Attach 03 - Updated Drawings_06.24.2025.pdf
PDF 39 MB Posted
- Attached to
- Buffalo Creek Work Center Office & Engine Storage Additions Federal contract opportunity
- Solicitation number
- 1282B125R0021
- Issued by
- Department of Agriculture Forest Service
About this file
These architectural drawings detail the Buffalo Creek Work Center Office and Engine Storage Additions project for the United States Department of Agriculture Forest Service, located at 18046 County Road 126 in Buffalo Creek, Colorado. The project involves constructing new office space and an additional engine bay as an addition to the existing Engine Storage building, with work including site utilities, grading, demolition of existing site features, and construction of foundation, building, mechanical, electrical, and plumbing systems. The drawings provide comprehensive technical specifications across multiple disciplines including civil, structural, architectural, mechanical, plumbing, electrical, fire alarm, and technology systems, with detailed plans for a new facility that will improve space utilization and energy efficiency at the Buffalo Creek Work Center.
The drawings specify construction as Type V with Group B occupancy, designed to meet 2021 International Building Codes and various accessibility standards. The new addition will include approximately 1,532 square feet of engine storage, 118 square feet of office/radio room, and a 74 square foot unisex restroom. The project includes optional bid items such as replacing existing siding, adding equipment storage lockers, installing a concrete paving apron, potential demolition of the existing office building, and replacing radiant heaters and sewer service lines. The architectural plans provide extensive details on demolition, site preparation, structural elements, and systems integration for the new facility.
View the file
Other files for this federal contract opportunity
Show all 41
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
LOCATION
PROJECT LOCATION
THESE DRAWINGS COMPLY WITH THE FOREST PLAN AND PROJECT
SPECIFIC NEPA DOCUMENTATION:
RECOMMENDED BY:
I HAVE REVIEWED THE TECHNICAL ASPECTS OF THESE DRAWINGS:
APPROVED BY:
INDEX
PROJECT ADDRESS
LATITUDE: 39°23'18.7"N
LONGITUDE: 105°16'24.0"W
DATE
FOREST ENGINEER
PROJECT MANAGER
REGIONAL ENGINEER
FOREST SUPERVISOR
ENGINEERING/REGIONAL SPECIALIST
[FIELD SUPPORT PROGRAM MANAGER]
DATE
DATE
DATE
DATE
PROJECT LOCATION
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
SOUTH PLATTE RANGER DISTRICT
R2
/2
/2
:4
:4
A
M A u to d e s k D o c s /U
S F
S B u ff a lo
C re e k W o rk
C e n te r/ -0
.0
A
R C
H B
U F
F A
L O
C R
E E
K W
O R
K C
E N
T E
R R
.r v t
COVER SHEET
G1.0 10/15/2024
JFRASER
NP, SH, PJ, JR
2022-08.11
UNITED STATES DEPARTMENT OF AGRICULTURE
ROCKY MOUNTAIN REGION
18046 COUNTY ROAD 126
BUFFALO CREEK, CO 80470
BUFFALO CREEK WORK CENTER - OFFICE
AND ENGINE STORAGE ADDITIONS
ROCKY MOUNTAIN REGION
BUFFALO CREEK, COLORADO
PIKE-SAN ISABEL NATIONAL FOREST & CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
HALF SIZE DRAWINGS
SCALES SHOWN ARE FOR FULL
SIZE (22" X 34") DRAWINGS
Sheet Number Sheet Name
G1.0 COVER SHEET
G1.1 ALTERNATE BID ITEMS
G1.2 EXISTING CONDITIONS - FOR REFERENCE ONLY
CIVIL
C1 NOTES, SYMBOLS, & ABBREVIATIONS SHEET
C2 OVERALL PLAN
C3 DEMOLITION PLAN
C4 SITE PLAN
C5 GRADING AND DRAINAGE PLAN
C6 UTILITY PLAN
C7 OWTS DESIGN REPORT
C8 OWTS SPECIFICATIONS
C9 OWTS DETAILS
C10 OWTS DETAILS
C11 DETAILS
C12 DETAILS
C13 SITE SECTIONS
C14 EROSION CONTROL PLAN
C15 EROSION CONTROL NOTES
C16 EROSION CONTROL DETAILS
STRUCTURAL
S0.0 GENERAL NOTES
S0.1 GENERAL NOTES
S0.2 GENERAL NOTES
S0.3 QUALITY ASSURANCE
S0.4 QUALITY ASSURANCE
S1.0 LOADING DIAGRAMS
S1.1 FOUNDATION PLAN
S1.2 ROOF FRAMING PLAN
S2.0 TYPICAL CONCRETE DETAILS
S2.1 TYPICAL CONCRETE DETAILS
S2.2 CONCRETE DETAILS
S3.0 TYPICAL WOOD DETAILS
S3.1 WOOD DETAILS
S3.2 WOOD DETAILS
S3.3 WOOD DETAILS
S3.4 WOOD DETAILS
S3.5 WOOD DETAILS
ARCHITECTURAL
A1.0 ARCHITECTURAL NOTES & ABBREVIATIONS
D1.1 DEMOLITION FLOOR PLAN
D1.2 DEMOLITION REFLECTED CEILING PLAN
D1.3 DEMOLITION ROOF PLAN
A1.1 SITE PLAN
A1.2 LIFE SAFETY
A1.3 ACCESSIBILITY PLAN
A1.4 BUILDING ASSEMBLIES
A1.5 ABAAS / ABA FIGURES
A2.0 SLAB ON GRADE PLAN
A2.1 FLOOR PLAN
A2.1A AREA PLAN - OFFICE ADDITION
A2.2 REFLECTED CEILING PLAN
A2.3 ROOF PLAN
A2.4 FINISH PLAN
A2.5 FURNITURE PLAN
Sheet Number Sheet Name
A3.1 LOCKER ROOMS ENLARGED PLANS & ELEVATIONS
A3.2 BREAK ROOM ENLARGED PLANS & ELEVATIONS
A4.1 BUILDING ELEVATIONS
A4.2 BUILDING SECTIONS
A5.1 INTERIOR ELEVATIONS
A6.1 NEW WORK WALL SECTIONS
A6.2 EXISTING WALL SECTIONS
A6.3 NEW WORK WALL & ROOF DETAILS
A6.4 EXISTING WALL & ROOF DETAILS
A6.5 CEILING & CASEWORK DETAILS
A6.6 NEW WORK PLAN DETAILS
A6.7 NEW WORK PLAN DETAILS
A7.1 DOOR & HARDWARE SCHEDULES
A7.2 WINDOW TYPES AND DETAILS
MECHANICAL/PLUMBING
M1.0 MECHANICAL LEGEND
MD1.1 MECHANICAL/PLUMBING SITE DEMOLITION PLAN
MD2.1 MECHANICAL HVAC DEMOLITION PLAN
M2.1 MECHANICAL HVAC PLAN
PD2.1 PLUMBING DEMOLITION PLAN
P1.2 PLUMBING SITE PLAN
P2.1 PLUMBING PLAN
P2.2 PLUMBING - DOMESTIC WASTE AND VENT PLAN
P2.3 PLUMBING - ROOF PLAN
P4.1 PLUMBING ISOMETRICS
M5.0 MECHANICAL DETAILS
M6.0 MECHANICAL SCHEDULES
M6.1 MECHANICAL SCHEDULES
ELECTRICAL
E1.0 ELECTRICAL LEGEND
E1.1 ELECTRICAL ONE-LINE DIAGRAM
ED2.1 ELECTRICAL DEMOLITION PLAN
ED2.3 LIGHTING DEMOLITION PLAN
E2.1 ELECTRICAL PLAN
E2.2 ELECTRICAL ROOF PLAN
E2.3 LIGHTING PLAN
E5.0 ELECTRICAL DETAILS
E6.0 ELECTRICAL SCHEDULES
E6.1 ELECTRICAL SCHEDULES
E6.2 ELECTRICAL SCHEDULES
FIRE ALARM
F1.1 SITE LIFE SAFETY PLAN
FA1.1 FIRE ALARM DEMOLITION
FA1.2 FIRE ALARM NEW LAYOUT
TECHNOLOGY
T1.0 TECHNOLOGY LEGEND
T1.1 TECHNOLOGY SITE PLAN
T2.1 TECHNOLOGY FLOOR PLAN
T2.2 TECHNOLOGY REFLECTED CEILING PLAN
T3.1 TECHNOLOGY PLAN
NO. REVISION/ ISSUE DATE
ADDENDUM 02 10/15/2024
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
/2
/2
:4
:4
A
M A u to d e s k D o c s /U
S F
S B u ff a lo
C re e k W o rk
C e n te r/ -0
.0
A
R C
H B
U F
F A
L O
C R
E E
K W
O R
K C
E N
T E
R R
.r v t
ROCKY MOUNTAIN REGION
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
ALTERNATE BID
ITEMS
G1.1 10/15/2024
JFRASER
NP, SH, PJ
2022-08.11
OPTIONAL BID ITEMS LIST:
OI-01 EXISTING SIDING
a. BASE BID: EXISTING TO REMAIN
b. ADD ALTERNATE: REPLACE EXISTING TO MATCH NEW
OI-02 EQUIPMENT STORAGE LOCKERS
a. BASE BID: EXISTING LOCKERS REMAIN
b. ADD ALTERNATE: REPLACE WITH TWO TIER CAGE STYLE EQUIPMENT STORAGE LOCKER SYSTEM
OI-03 PAVING APRON
a. BASE BID: AGGREGATE BASE COURSE (ABC) SECTION.
b. ADD ALTERNATE: PROVIDE HEAVY DUTY CONCRETE PAVING APRON
OI-04 EXISTING OFFICE BUILDING
a. BASE BID: EXCLUDED FROM SCOPE OF WORK
b. ADD ALTERNATE: COMPLETE DEMOLITION AND SITE CLEARING
OI-05 EXISTING ENGINE BAY RADIANT HEATERS
a. BASE BID: EXISTING TO REMAIN
b. ADD ALTERNATE: REPLACE THE EXISTING RADIANT HEATERS IN THE EXISTING ENGINE BAYS. SEE MECH.
OI-06 ENGINE BAY ADDITION
a. BASE BID: ADDITION AND RELATED SCOPE NOT INCLUDED.
b. ADD ALTERNATE: ADDITION AND ALL RELATED WORK AS SHOWN.
OI-07 SEWER SERVICE LINES
a. BASE BID: EXISTING TO REMAIN.
b. ADD ALTERNATE: REPLACE EXISTING RESIDENCE SANITARY SEWER SERVICE LINE TO THE BUILDING, WITH NEW PVC PIPING. CAP EXISTING OFFICE SEWER LINE.
