12 751.21042.TAP_Milliken Nature Center at Park Arch_CD Drawings - 08 Mechanical.pdf
PDF 3 MB Posted
- Solicitation number
- RFQ - 171 - 220000000529
- Issued by
- Mackinac County, Mackinac Island City, Michigan
About this file
This document appears to be a set of plans and specifications related to a state and local contract opportunity for the Milliken Nature Center at Arch Rock in Mackinac Island, Michigan. The project involves mechanical and plumbing work, including an HVAC system with a heat pump and energy recovery ventilator, plumbing fixtures and piping, a greywater reuse system, and site utility work. The bid attachments must be uploaded to the SIGMA VSS system, and questions should be emailed to the project contact. COVID-19 precautions may be required, such as wearing masks.
The contract opportunity includes pricing for various mechanical and plumbing equipment and systems, including pumps, fans, grilles, and ductwork. Funding sources are not specified, but the project appears to be state-funded. The project timeline is not explicitly stated, but the bid attachments suggest the construction phase is imminent.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BRITISH THERMAL UNIT PER HOUR
AUTOMATIC CONTROL DAMPER
BRITISH THERMAL UNIT PER HOUR
CALIBRATED BALANCING VALVE
CUBIC FEET PER MINUTE
ENTERING AIR TEMPERATURE
EXTERNAL STATIC PRESSURE
ELECTRIC WATER COOLER
ENTERING WATER TEMPERATURE
LEAVING AIR TEMPERATURE
LEAVING WATER TEMPERATURE
MIXED AIR TEMPERATURE
FIELD INSTALLEDF.I.
MBH
M.B.
(THOUSANDS)
MOP BASIN
L.A.T.
L.W.B
L.W.T.
M.A.
M.A.T.
MAX.
LAV.
L.D.B.
LOUV.
G.P.M.
H.B.
HP
I.E.
F.M.
F.P.M.
F.R.
LAVATORY
LEAVING DRY BULB
LEAVING WET BULB
MIXED AIR
MAXIMUM
LOUVER
FLOOR MOUNTED
FEET PER MINUTE
FIN RADIATION
GALLONS PER MINUTE
HOSE BIBB
HORSE POWER
INVERT ELEVATION
CONTROL VALVEC.V.
F.C.
F.D.
(FD)
F.H.C.
E.W.B.
E.W.C.
E.W.T.
EXIST.
E.A.
E.A.T.
E.D.B.
E.F.
E.S.P.
D.F.
D.S.
DN.
ENTERING WET BULB
FLEXIBLE CONNECTION
FLOOR DRAIN
FIRE DAMPER
FIRE HOSE CABINET
EXISTING
DRINKING FOUNTAIN
DOWN SPOUT
EXHAUST AIR
ENTERING DRY BULB
EXHAUST FAN
DOWN
C.B.
C.H.
C.I.
C.M.
C.O.
C.B.V.
C.F.H.
C.F.M.
B.D.D.
B.F.
BTUH
B.V.
B.D.
A.F.F.
A.G.
A.P.D.
CATCH BASIN
CUBIC FEET PER HOUR
CABINET HEATER
CAST IRON
CEILING MOUNTED
CLEAN OUT
BALANCING DAMPER
ABOVE FINISHED FLOOR
ABOVE GRADE
AIR PRESSURE DROP
BACKDRAFT DAMPER
BARRIER FREE
BALANCING VALVE
A.C.D.
TEMPERATURE RISET.R.
TOTAL STATIC PRESSURE
TERMINAL UNIT BOX
TEPID WATER CONNECTION
VIBRATION ISOLATORS
WATER PRESSURE DROP
W.SK. WASH SINK
V.
T.S.
T.S.P.
T.U.
T.W.C.
U.H.
URN.
VEL.
V.I.
V.I.F.
V.S.
V.T.R.
W.
W.C.
W.M.
W.P.D.
VELOCITY
VERIFY IN FIELD
VENT STACK
VENT THRU ROOF
WASTE
WATER CLOSET
WALL MOUNTED
TIP SPEED
UNIT HEATER
URINAL
VENT
MANUFACTURER(S)MFR.(S)
BACKFLOW PREVENTER
MANUAL AIR VENT
NORMALLY CLOSED
NON-FREEZE WALL HYDRANT
NOT IN CONTRACT
OUTSIDE AIR INTAKE
POST INDICATOR VALVE
PRESSURE REDUCING VALVE
PRESSURE / TEMPERATURE TAPPING
RELATIVE HUMIDITY
REVOLUTIONS PER MINUTE
REDUCED PRESSURE PRINCIPAL
STATIC PRESSURE
RETURN AIRR.A.
S.O.V.
R.D.
R.H.
R.I.O.
R.P.M.
RPPBP
R.V.
S.A.
SENS.
SHR.
SK.
S.P.
S.SK.
TEMP.
TOT.
SHUT-OFF VALVE
SENSIBLE
SHOWER
SERVICE SINK
TEMPERATURE
TOTAL
SINK
ROOF DRAIN
ROUGH IN ONLY
RELIEF VALVE
SUPPLY AIR
M.H.
MIN.
MTG.
M.V.
N.C.
N.F.W.H.
N.I.C.
N.O.
O.A.
O.A.I.
OCT.
P.A.
P.D.
P.I.V
P.R.V.
P.T.
OUTSIDE AIR
OCTAVE
PIPE ANCHOR
PRESSURE DROP
MANHOLE
MINIMUM
MOUNTING
NORMALLY OPEN
TEPID WATER
TEPID WATER RETURNTWR
TW
HUMIDISTAT
PRESSURE GAUGE
OXYGEN
REDUCED PRESSURE PRINCIPLE BACKFLOW
PUMPED CONDENSATE
PRIMARY HEATING HOT WATER SUPPLY
PRIMARY HEATING HOT WATER RETURN
PRESSURE / TEMPERATURE TAPPING
PRESSURE RELIEF VALVE
PRESSURE REDUCING VALVE
OUTSIDE STEM AND YOKE VALVE
SMOKE DAMPER
SHUT-OFF VALVE
STEAM
SOFT HOT WATER
SPRING CHECK VALVE
SOFT HOT WATER RETURN
SOFT COLD WATER
SANITARY SEWER (BELOW FLOOR)
SANITARY SEWER (ABOVE FLOOR)
PREVENTER
O2
PHR
PC
PHS
SAN
SAN
SHW
SHWR
S
STM (#)
SCW
THERMOMETER
STRAINER
THROTTLING VALVE
THERMOSTAT
TRIPLE DUTY VALVE (STRAIGHT)
TRIPLE DUTY VALVE (ANGLE)
THREE-WAY CONTROL VALVE
STORM (BELOW FLOOR)
STORM SEWER (ABOVE FLOOR)
VENT
VACUUM BREAKER
VACUUM
UNION
ST
ST
VAC
V
STEAM TRAPT
AW
CAP
AWV
CR
CWR
CWS
CS
A
CD
COND
CTR
CTS
FP
FS
FD
GAS
FOR
FOS
HR
G
HS
HPR
HPS
CONTROL VALVE
HOT WATER SUPPLY (DOMESTIC)
HOT WATER RETURN (DOMESTIC)
HEAT PUMP SUPPLY
HEAT PUMP RETURN
HEATING HOT WATER SUPPLY
HEATING HOT WATER RETURN
GAS COCK
FUEL OIL SUPPLY
FUEL OIL RETURN
FOOTING DRAIN
FLOW SWITCH
FLOW METER (WAFER TYPE)
FLOW METER (PROBE TYPE)
FIRE PROTECTION
FIRE/SMOKE DAMPER
FIRE DAMPER (VERTICAL)
FIRE DAMPER (HORIZONTAL)
COOLING TOWER SUPPLY
COOLING TOWER RETURN
CONDENSATE DRAIN
CONDENSATE
COLD WATER (DOMESTIC)
CHILLED WATER SUPPLY
CHILLED WATER RETURN
CHECK VALVE
CALIBRATED BALANCING VALVE
BUTTERFLY VALVE
BALANCING VALVE
ACID WASTE VENT
ACID WASTE
COMPRESSED AIR
CHILLER RETURN
CHILLER SUPPLY
TEMPERATURE SENSOR
STORM SEWER (OVERFLOW SYSTEM)ST (OF)
MVAC MEDICAL VACUUM
MEDICAL AIRMA
S
S
T
H
TS
HUMIDITY SENSOR
THREE-WAY CONTROL VALVE
CONTROL VALVE
FLOW METER (PROBE TYPE)
TEMPERATURE SENSORTS
CARBON DIOXIDE SENSOR
DIFFERENTIAL PRESSURE SENSOR
AS
HS
CO2
DP
AIRFLOW SENSOR
F FREEZE STAT
MOTORIZED ACTUATORM
ES ENTHALPY SENSOR (TEMP / HUMIDITY)
MS MOISTURE SENSOR
DS DUCT SMOKE SENSOR
DOMESTIC WATER
NATURAL GAS
COMPRESSED AIR
MEDICAL GASES
VACUUM
STEAM / CONDENSATE
BRANCH CONNECTION OFF TOP BRANCH CONNECTION OFF BOTTOM
APPLIES TO THE FOLLOWING SYSTEMS: APPLIES TO THE FOLLOWING SYSTEMS:
NOTE: BOTTOM AS INDICATED OR SIDE
CONNECTION IS ACCEPTABLE.
CONNECTION TO THE TOP OF THE MAINS
IS NOT ACCEPTABLE.
HEATING HOT WATER
CHILLED WATER
GEOTHERMAL
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
M E
C H
A N
IC
A
L
P L U
M B
IN
G
S Y
M B
O L S
A
B B
R E
V
IA
T
IO
N S
A
N D
G E
N E
R A
L N
O T
E S
-1
.0
M P
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
GENERAL MECHANICAL NOTESMECHANICAL SYMBOLSABBREVIATIONS
CONTROL SYMBOLS
1 DETAILS SHOWN ILLUSTRATE DESIGN INTENT, NOT ALL POSSIBLE
CONDITIONS. DRAWINGS ARE NOT TO BE CONSIDERED FABRICATION
DRAWINGS.
2 IF THE CONTRACTOR ELECTS TO PROVIDE EQUIPMENT OTHER THAN
BASIS OF DESIGN, THE CONTRACTOR SHALL BE RESPONSIBLE TO
COORDINATE THE LAYOUT AND CLEARANCE REQUIREMENTS IN ALL
SPACES CONTAINING EQUIPMENT AND PROVIDE EQUIPMENT MEETING
THE SPECIFICATIONS AND ACHIEVING CODE REQUIRED CLEARANCES
WITHIN THE SPACE PROVIDED.
3 COORDINATE ALL NEW CONSTRUCTION WORK OR ACTIVITY WITH THAT
WHICH IS REQUIRED BY OTHER TRADES OR INSTALLERS IN ORDER TO
PROVIDE A COMPLETE SYSTEM INCLUDING ALL NECESSARY
COMPONENTS, FITTINGS, AND OFFSETS.
