ~-----------Talker identifier VBW : Dual ground / water speed
~-------------Talker identifier : VM EM LOG
~--------------Header
Data block format
1) for single-axis
I, IY- IJO'IIO'l · l10 ·l10 'I, I, I a I , I , I, 1v1 y y
Longitudinal A:data valid V:Data invalid water speed (kt) V:data invalid Fixed data
2) for dual-axis
I , IY-110'1 1001 · !io-•!io-'! · IY-l10·lwl . !io-•!io-'! , I a I , I , I , IV I y y
Longitudinal Transverse A:data valid V:Oat a invalid wate r speed (kt) water speed (kt) V:data invalid Fixed data
3) When the GPS speed is selected
I , IY- IJO'l 100l -lrn-'l10-'I , I , I a I, IO l10·l100l -l10-·110-1 , 1.1 a I y y
Longitudinal A:dat a valid Longit udinal V:Data invalid water speed (kt ) V:data invalid ground speed (kt) Fixed data
4) When the system error is detected
1-1-1 -lvl . 1. I -!vi
5) When the ROM/RAM error is detected
Sentence is not output.
-AN : A= Data valid
V = Data invalid
- Range of data
Water speed : -13.00kt to 65kt
Ground speed : 0.00kt to 99.9kt
VHW sentence
11$1Tv!M!Tv!H!w!TDATA If suM1 I suM2 I~~~~:::::
'----------Check sum identif ier
'----------Data '------------Talker identifier VHW: Water speed and heading
~-------------Talker identifier: VM EM LOG
~--------------Header
Data block format
1) When the Log speed select (single axis and dual axis)
1-1 · 1 · 1. 1. l.10'1 1001 : l10-·l10-j . I~) . 1- lj Water Speed K (k ) km/ h
(kt) not s t
2) When the GPS speed select
1. 1.1 . 1 .1 , 110'1 1001 -l10 'l101 . 1 NI .1 .1 KI y y
Ground Spee d K t (kt) km/ h
(kt) no s
3) When the system error is detected
1.1.1 . 1.1 . 1. !NI .1.1K1
Yokogawa Denshikiki Co.,Ltd.
4) When the ROM/RAM error is detected
Sentence is not output.
- Range of data
Water speed : 0.00kt to 65kt
O.OOkm/h to 120.38km/h
VLW sentence
~---------Checksum ident ifier
11$1TvlMITvlLlwlToAoA If'""' I'""' I~;;:;::;
~---------Data
~-----------Talker identifier VLW : Distance traveled through the water
~-------------Talker ident ifier: VM EM LOG
~--------------Header
Data block format
1) at normal operation
I , l.103!1021101110°1.110+1 . IN I , l.10'!102!101 !1001.1w-•l1 0-j ' IN I . ..
Total cumulative distance (nm) Distanc e s ince rest (nm)
2) When the system error is detected
I, I, INI ' I, INI
3) When the ROM/RAM error is detected
Sentence is not output.
- Range of data
Total cumulative distance : 0.00nm to 9999.99nm
Distance since rest : 0.00nm to 9999.99nm
- Checksum
Checksum is the 8-bit exclusive-OR (no start or stop bits) of all characters in the sentence, including "," delimiters, but not including the "$" and the "*" delimiters.
<NMEA Ver 2.3 setting>
VBW sentence
11$1Tv1M1Tv1B1w1TDA,A Ir·· I'""' I~:.-:-.-::
'----------Check sum identifier
'----------Data ~-----------Talker identifier VBW Dual ground / water speed
~-------------Talker identifier : VM EM LOG
~--------------Header
Data block format
1 ) for single-axis
I , 17-110'1•00! . 1,0-,lwj . 1-I~) .. 1. 1-1:;) . I . 1:;1 . 1- 1:;1 Longitudinal A:data vahd V:Data invalid water speed (kt ) V:data invalid Fixed data
2) for dual-axis
I -l'.!-"l•0·l·00! · l10 ·l10 j . l'.!-"l 10·l•00!. f0 ·l10 j -I~ . I -I -!VI .1.1v1 -I -!VI Longitudinal Transverse A:da~alid y y y V:Data invalid water speed (kt) water speed(kt) V:dat a invalid Fixed data
3) When the GPS speed is selected (single-axis)
1-M0·l·00!, 110-'lwj -I -lc:,1-1 ° l'°'I'""!, lw'l10·j -1 -lj , I, 1v1 , I, 1v1 Longitudinal A:data valid Longitudinal A:data valid y y V:Dat a invalid wat er speed (kt) V:data invalid ground speed (kt) V:data invalid Fixed data
4) When the GPS speed is selected (dual-axis)
4) When the ROM/RAM error is detected
Sentence is not output.
