13 751.21042.TAP_Milliken Nature Center at Park Arch_CD Drawings - 09 Electrical.pdf

PDF 1 MB Posted

Attached to
751/21042. ABG; Milliken Nature Ctr @ Arch Rock - Restroom
Solicitation number
RFQ - 171 - 220000000529
Issued by
Mackinac County, Mackinac Island City, Michigan

About this file

This document is a set of technical specifications and drawings related to a state and local contract opportunity for the Milliken Nature Center at Arch Rock project in Mackinac County and Mackinac Island City, Michigan. The project involves electrical work including power distribution, lighting, and site utilities. Key details include electrical symbols, general notes, power and lighting plans, one-line diagrams, and a site plan. The work includes installing electrical panels, transformers, feeders, receptacles, switches, lighting fixtures, and other electrical equipment and systems. No specific bid due date or award date is provided, but the document includes COVID-19 precautions for attending meetings and submitting bids.

The electrical work is part of a larger construction project, with the State of Michigan serving as the owner. Pricing terms, set asides, and funding sources are not explicitly stated. However, the document provides detailed technical specifications and drawings to guide the electrical work on the project.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PC

NOTES:

RECEPTACLE SYMBOLS

M

S

ELD

S

BUSSMANN "SSU" W/FUSES

CIRCUIT BREAKER

MOUNT DEVICES AT HEIGHTS INDICATED UNLESS INDICATED

OTHERWISE ON PLANS. HEIGHTS ARE TO BOTTOM OF DEVICE.

DUPLEX RECEPTACLE - WITH GFI

DOUBLE DUPLEX RECEPTACLE

DUPLEX RECEPTACLE - FOR ELECTRIC WATER COOLER, WITH GFI

WP

GFI

HAND/HAIR DRYER

DUPLEX RECEPTACLE

HD

16"

DUPLEX RECEPTACLE - EMERGENCY

SPECIAL PURPOSE RECEPTACLE

MANUAL MOTOR STARTER WITH PILOT LIGHT 40"

SINGLE POLE SWITCH 40"

EXIT SIGN - CEILING MOUNTED

EXTERIOR POLE LIGHT

PHOTOCONTROL

EMERGENCY BATTERY UNIT

EWC

TRANSFORMER

CEILING FAN

CEILING FAN SPEED CONTROL 40"

OS

OS

OCCUPANCY SENSOR (SET TO VACANCY MODE) CEILING MOUNTED

OCCUPANCY SENSOR (SET TO VACANCY MODE) - WALL MOUNTED

EMERGENCY LIGHTING DEVICE - UL924 EMERGENCY SWITCHING DEVICE

(FORMERLY GTD)

DUPLEX RECEPTACLE - 4" ABOVE COUNTER BACKSPLASH

FLOOR DUPLEX RECEPTACLE

LEVITON #PFGF2-BZ

DISCONNECT SWITCH

M ELECTRIC METER

EXIT SIGN - WALL MOUNTED

16"

88"

88"

NETWORK LIGHTING CONTROL ZONE, REFER TO SCHEDULEZ

LOCAL, NON-SYSTEM 0-10V DIMMING CONTROLLER, SEE DETAILD

NETWORK LIGHTING SYSTEM - LOW VOLTAGE DIMMING/SWITCHING

CONTROLLER, SEE DETAIL

LV

A

A

ZONE #

(CIRCUIT)

40"

40"

NETWORK LIGHTING SYSTEM - TOUCH SCREEN SCENE CONTROLLER,

SEE DETAIL

SC A 40"

GFI GFCI REMOTE TRIP DEVICE, CONNECT NEARBY OUTLET TO LOAD SIDE 40"

DUPLEX RECEPTACLE - SURFACE MOUNTED #WM500

DUPLEX RECEPTACLE - HORIZONTAL MOUNTING

DUPLEX RECEPTACLE - WITH (2) USB OUTLETS BETWEEN POWERUSB

RECEPTACLES VARIATIONS - HEIGHT PER ABOVE UNLESS INDICATED ON DRAWINGS:

RECTANGULAR LIGHT FIXTURE

RECTANGULAR EMERGENCY LIGHT FIXTURE ON EMERGENCY

POWER, SWITCHABLE

DOWNLIGHT WALL WASH FIXTURE

WALL MTD. LIGHT FIXTURE

DOWNLIGHT FIXTURE

INDUSTRIAL LIGHT FIXTURE

DOWNLIGHT FIXTURE - EMERGENCY, SWITCHABLE

TRACK LIGHT - LENGTH AS INDICATED

FB POWER/COMMUNICATION FLOOR BOX

LEGRAND EVOLUTION #RFB4E-OG-6CTC2BZ, 1-1/4"C DATAA

EXTERIOR POLE LIGHT - POLE AND BASE PREPAIRED FOR CAMERA PER DETAIL.

LIGHTING SYMBOLS MOUNTING HEIGHTS POWER SYMBOLS MOUNTING HEIGHTS

NETWORK LIGHTING CONTROL SYMBOLS

DUPLEX RECEPTACLE - STACK ALIGNED BELOW DEVICE ABOVE

(DEVICE ALIGNMENT IS NOT LIMITED TO THOSE LABELED, REFER TO

ELECTRICAL DEVICE ALIGNMENT GUIDELINES)

H

ST

OSS

S 33S

SP

SD

3KS

S

SK

S3

SS

4KS

SWITCH AND PILOT LIGHT

DIMMER SWITCH (NON-SYSTEM TYPE) 0-10 ELV DIMMER

THREE-WAY SWITCH

FOUR-WAY SWITCH

KEY OPERATED, SINGLE POLE SWITCH

KEY OPERATED, THREE-WAY SWITCH

OCCUPANCY SENSOR (SET TO VACANCY MODE) - SWITCH MOUNTED

DUAL SINGLE POLE SWITCH

DUAL THREE-WAY SWITCH

KEY OPERATED, FOUR-WAY SWITCH

40"

40"

40"

40"

40"

40"

40"

40"

40"

40"

SLV-a LOW VOLTAGE CONTROL SWITCH, REFER TO DETAIL 40"

FS AUTOMATIC FLUSH SYSTEM

CS CHARGING STATION - LEVITON #PFUS1-BZ

JUNCTION BOXJB

DUPLEX RECEPTACLE - WET LOCATION WITH GFI

HUBBELL TAYMAC #ML500Z

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

E L E

C T

R

IC

A L

S Y

M B

O L

S A

N D

G E

N E

R A

L N

O T

E S

-1

.0

E

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

GENERAL LIGHTING NOTES

1 ALL OCCUPANCY SENSORS AND PHOTOCELLS MOUNTED IN THE

SAME ROOM SHALL BE CONNECTED TOGETHER AND OPERATE AS

ONE SYSTEM. MANUFACTURER SHALL PROVIDE FLOOR PLANS

DURING SHOP DRAWING PHASE SHOWING EXACT LOCATIONS AND

QUANTITIES AS REQUIRED FOR A COMPLETE SYSTEM.