4 INSTALLER SHALL VERIFY ALL EXISTING JOBSITE CONDITIONS AND
DIMENSIONS AND BE RESPONSIBLE FOR THE SAME. NOTIFY THE
ENGINEER OF DISCREPANCIES PRIOR TO COMMENCING WORK.
5 FIRE SEAL ALL PENETRATIONS, SUCH AS PIPES, DUCTS, CONDUIT, ETC.
THROUGH FIRE AND/OR SMOKE RATED ASSEMBLIES.
6 MECHANICAL INSTALLER IS RESPONSIBLE FOR PATCHING OF WALLS,
CEILINGS, AND FLOORS WHERE FIXTURES, MECHANICAL EQUIPMENT,
SHEET METAL, OR PIPING HAS BEEN REMOVED, RELOCATED, OR
INSTALLED.
7 ALL PIPING SHALL AVOID LOCATIONS DIRECTLY ABOVE ALL ELECTRICAL
EQUIPMENT. COORDINATE WITH ELECTRICAL.
8 ALL LOW VOLTAGE CABLING SHALL BE RUN IN CONDUIT BETWEEN
DEVICE AND CABLE TRAY OR TECHNOLOGY RACK. NO CABLING SHALL
BE VISIBLE IN EXPOSED CEILING SPACES. EXPOSED CONDUIT SHALL
BE PAINTED TO MATCH SURFACE IT IS SUPPORTED FROM. WIRING
ROUTED IN ACCESSIBLE CEILING SPACES SHALL BE INDEPENDENTLY
SUPPORTED WITH COMM HOOKS OR RINGS.
9 COORDINATE ALL TEMPERATURE SENSOR LOCATIONS WITH
"ELECTRICAL DEVICES ALIGNMENT GUIDELINES" DETAIL ON SHEET
E001.
SCALE: NONE
BRANCH TAKE-OFF PIPING DETAIL
ISSUED FOR DATE
W
W
W
W
T R
E E
C
LE
A R
IN
G
LIM
IT
TR
EE
C
LE
AR
IN
G L
IM
IT
1 2 3 4 5 7
A
B
C
E
F
G
D
EXIST. CO
RESTROOMS
NATURE CENTER
SEPTIC SYSTEM
PER CIVIL
ARCH ROCK ROAD
ARC
H
RO
C
K BIC
YC
LE TRAIL
CARRIAGE
STAGING AREA
SEPTIC FIELD
4" SAN TO CIVIL
I.E. 96' (704')
BIKE RACKS
BIKE RACKS
BIKE RACKS
ARCH ROCK
PLAZA
EXIST. HORSE
WATERING YARD
HYDRANT
SEPTIC TANK
TRANSFORMER
ELEC
2" CW
I.E. 95' (703')
FIELD VERIFY
HP-1
HP-2
3" ST TO CIVIL
I.E. 98' (706')
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
GT-1
REFRIG
3" ST TO CIVIL
I.E. 99.3' (707.3')
3" ST TO CIVIL
I.E. 99.3' (707.3')
3" ST TO CIVIL
I.E. 99.3' (707.3')
3" ST TO CIVIL
I.E. 99.3' (707.3')
DF-1
BF
3" ST TO CIVIL
I.E. 98' (706')
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
M E
C H
A N
IC
A
L S
IT
E
P L A
N
-1
.0
M S
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
1/8" = 1'-0"
MECHANICAL SITE PLAN
KEYED NOTES - MECHANICAL SITE
1 CONNECT TO EXIST. 2" DOMESTIC COLD WATER. VERIFY LOCATION IN
FIELD.
2 REPLACE EXIST. HORSE WATERING HOSE BIBB AND PIPING. CONNECT
TO NEW WATER MAIN.
3 REMOVE EXIST. DOMESTIC WATER SERVICE PIPING TO EXIST.
BUILDING.
4 REMOVE EXIST. CLEANOUT AND ASSOCIATED PIPING. PREPARE AREA
FOR NEW WORK.
5 CONNECT TO DOWNSPOUT PER ARCH BELOW GRADE. REFER TO DETAIL
ON P501. ROUTE TO STORMWATER MAIN PER CIVIL.
6 OUTDOOR HEAT PUMP LOCATED ON 4" CONCRETE PAD. ROUTE
REFRIGERANT PIPNG BELOW GRADE.
FF = 100'-0" (708')
1 2 3 4 5
A
B
C
D
E
F
G
6 8
2" CW UP
2" CW
S A N
CO
4" SAN UP
TO HEADER
4" SAN
1/2" CW
4" SAN
3" SAN
S A N
UP TO DF-1
4" SAN
GT-1
SUMP TANK LOCATED
BELOW GRADE. ROUTE
SANITARY FROM LAVS
TO GT-1
3" SAN
N P W
2" NPW UP TO
FILTRATION SKID
3" ST
I.E. 98' (706')
3" ST UP TO
DOWNSPOUT
3" ST
I.E. 98' (706')
3" ST
I.E. 99.3' (707.3')
3" ST
I.E. 99.3' (707.3')
3" ST
I.E. 99.3' (707.3')
3" ST
I.E. 99.3' (707.3')
(FROM LAVS)
4" SAN
4" SAN UP
TO HEADER
S A N
4" SAN
4" SAN
I.E. 96' (704')
S A N
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
3" ST UP TO
DOWNSPOUT
CO
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F O
U N
D A
T
IO
N P
L U
M B
IN
G
P L A
N
-1
.0
P
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
KEYED NOTES - PLUMBING
1 1/2" CW, 1/2" HW, 1/2" HWR, 1-1/2" SAN, 1-1/4" V TO LAVATORY.
2 3/4" HW, 3/4" CW, 3" SAN, 1-1/2" V TO MOP BASIN.
3 1" CW, 4" SAN, 2" V TO WATER CLOSET. ROUTE PIPING WITHIN
SUPPORT SPACE TO PROVIDE ACCESS.
4 3/4" CW, 2" SAN, 1-1/2" V TO URINAL. ROUTE PIPING WITHIN SUPPORT
SPACE TO PROVIDE ACCESS.
5 ROUTE 1/2" CW AND 1-1/4" SAN BELOW GRADE TO FREEZE RESISTANT
DRINKING FOUNTAIN.
6 3/4" CW TO HOSE BIBB. PROVIDE SHUTOFF VALVE. REFER TO DETAILS
ON P501.
7 CONNECT TO EXIST. DOMESTIC WATER SERVICE BELOW GRADE. VERIFY
LOCATION IN FIELD. COORDINATE WITH CIVIL.
8 MOUNT WATER HEATER ABOVE MOP BASIN. REFER TO DETAIL ON
P501.
9 REMOVE EXIST. CLEANOUT AND ASSOCIATED PIPING. VERIFY LOCATION
IN FIELD. PREPARE AREA FOR NEW WORK.
10 1/2" CW DN. ROUTE PIPING BELOW GRADE TO DRINKING FOUNTAIN.
11 ROUTE FULL SIZE HEADERS ALONG WALL AND DISTRIBUTE TO
FIXTURES.
12 SAN UP TO FLOOR DRAIN.
13 SAN UP TO LAVATORY.
14 SAN UP TO WATER CLOSET.
15 GREYWATER REUSE FILTRATION SKID BASED ON HIGHLAND TANK
"HIGH-DRO CLEAR". REFER TO SCHEMATIC ON SHEET P501.
16 GRAVITY FED SANITARY FROM BUILDING TO SEPTIC SYSTEM PER CIVIL.
17 GREYWATER REUSE COLLECTION TANK. REFER TO DETAIL ON P501.
18 LOCATE SHUTOFF VALVES WITHIN ACCESS PANEL BEHIND KNEEBOARD.
DO NOT LOCATE VALVES ABOVE FAMILY RESTROOM CEILING.
1/4" = 1'-0"
FOUNDATION PLUMBING PLAN
B
C
D
E
F
G
6 8
WH-1
WC-1
BF
WC-1
BF
WC-1 WC-1 WC-1 WC-1
WC-1 WC-1
UR-1
WC-1
BF
LAV-2
BF
UR-1
MB-1
LAV-1
BF
LAV-1
BF
LAV-1
BF
LAV-1
BF
1 1
1 1
3 3 3 3
3 3
4 4
DF-1
BF
NFWH-1
18" AG
2" CW DN
EXIST. CO
FD-2
FD-1
FD-1
FD-1
C W
/2
H W
/2
C W
3" VTR
/2 V
CP-1
NATURE
CENTER
MEN
SUPPORT
WOMEN
FAMILY TOILET
VENDING
STORAGE
GREYWATER
FILTRATION SKID 1
/2
H W
R
3/4" HWR
1 1/4" HW
2" CW
2" NPW DN TO
FLUSH VALVES
1" CW
CO
FD-1
CO
V
C W
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F
IR
S T
F L O
O R
P L U
M B
IN
G
P L A
N
-1
.0
P
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
KEYED NOTES - PLUMBING
1 1/2" CW, 1/2" HW, 1/2" HWR, 1-1/2" SAN, 1-1/4" V TO LAVATORY.
2 3/4" HW, 3/4" CW, 3" SAN, 1-1/2" V TO MOP BASIN.
3 1" CW, 4" SAN, 2" V TO WATER CLOSET. ROUTE PIPING WITHIN
SUPPORT SPACE TO PROVIDE ACCESS.
4 3/4" CW, 2" SAN, 1-1/2" V TO URINAL. ROUTE PIPING WITHIN SUPPORT
SPACE TO PROVIDE ACCESS.
5 ROUTE 1/2" CW AND 1-1/4" SAN BELOW GRADE TO FREEZE RESISTANT
DRINKING FOUNTAIN.
6 3/4" CW TO HOSE BIBB. PROVIDE SHUTOFF VALVE. REFER TO DETAILS
ON P501.
7 CONNECT TO EXIST. DOMESTIC WATER SERVICE BELOW GRADE. VERIFY
LOCATION IN FIELD. COORDINATE WITH CIVIL.
8 MOUNT WATER HEATER ABOVE MOP BASIN. REFER TO DETAIL ON
P501.
9 REMOVE EXIST. CLEANOUT AND ASSOCIATED PIPING. VERIFY LOCATION
IN FIELD. PREPARE AREA FOR NEW WORK.
10 1/2" CW DN. ROUTE PIPING BELOW GRADE TO DRINKING FOUNTAIN.
11 ROUTE FULL SIZE HEADERS ALONG WALL AND DISTRIBUTE TO
FIXTURES.
12 SAN UP TO FLOOR DRAIN.
13 SAN UP TO LAVATORY.
14 SAN UP TO WATER CLOSET.
15 GREYWATER REUSE FILTRATION SKID BASED ON HIGHLAND TANK
"HIGH-DRO CLEAR". REFER TO SCHEMATIC ON SHEET P501.
16 GRAVITY FED SANITARY FROM BUILDING TO SEPTIC SYSTEM PER CIVIL.
17 GREYWATER REUSE COLLECTION TANK. REFER TO DETAIL ON P501.
18 LOCATE SHUTOFF VALVES WITHIN ACCESS PANEL BEHIND KNEEBOARD.
DO NOT LOCATE VALVES ABOVE FAMILY RESTROOM CEILING.