- Range of data
Water speed : 0.00kt to 65kt
O.OOkm/h to 120.38km/h
Ground speed : 0.00kt to 99.90kt
O.OOkm/h to 185.01km/h
VLW sentence
- Check sum identif ier
$ ITvlMITvlLlwlToA" If"'"' I"'"' I~;;:::~;
'----------Data
'--------------Talker identifier VLW: Distance traveled through t he water
'--------------Talker ident if ier: VM EM LOG
~--------------Header
Data block format
1) at normal operation
, 10' 102 101 100 • 10-110 , N , 10' 102 101 100 • 10-1 10- , N
Total cumulative distance (nm) Distance since rest (nm)
2) When the system error is detected I, l~l"'I"'! l10 l10 j ' l~H·if! H10 I, l•I, 1° 110'110 !, fa H, I,~ . I, 1v1, I, 1v1 l ongitudinal Transverse A:da~ valid Longitudinal A:da~alid ~ V:Data invalid I - 1. 1. 1. I water speed (kt ) wat er speed(kt ) V:data invalid ground speed(kt) V:data invalid Fixed data
5) When the system error is detected
I, I, I, 1v1 . I, I, 1v1. I, 1v1 . I, 1v1
6) When the ROM/RAM error is detected
Sentence is not output.
-AN : A= Data valid
V = Data invalid
- Range of data
Water speed : -13.00kt to 65kt
Ground speed : 0.00kt to 99.9kt
VHW sentence
$ ITvlM ITv !H!W!TDA;> If '""' I '""' I~ ;~~::':
- Check sum ident ifier
'------------Data
'--------------Talker identifier VHW: Wat er speed and heading
~-------------Talker identifier : VM EM LOG
~--------------Header
Data block format
1) When the Log speed is selected
I , I , I, I , I , l10'l100l · l10 'l10 'I , IN I , l102l101l100l -l10 ·l10 1, I KI y y
Water Speed K (k ) Water Speed
(kt) nots t (km/ h) km/ h
2) When the GPS speed is selected
I , I, I, I , I , l10'l 100I · l• 0-·l10·1 , IN I , l10'110'l 100I · l10··l10·1, I KI y y
Ground Speed K (k ) Ground Speed
(kt) nots t (kt) km/ h
3) When the system error is detected
I -I, I, 1. I -I- I -I -I
Yokogawa Denshikiki Co.,Ltd.
3) When the ROM/RAM error is detected
Sentence is not output.
- Range of data
Total cumulative distance : 0.00nm to 9999.99nm
Distance since rest : 0.00nm to 9999.99nm
- Checksum
Checksum is the 8-bit exclusive-OR (no start or stop bits) of all characters in the sentence, including"," delimiters, but not including the "$" and the "*" delimiters.
- Speed limit output (2 circuits)
Contact : At state of speed limit "Close" (standard)
At state of speed limit "Open"
(Selectable by Dip.SW 9-2(off: close, on: open))
Capacity Rate loads 30V DC, 1A
Setting
(resistance load) 30VAC, 0.5A
Minimum appliciate load 1 OmV DC, 1 OµA
Chattering 1 msec max.
: The higher or lower speed limit can be set by
Master indicator.
-Alarm contact output (2 circuits)
Contact : At abnormal "Close" (standard)
At abnormal "Open"
(Selectable by Dip.SW 9-3(off: close, on: open))
Capacity Rate loads 30V DC, 1A
(resistance load) 30VAC, 0.5A
Minimum appliciate load 1 OmV DC, 1 OµA
Chattering 1msecmax.
Failure alarm - ROM/RAM error
- Low battery (less than 2.1V)
- AID converter error
- GPS input error
- Communication error between Master unit and Master indicator.
Comportment equipment specification
- Master unit LT501
Receives and converters speed data signals from the sensor. Then transmits the speed and distance to external devices in various signal forms.