2 ALL OCCUPANCY SENSOR WIRING SHALL BE CONCEALED WITHIN

CONDUIT WHERE EXPOSED. NO LOW VOLTAGE WIRING SHALL BE

EXPOSED.

3 ALL CONDUITS SHALL RUN AS TIGHT TO DECK AS POSSIBLE.

CONDUITS SHALL BE RUN IN A NEAT MANNER. MAINTAIN THE SAME

SPACING WHEN CONDUITS ARE RUN TOGETHER. CONCEAL JUNCTION

BOXES OVER LAY-IN CEILING AND USE EMT DROPS DOWN TO

CLOUDS. LOCATE CONDUIT DROPS TO CLOUDS AND CEILING

ELEMENTS IN LEAST VISIBLE LOCATION. NO MC-CABLE TO LIGHT

FIXTURES SHALL BE VISIBLE FROM ANY ANGLE.

4 RECESS NEW DEVICES AND ASSOCIATED CONDUIT AND BACKBOX IN

EXISTING WALL. CUT AND PATCH AS REQUIRED.

5 COORDINATE LIGHTING RUNS FOR LINEAR FIXTURES ALL TRADES. NO

PIPES, DUCTS, CONDUIT, CABLE TRAY OR ANY OTHER SYSTEMS

SHALL BE ROUTED UNDER LIGHTS.

6 ALL LIGHTING SWITCHES SHALL BE RECESSED IN THE PRECAST WALL

AND COORDINATED WITH THE PRECAST COMPANY, UNLESS

OTHERWISE NOTED IN THE DRAWINGS.

GENERAL POWER NOTES

1 ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CUTTING

AND PATCHING REQUIRED FOR NEW WORK OR WHERE DEVICES ARE

REMOVED AND NOT REPLACED.

2 ELECTRICAL CONTRACTOR SHALL COORDINATE WITH G SERIES SHEETS

DEVICE COORDINATION DETAIL. DEVICES ARE TO ALIGN VERTICALLY

AND HORIZONTALLY AND FOLLOW THE RULES OF THIS DETAIL

CONSISTENTLY. A PRE-INSTALL DEVICE COORDINATION MEETING FOR

DEVICE FINISHES AND LAYOUT MAY BE REQUIRED IN THE

SPECIFICATION FOR THIS PROJECT.

3 PATCH ALL PENETRATIONS AS REQUIRED TO MAINTAIN FIRE RATING.

4 REFER TO INTERIOR ELEVATIONS, SECTIONS, ARCHITECTURAL

ELEVATIONS AND RELATED DRAWINGS FOR EXACT DEVICE LOCATIONS

AND MOUNTING HEIGHTS. WHERE DEVICES ARE MOUNTED UNDER OR

ABOVE TACK BOARDS, DOORS, WINDOWS, OR ANY PIECE OF

EQUIPMENT, THE ELECTRICAL DEVICE SHALL BE CENTERED AS SHOWN.

COORDINATE LOCATION OF FURNITURE CONNECTIONS AND/OR

RECEPTACLES AND DATA RACEWAYS WITH APPROVED FURNITURE

SHOP DRAWINGS, FINAL CONNECTIONS TO FURNITURE BY ELECTRICAL

CONTRACTOR.

5 ALL CONDUITS SHALL RUN AS NEAR TO DECK AS PERMITTED BY CODE.

SOME CONDUITS WILL BE EXPOSED AND SHALL BE RUN IN A NEAT

MANNER. MAINTAIN THE SAME SPACING WHEN CONDUITS ARE RUN

TOGETHER. CONCEAL JUNCTION BOXES OVER LAY-IN CEILING AND

USE EMT DROPS DOWN TO CLOUDS. LOCATE CONDUIT DROPS TO

CLOUDS AND CEILING ELEMENTS IN LEAST VISIBLE LOCATION.

6 WHEN CEILINGS ARE REMOVED ELECTRICAL CONTRACTOR SHALL

PROPERLY SUPPORT ALL CONDUIT AND LOW VOLTAGE WIRING AS

REQUIRED PER NEC.

7 REMOVE CEILINGS AND GRID AS REQUIRED. REPLACE ANY DAMAGED

CEILINGS.

8 ALL LOW VOLTAGE CABLING SHALL BE RUN IN CONDUIT BETWEEN

DEVICE AND CABLE TRAY OR TECHNOLOGY RACK. NO CABLING SHALL

BE VISIBLE IN EXPOSED CEILING SPACES. EXPOSED CONDUIT SHALL

BE PAINTED TO MATCH SURFACE IT IS SUPPORTED FROM. WIRING

ROUTED IN ACCESSIBLE CEILING SPACES SHALL BE INDEPENDENTLY

SUPPORTED WITH COMM HOOKS OR RINGS.

9 CONNECT POWER TO ALL VAV, TERMINAL UNITS AND MISCELLANEOUS

MECHANICAL DAMPERS AND VALVES PROVIDED WITH LOW VOLTAGE

TRANSFORMERS. PROVIDE AT LEAST A CIRCUIT FOR EVERY 4 UNITS

TO BE ON A TRANSFORMER, COORDINATE EXACT LOCATIONS AND

TRANSFORMER QUANTITIES WITH BUILDING AUTOMATION SYSTEM AND

MECHANICAL CONTRACTORS AND REFER TO MECHANICAL CONTROLS

AND SEQUENCE OF OPERATIONS DETAIL. THESE ITEMS ARE NOT

SHOWN ON ELECTRICAL DRAWINGS. DO NOT USE SPARE BREAKERS

INDICATED IN PANEL SCHEDULES FOR THESE CIRCUITS, NOTIFY

PANELBOARD MANUFACTURERS OF QUANTITIES OF THESE BREAKERS

REQUIRED

10 CONNECT BAS CONTROL PANEL TO EMERGENCY CIRCUIT (IF

AVAILABLE) AND COORDINATE BAS PANEL LOCATION WITH CONTROLS

CONTRACTOR.

11 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.

PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT

AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED

ON EXTERIOR OF BUILDING.

12 PROVIDE 4" HOUSEKEEPING PADS FOR SWITCHGEAR, TRANSFORMERS

AND ALL FLOOR MOUNTED EQUIPMENT. PROVIDE FLEXIBLE

CONNECTION TO TRANSFORMERS AND SIMILAR EQUIPMENT PER

SPECIFICATIONS.