1/4" = 1'-0"
FIRST FLOOR PLUMBING PLAN
B
C
D
E
F
G
6 8
3" VTR
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
P L U
M B
IN
G
R O
O F
P L A
N
-1
.0
P
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
KEYED NOTES - PLUMBING
1 1/2" CW, 1/2" HW, 1/2" HWR, 1-1/2" SAN, 1-1/4" V TO LAVATORY.
2 3/4" HW, 3/4" CW, 3" SAN, 1-1/2" V TO MOP BASIN.
3 1" CW, 4" SAN, 2" V TO WATER CLOSET. ROUTE PIPING WITHIN
SUPPORT SPACE TO PROVIDE ACCESS.
4 3/4" CW, 2" SAN, 1-1/2" V TO URINAL. ROUTE PIPING WITHIN SUPPORT
SPACE TO PROVIDE ACCESS.
5 ROUTE 1/2" CW AND 1-1/4" SAN BELOW GRADE TO FREEZE RESISTANT
DRINKING FOUNTAIN.
6 3/4" CW TO HOSE BIBB. PROVIDE SHUTOFF VALVE. REFER TO DETAILS
ON P501.
7 CONNECT TO EXIST. DOMESTIC WATER SERVICE BELOW GRADE. VERIFY
LOCATION IN FIELD. COORDINATE WITH CIVIL.
8 MOUNT WATER HEATER ABOVE MOP BASIN. REFER TO DETAIL ON
P501.
9 REMOVE EXIST. CLEANOUT AND ASSOCIATED PIPING. VERIFY LOCATION
IN FIELD. PREPARE AREA FOR NEW WORK.
10 1/2" CW DN. ROUTE PIPING BELOW GRADE TO DRINKING FOUNTAIN.
11 ROUTE FULL SIZE HEADERS ALONG WALL AND DISTRIBUTE TO
FIXTURES.
12 SAN UP TO FLOOR DRAIN.
13 SAN UP TO LAVATORY.
14 SAN UP TO WATER CLOSET.
15 GREYWATER REUSE FILTRATION SKID BASED ON HIGHLAND TANK
"HIGH-DRO CLEAR". REFER TO SCHEMATIC ON SHEET P501.
16 GRAVITY FED SANITARY FROM BUILDING TO SEPTIC SYSTEM PER CIVIL.
17 GREYWATER REUSE COLLECTION TANK. REFER TO DETAIL ON P501.
18 LOCATE SHUTOFF VALVES WITHIN ACCESS PANEL BEHIND KNEEBOARD.
DO NOT LOCATE VALVES ABOVE FAMILY RESTROOM CEILING.
1/4" = 1'-0"
PLUMBING ROOF PLAN
1 1/2" CW, 1/2" HW, 1/2" HWR, 1-1/2" SAN, 1-1/4" V TO LAVATORY.
2 3/4" HW, 3/4" CW, 3" SAN, 1-1/2" V TO MOP BASIN.
3 1" CW, 4" SAN, 2" V TO WATER CLOSET. ROUTE PIPING WITHIN
SUPPORT SPACE TO PROVIDE ACCESS.
4 3/4" CW, 2" SAN, 1-1/2" V TO URINAL. ROUTE PIPING WITHIN SUPPORT
SPACE TO PROVIDE ACCESS.
5 ROUTE 1/2" CW AND 1-1/4" SAN BELOW GRADE TO FREEZE RESISTANT
DRINKING FOUNTAIN.
6 3/4" CW TO HOSE BIBB. PROVIDE SHUTOFF VALVE. REFER TO DETAILS
ON P501.
7 CONNECT TO EXIST. DOMESTIC WATER SERVICE BELOW GRADE. VERIFY
LOCATION IN FIELD. COORDINATE WITH CIVIL.
8 MOUNT WATER HEATER ABOVE MOP BASIN. REFER TO DETAIL ON
P501.
9 REMOVE EXIST. CLEANOUT AND ASSOCIATED PIPING. VERIFY LOCATION
IN FIELD. PREPARE AREA FOR NEW WORK.
10 1/2" CW DN. ROUTE PIPING BELOW GRADE TO DRINKING FOUNTAIN.
11 ROUTE FULL SIZE HEADERS ALONG WALL AND DISTRIBUTE TO
FIXTURES.
12 SAN UP TO FLOOR DRAIN.
13 SAN UP TO LAVATORY.
14 SAN UP TO WATER CLOSET.
15 GREYWATER REUSE FILTRATION SKID BASED ON HIGHLAND TANK
"HIGH-DRO CLEAR". REFER TO SCHEMATIC ON SHEET P501.
16 GRAVITY FED SANITARY FROM BUILDING TO SEPTIC SYSTEM PER CIVIL.
17 GREYWATER REUSE COLLECTION TANK. REFER TO DETAIL ON P501.
18 LOCATE SHUTOFF VALVES WITHIN ACCESS PANEL BEHIND KNEEBOARD.
DO NOT LOCATE VALVES ABOVE FAMILY RESTROOM CEILING.
WH-1
WH-1
BASED ON "LOCHINVAR" OR EQUAL
MODEL ESP-030-K-2, 240 VOLT, 4500 W.
30 GALLON NOMINAL STORAGE CAPACITY.
THERMOMETER
1-1/4" CW
1-1/4" HW
CV
VACUUM
RELIEF
VALVE
UNIT MFG. SUPPLIED WALL BRACKETS, UNIT
MFG. SUPPLIED WALL BRACKETS MOUNT
WATER HTR. AS HIGH AS POSSIBLE
2" HIGH POLYSTYRENE WATER HEATER DRAIN
PAN w/ 3/4" DRAIN OUTLET. PIPE TO 6"
ABOVE MOP BASIN
THREADED HOSE DRAIN CONNECTION
THERMAL EXPANSION ABSORBER.
BASED ON "AMTROL" ST-* OR EQUAL
COPPER UNIONS (TYP.)
SHUT-OFF VALVE (TYP.)
TEMPERATURE & PRESSURE
RELIEF VALVE PIPING TO M.B.
TERMINATE PIPING 4" ABOVE TOP
EDGE OF M.B. PROVIDING AN AIR GAP
C.B.V.
CP-1
A
AQUASTAT
3/4" HWR
RPPBFP
2" CW
FLOOR
2" DOMESTIC WATER
SERVICE. CONNECT TO
EXIST. METER LOCATED AT
ARCH ROCK ROAD.
COORDINATE WITH CIVIL.
DRAIN
AIR GAP
FITTING
WATER SERVICE SCHEDULE
SERVICE
DOMESTIC
SITE
MAX FLOW RATE MAX PRESSURE DROP
50 GPM
10 GPM
8 PSI
8 PSI
GRADE
EXTERIOR WALL
2" BLIND FLANGE
SHUT-OFF
VALVE
1" SITE CW
DRAIN VALVE WITH
HOSE BIBB
COMPRESSED AIR QUICK
DISCONNECT WITH SHUTOFF
VALVE FOR WINTERIZATION
WYE BRANCH
45° BEND
6" GRAVEL
PRECAST CONCRETE
GRADE RING
SET CASTING IN MORTAR
FINISHED GRADE
THREADED PLUGCASTING
EJIW 1040
OPERATION LEVEL
HOLE FOR PADLOCK
3/4" CONTRACTION
THREAD FOR HOSE
VALVE BODY
VALVE RUBBER
GRAVEL
1" CW
BRICK OR SIMILAR
(NOT PROVIDED)
DRAINAGE HOLE
BACK FLOW VALVE
ELBOW WITH
OUTSIDE THREAD
BROAD LINE
GROUND
FROST FREE HYDRANT
BY PLUMBING CONTRACTOR
MODULAR MECHANICAL
SEAL
SERVICE
PIPE
STEEL SLEEVE WITH
WELDED WATER STOP
COLLAR
CONCRETE WALL/FLOOR
STAINLESS STEEL
BOLT/NUT
PRESSURE PLATES
PRESSURE PLATES
EXTERIOR GRADE FOAM
SEALANT
1/4" THICK STEEL WATERSTOP
AND ANCHOR COLLAR WELDED
TO SCHED. 40 SLEEVE. ID TO
MATCH PIPE SLEEVE OD AND
OD TO BE 4" LARGER THAN ID
WASTE
VENT
FINISHED WALL
XX" HWR PIPE WITH
INSULATION EXTENDING
FROM LAST HW
CONNECTION (WHERE
APPLICABLE)
XX" HW PIPE WITH
INSULATION ROUTED IN
WALL OR CHASE
XX" CW PIPE WITH
INSULATION ROUTED IN
WALL OR CHASE
SANITARY WYE FITTING
LAVATORY
½" CW & HW BRANCH PIPING
THRU WALL TO LAVATORY
ASSE 1070
MIXING VALVE
FIXTURE STOP
5"
MIN.
FINISHED FLOOR
OFFSET TRAP
ON B.F. UNITS
TILE WHERE APPLICABLE
SLOPE TO DRAIN
(REFER TO NOTES BELOW)
INSTALL FLOOR DRAIN 1/2"
BELOW FINISHED FLOOR.
CONCRETE TRADE SHALL
FINISH THE TOP OF FLOOR
FLUSH WITH DRAIN.
NOTES
1. FOR FLOOR DRAINS WITH SQUARE TOPS.
A. WHERE TILE HAS A DIMENSION LARGER THAN 2", MOUNT THE FLOOR
DRAIN FLUSH WITH THE FINISHED FLOOR. DO NOT SLOPE THE FLOOR
TO THE DRAIN.
B. ALIGN FLOOR DRAIN TOPS WITH TILE FLOORS.
2. WHERE EDGE OF FLOOR DRAIN IS WITHIN 24" OF WALL, ADJUST SLOPE TO
SUIT INSTALLATION.
CAST IRON DRAIN BODY
WITH PUSH ON GASKET
OUTSIDE
INSIDE
SEALS SHALL BE MODULAR
MECHANICAL TYPE CONSISTING
OF INTERLOCKING SYNTHETIC
RUBBER LINKS SHAPED TO
CONTINUOUSLY FILL THE
ANNULAR SPACE BETWEEN
THE PIPE AND WALL OPENING
AN ABSOLUTE WATERTIGHT
SEAL BETWEEN THE PIPE AND
THE WALL OPENING IS REQ'D
CARRIER LINE
WALL PENETRATION
SEAL
WALL SLEEVE
WATER STOP AND
ANCHOR COLLAR
WALL
FINISHED WALL SURFACE
STANDARD WEIGHT STEEL
PIPE SLEEVE OF SIZE TO
PASS PIPE AND INSULATION
FINISHED ESCUTCHEON PLATE
FLUSH AGAINST WALL AND
OF SIZE TO COMPLETELY
COVER OPENING
CONCEALED PIPING
PIPE AND INSULATION TO BE
CENTERED IN SLEEVE - DO NOT
SUPPORT PIPE FROM SLEEVE
TERMINATE SLEEVE FLUSH WITH
FINISHED WALL SURFACES
SEAL AND CAULK ALL SLEEVES,
THRU FIRE WALL WITH FIRE
STOPPING SEALANTS
PIPING EXPOSED TO VIEW
CARPET CLIP
UNFINISHED OR
CARPETED FLOOR
FINISHED SLAB
NICKEL BRONZE TOP
SET SCREW
FINISHED FLOOR
FINISHED SLAB
CAST IRON CLEANOUT
BODY WITH PUSH-ON
GASKET
ADJUSTABLE TOP
HOUSING
GASKETED CONNECTION
PVC CLEANOUT PIPE
BRONZE CLEANOUT
PLUG WITH GASKETED
SEAL
GRADE
GREYWATER FILTRATION SYSTEM WITHIN SUPPORT ROOM
CONTROL PANEL
240V/1P
N.C.
