09 751.21042.TAP_Milliken Nature Center at Park Arch_CD Drawings - 05 Structural.pdf
PDF 3 MB Posted
- Solicitation number
- RFQ - 171 - 220000000529
- Issued by
- Mackinac County, Mackinac Island City, Michigan
About this file
This document contains details regarding a state and local contract opportunity for the Milliken Nature Center at Arch Rock project in Mackinac Island, Michigan. The project involves the construction of a new nature center building, including site work, foundations, structural steel framing, precast concrete wall panels, a metal roof, and mechanical/electrical/plumbing systems. The structural design details, load criteria, special inspection requirements, and construction notes are provided. The bid attachments must be uploaded to the SIGMA VSS system, and any questions should be emailed to the contact provided. COVID-19 precautions, such as mask requirements, may be in effect.
The contract opportunity is being issued by the State of Michigan Department of Technology, Management, and Budget. Pricing terms, set asides, and funding sources are not explicitly provided in the document. However, the project appears to be publicly funded, and the successful bidder will be required to comply with all applicable state and local requirements.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL DESIGN CRITERIA
1. GOVERNING CODE MICHIGAN BUILDING CODE (MBC), 2015 EDITION
2. BUILDING RISK CATEGORY II
3. DESIGN SOIL BEARING PRESSURE 2000 PSF
4. MATERIAL STRENGTHS
STRUCTURAL STEEL:
ASTM A992 (Fy = 50 KSI) - ROLLED STEEL SHAPES UNLESS NOTED ON THE
DRAWINGS.
ASTM A36 (Fy = 36 KSI) - ROLLED STEEL PLATES, CHANNELS, ANGLES, BARS, AND RODS AS NOTED ON THE DRAWINGS.
ASTM A500, GRADE C - RECTANGULAR AND ROUND HSS
REINFORCING STEEL:
ASTM A615, GRADE 60
CONCRETE:
4000 PSI FOR ALL CONCRETE UNLESS SPECIFICALLY NOTED OTHERWISE.
5. DEAD LOADS
ROOF
METAL ROOFING 3 PSF
INSULATION AND COVER BOARD 9 PSF
HANGING M/E/P ALLOWANCE 5 PSF
CEILING/MISCELLANEOUS 5 PSF
FRAMING 5 PSF
FUTURE PV ARRAY ALLOWANCE 12 PSF
TOTAL ROOF DEAD LOAD 39 PSF
6. DESIGN SNOW LOAD AND SNOW DRIFTING PARAMETERS ARE AS FOLLOWS:
GROUND SNOW LOAD (Pg) 60 PSF
FLAT ROOF SNOW LOAD (Pf) 46 PSF + DRIFT
SNOW EXPOSURE FACTOR (Ce) 0.9
SNOW THERMAL FACTOR (Ct) 1.2
SNOW LOAD IMPORTANCE FACTOR 1.0
7. WIND LOAD DESIGN PARAMETERS ARE AS FOLLOWS:
BASIC WIND SPEED (V), (3 SECOND GUST) 115 MPH
WIND EXPOSURE CATEGORY D
INTERNAL PRESSURE COEFFICIENT ±0.18
8. SEE TABLE FOR COMPONENTS AND CLADDING LOAD CRITERIA. ALL ARCHITECTURAL AND
STRUCTURAL COMPONENTS SHALL CONFORM WITH THE MICHIGAN BUILDING CODE AND
ASCE 7 FOR COMPONENTS AND CLADDING DESIGN.
ROOF PRESSURES (PSF)
WALL PRESSURES (PSF)
NOTES:
- END ZONE WIDTH IN FEET = 10% OF LEAST HORIZONTAL DIMENSION OR .4h
WHICHEVER IS SMALLER BUT NOT LESS THAN EITHER, 4% OF LEAST HORIZONTAL
DIMENSION OR 3'-0"
h=MEAN ROOF HEIGHT, IN FEET, EXCEPT THAT EAVE HEIGHT SHALL BE USED FOR
ROOF ANGLES < 10
9. SEISMIC LOAD DESIGN PARAMETERS ARE AS FOLLOWS:
SOIL SITE CLASS D
MAPPED SPECTRAL RESPONSE ACCELERATION
(Ss) 4.8 %
(S1) 2.5 %
DESIGN SPECTRAL RESPONSE ACCELERATION
(Sds) 5.3 %
(Sd1) 3.7 %
SEISMIC DESIGN CATEGORY A
SEISMIC IMPORTANCE FACTOR (Ie) 1.0
SEISMIC LATERAL FORCE RESISTING SYSTEM - ORDINARY PRECAST SHEAR WALLS
RESPONSE MODIFICATION FACTOR (R) 3
DEFLECTION AMPLIFICATION FACTOR (Cd) 3
SEISMIC DESIGN METHOD EQUIVALENT LATERAL FORCE PROCEDURE
SEISMIC RESPONSE COEFFICIENT (Cs) 0.0177
SEISMIC DESIGN STRUCTURE WEIGHT (W) 347 KIPS
SEISMIC DESIGN BASE SHEAR (V) 6.2 KIPS
GENERAL CONDITIONS
1. COORDINATE WITH ALL DRAWINGS FOR PERTINENT INFORMATION RELATED TO THE
STRUCTURAL WORK. ANY CHANGES TO THE STRUCTURAL SYSTEMS SHALL BE RE-DESIGNED
BY A REGISTERED PROFESSIONAL ENGINEER AT NO COST TO THE OWNER OR A/E AND
SUBMITTED TO THE A/E FOR REVIEW. SUBMITTAL SHALL BE ACKNOWLEDGED IN WRITING
BEFORE BEGINNING CONSTRUCTION
2. EQUIPMENT FRAMING LOADS, OPENINGS, AND STRUCTURE, IN ANY WAY RELATED TO HVAC,
PLUMBING, PROCESS, ELECTRICAL, ELEVATOR, OR ESCALATOR REQUIREMENTS ARE SHOWN
FOR BIDDING PURPOSES ONLY. CONTRACTOR SHALL OBTAIN APPROVAL OF THE PERTINENT
TRADES BEFORE PROCEEDING WITH SUCH PORTION OF THE WORK. EXCESS COST RELATED
TO VARIATION IN THESE REQUIREMENTS SHALL BE BORNE BY THE APPROPRIATE
CONTRACTOR.
3. IT IS SOLELY THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE ERECTION
PROCEDURE AND SEQUENCES TO ENSURE THE SAFETY OF THE BUILDING AND ITS
COMPONENTS DURING ERECTION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION
OF TEMPORARY BRACING, SHORING, GUYS, OR TIE-DOWNS THAT MAY BE NECESSARY.
4. THE STRUCTURE HAS BEEN DESIGNED FOR THE UNIFORM LOADS INDICATED IN ADDITION TO
THE CONCENTRATED LOADS REQUIRED BY THE BUILDING CODE. THE STRUCTURAL DESIGN
IS BASED SOLELY ON THE BUILDING IN ITS COMPLETED STATE. CONTRACTORS AND THEIR
SUB-CONTRACTORS SHALL TAKE NECESSARY PRECAUTIONS TO WITHSTAND ALL
HORIZONTAL AND VERTICAL LOADINGS THAT MAY BE ENCOUNTERED DURING
CONSTRUCTION PRIOR TO COMPLETION OF THE BUILDING. SUCH CONSTRUCTION
LOADINGS INCLUDE, BUT ARE NOT LIMITED TO, LOADS FROM CRANES, LIFTS, DOLLIES, AND
HOISTS. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE EVALUATION OF THE IMPACT
OF SUCH LOADS ON THE STRUCTURE AND PROVIDING TEMPORARY SHORING, BRACING, OR
REINFORCEMENT AS REQUIRED.
5. SEE THE ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS NOT SHOWN ON THE
STRUCTURAL DRAWINGS. ALL DIMENSIONS AND ELEVATIONS SHOWN ON THE STRUCTURAL
DRAWINGS SHALL BE VERIFIED BY THE CONTRACTOR AND SHALL CONFORM TO THOSE
SHOWN ON THE ARCHITECTURAL DRAWINGS. REPORT ALL DISCREPANCIES TO THE A/E FOR
RESOLUTION BEFORE PROCEEDING.
6. THE CONTRACTOR SHALL SUPPORT, BRACE, AND SECURE EXISTING STRUCTURES AS
REQUIRED. THE CONTRACTOR IS SOLELY RESPONSIBLE FOR THE SAFETY OF EXISTING
STRUCTURES DURING CONSTRUCTION. FIELD VERIFY ALL EXISTING DIMENSIONS WHICH
AFFECT THE NEW CONSTRUCTION PRIOR TO FINAL DETAILING AND FABRICATION OF NEW
STRUCTURAL ELEMENTS.
CAST-IN-PLACE CONCRETE
1. CAST-IN-PLACE CONCRETE WORK SHALL CONFORM TO THE PROJECT MANUAL AND
AMERICAN CONCRETE INSTITUTE CODES AND STANDARDS, INCLUDING, BUT NOT LIMITED
TO, ACI 301, ACI 315, AND ACI 318.
2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185 DELIVERED IN FLAT SHEETS.