- Wiring position : Coaming of under or back
- Installation : Wall or flush mounted type
- Master indicator LR523
Receives digital signals from the master unit, and displays the speed and distance. Both the display and operation panel are on the front of the master indicator. Set data are sent to the master unit in the form of digital signals, and placed in the memory.
- Display function
The speed and distance are displayed with digital by LED indicator.
1) Indicate of the Speed and Distance
Speed : (-)CD Ckt
Distance : ITIIJ Dim
2) Indicate of the trip distance
Trip distance : ITIIJ Dim
3) Indication of the longitudinal transverse speed
(for dual-axis) longitudinal speed : (-)CD Ckt
Transverse speed : S/PD Ckt
4) Indicating of the resultant speed and detection
(for dual-axis)
Resultant speed : (-)CD Ckt
Direction : ITil:leg (relative direction)
5) Indication of GPS speed data
It is indicated ship's speed, total distance traveled and trip distance by speed data from GPS.
6) Indication of alarm
The error messages detected by self diagnostic function are indicated.
- In the first stage adjustment, manual key-in and maintenance
Possible to set manual speed, zero adjustment, milepost measurement, and also to confirm of various data.
- Dimmer LED : LED lamps are added and subtracted
- Input signal by mm buttons.
: Digital signal(NMEA0183)
Input voltage 24V DC
- Wiring position : Coaming of under or back
- Installation : Desk-top, Wall mount or Flash mount
- Construction : Water resist type
- Junction box LN052
The junction box is used for connection between sensor and master unit. And it is connected by maker supply cable and ship-builder supply cable.
- Installation :Wall mount
- Wiring position : Ground with water resist
Yokogawa Denshikiki Co.,Ltd.
- Speed indicator MHR130(Sinqle-axis) / LR525 (Dual-axis)
This is a large analog indicator with an outside diameter of
180mm.
The indicative variation are speed, longitudinal/ transverse speed (for dual-axis) and resultant speed /direction. And the scale boards are prepared 18 kinds include each measurement range.
- Power supply : 24V DC 0.3A (7.5W)
- Capacity : 4 circuits max.
However, the forth is necessary to have the power supply of 24V DC from external.
- Input signal : Digital signal
- Illumination : EL board or LED illumination
- Dimmer : Built-in or external
- Wiring position : Back part
- lnstauration
- Construction
: Flash mount or Wall mount
: Type of water resist
- Dimmer box MKD010/LD001A
For MHR130 / LR525
- Power supply : 1 OOV to 115V or 200V to 230V AC
- Wiring position : Corming
- lnstauration : Flash mount or Wall mount
Sea-bottom (Sensor)
- HS1 type Using the <1>35 sensor, and installed at single or double bottom of ship. Standard length of protraction is 50mm.
- Sensor : Outside diameter : <1>35, length : 400mm with cable (7m/15m)
- Seawater valve : 40A JIS5K Gate valve
- HD1 type Using the<l>35 sensor, and installed with penetration double bottom. Seawater valve is installed on inner sea-bottom.
Standard length of protraction is 50mm.
- Sensor : Outside diameter : <1>35 with rodmeter
(connected by connecter)
- Seawater valve : 40A JIS5K Gate valve
- Protection tube/seawater valve :
Water resist that the sensor and rodmeter go through double bottom.
- FA 1 /FA2 type Using the<l>48 sensor, and installed at single bottom of ship. Standard length of protraction 1 s 13mm or 73mm. FA2 is for dual-axis.
- Sensor : Outside diameter : <1>48, length 345mm
- Seawater valve : 50A JIS5K ball valve
- HV1/HV2 type Using the<l>70 sensor, and installed at single bottom of ship. Standard length of protraction is 7mm or 50mm. HV2 is for dual-axis.
- Sensor : Outside diameter : <1>70, length 510mm
- Seawater valve : 75A JIS5K ball valve
Outline and Type No. and Suffix code Master indicator (Wall mount)
LR523-WO 0-1-0
"' .I I I I, "' L J
GBBBEl3El3El3 Ge 888El3$El3
I
MOUNTING DIMENSION
150±0.5
_l
4-MS or 6 HOLE
Master indicator (Flash mount)
LR523-D00-1-0
PANEL CUT
HOLE
4-C6.5
Master indicator (Flash mount)
LR523-FO 0-1-0
I I e
21s
200+0.5
I I cpoo :xpcp=
PANEL CUT
200:!:0.5
HOLE
4-M5 or cb 6 HOLE/
Yokogawa Denshikiki Co.,Ltd.