CF-1
CARTRIDGE
FILTER
3"
UV-1
ULTRAVIOLET LIGHT
N.C.
FILTRATION SKID
84"x36" ALUMINUM DECK WITH ALUMINUM
OR STAINLESS STEEL SUPPORTS. PROVIDE
36" CLEARANCE AT FRONT & SIDES.
GREYWATER
SUMP TANK
(GT-1)
250 GAL
3" NPW
FROM LAVATORY
SANITARY
N.C.
3" NPW
VFD
WATER QUALITY SENSOR &
TAP FOR REMOTE TESTING
GP-1 SUBMERSIBLE EFFLUENT PUMP
BASED ON "GRUNDFOS" MODEL SBA3-35.
15 GPM @ 20 FT HD, 120/1/60.
PROVIDE MANUFACTURER CONTROLS IN
COORDINATION WITH FILTRATION SKID
CONTROL PANEL.
ACCESS HATCH
GP-1
GP-1
MF-1
MULIT-MEDIA
FILTER
3"
TO FLUSH VALVES3" NPW
TO CONTROL PANEL
FLOW METERS TIED INTO
BMS TO MONITOR
CONSUMPTION
PRESSURE GAUGE
3" DOMESTIC
WATER MAKEUP
WATER TREATMENT
CHAMBER
GP-2
GREYWATER BOOSTER PUMP
BASED ON "GRUNDFOS"
15 GPM @ 20 FT HD
120/1/60
GREYWATER SYSTEM BASED ON
"HIGHLAND TANK HIGHDRO CLEAR"
GREYWATER TREATMENT SYSTEM.
GRADE
DOWNSPOUT
PER ARCH
3" SAN CONNECTION
BELOW GRADE TO
DOWNSPOUT
3" SANSAN TO MAIN
PER CIVIL
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
P L U
M B
IN
G
S C
H E
D U
L E
S A
N D
D E
T A
IL
S
-1
.0
P
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
SCALE: NONE
SHELF MOUNTED ELECTRIC WATER HEATER DETAIL (WH-1)
SCALE: NONE
WATER SERVICE DETAIL
SCALE: NONE
FROST CLEANOUT DETAIL
SCALE: NONE
FROST FREE YARD HYDRANT DETAIL
SCALE: NONE
WATERTIGHT PIPE PENETRATION DETAIL
SCALE: NONE
TYPICAL LAVATORY DETAIL
SCALE: NONE
FINISH FLOOR DRAIN DETAIL
SCALE: NONE
PIPING SLEEVE DETAIL - HORIZONTAL UNDERGROUND SCALE: NONE
PIPING SLEEVE DETAIL - INTERIOR WALL
SCALE: NONE
FLOOR CLEANOUT DETAIL
SCALE: NONE
GREYWATER REUSE SCHEMATIC
SCALE: NONE
DOWNSPOUT CONNECTION DETAIL
M
T S
T S
M
M 301
1 2 3 4 5
A
B
C
D
E
F
G
6 8
M 301
1 AHU-1
36"x14"
900 CFM EA
M 301
WOMEN
SUPPORT
FAMILY TOILET
MEN
NATURE
CENTER
VENDING
AHU-2
M 301
ERV-1
SA-1
50 CFM
TO HP-1
EXHAUST LOUVER
30"x8"
300 CFM
16"x10"
EA-1
100 CFM
"x
900 CFM
OA INTAKE
RETURN LOUVER
34"x8"
900 CFM
DUCTED RETURN
PLENUM
6"ø
18"x6"ø
TR-1
300 CFM
TYP OF 3
12"x4"ø
12"x4"ø
12"x4"ø
"x "ø
18"x6"Ø SA DN TO
BELOW GRADE
"x
300 CFM
OA INTAKE
REFRIG
ROUTE REFRIG PIPING
BELOW GRADE
EXHAUST INTAKE
LOUVER
EF-1
HDPE DUCTWORK IN
NATURE CENTER
ROUTED BELOW GRADE
"x
"ø
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
F
IR
S T
F L O
O R
M E
C H
A N
IC
A
L P
L A
N
-1
.0
M
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
KEYED NOTES - MECHANICAL
1 SUSPEND AHU AND ERV FROM STRUCTURE. COORDINATE WITH
STRUCTURAL.
2 EXHAUST AIR THRU LOUVER PER ARCH. BLANK OFF UNUSED PORTIONS
OF GRILLE WITH DARK BRONZE OR BLACK METAL PANEL.
3 LOCATE VERTICAL AHU WITHIN MECHANICAL CLOSET ON 4"
HOUSEKEEPING PAD.
4 ROUTE DUCT TO ARCHITECTURAL LOUVER INTEGRATED ABOVE DOOR
FRAME.
5 CEILING LOUVER PER ARCH. PROVIDE 50% FREE AREA. PROVIDE BIRD
SCREEN TO DUCT OPENING.
6 COORDINATE AND CONCEAL THERMOSTAT CONDUIT WITH ELECTRICAL
CONDUIT. MATCH ELECTRICAL DEVICE ELEVATION.
7 ALIGN CONCEALED SLOT WITHIN CEDAR PLANK. PROVIDE BLACK
INTERIOR PLENUM FINISH.
8 MANUAL BALANCING DAMPER IN RISER.
9 UNDERFLOOR AIR DIFFUSER LOCATED WITHIN TRENCH. PROVIDE
INSULATION LINER AND ACCESS THRU TOP OF ASSEMBLY.
COORDINATE WITH STRUCTURAL.
10 ROUTE HDPE DUCTWORK BELOW GRADE. COORDINATE WITH
STRUCTURAL.
11 EXHAUST AIR THRU LOUVER PER ARCH. ALIGN DUCT TO TOP OF
FRAME. BLANK OFF UNUSED PORTIONS OF GRILLE WITH DARK BRONZE
OR BLACK METAL PANEL.
12 COORDINATE DUCTWORK WITH LOCATION OF ELECTRICAL RECESSED
FLOOR BOX.
13 SUSPEND INLINE EXHAUST FAN FROM STRUCTURE. REFER TO DETAIL
ON M501.
1/4" = 1'-0"
FIRST FLOOR SHEET METAL PLAN
M
M 301
1 2
B
ERV-1
AHU-1 16"x10"
WH-1
16"x10"
12"x12"
6"ø
38"x14" "x
"x
500 CFM EA TO
LOUVER PER ARCH
400 CFM SA TO
LOUVER PER ARCH
400 CFM SA TO
LOUVER PER ARCH
500 CFM EA TO
LOUVER PER ARCH
900 CFM EA
THRU LOUVER
PER ARCH
"x
"x
BALANCING DAMPER
6"ø
16"x10"
"x
REFRIG DN
BELOW GRADE
TO HEAT PUMPS
900 CFM
OA INTAKE
FIRST FLOOR
100' - 0"
B.O. BEAM
109' - 6"
1 21 2
ROOF
111' - 0"
ERV-1
WH-1
M
IN
H E A D H
E
IG
H T
AHU-1
BO PC
99' - 0"
4" SAN
S A N
/2
C W
32"x4" SA TO
ARCH LOUVER
32"x4" EA TO
ARCH LOUVER
10"x16"
V
C W
2" CW
10"x16"
CP-1
900 CFM EA
TO LOUVER
14"x38"
3" SAN
C W
V
2" CW
4" SAN
FIRST FLOOR
100' - 0"
B.O. BEAM
109' - 6"
5 65 6
ROOF
111' - 0"
M 301
BO PC
99' - 0"
AHU-2
ROUTE 18"x6" SA BELOW
GRADE. COORDINATE
PENETRATIONS WITH
STRUCTURAL
20"x20"
6"x18"ø
"x
MOTORIZED CONTROL
DAMPER
BALANCING DAMPER
REFRIG
TO HP-2
FIRST FLOOR
100' - 0"
B.O. BEAM
109' - 6"
CD CD
M 301
BO PC
99' - 0"
MOTORIZED CONTROL
OUTDOOR AIR DAMPER
OUTDOOR AIR THRU
LOUVERED EXTERIOR
CEILING PER ARCH
OA INTAKE WITH BIRDSCREEN.
COORDINATE WITH PRECAST
OPENING
"x
10"x16"
6"x10"
"x
AHU-2
20"x20"
4" HOUSEKEEPING PAD
RETURN AIR
THRU LOUVER
PER ARCH
REFRIG
TO HP-2
10"x6" EA TO
EXTERIOR LOUVER
EF-1
ELEC.
PANEL
VFD
FD-1
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
T R
U C
T
IO
N D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
E N
L A
R G
E D
M E
C H
A N
IC
A
L P
L A
N S
S
E C
T
IO
N S
-1
.0
M
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
1/2" = 1'-0"M 301
1 ENLARGED MECHANICAL PLAN - SUPPORT ROOM
1/2" = 1'-0"M 301
2 MECHANICAL SECTION - SUPPORT ROOM
1/2" = 1'-0"M 301
4 AHU-2 SECTION
1/2" = 1'-0"M 301
3 ENLARGED MECHANICAL PLAN - NATURE CENTER CLOSET
KEYED NOTES - MECHANICAL
1 SUSPEND AHU AND ERV FROM STRUCTURE. COORDINATE WITH
STRUCTURAL.
2 EXHAUST AIR THRU LOUVER PER ARCH. BLANK OFF UNUSED PORTIONS
OF GRILLE WITH DARK BRONZE OR BLACK METAL PANEL.
3 LOCATE VERTICAL AHU WITHIN MECHANICAL CLOSET ON 4"
HOUSEKEEPING PAD.
4 ROUTE DUCT TO ARCHITECTURAL LOUVER INTEGRATED ABOVE DOOR
FRAME.
5 CEILING LOUVER PER ARCH. PROVIDE 50% FREE AREA. PROVIDE BIRD
SCREEN TO DUCT OPENING.
6 COORDINATE AND CONCEAL THERMOSTAT CONDUIT WITH ELECTRICAL
CONDUIT. MATCH ELECTRICAL DEVICE ELEVATION.
7 ALIGN CONCEALED SLOT WITHIN CEDAR PLANK. PROVIDE BLACK
INTERIOR PLENUM FINISH.
8 MANUAL BALANCING DAMPER IN RISER.
9 UNDERFLOOR AIR DIFFUSER LOCATED WITHIN TRENCH. PROVIDE
INSULATION LINER AND ACCESS THRU TOP OF ASSEMBLY.