OI-08 WINDOW GRILLES
a. BASE BID: WINDOWS AS SHOWN ON ELEVATIONS
b. ADD ALTERNATE: WINDOW GRILLES AS SHOWN ON WINDOW TYPES SHEET.
NO. REVISION/ ISSUE DATE
01 ADDENDUM 06/26/2024
FD
10' - 10" 10' - 6"
13' - 0 1/2" 2' - 6" 12' - 0" 2' - 0" 12' - 0" 2' - 0" 12' - 0" 2' - 5 1/2"
1532 SF
ENGINE STORAGE
118 SF
OFFICE/ RADIO ROOM
74 SF
UNISEX RR
4 5
C
D
58' - 0"
EX1EX1 EX1
4' - 8" 6' - 4 5/8"
/2
3' - 8"
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
/2
/2
:4
:5
A
M A u to d e s k D o c s /U
S F
S B u ff a lo
C re e k W o rk
C e n te r/ -0
.0
A
R C
H B
U F
F A
L O
C R
E E
K W
O R
K C
E N
T E
R R
.r v t
ROCKY MOUNTAIN REGION
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
EXISTING
CONDITIONS - FOR
REFERENCE ONLY
G1.2 10/15/2024
JFRASER
NPOTTER
2022-08.11
1/4" = 1'-0" A4
LEVEL 1 EXISTING CONDITIONS HALF SIZE DRAWINGS
SCALES SHOWN ARE FOR FULL
SIZE (22" X 34") DRAWINGS
KEYNOTES
EX1 EXISTING STORAGE CASEWORK TO REMAIN.
NO. REVISION/ ISSUE DATE
SYMBOL DESCRIPTION
MECH UNIT (XX.Xk = MECH
UNIT OPERATING WEIGHT
IN KIPS INCLUDING INERTIA
BASE)
PAD THICKNESS
OVERFRAMING
CAST-IN-PLACE CONCRETE
XX.Xk
X" EXTENT OF CONCRETE PAD
YW1 WALLS, Y = (F)ND, (C)IP CONC,
(R)ETAINING, CIP CONC
(S)HEARWALL
FTG MARK (SF = STRIP FTG)
T/FTG EL
F1
XX'-X"
SYMBOL DESCRIPTION
ELEVATION CALLOUT
XXX'-XX"
STEP
SLOPE
KEY NOTE
SUBGRADE
FORM SAVER
DRAWING REVISION NUMBER
CURRENT REVISION CLOUD
X
SERVICE LOAD PROVIDED
FOR SPECIALTY DESIGNER
WELDED-WIRE REINFORCEMENT
SECTION OR
DETAIL CUT
SHEET NUMBER
ELEVATION CUT
SHEET NUMBER
GRID LINES
X
XX
X
XX
SOGXXA
XXX'-XX"
SLAB THICKNESS
TYPE
T/SLAB
SLAB TYPE
CXX
BP-X
COLUMN SIZE OR MARK
BASE PLATE TYPE
NOTES:
1. ITEMS NOT DESIGNED BY M/M ARE SHOWN HALFTONED,
2. ITEMS INCLUDE:
- EXISTING CONSTRUCTION
- PERFORMANCE SPECIFIED ITEMS (STAIRS, RAILINGS, ETC.)
SYMBOL DESCRIPTION
F ORE S T S ERV I CE
DEP
A R TMENT OF AGR I CU LT
UR
E
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
M M
J O
B
P
R
IN
C
IP
A L:
E O
R
P R
O
JE
C T
M A
N A
G E
R
D E
S
IG
N E
R S
LE
A D
R E
V
IT
T E
C H
D
A T
E P
R
IN
T E
D
F
IL
E P
A T
H
/1
/2
:2 0:
P M
A u to d e sk
D o cs
/U S
F S
B uf fa lo
C re e k
W o rk C e n te r/
3.
.S
.0
B uf fa lo
C re e k
W or k C e n te r
A d d iti o n s
S
3.
rv t
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
GENERAL NOTES
S0.0 10/15/2024
SMOLLOY
JAJA
23.1414.S.01
JE
R
E M
Y A
JA
JE
R
E M
Y A
JA
S E
A N
M O
LL
O
Y
.1
4.
S
.0
S E
A N
M O
LL
O
Y N
/A
ABBREVIATIONS
(E) or EXIST Existing
/ Per
@ At
AB Anchor Bolt
ACI American Concrete Institute
ADDNL Additional
AFF Above Finish Floor
ALT Alternate
APA American Plywood Association
APPROX Approximate
ARCH Architect or Architectural
B/ or BO Bottom of
BAL Balance
BD Board
BL Brick Ledge
BLDG Building
BLKG Blocking
BM Beam
BN Boundary Nail
BOT or B Bottom
BRG Bearing
BTWN Between
CC Center to Center
CG Center of Gravity
CIP Cast-In-Place
CJ Control Joint
CL Centerline
CLG Ceiling
CLMS Ceiling/Light/Mechanical/ Superimposed Load
CLR Clear
COL Column
CONC Concrete
CONN Connection
CONST Construction
CONT Continue or Continuous
CONTR Contractor
COORD Coordinate
CSJ Construction Joint
CTR(D) Center(ed) d Penny
D or DL Dead Load
DAS Deformed Anchor Stud db Rebar Diameter
DBL Double
DFS Deferred Submittal
DIA OR Ø Diameter
DIAG Diagonal
DIM Dimension
DN Down
DTL(s) Detail(s)
DWG(s) Drawing(s)
DWL(s) Dowels(s)
E Earthquake Load
E-W East-West
EA Each
EC Epoxy Coated
EE Each End
EF Each Face
EJ Expansion Joint
EL Elevation
EMBED Embedded
EN Edge Nail
ENGR Engineer
EOR Engineer-of-Record
EQ Equal
EQ SP Equally Spaced
EQUIP Equipment
ES Each Side
EW Each Way
EXP Expansion
EXP ANCH Expansion Anchor
EXT Exterior
FAB Fabricate
FD Footing Dowel
FF Finished Floor
FIN Finish(ed)
FLG Flange
FLR Floor
FND Foundation
FO Face of
FRAM Framing
FS Far Side
FT Foot or Feet
FTG Footing
FV Field Verify
GA Gage or Gauge
GALV Galvanized
GC General Contractor
GL Glu-lam
GLB Glu-lam Beam
GR Grade or Grind
HAS or HDAS Headed Anchor Stud
HD Headed or Holddown
HDAR Headed Anchor Rod
HDG Hot Dipped Galvanized
HK Hook
HORIZ Horizontal
HT Height
I.F. Inside Face
IN Inch
INT Interior
IS Inside Diameter
JST Joist
JT Joint k Kip
L Length or Live Load
LB(S) Pound(s)
LCE Compression Embedment
LCS Compression Lap Splice
LDH Hook Development Length
LG Length
LL Live Load
LLH Long Leg Horizontal
LLV Long Leg Vertical
LOC(s) Location(s) or Locate
LONG Longitudinal
Lr Roof Live Load
LSH Long Side Horizontal
LSL Laminated Strand Lumber
LSV Long Side Vertical
LT Light
LTE Tension Embedment
LTS Tension Lap Splice Length
LVL Level or Laminated Veneer Lumber
MAS Masonry
MATL Material
MAX Maximum
MECH Mechanical
MEP Mech/Elect/Plumb
MIL Micro-Lam
MIN Minimum
MISC Miscellaneous mm Millimeter
MNFR Manufacturer
MTL Metal
N North
N-S North-South
NIC Not in Contract
NM Non-Metallic
NO OR # Number
NOM Nominal
NS Non-Shrink or Near Side
NTS Not to Scale
NWC Normal Weight Concrete
O.F. Outside Face
OAE Or Approved Equivalent
OC On Center
OD Outside Diameter
OH Opposite Hand
OPNG Opening
OPP Opposite
OVS Oversized
PAF Powder Actuated Fastener
PCA Portland Cement Association
PEN Penetration
PERP Perpendicular
PL Plate (Steel)
PLF Pounds Per Lineal Foot
PREFAB Prefabricated
PRELIM Preliminary
PSF Pounds Per Square Foot
PSI Pounds Per Square Inch
PSL Parallel Strand Lumber
QTY Quantity
R Radius or Rain Load
RAD Radius
RC Reinforced Concrete
RE: or REF Refer to (Reference)
REINF Reinforce(ing)(d)(ment)
REQD Required
REQT(s) Requirement(s)
RET Return
RO Rough Opening
S South
SCHED Schedule
SECT Section
SIM Similar
SL Snow Load
SLH Short Leg Horizontal
SLRS Seismic Load Resisting System
SLV Short Leg Vertical
SOG Slab on Grade
SP Space(s)
SP @ Space at
SPECS Specifications
SPRT Support
SS Stainless Steel
SSL Short-Slotted
STD Standard
STIFF Stiffener
STL Steel
STR Structural
SW Shearwall
SYM Symmetrical
T Top or Thermal Load
T&B Top and Bottom
T/ or T.O. Top of
THK Thick or Thickness
TL Total Load
TOC Top of Concrete
TOF Top of Footing
TOP Topping
TOS Top of Steel
TOW Top of Wall
TRANS Transverse
TYP Typical
ULT Ultimate
UNO Unless Noted Otherwise
Vasd Service Level/Nominal Design Wind Speed
VERT Vertical
VIF Verify in Field
Vult Ultimate Design Wind Speed
W Wind Load
W/ With
W/O Without
WD Width or Wood
WF Wide Flange
WP Working Point or Waterproofing
WPS Welding Procedure Specification
WT Weight
WWR Welded Wire Reinforcing
WxH Width x Height
SYMBOL LIST
1) GENERAL:
1A) ENGINEER: REFERENCES ON THE STRUCTURAL DRAWINGS TO ‘ENGINEER’ MEAN THE STRUCTURAL ENGINEER OF RECORD. OTHER ENTITIES ARE SPECIFICALLY NOTED AS “CONTRACTOR’S ENGINEER”, “MECHANICAL ENGINEER”, ETC.
1B) THESE NOTES SUPPLEMENT THE SPECIFICATIONS, WHICH SHALL BE REFERENCED FOR ADDITIONAL
REQUIREMENTS.
1C)UNDERGROUND UTILITIES: LOCATE EXISTING UTILITIES AND NOTIFY ARCHITECT OF EXISTING UTILITIES OR
SUBGRADE CONDITIONS WHICH INTERFERE WITH WORK.
1D)STRUCTURAL ELEMENTS ARE CENTERED ON GRID LINES AND GRID LINE INTERSECTIONS UNLESS
DIMENSIONED OTHERWISE.
2) USE OF DRAWINGS:
2A) DO NOT SCALE DRAWINGS.
2B) DETAILS ON DRAWINGS TAKE PRECEDENCE OVER GENERAL NOTES AND TYPICAL DETAILS.
2C)DETAILS NOTED TYPICAL APPLY TO ALL SIMILAR CONDITIONS. WHERE NO SPECIFIC DETAILS ARE SHOWN, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK ELSEWHERE ON THE PROJECT.
2D)WHERE DISCREPANCIES OCCUR BETWEEN PLANS, DETAILS, GENERAL NOTES AND SPECIFICATIONS:
- CONTACT THE ARCHITECT PRIOR TO PROCEEDING WITH CONSTRUCTION
- THE MORE STRINGENT REQUIREMENTS SHALL GOVERN FOR BIDDING / PRICING
3) EXISTING STRUCTURES:
3A) CONTRACT DOCUMENTS HAVE BEEN PREPARED USING AVAILABLE DRAWINGS AND SITE OBSERVATION AS
PERMITTED BY ACCESS RESTRICTIONS DURING DESIGN.
3B) DURING CONSTRUCTION, THE CONTRACTOR MAY ENCOUNTER EXISTING CONDITIONS WHICH ARE NOT KNOWN OR ARE AT VARIANCE WITH PROJECT DOCUMENTATION. CONTRACTOR SHALL NOTIFY THE ARCHITECT
OF ALL CONDITIONS NOT PER THE CONTRACT DOCUMENTS. EXAMPLES INCLUDE:
- SIZES OR DIMENSIONS OTHER THAN THOSE SHOWN
- DAMAGE OR DETERIORATION TO MATERIALS AND COMPONENTS
- CONDITIONS OF INSTABILITY OR LACK OF SUPPORT
- ITEMS NOTED AS EXISTING ON THE DRAWINGS BUT NOT FOUND IN THE FIELD
3C)PREPARE DIMENSIONAL DRAWINGS OF ALL DISCOVERED ITEMS.
3D)CONTRACTOR SHALL FIELD VERIFY ALL EXISTING STRUCTURAL CONDITIONS PRIOR TO SUBMITTING SHOP
DRAWINGS.
3E) CONTRACTOR SHALL MAKE ALLOWANCE FOR THE RESOLUTION OF SUCH DISCOVERIES IN THE
CONSTRUCTION SCHEDULE.
3F) SUBMIT A DIMENSIONED DRAWING OF ALL NEW OPENINGS THROUGH EXISTING STRUCTURE AND SECURE APPROVAL PRIOR TO CUTTING. NEW OPENING MAY BE EITHER SHOWN ON THE CONTRACT DOCUMENTS OR
PROPOSED BY THE CONTRACTOR. DRAWING SHALL SHOW:
- VERTICAL & HORIZONTAL LOCATION AND SIZE OF NEW OPENING(S)
- ALL EXISTING OPENINGS IN THE VICINITY OF THE NEW OPENING(S)
- ALL EXISTING STRUCTURE (BEAMS, COLUMNS, SLABS, WALLS, ETC) IN THE VICINITY OF THE NEW
OPENING(S)
- ALL REINFORCING BAR SIZES AND POSITIONS (LAYOUT LOCATION AND DEPTH) CONFLICTING WITH OR IN
THE VICINITY OF THE NEW OPENING(S).
4) COORDINATION:
4A) STRUCTURAL DRAWINGS ARE NOT STAND-ALONE DOCUMENTS AND ARE INTENDED TO BE USED IN CONJUNCTION WITH CIVIL, ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND DRAWINGS FROM OTHER DISCIPLINES. THE CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS
INTO SHOP DRAWINGS AND WORK.
4B) COORDINATE DIMENSIONS OF ALL OPENINGS, BLOCKOUTS, DEPRESSIONS, ETC., WITH ARCHITECTURAL DRAWINGS, DRAWINGS FROM OTHER DISCIPLINES, AND FIELD CONDITIONS PRIOR TO SHOP DRAWING
SUBMITTAL.
4C)SEE ARCHITECTURAL PLANS FOR INTERIOR PARTITIONS. PARTITION FRAMING SHALL BE CONNECTED TO THE PRIMARY STRUCTURE IN SUCH A WAY SO AS TO ALLOW FOR VERTICAL LIVE LOAD DEFLECTIONS OF SPAN/360 AT FLOOR FRAMING OR SPAN/240 AT ROOF FRAMING. DO NOT MAKE RIGID VERTICAL AND
HORIZONTAL CONNECTIONS TO THE PRIMARY STRUCTURE IN THE PLANE OF THE PARTITION.
5) SUBMITTALS AND SUBSTITUTIONS:
5A) SUBMITTALS: REFER TO SPECIFICATIONS FOR DETAILED REQUIREMENTS.
- IF THE CONTRACTOR REQUESTS A CHANGE FROM THE STRUCTURAL DRAWINGS, IT SHALL BE APPROVED BY THE ARCHITECT AND DESIGNED BY MARTIN/MARTIN, INC. PRIOR TO SUBMITTING SHOP DRAWINGS.
VARIATION SHALL BE INDICATED ON THE SHOP DRAWINGS. CONTRACTOR SHALL COMPENSATE
MARTIN/MARTIN, INC. FOR MAKING THE CHANGE.
- CONSTRUCTION DOCUMENTS SHALL NOT BE REPRODUCED FOR USE IN SUBMITTALS
- ALL SHOP DRAWINGS SHALL REFERENCE THE STRUCTURAL DRAWING NUMBER AND DETAIL USED TO
PREPARE THE SUBMITTAL
- SUBMIT A STATEMENT OF RESPONSIBILITY FOR CONSTRUCTION OF THE LATERAL LOAD RESISTING SYSTEM
IDENTIFIED IN THE DESIGN CRITERIA IN ACCORDANCE WITH IBC 2021 SECTION 1704
5B) SUBSTITUTIONS: ARCHITECT’S APPROVAL SHALL BE SECURED FOR ALL SUBSTITUTIONS
5C)NONCONFORMANCE: NOTIFY ARCHITECT OF CONDITIONS NOT CONSTRUCTED PER THE CONTRACT DOCUMENTS PRIOR TO PROCEEDING WITH CORRECTIVE WORK. SUBMIT PROPOSED REPAIR TO THE ARCHITECT FOR ACCEPTANCE. CONTRACTOR SHALL COMPENSATE MARTIN/MARTIN, INC. FOR DESIGNING THE
REPAIR.
5D)ALL SHOP DRAWINGS SHALL BE SUBMITTED IN ELECTRONIC FORMAT ONLY.
6) TEMPORARY CONDITIONS, CONSTRUCTION ENGINEERING, AND OSHA STANDARDS:
6A) THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION AND ONLY FOR LOADS
ANTICIPATED DURING THE STRUCTURE’S SERVICE LIFE.
6B) THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR’S CONSTRUCTION METHODS AND/OR SEQUENCES. REFER TO “LATERAL LOAD RESISTING SYSTEM DESCRIPTION” IN DESIGN CRITERIA FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL PROVIDE ALL REQUIRED ENGINEERING AND OTHER MEASURES TO ACHIEVE THE MEANS, METHODS, AND SEQUENCES OF WORK WHICH MAY INCLUDE, BUT
IS NOT LIMITED TO:
- LAYOUT
- DESIGN FOR FORMWORK, SHORING, AND RESHORING
- DESIGN OF CONCRETE MIXES
- ERECTION PROCEDURES WHICH ADDRESS STABILITY OF THE FRAME DURING CONSTRUCTION
- WELD PROCEDURES
- DESIGN OF TEMPORARY BRACING OF WALLS FOR WIND, SEISMIC, OR SOIL LOADS
- SURVEYING TO VERIFY CONSTRUCTION TOLERANCES
- EVALUATION OF TEMPORARY CONSTRUCTION LOADS ON STRUCTURE DUE TO EQUIPMENT AND
MATERIALS
- STRUCTURAL ENGINEERING TO RESIST ANY OTHER LOADS NOT IDENTIFIED ON DESIGN DRAWINGS
6C)CONTRACTOR’S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND
CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE
CONSTRUCTION PERIOD.
6D)FOUNDATION WALLS SHALL NOT BE BACKFILLED UNTIL THE SLABS-ON-GRADE AND UPPER SLABS ARE IN-PLACE AND REACH FULL STRENGTH UNLESS ADEQUATE BRACING IS PROVIDED. USE ONLY
HAND OPERATED TOOLS FOR COMPACTION ADJACENT TO FOUNDATION WALLS AND GRADE BEAMS.
GRADE BEAMS SHALL BE BACKFILLED EVENLY ON BOTH SIDES.
6E) NOTHING SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE CONSTRUED AS ELIMINATING THE NEED FOR THE CONTRACTOR TO COMPLY WITH ALL OSHA REQUIREMENTS. WHERE THE STRUCTURAL
DRAWINGS APPEAR TO CONFLICT WITH OSHA REQUIREMENTS, THE STRUCTURAL DRAWINGS
REPRESENT FINAL CONDITIONS ONLY.
- THE CONTRACTOR SHALL ADD ALL ERECTION FRAMING NECESSARY TO COMPLY WITH OSHA.
- THE CONTRACTOR SHALL ADD ALL NECESSARY BOLTS, ANCHOR BOLTS, PLATES, STABILIZER
PLATES, BRIDGING, BRACING, ETC., AS WELL AS CLOSURES FOR OPENINGS.
GENERAL NOTES
HALF SIZE DRAWINGS
SCALES SHOWN ARE FOR FULL
SIZE (22" X 34") DRAWINGS
Sheet List
Sheet Number Sheet Name
S0.0 GENERAL NOTES
S0.1 GENERAL NOTES
S0.2 GENERAL NOTES
S0.3 QUALITY ASSURANCE
S0.4 QUALITY ASSURANCE
S1.0 LOADING DIAGRAMS
S1.1 FOUNDATION PLAN
S1.2 ROOF FRAMING PLAN
S2.0 TYPICAL CONCRETE DETAILS
S2.1 TYPICAL CONCRETE DETAILS
S2.2 CONCRETE DETAILS
S3.0 TYPICAL WOOD DETAILS
S3.1 WOOD DETAILS
S3.2 WOOD DETAILS
S3.3 WOOD DETAILS
S3.4 WOOD DETAILS
S3.5 WOOD DETAILS
NO. REVISION/ ISSUE DATE
100%
CONSTRUCTION
DOCUMENTS
05/22/2024
10/15/2024
1'-5"
F ORE S T S ERV I CE
DEP
A R TMENT OF AGR I CU LT
UR
E
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
M M
J O
B
P
R
IN
C
IP
A L:
E O
R
P R
O
JE
C T
M A
N A
G E
R
D E
S
IG
N E
R S
LE
A D
R E
V
IT
T E
C H
D
A T
E P
R
IN
T E
D
F
IL
E P
A T
H
/1
/2
:2 0:
P M
A u to d e sk
D o cs
/U S
F S
B uf fa lo
C re e k
W o rk C e n te r/
3.
.S
.0
B uf fa lo
C re e k
W or k C e n te r
A d d iti o n s
S
3.
rv t
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
GENERAL NOTES
S0.1 10/15/2024
SMOLLOY
JAJA
23.1414.S.01
JE
R
E M
Y A
JA
JE
R
E M
Y A
JA
S E
A N
M O
LL
O
Y
.1
4.
S
.0
S E
A N
M O
LL
O
Y N
/A
ROOF MECHANICAL
UNITS -- -- NO -- SEE PLAN
FIRE PREVENTION
BAY/EXERCISE ROOM -- 150 NO -- 2000
OFFICE LOBBIES, EXIT
FACILITIES -- 100 NO -- 2000
ROOF 25 (INCLUDES 8
SOLAR
READY/ROOFING
LOAD)
20 ROOF LIVE
LOAD, SEE NOTE 7
FOR SNOW LOADS
NO -- 300
LOCATION
SUPERIMPOSED
DEAD LOAD (PSF)
LIVE LOAD (PSF)
LIVE LOAD
REDUCTION
PARTITION LOAD
(PSF)
POINT LOAD (LB)
GRAVITY LOADS
1) CODES AND STANDARDS:
1A)GENERAL DESIGN
- INTERNATIONAL BUILDING CODE 2021
2) SEISMIC LOADS
- SEISMIC DESIGN CATEGORY = B
- RISK CATEGORY = II
- EARTHQUAKE IMPORTANCE FACTOR, le = 1.00
- MAPPED SPECTRAL RESPONSE ACCELERATION, Ss = 26.1 %g
- MAPPED SPECTRAL RESPONSE ACCELERATION, S1 = 6.50 %g
- DESIGN SPECTRAL RESPONSE COEFFICIENT, SDs = 0.277
- DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 = 0.104
- SOIL SITE CLASS = D
- STRUCTURAL SEISMIC LATERAL SYSTEM: LIGHT FRAME WALLS WITH STRUCTURAL WOOD SHEAR PANELS
- RESPONSE MODIFICATION FACTOR, R = 6.5
- SEISMIC RESPONSE COEFFICIENT, Cs = 0.043
- SYSTEM OVERSTRENGTH FACTOR, OMEGA = 2.5
- DESIGN BASE SHEAR = 15.0k
- SEISMIC ANALYSIS PROCEDURE: EQUIVALENT LATERAL-FORCE ANALYSIS
3) WIND LOADS
- RISK CATEGORY = II
- BASIC ULTIMATE WIND SPEED, Vult = 145 mph
- BASIC NOMINAL WIND SPEED, Vasd = 113 mph
- EXPOSURE CATEGORY = C
- INTERNAL PRESSURE COEFFICIENT, Gcpi = +/-0.18
- TOPOGRAPHIC FACTOR, Kzt = 1.000
- GROUND ELEVATION FACTOR, Ke = 1.0000
4) DESIGN WIND PRESSURE FOR COMPONENTS AND CLADDING AND ELEMENTS DESIGNED BY THE CONTRACTOR 4A) LISTED COMPONENT AND CLADDING WIND PRESSURES ARE INCLUDED FOR REFERENCE ONLY. FINAL
CALCULATIONS SHALL BE COMPLETED BY CONTRACTOR
4B) PRESSURES LISTED BELOW ARE ULTIMATE
4C)SEE 'WALL CORNER AND SPECIAL ROOF ZONES DIAGRAM'
4D)COMPONENT AND CLADDING SURFACE PRESSURES (PSF)
- WALLS PRESSURES
WALLS AREA 10 SF 100 SF 200 SF 500 SF
WALLS INTERIOR NEG ZONE 4 -39.6 -34.1 -32.5 -30.3
WALLS CORNER NEG ZONE 5 -48.9 -37.9 -34.7 -30.3
WALLS POSITIVE ZONES 4 & 5 36.5 31.0 29.4 27.2
- ROOF PRESSURES
ROOF AREA 10 SF 100 SF 500 SF
NEGATIVE ZONE 1 -67.4 -21.0 -21.0
NEGATIVE ZONE 2 -98.3 -54.1 -36.5
NEGATIVE ZONE 3 -116.9 -61.2 -31.2
POSITIVE ALL ZONES 22.1 16.0 16.0
OVERHANG ZONE 1' -77.3 -46.4 -46.4
OVERHANG ZONE 2 -108.2 -75.1 -61.9
OVERHANG ZONE 3 -145.4 -71.1 -71.1
5) LATERAL LOAD RESISTING SYSTEM DESCRIPTION:
- WOOD PANEL SHEATHED HORIZONTAL DIAPHRAGMS, WOOD PANEL SHEATHED SHEAR WALLS, CAST-IN-PLACE
CONCRETE FOUNDATION WALLS
6) GRAVITY LOADS
6A) SEE GRAVITY LOADS TABLE SEE LOAD KEY SHEETS FOR SUPERIMPOSED DEAD LOAD AND LIVE LOADS USED IN
DESIGN
6B)DRIFTING, SLIDING AND UNBALANCED SNOW
- GROUND SNOW LOAD = 52.9 psf
- SNOW EXPOSURE FACTOR, Ce = 1.0
- SNOW LOAD IMPORTANCE FACTOR, ls = 1.0
- THERMAL FACTOR, Ct = 1.0 (OFFICE ADDITION)
- THERMAL FACTOR, Ct = 1.20 (EXISTING BUILDING AND ENGINE BAY ADDITION)
- UNIFORM ROOF SNOW LOAD = 37.0 psf (OFFICE ADDITION)
- UNIFORM ROOF SNOW LOAD = 44.5 psf (EXISTING BUILDING AND ENGINE BAY ADDITION)
7) RAIN LOADS:
7A) DESIGN RAIN INTENSITY = 2.50 inches per hour
1) GENERAL:
1A) THE FOLLOWING PORTIONS OF THE STRUCTURAL DESIGN WILL NOT BE SUBMITTED AT THE TIME OF PERMIT APPLICATION. WHEN RECEIVED AND REVIEWED, THESE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE BUILDING OFFICIAL BY THE
CONTRACTOR:
- METAL PLATE CONNECTED WOOD TRUSSES
- ANCHORAGE, BRACING AND ATTACHMENT OF REQUIRED ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, FIRE SPRINKLER, AND OTHER EQUIPMENT AND SYSTEMS.
1B) CONNECTION OF DEFERRED SUBMITTAL ITEMS TO PRIMARY STRUCTURE BY DEFERRED SUBMITTAL SUPPLIER. DEFERRED SUBMITTAL SUPPLIER TO PROVIDE CONNECTIONS AND FRAMING ARRANGEMENT TO AVOID LOADING WHICH EXCEEDS THE CAPACITY OF THE ELEMENT BEING ATTACHED TO. REFERENCE LOAD MAPS FOR MECHANICAL, ELECTRICAL, PLUMBING AND FIRE SPRINKLER LOAD
ALLOWANCES.
1C)ALL DEFERRED SUBMITTALS TO BE ATTACHED TO PRIMARY STRUCTURE WITH A PINNED CONNECTION. MOMENT CONNECTIONS TO PRIMARY STRUCTURE NOT PERMITTED UNLESS NOTED ON DRAWINGS OR APPROVED BY ENGINEER IN WRITING PRIOR TO SUBMITTAL
OF DRAWINGS OR CALCULATIONS.
1D)LOADING AND LOCATION FOR ATTACHMENT OF DEFERRED SUBMITTAL ITEMS ARE NOTED ON DRAWINGS AND ARE NOT TO BE RE-
LOCATED OR INCREASED WITHOUT WRITTEN APPROVAL.
1E)WALLS, GRADE BEAMS AND THE UNDERSIDE OF CONCRETE ON METAL DECK SHALL BE CONSIDERED CRACKED FOR THE PURPOSE
OF DESIGNING ANCHORS FOR ATTACHMENT OF DEFERRED SUBMITTAL ITEMS.
1F) SUBMIT STAMPED STRUCTURAL CALCULATIONS FOR ALL DEFERRED SUBMITTAL ITEMS PRIOR TO OR CONCURRENTLY WITH DRAWINGS OR PRODUCT DATA. INCLUDE ANALYSIS OF ATTACHMENT TO PRIMARY STRUCTURE. INCLUDE CURRENT ICC REPORT WITH
ALL PROPRIETARY STRUCTURAL ELEMENTS AND ANCHORS/FASTENERS.
1G)POWDER ACTUATED FASTENERS (PAF) INTO CONCRETE SHALL NOT BE USED TO RESIST TENSION LOADS. POWDER ACTUATED FASTENERS SHALL NOT BE USED TO RESIST GRAVITY LOADS WHICH INCLUDE STONE/BRICK VENEER.
1) DESIGN CRITERIA:
THE GEOTECHNICAL REPORT PREPARED BY YEH AND ASSOCIATES, INC., NUMBER 223-371, DATED 2/28/2024
PROVIDED CRITERIA FOR THE FOUNDATION DESIGN FOR THE PROJECT.
2) FOOTINGS:
2A) FOOTING DESIGN CRITERIA:
- MAXIMUM TOTAL LOAD BEARING PRESSURE = 2750 PSF
- MINIMUM CONTINUOUS FOOTING WIDTH = 1.5 FT
- MINIMUM SPREAD FOOTING WIDTH = 2 FT
- ULTIMATE COEFFICIENT OF FRICTION TO RESIST LATERAL LOADS = 0.35
- FROST DEPTH TO BOTTOM OF FOUNDATION = 36 IN
1) PERSONNEL REQUIREMENTS:
1A) THE CONTRACTOR SHALL ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE ONSITE INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. SUBMIT DOCUMENTED CONFIRMATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL ANCHORS HAVE
PASSED THE TRAINING COURSE PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.
1B) PERSONNEL WHO WILL INSTALL HORIZONTAL OR UPWARDLY INCLINED ADHESIVE ANCHORS IN CONCRETE THAT SUPPORT SUSTAINED TENSION LOADS SHALL BE CERTIFIED BY THE ACI/CRSI ADHESIVE ANCHOR INSTALLER CERTIFICATION PROGRAM. THESE ANCHORS ARE DESIGNATED WITH A (CERT) AFTER THE ANCHOR CALL OUT. SUBMIT DOCUMENTED CONFIRMATION THAT PERSONNEL HAVE PASSED THE
TRAINING COURSE PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.
2) INSTALLATION REQUIREMENTS:
2A) ALL POST-INSTALLED ANCHORS SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S PRINTED
INSTALLATION INSTRUCTIONS AND PER MANUFACTURER'S ON-SITE TRAINING.
2B) ALL ADHESIVE ANCHORS AND ADHESIVE ANCHORED REINFORCEMENT DESIGNS ARE FOR INSTALLATION IN THE FOLLOWING CONDITIONS, UNLESS NOTED OTHERWISE. WRITTEN APPROVAL MUST BE RECEIVED
FROM ENGINEER PRIOR TO INSTALLATION IN ALTERNATE CONDITIONS.
- DRY CONCRETE, UNLESS NOTED OTHERWISE.
- CONCRETE TEMPERATURE AT TIME OF INSTALLATION THROUGH CURE TIME MUST BE WITHIN THE TEMPERATURE RANGE SPECIFIED IN MANUFACTURER'S PRINTED INSTALLATION INSTRUCTION FOR
ADHESIVE GEL AND CURE TIMES.
- ANCHOR HOLES TO BE HAMMER DRILLED AND CLEANED.
- CONCRETE MUST BE AT LEAST 21 DAYS OLD BEFORE INSTALLATION OF ANCHORS.
- HOLES TO BE CLEANED AND PREPARED IN STRICT ACCORDANCE WITH MANUFACTURER'S PRINTED
INSTALLATION INSTRUCTIONS AND EVALUATION REPORT PRIOR TO ADHESIVE INJECTION.
2C)THE POSITION OF EXISTING REINFORCING BARS IN THE CONCRETE STRUCTURE SHALL BE LOCATED PRIOR TO INSTALLING POST INSTALLED ANCHORS OR REINFORCEMENT. EXISTING REINFORCEMENT SHALL BE LOCATED USING A SCANNER, GPR, X-RAY, CHIPPING OR OTHER MEANS. DO NOT DAMAGE OR CUT
EXISTING REINFORCEMENT.
3) SUBSTITUTION REQUESTS:
3A) SUBSTITUTION REQUESTS FOR ALTERNATE PRODUCTS MUST BE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER PRIOR TO USE. CONTRACTOR SHALL PROVIDE CALCULATIONS AND PRODUCT DATA DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS IN COMPLIANCE WITH THE RELEVANT BUILDING CODES, LOAD RESISTANCE, INSTALLATION CATEGORY, CREEP APPROVAL, IN-SERVICE TEMPERATURE AND
INSTALLATION TEMPERATURE OF THE SPECIFIED PRODUCT.
DESIGN CRITERIADEFERRED SUBMITTALS
STEEL NOTES
POST-INSTALLED ANCHOR NOTES
SCREW ANCHORS
HILTI KWIK HUS-EZ - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
EXPANSION ANCHORS
(IN CONCRETE) HILTI KWIK BOLT TZ2 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ADHESIVE ANCHOR RODS
MIN
MIN
THREADED ROD,
UNGREASED
ADHESIVE
(IN CONCRETE W/>12" EMBEDMENT) HILTI HIT-RE 500 V3 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ADHESIVE
(IN CONCRETE) HILTI HIT-HY 200 V3 - -
SUBMIT CALCULATIONS
FOR SUBSTITUTIONS
ANCHOR TYPE PRODUCT
Fy
(KSI)
Fu
(KSI)
COMMENT
POST-INSTALLED ANCHOR TABLE - HILTI
FOUNDATION NOTES
1) CONNECTIONS:
1A) PROVIDE CONNECTIONS AS SHOWN IN THE ‘STEEL BEAM CONNECTION SCHEDULES’ AND DETAILS HEREIN. REFER TO
SPECIFICATION FOR ALTERNATIVES AND CONNECTIONS NOT SHOWN.
2) STEEL MATERIALS:
2A) SEE ‘STEEL MATERIAL TABLE’
3) WELDING REQUIREMENTS:
3A)WELDERS: HAVE IN POSSESSION CURRENT EVIDENCE OF PASSING THE APPROPRIATE AWS. QUALIFICATION TESTS.
3B)MINIMUM WELDS: AISC SPECIFICATION, NOT LESS THAN 3/16” FILLET, CONTINUOUS UNLESS OTHERWISE NOTED.
3C)WELD SIZES AND LENGTHS CALLED FOR ON THE DRAWINGS ARE THE NET EFFECTIVE REQUIRED. INCREASE WELD SIZE IF GAPS
EXIST AT THE FAYING SURFACE.
3D)WELD SIZES SHALL BE AS SHOWN UNLESS A GREATER SIZE IS REQUIRED BY ANSI/AISC 360-05 TABLES J2.3 AND J2.4.
3E) ALL GROOVE WELDS SHALL BE COMPLETE PENETRATION UNLESS NOTED.
3F) FIELD WELDING SYMBOLS INDICATE SEQUENCE CONSIDERED DURING DESIGN. THE CONTRACTOR SHALL REQUEST APPROVAL FROM THE ENGINEER TO MODIFY WELD INSTALLATION LOCATION INDICATED ON THE DOCUMENTS:
- FROM SHOP TO FIELD
- FROM FIELD TO SHOP
3G)DEFORMED ANCHOR STUDS (DAS) AND HEADED ANCHOR STUDS (HAS / HDAS) SHALL BE SHOP OR FIELD WELDED AT
CONTRACTOR’S OPTION UNLESS NOTED OTHERWISE
4) STRUCTURAL STEEL INSTALLATION:
4A) UNLESS INDICATED OTHERWISE, SNUG TIGHTEN ALL JOINTS AS DEFINED BY AISC
CONNECTIONS AS INDICATED BELOW SHALL BE PRETENSIONED PER TABLE J3.1 OF ANSI/AISC 360-10 AISC 360-10 AISC 360-05 AISC 360-16
WF, WT A992 50 65 EC: 1.35 / RC: 75% -
WELDING ELECTRODES,
THICKNESS OF THINNER
PART > 0.1 INCHES (12 GA)
E70 - - - PER AWS
RECT HSS A500 GR C 50 62 EC: 2.20 / RC: 50% -
PLATES A572 50 65 EC: 1.90 / RC: 50% -
CHANNELS AND OTHER
SHAPES A572 50 65
EC: 1.35 / RC: 50%
UNO
ANGLE RC: 75%
BOLTS
F3125 - TYPE A325
OR F1852
- 120 -
BOLTS ARE 3/4"Ø UNO, USE
TENSION- CONTROLLED
WHERE POSSIBLE
ANCHOR RODS AND
THROUGH BOLTS F1554 GR 55 55 75 -
WELDABLE, HEAVY HEX
HEADED
STEEL ELEMENT ASTM/TYPE
Fy
(KSI)
Fu
(KSI)
SUSTAINABILITY
GOALS - NOTE 1
COMMENTS
STEEL MATERIAL TABLE
HALF SIZE DRAWINGS
SCALES SHOWN ARE FOR FULL
SIZE (22" X 34") DRAWINGS
NO. REVISION/ ISSUE DATE
100%
CONSTRUCTION
DOCUMENTS
05/22/2024
A R TMENT OF AGR I CU LT
UR
E
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
M M
J O
B
P
R
IN
C
IP
A L:
E O
R
P R
O
JE
C T
M A
N A
G E
R
D E
S
IG
N E
R S
LE
A D
R E
V
IT
T E
C H
D
A T
E P
R
IN
T E
D
F
IL
E P
A T
H
/1
/2
:2 0:
P M
A u to d e sk
D o cs
/U S
F S
B uf fa lo
C re e k
W o rk C e n te r/
3.
.S
.0
B uf fa lo
C re e k
W or k C e n te r
A d d iti o n s
S
3.
rv t
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
GENERAL NOTES
S0.2 10/15/2024
SMOLLOY
JAJA
23.1414.S.01
JE
R
E M
Y A
JA
JE
R
E M
Y A
JA
S E
A N
M O
LL
O
Y
.1
4.
S
.0
S E
A N
M O
LL
O
Y N
/A
1) GENERAL:
1A) ALL WORK SHALL CONFORM WITH ACI 301-10, UNLESS NOTED OTHERWISE IN DRAWINGS OR PROJECT
SPECIFICATIONS.
1B) DETAIL BARS IN ACCORDANCE WITH THE DRAWINGS, PROJECT SPECIFICATIONS, AND ACI PUBLICATION SP-66
(2004): “ACI DETAILING MANUAL”
2) REINFORCING MATERIALS:
2A) SEE ‘REINFORCING MATERIAL TABLE’
3) REINFORCING FABRICATION:
3A) SPLICES:
- NO SPLICING OF REINFORCEMENT PERMITTED EXCEPT AS NOTED ON DRAWINGS. MAKE BARS CONTINUOUS AROUND CORNERS WHERE DETAIL NOT PROVIDED. WHERE PERMITTED, SPLICES MAY BE MADE BY CONTACT LAPS
OR MECHANICAL CONNECTORS.
- SEE ‘LAP SPLICE SCHEDULE’ FOR LAP LENGTHS.
- SPLICE CONTINUOUS TOP AND BOTTOM BARS IN WALLS, BEAMS, AND GRADE BEAMS ‘LTS’ UNLESS NOTED
OTHERWISE.
- SPLICE TOP BARS AT MIDSPAN AND BOTTOM BARS OVER SUPPORT UNLESS NOTED OTHERWISE.
3B)MISCELLANEOUS REINFORCING REQUIREMENTS:
- PROVIDE ADDITIONAL BARS OR STIRRUPS REQUIRED TO SECURE REINFORCING IN PLACE DURING CONCRETE
PLACEMENT.
- MAKE ALL REINFORCING BAR BENDS IN THE FABRICATOR’S SHOP UNLESS NOTED.
- NO WELDING OF REINFORCING PERMITTED UNLESS NOTED ON DRAWINGS. WHERE PERMITTED, PERFORM
WELDING IN ACCORDANCE WITH AWS D1.4-2011.
- PROVIDE ADDED REINFORCING TO TRIM ALL OPENINGS, NOTCHES, AND REENTRANT CORNERS AS NOTED IN
TYPICAL DETAILS.
4) STRUCTURAL CONCRETE MIX REQUIREMENTS:
4A) SEE ‘CONCRETE MIX TABLE’
5) SLAB-ON-GRADE:
5A) VERIFY ALKALINITY OF CONCRETE SURFACE, SLAB VAPOR TRANSMISSION, AND SLAB FLATNESS/LEVELNESS
ARE COMPATIBLE WITH FLOORING SYSTEM AND ADHESIVES PRIOR TO INSTALLING FLOORING.
5B) TAKE PRECAUTIONS TO MINIMIZE SLAB CURLING. GRIND SLAB OR USE LEVELING COMPOUND IF FLOOR
FLATNESS AND LEVELNESS VALUES ARE NOT ACCEPTABLE TO THE ARCHITECT.
6) NON-SHRINK GROUT:
6A) CONFORM TO ASTM C1107
6B) ACHIEVE 6000 PSI COMPRESSIVE STRENGTH AT 28 DAYS.
7) PLACING REINFORCEMENT:
7A) REINFORCEMENT PROTECTION:
- SEE ‘REBAR COVER TABLE’
- SEE ACI 117-10 FOR REINFORCEMENT PLACING TOLERANCES
7B) PROVIDE ACCESSORIES NECESSARY TO PROPERLY SUPPORT REINFORCING AND WELDED WIRE REINFORCEMENT AT POSITIONS SHOWN ON PLANS. ALL REINFORCING, DOWELS, BOLTS, AND EMBEDDED PLATES SHALL BE SET AND TIED IN PLACE BEFORE THE CONCRETE IS POURED. “STABBING” INTO PREVIOUSLY PLACED
CONCRETE IS NOT PERMITTED.
8) CONSTRUCTION/CONTROL JOINTS:
8A) SUBMIT DRAWINGS SHOWING CONSTRUCTION AND CONTROL JOINT LOCATIONS ALONG WITH THE SEQUENCE OF POURS. CONSTRUCTION JOINT LOCATIONS AND CASTING SEQUENCE SHALL BE ARRANGED TO MINIMIZE THE
EFFECTS OF ELASTIC AND LONG-TERM SHORTENING/SHRINKAGE.
8B) CONCRETE CONSTRUCTION JOINT SURFACE SHALL BE CLEANED AND ALL LAITANCE AND LOOSE MATERIAL
REMOVED PRIOR TO SECOND CONCRETE PLACEMENT.
9) MODIFICATIONS TO HARDENED OR EXISTING CONCRETE
9A) UNLESS NOTED ON THE STRUCTURAL DOCUMENTS MODIFICATIONS AS LISTED BELOW SHALL NOT BE MADE TO
HARDENED OR EXISTING CONCRETE WITHOUT APPROVAL OF THE ARCHITECT:
- SAW CUTTING
- CORING
- CHIPPING
9B)DO NOT CUT OR DAMAGE ANY REINFORCING WITHOUT APPROVAL OF THE ARCHITECT
10) SLEEVES, OPENINGS, AND EMBEDED PIPE/CONDUITS:
10A) GENERAL
- REFER TO TYPICAL DETAILS FOR REQUIREMENTS FOR CONDUIT AND PIPE EMBEDDED IN WALLS AND SLABS
- REFER TO TYPICAL DETAILS FOR SPACING AND LAYOUT LIMITATIONS FOR SLEEVES AND OPENINGS
- FORM OPENINGS AND PROVIDE SLEEVES BEFORE PLACING CONCRETE, CORING OF CONCRETE IS NOT
PERMITTED
- AT COMPOSITE SLABS DO NOT CUT DECK FOR AT LEAST 7 DAYS AFTER CONCRETE PLACEMENT
10B) REINFORCING
- REFER TO TYPICAL DETAILS FOR REINFORCEMENT REQUIREMENTS AT SLEEVES, OPENINGS OR CONDUIT
- DO NOT CUT REINFORCING WHICH MAY CONFLICT
CONCRETE NOTES
a. WHERE AIR CONTENT IS INDICATED IN THE MIX TABLE, PROVIDE AIR ENTRAINING ADMIXTURE. TOTAL AIR
CONTENT LIMITS INCLUDE BOTH ENTRAINED AND ENTRAPPED AIR +/- 1 1/2%.
FOR CONCRETE PLACED BY PUMPING PROVIDE CONCRETE MIX FLOWABILITY TO FACILITATE PUMPING. ENTRAINED AIR MAY BE USED TO FACILITATE PUMPING SUBJECT TO THE PROVISIONS OF NOTE b BELOW.
USE TYPE I / II PORTLAND CEMENT UNLESS NOTED OTHERWISE. FOR CONCRETE MIXES USED ON FLOORS MINIMUM
CEMENTITIOUS CONTENT SHALL BE 540 POUNDS PER CUBIC YARD
- PROVIDE WORKABILITY AND CONSISTENCY TO PERMIT CONCRETE TO BE WORKED READILY INTO FORMS AND AROUND REINFORCEMENT UNDER CONDITIONS OF PLACEMENT TO BE EMPLOYED, WITHOUT SEGREGATION OR EXCESSIVE BLEEDING. CONTRACTOR SHALL SELECT APPROPRIATE SLUMP. USE ADMIXTURES AS REQUIRED TO
OBTAIN DESIRED RESULTS.
- PROVIDE THE MINIMUM COMPRESSIVE STRENGTH AS INDICATED IN THE MIX TABLE. DO NOT EXCEED THE
MAXIMUM WATER-CEMENT RATIO NOTED.
PROPORTIONS OF MATERIALS IN CONCRETE MIX SHALL BE ESTABLISHED TO:
CONCRETE MIX TABLE NOTES:
ALL CONC OTHERWISE
NOT SPECIFIED 4 NWC 0.50 3/4 6 -
WORK CENTER SLAB ON
GRADE
3.5 NWC - 1 NP -
2 FOOTINGS 3 NWC - 1 - -
ALL CONC EXPOSED TO
WEATHER OR DEICERS:
ENGINE BAY SLAB ON
GRADE, WALLS, COLUMNS
5 NWC 0.40 3/4 6 -
CONC
MIX
TYPE
INTENDED USE
28 DAY
STRENGTH f'c
(KSI)
CONC
WEIGHT
MAX W/C
RATIO,
INCLUDING
FLY ASH
MAX
AGGREGATE
SIZE, IN
(ASTM C33)
TOTAL AIR
CONTENT
NOTE a
OTHER
REQTS,
NOTE b
CONCRETE MIX TABLE
EPOXY COATING OF REINFORCING A775 OR A934 - - -
WELDED WIRE REINFORCING, DEFORMED A1064 70 80 -
WELDED WIRE REINFORCING, SMOOTH A1064 65 75 -
WELDED & FIELD BENT REINF A706 60 80 -
TYP REINFORCING A615 60 90 -
REINF ELEMENT ASTM Fy (KSI) Fu (KSI) COMMENTS
REINFORCING MATERIAL TABLE
1) LAMINATED MEMBER SIZES:
1A) LVL, PSL, LSL, GLU-LAM AND OTHER FABRICATED MEMBERS (TJI) SIZES SHOWN ARE NET. OTHER
MEMBER SIZES ARE NOMINAL.
2) FRAMING LUMBER:
2A) DRY (19% MAXIMUM MOISTURE CONTENT AT THE TIME OF INSTALLATION), HEM-FIR WITH MINIMUM DESIGN VALUES BASED ON THE 2018 NDS. SEE ‘FRAMING LUMBER TABLE’ FOR MINIMUM GRADES. DOUGLAS
FIR-LARCH WHERE NOTED ON PLAN.
2B) BEAMS AND STRINGERS USED WITH CANTILEVERS OR CONTINUOUS SPANS SHALL BE GRADED TO
PROVIDE THE SPECIFIED ALLOWABLE STRESSES OVER THE ENTIRE MEMBER LENGTH.
3) FABRICATED LUMBER:
3A) FABRICATED LUMBER DESIGNATIONS ARE THOSE MANUFACTURED BY iLEVEL, BOISE, IDAHO.
3B) FABRICATED LUMBER IS DESIGNATED ON THE DRAWINGS AS ONE OF THE FOLLOWING: TJI JOISTS, MICROLLAM (LVL), PARALLAM (PSL), TIMBERSTRAND (LSL).
3C)THE MANUFACTURER SHALL PROVIDE WEB STIFFENERS ON I-JOISTS, END BLOCKING, BRIDGING, AND ERECTION BRACING AS REQUIRED. SEE “DESIGN CRITERIA” FOR DESIGN DEAD AND LIVE LOADS.
3D)FABRICATED LUMBER SHALL BE DRY.
3E) SEE ‘FABRICATED LUMBER TABLE’ FOR MINIMUM PROPERTIES (AT NORMAL LOAD DURATIONS).
3F) FABRICATED RIMBOARD SHALL BE LAMINATED STRAND LUMBER.
4) SHEATHING:
4A)WOOD STRUCTURAL PANELS (WSP)
- WOOD STRUCTURAL PANELS SHALL BE APA RATED SHEATHING CONFORMING TO U.S. DEPARTMENT OF
COMMERCE STANDARD PS 2-10.
- ALL WOOD PANELS SHALL BE EXPOSURE 1.
5) BLOCKING AND BRIDGING:
5A) PROVIDE 1” X 4” SIMPSON NC/NCA CROSS-BRIDGING AT 8’ O.C. MAXIMUM SPACING FOR ALL SOLID SAWN WOOD JOISTS AND RAFTERS. PROVIDE FULL HEIGHT SOLID BLOCKING (MINIMUM WIDTH TO MATCH WIDTH OF FRAMING) BETWEEN ALL FRAMING MEMBERS (SOLID SAWN JOISTS AND RAFTERS, FABRICATED JOISTS
AND RAFTERS AND TRUSSES) AT SUPPORTS.
6) NAILING:
6A) UNLESS NOTED OTHERWISE ON THE DRAWINGS, PROVIDE COMMON NAILS WITH SIZES SHOWN IN THE TABLE BELOW. MINIMUM NAILING SHALL BE IN ACCORDANCE WITH THE TYPICAL WOOD CONNECTION
SCHEDULE AND IBC 2021 TABLE 2304.10.2
6B)WHERE COMMON NAILS ARE SPECIFIED, BOX NAILS OF EQUAL LENGTH MAY BE SUBSTITUTED PROVIDED
ONE BOX NAIL IS ADDED FOR EVERY THREE COMMON NAILS SPECIFIED.
7) METAL CONNECTORS:
7A) FRAMING CONNECTORS SHALL CONFORM TO IBC 2021 SECTION 2303.5 FRAMING CONNECTOR
DESIGNATIONS ARE THOSE MANUFACTURED BY SIMPSON STRONG-TIE COMPANY, SAN LEANDRO,
CALIFORNIA. OTHER MANUFACTURER’S PRODUCTS MAY BE USED IF APPROVED BY THE ENGINEER.
FURNISH NAILS AND/OR BOLTS OF DIAMETER, LENGTH, AND NUMBER SPECIFIED BY THE MANUFACTURER
FOR EACH CONNECTOR.
7B) ALL CONNECTOR HOLES SHALL BE FILLED WITH PROPER NAILS/BOLTS INCLUDING OPTIONAL NAIL LOCATIONS FOR UPLIFT. ALL BOLT HOLES SHALL BE DRILLED INTO FRAMING MEMBERS. MAXIMUM HOLE
DIAMETER IS 1/16” LARGER THAN THE BOLT DIAMETER.
8) OPENINGS:
8A) OPENING, POCKETS, ETC., SHALL NOT BE PLACED IN BEAMS, JOISTS, RAFTERS, STUDS, POSTS, COLUMNS, TIMBER AND OTHER STRUCTURAL MEMBERS UNLESS DETAILED ON THE STRUCTURAL
DRAWINGS.
WOOD NOTES
ALL OTHER NO. 1 975 150 1,500,000
DECKING SELECT DX 1,600 - 1,500,000
EXPOSED FRAMING NO. 1 975 150 1,500,000
POSTS & TIMBER NO. 1 975 140 1,300,000
BEAMS & STRINGERS NO. 1 1,050 140 1,300,000
ROOF JOIST & RAFTERS NO. 2 850 150 1,300,000
FLOOR-JOIST NO. 2 850 150 1,300,000
NON-LOAD BEARING STUDS STUD 675 150 1,200,000
LOAD BEARING STUDS (AND COLUMNS
ASSEMBLED FROM STUDS) NO. 2 850 150 1,300,000
EXTERIOR STUDS NO. 2 850 150 1,300,000
TYPE OF USE GRADE Fb (PSI) Fv (PSI) E (PSI)
FRAMING LUMBER SCHEDULE - HEM-FIR (HF)
3. PSL = 2.0E PARALLAM PSL (WIDTH = 5 1/4")
2. LVL = 2.0E MICROLLAM LVL (WIDTH = 1 3/4")
1. FABRICATED LUMBER DESIGNATIONS ARE THOSE MANUFAFCTURED BY WEYERHAUSER.
NOTES:
11 7/8" PSL 11 7/8" BEAM 29,855 12,055 1,466 9,844
11 7/8" LVL 11 7/8" BEAM 8,925 3,950 488 2,480 -
11 1/4" LVL 11 1/4" BEAM 8,070 3,740 416 2,480 -
9 1/2" LVL 9 1/2" BEAM 5,885 3,160 250 2,480 -
5 1/2" LVL 5 1/2" BEAM 2,125 1,830 48 2,480 -
11 7/8" TJI-560 11 7/8" I-JOIST 9,500 2,050 636 1,725 WEB STIFF REQD
11 7/8" TJI-360 11 7/8" I-JOIST 6,180 1,705 419 1,505 WEB STIFF REQD
11 7/8" TJI-210 11 7/8" I-JOIST 3,795 1,655 315 1,460 WEB STIFF REQD
PRODUCT DEPTH TYPE
MR
(FT-LBS)
VR
(LBS)
EI (x10^6
IN^2-LBS)
3 1/2" END
REACTION
(LBS)
REMARKS
FABRICATED LUMBER TABLE
HALF SIZE DRAWINGS
SCALES SHOWN ARE FOR FULL
SIZE (22" X 34") DRAWINGS
NO. REVISION/ ISSUE DATE
100%
CONSTRUCTION
DOCUMENTS
05/22/2024
ALL OTHER NO. 1 1,000 180 1,700,000
EXPOSED FRAMING NO. 1 1,000 180 1,700,000
POSTS & TIMBER NO. 1 1,200 170 1,600,000
BEAMS & STRINGERS NO. 1 1,350 170 1,600,000
TYPE OF USE GRADE Fb (PSI) Fv (PSI) E (PSI)
FRAMING LUMBER SCHEDULE - DOUGLAS FIR-LARCH (DF-L)
A R TMENT OF AGR I CU LT
UR
E
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
M M
J O
B
P
R
IN
C
IP
A L:
E O
R
P R
O
JE
C T
M A
N A
G E
R
D E
S
IG
N E
R S
LE
A D
R E
V
IT
T E
C H
D
A T
E P
R
IN
T E
D
F
IL
E P
A T
H
/1
/2
:2 0:
P M
A u to d e sk
D o cs
/U S
F S
B uf fa lo
C re e k
W o rk C e n te r/
3.
.S
.0
B uf fa lo
C re e k
W or k C e n te r
A d d iti o n s
S
3.
rv t
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
QUALITY
ASSURANCE
S0.3 10/15/2024
SMOLLOY
JAJA
23.1414.S.01
JE
R
E M
Y A
JA
JE
R
E M
Y A
JA
S E
A N
M O
LL
O
Y
.1
4.
S
.0
S E
A N
M O
LL
O
Y N
/A
- FIELD GLUING
STRUCTURAL WOOD
C - -
- PERMANENT BRACING
P -
VERIFY INSTALLATION IN CONFORMANCE TO
APPROVED SUBMITTAL
- CONNECTIONS
P -
VERIFY SIZE, LOCATION, TIGHTNESS, AND
PROPER INSTALLATION OF METAL PLATES,
BOLTS, NAILS, HOLD-DOWNS AND ALL OTHER
CONNECTORS OR OTHER DEVICES
METAL PLATE CONNECTED WOOD TRUSSES
- MANUFACTURED WOOD
CONNECTORS AND JOIST
HANGERS
P ICC-ES REPORT
VERIFY TYPE, ALL CONNECTOR HOLES FILLED
WITH PROPER FASTENERS, AND INSTALLATION
IN CONFORMANCE WITH ICC-ES REPORT
- FASTENER
P -
VERIFY TYPE, DIAMETER, LENGTH, SPACING,
EDGE DISTANCES, AND USE OF WASHERS.
VERIFY HOLE DIAMETER FOR BOLTS
CONNECTIONS
- ATTACHMENT
P -
VERIFY PANEL SHEATHING BOUNDARY, PANEL
EDGE, AND FIELD FASTENERS AND
ATTACHMENT AT ALL EDGES OF DIAPHRAGM
- PANEL SHEATHING
P -
VERIFY TYPE, THICKNESS, PANEL SIZE AND
ORIENTATION
SHEATHED DIAPHRAGM
- HOLD-DOWN
P -
VERIFY TYPE, SIZE, LOCATION, FASTENERS,
AND ANCHORAGE
- ATTACHMENT
P -
VERIFY PANEL SHEATHING BOUNDARY, PANEL
EDGE, AND FIELD FASTENERS AND
ATTACHMENT AT ALL EDGES OF SHEAR WALL
- PANEL SHEATHING P - VERIFY TYPE AND THICKNESS
SHEATHED SHEAR WALL
- FLOOR/ROOF FRAMING
P -
VERIFY FRAMING IS ALIGNED OVER A BEARING
STUD WITHIN PERMITTED DIMENSION
- SPLICING
P -
NO SPLICING OF STRUCTURAL MEMBERS
PERMITTED UNLESS SPECIFIED ON THE
CONSTRUCTION DOCUMENTS
- FIELD CUTS AND
NOTCHES P -
NO CUTS OR NOTCHES PERMITTED UNLESS
SPECIFIED ON THE CONSTRUCTION
DOCUMENTS
- BRIDGING AND BLOCKING P - VERIFY INSTALLATION AND LOCATION
- MEMBERS AND
CONNECTIONS P -
VERIFY SPECIES, GRADE, SIZE, LOCATION,
SPACING, END BEARING AND END ATTACHMENT
FRAMING
ITEM FREQUENCY STANDARD CRITERIA
WOOD SPECIAL INSPECTIONS
STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TESTING
QUALITY ASSURANCE GENERAL NOTES
1) GENERAL:
1A) SCOPE OF WORK
- THE CONTRACTOR WILL ENGAGE A QUALIFIED INSPECTION AND TESTING AGENCY(S), TO PERFORM SPECIAL INSPECTIONS AND TESTING FOR ALL STRUCTURAL MEMBERS AND ASSEMBLIES AS NOTED HEREIN.
THE QUALIFIED INSPECTION AND TESTING AGENCY(S) SHALL BE A SEPARATE ENTITY FROM THE
CONTRACTOR.
- SUBMIT DOCUMENTATION OF QUALIFICATIONS, INCLUDING COMPETENCE AND RELEVANT WORK
EXPERIENCE OR TRAINING OF SPECIAL INSPECTORS TO THE GOVERNMENT PRIOR TO THE START OF WORK.
- SPECIAL INSPECTIONS AND TESTING INCLUDE THE ADDITIONAL STRUCTURAL SPECIAL INSPECTION AND
TESTING REQUIREMENTS FOR SEISMIC AND/OR WIND RESISTANCE.
- SPECIAL INSPECTIONS ARE IN ADDITION TO INSPECTIONS BY THE GOVERNMENT REQUIRED BY IBC 2021
SECTION 110.
- REFER TO THE SPECIFICATIONS FOR REPORTING AND PROCEDURAL REQUIREMENTS FOR QUALITY
ASSURANCE AND QUALITY CONTROL.
- REFER TO ARCH/MECH/ELEC/CIVIL SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL SPECIAL
INSPECTION AND TESTING THAT MAY BE REQUIRED.
1B) SPECIAL INSPECTIONS AND TESTING ARE APPLICABLE TO ALL REVISIONS AND/OR FUTURE WORK ADDED
BY AMENDMENTS TO THESE DOCUMENTS.
1C) DEFINITIONS
- SPECIAL INSPECTOR: THE AGENCY ENGAGED BY THE CONTRACTOR AND APPROVED BY THE
GOVERNMENT TO ACT AS THE DESIGNATED REPRESENTATIVE TO PERFORM INSPECTIONS.
- SPECIAL INSPECTION: INSPECTION PERFORMED BY THE SPECIAL INSPECTOR ACCORDING TO IBC 2021 SECTION 1704 TO ENSURE COMPLIANCE WITH APPROVED CONSTRUCTION DOCUMENTS AND REFERENCED
STANDARDS.
- (P) PERIODIC INSPECTION: THE PART-TIME OR INTERMITTENT OBSERVATION BY THE SPECIAL INSPECTOR OF WORK BEING PERFORMED. SPECIAL INSPECTOR SHALL BE PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED. OBSERVATION OF ALL WORK (100% VISUAL) SHALL BE MADE AT THE
COMPLETION OF THE WORK.
- (C) CONTINUOUS INSPECTION: THE FULL-TIME OBSERVATION BY THE SPECIAL INSPECTOR OF WORK BEING PERFORMED. SPECIAL INSPECTOR SHALL BE PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED. OBSERVATION OF ALL WORK (100% VISUAL) SHALL BE MADE AT THE COMPLETION OF THE
WORK.
1D) DEFICIENCIES IN WORK
- CORRECT DEFICIENCIES IN WORK THAT TESTS AND INSPECTIONS INDICATE DO NOT COMPLY WITH THE
CONTRACT DOCUMENTS AND REFERENCED STANDARDS.
- ALL COST OF ADDITIONAL TESTING AND/OR INSPECTIONS FOR CORRECTIVE WORK SHALL BE BORNE BY
THE CONTRACTOR.
2) SHOP FABRICATIONS:
2A) GENERAL
- PERFORM INSPECTIONS AND TESTING FOR ALL SHOP FABRICATED STRUCTURAL MEMBERS AND
ASSEMBLIES AS NOTED HEREIN. SPECIAL INSPECTOR SHALL PERFORM SPECIAL INSPECTIONS AND TESTING UNLESS THE FABRICATOR IS REGISTERED AND APPROVED BY THE GOVERNMENT TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION OR FABRICATION HAS A CURRENT ICC-ES EVALUATION REPORT.
- SPECIAL INSPECTOR SHALL VERIFY THE FABRICATOR MAINTAINS AND FOLLOWS DETAILED SHOP FABRICATION AND QUALITY CONTROL PROCEDURES, UNLESS FABRICATOR IS REGISTERED AND APPROVED.
- AT THE COMPLETION OF FABRICATION, THE APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE AUTHORITY HAVING JURISDICTION ACCORDING TO IBC 2021 SECTION 1704.2.5.1.
- APPROVED FABRICATORS MAY PERFORM TESTING NOTED HEREIN EXCEPT THAT NONDESTRUCTIVE TESTING (NDT) SHALL ONLY BE PERFORMED BY PERSONNEL WITH QUALIFICATIONS THAT MEET OR EXCEED THE CRITERIA OF AWS D1.1 SUBCLAUSE 6.14.6 AND AMERICAN SOCIETY FOR NONDESTRUCTIVE TESTING
(ASNT) SNT-TC-1A OR ASNT CP-189.
2B) SHOP FABRICATIONS INCLUDED
- SHOP FABRICATED STRUCTURAL STEEL INCLUDING STAIRS AND RAILING ELEMENTS
- PRE-FABRICATED WOOD STRUCTURAL ELEMENTS
- SHOP FABRICATED STEEL CONNECTIONS FOR STRUCTURAL WOOD CONNECTIONS
2. SEE CIVIL DRAWINGS AND/OR SPECIFICATIONS FOR CLASSIFICATION AND TESTING REQUIREMENTS FOR
COMPACTED FILL AND/OR CONTROLLED LOW-STRENGTH MATERIAL.
1. SEE CIVIL DRAWINGS AND/OR SPECIFICATIONS FOR ADDITIONAL EARTHWORK AND UTILITY INSPECTION
REQUIREMENTS.
SOILS SPECIAL INSPECTION NOTES:
- PLACEMENT
C -
VERIFY USE OF PROPER MATERIALS,
DENSITIES, COMPACTION, AND LIFT
THICKNESSES
- PRIOR TO PLACEMENT
P -
VERIFY SUBGRADE HAS BEEN PROPERLY
PREPARED
CONTROLLED FILL
- BEARING MATERIAL
P SOILS REPORT
VERIFY BEARING MATERIAL IS ADEQUATE TO
ACHIEVE THE DESIGN BEARING CAPACITY
- EXCAVATION
P -
VERIFY EXCAVATIONS ARE EXTENDED TO THE
PROPER DEPTH AND HAVE REACHED THE
PROPER BEARING MATERIAL
SUBGRADE
ITEM FREQUENCY STANDARD CRITERIA
SOILS SPECIAL INSPECTIONS
- CURE TIME
100% VISUAL -
VERIFY FULL CURE TIME HAS ELAPSED PRIOR
TO APPLICATION OF TORQUE OR LOAD TO
ANCHOR
- AFTER INSTALLATION OF
ATTACHED ASSEMBLY
100% VISUAL -
VERIFY NUMBER, EDGE DISTANCES, AND
ANCHOR FLUSH WITH AND PERPENDICULAR TO
THE RECEIVING SURFACE
- DURING INSTALLATION
OF ANCHOR
C ICC-ES REPORT
CONTINUOUS INSPECTION REQUIRED
REGARDLESS IF PERIODIC INSPECTION IS
PERMITTED BY ICC-ES REPORT. VERIFY HOLE
DIMENSIONS, HOLE CLEANING, ANCHOR
EMBEDMENT, EDGE DISTANCES AND SPACING
- PRIOR TO INSTALLATION
OF ANCHOR
EACH ANCHOR ICC-ES REPORT
VERIFY TYPE, DIAMETER, LENGTH, FINISH, AND
BASE MATERIAL. VERIFY SOLID GROUTED AREA
AROUND ANCHORS IN GROUTED MASONRY
- PRIOR TO START OF
WORK - ICC-ES REPORT
REVIEW CONTRACTOR'S INSTALLATION
PROCEDURE
ADHESIVE ANCHORS, REINFORCING STEEL ANCHORED INTO HARDENED CONCRETE
- AFTER INSTALLATION OF
ATTACHED ASSEMBLY 100% VISUAL -
VERIFY NUMBER, EDGE DISTANCES, AND
ANCHOR FLUSH WITH AND PERPENDICULAR TO
THE RECEIVING SURFACE
- DURING INSTALLATION
OF ANCHOR
C ICC-ES REPORT
CONTINUOUS INSPECTION REQUIRED
REGARDLESS IF PERIODIC INSPECTION IS
PERMITTED BY ICC-ES REPORT. VERIFY HOLE
DIMENSIONS, HOLE CLEANING, ANCHOR
EMBEDMENT, EDGE DISTANCES AND SPACING
- PRIOR TO INSTALLATION
OF ANCHOR
EACH ANCHOR ICC-ES REPORT
VERIFY TYPE, DIAMETER, LENGTH, FINISH, AND
BASE MATERIAL. VERIFY SOLID GROUTED AREA
AROUND ANCHORS IN GROUTED MASONRY.
VERIFY MAXIMUM IMPACT WRENCH TORQUE
RATING FOR SCREW ANCHORS
- PRIOR TO START OF
WORK - ICC-ES REPORT
REVIEW CONTRACTOR'S INSTALLATION
PROCEDURE
EXPANSION ANCHORS, SLEEVE ANCHORS, SCREW ANCHORS
ITEM FREQUENCY STANDARD CRITERIA
POST-INSTALLED ANCHORS/REINFORCING STEEL SPECIAL INSPECTIONS
HALF SIZE DRAWINGS
SCALES SHOWN ARE FOR FULL
SIZE (22" X 34") DRAWINGS
NO. REVISION/ ISSUE DATE
100%
CONSTRUCTION
DOCUMENTS
A R TMENT OF AGR I CU LT
UR
E
SHEET
OF
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.
SUB SHEET NO.
DATE
UNITED STATES
DEPARTMENT OF AGRICULTURE
FOREST SERVICE
R2
SOUTH PLATTE RANGER DISTRICT
M M
J O
B
P
R
IN
C
IP
A L:
E O
R
P R
O
JE
C T
M A
N A
G E
R
D E
S
IG
N E
R S
LE
A D
R E
V
IT
T E
C H
D
A T
E P
R
IN
T E
D
F
IL
E P
A T
H
/1
/2
:2 0:
P M
A u to d e sk
D o cs
/U S
F S
B uf fa lo
C re e k
W o rk C e n te r/
3.
.S
.0
B uf fa lo
C re e k
W or k C e n te r
A d d iti o n s
S
3.
rv t
BUFFALO CREEK WORK
CENTER - OFFICE AND
ENGINE STORAGE
ADDITIONS
PIKE-SAN ISABEL NATIONAL FOREST &
CIMARRON AND COMANCHE NATIONAL
GRASSLANDS
QUALITY
ASSURANCE
S0.4 10/15/2024
SMOLLOY
JAJA
23.1414.S.01
JE
R
E M
Y A
JA
JE
R
E M
Y A
JA
S E
A N
M O
LL
O
Y
.1
4.
S
.0
S E
A N
M O
LL
O
Y N
/A
2. REPORTS OF COMPRESSIVE STRENGTH TESTS SHALL CONTAIN THE FOLLOWING INFORMATION: DATE OF CONCRETE PLACEMENT, LOCATION OF CONCRETE BATCH IN WORK, DESIGN 28-DAY COMPRESSIVE STRENGTH, SLUMP, CONCRETE SUPPLIER AND MIXTURE ID NUMBER, TIME OF BATCH AND PLACEMENT, AMBIENT AIR TEMPERATURE, SITE ADDED WATER AND ADMIXTURES, UNIT WEIGHT, AND AS REQUIRED BY ASTM C39.
1. NONDESTRUCTIVE TESTING MAY BE PERMITTED BY THE ARCHITECT, BUT WILL NOT BE USED AS SOLE BASIS
FOR APPROVAL OR REJECTION OF DEFICIENT CONCRETE.
STRUCTURAL CONCRETE TESTING NOTES:
TEST PER SCHEDULE BELOW FOR 56-DAY
STRENGTH:
- 7 DAYS: (1) 6x12 OR (1) 4x8
- 28 DAYS: (2) 6x12 OR (3) 4x8
- 56 DAYS: (2) 6x12 OR (3) 4x8
- COMPRESSIVE
STRENGTH
EACH
COMPOSITE
SAMPLE
ASTM C31
ASTM C39
EITHER:
(4)6x12 OR (6)4x8
CYLINDERS
TEST PER SCHEDULE BELOW FOR 28-DAY
STRENGTH:
- 7 DAYS: (1) 6x12 OR (1) 4x8
- 28 DAYS: (2) 6x12 OR (3) 4x8
- 56 DAYS: (1) 6x12 OR (2) 4x8 (IF 28 DAY TESTS DO
NOT ACHIEVE SPECIFIED 28 DAY STRENGTH)
ACCEPTANCE CRITERIA PER ACI 318
- COLD WEATHER CURING
- ASTM C1074
RECORD MAXIMUM AND MINIMUM CONCRETE
TEMPERATURE DURING CURING PERIOD, WHEN
DAILY AVERAGE AIR TEMPERATURE OF 40 °F OR
BELOW IS EXPECTED FOR 3 SUCCESSIVE DAYS
DURING CURING PERIOD
-…
This is the start of the file's text. The full file is on GovTribe.