MODEL LR523 - W
MASS 1 . 2 kg
COAMING r/>25
TERMINAL CONNECTIONS
24V C
NMEA0183 INPUT
NMEA0183 OUTPUT
MODEL LR523-D
MASS 1 . 3 kg
TERMINAL CONNECTIONS
M ODEL LR5 23-F
MASS 1 1 kg
TERMINAL BOARD
COAMING r/>25
TERMINAL CONNECTIONS
24V DC
NMEA0183 INPUT
NMEAOl83 OUTPUT
Master indicator LR523-X1 • • • X5/ 0ption Type No. Suffix code Note
LR523 .................... For EML500
Style -D Flush mount
-F Flush mount (with bezel)
X1 -w Desk top type or Wall mount
System
I 1 Single-axis
X2 2 Dual-axis
Rule / Name plate 1 None / Japanese & English
2 JG / Japanese & English
3 JG / Japanese
4 None / English
5 MED / Japanese & English (Note 1)
X3 6 MED / English (Note 1)
Color X4 1-1 YDK Standard (CC24 brown)
Name plate -1 HS1
-2 HD1
-3 HV 1
-4 HV 2
-5 FA1
X5 -6 FA2
Option I / CHS Name plate in Chinese
(Note 1) MED is attended in case of System X2 = 1 (Single-axis).
Master unit (Wall mount)
LT501-WDDDDD-D
D D D D
- -- - : __ , 0
EARTH TERMINAL
COAMING 30 x 100 m
Master unit (Flash mount)
LT501-FDDDDD-D
1·
270±0.5
• 1
D D D D
EARTH TERMINAL
Yokogawa Denshikiki Co.,Ltd.
3.2
4- 7 HOLE
MODEL LT501-W
MASS 4 . 9 kg
COAMING 30 x 100
MOUNTING DIMENSION
210±0.5
1-
-1-t I
I
4- M6 or ¢ 7HOLE
MODEL LT501 - F
MASS 6 . 4 kg
11 6
TERMINAL BOARD
COAMING 30 1t 100
PANEL CUT
270±0.5
254.5
0 ~ tl -
"' "' HOLE
4- M6 or 7 HOLE
LT501-Y Master unit
(Wall mount : with corming plate)
LT501-YDDDDD-D
= = = = == c:::::J = :;i D "' D D
D = D = = D
COAMING 30 x 100
Terminal drawing
<D®@@
ANALOG SPEED OUTPUT
OmA to 20mA or 4mA to 20mA
PHOTO OCUPLER OUTPUT
200Pulse/n mile
DIGITAL SPEED OUTPUT
NMEAOt83(VBW)
@GPS BACK-UP INPUT
CONTACT OUTPUT
200Pulse/n mile
@ SHIP'S POWER SUPPLY
MODEL LT5 01-Y
d +--i
MASS 5 . 1 kg
TERMINAL BOARD
210±0.5
I
-1-
I 4-M6 or ¢ 7 HOLE
ALARM CONTACT OUTPUT FOR SPEED LIMIT
13@
ANALOG SPEED OUTPUT
OV DC to 5V DC or 1V DC to 5V DC/FULL RANGE
ALARM CONTACT OUTPUT FOR SYSTEM FAIL
@ SPEED INDICATOR OUTPUT
@ MASTER INDICATOR OUTPUT
@ JUNCTION BOX INPUT/OUTPUT
@)AC POWER FOR OUTPUT
DC POVVER FOR OUWUT
Master unit LT501-X1 • • • X7 /0ption Type No. Suffix code Not e
LT501 .................... For EML500
Style -F Flush mount
-w Wall mount x, -Y Wall mount (with coaming plate)
System 1: Single-axis
X2 Dual-axis (Note 1)
Ship' s power , 100V AC 50/60Hz 1 Cf>
2 110V AC 50/60Hz 1 Cf>
3 115V AC 50/60Hz 1 Cf>
4 200V AC 50/60Hz 1 Cf>
X3 5 220V AC 50/ 60Hz 1 Cf>
Measurement range 1 - 4kn to 20kn
2 - 5kn to 25kn
3 - 7kn to 35kn
4 - Bkn to 40kn
5 -1 Okn to 50kn (Note 2)
X4 6 -1 3kn to 65kn (Note 2)
Rule / Name plate 1 None / Japanese & English
2 JG / Japanese & English
3 JG / J apanese
4 None / English
5 MEO / Japanese & English (Note 3)
X5 6 MEO / English (Note 3)
Color 1 YDK Standard (CC24 brown)
2 Munsell 2.5G7 / 2
X6 3 Munsell 7.5BG7/ 2
Name plate -1 HSl
- 2 HD1
-3 HVl
-4 HV2
-5 FAl
X7 -6 FA2
Option / AN1 Alarog output (Connect LR522)
/ AN5 Analog out.put
/ ANF1 Analog output
/ ANF5 Anarog output (OV to 5V DC output)
/CHS Name plate in Chinese
/GPS External speed signal input (Note 4)
(Note 1) In case of dual-axis, transverse speed may not be able to the mounting position of sensor.