COORDINATE WITH STRUCTURAL.
10 ROUTE HDPE DUCTWORK BELOW GRADE. COORDINATE WITH
STRUCTURAL.
11 EXHAUST AIR THRU LOUVER PER ARCH. ALIGN DUCT TO TOP OF
FRAME. BLANK OFF UNUSED PORTIONS OF GRILLE WITH DARK BRONZE
OR BLACK METAL PANEL.
12 COORDINATE DUCTWORK WITH LOCATION OF ELECTRICAL RECESSED
FLOOR BOX.
13 SUSPEND INLINE EXHAUST FAN FROM STRUCTURE. REFER TO DETAIL
ON M501.
UNION
FLEXIBLE HOSE
CONNECTION
HPS
SHUT-OFF VALVE
HPR
CALIBRATED
BALANCING VALVE
STRAINER
TRAPPED CONDENSATE
HEAT PUMP
PROVIDE VALVE
EXTENSION KIT TO
ALLOW PROPER
INSULATION COVERAGE
CAP INSULATION.
LEAVE NO EXPOSED
INSULATION ANYWHERE
BUTT & SEAL
JOINTS
EXTEND FLASHING UP BEHIND
LOUVER TO TOP OF WATER STOP.
SHEET METAL DUCTWORK.
EXTEND OVER WATER STOP ON
LOUVER PITCH BOTTOM OF DUCT
TRANSITION TOWARD LOUVER
CAULK
THROUGH WALL
FLASHING FOR ENTIRE
LENGTH OF LOUVER
CLIP ANGLE
BIRD SCREEN
DRAINABLE
BLADE LOUVER
NEW EXTERIOR WALL
DAMPER OPERATORAUTO CONTROL
DAMPER BY TEMP.
CONTROL INSTALLER
AREA SERVED: RESTROOMS
TYPE: PACKAGED CONSTANT VOLUME, 900 CFM, BASED ON "RUSKIN" MCV1000E
OUTSIDE AIR: 100% OUTSIDE AIR
WEIGHT: 504 LB
UNIT MOUNTING: SUSPENDED FROM STRUCTURE.
SUPPLY FILTERS: 2" PLEATED MERV 8 FILTER, 0.5" MEAN APD, FILTER MAGNEHILIC GAUGE WITH 0-1" W.C.
RANGE.
EXHAUST FANS: 900 CFM DIRECT DRIVE FAN AT 1.3" ESP, 1 HP, PREMIUM EFFICIENCY MOTOR WITH SHAFT
GROUNDING RINGS.
TOTAL ENERGY RECOVERY CORE: 900 CFM, ALUMINUM TOTAL ENERGY CORE WITH POLYMER MEMBRANE
COATING. 0.5" MAX SUPPLY APD, 1.3" MAX EXHAUST APD, 1 HP PREMIUM EFFICIENCY MOTOR WITH SHAFT
GROUNDING RING. OUTDOOR AIR AND EXHAUST AIR DAMPERS AND ACTUATORS PROVIDED BY MANUFACTURER.
SUMMER PERFORMANCE: (55% MIN TOTAL EFFECTIVENESS)
ENTERING OUTDOOR AIR: 89.4°F DB, 73.1°F WB
LEAVING OUTDOOR AIR: 78.9°F DB, 67.5°F WB
ENTERING EXHAUST AIR: 75°F DB
WINTER PERFORMANCE: (71.6% MIN TOTAL EFFECTIVENESS)
ENTERING OUTDOOR AIR: 2.2°F DB
LEAVING OUTDOOR AIR: 51.7°F DB
ENTERING EXHAUST AIR: 70°F DB
SUPPLY FANS: 900 CFM DIRECT DRIVE FAN AT 0.5" ESP, 1 HP, PREMIUM EFFICIENCY MOTOR WITH SHAFT
GROUNDING RINGS.
ELECTRICAL: 230/1/60 AND SINGLE POINT POWER CONNECTION. DISCONNECT PROVIDED BY MANUFACTURER.
PLAN ELEVATION
OA IN
EA OUTSA OUT
EA IN
3' - 8.25"
.6
.2
TYPE: 3 TON NOMINAL AIR SOURCE HEAT PUMP
SERVES: RESTROOM
BASED ON: "TRANE", INDOOR MODEL TA, OUTDOOR MODEL 4TWR7
WEIGHT: 210 LBS
REFRIGERANT: R-410A, 1 CIRCUIT @ 9 LB/CIRCUIT
COOLING PERFORMANCE: 900 CFM, 35.9 MBH NET CAPACITY, 26 MBH SENSIBLE CAPACITY,
9.82 MBH LATENT CAPACITY, 80F EDB, 67F EWB, 56.7F LDB, 55.7F LWB.
HEATING PERFORMANCE: 900 CFM, 34 MBH @ 47F (3.9 COP), 21.2 MBH @ 17F (2.6 COP),
70F EDB, 17F OADB, 88.7F LDB.
BACKUP ELECTRIC HEAT: 900 CFM, 70F EDB, 14.4F ATR @ 4.8 KW (240V). SUPPLEMENTAL
ELECTRIC HEAT PROVIDED AS A BACKUP FOR WINTER OPERATION. BUILDING IS INTENDED TO BE
CLOSED DURING THE WINTER SEASON.
SUPPLY FAN: VARIABLE SPEED VORTICA EC MOTOR.
ELECTRICAL: SINGLE-POINT POWER CONNECTION, UNIT MOUNTED DISCONNECT, 240/1/60, 21
TOTAL MCA, 35 TOTAL MOCP.
INDOOR UNIT CONFIGURATION:
RESTROOM: HORIZONTAL SUSPENDED.
NATURE CENTER: VERTICAL ON 4" HOUSEKEEPING PAD.
OUTDOOR UNIT: TWO STAGE HEAT PUMP, 230/1/30, 21 MCA, 35A MAX FUSE SIZE.
OPTIONS: PROVIDE WITH ACOUSTICAL PANELS, VIBRATION ISOLATION, BACNET
COMMUNICATION PACKAGE, PROVIDE UNIT SHUTDOWN CONTROLS WITH TIME DELAYED
WINDOW/DOOR SENSORS. DISCONNECT PROVIDED BY MANUFACTURER.
PLAN
(HORIZONTAL)
ELEVATION
(HORIZONTAL)
/8
21 3/4"
/2
GRADE
AHU-1
36,000 BTU CLG
34,000 BTU HTG
HP-2
36,000 BTU
TS
HP-1
36,000 BTU
AHU-2
TS
36,000 BTU CLG
34,000 BTU HTG
DUCTWORK GENERAL NOTES
90° TEELO-LOSS TEE CONICAL TEE
45° CONICAL TEE MITERED ELBOW45° LATERAL
ENLARGEMENT ANGLE TO BE
22 1/2° OR LESS. CONTRACTION
ANGLE TO BE 45° OR LESS
90° SECTIONED ELBOW
9"~ AND LARGER
SPIRAL DUCT
WELDED OR GROOVED SEAMS
COLLAR BRUSHED W/ SEAL.
COMPOUND BEFORE ASS'T
TRANSITION
RECT. OR OVAL DUCT
ORIFICE
(R) REDUCER
(W/ OR W/OUT ORIFICE)
DIE STAMPED ELBOW
8"~ AND SMALLER
0°-35° 36°-71° 72°-90°
SLICE IN ROUND DUCT
USE SLICES RATHER THAN
ROUND - RECT. - ROUND
WHERE d/D IS GREATER
THAN 2/3
22 1/2° MAX.
d
ROUND - RECT. - ROUND
W=750
OFFSET
NO. OF SECTIONSANGLE
1. ALL JOINTS, CORNERS AND SEAMS TO BE FULLY
SEALED WITH SMACNA APPROVED DUCTWORK
SEALANT.
2. ALL DUCTWORK IS TO BE LEAK TESTED AT PRESSURES
SPECIFIED.
3. ALL RADIUS ELBOWS SHALL HAVE MINIMUM 1.5
CENTERLINE RADIUS
4. USE MITERED ELBOW WITH TURNING VANES WHEN
CENTERLINE RADIUS IS LESS THAN 1.5.
D d
22.50° MAX
D
MAX.
3d
D D d
MIN.
2D
EXTEND FLASHING UP BEHIND
LOUVER TO TOP OF WATER STOP.
SHEET METAL DUCTWORK.
EXTEND OVER WATER STOP ON
LOUVER PITCH BOTTOM OF DUCT
TRANSITION TOWARD LOUVERCAULK
THROUGH WALL
FLASHING FOR ENTIRE
LENGTH OF LOUVER
CLIP ANGLE
BIRD SCREEN
DRAINABLE
BLADE LOUVER
BLANK-OFF PANEL
WHERE APPLICABLE
LOW PRESSURE MAIN
REFER TO PLAN FOR
SIZE/SHAPE
SPIRAL DIST.
DUCTWORK
45° HARD ELBOWS
ON ALL BENDS
MANUAL BALANCE DAMER
WITH QUAD. LOCK
VERIFY CEILING TYPE WITH
ARCH CEILING PLANS
INSULATION - REFER
TO SPECIFICATIONS
INSULATED SLOT DIFFUSER
ADJUSTABLE VANES
SEE SPECIFICATIONS FOR SEALING
AND USING TY-WRAP TOOL OR
REUSABLE SS DRAW BAND
MAXIMUM OF 3 FEET OF FLEX
DUCT TO CONNECT TO PLENUM.
FLEX DUCT SHAL BE USED FOR
ALIGNMENT ONLY. ABRUPT TURNS
OR JOGS ARE NOT ACCEPTABLE.
NOTES
1. OFFSET WITH FLEX DUCT SHALL NOT EXCEED 30° AND SHALL BE
GRADUAL. OFFSETS IN EXCESS OF 30° SHALL BE HARD DUCTED.
2. AT EXTERIOR WALLS, BLOW PATTERN SHALL BE ADJUSTED SO
ONE SLOT DIRECTS AIR DOWN AGAINST THE WALL AND
REMAINING SLOTS BLOW ACROSS CEILING TOWARDS INTERIOR.
PRESSURE GAGE
INLINE
PUMP
ECCENTRIC REDUCER
W/ LEVEL SIDE UP
CHECK VALVE
BALL VALVE
FLANGED CONNECTION
BALL VALVE
BALL VALVE
STRAINER
INSULATED EXHAUST DUCT - REFER
TO PLAN FOR SIZE
IN-LINE CABINET FAN.
SHEET METAL TRANSITION.
HANG UNIT FROM BULIDING STRUCTURE
W/ VIBRATION ISOLTATION
ECM FAN MOTOR WITH SPEED
CONTROL ON FAN HOUSING
EXHAUST DUCT - REFER TO
PLAN FOR SIZE
FLEX CONNECTION (TYP.)