13 PROVIDE MINIMUM 2" CABLE ROUTE (UNLESS OTHERWISE NOTED ON

PLANS) FROM EACH TECHNOLOGY/DATA DROP INDICATED ON PLANS

TO NEAREST CABLE TRAY OR TECHNOLOGY CLOSET. AT ANY

DEMISING WALL, PROVIDE 2" SLEEVE ABOVE ACCESSIBLE CEILING

ABOVE LATCH SIDE OF EACH DOOR INTO ROOM. SLEEVES TO BE

MINIMUM 12" ON EACH SIDE OF WALL WITH BUSHINGS. FILL UNUSED

CONDUITS PRIOR TO COMPLETION OF CONSTRUCTION. EXTEND

SLEEVE AND GROUND TO NEAREST CABLE TRAY.

14 PROVIDE FINAL CONNECTION TO ALL OWNER/CONTRACTOR PROVIDED

EQUIPMENT. COORDINATE RECEPTACLE SIZES AND TYPE WITH

EQUIPMENT, ADJUST CIRCUIT SIZE AS REQUIRED.

15 FLOORBOX AND POKE THROUGH POWER AND RACEWAY TO FEED BACK

UP TO CEILING OF ROOM THAT FLOORBOX SERVES.

16 ALL RECEPTACLES AND ROUGH-INS SHALL BE RECESSED IN THE

PRECAST WALL AND COORDINATED WITH THE PRECAST COMPANY,

UNLESS OTHERWISE NOTED IN THE DRAWINGS.

17 LIGHTING SWITCHES, COVER PLATES, AND ELECTRICAL RECEPTACLES

SHALL BE BLACK UNLESS OTHERWISE NOTED IN THE DRAWINGS.

18 CONDUITS SHALL RUN STRAIGHT UP TO ABOVE CEILING. ELECTRICAL

CONTRACTOR SHALL BE ABLE TO INTERCEPT AND CONNECT THE

CONDUIT TO RUN BACK THE ELECTRICAL PANEL

GENERAL SITE NOTES

1 UNDERGROUND ROUTING OF CONDUIT IS DIAGRAMMATICAL AND FOR

BIDDING PURPOSES ONLY. FIELD VERIFY EXACT ROUTE AND BENDING

RADIUSES.

2 ALL CONDUITS SHALL ENTER/EXIT THE BUILDING BELOW GRADE.

PROVIDE TRENCHING AND DIRECTIONAL BORING AS REQUIRED. CUT

AND PATCH AS REQUIRED. NO EXPOSED CONDUIT SHALL BE ALLOWED

ON EXTERIOR OF BUILDING.

3 COORDINATE ALL SITE UTILITY WORK WITH ELECTRIC UTILITY.

4 THERE IS NO LOW VOLTAGE POWER AVAILABLE AT THE SITE. THE

CONTRACTOR SHALL PROVIDE IT FOR THE PROJECT WHERE

NECESSARY.

5 THE STATE WILL PROVIDE THE NECESSARY UTILITY TO SUPPORT THE

CONSTRUCTION OF THIS PROJECT. THE CONTRACTOR SHALL PROVIDE

ALL TEMPORARY SERVICE GEAR, METERING, DISCONNECTS, ETC.

NECESSARY FOR THEIR POWER USAGE. UTILITY COST FOR ELECTRIC

HEAT WILL NOT BE PROVIDED BY THE STATE.

ISSUED FOR DATE

T S

HD HD

HD HD

H

H

HD

H

H

EQ

H

EQ

H

H

H

H

H

FS

FS

FSM

H

H

H

H

H

H

H

H

H

H

H

H

M

C S

C S

CS CS CS CS CS

EQ

EQ

EQ

JB JB JB JB JB

JB JB JB JB JB

M

AV

RL-1-26, 16", GFCI

RL-1-19, 16", GFCI

RL-1-18, 40", GFCI

PROVISION FOR

FUTURE PROJECTOR -

CEILING INSTALLATION

RL-1-34, 16", GFCI

RL-1

RL-1-18

, FAUCET, 16"

RL-1-19

, FAUCET, 16"

RL-1-26

, FAUCET, 16"

RL-1-21

, VENDING, WP, 16", GFCI

WH-1, RL-1-5,7

RL-1-15 RL-1-17

MECH. PANEL, RL-1-9

COORDINATE FINAL LOCATION

WITH MECHANICAL DISCIPLINE

TX-PRI

RL-1-20

RL-1-22 RL-1-24

RL-2-4, 16"

E 201

RL-1-19, 16", GFCI

RL-1-26, 16", GFCI

RL-1-28

RL-1-25

RL-1-18

M

CP-1, RL-1-23

RL-2

RL-2-11, 16"

RL-2-11, 16"

RL-2-6, 16"

RL-2-6, 16"

RL-2-4, 16"

RL-2-7, 16"

RL-2-7, 16"

RL-2-2, 16"

RL-2-2, 16"

RL-2-5, 16"

RL-2-5, 16"

RL-2-13

, WP, 16", GFCI

RL-2-13

, WP, 16", GFCI

RL-2-10

, WP, 16", GFCI

RL-2-10

, WP, 16", GFCI

WOMEN

SUPPORT

FAMILY TOILET

MEN

NATURE CENTER

DECK

STORAGE

BREEZEWAY

SEATING

RL-2-9

RL-2-9

RL-2-8RL-2-8

RL-2-11

EF-1, RL-2-15

E 101

E 101

TR-1, RL-2-17,19

TR-1, RL-2-17,19

TR-1, RL-2-17,19

RL-1-31

RL-1-31

RL-2-16 RL-2-16 RL-2-21 RL-2-21 RL-2-21

3 3 3 3 3

3 3 3 3 3

HP-1, RL-1-11,13

HP-2, RL-1-14,16

RL-1-34, WP

RL-1-33

RL-1-33

RL-1-33

ERV-1, RL-1-6,8

AHU-1, RL-1-10,12

AHU-2, RL-2-12,14

GT-1, RL-1-36

GP-1, RL-1-35,37

5 5

RL-2-6

CHARGING STATIONS SHALL BE

INSTALLED RECESSED ON THE

FACE OF THE BENCH

CHARGING STATION

CONDUIT EMBEDDED IN THE PRECAST WALL

COORDINATION WITH PRECAST COMPANY REQUIRED

CONDUIT ABOVE CEILING FOR

ELECTRICAL INTERCEPTION

AND CONNECTION

ARMORED CABLE OR

FLEXIBLE CONDUIT

CHARGING STATIONS SHALL BE

INSTALLED RECESSED ON THE

FACE OF THE BENCH

CONDUIT RUNS EMBEDDED IN THE PRECAST

COORDINATION WITH PRECAST COMPANY REQUIRED

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R P

O W

E R

P L A

N

-1

.0

E

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

ELECTRICAL KEYED NOTES

1/4" = 1'-0"

FIRST FLOOR POWER PLAN

MILLIKEN PARK ARCH ROCK

UNIT A

UNIT B

KEY PLAN

SCALE: NO SCALE

SCALE: NONEE 101

2 CHARGING STATION INSTALLATION - BENCH 1 FRONT VIEW

SCALE: NONEE 101

3 CHARGING STATION INSTALLATION - BENCH SIDE VIEW

SCALE: NONEE 101

4 CHARGING STATION INSTALLATION - BENCH 2 FRONT VIEW

1 FINAL LOCATION FOR THE ELECTRICAL METER SHALL BE COORDINATED

WITH THE UTILITY COMPANY AND THE STATE PARK.