(Note 2) About 50160kt correspondence, additional e ngineering is required concerning t he installat ion of the sensor.
(Note 3) MEO is attended in case of System X2 = 1 (Singte- axis) and X4 = 1 (-4kn to 2otsn) or X4 = 2 (-5kn to 25kn)
(Note 4) Please append external speed s ignal (NMEA0183) format with order sheet.
Options : Analog output list
/AN5
(j)
/ AN1
(2)
/ AN F5
:Ji
/ANF1
l2J ~··-1~~ ~ ... Okt = OV +Full kt = 5V Ol<.t = 1V +Fullkt =5V
Omom ,,_co,o LJO"~~,cacc,ac I
.•.•. 1V i Ship0 sspeed : i Ship0 sspeed
- Fullkt-OV +Full kt - 5V - Full kt= 1V +Fullkt =-5V
Osco• ""'" ~ o;:;:~~""' '
4mA !
Ship. s speed : : Ship " s sp~ed
- Full ~l OmA +Full kt 20mA -Full kl = 4mA +Full kt = 20mA
Yokogawa Denshikiki Co.,Ltd.
Junction box
LN052-WDDD-D
MOUNTING DIMENSION
MODEL LN052
MAS S 0 . 8 kg
TERMINAL BOARD
TERMINAL CONNECTIONS
FROM
MASTER UNIT
A : OmA to 20mA - C,D t-15V. - 15V
E.F.G : 24V DC
TO SENSOR
A : OmA to 20mA C.0 : +15V, - 15V
E.F : 24V DC
Junction box LN052-X1 · · · X5/ 0 ption Type No. Suffix code Not e
LN052 .................... For EML500/ 50
Style X l -w Wall mount
Rule / Name plate 1 None / Japanese & English
2 JG / J apanese & English
3 JG / J apanese
4 None / English
5 MED / J apanese & English (Not e 3)
X2 6 MED / English (Note 3)
Color 1 Munsell 2.5G7 / 2
X3 2 Munsell 7.5G7/ 2
Grand size 1 20c
2 25a
3 25b
X4 4 25c
Name plate -3 HSl
-4 HD1
-5 HV1
- 6 HV2
-7 FAl
X5 - 8 FA2
Option I / CHS Name plate in Chinese
Analog indicator (Wall mount)
MHR130-SPD-WO 0-0 0 0-0 0 0-0 0-0 0 0
Y-View (Back side)
Analog indicator (Flash mount)
MHR130-SPD-FO 0-0 0 0-0 0 0-0 0-0 0 0
-...-Y
4-</>5.5M5
Y-View (Back side)
Yokogawa Denshikiki Co.,Ltd.