3. THE CONTRACTOR SHALL REVIEW ALL DRAWINGS FOR SIZE AND LOCATION OF ALL
EMBEDDED ITEMS, SLEEVES, SLAB DEPRESSIONS, OPENINGS, ETC. REQUIRED BY OTHER
TRADES. RECONCILE THEIR EXACT SIZES AND LOCATIONS BEFORE PROCEEDING WITH THE
WORK. ALL ITEMS SHALL BE FURNISHED AND INSTALLED PRIOR TO PLACEMENT OF
CONCRETE. SECURE THE APPROVAL OF THE STRUCTURAL ENGINEER PRIOR TO PLACING
OPENINGS NOT SHOWN ON THE STRUCTURAL DRAWINGS. DO NOT CORE DRILL THROUGH
BEAMS, JOISTS, GIRDERS, OR WALLS. NO CONDUIT SHALL BE PLACED IN CONCRETE SLABS
OR BEAMS UNLESS SPECIFICALLY SHOWN ON THE STRUCTURAL DRAWINGS.
4. BACKFILL AGAINST WALLS SHALL NOT BE PLACED UNTIL THE FLOOR CONSTRUCTION AT THE
FIRST FLOOR HAS BEEN COMPLETED TO BRACE THE WALL. AT THE CONTRACTORS OPTION,
WALLS MAY BE BRACED AND BACKFILL INSTALLED. ANY SUCH BRACING SHALL BE SOLELY
THE RESPONSIBILITY OF THE CONTRACTOR AND SHALL REMAIN IN PLACE UNTIL THE FIRST
FLOOR IS COMPLETED AND CONTINUOUSLY CONNECTED TO THE WALL.
5. WHERE BAR LENGTHS ARE GIVEN ON THE DRAWINGS, THE LENGTH OF ANY HOOK, IF
REQUIRED, IS NOT INCLUDED. USE STANDARD 90° BAR HOOK UNO.
6. PROVIDE HORIZONTAL CONTROL/CONSTRUCTION JOINTS IN SLABS AND VERTICAL
CONTROL/CONSTRUCTION IN WALLS AS SHOWN ON THE DRAWINGS. CONTRACTOR SHALL
SUBMIT ALTERNATE AND ADDITIONAL CONSTRUCTION JOINT LOCATIONS AND DETAILS TO
THE A/E FOR APPROVAL PRIOR TO CONSTRUCTION. AT LEAST 48 HOURS SHALL ELAPSE
BETWEEN CASTING OF ADJOINING UNITS. REINFORCEMENT SHALL BE CONTINOUS ACROSS
CONSTRUCTION JOINTS UNLESS DETAILED OTHERWISE ON THE DRAWINGS. SUBMIT ALL
CONSTRUCTION JOINT LOCATIONS WITH THE REINFORCING SHOP DRAWINGS.
7. WHERE CONSTRUCTION JOINTS ARE REQUIRED BUT ARE NOT INDICIATED ON THE DRAWINGS, THEY SHALL BE LOCATED AT THE MID-SPAN OF BEAMS, SLABS AND WALLS, AND SHALL BE
SUBJECT TO REVIEW BY THE A/E. UNO OR SHOWNG ON THE DRAWINGS, PROVIDE A
CONTINUOUS SHEAR KEY IN SLABS AND WALLS, AND A MINIMUM OF (2) CONTINOUS
HORIZONTAL KEYS IN BEAMS AND EACH JOIST. THE MINIMUM KEY SIZE SHALL BE 1-1/2"
DEEP X 1/3 THE DEPTH OR WIDTH OF THE MEMBER. AT COMPOSITE CONCRETE SLABS ON
STEEL DECK, SUPPORTED BY STEEL BEAMS AND GIRDERS, CONSTRUCTION JOINTS PARALLEL
TO BEAMS SHALL BE PLACED MID-WAY BETWEEN BEAMS NEAREST TO THE COLUMN
CENTERLINE AND CONSTRUCTION JOINTS PARALLEL TO GIRDERS SHALL BE PLACED 4 TO 6
FEET FROM THE GIRDER CENTERLINE. AT NON-COMPOSITE CONCRETE SLABS ON STEEL
DECK, SUPPORTED BY STEEL BEAMS AND GIRDERS, CONSTRUCTION JOINTS SHALL BE
PLACED AT MID-SPAN OF DECK AND MID-WAY BETWEEN GIRDERS. REFERENCE ACI 302 FOR
GUIDELINES AND ADDITIONAL INFORMATION.
8. THE CONTRACTOR SHALL PROVIDE 3/4" CHAMFERS ON ALL EXPOSED CORNERS OF
COLUMNS, BEAMS, AND WALLS UNO INDICATED ON THE ARCHITECTURAL DRAWINGS.
MINIMUM CLEARANCES FOR REINFORCING STEEL SHALL CONFORM WITH THE TYPICAL
REINFORCING BAR CLEARANCE TABLE.
9. THE HARDENED CONCRETE OF HORIZONTAL CONSTRUCTION JOINTS SHALL BE DAMPENED
AND THEN THOROUGHLY COVERED WITH A COAT OF CEMENT GROUT OF SIMILAR
PROPORTIONS TO THE MORTAR IN THE CONCRETE. THE FRESH CONCRETE SHALL BE PLACED
BEFORE THE GROUT HAS ATTAINED ITS INITIAL SET.
10. THE HARDENED CONCRETE OF CONSTRUCTION JOINTS SHALL BE THOROUGHLY COATED
WITH A BONDING AGENT (SIKA ARMATEC 110 OR EQUAL).
11. WELDING OF REINFORCING STEEL IS NOT PERMITTED.
12. COMPLY WITH THE ARCHITECTURAL DRAWINGS FOR LOCATION AND EXTENT OF SPECIAL
FINISHES OR TREATMENTS TO EXPOSED CONCRETE.
13. PROVIDE 6X6-W1.4XW1.4 WELDED WIRE FABRIC IN ALL TOPPING SLABS, UNO.
14. LAP WELDED WIRE FABRIC 1 SPACE (2 CROSS WIRES) + 2" AT ALL EDGES AND ENDS OF
SHEETS.
15. REINFORCING BAR LAP SPLICES AND ANCHORAGE LENGTHS SHALL CONFORM WITH
"MINIMUM LAP SPLICE AND ANCHORAGE DIMENSION TABLE"
16. PROVIDE A BOND-BREAKER AT MASONRY BEARING OF ALL CAST-IN-PLACE CONCRETE
SLABS, JOISTS, AND BEAMS.
ZONE 1
27.4, -67.3
25.1, -65.0
23.4, -63.3
21.7, -61.6
21.7, -61.6
ZONE 2
27.4, -112.9
25.1, -97.0
23.4, -85.0
21.7, -73.0
21.7, -73.0
ZONE 3
27.4, -170.0
25.1, -131.4
23.4, -102.2
21.7, -73.0
21.7, -73.0
AREA
INTERIOR ZONE
60.7, -65.7
58.0, -63.1
54.4, -59.5
52.5, -57.7
45.5, -50.6
EDGE ZONE
60.7, -80.8
58.0, -74.9
54.4, -68.4
52.5, -64.0
45.5, -50.6
AREA
STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL CONFORM TO THE AISC "SPECIFICATION FOR DESIGN,
FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS".
2. THE STRUCTURE WAS DESIGNED USING LRFD APPROACH PER THE AISC "STEEL
CONSTRUCTION MANUAL"
3. WELDED CONNECTIONS SHALL CONFORM TO THE AWS D1.1.
4. ALL STRUCTURAL STEEL, BOLTS, ETC., SHALL BE DOMESTICALLY PRODUCED.
5. BOLTS AND BOLTED CONNECTIONS SHALL CONFORM TO THE REQUIREMENTS OF THE
"SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS" AS
APPROVED BY THE COUNCIL ON RIVETED AND BOLTED JOINTS, UNO. USE BEARING-TYPE
BOLTS WITH THREADS INCLUDED IN THE SHEAR PLANE. ANCHOR BOLTS SHALL CONFORM TO
ASTM F-1554, GRADE 36, OR AS SPECIFIED ON THE DRAWINGS.
6. WELDING ELECTRODES SHALL BE E70XX (LOW HYDROGEN) OR BETTER, FOR WELDING
SYMBOLS WITH NO LENGTH DIMENSION GIVEN, THE WELDING SHALL BE CONTINUOUS
BETWEEN ABRUPT CHANGES IN DIRECTION. WELDS NOT OTHERWISE NOTED SHALL BE 1/4" IN
SIZE.
7. IN GENERAL, IT IS THE INTENT OF THESE PLANS AND SPECIFICATIONS THAT ALL SHOP
CONNECTIONS BE WELDED AND ALL FIELD CONNECTIONS BE BOLTED EXCEPT WHERE NOTED
OTHERWISE.
8. ALL BOLTS SHALL BE TIGHTENED TO A "SNUG-TIGHT" CONDITION, UNO. BOLTS IN MOMENT
CONNECTIONS SHALL BE DESIGNED "SLIP-CRITICAL" WITH A CLASS "A" FAYING SURFACE.
9. UNLESS NOTED OTHERWISE, TYPICAL BEAM SHEAR CONNECTIONS SHALL BE DETAILED WITH
STANDARD DOUBLE ANGLE OR SHEAR PLATE CONNECTIONS, USING A325 BOLTS.
NON-COMPOSITE BEAM CONNECTIONS SHALL BE DESIGNED TO DEVELOP 55% OF THE
TOTAL LOAD CAPACITY DERIVED FROM THE AISC STEEL CONSTRUCTION MANUAL
MAXIMUM UNIFORM LOAD TABLES.
10. VERIFY THE EXACT SIZE AND LOCATION OF ALL OPENINGS PRIOR TO FABRICATION OF STEEL
FRAMING MEMBERS.
11. PROVIDE A NON-METALLIC, NON-SHRINK GROUT UNDER ALL COLUMN BASE PLATES AND
BEAM BEARINGS.
12. ALL STEEL EXPOSED TO WEATHER, EXPOSED TO EARTH, EXPOSED TO VIEW OUTSIDE THE
BUILDING ENVELOPE, OR DENOTED ON THE DRAWINGS TO BE GALVANIZED, SHALL BE HOT-
DIPPED GALVANIZED AFTER FABRICATION. GALVANIZING SHALL BE REMOVED PER AWS
D-19.0, "WELDING ZINC-COATED STEEL", PRIOR TO FIELD WELDING. WELDS SHALL BE
TOUCHED-UP WITH TWO COATS OF ZINC-RICH PAINT BRUSH APPLIED USING ZRC
GALVANIZING COMPOUND OR EQUAL. PROVIDE VENT/DRAINAGE HOLES IN HSS MEMBERS
(MINIMUM 3/4 DIAMETER, BOTTOM SIDE OF HORIZONTAL MEMBERS, WITHIN 2" OF BASE
FOR VERTICAL MEMBERS) PRIOR TO GALVANIZING.
13. ALL STEEL WITHIN UNCONDITIONED AREAS OUTSIDE THE BUILDING ENVELOPE (E.G.
EXTERIOR SOFFITS, CANOPIES, ETC) BUT NOT EXPOSED TO VIEW SHALL BE PRIMED AND
PAINTED UNLESS NOTED OTHERWISE.
STEEL DECK
1. STEEL DECK FABRICATION AND ERECTION SHALL CONFORM TO THE STEEL DECK INSTITUTE
SPECIFICATIONS.
2. DECK SHALL INCLUDE ANY MISCELLANEOUS CLOSURE PIECES, METAL SCREEDS, ROOF
CURBS, DRAIN SUMP PANS, REINFORCING AROUND OPENINGS, ETC. REQUIRED TO MAKE A
COMPLETE JOB. MISCELLANEOUS ITEMS SHALL BE GALVANIZED AND SHALL BE NO THINNER
THAN 18 GAGE.
3. DUE ALLOWANCE SHALL BE MADE FOR DEFLECTION OF UNSHORED SLABS. NO ADDITIONAL
PAYMENTS WILL BE MADE FOR EXTRA CONCRETE USED TO FINISH SURFACES TO REQUIRED
ELEVATIONS.
4. ROOF DECK SHALL BE PRIME PAINTED, UNO.
5. NO LOAD SHALL BE HUNG FROM STEEL ROOF DECK.
PRECAST CONCRETE
1. PRECAST CONCRETE WORK SHALL CONFORM TO THE AMERICAN CONCRETE INSTITUTE AND
THE PRECAST/PRESTRESSED CONCRETE INSTITUTE CODES AND STANDARDS LISTED IN THE
PROJECT MANUAL, EXCEPT AS MODIFIED THEREIN.
2. MINIMUM COMPRESSIVE STRENGTH OF CONCRETE AT 28 DAYS (f'c) SHALL BE 5,000 PSI.
3. REINFORCING BARS SHALL BE ASTM A615, fy = 60,000 PSI, UNO.
4. PRECAST MEMBERS SHALL BE DESIGNED BY THE MANUFACTURER FOR THE LOADS GIVEN IN
THESE DRAWINGS.
5. THE PRECAST MANUFACTURER SHALL COORDINATE SIZE AND LOCATION OF ALL OPENINGS
IN PRECAST MEMBERS WITH ALL OTHER TRADES.
6. ALL OPENINGS LARGER THAN 10" SQUARE OR ROUND SHALL BE PROVIDED BY THE PRECAST
MANUFACTURER, SMALLER OPENINGS MAY BE FIELD CUT OR CORED BY THE TRADES
REQUIRING THE OPENINGS ONLY AFTER WRITTEN APPROVAL FROM THE PRECAST
MANUFACTURER.
7. PROVIDE CAST-IN DOVETAIL SLOTS IN PRECAST WALL PANELS FOR ANCHORING OF BRICK
VENEER WHERE PRESENT. SEE ARCHITECTURAL DRAWINGS FOR ALL LOCATIONS OF BRICK
VENEER.
FOUNDATIONS
1. FOUNDATIONS HAVE BEEN DESIGNED IN ACCORDANCE WITH THE SUBSURFACE
INVESTIGATION REPORT BY SME DATED AUGUST 17, 2021. THE CONTRACTOR SHALL
BECOME FAMILIAR WITH THE SURVEY AND SUBSURFACE INVESTIGATION REPORT PRIOR TO
BIDDING AND BEFORE BEGINNING CONSTRUCTION.
2. THE SUBSURFACE INVESTIGATION IS FOR INFORMATIONAL PURPOSES ONLY AND SHALL NOT
BE CONSIDERED PART OF THE CONTRACT DOCUMENTS. FURTHERMORE, NO WARRANTY IS
MADE BY THE OWNER WITH REGARD TO COMPLETENESS AND ACCURACY OF SUBSURFACE
INVESTIGATION DATA, STATEMENTS, AND INTERPRETATIONS GIVEN IN REPORT.
3. NOTIFY THE A/E AS SOON AS POSSIBLE OF ANY UNUSUAL SOIL CONDITIONS OR SOIL
CONDITIONS AT VARIANCE WITH TEST BORINGS, SUCH AS UNEXPECTED SPRING OR
SEEPAGE WATER, MATERIAL DIFFERING FROM TEST BORINGS, OR SOIL OF QUESTIONABLE
BEARING CAPACITY.
4. SET FOUNDATIONS AT THE ELEVATIONS SHOWN ON THE DRAWINGS ON FIRM SUBGRADE
PREPARED PER THE EARTHWORK SPECIFICATIONS. VERIFY THAT EACH FOOTING PLACED IS
BEARING ON MATERIAL WITH THE DESIGN BEARING CAPACITY PER THE SUBSURFACE
INVESTIGATIVE REPORT.
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN, INSTALLATION, AND FINAL
CLEARANCE OF ANY REQUIRED NEEDLING, UNDERPINNING, SHORING, OR BRACING OF
EXISTING STRUCTURES.
SLAB AND METAL DECK LEGEND
R1 DENOTES SPAN DIRECTION FOR 1-1/2" x 20 GAUGE WIDE RIB
METAL ROOF DECK. FASTEN TO SUPPORTING MEMBERS WITH
5/8" PUDDLE WELDS IN 36/4 PATTERN. INSTALL #10 SELF-
DRILLING SCREW SIDELAP FASTENERS @24" MAX SPACING
BETWEEN SUPPORTS.
1 2 3 4 5 7
A A
B
C
E
F
G
D
1 1
SNOW DRIFT SCHEDULE
DRIFT Wd Pd NOTES
1 8' - 6" 46 PSF
NOTES:
1. SNOW DRIFT VALUES INDICATED ARE IN ADDITION TO FLAT ROOF SNOW LOAD.
2. ONLY DRIFTS ON NEW CONSTRUCTION OR DRIFTS ON EXISTING CONSTRUCTION CAUSED
OR IMPACTED BY NEW CONSTRUCTION ARE...
FLAT ROOF SNOW LOAD PER GENERAL NOTESP
P
ROOF LINEWd d f
CONCRETE REINFORCING CLEAR COVER REQUIREMENTS
CONCRETE CAST AGAINST AND PERMANENTLY IN CONTACT WITH GROUND
CONCRETE EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
#5 BAR AND SMALLER
#6 BAR AND LARGER
CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND
SLABS, JOISTS, AND WALLS (NOT LARGER THAN #11 BAR)
BEAMS, COLUMNS, PIERS
NOTE:
CLEAR COVER DIMENSIONS LISTED ARE CODE-REQUIRED MINIMUMS. PROVIDE GREATER
COVER WHERE SPECIFICALLY REQUIRED BY DETAILS.
3"
1-1/2"
2"
3/4"
1-1/2"
USE THIS TABLE FOR A615 GRADE 60 REINFORCING WHEN CONCRETE CLEAR COVER AND
CLEAR SPACING IS AT LEAST db AND CODE MINIMUM STIRRUPS ARE PROVIDED OR IF
MINIMUM STIRRUPS ARE NOT PROVIDED, CLEAR SPACING IS AT LEAST 2db.
CONCRETE MINIMUM LAP SPLICE AND
ANCHORAGE DIMENSION TABLE
(4000 PSI CONCRETE) (3000 PSI CONCRETE)
TOP BARS OTHER BARS TOP BARS OTHER BARSBAR SIZE BAR SIZE
DEVELOPMENT LENGTH
#3
#4
#5
#6
#7
#8
#10
#9
#11
#3
#4
#5
#6
#7
#8
#10
#9
#11
15"
20"
25"
30"
44"
50"
63"
56"
12"
16"
19"
23"
34"
38"
49"
43"
54"
18"
23"
29"
35"
50"
57"
73"
65"
81"
14"
18"
22"
27"
39"
44"
56"
50"
62"
NOTES:
• LAP LENGTHS SHALL BE 1.3 TIMES DEVELOPMENT LENGTH.
• FOR EPOXY COATED REINFORCING MULTIPLY THE TABLE VALUES ABOVE BY 1.5.
• (MC) DENOTES MECHANICAL COUPLER DEVELOPING 125% OF THE BAR YIELD STRENGTH.
NO OTHER SPLICE WILL BE ACCEPTED.
• WHEN LAPPING TWO DIFFERENT SIZE BARS, USE THE LAP DIMENSION OF THE SMALLER
BAR OR THE ANCHORAGE DIMENSION OF THE LARGER BARS. USE WHICHEVER DIMENSION
IS LARGER.
• TOP BARS SHALL BE DEFINED AS BEAM AND SLAB HORIZONTAL REINFORCEMENT SO
PLACED THAT MORE THAN 12" OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE
TOP REINFORCEMENT. HORIZONTAL REINFORCING IN WALLS SHALL BE CONSIDERED TOP
BARS.
DEVELOPMENT LENGTH
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
G E
N E
R A
L N
O T
E S
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
3/32" = 1'-0"
SNOW DRIFT PLAN ISSUED FOR DATE
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
/2
.T
A P
A U
G U
S T
REQUIRED SPECIAL INSPECTIONS AND TESTS OF SOILS (MBC SECTION 1705.6)
SPECIAL INSPECTION TASK
CONTINUOUS SPECIAL
INSPECTION
PERIODIC SPECIAL
INSPECTION
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE ADEQUATE TO ACHIEVE
THE DESIGN BEARING CAPACITY.
2. VERIFY EXCAVATIONS ARE EXTENDED TO THE PROPER DEPTH AND HAVE REACHED
PROPER MATERIAL.
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL MATERIALS.
4. VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT THICKNESSES DURING
PLACEMENT AND COMPACTION OF COMPACTED FILL.
5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE AND VERIFY
THAT SITE HAS BEEN PREPARED PROPERLY.
X
X
X
X
X
REQUIRED SPECIAL INSPECTIONS AND TESTS OF CONCRETE CONSTRUCTION (MBC SECTION 1705.3)
SPECIAL INSPECTION TASK
CONTINUOUS SPECIAL
INSPECTION
PERIODIC SPECIAL
INSPECTION
1. INSPECT REINFORCEMENT, INCLUDING PRESTRESSING TENDONS AND VERIFY
PLACEMENT.
2. REINFORCING BAR WELDING (PERMITTED ONLY WHEN SPECIFICALLY SHOWN IN THE
DETAILS OR WITH PERMISSION IN WRITING BY THE ENGINEER):
A. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN ASTM A706
B. INSPECT SINGLE-PASS FILLET WELDS UP TO AND INCLUDING 5/16"
C. INSPECT ALL OTHER WELDS
3. INSPECT ANCHORS CAST IN CONCRETE
4. INSPECT ANCHORS POST-INSTALLED IN HARDENED CONCRETE
A. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR UPWARDLY INCLINED
ORIENTATIONS TO RESIST SUSTAINED TENSION LOADS
B. ALL OTHER ANCHORS POST-INSTALLED IN HARDENED CONCRETE
5. VERIFY USE OF REQUIRED MIX DESIGN.
6. PRIOR TO CONCRETE PLACEMENT, FABRICATE SPECIMENS FOR STRENGTH TESTS,
PERFORM SLUMP AND AIR CONTENT TESTS, AND DETERMINE THE TEMPERATURE
OF THE CONCRETE.
7. INSPECT CONCRETE PLACEMENT FOR PROPER APPLICATION TECHNIQUES.
8. VERIFY MAINTENANCE OF SPECIFIED CURING TEMPERATURE AND TECHNIQUES.
9. INSPECT PRESTRESSED CONCRETE FOR:
A. APPLICATION OF PRESTRESSING FORCES; AND
B. GROUTING OF BONDED PRESTRESSING TENDONS.
10. INSPECT ERECTION OF PRECAST CONCRETE MEMBERS.
11. VERIFY IN-SITU CONCRETE STRENGTH PRIOR TO REMOVAL OF SHORES AND
FORMS FROM BEAMS AND STRUCTURAL SLABS.
12. INSPECT FORMWORK FOR SHAPE, LOCATION AND DIMENSIONS OF CONCRETE
MEMBER BEING FORMED.
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
EXCEPTIONS - THE ABOVE SPECIAL INSPECTIONS AND TESTS SHALL NOT BE REQUIRED FOR THE FOLLOWING BUILDING ELEMENTS:
1. ISOLATED SPREAD FOOTINGS OF BUILDINGS THREE STORIES OR LESS ABOVE GRADE THAT ARE FULLY SUPPORTED ON EARTH OR ROCK.
2. NONSTRUCTURAL SLABS SUPPORTED DIRECTLY ON THE GROUND.
REQUIRED SPECIAL INSPECTIONS PRIOR TO WELDING OF STRUCTURAL STEEL (AISC 360 N5.4)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. WELDER QUALIFICATION RECORDS AND CONTINUITY RECORDS
2. WPS AVAILABLE
3. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
4. MATERIAL IDENTIFICATION (TYPE/GRADE)
5. WELDER IDENTIFICATION SYSTEM
6. FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY)
A. JOINT PREPARATIONS
B. DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL)
C. CLEANLINESS (CONDITION OF STEEL SURFACES)
D. TACKING (TACK WELD QUALITY AND LOCATION)
E. BACKING TYPE AND FIT (IF APPLICABLE)
7. CONFIGURATION AND FINISH OF ACCESS HOLES
8. FIT-UP OF FILLET WELDS
A. DIMENSIONS (ALIGNMENT, GAPS AT ROOT)
B. CLEANLINESS (CONDITION OF STEEL SURFACES)
C. TACKING (TACK WELD QUALITY AND LOCATION)
X
X
X
X
X
X
X
X
REQUIRED SPECIAL INSPECTIONS DURING WELDING OF STRUCTURAL STEEL (AISC 360 N5.4)
SPECIAL INSPECTION TASK
1. CONTROL AND HANDLING OF WELDING CONSUMABLES
A. PACKAGING
B. EXPOSURE CONTROL
2. NO WELDING OVER CRACKED TACK WELDS
3. ENVIRONMENTAL CONDITIONS
A. WIND SPEED WITHIN LIMITS
B. PRECIPITATION AND TEMPERATURE
4. WPS FOLLOWED
A. SETTINGS ON WELDING EQUIPMENT
B. TRAVEL SPEED
C. SELECTED WELDING MATERIALS
D. SHIELDING GAS TYPE/FLOW RATE
E. PREHEAT APPLIED
F. INTERPASS TEMPERATURE MAINTAINED (MIN./MAX.)
G. PROPER POSITION (F, V, H, OH)
5. WELDING TECHNIQUES
A. INTERPASS AND FINAL CLEANING
B. EACH PASS WITHIN PROFILE LIMITATIONS
C. EACH PASS MEETS QUALITY REQUIREMENTS
6. PLACEMENT AND INSTALLATION OF STEEL HEADED STUD ANCHORS
X
X
X
X
X
X
REQUIRED SPECIAL INSPECTIONS AFTER WELDING OF STRUCTURAL STEEL (AISC 360 N5.4)
SPECIAL INSPECTION TASK
1. WELDS CLEANED
2. SIZE, LENGTH, AND LOCATION OF WELDS
3. WELDS MEET VISUAL ACCEPTANCE CRITERIA
A. CRACK PROHIBITION
B. WELD/BASE-METAL FUSION
C. CRATER CROSS SECTION
D. WELD PROFILES
E. WELD SIZE
F. UNDERCUT
G. POROSITY
4. ARC STRIKES
5. k-AREA
6. WELD ACCESS HOLES IN ROLLED HEAVY SHAPES AND BUILT-UP HEAVY SHAPES
7. BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)
8. REPAIR ACTIVITIES
9. DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER
10. NO PROHIBITED WELDS HAVE BEEN ADDED WITHOUT THE APPROVAL OF THE EOR
X
X
X
X
X
X
X
X
X
X
REQUIRED SPECIAL INSPECTIONS PRIOR TO BOLTING OF STRUCTURAL STEEL (AISC 360 N5.6)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. MANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS
2. FASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS
3. CORRECT FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT
LENGTH IF THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)
4. CORRECT BOLTING PROCEDURE SELECTED FOR JOINT DETAIL
5. CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE
CONDITION AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE
REQUIREMENTS
6. PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL
OBSERVED AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED
(REQUIRED ONLY FOR PRETENSIONED OR SLIP-CRITICAL JOINTS)
7. PROTECTED STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER
FASTENER COMPONENTS
X
X
X
X
X
X
X
REQUIRED SPECIAL INSPECTIONS DURING BOLTING OF STRUCTURAL STEEL (AISC 360 N5.6)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. FASTENER ASSEMBLIES PLACED IN ALL HOLES AND WASHERS AND NUTS ARE
POSITIONED AS REQUIRED.
2. JOINT BROUGHT INTO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING
OPERATION.
3. FASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM
ROTATING.
4. FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION,
PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE
EDGES (REQUIRED ONLY FOR PRETENSIONED OR SLIP-CRITICAL JOINTS)
X
X
X
X
REQUIRED SPECIAL INSPECTIONS AFTER BOLTING OF STRUCTURAL STEEL (AISC 360 N5.6)
SPECIAL INSPECTION TASK
1. DOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS X -
OTHER REQUIRED SPECIAL INSPECTIONS OF STRUCTURAL STEEL (AISC 360 N5.7 AND N5.8)
SPECIAL INSPECTION TASK
1. VISUALLY INSPECT EXPOSED CUT SURFACES OF GALVANIZED STRUCTURAL STEEL MAIN MEMBERS AND EXPOSED CORNERS OF
RECTANGULAR HSS FOR CRACKS SUBSEQUENT TO GALVANIZING.
2. DURING PLACEMENT OF ANCHOR RODS AND OTHER EMBEDMENTS SUPPORTING STRUCTURAL STEEL, VERIFY AND DOCUMENT THE
DIAMETER, GRADE, TYPE AND LENGTH OF THE ANCHOR ROD OR EMBEDDED ITEM, AND THE EXTENT OR DEPTH OF EMBEDMENT INTO
THE CONCRETE PRIOR TO PLACEMENT OF CONCRETE.
3. INSPECT THE FABRICATED STEEL OR ERECTED STEEL FRAME, AS APPLICABLE, TO VERIFY COMPLIANCE WITH THE DETAILS SHOWN ON
THE CONSTRUCTION DOCUMENTS. THIS INCLUDES SUCH ITEMS AS BRACES, STIFFENERS, MEMBER LOCATIONS, AND THE CORRECT
APPLICATION OF JOINT DETAILS AT EACH CONNECTION.
REQUIRED NONDESTRUCTIVE TESTING OF WELDED JOINTS IN STRUCTURAL STEEL (AISC 360 N5.5)
TESTING TASK
1. ULTRASONIC TESTING OF COMPLETE-JOINT-PENETRATION (CJP) GROOVE WELDS SUBJECT TO TRANSVERSELY APPLIED TENSION
LOADING IN BUTT, T- AND CORNER JOINTS, IN MATERIAL 5/16" THICK OR GREATER
A. ULTRASONIC TESTING SHALL BE PERFORMED ON 10% OF SUCH WELDS IN STRUCTURES IN RISK CATEGORY II
B. ULTRASONIC TESTING SHALL BE PERFORMED ON 100% OF SUCH WELDS IN STRUCTURES IN RISK CATEGORY III OR IV
C. REFER TO AISC 360 SECTION N5.5 FOR CONDITIONS WHERE THE RATE OF ULTRASONIC TESTING IS PERMITTED TO BE REDUCED
D. REFER TO AISC 360 SECTION N5.5 FOR CONDITIONS WHERE THE RATE OF ULTRASONIC TESTING IS REQUIRED TO BE INCREASED
PERFORM OBSERVE
PERFORM OBSERVE
PERFORM OBSERVE
REQUIRED SPECIAL INSPECTIONS PRIOR TO STEEL DECK PLACEMENT (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. VERIFY COMPLIANCE OF MATERIALS (DECK AND ALL DECK ACCESSORIES) WITH
CONSTRUCTION DOCUMENTS, INCLUDING PROFILES, MATERIAL PROPERTIES, AND
BASE METAL THICKNESS
2. DOCUMENT ACCEPTANCE OR REJECTION OF DECK AND DECK ACCESSORIES
X
X
REQUIRED SPECIAL INSPECTIONS AFTER STEEL DECK PLACEMENT (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. VERIFY COMPLIANCE OF DECK AND ALL DECK ACCESSORIES INSTALLATION WITH
CONSTRUCTION DOCUMENTS
2. VERIFY DECK MATERIALS ARE REPRESENTED BY THE MILL CERTIFICATIONS THAT
COMPLY WITH THE CONSTRUCTION DOCUMENTS
3. DOCUMENT ACCEPTANCE OR REJECTION OF INSTALLATION OF DECK AND DECK
ACCESSORIES
X
X
X
REQUIRED SPECIAL INSPECTIONS PRIOR TO WELDING OF STEEL DECK (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. WELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE
2. MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
3. MATERIAL IDENTIFICATION (TYPE/GRADE)
4. CHECK WELDING EQUIPMENT
X
X
X
X
REQUIRED SPECIAL INSPECTIONS DURING WELDING OF STEEL DECK (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. USE OF QUALIFIED WELDERS
2. CONTROL AND HANDLING OF WELDING CONSUMABLES
3. ENVIRONMENTAL CONDITIONS (WIND SPEED, MOISTURE, TEMPERATURE)
4. WPS FOLLOWED
X
X
X
X
REQUIRED SPECIAL INSPECTIONS AFTER WELDING OF STEEL DECK (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. VERIFY SIZE AND LOCATION OF WELDS, INCLUDING SUPPORT, SIDELAP, AND
PERIMETER WELDS
2. WELDS MEET VISUAL ACCEPTANCE CRITERIA
3. VERIFY REPAIR ACTIVITIES
4. DOCUMENT ACCEPTANCE OR REJECTION OF WELDS
X
X
X
X
REQUIRED SPECIAL INSPECTIONS PRIOR TO MECHANICAL FASTENING OF STEEL DECK (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. MANUFACTURER INSTALLATION INSTRUCTIONS AVAILABLE FOR MECHANICAL
FASTENERS
2. PROPER TOOLS AVAILABLE FOR FASTENER INSTALLATION
3. PROPER STORAGE FOR MECHANICAL FASTENERS
X
X
X
REQUIRED SPECIAL INSPECTIONS DURING MECHANICAL FASTENING OF STEEL DECK (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. FASTENERS ARE POSITIONED AS REQUIRED
2. FASTENERS ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S
INSTRUCTIONS
X
X
REQUIRED SPECIAL INSPECTIONS AFTER MECHANICAL FASTENING OF STEEL DECK (SDI QA/QC)
SPECIAL INSPECTION TASK PERFORM OBSERVE
1. CHECK SPACING, TYPE, AND INSTALLATION OF SUPPORT FASTENERS
2. CHECK SPACING, TYPE, AND INSTALLATION OF SIDELAP FASTENERS
3. CHECK SPACING, TYPE, AND INSTALLATION OF PERIMETER FASTENERS
4. VERIFY REPAIR ACTIVITIES
5. DOCUMENT ACCEPTANCE OR REJECTION OF MECHANICAL FASTENERS
X
X
X
X
X
GENERAL NOTES REGARDING SPECIAL INSPECTIONS AND TESTS
1. SPECIAL INSPECTIONS ARE IN ADDITION TO INSPECTIONS BY THE BUILDING OFFICIAL THAT ARE IDENTIFIED IN SECTION 110 OF THE
MICHIGAN BUILDING CODE. SPECIAL INSPECTIONS DO NOT RELIEVE THE CONTRACTOR FROM COMPLYING WITH THE CONTRACT
DOCUMENTS.
2. CONTINUOUS SPECIAL INSPECTION IS DEFINED AS SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS PRESENT
CONTINUOUSLY WHEN AND WHERE THE WORK TO BE INSPECTED IS BEING PERFORMED.
3. PERIODIC SPECIAL INSPECTION IS DEFINED AS SPECIAL INSPECTION BY THE SPECIAL INSPECTOR WHO IS INTERMITTENTLY PRESENT
WHERE THE WORK TO BE INSPECTED HAS BEEN OR IS BEING PERFORMED. THE FREQUENCY OF THESE SPECIAL INSPECTION TASKS
SHALL BE ADEQUATE TO DETERMINE THAT WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION
DOCUMENTS.
4. WHERE A SPECIAL INSPECTION TASK IS NOTED AS "OBSERVE," THE SPECIAL INSPECTOR SHALL OBSERVE THESE ITEMS ON A RANDOM
BASIS. OPERATIONS NEED NOT BE DELAYED PENDING THESE INSPECTIONS. THE FREQUENCY OF THESE SPECIAL INSPECTION TASKS
SHALL BE ADEQUATE TO DETERMINE THAT THE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH THE APPROVED CONSTRUCTION
DOCUMENTS.
5. WHERE A SPECIAL INSPECTION TASK IS NOTED AS "PERFORM," THE TASK SHALL BE PERFORMED FOR EACH MEMBER, JOINT, OR
ELEMENT PRIOR TO FINAL ACCEPTANCE.
6. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON EMPLOYED OR RETAINED BY AN APPROVED AGENCY AND APPROVED BY THE
BUILDING OFFICIAL AS HAVING THE COMPETENCE NECESSARY TO INSPECT A PARTICULAR TYPE OF CONSTRUCTION REQUIRING
SPECIAL INSPECTION.
7. PRIOR TO THE START OF CONSTRUCTION, THE APPROVED SPECIAL INSPECTION AGENCY SHALL SUBMIT WRITTEN DOCUMENTATION
TO THE BUILDING OFFICIAL DEMONSTRATING THE COMPETENCE AND RELEVANT EXPERIENCE OR TRAINING OF THE SPECIAL
INSPECTORS WHO WILL PERFORM THE SPECIAL INSPECTIONS AND TESTS DURING CONSTRUCTION.
8. THE CONSTRUCTION OR WORK FOR WHICH SPECIAL INSPECTION OR TESTING IS REQUIRED SHALL REMAIN ACCESSIBLE AND EXPOSED
FOR SPECIAL INSPECTION OR TESTING PURPOSES UNTIL COMPLETION OF REQUIRED SPECIAL INSPECTIONS OR TESTS. SEE
SPECIFICATION FOR ADDITIONAL REQUIREMENTS, INCLUDING CONTRACTOR'S RESPONSIBILITY TO PROVIDE ACCESS FOR SPECIAL
INSPECTIONS AND CONTRACTOR'S RESPONSIBILITY TO PROVIDE DUE NOTICE TO SPECIAL INSPECTOR PRIOR TO THE TIME THAT
SPECIAL INSPECTION IS REQUIRED.
9. SPECIAL INSPECTION AGENCY SHALL KEEP RECORDS OF SPECIAL INSPECTIONS AND TESTS AND SHALL SUBMIT REPORTS OF SPECIAL
INSPECTIONS AND TESTS TO THE BUILDING OFFICIAL AND TO THE ENGINEER. REPORTS SHALL INDICATE THAT WORK INSPECTED OR
TESTED WAS OR WAS NOT COMPLETED IN CONFORMANCE TO APPROVED CONSTRUCTION DOCUMENTS. DISCREPANCIES SHALL BE
BROUGHT TO THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION. IF THEY ARE NOT CORRECTED, THE
DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE BUILDING OFFICIAL AND TO THE ENGINEER PRIOR TO THE
COMPLETION OF THAT PHASE OF THE WORK. A FINAL REPORT DOCUMENTING REQUIRED SPECIAL INSPECTIONS AND TESTS, AND
CORRECTION OF ANY DISCREPANCIES NOTED IN THE INSPECTIONS AND TESTS, SHALL BE SUBMITTED TO THE BUILDING OFFICIAL.
10. WHERE SPECIAL INSPECTION OF STRUCTURAL MEMBERS OR ASSEMBLIES IS BEING CONDUCTED ON THE PREMISES OF A
FABRICATOR'S SHOP, SPECIAL INSPECTION OF THE FABRICATED ITEMS SHALL BE PERFORMED DURING FABRICATION.
11. SPECIAL INSPECTIONS DURING FABRICATION ARE NOT REQUIRED WHERE THE WORK IS DONE ON THE PREMISES OF A FABRICATOR
REGISTERED AND APPROVED BY THE BUILDING OFFICIAL TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION. UPON THE
COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE OWNER OR THE
OWNER'S AUTHORIZED AGENT FOR SUBMITTAL TO THE BUILDING OFFICIAL STATING THAT THE WORK WAS PERFORMED IN
COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS.
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
S T
A T
E M
E N
T O
F S
P E
C
IA
L I N
S P
E C
T
IO
N S
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
ISSUED FOR DATE
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
/2
.T
A P
A U
G U
S T
EDGE ANGLE OR BENT PLATE-
SEE FRAMING PLANS FOR SIZE
1" DIAMETER A36 ROD x1' - 0" LONG.
CENTER ON SPLICE LOCATION
TYP.
(3/16)
G A P
/2
M
A X.
INSOLATION JOINT WITH
BONDBREAKER ALONG
WALL - TYP
COLUMN
CONTROL JOINT MAX SPAN
SHALL CONFORM WITH
SPECIFICATIONS
INSULATION JOINT WITH
BONDBREAKER AROUND
DIAMOND, TYP
CAST DIAMOND AFTER
SLAB ON GRADE HAS BEEN
CAST SHALL CONFORM
WITH SPECIFICATIONS
/4
T
T
1/8" SAWED JOINT;
FILL WITH JOINT FILLER
NOTE: T = SLAB THK
SEE TYP SLAB ON GRADE DETAIL &
SPECIFICATIONS FOR SUBGRADE
MATERIAL & COMPACTION
TOP OF SLAB
/4
T
T
1/8" SAW-CUT AFTER ADJ SLAB IS IN
PLACE & FILL WITH JOINT FILLER
NOTE: T=SLAB THK
SEE TYP SLAB ON GRADE
DETAIL & SPECIFICATIONS
FOR SUBGRADE MATERIAL
& COMPACTION
TOP OF SLAB
/3
T
KEYED JOINT AT CENTERLINE OF SLAB
/2
T
M
IN
3/4" MIN
1/10T
T T
DISCONTINUE 50%
REINFORCING AT JOINT
WWF
BREAK BOND ON JOINT
FACE WITH 2 COATS OF
FORM RELEASE OIL
TOP OF SLAB
CONCRETE SLAB
ON GRADE
WWF, SEE PLANS
VAPOR BARRIER.
SEE SPECIFICATIONS
DRAINAGE COURSE (FREE
DRAINING POROUS FILL)
COMPACTED SUBGRADE
NOTES:
1. SUBGRADE SHALL BE PREPARED PER THE GEOTECHNICAL REPORT PRIOR TO SLAB PLACEMENT.
UNSUITABLE SUBGRADE SHALL BE REMOVED AND REPLACED WITH AN ENGINEERED FILL OR
ADEQUATE BORROW MATERIAL AND COMPACTED PER THE EARTHWORK SPECIFICATIONS AND
GEOTECHNICAL REPORT RECOMMENDATIONS.
2. SEE GEOTECHNICAL REPORT FOR ADDITIONAL SUBGRADE PREPARATION REQUIREMENTS.
3. SLAB SHALL BE PLACED A MINIMUM OF 90 DAYS PRIOR TO INSTALLATION OF FLOOR FINISHES.
4. WET CURE ALL SLABS ON GRADE, REFER TO SPECIFICATIONS.
/3
T
S
EE
P
LA
N
T
OPTION 1: SETTING PLATE OPTION 2: LEVELING NUTS
AND WASHERS
1/4" SETTING PLATE ON
3/4" NON-SHRINK GROUT
SEE TYPICAL ANCHOR
ROD DETAIL
SEE TYPICAL ANCHOR
ROD DETAIL
PLATE WASHER PER AISC
NON-SHRINK GROUT
M
A
X.PLATE WASHER PER AISC
COLUMN BASE PLATE-
SEE SCHEDULE
COLUMN BASE PLATE-
SEE SCHEDULE
TOP OF FOOTING OR PIER
HEAVY HEX NUT THREADED
ON EMBEDDED END
TACK WELD ON UNDERSIDE OF
NUT TO PREVENT ROTATION
S
EE
B A S E
P
LA
TE
S
C H
ED
U
LE
EM
B
ED
M
EN
T
FULLY THREAD PORTION OF
ROD PROJECTING ABOVE TOP
OF FOOTING OR PIER
SEE BASE PLATE SCHEDULE FOR
ROD DIAMETER
.1 /4
TOP OF JST
OR TOP OF BEAM
CONTR FOR SIZE & LOC
ROOF OPNG SEE MECH
JOIST SPACING PER PLAN
CONNECTION
MEMBER
JOIST REINFORCING
SEE TYP DETAIL
SUP MEMBER
WELD DECK TO
ANGLES
STEEL BEAM OR JOIST
NOTES:
1. ALL WELDING TO JOISTS SHALL BE DONE WITH CARE SO AS TO NOT IMPAIR JOIST.
2. COORDINATE LOCATION AND SIZE OF OPENINGS WITH MECHANICAL CONTRACTOR.
JOIST SPACING SUPPORTING MEMBER CONNECTING MEMBER
MAX 6'-0"
GREATER THAN 6'-0"
L3x3x1/4
L5x3x1/4 LLV
L3x3x1/4x0'-6"
L5x3x1/4 LLV x 6"
3/16
TYP
3/16
TYP
LE
N G
TH
WIDTH
TYP
1 1/2"
TY
P
/2
1/4
NOTE:
REFER TO COLUMN SCHEDULE FOR BASE PLATE AND ANCHOR ROD DIMENSIONS
EQ EQ
EQ
EQ
LE
N G
TH
WIDTH
TYP
1 1/2"
TY
P
/2
1/4
2"
EQ
EQ
TYPE BTYPE A
TY
P
/2
1/4
2"
TYPE C
5 1/2" 3" 1 1/2"
10"
PLACE CONCRETE FILL AROUND
SLEEVE PRIOR TO POURING
FOUNDATION; MAKE SAME WIDTH
AS FOOTING & FULL WIDTH OF
PIPE TRENCH (2'-0" MIN)
M
IN6
H
ER
E
N O
P
IP
ES
M
IN
ALL SLEEVES TO HAVE
1" CLR AROUND PIPE
PIPE
PIPE
WALL SLEEVE
FINISHED GRADE
FOUNDATION
TOP OF SLAB
TOP OF FOOTING
3" MIN CONCRETE COVER
AROUND STRUCTURAL STEEL
G R O
U T
/2 N O
N -S
H R
IN
K
EQ UNO EQ UNO
SEE FOOTING SCHEDULE FOR
SIZE & REINFORCING
INSULATION JOINT AROUND COLUMN
SEE COLUMN SCHEDULE FOR COLUMN
SIZE, BASE PLATE & ANCHOR BOLTS
BEAM END REACTION SCHEDULE
SIZE DEAD LOAD (K) LIVE/SNOW
LOAD (K)
DEAD LOAD
MOMENT (FT*K)
UNFACTORED SHEAR UNFACTORED MOMENT*
LIVE/SNOW LOAD
MOMENT (FT*K)
WIND LOAD
MOMENT (FT*K)
AXIAL (K)
W8/W10 5 3 75 +1 / -6
W16/W24 7 15
NOTES:
1. UNFACTORED LOADS ARE CALCULATED IN ACCORDANCE WITH ASCE 7-10 WITH NO LOAD FACTORS APPLIED, I.E., DEAD, LIVE, AND SNOW LOADS ARE SERVICE-
LEVEL; WIND AND SEISMIC LOADS ARE STRENGTH-LEVEL.
2. * MOMENT CONNECTIONS REQUIRED WHERE INDICATED WITH SYMBOLS ON FRAMING PLAN, SEE FRAMING PLAN LEGEND FOR LOCATIONS.
3 7 +1 / -6
TY
P (3
S
ID
ES
M
IN
3" PREFABRICATED VOID FORM
BENEATH SLAB. SUREVOID SLABVOID
BY VOIDFORM PRODUCTS, INC OR
APPROVED EQUAL
8"
DIMENSION WITH LANDSCAPING PLAN
SEE FOUNDATION PLAN AND COORDINATE
PLAN
SEE
FOUNDATION WALL AND
FOOTING REINFORCEMENT
OMITTED FOR CLARITYCOMPACTED
SUBGRADE
#4@12" EACH WAY,
TYP. THREE SIDES
1" RIGID INSULATION
BELOW DOOR THRESHOLD
#4 BENT BARS
@12" OC
SLOPE
#4@12" EACH WAY
C L R
/2
CONTROL JOINT PATTERN
#4 BENT BARS
@12" OC
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T Y
P
IC
A L D
E T
A
IL
S
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
SCALE: NONE
TYPICAL ROOF EDGE ANGLE SPLICE
SCALE: NONE
TYPICAL SOG JOINT PATTERN
SCALE: NONE
TYPICAL SOG CONTROL JOINT
SCALE: NONE
TYPICAL SOG CONSTRUCTION JOINT
SCALE: NONE
TYPICAL SOG CONSTRUCTION
SCALE: NONE
TYPICAL COLUMN BASE PLATE SETTING DETAILS
SCALE: NONE
TYPICAL ANCHOR ROD DETAIL
SCALE: NONE
TYPICAL ROOF OPENING AND EQUIPMENT SUPPORT
SCALE: NONE
BASE PLATE DETAIL
SCALE: NONE
TYPICAL PIPE TRENCH DETAIL
SCALE: NONE
TYPICAL COLUMN FOOTING DETAIL
SCALE: NONE
BEAM REACTION SCHEDULE
SCALE: NONE
TYPICAL FROST-FREE DOOR APRON DETAIL
ISSUED FOR DATE
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
/2
.T
A P
A U
G U
S T
1 2 3 4 5 7
A
B
C
E
F
G
W = 13.6 K
W = 14.3K
W = 21.5 K
W = 17.3 K
W
.5
K
W
.1
K W
.1 K
W
.6
K
D
12' - 0" 12' - 0" 12' - 0" 18' - 0" 5' - 0" 19' - 0"
31' - 2"
31' - 2"
/2
25' - 8 1/4"
20' - 0 1/2"
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
P R
E C
A S
T W
A L L L
O A
D
IN
G
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
1/4" = 1'-0"
PRECAST WALL IN-PLANE LOADING
1. LOADS ON THIS SHEET ARE UNFACTORED AND CALCULATED IN ACCORDANCE WITH
ASCE 7-10; I.E., DEAD, LIVE, AND SNOW LOADS ARE SERVICE LEVEL; WIND LOADS
ARE STRENGTH LEVEL.
2. IT IS THE RESPONSIBILITY OF THE PRECAST SUPPLIER'S ENGINEER TO DETERMINE
THE APPLICABLE LOAD COMBINATIONS IN ACCORDANCE WITH THE BUILDING CODE
FOR THE DESIGN OF THE PRECAST WALL PANELS AND THEIR CONNECTIONS.
3. OUT OF PLANE WIND LOAD FOR THE DESIGN OF PRECAST WALL PANELS AND THEIR
CONNECTIONS SHALL BE THE COMPONENTS AND CLADDING WIND PRESSURES
LISTED ON SHEET S 001.
4. BUILDING IS IN SEISMIC DESIGN CATEGORY A. THE SEISMIC LOADS REQUIRED BY
ASCE 7-10 SECTION 11.7 ON WALLS AND DIAPHRAGMS ARE SIGNIFICANTLY LESS
THAN THE WIND LOADS AND DO NOT GOVERN THE DESIGN. NO SEISMIC DETAILING
REQUIREMENTS NEED BE MET.
5. DESIGN OF CONNECTIONS FROM ONE PRECAST PANEL TO ANOTHER PRECAST PANEL
SHALL BE THE RESPONSIBILITY OF THE PRECAST SUPPLIER'S ENGINEER.
6. EMBEDDED PLATES AND OTHER ITEMS CAST IN TO THE PRECAST WALL PANELS FOR
CONNECTIONS TO OTHER CONSTRUCTION (SUCH AS FOUNDATIONS, ROOF
FRAMING, EDGE ANGLES, LEDGERS, ETC.) SHALL BE DESIGNED BY THE PRECAST
SUPPLIER'S ENGINEER. ANY GRAPHICAL REPRESENTATION OF THE EMBEDDED
PLATES ON THESE DRAWINGS IS SCHEMATIC ONLY AND NOT MEANT TO CONVEY THE
REQUIRED PLATE THICKNESSES OR THE QUANTITY, LAYOUT, AND SIZE OF HEADED
STUDS ON EMBEDDED PLATES.
7. DESIGN OF THE PRECAST WALL PANELS SHALL INCLUDE CONSIDERATION FOR ALL
OPENINGS WITHIN THE PRECAST WALLS. REFER TO ARCHITECTURAL, MECHANICAL,
AND ELECTRICAL DRAWINGS FOR OPENING LOCATIONS AND DIMENSIONS. IF
STRUCTURAL STEEL HEADERS OR JAMBS ARE REQUIRED WITHIN A LINE OF PRECAST
WALL PANELS TO CARRY LOADS ABOVE OR AROUND OPENINGS, OR TO SUPPORT
PRECAST WALL PANELS ABOVE OR BELOW OPENINGS, SUCH MEMBERS AND THEIR
CONNECTIONS SHALL BE DESIGNED AND PROVIDED BY THE PRECAST SUPPLIER AT
NO ADDITIONAL COST TO THE OWNER.
NOTES
LEGEND
W = XX K
DENOTES HORIZONTAL IN-PLANE WIND LOAD APPLIED TO
ENTIRE LINE OF PRECAST WALL PANELS AT THE ROOF LEVEL.
D = XX PLF
L = XX PLF
W = -XX PLF
DENOTES VERTICAL DEAD LOAD (D), LIVE LOAD (L), AND WIND
LOAD (W) APPLIED TO PRECAST WALL PANELS BY THE
CONTINUOUS LEDGER BEAM SUPPORTING ROOF JOISTS OR
THE CONTINUOUS ANGLE SUPPORTING ROOF DECK.
POSITIVE VALUES REPRESENT DOWNWARD LOAD AND
NEGATIVE VALUES REPRESENT UPLIFT. THE SELF-WEIGHT OF
THE WALL PANELS IS NOT INCLUDED IN THESE LOADS. SNOW
LOADS (INCLUDING DRIFTED SNOW) ARE INCLUDED IN THE
LIVE LOAD VALUE. WIND UPLIFT VALUES HAVE NOT BEEN
REDUCED BY ANY COUNTERACTING DEAD LOAD.
ISSUED FOR DATE
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
/2
.T
A P
A U
G U
S T
1 2 3 4 5 7
A A
B
C
E
F
G
12' - 0" 12' - 0" 12' - 0" 18' - 0" 24' - 0"
/2
/2
D
S 301
WF3.0
WF3.0
WF5.0
WF2.0
WF5.0
WF2.0
WF5.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF5.0
WF6.0
F4.0
F3.0
F4.0 F4.0
F3.0
F4.0 F4.0
F3.0
F4.0
F4.0F4.0
F4.0
F4.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF4.1 WF4.1
F5.1
WF4.1
WF2.0
WF5.0
/2
/2
/2
S 301
TYP
S 301
TYP
S 301
TYP
S 301
TYP
S 301
WF2.0
S 301
4TYP
TYP @ COLUMNS
/2
/4
/4
/2
5" 1' - 4"
8" 8" 1' - 4"1' - 11"
14' - 11" 4
3' - 6 1/4"
4' - 5 3/4" 4
" 3' - 7"
9' - 4 1/2"
27' - 1"
1' - 6" 1' - 6" 32' - 6"
14' - 11"
" 3' - 6 1/4" 4' - 5 3/4"
" 3' - 7"
1' - 6" 1' - 6" 32' - 6"
1' - 4"
8"5"
/2
/2
8"
1' - 4"
1' - 11"
/2
/2
/2
/2
/2
3' - 7 1/2" 2' - 4 1/2"
1" 1' - 11"
1" 1' - 11"
1' - 0 1/2" 24' - 0" 1' - 11"
4' - 6"
"1' - 1"
/2
S 301
SIM, TYP @ COLUMNS
1. FLOOR CONSTRUCTION, UNO: 4" SLAB ON GRADE WITH 6x6-W1.4xW1.4 WWF. SEE
TYPICAL SLAB-ON-GRADE CONSTRUCTION DETAILS FOR ADDITIONAL REQUIREMENTS.
SLAB ON GRADE SHALL BEAR ON A VAPOR BARRIER OVER MINIMUM OF 6" MDOT CLASS
21AA DENSE-GRADED AGGREGATE. CHOKE TOP OF GRAVEL WITH SAND.
2. TOP OF SLAB-ON-GRADE ELEVATION = 100'-0", UNO.
3. TOP OF FOOTING ELEVATION = 99'-0", UNO. ALL EXTERIOR FOOTINGS TO EXTEND A
MINIMUM OF 3'-6" BELOW FINISHED FLOOR OR BEAR ON EXISTING ROCK. COORDINATE
EXISTING SOIL CONDITIONS WITH GEOTECHNICAL REPORT. NOTIFY A/E IMMEDIATELY FOR
DIRECTION IF ROCK IS ENCOUNTERED LESS THAN 2'-0" BELOW FINISHED FLOOR FOR
DIRECTION. IF ROCK IS ENCOUNTERED AT A DEPTH SUCH THAT THE FOUNDATIONS WILL
BEAR ON EXISTING SOLID ROCK, CONTRACTOR TO ENGAGE GEOTECHNICAL ENGINEER
TO VERIFY EXISTING ROCK IS SUITABLE TO BEAR FOUNDATIONS. CONTRACTOR IS
RESPONSIBLE FOR PROVIDING CONCRETE ALLOWANCE FOR POTENTIAL VARYING
ELEVATION OF EXISTING ROCK SUBGRADE ACROSS SITE.
4. SEE GENERAL NOTES FOR DESIGN SOIL BEARING CAPACITY.
5. REINFORCING SHOWN ON PLAN IS IN ADDITION TO REINFORCING SHOWN IN SECTIONS,
DETAILS, AND SCHEDULES.
6. SEE ARCHITECTURAL DRAWINGS FOR INTERIOR WALL DIMENSIONS.
7. VERIFY LOCATIONS OF COLUMNS, WALLS, OPENINGS, ETC. WITH ARCHITECTURAL
DRAWINGS BEFORE PLACING FOUNDATIONS.
8. COORDINATE WITH ALL DRAWINGS FOR LOCATION OF OPENINGS, SLEEVES, AND UNDER
FLOOR PIPES, CONDUITS, DRAINS, DEPRESSIONS, ETC.
PLAN NOTES - FOUNDATION
MARK LENGTH WIDTH THICKNESS REINFORCING
F4.0
SPREAD FOOTING SCHEDULE
4' - 0" 1' - 2" (MIN.) (4) #5 EW4' - 0"
NOTES
F4.1 4' - 0" 2' - 0" (MIN.) (7) #5 EW TOP & BOT.4' - 0"
F5.1 5' - 0" 2' - 0" (MIN.) (6) #6 EW TOP & BOT.5' - 0"
F3.0 3' - 0" 1' - 2" (MIN.) (4) #5 EW3' - 0"
MARK WIDTH THICKNESS LONG. REINF.
WF2.0
WALL FOOTING SCHEDULE
SEE NOTE '3' (3) #5 2' - 0"
TRANS. REINF.
WF3.0 (3) #5 3' - 0" __
WF5.0 (5) #5 5' - 0" #5 @ 1'-0" O.C.
WF6.0 (6) #5 6' - 0" #5 @ 1'-0" O.C.
SEE NOTE '3'
SEE NOTE '3'
SEE NOTE '3'
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F O
U N
D A
T
IO
N P
L A
N
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
1/4" = 1'-0"
OVERALL FOUNDATION PLAN
KEYED NOTES - FOUNDATION
1 SUPPORTED FROST FREE ENTRY STOOP, SEE TYPICAL DETAIL FOR ADDITIONAL
INFORMATION. REFER TO CIVIL FOR EXTENTS OF ENTRY STOOP.
2 MECHANICAL FLOOR VENT, SEE MECHANICAL FOR EXACT SIZE AND LOCATIONS,
COORDINATE SLAB REQUIREMENTS AT OPENING WITH SUPPLIER.
ISSUED FOR DATE
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
/2
.T
A P
A U
G U
S T
R1
R
1 2 3 4 5 7
A A
B
C
E
F
G
S 401
S 401
S 401
12' - 0" 12' - 0" 12' - 0" 18' - 0" 5' - 0" 19' - 0" 1' - 5 1/2"
/2
/2
26' - 10"
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W x3
W16x36
W16x36
W16x36
W16x36
S 401
S 401
S 402
S 402
S 401
S 401
S 401
S 401
D
EQ
S P A
/2
W8x15
W8x15
W8x15
W8x15
W8x15
W8x15
W8x15
W8x15
W8x15
W8x15
W8x15
W10x19
W24x55W24x55
W10x19
W10x19
W8x15
W8x15
W8x15W8x15
W8x15
W8x15
W8x15
W8x15
W8x15 W8x15
W8x15
W8x15
W8x15 W8x15
W8x15W8x15
W8x15W8x15
W8x15 W8x15
W8x15W8x15
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
/2
/2
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
D A
S 401
S 401
C1B
C1B C1B
C1B
C1BC1B
C1B C1B
OUTLINE OF UPPER ROOF,
SEE S202 FOR FRAMING.
S 401
TYP
S 401
TYP
S 401
S 401
4" 8"
S 401
W8x15
1' - 4 1/2"
ERV-1
(510 LBS)
AHU-1
(250 LBS)
4"
4"
S 401
TYP
TYP
C1A C1A
C1A C1A
W x3
C1C C1C
C1CC1C
C1C
C1C C1C
C1C
W x3
1. TOP OF FRAMING ELEVATION = 111' - 0", UNO THUS (± ).
2. TOP OF FRAMING ELEVATION AT HIGH ROOF = 115' - 8", UNO THUS (± ).
PLAN NOTES - FRAMING
LEGEND
R1 INDICATES 1-1/2" 20 GA. METAL ROOF DECK, SEE GENERAL NOTES FOR
ADDITIONAL INFORMATION.
FUTURE PV ARRAY DESIGN NOTES
INDICATES MOMENT CONNECTION, SEE BEAM REACTION SCHEDULE FOR
REQUIRED DESIGN FORCES.
MARK SIZE BASE PLATE
(TxWxL)
ANCHORS EMBED
C1B
COLUMN SCHEDULE
HSS5x5x5/16 1"x0'-10"x1'-0" (4) 3/4" 1' - 0"
C1A HSS5x5x5/16 1"x1'-0"x1'-0" (4) 3/4" 1' - 0"
BASE PLATE
TYPE
B
A
C1C HSS5x5x5/16 1"x0'-10"x0'-10" (4) 3/4" 1' - 0"C
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
R O
O F
F R
A M
IN
G
P L A
N
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
1/4" = 1'-0"
OVERALL FRAMING PLAN
KEYED NOTES - FRAMING
1 MECHANICAL UNIT SUSPENDED FROM STRUCTURE. UNIT TO BE SUSPENDED DIRECTLY
FROM STEEL FRAMING, DO NOT ATTACH TO ROOF DECK. DESIGN OF HANGERS AND
CONNECTIONS BY MECHANICAL SUPPLIER, COORDINATE REQUIREMENTS WITH STEEL
FABRICATOR AS REQUIRED PRIOR TO STEEL FABRICATION.
2 BEAM TO BEAR ON PRECAST WALL BELOW, SEE DETAILS FOR ADDITIONAL
INFORMATION.
3 DECK ANGLE, REFER TO ADJACENT DETAIL FOR SIZE AND ANCHORING INFORMATION.
1. THE ROOF STRUCTURE HAS BEEN DESIGNED TO SUPPORT A LOW PROFILE
PHOTOVOLTAIC (PV) SYSTEM. THE DESIGN AND INSTALLATION OF THE SYSTEM
SHALL BE SUBJECT TO THE FOLLOWING REQUIREMENTS:
A. THE PV RACKING SUPPORT SYSTEM AND ANY ATTACHMENTS OF THE
SYSTEM TO THE ROOF SHALL BE DESIGNED BY A PROFESSIONAL ENGINEER
LICENSED IN THE STATE OF MICHIGAN AND EXPERIENCED IN THE DESIGN OF
ROOFTOP PV ARRAYS.
B. THE ENGINEER RESPONSIBLE FOR THE DESIGN SHALL DETERMINE THE WIND
LOADS IN ACCORDANCE WITH ASCE 7-16. WIND TUNNEL TEST RESULTS
MAY BE UTILIZED IN THE DESIGN, SUBJECT TO THE LIMITATIONS OF ASCE
7-16, IF THE WIND TUNNEL TEST RESULTS ARE APPLICABLE TO THIS
BUILDING AND SITE.
C. THE ENGINEER RESPONSIBLE FOR THE DESIGN SHALL DETERMINE THE
REQUIRED BALLAST AND/OR MECHANICAL ATTACHMENTS.
D. LAYOUT DRAWINGS OF THE PV SYSTEM SHALL BE SUBMITTED FOR REVIEW
AND SHALL BEAR THE SEAL OF THE ENGINEER RESPONSIBLE FOR THE
DESIGN. LAYOUT DRAWINGS SHALL INCLUDE DETAILS OF ANY REQUIRED
MECHANICAL ATTACHMENTS TO THE ROOF.
E. LAYOUT DRAWINGS SHALL BE ACCOMPANIED BY CALCULATIONS PREPARED
AND SEALED BY THE ENGINEER RESPONSIBLE FOR THE DESIGN.
F. THE TOTAL WEIGHT OF THE PV SYSTEM INCLUDING THE RACKING SYSTEM
AND ANY BALLAST, WHEN AVERAGED OVER THE GROSS AREA OF THE
SYSTEM, SHALL NOT EXCEED 12 PSF.
G. THE STRUCTURE HAS BEEN DESIGNED FOR AN ADDITIONAL 35PSF UNIFORM
SNOW LOAD TO ACCOUNT FOR DRIFTED SNOW IN THE SAWTOOTH
CONFIGURATION OF THE ANTICIPATED PV ARRAY.
H. MAXIMUM HEIGHT OF PV PANELS ABOVE THE ROOF SHALL NOT EXCEED 14
INCHES.
ISSUED FOR DATE
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
/2
.T
A P
A U
G U
S T
3 4 5
A
B
C
S 402
12' - 0" 18' - 0" 5' - 0"
S 402
D
/2
/2
1' - 0" 3' - 6" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 0" 1' - 0"
/2
/2
S 402
W16x36
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W16x36
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W x1
W16x36
S 402
3' - 2" 3' - 4"
1. TOP OF FRAMING ELEVATION = 111' - 0", UNO THUS (± ).
2. TOP OF FRAMING ELEVATION AT HIGH ROOF = 115' - 8", UNO THUS (± ).
PLAN NOTES - FRAMING
LEGEND
R1 INDICATES 1-1/2" 20 GA. METAL ROOF DECK, SEE GENERAL NOTES FOR
ADDITIONAL INFORMATION.
FUTURE PV ARRAY DESIGN NOTES
INDICATES MOMENT CONNECTION, SEE BEAM REACTION SCHEDULE FOR
REQUIRED DESIGN FORCES.
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
U P
P E
R R
O O
F F
R A
M
IN
G P
L A
N
-1
.0
S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
1/4" =…