2 FLOOR BOX SHALL BE INSTALLED FLUSHED WITH THE FINISHED FLOOR

TO AVOID TRIPPING HAZARD.

3 COORDINATE EXACT LOCATION WITH FLUSH VALVE. PROVIDE ALL LINE

VOLTAGE AND LOW VOLTAGE WIRING. WIRE TO A REMOTE

TRANSFORMER IN THE SUPPORT 103.

4 CONNECT TO THE LOAD SIDE OF THE UPSTREAM RECEPTACLE.

5 CONDUITS SHALL RUN TO THE CLOSEST COLUMN AND THEN STRAIGHT

UP TO ABOVE CEILING. ELECTRICAL CONTRACTOR SHALL BE ABLE TO

INTERCEPT AND CONNECT THE CONDUIT TO RUN BACK THE ELECTRICAL

PANEL

T S

HD HD

HD HD

H

H

HD

H

H

EQ

H

EQ

H

H

H

H

H

FS

FS

FSM

H

H

H

H

H

H

H

H

H

H

H

H

M

C S

C S

CS CS CS CS CS

EQ

EQ

EQ

JB JB JB JB JB

JB JB JB JB JB

M

AV

RL-1

TX-PRI

M

RL-2

UNDERGROUND FEEDER TO

SOLAR INVERTER - 1IN

(2) FEEDERS #3AWG

(1) GROUNDING #8AWG

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R P

O W

E R

P L

A N

A

L T

E R

N A

T E

-1

.0

E

.A

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

MILLIKEN PARK ARCH ROCK

UNIT A

UNIT B

KEY PLAN

SCALE: NO SCALE

ELECTRICAL ALTERNATE KEYED NOTES

1 PROPOSED LOCATION FOR FUTURE PHOTOVOLTAIC SOLAR SYSTEM

PANEL

2 FINAL LOCATION FOR THE FUSED DISCONNECT SWITCH SHALL BE

COORDINATED WITH THE UTILITY COMPANY. FUSED DISCONNECT

SHALL BE SIZED TO SERVICE RATE.

1/4" = 1'-0"

FIRST FLOOR POWER PLAN - ALTERNATE 2

FUTURE PV

SOLAR PANELS

LOCATION

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

R O

O F

P L A

N

-1

.0

E

.A

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

1/4" = 1'-0"

ROOF PLAN - FUTURE SOLAR PANELS LOCATION

MILLIKEN PARK ARCH ROCK

UNIT A

UNIT B

KEY PLAN

SCALE: NO SCALE

K

K

L V

L V

D

K

L V

PC

L V

L V

L V

L V

OSOS

OSOS

OS

L V

OS

OS

P1-EM P1-EM P1

80" AFF X1

RL-1-32

X1

RL-1-32

P1-EM

96" AFF

P1

W10 W10 1 1

W5

WOMEN

STORAGE

DECK

SUPPORT

103 FAMILY TOILET

MEN

NATURE CENTER

W10 W10 W51 1 1

E 201

S2 S2S2 S2S2 S2

S1 S1 S1

S1

S2 S2S2 S2S2 S2

S1 S1 S1 S1 S1

H1 H1 H1

H1H1H1

H1 H1

H1

H1

H2

H2

H2

H2 H2

H2

H2

H2 H2

H2

H2

H2

H2

H2

H2

H2H2

H2

H2

H2H2

H2

H2

H2

H2

H2

H2

H2

H2

H2

H2

H2 H2

H2

H2

H2 H2

H2

H2

H2

H3-EM H3

H3H3-EM

H3

H3H3-EM

H3-EM

H3

H3

H3 H3-EM

H3-EM H3

H3

C1

C1

C1

C1

C1

C1

C1 C1

C1

DECORATIVE SCONCES SHALL BE

INSTALLED ALL THE WAY AGAINST

THE CEILING OR BEAM.

D1-EM D1 D1-EM D1

D1 D1-EM D1

D1 D1 D1

D1-EM

D1

D1D1-EMD1

D1-EM

D1-EM

D1 D1

D1 D1-EM D1

D1

D1

D1-EM D1

D1-EM D1

D1-EM D1

D1-EM

S3 S3 S3 S3 S3

C1

E 201

R10-EM

RL-1- 30

RL-1- 30

RL-1- 27

RL-1- 27

RL-1- 30

RL-1- 30

RL-1- 30

RL-1- 30

RL-1- 30

H2

RL-1-32

RL-1- 32

RL-1- 32

RL-1- 29

RL-1- 29

RL-1- 29

RL-1- 29

R10-EMR10

RL-1- 27

R5

R5

R10-EMR10R10-EM

RL-1- 27

80" AFF80" AFF80" AFF

RL-1

RL-2

RL-1- 32

R8-EM

RL-1- 27

BREEZEWAY

SEATING

C1C1

4 4

THREADED ROD

WALL

CEDAR PLANK

CEILING

LIGHTING FIXTURE W TYPE

SCREW

FLANGE

LIGHT SHALL BE

ADJUSTED TO

PROVIDE THIS AREA

OF COVERAGE

LIGHT SHALL BE ADJUSTED

TO PROVIDE THIS AREA OF

COVERAGE

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

F

IR

S T

F L

O O

R L

IG

H

T

IN

G P

L A

N

-1

.0

E

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

LIGHTING KEYED NOTES

1 PERIMETER LIGHTS ARE EQUIPPED WITH TELESCOPE ARMS ON BOTH

ENDS THAT SHALL BE EXTENDED OPEN TO COVER THE CEILING

OPENING BETWEEN BEAMS.

2 PROVIDE PHOTOCELL ON BUILDING AND COORDINATE TIME

SCHEDULE WITH OWNER. OUTDOOR LIGHTING SHALL TURN ON TO

FULL BRIGHTNESS AT DUSK, DIM AT USER PROGRAMMED TIME, AND

TURN OFF AT DAWN. PROVIDE LIGHTING CONTROL SYSTEM TO HAVE

FUTURE CAPACITY OF MINIMUM 3 ZONES FOR FUTURE SITE

LIGHTING.

3 LIGHTING SWITCHES SHALL CONTROL THE OUTDOOR LIGHTING AND

OFFER DIMMABLE FEATURE. ONE SWITCH SHALL BE DEDICATED TO

THE SIGNAGE LIGHTS (S3), ANOTHER ONE DEDICIATED TO THE

FIXTURES MOUNTED ON THE COLUMNS (C1), A THIRD ONE

DEDICATED TO THE OUTDOOR AMBIENT LIGHTING (D1), AND A

FOURTH TO FIXTURE TYPE (S1).

4 OCCUPANCY SENSOR SHALL BE NLIGHT MODEL NRM-PDT-10-ADCX -

BLACK COLOR

5 LIGHTING CONTROL TO FUNCTION AS REQUIRED BY ASHRAE

90.1.2013. FOR RESTROOM SPACES, THE CONTROLS REQUIRED ARE

DESCRIBED BELOW:

LOCAL CONTROL: MANUAL ON/OFF. THE DEVICE INSTALLED TO COMPLY

WITH THIS PROVISION SHALL BE READILY ACCESSIBLE AND LOCATED

SO THAT THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING WHEN

USING THE CONTROL DEVICE.

AUTOMATIC FULL OFF: ALL LIGHTING SHALL BE AUTOMATICALLY SHUT

OFF WITHIN 20 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE.

6 LIGHTING CONTROL TO FUNCTION AS REQUIRED BY ASHRAE

90.1.2013. FOR MULTIPURPOSE SPACES, THE CONTROLS REQUIRED

ARE DESCRIBED BELOW:

LOCAL CONTROL: THE DEVICE INSTALLED TO COMPLY WITH THIS

PROVISION SHALL BE READILY ACCESSIBLE AND LOCATED SO THAT

THE OCCUPANTS CAN SEE THE CONTROLLED LIGHTING WHEN USING

THE CONTROL DEVICE.

RESTRICTED TO PARTIAL AUTOMATIC ON: NO MORE THAN 50% OF

THE LIGHTING POWER FOR THE GENERAL LIGHTING SHALL BE ALLOWED

TO BE AUTOMATICALLY TURNED ON, AND NONE OF THE REMAINING

LIGHTING SHALL BE AUTOMATICALLY TURNED ON.

AUTOMATIC FULL OFF: ALL LIGHTING SHALL BE AUTOMATICALLY SHUT

OFF WITHIN 20 MINUTES OF ALL OCCUPANTS LEAVING THE SPACE.

1/4" = 1'-0"

FIRST FLOOR LIGHTING PLAN

1 1/2" = 1'-0"E 201

2 PERIMETER LIGHTING - RESTROOM DETAIL - W TYPE

LIGHT FIXTURE SCHEDULE - CUSTOM MITERED ASSEMBLIES

TYPE DESCRIPTION MANUFACTURER MOUNTING WATTS NOTES

C1 DECORATIVE ALVA #BRIAN-15.5"-3000K-MT1-DBT WALL MOUNT 18 VA 1, 2, 8

D1 RECESSED DOWNLIGHT GOTHAM #EVO4SH-35/15-DFRBR-SOL-MVOLT-EZ10 RECESSED 14 VA 1, 2, 4, 7

H1 ARCHITECTURAL TRACK JUNO TRAC-MASTER: #TREC 8FT - BLACK SURFACE 1, 2

H2 LED TRACK HEAD JUNO: #R620L-27K-90CRI-PDIM-VBS-BL TRACK 15 VA 1, 2

H3 ARCHITECTURAL PENDANT METEOR #OR4-25-358-UNV-STV-60-BLK-BLK-CM10-RM PENDANT 25 VA 1, 2, 4, 7

P1 INDUSTRIAL PENDANT LITHONIA #CLX LED-L48-4000LM-SEF-SBLMB-WDL-WD-MVOLT-GZ10-40K-80CRI-E10WLCP-MB-ZAC120 PENDANT 28 VA 1,2 ,3, 4

R5 LINEAR RECESSED FINELITE #HP-X-R-D-5'8"-S-835-F-120-SC-FC-10%-SF-FE-FB RECESSED 20 VA 1, 2, 4, 7

R8 LINEAR RECESSED FINELITE #HP-X-R-D-8'-S-835-F-120-SC-FC-10%-SF-FE-FB RECESSED 29 VA 1, 2, 4, 7

R10 LINEAR RECESSED FINELITE #HP-X-R-D-10'8"-S-835-F-120-SC-FC-10%-SF-FE-FB RECESSED 38 VA 1, 2, 4, 7

S1 WALL WASH ACULUX #LN1SQ-D-04C-30K-80CRI-R35D-UGZ-MVOLT-NLIGHT-BS-BLSF RECESSED 10 VA 1, 2, 8

S2 WALL WASH ACULUX #LN1SQ-A-04C-30K-80CRI-R35D-UGZ-MVOLT-NLIGHT-BS-BLSF RECESSED 10 VA 1, 2, 8

S3 SIGNAGE ACULUX #LN1SQ-A-12C-30K-80CRI-R50D-UGZ-MVOLT-NLIGHT-BS-BLSF RECESSED 24 VA 1,2, 8

W5 PERIMETER LIGHTING FINELITE #HP-WS-6W-4D-5'-S-835-SW-120-SC-FC-10%-TR-SF-TXL-L-TXL-R-SW THREADED ROD 18 VA 1, 2, 3

W10 PERIMETER LIGHTING FINELITE #HP-WS-6W-4D-10'-S-835-SW-120-SC-FC-10%-TR-SF-TXL-L-TXL-R-SW THREADED ROD 36 VA 1, 2, 3

X1 EXIT SIGN - EDGE LIT LITHONIA : #EDGR 1 G EL SD RECESSED 2 VA 1, 2, 5

* FIELD COORDINATE AND FIELD MEASURE FOR CUSTOM LENGTH FIXTURES, LENGTHS PROVIDED ARE ROUNDED AND DEPEND ON FIELD CONDITIONS.

1 ALL LED FIXTURES TO HAVE WARRANTY TO MEET OR EXCEED WARRANTY INCLUDED IN BASIS OF DESIGN. FIXTURES LISTED AS EQUALS SHALL MEET DELIVERED LUMENS, CRI, EFFICACY

AND OPTIONS OF THAT SPECIFIED. REFER TO SPECIFICATIONS 265100 AND 265600 FOR ADDITIONAL REQUIREMENTS.

2 THE MOUNTING DESCRIPTION IS GENERAL. REFER TO SHOP DRAWINGS AND MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR SPECIFIC MOUNTING DETAILS.

3 FIXTURE LENGTH PER DRAWINGS.

4 FIXTURES WITH THE CENTER CIRCLE SHADED AND/OR WITH "-EM" WITH FIXTURE TYPE LABEL SHALL HAVE A SELF-CONTAINED EMERGENCY BATTERY PACK OPERATING TWO LAMPS AT A

MINIMUM OF 1100 LUMENS FOR 90 MINUTES. FIXTURES WITH THE CENTER CIRCLE COMPLETELY SHADED SHALL BE ON 24 HOURS. ON HID FIXTURES PROVIDE TIME DELAY RELAY AND

STAND-BY QUARTZ RESTRIKE LAMP. WIRE BATTERY AND BALLAST SO FIXTURE TURNS "ON" WHEN POWER FAILS.

5 EXIT SIGNS DIRECTIONAL ARROWS TO BE CONFIRMED ON PLANS PRIOR TO ORDERING. ARROWS ON GRAPHICS MAY NOT MATCH THOSE OF DESCRIPTION DUE TO FACE DIRECTION IN

REFERENCE.

6 ONLY SUBMIT ONE SET OF LINEAR FIXTURE INFORMATION PER FIXTURE SERIES WHERE VARIOUS LENGTH FIXTURES OF SAME SERIES ARE USED.

7 PROVIDE EMERGENCY BATTERY PACK FOR SELECTIVE FIXTURES.

8 LIGHT FIXTURE TO BE CONTROLLED BY THE PHOTOCELL MOUNTED ON THE EXTERIOR OF THE BUILDING VIA LIGHTING CONTROL SYSTEM.

SCALE: NONEE 201

3 OUTDOOR LIGHTING DETAIL - S2 TYPE

SCALE: NONEE 201

4 SIGNAGE LIGHTING DETAIL

MILLIKEN PARK ARCH ROCK

UNIT A

UNIT B

KEY PLAN

SCALE: NO SCALE

400A/2P

A /2

P

RL-1

240/120V 1Ø, 3W

DEMAND: 227A

SPD

240/120V

TX-PRI

EXISTING METER. CONTRACTOR TO COORDINATE

FINAL METER LOCATION WITH UTILITY COMPANY.

M

UTILITY COMPANY SCOPE

SQUARE-D - NQ

SUPPORT 103

A /2

P

RL-2

PANEL

SPD

SQUARE-D - NQ

STORAGE 107

GROUND BUS

10' SPACING (TYP)

WATER MAIN

#3/0 Cu GND (TYP)

10'-0"

GROUND ROD

100%

CONNECTION BY UTILITY COMPANY

FEEDERS #600AWG

GROUNDING #3AWG

FEEDERS #600AWG

GROUNDING #3AWG

EXISTING

240/120V 1Ø, 3W DEMAND: not in model

240/120V

TX-PRI

M

UTILITY COMPANY SCOPE

EXISTING METER SHALL BE

DEMOLISHED AND RELOCATED. FINAL

LOCATION AND INSTALLATION DETAILS

SHALL BE COORDIANTED WITH UTILITY

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

E L E

C T

R

IC

A L

O N

E L

IN

E

-1

.0

E

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

GENERAL

CONDUIT SIZES BASED ON EMT AND COPPER CONDUCTORS UNLESS OTHERWISE NOTED. UPSIZE AS REQUIRED WHERE PVC OR GALVANIZED IS USED OR REQUIRED PER SPECIFICATIONS.

1 PROVIDE DRY CONTACT FROM GENERATOR ATS TO ELEVATOR CONTROLLER TO INDICATE GENERATOR RUNNING ON EMERGENCY POWER.

2 PROVIDE RAINTIGHT DISCONNECT AT EQUIPMENT ON ROOF AND REMOTE STARTER IN ELECTRICAL ROOM.

3 PROVIDE CONNECTION TO ROOFTOP EQUIPMENT AND INTERCONNECT BETWEEN OUTSIDE UNIT AND INTERIOR UNIT. REFER TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. PROVIDE RAINTIGHT DISCONNECT ON EXTERIOR

UNIT.

4 PROVIDE COPPER CONDUCTORS ONLY FOR CHILLER, ALUMINUM CONDUCTORS ARE NOT ACCEPTABLE FOR USE WITH CHILLER CONNECTIONS. DO NOT INCLUDE CHILLER FEEDS IN ANY ALUMINUM FEEDER ALTERNATES

(VOLUNTARY OR ON DRAWINGS).

GENERAL: CONDUIT SIZES BASED ON EMT. UPSIZE AS REQUIRED WHERE PVC OR GALVANIZED IS USED OR REQUIRED PER SPECIFICATIONS.

1 CONDUIT SIZES BASED ON EMT AND COPPER CONDUCTORS (UNLESS OTHERWISE INDICATED WITH AN "AL" FOR ALUMINUM). UPSIZE AS REQUIRED WHERE PVC OR GALVANIZED IS USED

OR REQUIRED PER SPECIFICATIONS.

2 G.E.C. = GROUNDING ELECTRODE CONDUCTOR FOR SEPARATELY DERIVED SYSTEM (PER SET, USE EQUIVALENT CMIL AND GEC FROM 250.66)

3 GND. = EQUIPMENT GROUNDING CONDUCTOR (E.G.C.)

ELECTRICAL PANEL FEEDER SCHEDULE

DESCRIPTION FED FROM

CURRENT

(FLA)

DEMAND

(FLA)

FEEDER

ACCUM VOLT

DROP % NOTESBREAKER / POLES

# OF

SETS WIRE GROUND EMT

240 V

RL-1 TX-PRI 228 A 400 A / 2 1 SET 3 #600 KCMIL #3 GND. 3 1/2" 0.0%

RL-2 RL-1 60 A 100 A / 2 1 SET 3 #3 #8 GND. 1 1/4" 0.0%

ELECTRICAL HVAC FEEDER SCHEDULE

DESCRIPTION FED FROM DISCONNECT MEANS

CURRENT

(FLA)

DEMAND

(FLA)

FEEDER

ACCUM VOLT

DROP % NOTESBREAKER / POLES

# OF

SETS WIRE GROUND EMT

240 V

HVAC - AHU-1 - SUPPORT 103 RL-1 DISCONNECT BY DIV. 23 20 A 20 A 35 A / 2 1 SET 3 #8 #10 GND. 3/4" 0.0%

HVAC - AHU-2 - NATURE CENTER 101 RL-2 DISCONNECT BY DIV. 23 20 A 20 A 35 A / 2 1 SET 3 #8 #10 GND. 3/4" 0.0%

HVAC - ERV-1 - SUPPORT 103 RL-1 DISCONNECT BY DIV. 23 13 A 13 A 20 A / 2 1 SET 3 #12 #12 GND. 3/4" 0.0%

HVAC - GP-1 GREYWATER - SUPPORT 103 RL-1 DISCONNECT BY DIV. 23 13 A 13 A 20 A / 2 1 SET 3 #12 #12 GND. 3/4" 0.0%

HVAC - HEAT PUMP HP-1 - OUTDOOR RL-1 DISCONNECT BY DIV. 23 20 A 20 A 35 A / 2 1 SET 3 #8 #10 GND. 3/4" 0.0%

HVAC - HEAT PUMP HP-2 - OUTDOOR RL-1 DISCONNECT BY DIV. 23 20 A 20 A 35 A / 2 1 SET 3 #8 #10 GND. 3/4" 0.0%

HVAC - HEATED TERMINALS - NATURE CENTER 101 RL-2 NON-FUSED DISCONNECT 30A 13 A 13 A 20 A / 2 1 SET 3 #10 #10 GND. 3/4" 0.0%

HVAC - WATER HEATER WH-1 - SUPPORT 103 RL-1 30A DISCONNECT, LOCKABLE 19 A 19 A 30 A / 2 1 SET 3 #10 #10 GND. 3/4" 0.0%

120 V

HVAC - CP-1 - SUPPORT 103 RL-1 MANUAL MOTOR STARTER 1 A 1 A 20 A / 1 1 SET 3 #12 #12 GND. 3/4" 0.0%

HVAC - EF-1 - STORAGE 107 RL-2 MANUAL MOTOR STARTER 13 A 13 A 20 A / 1 1 SET 3 #12 #12 GND. 3/4" 0.0%

HVAC - GT-1 GREYWATER SUMP TANK RL-1 MANUAL MOTOR STARTER, NEMA 3R 5 A 5 A 20 A / 1 1 SET 3 #12 #12 GND. 3/4" 0.0%

HVAC - MECH. PANEL - SUPPORT 103 RL-1 -- 13 A 13 A 20 A / 1 1 SET 3 #12 #12 GND. 3/4" 0.0%

SCALE: NONE

NEW CONSTRUCTION ONE-LINE DIAGRAM

SCALE: NONE

DEMOILITION ONE-LINE DIAGRAM

PROVIDE SPD BREAKER PER ONELINE SCHEDULE.

IC RATING IS CALCULATED VALUE, PROVIDE IC RATING AT LEAST 25% HIGHER AS PER SPECIFICATIONS.

NOTES: PROVIDE 100A/2P BREAKER FOR FUTURE INVETER SOLAR PANEL

HAND DRYER - 4500 VA 100.00% 4500 VA

Lighting 330 VA 100.00% 330 VA

RECEPTACLE - 6480 VA 100.00% 6480 VA TOTAL ESTIMATED DEMAND... 228 A

POWER - 4900 VA 100.00% 4900 VA TOTAL CONNECTED LOAD (A): 228 A

Other 180 VA 100.00% 180 VA TOTAL ESTIMATED DEMAND: 54613 VA

LIGHTING - 1600 VA 100.00% 1600 VA TOTAL CONNECTED LOAD: 54613 VA

HVAC - 36770 VA 100.00% 36770 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

TOTAL AMPS: 229 A 226 A

ADDITIONAL FEED THRU LUGS LOAD (IF APPLICABLE): 0 VA 0 VA

TOTAL LOAD: 27530 VA 27086 VA

59 SPARE 20 1 0 0 -- -- -- 60

57 SPARE 20 1 0 0 2 100 FUTURE INVERTER - SOLAR PANEL 58

55 SPARE 20 1 0 0 -- -- -- 56

53 SPARE 20 1 0 0 2 30 SPARE 54

51 SPARE 20 1 0 0 1 20 SPARE 52

49 SPARE 20 1 0 0 1 20 SPARE 50

47 SPARE 20 1 0 0 1 20 SPARE 48

45 SPARE 20 1 0 0 1 20 SPARE 46

43 SPARE 20 1 0 0 1 20 SPARE 44

41 SPARE 20 1 0 0 1 20 SPARE 42

39 SPARE 20 1 0 0 1 20 SPARE 40

37 -- -- -- 1500 0 1 20 SPARE 38

35 HVAC - GP-1 GREYWATER - SUPPORT 103 20 2 1500 600 1 20 HVAC - GT-1 GREYWATER SUMP TANK 36

33 RECEPTACLE - SUPPORT 103 20 1 540 360 1 20 RECEPTACLE - SUPPORT 103 34

31 POWER - CHARGING STATIONS - BREEZEWAY 106 20 1 600 735 1 20 LIGHTING - TRACK AND AMBIENT - NATURE... 32

29 LIGHTING - BREEZEWAY, ENTRANCE 20 1 425 539 1 20 LIGHTING - OUTDOOR LIGHTING 30

27 LIGHTING - RESTROOMS, SUPPORT 20 1 592 1500 1 20 POWER - TRANSF. FLUSH SYSTEM - WOMEN 104 28

25 POWER - TRANSF. FLUSH SYSTEM - MEN 102 20 1 1500 540 1 20 RECEPTACLE - MEN 102 26

23 HVAC - CP-1 - SUPPORT 103 20 1 70 900 1 20 POWER - HAND DRYER - MEN 102 24

21 RECEPTACLE - VENDING AND HYDRATION 20 1 180 900 1 20 POWER - HAND DRYER - MEN 102 22

19 RECEPTACLE - WOMEN 104 20 1 540 900 1 20 POWER - HAND DRYER - FAMILY TOILET 105 20

17 POWER - HAND DRYER - WOMEN 104 20 1 900 660 1 20 RECEP. AND FLUSH SYSTEM - FAMILY TOILET 105 18

15 POWER - HAND DRYER - WOMEN 104 20 1 900 2450 -- -- -- 16

13 -- -- -- 2450 2450 2 35 HVAC - HEAT PUMP HP-2 - OUTDOOR 14

11 HVAC - HEAT PUMP HP-1 - OUTDOOR 35 2 2450 2450 -- -- -- 12

9 HVAC - MECH. PANEL - SUPPORT 103 20 1 1500 2450 2 35 HVAC - AHU-1 - SUPPORT 103 10

7 -- -- -- 2250 1500 -- -- -- 8

5 HVAC - WATER HEATER WH-1 - SUPPORT 103 30 2 2250 1500 2 20 HVAC - ERV-1 - SUPPORT 103 6

3 -- -- -- 0 7470 -- -- -- 4

1 SPD 30 2 0 6890 2 100 RL-2 2

CIRCUIT DESCRIPTION TRIP (A) POLES A B POLES TRIP (A) CIRCUIT DESCRIPTION

(PROVIDE AT LEAST 25% HIGHER I.C.)

ADDED ACCESSORIES: SPD FEED-THRU LUGS... I.C. RATING:

LOCATION: SUPPORT 103 / FIRST FLOOR AMPS: 400 A MB FED FROM: TX-PRI

PANEL: RL-1 MOUNTING: SURFACE VOLTAGE: 120/240V, 1PH, 3W

PANELBOARD " RL-1" LOAD SCHEDULE

PROVIDE SPD BREAKER PER ONELINE SCHEDULE.

IC RATING IS CALCULATED VALUE, PROVIDE IC RATING AT LEAST 25% HIGHER AS PER SPECIFICATIONS.

NOTES:

TOTAL ESTIMATED DEMAND... 60 A

TOTAL CONNECTED LOAD (A): 60 A

RECEPTACLE - 3960 VA 100.00% 3960 VA TOTAL ESTIMATED DEMAND: 14360 VA

POWER - 1000 VA 100.00% 1000 VA TOTAL CONNECTED LOAD: 14360 VA

HVAC - 9400 VA 100.00% 9400 VA

LOAD CLASSIFICATION CONNECTED LOAD DEMAND FACTOR ESTIMATED DEMAND PANEL TOTALS

TOTAL AMPS: 57 A 62 A

ADDITIONAL FEED THRU LUGS LOAD (IF APPLICABLE): 0 VA 0 VA

TOTAL LOAD: 6890 VA 7470 VA

41 SPARE 20 1 0 0 1 20 SPARE 42

39 SPARE 20 1 0 0 1 20 SPARE 40

37 SPARE 20 1 0 0 1 20 SPARE 38

35 SPARE 20 1 0 0 1 20 SPARE 36

33 SPARE 20 1 0 0 1 20 SPARE 34

31 SPARE 20 1 0 0 1 20 SPARE 32

29 SPARE 20 1 0 0 1 20 SPARE 30

27 SPARE 20 1 0 0 1 20 SPARE 28

25 SPARE 20 1 0 0 1 20 SPARE 26

23 SPARE 20 1 0 0 1 20 SPARE 24

21 POWER - CHARGING STATIONS - SEATING 109 20 1 600 0 1 20 SPARE 22

19 -- -- -- 1500 0 -- -- -- 20

17 HVAC - HEATED TERMINALS - NATURE CENTER 101 20 2 1500 0 2 30 SPARE 18

15 HVAC - EF-1 - STORAGE 107 20 1 1500 400 1 20 POWER - CHARGING STATIONS - SEATING 109 16

13 RECEPTACLE - DECK 108 - OUTDOOR RATED 20 1 360 2450 -- -- -- 14

11 RECEPTACLE - NATURE CENTER 101 20 1 540 2450 2 35 HVAC - AHU-2 - NATURE CENTER 101 12

9 RECEPTACLE - NATURE CENTER 101 20 1 360 360 1 20 RECEPTACLE - DECK 108 - OUTDOOR RATED 10

7 RECEPTACLE - NATURE CENTER 101 20 1 360 360 1 20 RECEPTACLE - NATURE CENTER 101 8

5 RECEPTACLE - NATURE CENTER 101 20 1 360 540 1 20 RECEPTACLE - Room 107, 101 6

3 -- -- -- 0 360 1 20 RECEPTACLE - NATURE CENTER 101 4

1 SPD 30 2 0 360 1 20 RECEPTACLE - NATURE CENTER 101 2

CIRCUIT DESCRIPTION TRIP (A) POLES A B POLES TRIP (A) CIRCUIT DESCRIPTION

(PROVIDE AT LEAST 25% HIGHER I.C.)

ADDED ACCESSORIES: SPD FEED-THRU LUGS... I.C. RATING:

LOCATION: STORAGE 107 / FIRST FLOOR AMPS: 100 A MLO FED FROM: RL-1

PANEL: RL-2 MOUNTING: SURFACE VOLTAGE: 120/240V, 1PH, 3W

PANELBOARD " RL-2" LOAD SCHEDULE

30"

15" 15"

12"

24"

17"

UNDERGROUND FEEDER

4IN CONDUIT

(2) FEEDERS #600AWG

(1) GROUNDING #3AWG

EXISTING

TRANSFORMER

(TX-PRI)

UNDERGROUND FEEDER

TO RL-2 - 1IN

(2) FEEDERS #3AWG

(1) GROUNDING #8AWG

M

UTILITY METER. COORDINATE

FINAL LOCATION WITH

UTILITY COMPANY

UNDERGROUND FEEDER TO

RL-1 - 3-1/2IN CONDUIT

(2) FEEDERS #600AWG

(1) GROUNDING #3AWG

F

IL

E N

U M

B E

R

S T

A T

E I

N D

E X

N U

M B

E R

S

C o ns tr uc tio n

F in a l R e co rd

Is su e d f o r

P re lim in a ry

D a te

D E

S

IG

N A

N D

C O

N S

TR

U

C

TI

O N

D

IV

IS

IO

N

D E

P A

R T

M E

N T

O F

T E

C H

N O

L O

G Y

M

A N

A G

E M

E N

T

A N

D B

U D

G E

T S

T A

T E

O F

M

IC

H

IG

A N

A D

A M

P

L A

C H

R

A

D

IR

E C

T O

R

S T

A T

E F

A C

IL

IT

IE

S

A D

M

IN

IS

T

R A

T

IO

N

T O

W E

R P

IN

K

S T

E R

.C O

M

A L L R

IG

H

T S

R E

S E

R V

E D

S H

E E

T T

IT

L

E

S H

E E

T N

U M

B E

R

O W

N E

R P

R O

J E

C T

T

IT

L E

D A

T E

E L E

C T

R

IC

A L S

IT

E

P L A

N

-1

.0

E S

A U

G U

S T

M

IL

L

IK

E N

N A

T U

R E

C E

N T

E R

A T

A R

C H

R O

C K

M a c k in a c I s la n d

M ic h ig a n

S T

A T

E O

F M

IC

H

IG

A

N

/2

.T

A P

A U

G U

S T

3/32" = 1'-0"

ELECTRICAL SITE PLAN

Sheets
E 001 - ELECTRICAL SYMBOLS AND GENERAL NOTES
E 101 - FIRST FLOOR POWER PLAN
E 101.A2 - FIRST FLOOR POWER PLAN - ALTERNATE 2
E 150.A2 - ROOF PLAN
E 201 - FIRST FLOOR LIGHTING PLAN
E 401 - ELECTRICAL ONE LINE
ES 101 - ELECTRICAL SITE PLAN

File details come from the government source that posted it. Updated .