EXHAUST / RELIEF PLENUM - REFER
TO PLANS
CURTAIN WALL
FINISHED FLOOR
TRENCH HEATER WITH 2-SIDED
FLANGED DIFFUSER. INSET
FLANGE TO INSTALL FLUSH WITH
FINISH FLOOR
ADJUSTABLE LEGS
12"x4"Ø
OVAL DUCT CONNECTION
SHEET METAL SLEEVE
GRAVEL INFILL
3/4" FLANGES TO SUPPORT AT SLAB
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
M E
C H
A N
IC
A
L S
C H
E D
U L E
S A
N D
D E
T A
IL
S
-1
.0
M
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
GRILLES, REGISTERS, & DIFFUSERS BASED ON PRICE
MARK PANEL SIZE NECK SIZE MODEL CFM RANGE VCD THROW MATERIAL FINISH INSTALLATION REMARKS
SA-1 48" x (1) 1" SLOT 6"Ø AS 60-300 NO 5-8-17 ALUMINUM DARK BRONZE LINEAR CEILING 1
EA-1 48" x (1) 1" SLOTS 6"Ø AS 250 - 500 YES - ALUMINUM DARK BRONZE LINEAR CEILING 1
SCALE: NONE
HEAT PUMP PIPING DETAIL
SCALE: NONE
TYPICAL PIPE INSULATION AND
VALVE HANDLE EXTENSION DETAIL
SCALE: NONE
LOUVER W/ MOTORIZED DAMPER DETAIL
SCALE: NONE
ERV-1
SCALE: NONE
AHU-1/AHU-2 & HP-1/HP-2
NOTES:
1 CONCEALED FRAME SLOT DIFFUSER WITH ENGINEERED PLENUM, PROVIDE DARK BRONZE OR BLACK INTERIOR PLENUM FINISH.
PUMPS BASED ON BELL & GOSSETT
MARK MODEL FLOW RATE (GPM)
HEAD
(FT) PEIcl
MOTOR DATA
SYSTEM LOCATION REMARKSHP BHP RPM
CP-1 ECOCIRC 20-18 2 12 - 0.1 0.1 2800 DOMESTIC HOT WATER RETURN 103 SUPPORT 1, 2
UNDERFLOOR AIR DISTRIBUTION TERMINAL - HEATING TROUGH BASED ON AIR FIXTURE
MARK CFM RANGE MODEL TROUGH SIZE SUPPLY PRESSURE GRILLE FINISH GRILLE MATERIAL
HEATING ELEMENT
REMARKS
KW VOLTAGE
TR-1 0 - 300 CLEMIT-06-048-06-00-24-10 4'-0" X 10" 0.05" BLACK OR DARK BRONZE ALUMINUM 1.0 240 1
NOTES:
1 PROVIDE PEDESTAL FEET FOR INSTALLATION WITHIN CONCRETE TROUGH. PROVIDE LINER INSULATION. PROVIDE WITH ONE ROUND OPENING.
EXHAUST FANS BASED ON GREENHECK
MARK MODEL TYPE AIR FLOW (CFM)
ESP
(IN WC) SONES
MOTOR
REMARKSEC MOTOR NOMINAL HP BRAKE HP RPM VOLTAGE
EF-1 SQ-75-VG INLINE DIRECT DRIVE 300 0.10 5.5 Yes 0.17 0.17 1550 115/1 1, 2, 3
NOTES:
1. INTERLOCK EXHAUST FAN WITH ASSOCIATED DAMPER.
2. PROVIDE WITH VARI-GREEN MOTOR FOR 0-10V SPEED CONTROL FOR BALANCING.
3. PROVIDE WITH MOTORIZED DAMPER.
SCALE: NONE
AHU/HP REFRIGERANT SCHEMATIC
SCALE: NONE
DUCTWORK FITTING DETAILS - ROUND/OVAL
SCALE: NONE
LOUVER INSTALLATION DETAIL
SCALE: NONE
TYPICAL SLOT DIFFUSER BRANCH DETAIL
SCALE: NONE
PUMP - INLINE PIPING DETAIL
SCALE: NONE
EXHAUST FAN DETAIL - INLINE
SCALE: NONE
UFAD TRENCH HEATER DETAIL
NOTES:
1. WET ROTOR PUMP WITH INTEGRATED VARIABLE FREQUENCY DRIVE. CONTROLS BY EQUIPMENT MANUFACTURER.
2. LEAD-FREE BRONZE CIRCULATOR.
T-1
SF-1
SF-1
SF-1
SF-1
SAF
F
IL
T E R S
E C T
IO
N
DPS-1
TS
DP
C O
IL
S
E C T
IO
N
T-4
DP-1
TS
ZONE AIR CONDITIONS
SA OUT
ECM
SF-1
D A M
P E R
OA IN
RA IN
HX PLATE
EA OUT
TSTS
TSTS DP
DP
EAF
SAF
T-3
T-2
DPS-1
T-1
SF-1
SF-1
DPS-2
T-4
EF-1
EF-1 FILTER SECTIO
N
FI
LT
ER
S
EC
TI
O N
SA OUT
DAMPER
D-2
D-2
M
D-1
D-1
M
D A M
P E R
D-1
D-1
M
RA IN
T-3
TS
COMPRESSOR COMPARTMENT
T-2
PS-1
PSL-1
PSH-1
RV-1
COM-1
COM-1
REFER TO MANUFACTURER POINTS LIST.
DWH-1
WH-1
WH-1
HW 120°F
CP-1
T-1
CP-1
CP-1 TS
CW
TS
T-2
HWR
REFER TO MANUFACTURER POINTS LIST.
ELECTRIC HEATING ELEMENT
TR-1
T-1
TS
ZONE AIR CONDITIONS
REFER TO MANUFACTURER POINTS LIST.
T-1
SF-1
SF-1
SF-1
SF-1
SAF
F
IL
T E R S
E C T
IO
N
DPS-1
TS
DP
C O
IL
S
E C T
IO
N
T-4
DP-1
TS
ZONE AIR CONDITIONS
SA OUT
ECM
SF-1
D A M
P E R
DAMPER
D-2
D-2
M
D-1
D-1
M
RA IN
T-3
TS
COMPRESSOR COMPARTMENT
T-2
PS-1
PSL-1
PSH-1
RV-1
COM-1
COM-1
OA IN
REFER TO MANUFACTURER POINTS LIST.
EF-1
EF-1
EXHAUST
AIR IN
EF-1
EXHAUST
AIR OUT
T-1
OS-1
OS TS
ZONE CONDITIONS
D-2
D-2
D A M
P E R
M
REFER TO MANUFACTURER POINTS LIST.
F
IL
E N
U M
B E
R
S T
A T
E I N
D E
X N
U M
B E
R S
C o ns tr uc tio n
F in a l R e co rd
Is su e d f o r
P re lim in a ry
D a te
D E
S
IG
N A
N D
C O
N S
TR
U
C
TI
O N
D
IV
IS
IO
N
D E
P A
R T
M E
N T
O F
T E
C H
N O
L O
G Y
M
A N
A G
E M
E N
T A
N D
B U
D G
E T
S T
A T
E O
F M
IC
H
IG
A
N
A D
A M
P L A
C H
R
A D
IR
E
C T
O R
S T
A T
E F
A C
IL
IT
IE
S
A D
M
IN
IS
T
R A
T
IO
N
T O
W E
R P
IN
K
S T
E R
.C O
M
A L L R
IG
H
T S
R E
S E
R V
E D
S H
E E
T T
IT
L
E
S H
E E
T N
U M
B E
R
O W
N E
R P
R O
J E
C T
T
IT
L E
D A
T E
T E
M P
E R
A T
U R
E C
O N
T R
O L S
-1
.0
M
A U
G U
S T
M
IL
L
IK
E N
N A
T U
R E
C E
N T
E R
A T
A R
C H
R O
C K
M a c k in a c I s la n d
M ic h ig a n
S T
A T
E O
F M
IC
H
IG
A
N
/2
.T
A P
J U
L Y
A U
G U
S T
SEQUENCE OF OPERATIONS
NOTE: ALL LABOR, MATERIAL, EQUIPMENT AND SOFTWARE NOT SPECIFICALLY INDICATED
WITHIN CONTROLS DRAWINGS THAT IS REQUIRED TO MEET THE FUNCTIONAL INTENT
OF THE SEQUENCE OF OPERATIONS SHALL BE PROVIDED WITHOUT ADDITIONAL
COST. POINT LISTS SHALL BE A GUIDE TO THE POINTS REQUIRED FOR CONTROL
SYSTEM. FINAL POINTS SHALL BE DETERMINED BY SEQUENCE OF OPERATIONS. ALL
SET POINTS SHALL BE OPERATOR ADJUSTABLE THROUGH THE BMS. ALL POINTS
SHALL BE TRENDABLE.
HEAT PUMP SYSTEM W/ ERV CONTROLS - RESTROOMS
1. PROVIDE DIRECT DIGITAL CONTROLS (DDC) FOR SYSTEM OPERATION. HEAT PUMP IS A
COMBINATION OF A VARIABLE VOLUME FAN, VARIABLE SPEED REFRIGERANT
COMPRESSOR, WITH 100% OUTDOOR BY ENERGY RECOVERY VENTILATOR WITH EXHAUST
AND SUPPLY FANS, OUTDOOR AND BY-PASS AIR DAMPERS, ENERGY RECOVERY PLATE, AIR
TEMPERATURE SENSORS AND MANUFACTURER CONTROLLER.
2. VARIABLE REFRIGERANT FLOW (VRF) HEAT PUMP SYSTEMS SHALL INCLUDE SIMPLE WIRED
REMOTE CONTROLLER WITH MULTI-FUNCTION LCD DISPLAY. VRF SYSTEM CONTROLLER
SHALL BE A BACNET PROTOCOL INTELLIGENT FIELD PANEL TO COMMUNICATE BETWEEN
INDOOR AND OUTDOOR UNITS. THE CONTROLLER UTILIZES LOCAL AREA NETWORK TO
PROVIDE A WEBPAGE USER INTERFACE.
3. ADJUSTABLE SCHEDULE BASED ON THE FOLLOWING:
A. SCHEDULED WITH BUILDING SCHEDULE.
B. BY OPERATOR COMMAND.
4. ADJUSTABLE SETPOINTS:
A. OCCUPIED 74°F COOLING / 70°F HEATING
B. UNOCCUPIED 85°F COOLING / 60°F HEATING
C. NORMAL WINTER/OFF SEASON MODE SHUTDOWN
D. WINTER/OFF SEASON BACKUP MODE 55°F HEATING
5. START/STOP, CONTROLLED DEVICES SHALL RESPOND AS FOLLOWS:
A. WHEN INDEXED TO STOP: DISABLE HEAT PUMP COMPRESSOR, DISABLE FANS (HEAT
PUMP AND ERV), OUTDOOR AND EXHAUST DAMPERS SHALL BE 100% CLOSED (NC),
BYPASS AIR DAMPER SHALL BE 100% OPENED (NO).
B. WHEN INDEXED TO START: ENABLE HEAT PUMP SUPPLY FAN WHICH RUNS
CONTINUOUSLY IN OCCUPIED MODE, AFTER DELAY OF FIVE (5) MINUTE HOLD, ENABLE
OCCUPIED TEMPERATURE CONTROL.