Scale plate list
From -4kt to 20kt From -5kt to 25kt
From - 7kt to 35kt From -10kt to 50kt
Analog indicator MHR130-X1 • ··X12/0ption Model Suffix Specification
MHR130 .......................... Analog indicator
Function X1 -SPD Speed indicator
Style 1-F
Flash mount
X2 -W Wall mount
Cable inlet 1
1:
Coaming Note 1
X3 Grand Note 2
Cable inlet 2 0 Not use
1 Coaming
X4 2 Grand
Power supply 1-1
100-220VAC,50/60Hz, 1 </J
X5 -2 24VDC (Non isolate)
Dimmer 0 Without dimmer
1 Built in dimmer
2 DC dimmer supply by YDK
3 DC dimmer supply by YARD
X6 4 100V AC dimmer supply by YARD
Back.light color 0 Non
1 Umber
X7 2 Green
Scale range -S20 -4kn to 20kn
-S25 -5kn to 25kn
-S35 -7kn to 35kn
X8 -S50 -1 Okn to 50kn
Input signal 1-21 Speed signal (PYDK, 4800bps)
X9 -22 Speed signal (PYDK, 9600bps)
Standards -0 Not applicable
-1 JG
X10 -2 MED (wheel mar1c)
Name plate
1:
Japanese and English
X 11 English
Paint color 1 Munsell 0.8Y2.5/0.4 (LAMP BLACK)
2 Munsell 2 .5G7/2
X12 3 Munsell 7.5BG7/2
Option IC Chinese name plate
/ HS1 For HS1 system
/ HD1 For HD1 system
/HV1 For HV1 system
I FA1 For FA1 system
Note1} If selected X3 = 1 Coaming, will you select X4 = 1 Coaming.
Note2} If selected X3 = 1 Grand, will you select X4 = O Non or 2 Grand.
MRD010 Dimmer box
MRD01 O-W-20F-D DD D
4-
<O
CABLE GRAND
20f (20a to 20c)
Dimmer box MRD010-X1 ···XS Model Suffix
MKD010
Style X1 -W
Cable inlet X2 l-20F
Standards 1; X3
Name plate I: X4
Paint color I: X5
Yokogawa Denshikiki Co.,Ltd.
e
Specification
Dimmer box
Wall mount (Water proof)
Glands 201
Not applicable
MED (wheel mark)
Japanese and English
English
Munsell 2.5G7/2
Munsell 7.5BG7/2
MRD011-N Dimmer unit (Dimmer only)
MRDOl 1-NDD-D
MRD011-F Dimmer unit (Flash mount)
MRD011-ND0-D
Dimmer unit MRD011-X1 · · ·X4 Model Suffix Specification
MRD011 ................. .. ....... Dimmer unit
Style -N Dimmer only
X1 -F Flash mount
Standards I~ Not applicable
X2 MED (wheel mark)
Name plate I: Japanese and English
X3 English
Paint color 1 · 1
Note 1 Munsell 0.8Y2.5/0.4 (LAMP BLACK)
X4 .4 Note 2
Note 1) If you select X1 =-N, Please select X4=-1.
Note 2) If you select X 1 =-F, Please select X4=-4.
Black
Analog indicator (Wall mount)
LR525-WD D-D DD D D-D
MOUNTING DIMENSION
120±0.5
4- MlO or dJ 11 HOLE
¢JO HOLE
Analog indicator (Flash mount)
LR525-FDD-DDDDD-D
4- M6 or
Yokogawa Denshikiki Co.,Ltd.
MODEL LR525 - W
MASS 4 . 1kg
~.4S m ~
TERMINAL BOARD
CABLE INLET 25
MGNETIC COMPASS SAFE DISTANCE LABEL
TERMINAL CONNECTIONS
24V DC
MODEL LR525-F
MASS 3 . 8 kg
26 99
TERMINAL BOARD
CABLE INLET ¢ 25
BEL
TERMINAL CONNECTIONS
I
Scale plate list resultant speed /direction longitudinal / transverse speed
Built-in dimmer EL boa rd illumination
24V DC
Separate dimmer EL board illumination
TERMINAL CONNECTIONS
r
Built - in dimmer LED illumination
TERMINAL CONNECTIONS
NMEA0183 INPUT
'------:1 24V DC
Separate dimmer LED illumination
TERMINAL CONNECTIONS
NMEA0183 INPUT
·------:· 24V DC
Speed indicator (Dual axis) LR525-X1 • • • X9/ 0ption Type No. Suffix code Not e
LR525 .................... For EML500 (Dual-axis)
Style -F Flush mount
X1 -w Desk top type or Wall mount
Measurement range 1 - 4kn to 20kn (Note 1)
2 - 5kn to 25kn
3 - 7 kn t o 35kn
4 - Bkn to 40kn
5 -1 Okn to 5Dkn
X2 6 -13kn to 65kn
Scale plate 1: Longitudinal / Transverse s peed
X3 Result ant speed / Direction
Illumination -A LED Orange color
-B LED Green color
-G EL board Green cok>r
-N Illumination not use
X4 -R EL board Orange color
Dimmer / Power supply 1 External/100V to 115V AC 50/60Hz 1 <P
2 (Note 2) Built-in / 100V to 115V AC 50/ 60Hz 1 <P
3 External/ 200V to 230V AC 50/ 60Hz 1 <P
4 (Note 2) Built-in /200V to 230V AC 5D/ 60Hz 1 <P
5 External/ LED illuminat ion
6 Built-in / LED illumination
X5 N Illumination not use
Wiring position 1: Cormingc/>2S
X6 Grand (Note 3)
Rule / Name plate 1 None / Japanese & Engtish
2 JG / Japanese & English
3 J G / J apanese
X7 4 None / Englis h
Color 1 YDK Standard (CC24 brown)
2 Munsell 2.5G7/ 2
XB 3 Munsell 7.5BG7/ 2
Name plate 1-1
HV 2
X9 -2 FA2
Option I / CHS Name plate in Chines e
(Note 1) Case of Res ultant s peed / Direction are not indicat e (- ) data. Indicate 0 to XX kt .
(Note 2) XS = 2 and XS = 4 are use for LR525 built- in dimmer unit o~y.
(Note 3) X6 = 2 Grand is use for Wall mount only. (15b, 20c each 1 use)
Dimmer box (Flash mount type)
LD001 A-FD D D-D
(Connection diagram is for EL board)
66±0.2
MODEL L0001A-F
MASS 0 .5 kg
PANEL CUT
CONNECTION DIAGRAM
va, I 2ok2
I ·fil'A ,' I 6_:...Q 0 Uo V -· .
COAMING 20 MAGNETIC COMPASS SAFE DISTANCE LABEL
Dimmer box (Wall mount type)
LD001A-W0DD-D
(Connection diagram is for EL board)
M ODEL LD001A-W
MASS 0.5 kg
NAME PLATE
J- ~:,?- r/J 20 COAMING r/,20
MOUNTING DIMENSION
25±0.5
"' 0 ti g:J ~
2-M6 or r/J 7 HOLE
Yokogawa Denshikiki Co.,Ltd.
MAGNETIC COMPASS SAFE DISTANCE LABEL
CONNECTION DIAGRAM
Dimmer switch
LD002-ADD1
MODEL L D002
M A SS 0 . 1 kg
(Connection diagram is for LED illumination)
VARIABLE RESISTOR 20kQ 0.8w
12±0.3
M9 PO. 75
PANEL CUT
f ~ -;i
2 . KNOB
3. NAME PLATE
4.
NAME PLATE
1• 31.5 ·1~ I FOR SPEED ll«>fC ATOR I a:, I '""""'" I
CONNECTION DIAGRAM
2;;;;; I I 3
Dimmer box LD001A-X1 • • • X5/ 0ption
Type No. Suffix code Note
LDOOlA .................... For EML500/ 50
;<.1'·1'1~ Xl -F Flush mount
-w Wall mount
Rule / Name plate 1 None / J apanese & English
2 JG I Japanese & Engtish
3 JG I Japanese
5 None / English
6 MED / Japanese & English (Not e 3)
X2 7 MED / English (Note 3)
Color 1: Munsell 2.5G7 / 2
X3 Munsell 7.5BG7/2
Power supply 1 100V AC to 115V AC
2 200V AC to 220V AC
X4 3 For LED illumination
Name plate -1 HS1
-2 HD1
-3 HV1
-4 HV2
-5 FA1
X5 -6 FA2
Option I /CHS Name plate in Chinese
Dimmer switch LD002-X1 • • • X4 Type No. Suffix code Note
LDOOlA .................... For EML500/50
Style Xl -A Inner parts only
Power supply 1 200V
2 100V
X2 3 For LED illumination
Name plate 1: Japanese
X3 English
Usable equipment X4 I 1 LR524 / LR525