6. OCCUPIED TEMPERATURE CONTROL – SYSTEM CONTROLLER SHALL MODULATE HEAT PUMP
COMPRESSOR TO MAINTAIN AN ADJUSTABLE SPACE TEMPERATURE SETPOINT MEASURED
BY A SPACE TEMPERATURE THERMOSTATS.
A. ENERGY RECOVERY – WILL BE ENABLED WHEN THE HEAT PUMP IS IN OCCUPIED MODE.
7. FILTER MONITORING – SYSTEM CONTROLLER SHALL MONITOR AND ALARM FILTER
PRESSURE DIFFERENTIAL PRESSURE DROPS FOR THE FOLLOWING:
A. PRE-FILTERS FOR ERV AND HP:
a. MONITOR PRESSURE DROP
b. ALARM SETPOINT 0.75"W.C. (ADJ.)
8. UNOCCUPIED TEMPERATURE CONTROL:
A. SYSTEM CONTROLLER SHALL CYCLE UNIT ON WHEN A CALL FOR HEAT/COOL IS
INITIATED BY SPACE TEMPERATURE SENSOR DURING UNOCCUPIED MODE.
a. OUTDOOR AND EXHAUST AIR DAMPERS 100% CLOSED,BYPASS AIR DAMPER 100%
OPENED.
b. DISABLE ERV FANS.
c. SYSTEM DISABLED UPON SATISFYING THE CALL.
9. OCCUPIED NATURAL VENTILATION CONTROL:
A. PROVIDE AUXILIARY CONTACT FROM WINDOW CONTACT SENSORS (WIRED IN SERIES)
TO AHU-1. UPON WINDOW CONTACT SENSORS OPEN AND AFTER A 15 MIN (ADJ)
DELAY, AHU-1/HP-1 SHALL SHUT DOWN.
10. INITIAL START-UP (OPTIMAL START) CONTROL – SYSTEM CONTROLLER SHALL ENABLE UNIT
PRIOR TO SCHEDULED OCCUPANCY UTILIZING OPTIMUM START LOGIC TO ADJUST
STARTUP TIME FOR SYSTEM.
A. BASED ON SPACE TEMPERATURE AND HISTORIC ELAPSE TIME TO REACH SETPOINT.
B. SYSTEM SHALL BE ENABLED AND PROVIDE HEATING AND COOLING BASED ON THE
SPACE TEMPERATURE SENSOR TO BRING SPACE TO OCCUPIED SETPOINT.
a. ENABLE HEAT PUMP SUPPLY FAN.
b. OUTDOOR AND EXHAUST AIR DAMPERS SHALL BE 100% CLOSED, BYPASS AIR
DAMPER SHALL BE 100% OPENED WITH ERV DISABLED.
c. SYSTEM SHALL SWITCH TO OCCUPIED MODE.
11. WINTER/OFF SEASON CONTROL:
A. SYSTEM SHALL SHUTDOWN UPON BUILDING SCHEDULE INDICATING WINTER/OFF
SEASON MODE. THERMOSTAT SHALL BE OVERIDDEN TO NOT ALLOW FOR SYSTEM
STARTUP DURING OFF SEASON SCHEDULE.
12. WINTER/OFF SEASON BACKUP HEATING TEMPERATURE CONTROL:
A. THIS MODE IS NOT INTENDED FOR NORMAL USE. WINTER BACKUP HEATING SHALL BE
USED ONLY IN EMERGENCIES OR IN SPECIAL USE CASES.
B. SYSTEM CONTROLLER SHALL CYCLE UNIT ON (WINTER HEATING MODE) WHEN A CALL
FOR HEAT IS INITIATED BY BOTH THE BMS OVERRIDE AND SPACE TEMPERATURE
SENSOR.
a. OUTDOOR AND EXHAUST AIR DAMPERS SHALL BE 100% CLOSED, BYPASS AIR
DAMPER SHALL BE 100% OPENED.
b. DISABLE ERV FANS.
c. SYSTEM DISABLED UPON SATISFYING THE CALL.
d. INITIATE AN ALARM IF SPACE TEMPERATURE FALLS 5°F BELOW SETPOINT.
DOMESTIC HOT WATER SYSTEM CONTROLS
SYSTEM OPERATION BASED ON THE FOLLOWING:
1. SYSTEM IS A COMBINATION OF AN ELECTRIC WATER HEATER WITH MANUFACTURER
CONTROLLER, INLINE HOT WATER RETURN PUMP AND TEMPERATURE SENSORS.
A. PROVIDE DIRECT DIGITAL CONTROLS (DDC) FOR SYSTEM BASED ON THE FOLLOWING:
a. SYSTEM TEMPERATURE SHALL BE CONTROLLED BY MANUFACTURER CONTROLLER.
• AUTOMATIC TEMPERATURE CONTROL: MODULATING OF WATER HEATER TO
MAINTAIN SYSTEM SUPPLY WATER TEMPERATURE SETPOINT OF 120°F (ADJ.).
b. MONITORING OF PACKAGED CONTROLLER.
a. ALARM CONTACT.
b. STATUS (CURRENT SWITCH).
c. CONTROL OF BUILDING RETURN PUMP.
• ENABLED / DISABLED BASED ON TIME OF DAY SCHEDULE.
a. WHEN ENABLED, AND AFTER A DELAY OF TWO (2) MINUTES (ADJ.) WITH NO
STATUS SENSED, DDC SHALL INDICATE A GENERAL ALARM.
b. WHEN ENABLED AND STATUS IS SENSED BY THE CURRENT SENSOR, A
TOTALIZED OF RUN HOURS FOR UNIT WILL BE ACTIVE.
d. MONITORING AND ALARMING OF SUPPLY WATER TEMPERATURE.
• ALARM WHEN TEMPERATURE EXCEEDS HIGH TEMPERATURE OF 125°F (ADJ.)
AND LOW TEMPERATURE OF 110°F (ADJ.).
e. MONITORING OF RETURN WATER TEMPERATURE.
UFAD TRENCH HEATER CONTROLS
SYSTEM OPERATION BASED ON THE FOLLOWING:
1. PROVIDE DIRECT DIGITAL CONTROLS (DDC) FOR UNIT HEATER OPERATION. UNIT HEATER IS
A COMBINATION OF A LINEAR SUPPLY AIR DIFFUSER, ELECTRIC HEATING COIL, AIR
TEMPERATURE SENSOR (UTILIZE AHU-2 THERMOSTAT) AND MANUFACTURER FACTORY
PROGRAMMED MULTI-FUNCTION CIRCUIT BOARD.
2. UNIT HEATER ADJUSTABLE SCHEDULE BASED ON THE FOLLOWING:
A. BUILDING OCCUPIED SCHEDULE.
3. UNIT HEATER ADJUSTABLE SETPOINTS:
A. OCCUPIED 68°F HEATING
B. UNOCCUPIED STANDBY 55°F HEATING
C. UNOCCUPIED OFF SEASON SHUTDOWN
4. OPERATION SHALL BE BASED ON THE FOLLOWING:
A. OPERATION BASED ON WALL MOUNTED THERMOSTAT THAT WILL ENABLE UNIT
WHENEVER SPACE TEMPERATURE FALLS BELOW HEATING SETPOINT.
5. START/STOP, CONTROLLED DEVICES SHALL RESPOND AS FOLLOWS:
A. WHEN INDEXED TO STOP, CONTROLLED DEVICES SHALL RESPOND AS NOTED:
a. DISABLE HEATING ELEMENT.
B. WHEN INDEXED TO START, CONTROLLED DEVICES SHALL RESPOND AS NOTED:
a. ENABLE HEATING ELEMENT.
6. MONITORING AND ALARMING OF THE FOLLOWING:
A. SPACE AIR TEMPERATURE.
SCALE: NONE
HEAT PUMP SYSTEM W/ ERV CONTROLS DIAGRAM - RESTROOMS
SCALE: NONE
DOMESTIC WATER HEATER CONTROLS DIAGRAM
SCALE: NONE
UFAD TRENCH HEATER CONTROLS DIAGRAM
CONTROL POINTS
NUMBER TAG DESCRIPTION ALARM TREND MISC. REMARKS
HEAT PUMP SYSTEM W/ ERV - RESTROOMS
01 SF-1 ENABLE/DISABLE ■ ■ ECM CONTROLLER
01 SF-1 STATUS ■ ■
02 SF-1 SPEED CONTROL ■ ■ ECM CONTROLLER
02 SF-1 ENABLE/DISABLE ■
03 SF-1 ECM MOTOR STATUS ■ ■ ■ ECM CONTROLLER
03 T-1 EXHAUST AIR TEMPERATURE ■
04 SF-1 RUN STATUS ■ ■ ■ ECM CONTROLLER
04 DPS-1 RETURN AIR FILTER STATUS ■ ■
05 DP-1 DRAIN PAN ALARM ■ ■
05 T-2 EXHAUST AIR TEMPERATURE ■
06 DPS-1 FILTER STATUS ■ ■
06 T-3 EXHAUST AIR TEMPERATURE ■
07 DPS-2 OUTDOOR AIR FILTER STATUS ■ ■
07 D-1 BYPASS AIR DAMPER POSITION ■ ■
08 T-4 EXHAUST AIR TEMPERATURE ■
08 D-1 BYPASS AIR DAMPER OUTPUT ■
09 EF-1 ENABLE/DISABLE ■
09 D-2 OUTDOOR AIR DAMPER POSITION ■ ■
10 EF-1 STATUS ■ ■
10 D-2 OUTDOOR AIR DAMPER OUTPUT ■
11 T-1 DISCHARGE AIR TEMPERATURE ■ ■
11 D-1 EXHAUST AIR DAMPER POSITION ■ ■
12 D-1 EXHAUST AIR DAMPER OUTPUT ■
12 T-2 REFRIGERANT TEMPERATURE OUT ■ ■
13 PS-1 LIQUID LINE PRESSURE SENSOR ■ ■
14 PSL-1 COMPRESSOR LOW PRESSURE ■ ■
15 PSH-1 COMPRESSOR HIGH PRESSURE ■ ■
16 COM-1 COMPRESSOR HIGH ■ ■
17 COM-1 COMPRESSOR CONTROL ■ ■
18 RV-1 REVERSING VALVE COMMAND ■ ■ ENERGIZED COOLING/DE-ENERGIZED HEATING
19 T-3 ZONE AIR TEMPERATURE ■
20 T-4 ZONE AIR TEMPERATURE ■
HEAT PUMP SYSTEM - NATURE CENTER
01 SF-1 ENABLE/DISABLE ■ ■ ECM CONTROLLER
02 SF-1 SPEED CONTROL ■ ■ ECM CONTROLLER
03 SF-1 ECM MOTOR STATUS ■ ■ ■ ECM CONTROLLER
04 SF-1 RUN STATUS ■ ■ ■ ECM CONTROLLER
05 DP-1 DRAIN PAN ALARM ■ ■
06 DPS-1 FILTER STATUS ■ ■
07 D-1 RETURN AIR DAMPER POSITION ■ ■
08 D-1 RETURN AIR DAMPER OUTPUT ■
09 D-2 OUTDOOR AIR DAMPER POSITION ■ ■
10 D-2 OUTDOOR AIR DAMPER OUTPUT ■
11 T-1 DISCHARGE AIR TEMPERATURE ■ ■
12 T-2 REFRIGERANT TEMPERATURE OUT ■ ■
13 PS-1 LIQUID LINE PRESSURE SENSOR ■ ■
14 PSL-1 COMPRESSOR LOW PRESSURE ■ ■
15 PSH-1 COMPRESSOR HIGH PRESSURE ■ ■
16 COM-1 COMPRESSOR HIGH ■ ■
17 COM-1 COMPRESSOR CONTROL ■ ■
18 RV-1 REVERSING VALVE COMMAND ■ ■ ENERGIZED COOLING/DE-ENERGIZED HEATING
19 T-3 ZONE AIR TEMPERATURE ■
20 T-4 ZONE AIR TEMPERATURE ■
TROUGH HEATER
01 T-1 ZONE AIR TEMPERATURE ■ ■
02 TR-1 STATUS ■ ■
DOMESTIC WATER HEATER
01 CP-1 ENABLE/DISABLE ■
02 CP-1 STATUS ■ ■
03 WH-1 ALARM STATUS ■ ■
04 WH-1 UNIT ON STATUS ■ ■
05 T-1 DOMESTIC RETURN WATER TEMPERATURE ■
06 T-2 TEMPERED SUPPLY WATER TEMPERATURE ■ ■ 120°F / ALARM HIGH AND LOW TEMPERATURES
INLINE EXHASUT FAN CONTROL POINTS
03 EF-1 FAN SPEED CONTROL ■
04 EF-1 FAN ENABLE/DISABLE ■
05 EF-1 FAN STATUS ■
06 D-2 EXHAUST AIR DAMPER POSITION ■ OPEN/CLOSE
07 D-2 EXHAUST AIR DAMPER OUTPUT ■ OPEN/CLOSE
08 OS-1 OCCUPANCY SENSOR ■
09 T-1 ZONE AIR TEMPERATURE ■
SCALE: NONE
HEAT PUMP SYSTEM CONTROLS DIAGRAM - NATURE CENTER
HEAT PUMP SYSTEM CONTROLS - NATURE CENTER
1. PROVIDE DIRECT DIGITAL CONTROLS (DDC) FOR SYSTEM OPERATION. HEAT PUMP IS A
COMBINATION OF A VARIABLE VOLUME FAN, VARIABLE SPEED REFRIGERANT
COMPRESSOR, INTERLOCKED EXHAUST FAN, AIR TEMPERATURE SENSORS AND
MANUFACTURER CONTROLLER.
2. VARIABLE REFRIGERANT FLOW (VRF) HEAT PUMP SYSTEMS SHALL INCLUDE SIMPLE WIRED
REMOTE CONTROLLER WITH MULTI-FUNCTION LCD DISPLAY. VRF SYSTEM CONTROLLER
SHALL BE A BACNET PROTOCOL INTELLIGENT FIELD PANEL TO COMMUNICATE BETWEEN
INDOOR AND OUTDOOR UNITS. THE CONTROLLER UTILIZES LOCAL AREA NETWORK TO
PROVIDE A WEBPAGE USER INTERFACE.
3. ADJUSTABLE SCHEDULE BASED ON THE FOLLOWING:
A. SCHEDULED WITH BUILDING SCHEDULE.
B. BY OPERATOR COMMAND.
4. ADJUSTABLE SETPOINTS:
A. OCCUPIED 74°F COOLING / 70°F HEATING
B. UNOCCUPIED 85°F COOLING / 60°F HEATING
C. NORMAL WINTER/OFF SEASON MODE SHUTDOWN
D. WINTER/OFF SEASON BACKUP MODE 55°F HEATING
5. START/STOP, CONTROLLED DEVICES SHALL RESPOND AS FOLLOWS:
A. WHEN INDEXED TO STOP: DISABLE HEAT PUMP COMPRESSOR, DISABLE FANS (HEAT
PUMP), OUTDOOR AND EXHAUST DAMPERS SHALL BE 100% CLOSED (NC).
B. WHEN INDEXED TO START: ENABLE HEAT PUMP SUPPLY FAN WHICH RUNS
CONTINUOUSLY IN OCCUPIED MODE, AFTER DELAY OF FIVE (5) MINUTE HOLD, ENABLE
OCCUPIED TEMPERATURE CONTROL.
6. OCCUPIED TEMPERATURE CONTROL – SYSTEM CONTROLLER SHALL MODULATE HEAT PUMP
COMPRESSOR TO MAINTAIN AN ADJUSTABLE SPACE TEMPERATURE SETPOINT MEASURED
BY A SPACE TEMPERATURE THERMOSTATS.
A. ASSOCIATED EXHAUST FAN SHALL OPERATE IN TANDEM.
7. OCCUPIED NATURAL VENTILATION CONTROL:
A. PROVIDE AUXILIARY CONTACT FROM WINDOW CONTACT SENSORS (WIRED IN SERIES)
TO AHU-1. UPON WINDOW CONTACT SENSORS OPEN AND AFTER A 15 MIN (ADJ)
DELAY, AHU-2/HP-2 SHALL SHUT DOWN.
8. FILTER MONITORING – SYSTEM CONTROLLER SHALL MONITOR AND ALARM FILTER
PRESSURE DIFFERENTIAL PRESSURE DROPS FOR THE FOLLOWING:
A. PRE-FILTERS FOR HP:
a. MONITOR PRESSURE DROP
b. ALARM SETPOINT 0.75"W.C. (ADJ.)
9. UNOCCUPIED TEMPERATURE CONTROL:
A. SYSTEM CONTROLLER SHALL CYCLE UNIT ON WHEN A CALL FOR HEAT/COOL IS
INITIATED BY SPACE TEMPERATURE SENSOR DURING UNOCCUPIED MODE.
a. OUTDOOR AND EXHAUST AIR DAMPERS 100% CLOSED,BYPASS AIR DAMPER 100%
OPENED.
b. SYSTEM DISABLED UPON SATISFYING THE CALL.
10. INITIAL START-UP (OPTIMAL START) CONTROL – SYSTEM CONTROLLER SHALL ENABLE UNIT
PRIOR TO SCHEDULED OCCUPANCY UTILIZING OPTIMUM START LOGIC TO ADJUST
STARTUP TIME FOR SYSTEM.
A. BASED ON SPACE TEMPERATURE AND HISTORIC ELAPSE TIME TO REACH SETPOINT.
B. SYSTEM SHALL BE ENABLED AND PROVIDE HEATING AND COOLING BASED ON THE
SPACE TEMPERATURE SENSOR TO BRING SPACE TO OCCUPIED SETPOINT.
a. ENABLE HEAT PUMP SUPPLY FAN.
b. OUTDOOR AND EXHAUST AIR DAMPERS SHALL BE 100% CLOSED.
c. SYSTEM SHALL SWITCH TO OCCUPIED MODE.
11. WINTER/OFF SEASON CONTROL:
A. SYSTEM SHALL SHUTDOWN UPON BUILDING SCHEDULE INDICATING WINTER/OFF
SEASON MODE. THERMOSTAT SHALL BE OVERIDDEN TO NOT ALLOW FOR SYSTEM
STARTUP DURING OFF SEASON SCHEDULE.
12. WINTER/OFF SEASON BACKUP HEATING TEMPERATURE CONTROL:
A. THIS MODE IS NOT INTENDED FOR NORMAL USE. WINTER BACKUP HEATING SHALL BE
USED ONLY IN EMERGENCIES OR IN SPECIAL USE CASES.
B. SYSTEM CONTROLLER SHALL CYCLE UNIT ON (WINTER HEATING MODE) WHEN A CALL
FOR HEAT IS INITIATED BY BOTH THE BMS OVERRIDE AND SPACE TEMPERATURE
SENSOR.
a. OUTDOOR AND EXHAUST AIR DAMPERS SHALL BE 100% CLOSED.
b. SYSTEM DISABLED UPON SATISFYING THE CALL.
c. INITIATE AN ALARM IF SPACE TEMPERATURE FALLS 5°F BELOW SETPOINT.
SCALE: NONE
EXHAUST FAN CONTROLS DIAGRAM
EXHAUST FAN CONTROLS
SYSTEM OPERATION BASED ON THE FOLLOWING:
1. PROVIDE DIRECT DIGITAL CONTROLS (DDC) FOR EXHAUST FAN OPERATION. EXHAUST FAN
IS A COMBINATION OF FAN, AIR TEMPERATURE SENSOR AND MANUFACTURER
CONTROLS.
2. EXHAUST FAN ADJUSTABLE SCHEDULE BASED ON THE FOLLOWING:
A. BUILDING OCCUPIED SCHEDULE.
B. INTERLOCKED OPERATION WITH AHU-2.
3. OPERATION SHALL BE BASED ON THE FOLLOWING:
A. EXHAUST FAN SHALL OPERATE CONTINUOUSLY AT CONSTANT SPEED TO PROVIDE
SPECIFIED AIRFLOW.
4. MONITOR AND ALARM EXHAUST FAN IF COMMANDED ON BUT NOT PROVED ON BY
CURRENT SENSING SWITCH.
SEQUENCE OF OPERATIONS (CONT'D)
BUILDING CONTROLS
EQUIPMENT IS CONTROLLED VIA STANDALONE CONTROLS BY EQUIPMENT MANUFACTURERS.
AUXILIARY DRY CONTACTS SHALL BE PROVIDED WHERE INDICATED TO ALLOW FOR
COMMUNICATION BETWEEN SYSTEMS.
| 40 - MP 001 |
| 21140_ARCH ROCK_MECH_kpitschel |
| MP 001 - MECHANICAL & PLUMBING SYMBOLS, ABBREVIATIONS, AND GENERAL NOTES |
| 40 - MS 101 |
| 21140_ARCH ROCK_MECH_kpitschel |
| MS 101 - MECHANICAL SITE PLAN |
| 43 - P 000 |
| 21140_ARCH ROCK_MECH_kpitschel |
| P 000 - FOUNDATION PLUMBING PLAN |
| 43 - P 101 |
| 21140_ARCH ROCK_MECH_kpitschel |
| P 101 - FIRST FLOOR PLUMBING PLAN |
| 43 - P 150 |
| 21140_ARCH ROCK_MECH_kpitschel |
| P 150 - PLUMBING ROOF PLAN |
| 43 - P 501 |
| 21140_ARCH ROCK_MECH_kpitschel |
| P 501 - PLUMBING SCHEDULES AND DETAILS |
| 44 - M 101 |
| 21140_ARCH ROCK_MECH_kpitschel |
| M 101 - FIRST FLOOR MECHANICAL PLAN |
| 44 - M 301 |
| 21140_ARCH ROCK_MECH_kpitschel |
| M 301 - ENLARGED MECHANICAL PLANS & SECTIONS |
| 44 - M 501 |
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .