A5 - rev LWS Architectural Set.pdf
PDF 6 MB Posted
- Attached to
- GAOA Lake Winfield Scott Campground (GA)
- Solicitation number
- 12445226Q0003
- Issued by
-
Department of Agriculture Forest Service
About this file
Summary of Lake Winfield Scott Campground Reconstruction Contract Documents
This is a comprehensive set of architectural and engineering design drawings and specifications for the Lake Winfield Scott Campground Reconstruction project (Contract #12445223C0003) located in Union County, Georgia, on the Chattahoochee-Oconee National Forest. The project involves reconstruction of three primary buildings: Building 100 (Entrance Station, 214 square feet), Buildings 200/300 (two identical Campground Bath Houses, 1,111 square feet each), and renovation of a Picnic Pavilion. The work must comply with the 2021 International Building Code, IPC, IMC, NEC, ASHRAE 90.1, and NFPA standards. All work requires permits, inspections, and certificates of occupancy from local authorities; contractors must verify utility locations before excavation and coordinate with other trades to avoid conflicts with structural and mechanical systems.
The project specifications detail requirements across multiple construction disciplines. Plumbing systems include hot water heaters (electric 80-gallon heat pump and 6-gallon units), water-temperature limiting devices for public facilities, soft copper tubing for water distribution, Schedule 40 PVC-DWV for waste piping, floor drains, wall hydrants, and drinking fountains with bottle fillers. HVAC systems feature ductless heat pump units (Mitsubishi), wall heaters (Stiebel Eltron 1.5 kW units), exhaust and intake fans, and ductwork with manual dampers. Electrical work includes site lighting, interior/exterior lighting with LED fixtures, dedicated 20-amp circuits for hand dryers and water heaters, fire extinguisher cabinets mounted at 48 inches maximum above finished floor, and compliance with seismic bracing requirements. Interior finishes include ceramic tile flooring and wall tile in shower and restroom areas, epoxy flooring in office spaces, gypsum board walls, and T&G wood ceilings and soffits. Exterior construction utilizes stone veneer, cement board siding with battens, standing seam metal roofing, and fiber-reinforced panel doors. All work must be coordinated with project team members including the USDA Forest Service, architect (Johnson, Laschober & Associates, P.C.), and various engineering consultants.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Amendment 4- 12445226Q0003.pdf | ||
| A1- rev3 RFQ T and C.docx | DOCX document | |
| Amend3 LWS Campground Recon.xlsx | XLSX spreadsheet | |
| Amendment 3- 12445226Q0003.pdf | ||
| A3 - Rev SOI LWS Mar2026.pdf | ||
| A1 - rev2 RFQ T and C.docx | DOCX document | |
| Amendment 0002 - 12445226Q0003.pdf | ||
| Questions 12445226Q0006.docx | DOCX document | |
| A2 - Rev SOW LWS Feb2026.docx | DOCX document | |
| A3 - Rev SOI LWS Feb2026.pdf | ||
| A1 - rev2 RFQ T and C.docx | DOCX document | |
| Amendment 0001 - 12445226Q0003.pdf | ||
| A1 - rev RFQ Terms and Conditions 12445226Q0003.docx | DOCX document | |
| A1 -RFQ Terms and Conditions 12445226Q0003.docx | DOCX document | |
| A2 - Rev SOW LWS Final.docx | DOCX document | |
| A3 - SOI.pdf | ||
| A5 - LWS Architectural Set.pdf | ||
| A7 - LWS CIVIL_100_R1_signed-final.zip | ZIP file | |
| A8 - Info SR 180 at Slaughter Crk.docx | DOCX document | |
| A9 - WD GA20250107 Bldg Union County.pdf | ||
| A4 - Updated Combined SPECS.pdf | ||
| A6 - Past Performance Questionnaire.pdf |
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
THE GENERAL CONTRACTOR AND HIS SUB-CONTRACTORS SHALL BE REQUIRED TO VISIT THE
PREMISES TO INSPECT EXISTING CONDITIONS, BECOME FAMILIAR WITH LOCAL CONDITIONS
UNDER WHICH THE WORK IS TO BE PERFORMED AND CORRELATE PERSONAL OBSERVATIONS
WITH REQUIREMENTS OF THE DRAWINGS.
ALL WORK PERFORMED SHALL BE IN STRICT COMPLIANCE WITH COUNTY REGULATIONS AND
CODES, O.S.H.A. STANDARDS, THE CODE STANDARDS LISTED, EXECUTED IN ACCORDANCE
WITH ACCEPTED INDUSTRY STANDARDS, AND CONFORM TO SPECIFIC REGULATIONS AS
MANDATED BY THE OWNER AND THE ARCHITECT.
IT SHALL BE THE GENERAL CONTRACTOR'S RESPONSIBILITY TO INSURE THE PROCUREMENT
OF ALL REQUIRED AND NECESSARY PERMITS. ALL CONTRACTORS SHALL OBTAIN
NECESSARY AND APPLICABLE, CITY/COUNTY PERMITS, INSPECTIONS AND APPROVAL PRIOR
TO THE COMMENCEMENT OF ANY WORK AND CERTIFICATE OF OCCUPANCY UPON
COMPLETION OF PROJECT. CONTRACTOR SHALL FURNISH COPIES OF PERMITS, INSPECTIONS
AND CERTIFICATES TO OWNER UPON REQUEST.
CONTRACTOR SHALL BE REQUIRED TO COORDINATE WORK SCHEDULE TO MINIMIZE
DISRUPTION OF NORMAL ACTIVITIES AND TO AVOID INTERFERENCE WITH ADJACENT
OPERATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR TAKING ADEQUATE
PRECAUTIONS TO PROTECT SURROUNDINGS, MATERIALS AND EXISTING FINISHES
THROUGHOUT ALL PHASES OF CONSTRUCTION AREAS AND OCCUPIED OR PUBLIC AREAS TO
BE MAINTAINED BY CONTRACTOR. DAMAGE TO EXISTING-TO-REMAIN CONSTRUCTION,
MATERIALS OR EQUIPMENT TO BE RESTORED TO ORIGINAL CONDITION.
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF TRASH AND DEBRIS FROM JOB SITE
ON A DAILY BASIS. FINAL CLEAN-UP WITHIN SCOPE OF WORK:
GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF ALL RELATED
TRADES AND VENDORS NECESSARY TO THE COMPLETION OF THE JOB ON A TIMELY BASIS.
DO NOT SCALE DRAWINGS. USE WRITTEN DIMENSIONS ONLY. SUBMIT TO ARCHITECT ANY
DISCREPANCIES FOR CLARIFICATION
ALL WORK SHALL BE IN COMPLIANCE WITH THE INTERNATIONAL BUILDING CODE, GENERAL
CONDITIONS OF THE CONTRACT FOR CONSTRUCTION, CURRENT EDITION OF NATIONAL
ELECTRIC CODE, INTERNATIONAL PLUMBING, AND MECHANICAL CODE, RECOGNIZED
INDUSTRY STANDARDS, CRAFTSMANSHIP STANDARDS IN THE AREA, ALL MANUFACTURERS
RECOMMENDATIONS, AND ALL OTHER APPLICABLE CODES.
THE DESIGN PROFESSIONAL DOES NOT GUARANTEE THE PERFORMANCE OF THE PROJECT IN
ANY RESPECT OTHER THAN THAT OUR PROFESSIONAL WORK AND JUDGEMENT RENDERED
MEET THE STANDARDS OF CARE OF OUR PROFESSION.
THE LOCATION OF THE EXISTING UTILITIES AND STRUCTURES SHOWN HEREON ARE
APPROXIMATE. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY THE
EXISTENCE AND ACTUAL LOCATION OF SUCH, WHETHER SHOWN HEREON OR NOT, PRIOR TO
ANY EXCAVATION ANY DAMAGES SHALL BE REPAIRED AT THE EXPENSE OF THE
CONTRACTOR.
THE FLOOR ON BOTH SIDES OF A DOOR SHALL BE LEVEL AND SHALL HAVE THE SAME
ELEVATION ON BOTH SIDES OF THE DOOR, FOR A DISTANCE ON EACH SIDE EQUAL TO THE
WIDTH OF THE WIDEST SINGLE DOOR.
FIRE EXTINGUISHERS SHALL BE LOCATED PER THE REQUIREMENTS OF NFPA 10. THE SIZE
SHALL BE A MINIMUM OF 2A-10BC AND SHALL BE INSTALLED AT A MAXIMUM OF 48" A.F.F. TO
THE TOP OF THE HANDLE.
PROVIDE CONT. SOLID BLOCKING, AS REQUIRED, IN WALLS TO RECEIVE ACCESSORY ITEMS
INCLUDING BUT NOT LIMITED TO THE FOLLOWING:
HANDRAILS
TOILET ROOM ACCESSORIES
GRAB BARS
FIRE EXTINGUISHER CABINETS & BRACKETS
CABINETS AND SHELVES
CLEAN WALLS, DOORS, DOOR FRAMES, HANDRAILS, GUARDRAILS, ETC. PER
MANUFACTURERS RECOMMENDATIONS PRIOR TO SEALING AND PAINTING.
REFER TO THE STRUCTURAL DRAWINGS FOR INFORMATION ON CONSTRUCTION AND
CONTROL JOINTS IN CONCRETE SLABS AND CONCRETE AND MASONRY WALLS. SLAB JOINTS
ARE SPECIFIED AND LOCATED ON THE STRUCTURAL DRAWINGS.
TEMPORARY SIGNS: PROVIDE SIGNS AS REQUIRED TO INFORM PUBLIC AND INDIVIDUALS
SEEKING ENTRANCE TO PROJECT.
PROVIDE TEMPORARY, DIRECTIONAL SIGNS FOR CONSTRUCTION PERSONNEL AND VISITORS.
MAINTAIN AND TOUCH UP SIGNS SO THEY ARE LEGIBLE AT ALL TIMES.
SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION AND DIRECTIONS.
OWNER
OWNER'S REP/ 24 HOUR CONTACT
ARCHITECT
MECHANICAL ENGINEER
STRUCTURAL ENGINEER
JOHNSON, LASCHOBER AND ASSOCIATES, P.C.
MARK LORAH, P.E.
1296 BROAD STREET
AUGUSTA, GEORGIA 30901
PHONE: 706-724-5756
EMAIL: mlorah@thejlagroup.com
USDA FOREST SERVICE REGION 8
TRAVIS HEMINGWAY, E.I.T., FACILITIES ENGINEER
1755 CLEVELAND HIGHWAY
GAINESVILLE, GA 30501
PHONE(Gov't cell): (803) 508-0180 EMAIL: travis.hemingway@usda.gov
JOHNSON, LASCHOBER AND ASSOCIATES, P.C.
MICHAEL N. BOOKER, P.E.
1296 BROAD STREET
AUGUSTA, GEORGIA 30901
PHONE: 706-724-5756
EMAIL: cwilliamson@thejlagroup.com
JOHNSON, LASCHOBER AND ASSOCIATES, P.C.
HERBERT W. GILLIAM, P.E.
701 EAST BAY STREET, SUITE 304
CHARLESTON, SC 29403
PHONE: 843-619-4656
EMAIL: hgilliam@theJLAgroup.com
JOHNSON, LASCHOBER AND ASSOCIATES, P.C.
WATSON LEE DORN III, NCARB, AIA
1296 BROAD STREET
AUGUSTA, GEORGIA 30901
PHONE: 706-724-5756
EMAIL: ldorn@thejlagroup.com
CIVIL ENGINEER
JOHNSON, LASCHOBER AND ASSOCIATES, P.C.
WILL BUCHANAN, P.E.
1296 BROAD STREET
AUGUSTA, GEORGIA 30901
PHONE: 706-724-5756
EMAIL: wbuchanan@thejlagroup.com
ELECTRICAL ENGINEER
JOHNSON, LASCHOBER AND ASSOCIATES, P.C.
JOSEPH PEARSON, P.E.
1296 BROAD STREET
AUGUSTA, GEORGIA 30901
PHONE: 706-724-5756
EMAIL: jpearson@thejlagroup.com
BLUE RIDGE RANGER DISTRICT
STEVERSON MOFFAT
2042 HIGHWAY 515 WEST
BLAIRSVILLE, GA 30512
PHONE: (706) 745-7494
EMAIL: steverson.moffat@usda.gov
WALL TYPE
TYPICAL DIMENSION INDICATOR
DETAIL/PLAN KEY SECTION KEYS
DIRECTION OF
SECTION
INTERIOR ELEVATION KEY
REVISION INDICATION
REVISION NUMBER
AREA REVISED
DOOR NUMBER
WINDOW TYPE
DRAWING NAME
ENLARGED DETAIL INDICATOR DIRECTION OF SECTION
TERMINATION OF SECTION
DETAIL LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
BUILDING SECTION
LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF SECTION
WALL SECTION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF SECTION
DETAIL LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
COLUMN GRID REFERENCE
TERMINATION OF SECTION
DRAWING SCALE
DRAWING LOCATION ON SHEET GRID
A
1 View Name
SCALE: 1/8" = 1'-0"A101
A1 A-101
SIM
A1
A-101
SIM
A1
A-101
SIM
A1 A-101
SIM
01_FLOOR
12'-0"
CENTERLINE
9 1/2"
FLOOR ELEVATION
ROOM NAME AND AREA
A
ELEVATION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF ELEVATION
DIRECTION OF ELEVATION
A-8011
ROOM NAME
150 SF
1i
A-201 A1
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
BUILDING ELEVATION KEY
ELEVATION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF ELEVATION
DIRECTION OF ELEVATION
A-4011
SEE DOOR SCHEDULE
6" 8'
-0
4'-0"
GENERAL CONTRACTOR:
PROJECT:
3" 3"
2' -4
3"
2' -1
0" 2'
-4
1 1/2" HIGH ARIAL TEXT (BLACK)
PROJECT TEXT TO MATCH
OWNER/BUILDER PREFERENCE
3" WIDE BORDER AROUND
PERIMETER OF SIGN
JLA IMAGE w/ BORDER
1 1/2" HIGH ARIAL TEXT (BLACK)
CONTRACTOR NAME AND LOGO-
STYLE AND COLORS AS REQUIRED
4x4 SUPPORT POST TO EXTEND 2'-0"
BELOW GRADE
GRADE
ARCHITECT/ENGINEER:
1 1/2" HIGH ARIAL TEXT (BLACK)
3"
UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE
GEORGIA UNION COUNTY SOUTHERN REGION
CHATTAHOOCHEE - OCONEE NATIONAL FOREST
LAKE WINFIELD SCOTT
CAMPGROUND RECONSTRUCTION
INDEX OF DRAWINGS
PROJECT TEAM
PROJECT LOCATION MAPGENERAL NOTES:
GRAPHIC SYMBOLS
JOBSITE SIGN
CONTRACT #12445223C0003
REVIEWED BY:
FOREST ENGINEER/FACILITIES PROGRAM MANAGER:
DATE:
PROJECT MANAGER:
DATE:
FOREST ENGINEERING STAFF OFFICER:
DATE:
DISTRICT RANGER:
DATE:
REGIONAL FACILITIES PROGRAM MANAGER:
DATE:
RECOMMENDED BY:
FOREST SUPERVISOR:
DATE:
R8 DIRECTOR OF ENGINEERING:
DATE:
APPROVED BY:
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/1 /20
:31 :27
P M
C:
\R
EV
IT
- L oc al Pr oje cts
\30
_L ak e W inf iel d S co tt\3
1_
Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
G-001
EH
CTH
WLD
3094.2301
08/30/24
COVER SHEET
G-001 COVER SHEET
G-002 BUILDING INFORMATION / CODE ANALYSIS
ARCHITECTURAL
A-101 BUILDING 100 - ENTRANCE STATION - FLOOR PLAN, LIFE SAFETY PLAN,
REFLECTED CEILING PLAN & ROOF PLAN
A-102 BUILDING 100 - ENTRANCE STATION - EXTERIOR ELEVATIONS AND
BUILDING SECTIONS
A-201 BUILDINGS 200/300 - CAMPGROUND BATH HOUSE - FLOOR PLAN
A-202 BUILDINGS 200/300 - CAMPGROUND BATH HOUSE - REFLECTED CEILING
PLAN & ROOF PLAN
A-203 BUILDINGS 200/300 - CAMPGROUND BATH HOUSE - EXTERIOR
ELEVATIONS
A-204 BUILDINGS 200/300 - CAMPGROUND BATH HOUSE - BUILDING SECTIONS
A-301 PICNIC PAVILION - ROOF PLAN & DETAILS
A-601 WALL TYPES, WALL SECTIONS & DETAILS
A-602 ROOF DETAILS
A-801 DOOR, WINDOW SCHEDULE, DETAILS
A-901 INTERIOR FINISH SCHEDULE, SPECIFICATIONS, ELEVATIONS
A-902 TOILET ACCESSORIES, TOILET FIXTURES, MOUNTING HEIGHTS,
CASEWORK SECTION
A-903 MISCELLANEOUS DETAILS
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-101 BUILDING 100 - ENTRANCE STATION - FOUNDATION AND SLAB PLAN &
ROOF FRAMING PLAN
S-201 BUILDINGS 200/300 - CAMPGROUND BATH HOUSE - FOUNDATION AND
SLAB PLAN & ROOF FRAMING PLAN
S-301 CONCRETE SECTIONS AND DETAILS
S-401 MASONRY AND WOOD SECTIONS AND DETAILS
S-101-P PICNIC PAVILION FOUNDATION PLAN
S-201-P PICNIC PAVILION ROOF FRAMING PLAN
S-202-P PICNIC PAVILION ELEVATIONS AND SECTIONS
S-203-P PICNIC PAVILION ELEVATIONS AND SECTIONS
S-204-P PICNIC PAVILION ELEVATIONS AND SECTIONS
PLUMBING
P-001 PLUMBING GENERAL NOTES AND LEGEND
P-101 BUILDING 100 ENTRANCE STATION PLUMBING PLANS
P-201 BUILDINGS 200/300 CAMPGROUND BATH HOUSE PLUMBING PLANS
P-301 PLUMBING SCHEDULES
P-401 PLUMBING DETAILS
MECHANICAL
M-001 HVAC GENERAL NOTES & LEGEND
M-101 BUILDING 100 ENTRANCE STATION - HVAC PLAN
M-201 BUILDINGS 200/300 CAMPGROUND BATH HOUSE - HVAC PLAN
M-301 HVAC SCHEDULES
M-401 HVAC DETAILS
ELECTRICAL
E-001 ELECTRICAL NOTES AND SYMBOLS
ES001 ELECTRICAL SITE PLAN SHEET 1 OF 4
ES002 ELECTRICAL SITE PLAN SHEET 2 OF 4
ES003 ELECTRICAL SITE PLAN SHEET 3 OF 4
ES004 ELECTRICAL SITE PLAN SHEET 4 OF 4
E-101 BUILDING 100 - ENTRANCE STATION - LIGHTING AND POWER PLANS
E-102 BUILDING 200/300 - CAMPGROUND BATH HOUSE - LIGHTING AND POWER
PLANS
E-601 ELECTRICAL SCHEDULES AND DETAILS
E-602 ELECTRICAL PANEL SCHEDULES
PROJECT LOCATION
REISSUED FINAL CD 08/30/24
BRADLEY ASHER
Digitally signed by BRADLEY
ASHER
Date: 2025.08.11 21:40:43 -04'00'
2025.08.07 16:49:50 -04'00'
DAVID CULP Digitally signed by DAVID CULP Date: 2025.08.08 08:08:40 -04'00'
Digitally signed by STEVERSON
MOFFAT
Date: 2025.08.07 10:06:05 -04'00'
JOHN CAMPBELL
Digitally signed by JOHN
CAMPBELL
Date: 2025.08.04 13:24:38 -04'00'
TRAVIS
HEMINGWAY
Digitally signed by TRAVIS
HEMINGWAY
Date: 2025.08.04 10:59:16 -04'00'
2021 EDITION
2021 EDITION
2021 EDITION
2021 EDITION
2020 EDITION
2021 EDITION
2021 EDITION
U = 100 FT
U = 300 FT
20 FT
COMMON PATH (IBC TABLE 1006.2.1)
TRAVEL DISTANCES
TRAVEL DISTANCE (IBC 1017.2)
DEAD END (IBC 1020.4)
ROOF CONSTRUCTION
***including supporting beams & joists
***including supporting beams & joists
FLOOR CONSTRUCTION
NONBEARING WALLS & PARTITIONS
INTERIORS
BEARING WALLS
EXTERIORS
FIRE RESISTANCE RATING REQUIRED (IBC TABLE 601, 602)
OCCUPANT LOAD (IBC SECT. 1004 & TABLE 1004.5)
OCCUPANCY TYPE (IBC CHAPTER 3)
STRUCTURAL FRAME
***including columns, girders and trusses
HEIGHT ALLOWED
HEIGHT BY DESIGN (Max)
BUILDING HEIGHT (IBC TABLE 504.3 & 504.4)
Top of highest ridge & 1 STORY
IFC - INTERNATIONAL FIRE CODE
IPC - INTERNATIONAL PLUMBING CODE
IMC - INTERNATIONAL MECHANICAL CODE
IFGC - INTERNATIONAL FUEL GAS CODE
NFPA 70 - NATIONAL ELECTRICAL CODE
IBC - INTERNATIONAL BUILDING CODE
NFPA 101 - LIFE SAFETY CODE
16'-6"
TYPE OF CONSTRUCTION (IBC CHAPTER 6)
SPRINKLER REQUIRED (IBC CHAPTER 9, SECTION 903.2) YES XNO
VBIBC
BUILDING FLOOR AREA ALLOWED PER FLOOR (IBC TABLE 506.2)
SPRINKLER PROVIDED: YES NO
IBC HR
IBC HR
IBC HR
IBC HR
IBC HR
INTERIORS
EXTERIORS IBC HR
IBC HR
X
REQUIRED MEANS OF EGRESS
PER IBC 1005.3.2: Opening Width in Inches divided by 0.2 = Opening capacity
EGRESS CAPACITY (MINIMUM 34" PROVIDED): 34 / .2 = 170 OCCUPANTS
CODE ANALYSIS
MINIMUM UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE ADOPTED STANDARD CODES
REVIEW PER DESIGN
LESS THAN 300 OCCUPANTS
CONSTRUCTION NARRATIVE
LAKE WINFIELD SCOTT RECREATION AREA: All architectural construction shall comply with the requirements of the US Forest Service’s Southern Region Design and Constructions Standards for Southern Region Facilities as the governing document for codes and standards, some of which are listed above. This construction phase will provide three (3) new vertical structures constructed in the recreation area as follows: Entrance Station (254 SF) and two (2) Campground Bath Houses (1,111 SF ea.). The Entrance Station will be constructed with wood walls, wood framed roof system and standing seam metal roofing and the Bath Houses will be constructed with CMU walls, wood framed roof systems and standing seam metal roofing.
PER IBC 1006.2.1, NUMBER OF EXITS REQUIRED = 1
PLUMBING FIXTURES
TOILETS:
FOREST SERVICE HANDBOOK - Recreation Site Handbook - Planning & Design of Developed Recreation Sites & Facilities (Per FSH 2309.13 Chapter 10 13.1.5) 1 toilet per 35 PAOT* (* = recommended rule)
South Loop Campground @ 16 sites & Group Site = 105 PAOT / 35 = 3 required* Provided 3 All-Gender Restrooms (* = directed to provide 3 All-Gender Restrooms & 3 All-Gender Showers)
North Loop Campground @ 15 sites = 75 PAOT / 35 = 3 required* Provided 3 All-Gender Restrooms (* = directed to provide 3 All-Gender Restrooms & 3 All-Gender Showers)
LAVATORIES:
South Loop Campground @ 16 sites & Group Site = 105 PAOT = 2 required* Provided 3 All-Gender Restrooms (* = directed by FS to provide 3 All-Gender Restrooms & 3 All-Gender Showers)
North Loop Campground @ 15 sites = 75 PAOT = 1 required* Provided 3 All-Gender Restrooms (* = directed by FS to provide 3 All-Gender Restrooms & 3 All-Gender Showers)
DRINKING FOUNTAIN:
(Per IBC 2902.1 for Assembly - Museum, Lecture Hall, Libraries,...) 1 per 500
South Loop Campground @ 16 sites = 80 PAOT / 500 = 1 required Provided 1 High & 1 Low
North Loop Campground @ 15 sites = 75 PAOT / 500 = 1 required Provided 1 High & 1 Low
SERVICE SINKS:
(Per IBC 2902.1 for Assembly - Museum, Lecture Hall, Libreries,...) 1 per occupied building
South Loop Campground Bath House = 1 required 1 Provided
North Loop Campground Bath House = 1 required 1 Provided
REQUIRED = 0 HR PROVIDED = 0 HRCORRIDOR FIRE-RESISTANCE RATING (IBC TABLE 1020.2)
BIBC
North Bath House
ALLOWED B:
BY DESIGN:
9,000 SF
1,111 SF
B = 40'-0" & 2 STORIES
Locker Room @ 150 gross SF/Occ GROUP B:
1,111 SF/50 = 22 Occ
Campground Bath Houses (North & South)
OCCUPANT LOAD (FSORAG):
NORTH CAMPGROUND:
16 Camp sites @ 5 PAOT = 80 Occupants
BIBC
Entrance Station
VBIBC
ALLOWED B:
BY DESIGN:
9,000 SF
254 SF
Entrance Station
335 SF/150 = 3 Occ
2021 EDITION IEBC - INTERNATIONAL EXISTING BUILDING CODE
2015 EDITION ABAAS - ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
North Bath HouseEntrance Station
150 gross SF/Occ OFFICE (BUSINESS AREA):
SOUTH CAMPGROUND:
15 Camp sites @ 5 PAOT = 75 Occupants
VBIBC
BIBC
South Bath House
ALLOWED B: 9,000 SF
South Bath House
BY DESIGN: 1,111 SF
Group Site @ 25 PAOT = 25 Occupants
BUILDING 300BUILDING 100 BUILDING 200
2019 EDITION ASHRAE 90.1
< ANGLE
C CENTERLINE
C CHANNEL
d PENNY
T PERPENDICULAR
P PLATE
Ø DIAMETER
AFF ABOVE
ABV ABOVE FINISH FLOOR
ACC ACCESS
AP ACCESS PANEL
ACOUS ACOUSTICAL
ACT ACOUSTICAL TILE
ADD ADDENDUM
ADH ADHESIVE
ADJ ADJACENT
ADJT ADJUSTABLE
A/C AIR CONDITIONING
ALT ALTERNATE
AL ALUMINUM
ALUM ALUMINUM
ANC ANCHOR, ANCHORAGE
AB ANCHOR BOLT A
ANOD ANODIZED
APPROX APPROXIMATE
ARCH ARCHITECT (URAL)
ASPH ASPHALT
BACC BATH ACCESSORY
BSMT BASEMENT
BM BEAM
BRG BEARING
BRG PL BEARING PLATE
BEL BELOW
BET BETWEEN
BEV BEVELED
BIT BITUMINOUS
BLK BLOCK
BLKG BLOCKING
BD BOARD
BS BOTH SIDES
BW BOTH WAYS
BOT BOTTOM
BRK BRICK
BLDG BUILDING
BUR BUILT UP ROOFING
L
L
BBD BULLETIN BOARD
CAB CABINET
CPT CARPET (ED)
CB CATCH BASIN
CK CALK (ING) CAULK (ING)
CLG CEILING
CT CERAMIC TILE
CHBD CHALKBOARD
CIRC CIRCUMFERENCE
CO CLEAN OUT
CLR CLEAR (ANCE)
CMU CONCRETE MASONRY UNIT
CNR. BD. CORNER BEAD
CFSSF COLD FORMED STRUCTURAL
STEEL FRAME
CFSSM COLD FORMED STRUCTURAL
STEEL MEMBER
COL COLUMN
COMP COMPRESS (ED) (ION) (IBLE)
CONC CONCRETE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS OR CONTINUE
CONTR CONTRACT (OR)
CJ CONTROL JOINT
CG CORNER GUARD
CORR CORRUGATED
CTR COUNTER
CFL COUNTERFLASHING
CSG. BD. CASING BEAD
CTSK COUNTERSINK
DPR DAMPER
DP DAMPPROOFING
DL DEAD LOAD
DEM DEMOLISH, DEMOLITION
DMT DEMOUNTABLE
DEPR DEPRESSED
DET DETAIL
DIAG DIAGONAL
DIA DIAMETER
DIM DIMENSION
DIV DIVISION
DR DOOR
DA DOUBLE ACTING
DS DOWNSPOUT
D DRAIN
DT DRAIN TILE
DWR DRAWER
DWG DRAWING
DF DRINKING FOUNTAIN
DW DUMBWAITER
EXF EXHAUST FAN
ELEC ELECTRIC (AL)
EWC ELECTRIC WATER COOLER
EL ELEVATION
ELEV ELEVATOR
EMER EMERGENCY
EQ EQUAL
EQUIP EQUIPMENT
EST ESTIMATE
EXH EXHAUST
EXIST EXISTING
EB EXPANSION BOLT
EJ EXPANSION JOINT
EXPD EXPOSED
EXT EXTERIOR
F/CONC FACE OF CONCRETE
F/FIN FACE OF FINISH
F/MAS FACE OF MASONRY
F/STUDS FACE OF STUDS
FFH FACTORY FINISH
FAS FASTEN (ER)
FGL FIBERGLASS
FIN FINISH (ED)
FFL FINISHED FLOOR LINE
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHS FIRE HOSE STATION
FHC FIRE HOSE CABINET
FPRF FIREPROOF FLASH FLASHING
FLSG FLASHING
FHMS FLATHEAD MACHINE SCREW
FHWS FLATHEAD WOOD SCREW
FLX FLEXIBLE
FL FLOOR (ING)
FD FLOOR DRAIN
FLUR FLUORESCENT
FTG FOOTING
FDN FOUNDATION
FR FRAME (D) (ING)
FS FOREST SERVICE
BO FURNISHED BY OTHERS
FUR FURRED (ING)
GA GAGE, GAUGE
GALV GALVANIZED
GB GRAB BAR
GC GENERAL CONTRACTOR
GLA GLASS, GLAZING
GLULAM GLUE LAMINATED WOOD BEAM
GVL GRAVEL
GWB GYPSUM WALL BOARD
GYP. BD. GYPSUM BOARD
HDW HARDWARE
HP HIGH POINT
HTG HEATING
HVAC HEATING/VENTILATING/AIR
-CONDITIONING
HT HEIGHT
HC HOLLOW CORE
HM HOLLOW METAL
HK HOOK (S)
HORIZ HORIZONTAL
HB HOSE BIBB
HWH HOT WATER HEATER
INCL INCLUDE (D) (ING)
ID INSIDE DIAMETER
ILO IN LIEU OF
INSUL INSULATE (D) (ION)
INT INTERIOR
INV INVERT
JC JANITOR'S CLOSET
JT JOINT
KPL KICKPLATE
KIT KITCHEN
KO KNOCKOUT
LAB LABORATORY
LAM LAMINATE (D)
LAV LAVATORY
L LENGTH
LT LIGHT
LL LIVE LOAD
LVR LOUVER
LP LOW POINT
MFR MANUFACTURE (ER)
MAS MASONRY
MO MASONRY OPENING
MAT MATERIAL (S)
MAX MAXIMUM
MECH MECHANIC (AL)
MED MEDIUM
MFL (WALL)
MTL METAL
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MR MOP RECEPTOR
MULL MULLION
NRC NOISE REDUCTION COEFFICIENT
NOM NOMINAL
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OC ON CENTER (S)
OFD OVERFLOW DRAIN
OPNG OPENING
OPP OPPOSITE
OD OUTSIDE DIAMETER
OA OVERALL
OH OPPOSITE HAND
OHD OVERHEAD
PAOT PERSONS AT ONE TIME
PNT PAINT (ED)
PNB PANIC BAR
PTD PAPER TOWEL DISPENSER
PTN PARTITION
PLAM PLASTIC LAMINATE
PL PLATE
PLY. WD. PLYWOOD
PWD PLYWOOD
PT PRESERVATIVE TREATED
PFB PREFABRICATE (D)
PFN PREFINISHED
PM PRESSED METAL
QT QUARRY TILE
RAD RADIUS
REF REFERENCE
REFL REFLECT (ED) (VE) (OR)
RB RESILIENT BASE
RA RETURN AIR
REV REVISION (S) REVISED
R RISER
RD ROOF DRAIN
RDC ROOF DRAIN CONDUCTOR
RFG ROOFING
RM ROOM
RO ROUGH OPENING
SFGL SAFETY GLASS
SCH SCHEDULE
SNT SEALANT
STG SEATING
SEC SECTION
SSK SERVICE SINK
SHTH SHEATHING
SHT SHEET
SIM SIMILAR
SC SOLID CORE
SPK SPEAKER
SPEC SPECIFICATION (S)
SQ SQUARE
SST STAINLESS STEEL
STD STANDARD
STA STATION
STL STEEL
STO STORAGE
SFRT STOREFRONT
SD STORM DRAIN
STRUC STRUCTURAL
SUSP SUSPENDED
SWP STANDARD WEIGHT PIPE
SYM SYMMETRY (ICAL)
TKBD TACKBOARD
TKS TACKSTRIP
TEL TELEPHONE
TV TELEVISION
TERR TERRAZZO
THK THICK (NESS)
THRES THRESHOLD
TPTN TOILET PARTITION
TPD TOILET PAPER DISPENSER
TOL TOLERANCE
T&G TONGUE AND GROOVE
T/CONC TOP OF CONCRETE
T/SLB TOP OF SLAB
T/STL TOP OF STEEL
T/W TOP OF WALL
TLB TOWEL BAR
TLT TOILET
TME TO MATCH EXISTING
T TREAD
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
UNF UNFINISHED
UR URINAL
U/S UNDERSIDE
VPB VAPOR BARRIER
VERT VERTICAL
VIF VERIFY IN FIELD
VIN VINYL
VCT VINYL COMPOSITION TILE
VB VINYL BASE
VT VINYL TILE
VTR VENT THROUGH ROOF
VWF VINYL WALL FABRIC
WSCT WAINSCOT
WC WATER CLOSET
WPF WATERPROOFING
WWM WELDED WIRE MESH
W. WIDTH, WIDE
WIN WINDOW
WGL WIRED GLASS
WMP WIRE MESH PARTITION
W/ WITH
W/O WITHOUT
WD WOOD
WB WOOD BASE
WPT WORKING POINT
BA
SE
LI
N
E O
F
LO
W
ES
T
TE
XT
" M
IN
BA
SE
LI
N
E O
F H
IG
H
ES
T
TE
XT
" M
AX
TEXT
TEXT
9"
SIZE OF CLEAR FLOOR SPACE - NEW BUILDINGS
52 MIN
M
IN
TOE CLEARANCE - ELEVATION
M
IN
6 MAX
KNEE CLEARANCE - ELEVATION
11 MIN
M
IN
8 MIN
M
IN
CLEAR FLOOR SPACE AT WHEELCHAIR DRINKING
FOUNTAINS
0-
-4
M
AX
5-
-4
M
AX
ST
AN
D
IN
G U
SE
C
H
IL
D R
EN
ST
AN
D
IN
G U
SE
AD
U
LT
STANDING USE DRINKING FOUNTAIN SPOUT
HEIGHT AND LOCATION 5'-7" TURNING RADIUS
ø 5'-7"
3'-0"
5'-0"
5' -0
3' -0
1'-0"1'-0"
T-SHAPED TURNING SPACE
8"
8"
8"
8"
8"
8"
8"
8"
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:31 :32
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
G-002
EH
CTH
WLD
3094.2301
08/30/24
BUILDING INFORMATION /
CODE ANALYSIS
SCALE: 1/2" = 1'-0"G-002
1 SIGN LOCATION DETAIL
ABBREVIATIONS
SCALE: 3" = 1'-0"G-002
3 ALL GENDER RESTROOM SIGN
MOUNTING HEIGHTS AND CLEARANCES
DOOR SIGNAGE
SCALE: 3" = 1'-0"G-002
2 ALL GENDER SHOWER SIGNS
SCALE: 3" = 1'-0"G-002
4 ELEC. RM SIGN
HANDICAP ACCESSIBLE HANDICAP ACCESSIBLE
REISSUED FINAL CD 08/30/24
ALL-GENDER
RESTROOM
STORAGE
OFFICE
2' -2
BO
T
'-2
"A
FF
4' -0
" S Q
A-102
A-102
A-1023
A-102
A-102 4
A-102
A-102
103102
EDGE OF FLOOR SLAB/
EDGE OF STUD
ED
G
E O
F
SL
AB
ED
G
E O
F
ST
U D
14'-8"
'-4
6'
-0
7' -1
1" 9'
-5
14'-8"
EDGE OF SLAB
6" 6"
C
AA
B
CONCRETE SLAB -
SEE S-DRAWINGS
9"
9"COLUMN
CENTER LINE
C O
LU
M
N
C
EN
TE
R
LI
N E
7'-2 3/8"H RO
3'-4 1/2"W x
6"
6"
A-902
REFERENCE ELEVATION T/SLAB = 0"-0"
FLOOR DRAIN -
SEE P-DWGS
WH
COLUMN
SEE S-DWGS
NOTE 6
1'-4"
BOT @ 3'-2" AFF
3'-0" W x
4'-0" H RO 1'-4" 1'-4"
BOT @ 3'-2" AFF
3'-0" W x
4'-0" H RO 1'-4"
2' -2
BO
T
3' -2
" A
FF
4' -0
" S Q
A-102
A-102
A-102
A-102
A-102
A.F.F.9'-0"
A.F.F.9'-0"
A.F.F.9'-0"
TYP.
3'-0"
EQ
NOTE 1,
TYP.
TYP.
3'-0"
NOTE 7
NOTE 3
LVR
1'-6" 6'-7"
2' -8
FLAT T&G CEILING
T&G SLOPING
SOFFIT
14 GAUGE PAINTED CARBON STEEL ACCESS
DOOR AS MANUFACTURED BY NYSTROM,
INC. MODEL #: NW-C-24"x30"-F14 WITH
WHITE POWDER COAT (STEEL) FINISH AND
DRYWALL BEAD, OR EQUAL. PROPERLY
PREPARE OPENING TO RECEIVE S.S.
FASTENERS (TAPCON SCREWS) AND
PRODUCE A 24 1/4" x 30 1/4" R.O.
A-102
A-102
A-102
A-102
6" / 1'-0" 6" / 1'-0"
N O
N -V
EN
TE
D R
ID
G
E C
AP
DASHED LINE INDICATES
OUTSIDE EDGE OF STUD
OR BEAM
STANDING SEAM METAL ROOF -
SEE A-602 FOR DETAILS
2' -0
2' -0
2'-0"
18'-8"
'-1
0"
VTR
NOTE 10
F.E.-1
LEGEND
ROOM NAME & NUMBER
- SEE FINISH SCHEDULE
ON A-901
ROOM NAME
FIRE EXTINGUISHER
WITH BRACKET
TAG/TYPE
1i WALL TYPE - SEE A-601
A STOREFRONT/WINDOW
TYPE - SEE A-801
DOOR NUMBER - SEE
DOOR SCHEDULE ON A-801
DIMENSION NOTES
- EXTERIOR DIMENSIONS ARE FROM EDGE OF SLAB / FACE OF
STUD WALL TO EDGE OF SLAB / FACE OF STUD WALL.
- INTERIOR DIMENSIONS ARE FROM FACE OF STUD WALL TO
FACE OF STUD WALL
CEILING LEGEND
RECESSED LIGHT FIXTURE
SEE E-DWGS
HARD CEILING
MOISTURE RESISTANT
GYPSUM BOARD, PAINTED
MECH CASSETTE SYSTEM
SEE MECH DWGS.
T&G WOOD CEILING AND
SOFFIT
MECH EXHAUST FAN
SEE MECH DWGS.
BATT INSULATION /
SOUND BARRIER
NOTES:
A. CEILING HEIGHT IS NOTED ON RCP AND ROOM FINISH SCHEDULE.
B. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR EXACT SIZES AND SPECIFICATIONS OF FIXTURES AND
EQUIPMENT.
C. LIGHT FIXTURES AND MECHANICAL EQUIPMENT ARE LOCATED ON THE REFLECTED CEILING PLAN. ALL
FIXTURES, EQUIPMENT, AND OTHER CEILING ELEMENTS ARE TO BE CENTERED IN GYPSUM CEILING OR SOFFIT UNLESS NOTED OTHERWISE. ALL DIMENSIONS ON THIS SHEET ARE FROM FACE TO FINISH FACE OR CENTER LINE REFERENCE UNLESS NOTED OTHERWISE. CONTRACTOR SHALL CONSULT THE ARCHITECT OF
ANY CONFLICTS PRIOR TO REVISING LOCATIONS.
D. FIELD COORDINATE PLENUM SPACE AS REQUIRED AND NOTIFY ARCHITECT OF ANY VARIATION.
MECH SUPPLY DIFFUSER
SEE MECH DWGS.
4 FT SURFACE MOUNTED
LED LIGHT FIXTURE
EXIT DOOR
34" 170
T.
D
5' -0
A-102
A-102
A-102
A-10259 SF
ALL-GENDER
RESTROOM
38 SF
STORAGE
117 SF
OFFICE
FE-1
LOOSE FURNITURE
SHOWN FOR
COORDINATION - N.I.C.
WOOD STUD WALL
WALL LEGEND
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:32 :17
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-101
EH
CTH
WLD
3094.2301
08/30/24
BUILDING 100 -
ENTRANCE STATION -
FLOOR PLAN, LIFE
SAFETY PLAN,
REFLECTED CEILING
PLAN & ROOF PLAN
SCALE: 1/4" = 1'-0"A-101
2 BUILDING 100 - FLOOR PLAN
SCALE: 1/4" = 1'-0"A-101
3 BUILDING 100 - REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"A-101
4 BUILDING 100 - ROOF PLAN
SCALE: 1/4" = 1'-0"
12 FT.8421.50
N
SCALE: 1/4" = 1'-0"A-101
1 BUILDING 100 - LIFE SAFETY PLAN
NOTES:
1. SEE E-DRAWINGS FOR ELECTRICAL REQUIREMENTS.
2. SEE A-902 FOR TOILET ACCESSORIES & FIXTURES.
3. WALL LOUVER (IN GABLE) - 12" SQ w/BOT @ 10'-9" AFF CENTERED UNDER RIDGE - SEE M-DWGS.
4. SEE CIVIL DRAWINGS FOR EXACT FINISH FLOOR ELEVATION.
5. INSTALL SEALANT AT PERIMETER OF ALL WALL PENETRATIONS. INSTALL SEALANT ALONG TOP &
SIDES OF ALL WALL MOUNTED ITEMS.
6. PHOTOCELL @ 8'-0" AFF. SEE E-DWGS.
7. SEE M-DWGS FOR HVAC REQUIREMENTS.
8. SEE P-DWGS FOR PLUMBING REQUIREMENTS.
9. SEE S-DWGS FOR STRUCTURAL REQUIREMENTS.
10. VENT THROUGH ROOF (VTR) - INSTALL VTR AFTER STANDING SEAM METAL ROOF. COORDINATE
EXACT ROOF PENETRATION LOCATION TO CENTER BETWEEN STANDING SEAMS. SEE 2/A-602.
CEMENT BOARD
TRIM
STANDING SEAM
METAL ROOF - SEE
A-601 & A-602 FOR
DETAILS
CEMENT BOARD &
BATTEN SIDING
STONE CAP (WATER
TABLE)
STONE VENEER
ELECTRIC METER &
DISCONNECT - SEE
E-DWGS.
FASCIA - SEE DETAIL
FINISHED FLOOR
WALL CAP -
SEE M-DWGS.
WALL HYDRANT -
SEE P-DWGS
/3 A-602
HVAC UNIT
SEE M-DWGS
CEMENT BOARD
LAP SIDING
A A
FINISHED FLOOR
8x8 HVY TIMBER COLUMN
W/ WOOD TRIM, STAINED
SLIDING TRANSACTION
WINDOW
ELECTRIC DISCONNECT -
SEE E-DWGS
C
FINISHED FLOOR
PHOTOCELL -
SEE E-DWGS
B
FINISHED FLOOR
3' -0
2"
117 SF
OFFICE
59 SF
ALL-GENDER
RESTROOM
9' -0
A-601
CONCRETE SLAB -
SEE S-DWGS
POROUS
FILL
VAPOR
BARRIER
FRAMING OMITTED (NOT SHOWN)
FOR CLARITY - SEE S-DWGS.
FINISHED FLOOR
SEE
FOR CASEWORK
DETAILS
/4 A-902
CEILING HT.
'-9
59 SF
ALL-GENDER
RESTROOM
102 38 SF
STORAGE
CEMENT BOARD TRIM
NON-VENTED RIDGE
TRIPLE 2x6's
5/8" ZIP SHEATHING
SYSTEM
STANDING SEAM METAL ROOF
R-19 BATT
INSULATION
2'-0"
3' -2
INSULATION SEE -
FASCIA - SEE DETAIL
STONE VENEER
FINISHED FLOOR
9' -1
3/
4"
BEARING HT.
5/8" SIP SHEATHING
SYSTEM
T&G WOOD
SOFFIT, STAINED
/3 A-602
9' -0
DOUBLE TOP PLATE
A-602
/3 A-602
CEILING HT.
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:33 :56
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-102
EH
CTH
WLD
3094.2301
08/30/24
BUILDING 100 -
ENTRANCE STATION -
EXTERIOR ELEVATIONS
AND BUILDING SECTIONS
SCALE: 1/4" = 1'-0"A-102
1 BUILDING 100 - NORTH ELEVATION
SCALE: 1/4" = 1'-0"A-102
2 BUILDING 100 - SOUTH ELEVATION
SCALE: 1/4" = 1'-0"A-102
3 BUILDING 100 - EAST ELEVATION
SCALE: 1/4" = 1'-0"A-102
4 BUILDING 100 - WEST ELEVATION
SCALE: 1/4" = 1'-0"A-102
5 BUILDING 100 - LONGITUDINAL SECTION
SCALE: 1/4" = 1'-0"A-102
6 BUILDING 100 - TRANSVERSE SECTION
GENERAL NOTES:
1. INSTALL PERIMETER SEALANT AROUND ALL WALL
PENETRATIONS.
2. INSTALL SEALANT AT TOP AND SIDES OF ALL
ITEMS MOUNTED TO EXTERIOR WALLS.
3. PAINT ALL CEMENT BOARD PER SPECIFICATION
099130. COLOR TO BE SELECTED BY ENGINEER /
ARCHITECT.
4. SEE NORTH ELEVATION FOR TYPICAL NOTES.
A-203
A-2032
A-203
A-203
6' -8
3'
-0
7' -0
'-0
8'-8" 8'-8" 9'-4"
26'-8"
4'-8"
NOTE 1
3'-4" 5'-4"
NOTE 1
3'-4" 2'-0"
NOTE 1
3'-4" 4'-8"
1'-4"
NOTE 1
3'-4" 6'-0"
NOTE 1
3'-4" 2'-0"
NOTE 1
3'-4" 7'-4"
1'-6" 1'-6" 1'-6"
1'-6 3/8" 5'-2"
6'-8 3/8" 6'-8 3/8" 6'-8 3/8" 3'-4 1/2"
5'-2" 1'-6 3/8"
'-4
N
O
TE
3'
-4
5' -4
N
O
TE
3'
-4
3' -4
56 SF
ALL-GENDER
SHOWER
56 SF
ALL-GENDER
SHOWER
56 SF
ALL-GENDER
SHOWER
30 SF
JANITORIAL
169 SF
MECHANICAL
CHASE
70 SF
ALL-GENDER
RESTROOM
70 SF
ALL-GENDER
RESTROOM
70 SF
ALL-GENDER
RESTROOM
7'-4" 7'-4" 7'-4" 4'-8"
ELECTRICAL
1'-6"
8'-8" 8'-10" 8'-8"
A-204
A-204
206 207 208
203202201
EXTERIOR FACE
OF BUILDING
SLAB & FACE OF
CMU WALL
8"
8"
CEMENT BOARD WRAPPED
6" WOOD COLUMN, TYP.
A-204
A-204
A-204
A-204
N O
TE
1' -4
4'
-0
8' -0
N O
TE
1' -4
8'
-0
8'-8"
NOTE 2
1'-4"
NOTE 2
1'-4" 5'-4"
N O
TE
1' -4
7'
-4
N O
TE
1' -4
3'
-4
N O
TE
1' -4
4'
-0
1'-4"
NOTE 2
1'-4" 7'-4"
NOTE 2
1'-4"
NOTE 2
1'-4" 2'-0"
FE-1
27'-8"
EXTERIOR FACE
OF SLAB
EX
TE
R
IO
R F
AC
E
O F
C M
U W
AL
L
EX
TE
R
IO
R F
AC
E
O F
C M
U W
AL
L
EXTERIOR FACE
OF BUILDING
SLAB & FACE OF
CMU WALL
REFERENCE ELEVATION T/SLAB = 0'-0"
FD - SEE P-
DWGS, (TYP)
COL. SEE
S-DWGS
DRINKING FOUNTAIN -
SEE P-DWGS
NOTE 6
ø 5'-7"
1'-6 3/8" 5'-2"
7'-4"(H) CMU
WALLS w/
SLOPED SOLID
SURFACE TOP,
SEE /3 A-204
'-8
WALL TYPE
TYPICAL DIMENSION INDICATOR
DETAIL/PLAN KEY SECTION KEYS
DIRECTION OF
SECTION
INTERIOR ELEVATION KEY
REVISION INDICATION
REVISION NUMBER
AREA REVISED
DOOR NUMBER
GLASS TYPE
DRAWING NAME
ENLARGED DETAIL INDICATOR DIRECTION OF SECTION
TERMINATION OF SECTION
DETAIL LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
BUILDING SECTION
LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF SECTION
WALL SECTION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF SECTION
DETAIL LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
COLUMN GRID REFERENCE
TERMINATION OF SECTION
DRAWING SCALE
DRAWING LOCATION ON SHEET GRID
A
1 View Name
SCALE: 1/8" = 1'-0"A101
A1 A-101
SIM
A1
A-101
SIM
A1
A-101
SIM
A1 A-101
SIM
01_FLOOR
12'-0"
CENTERLINE
9 1/2"
FLOOR ELEVATION
ROOM NAME AND AREA
A
ELEVATION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF ELEVATION
DIRECTION OF ELEVATION
A-8011
ROOM NAME
150 SF
1i
A-201 A1
SHEET IDENTIFIER FOR
LOCATION OF DETAIL
BUILDING ELEVATION KEY
ELEVATION LOCATION ON SHEET GRID
SHEET IDENTIFIER FOR
LOCATION OF ELEVATION
DIRECTION OF ELEVATION
A-4011
GRAPHICS LEGEND
DIMENSION NOTES
- EXTERIOR DIMENSIONS ARE FROM FACE OF CMU WALL/ EDGE
OF SLAB TO FACE OF CMU WALL/ EDGE OF SLAB.
- EXTERIOR DIMENSIONS ARE FROM FACE OF CMU WALL TO
FACE OF CMU WALL
- INTERIOR DIMENSIONS ARE FROM FACE OF CMU WALL TO
FACE OF CMU WALL
- INTERIOR DIMENSIONS ARE FROM FACE OF CMU WALL/ EDGE
OF SLAB TO FACE OF CMU WALL
8" CMU WALL
WALL LEGEND
8'-8" (H) CMU WALL - EXTEND
WALL TO DECK w/ STUD WALL -
SEE BUILDING SECTIONS
F.E.-1
LEGEND
ROOM NAME & NUMBER
- SEE FINISH SCHEDULE
ON A-901
ROOM NAME
FIRE EXTINGUISHER
WITH BRACKET
TAG/TYPE
1i WALL TYPE - SEE A-601
A STOREFRONT/WINDOW
TYPE - SEE A-801
DOOR NUMBER - SEE
DOOR SCHEDULE ON A-801
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:34 :53
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-201
EH
CTH
WLD
3094.2301
08/30/24
BUILDINGS 200/300 -
CAMPGROUND BATH
HOUSE - FLOOR PLAN
SCALE: 1/4" = 1'-0"A-201
1 BUILDINGS 200/300 - FLOOR PLAN
SCALE: 1/4" = 1'-0"
12 FT.8421.50
NOTES:
1. PERSONNEL DOORS SHALL HAVE A 3'-4 1/2"W x 7'-4 3/8"H M.O.
2. VENTS - 16"W x 8"H M.O. w/BOT @ 8" A.F.F. SEE ELEVATIONS FOR EXTERIOR
WALL LOCATIONS.
3 SEE A-902 FOR TOILET ACCESSORIES & FIXTURES.
4 SEE CIVIL DRAWINGS FOR EXACT FINISH FLOOR ELEVATION.
5. INSTALL SEALANT AT ALL WALL PENETRATIONS.
6. PHOTOCELL MOUNTED @ 9'-0" AFF. SEE E-DWGS.
7. SEE E-DWGS FOR LIGHTING FIXTURES.
8. SEE P-DWGS FOR PLUMBING REQUIREMENTS.
9. SEE S-DWGS FOR STRUCTURAL REQUIREMENTS.
10. SEE M-DWGS FOR HVAC REQUIREMENTS.
N
NOTE:
SEE CIVIL DRAWINGS C-104 & C-114 FOR TRUE
NORTH
PLAN NORTH
OS OS OS
OSOSOS
A-204
A-204
A-204
A-204
A-204
A-204
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
SL
O
PE
U
P
MECHANICAL DUCT
WITH EXHAUST
GRILLE, SEE M-DWGS.
TYP.
4'-0"
TYP.
5'-0"
8x8 HEAVY TIMBER, STAINED -
SEE S-DWGS
LIGHT FIXTURE -
SEE E-DWGS
N O
TE
LV
R
2' -0
'-4
SEE E-DWGS
NOTE 1, TYP.
NOTE 1, TYP.
NOTE 6, TYP.
NOTE 8
NOTE 6, TYP.NOTE 9
NOTE 9
WALL HEATER -
SEE M-DWGS
A-204
A-204
A-204
A-204
A-204
A-204
4"
1' -0
4"
1'
-0
DASHED LINE INDICATES
EXTERIOR FACE OF
STRUCTURAL BEAM
NON-VENTED RIDGE CAP
'-2
2' -3
/4
'-6
/2
2' -3
/4
2'-0" 26'-8" 2'-0"
30'-8"
VTR
NOTE 3
STANDING SEAM METAL ROOF -
SEE A-602 FOR DETAILS
DASHED LINE INDICATES
EXTERIOR FACE OF CMU @
BUILDING
CEILING LEGEND
HARD CEILING
CEMENTITIOUS BOARD,
PAINTED
SURFACE-MOUNTED LINEAR
LIGHT FIXTURE
SEE ELEC DWGS.
CEILING CAP/ SOUND BARRIER
INSULATION PLATE
ABOVE CEILING
(2'-0" FROM PERIMETER WALLS)
NOTES:
1. CEILING HEIGHT IS NOTED ON RCP AND ROOM
FINISH SCHEDULE.
2. SEE ELECTRICAL AND MECHANICAL DRAWINGS FOR
EXACT SIZES AND SPECIFICATIONS OF FIXTURES
AND EQUIPMENT.
3. ALL LIGHT FIXTURES AND MECHANICAL EQUIPMENT
ARE LOCATED ON THE REFLECTED CEILING PLAN.
ALL FIXTURES, EQUIPMENT, AND OTHER CEILING
ELEMENTS ARE TO BE CENTERED IN GYPSUM
CEILING OR SOFFIT UNLESS NOTED OTHERWISE.
ALL DIMENSIONS ON THIS SHEET ARE FROM FACE
TO FINISH FACE OR CENTER LINE REFERENCE
UNLESS NOTED OTHERWISE. CONTRACTOR SHALL
CONSULT THE ARCHITECT OF ANY CONFLICTS
PRIOR TO REVISING LOCATIONS.
4. FIELD COORDINATE PLENUM SPACE AS REQUIRED
AND NOTIFY ARCHITECT OF ANY VARIATION.
5. ALL EXPOSED STRUCTURE, ELECTRICAL CONDUITS,
AND FIRE SPRINKLER PIPING TO BE PAINTED.
SURFACE-MOUNTED LIGHT
FIXTURE
SEE ELEC DWGS.
CEILING HEATER
SEE MECH DWGS.
SUSPENDED LINEAR LIGHT
FIXTURE
SEE ELEC DWGS.
T&G WOOD CEILING AND
SOFFIT
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:35 :34
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-202
EH
CTH
WLD
3094.2301
08/30/24
BUILDINGS 200/300 -
CAMPGROUND BATH
HOUSE - REFLECTED
CEILING PLAN & ROOF
PLAN
SCALE: 1/4" = 1'-0"A-202
1 BUILDINGS 200/300 - REFLECTED CEILING PLAN
SCALE: 1/4" = 1'-0"A-202
2 BUILDINGS 200/300 - ROOF PLAN
NOTES:
1. SEE E-DRAWINGS FOR LIGHTING FIXTURES. MOUNT EXTERIOR FIXTURES w/BOT @ 7'-9" AFF AND INTERIOR FIXTURES w/BOT @ 8'-6" AFF.
2. SEE A-902 FOR TOILET ACCESSORIES & FIXTURES.
3. VENT THROUGH ROOF (VTR) - INSTALL VTR AFTER STANDING SEAM METAL ROOF. COORDINATE EXACT ROOF PENETRATION LOCATION TO
CENTER BETWEEN STANDING SEAMS. SEE 2/A-602.
4. WALL LOUVER (IN GABLE) - 2'-0"SQ w/BOT @ 11'-0" AFF CENTERED ON WALL. SEE M-DWGS.
5. SEE CIVIL DRAWINGS FOR EXACT FINISH FLOOR ELEVATION.
6. OCCUPANCY SENSORS WALL MOUNTED @ 8'-6" AFF. SEE E-DRAWINGS.
7. INSTALL SEALANT AT ALL WALL PENETRATIONS.
8. PHOTOCELL MOUNTED @ 9'-0" AFF. SEE E-DWGS.
9. T&G WOOD INDOOR AND OUTDOOR CEILINGS AND SOFFITS. TRIM WITH WOOD. STAINED.
10. ALL CEMENT BOARD, BATTENS, AND TRIM TO BE PAINTED EPP-1.
SCALE: 1/4" = 1'-0"
12 FT.8421.50
N
PLAN NORTH
8x8 HEAVY TIMBER -
SEE &
S-DWGS
/4 A-602
203 202 201
STANDING SEAM
METAL ROOF - SEE
A-602 FOR DETAILS
CEMENT BOARD
SIDING & TRIM
STONE VENEER
FASCIA - SEE DETAIL
DRINKING FOUNTAIN
W/ BOTTLE FILLER,
SEE M-DWGS
8x8 HEAVY TIMBER
COLUMN, STAINED
(TYP)
VENT, TYP.
STONE WATER TABLE
TRIPLE 2x8 BEAM -
SEE A-602 & S-DWGS
/4 A-602
206 207 208
LOUVER - SEE M-DWGS
2" 3'
-0
LIGHT FIXTURE -
SEE E-DRAWINGS
ELECTRIC METER
& DISCONNECT,
SEE E-DWGS
DD
TY
P.
8' -0
" A
FF
WALL HYDRANT,
SEE P-DWGS
ELECTRICAL
RECEPTACLE,
SEE E-DWGS.
4" 1'-0"
4" 1'-0"
T&G WOOD
SOFFIT, STAINED
NON VENTED RIDGE
205 204
4" 1'-0" 4"
1'-0"
7' -9
'-6
BEAM BRG HT
D D
PHOTOCELL - SEE E-DWGS
WALL HYDRANT,
SEE P-DWGS
LIGHT FIXTURE,
SEE E-DWGS
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:36 :34
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-203
EH
CTH
WLD
3094.2301
08/30/24
BUILDINGS 200/300 -
CAMPGROUND BATH
HOUSE - EXTERIOR
ELEVATIONS
SCALE: 1/4" = 1'-0"A-203
4 BUILDINGS 200/300 - SOUTH ELEVATION
SCALE: 1/4" = 1'-0"A-203
3 BUILDINGS 200/300 - NORTH ELEVATION
SCALE: 1/4" = 1'-0"A-203
2 BUILDINGS 200/300 - WEST ELEVATION
SCALE: 1/4" = 1'-0"A-203
1 BUILDINGS 200/300 - EAST ELEVATION
GENERAL NOTES:
1. INSTALL PERIMETER SEALANT AROUND
ALL WALL PENETRATIONS.
2. INSTALL SEALANT AT TOP AND SIDES OF
ALL ITEMS MOUNTED TO EXTERIOR WALLS.
3. PAINT ALL CEMENT BOARD PER
SPECIFICATIONS 099130. COLOR TO BE
SELECTED BY ENGINEER / ARCHITECT.
4. SEE NORTH ELEVATION FOR TYPICAL
NOTES.
56 SF
ALL-GENDER
SHOWER
169 SF
MECHANICAL
CHASE
70 SF
ALL-GENDER
RESTROOM
9"
CONCRETE SLAB -
SEE S-DWGS
4" POROUS
FILL
VAPOR
BARRIER
FOOTINGS -
SEE S-DWGS
A-204
A-602
A-602
A-602
A-602
8' -8
A-602
COLLAR TIES - SEE
S-DWGS
FINISHED FLOOR
42'-8" - SEE -S-DWGS
16"O.C. BOARD AND BATTEN
SPACING - COORDINATE FOR
ROOM SYMMETRY (TYP)
WALL HEATER (TYP) -
SEE M-DWGS
TOP/CMU
CEMENT BOARD,
PAINTED
9"
70 SF
ALL-GENDER
RESTROOM
70 SF
ALL-GENDER
RESTROOM
70 SF
ALL-GENDER
RESTROOM
CONCRETE SLAB -
SEE S-DWGS
4" POROUS
FILL
VAPOR
BARRIER
FOOTINGS - SEE
S-DWGS
8' -8
FINISHED FLOOR
30 SF
JANITORIAL
204 56 SF
ALL-GENDER
SHOWER
56 SF
ALL-GENDER
SHOWER
56 SF
ALL-GENDER
SHOWER
DRINKING FOUNTAIN
W/ BOTTLE FILLER -
SEE P-DWGS
SEE A-902 FOR ACCESSORIES
FOOTINGS - SEE
S-DRAWINGS
MOP SINK -M
SEE P-DWGS
VENT - SEE SPECS
FINISHED FLOOR
SLOPED SOLID SURFACE
TOP & END CAP -
PROVIDE P.T. FRAMING
AS REQ TO PROPERLY
SUPPORT
FLASHING & WEEPS
ABOVE LOOSE
LINTEL ANGLE - SEE
S-DWGS
CEMENT
BOARD,
PAINTED
16"O.C. BOARD AND BATTEN
SPACING - COORDINATE FOR
ROOM SYMMETRY (TYP)
P.T. SILL PLATE
2x6 STUD WALL @ 16" O.C.
CARRY CEMENT
BOARD DOWN CMU
WALL APPROX. 2".
BOND BEAM -
SEE S-DWGS
BOARD & BATTEN
CEMENT BOARD
PEAL & STICK
MEMBRANE ISOLATION
PAD BETWEEN WOOD
& CONCRETE (TYP)
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:38 :00
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-204
EH
CTH
WLD
3094.2301
08/30/24
BUILDINGS 200/300 -
CAMPGROUND BATH
HOUSE - BUILDING
SECTIONS
SCALE: 3/8" = 1'-0"A-204
1 BUILDINGS 200/300 - LONGITUDINAL SECTION
SCALE: 3/8" = 1'-0"A-204
2 BUILDINGS 200/300 - TRANSVERSE SECTION
SCALE: 3/8" = 1'-0"A-204
3 BUILDINGS 200/300 - TRANSVERSE SECTION
SCALE: 1 1/2" = 1'-0"A-204
4 DETAIL
VALLEY VALLEY
R
ID
G E
RIDGERIDGE
A-301
A-301
A-301
A-301
EXISTING STONE CHIMNEY W/
NEW METAL CHIMNEY CAP
R
ID
G E
CERTI-SAWN PRESERVATIVE TREATED
SHAKES SHINGLES, NO. 1 GRADE AND 16"
LENGTH W/ A WEATHER EXPOSURE OF 5"
CERTI-SAWN PRESERVATIVE
TREATED SHAKES SHINGLES,
NO. 1 GRADE AND 16" LENGTH
W/ A WEATHER EXPOSURE OF 5"
VENTED RIDGE CAP
FELT UNDERLAYMENT T&G ROOFING DECK
1" THICK VENTILATED RIDGE
PROVIDE 2" AIR GAP IN ROOF
DECK FOR NATURAL VENTILATION
EXISTING WOOD RAFTERS
EXISTING RIDGE BEAM
COPPER VALLEY FLASHING
EXTEND 12" EACH SIDE OF
VALLEY CENTERLINE
FELT UNDERLAYMENT
T&G ROOFING
DECK
CERTI-SAWN PRESERVATIVE
TREATED SHAKES SHINGLES,
NO. 1 GRADE AND 16" LENGTH
W/ A WEATHER EXPOSURE OF 5"
EXISTING WOOD
RAFTERS
CERTI-SAWN PRESERVATIVE
TREATED SHAKES SHINGLES,
NO. 1 GRADE AND 16" LENGTH
W/ A WEATHER EXPOSURE OF 5"
T&G ROOFING DECK
SEALANT AND BACKER ROD
1/4"H DAM
1 1/2" DEEP SAW CUT REGLET
IN WALL STEP FLASHING -
SECURE W/ LEAD WEDGES
EXISTING STONE CHIMNEY
BREAK METAL CHIMNEY
COVER W/ X-BEND TO
SHED WATER, COLOR TO
BE SELECTED BY OWNER
FELT UNDERLAYMENT
SELF-TAPPING SCREW
T&G ROOFING DECK
FELT UNDERLAYMENT
CERTI-SAWN PRESERVATIVE
TREATED SHAKES SHINGLES,
NO. 1 GRADE AND 16" LENGTH
W/ A WEATHER EXPOSURE OF 5"
6" COPPER STEP
FLASHING
EXISTING STONE
CHIMNEY
BREAK METAL CHIMNEY
COVER W/ X-BEND TO
SHED WATER, COLOR TO
BE SELECTED BY OWNER
SAWCUT AND INSTALL
REGELT PER DETAIL 2/A-301
A-301
EXISTING WOOD
RAFTERS
1. THE CONTRACTOR SHALL COVER ALL ROOF SURFACES WITH CERTI-SAWN® PRESERVATIVE
TREATED SHAKES SHINGLES BEARING THE CEDAR SHAKE & SHINGLE BUREAU®’S OFFICIAL
GRADE MARKED LABEL AS MANUFACTURED BY CEDAR SHAKE AND SHINGLE BUREAU (CSSB)
MEMBERS.
2. SHAKES/SHINGLES FOR ROOFS SHALL BE NO. 1 GRADE AND 16” LENGTH.
3. ROOF SHAKES/SHINGLES SHALL BE LAID WITH A WEATHER EXPOSURE OF 5” INCHES.
4. CERTI-SAWN® SHAKES SHALL BE APPLIED OVER SOLID SHEATHING. A SOLID DECK IS
RECOMMENDED IN SEISMIC ACTIVITY, HURRICANE AND TORNADO REGIONS AND IN AREAS
WHERE WIND-DRIVEN SNOW IS ENCOUNTERED AND UNDER PRESSURE IMPREGNATED TREATED
SHAKES AND SHINGLES.
5. CONTRACTOR SHALL APPLY A 36" WIDE STRIP OF NO. 30 ASTM D226 TYPE II OR NO. 30 ASTM D4869 TYPE LV ROOFING FELT AT THE EAVE LINE. AN 18" WIDE STRIP OF NO. 30 ASTM D226 TYPE II OR NO. 30 ASTM D4869 TYPE LV ROOFING FELT SHALL BE APPLIED OVER THE TOP PORTION OF
THE CERTI-LABEL® SHAKES AND EXTEND ONTO THE SHEATHING. BOTTOM EDGE OF FELT SHALL
BE POSITIONED AT A DISTANCE ABOVE THE BUTT EQUAL TO TWICE THE WEATHER EXPOSURE.
6. SHAKES/SHINGLES SHALL BE AT LEAST DOUBLED AT ALL EAVES.
7. BUTTS OF THE SHAKES/SHINGLES IN THE FIRST COURSE ON ROOFS SHALL PROJECT 1 1/2" FROM
THE EDGE OF ROOF EAVES TO INSURE PROPER SPILL INTO GUTTERS AND APPROXIMATELY 1" AT
GABLE AND RAKE EDGE.
8. CERTI-SAWN® SHAKES SHALL BE SPACED APART NOT LESS THAN 3/8", NOT
MORE THAN 5/8".
9. CHIMNEY FLASHING SHALL EXTEND UP THE CHIMNEY TO A HEIGHT NOT LESS THAN 3", UP THE ROOF SLOPE TO A POINT EQUAL IN HEIGHT TO THE FLASHING ON THE CHIMNEY BUT NEVER LESS
THAN 1 1/2 TIMES THE SHAKE/SHINGLE EXPOSURE.
10. APRON COUNTER FLASHING SHALL EXTEND TO WITHIN 1" OF THE SURFACE OF THE FINISHED
ROOF.
11. WHERE SADDLES OR CRICKETS ARE FORMED IN BACK OF CHIMNEYS, CURVES OR SIMILAR
VERTICAL SURFACES, THEY SHALL BE CARRIED NOT LESS THAN 10" UNDER THE
SHAKES/SHINGLES.
12. STEP FLASHING SHALL BE USED WHERE VERTICAL SURFACES OCCUR IN CONNECTION WITH
SLOPES. THEY SHALL BE FORMED OF SEPARATE PIECES. FLASHING SHALL EXTEND
HORIZONTALLY NOT LESS THAN 3" AND UP THE VERTICAL WALL SO THAT THEY SHALL BE LAPPED BY THE COUNTER FLASHING NOT LESS THAN 4". IT SHALL BE INSTALLED IN STEP FASHION AND
EACH PIECE SHALL LAP NOT LESS THAN 3" (ONE FLASHING INSTALLED ON EACH COURSE
CONCEALED UNDER THE COVERING COURSE). IF OTHER THAN MASONRY IS USED THE FLASHING
SHALL EXTEND UP THE WALL NOT LESS THAN 3" BEHIND THE SHEATHING PAPER.
GENERAL NOTES
13. ALL SHAKE/SHINGLE HIPS AND RIDGES SHALL BE OF ALTERNATE OVERLAP TYPE
APPLIED AT THE SAME EXPOSURE AS FIELD OF ROOF AND WITH NAILS LONG ENOUGH TO
PENETRATE INTO SHEATHING AT LEAST 3/4”, POSITION FASTENERS APPROXIMATELY 2”
ABOVE EXPOSURE LINE. INSTALL A STRIP OF FELT, EAVE PROTECTION MATERIAL OR
METAL OVER HIP OR RIDGE UNDER THE RIDGE OR HIP CAP. IF LONGER OR SHORTER RIDGE
CAP IS USED, ADJUST EXPOSURE ACCORDINGLY.
14. SHAKES/SHINGLES EXTENDING INTO THE VALLEY SHALL BE SAWED TO THE PROPER MITER.
15. DO NOT LAY SHAKES OR SHINGLES WITH GRAIN PARALLEL WITH THE CENTERLINE OF
VALLEYS.
16. ALL VALLEYS SHALL BE INSTALLED WITH SHAKES/SHINGLES LAPPING THE VALLEY
FLASHING NOT LESS THAN 7" ON EACH SIDE.
17. ON SHINGLE ROOFS OF LESS THAN 6:12 SLOPE, FLASHING SHOULD EXTEND AT LEAST 11”
ON EACH SIDE.
18. FOR SHAKES, METAL VALLEY SHEETS SHALL BE CENTER-CRIMPED; OF 20" MINIMUM WIDTH;
UNDERLAYED WITH A STRIP OF NO. 30 ASTM D226 TYPE LL OR NO. 30. ASTM D4869 TYPE LV
ROOFING FELT OVER THE SHEATHING, AND COATED WITH A METAL PAINT.
19. CERTI-LABEL® ROOF SHAKES AND SHINGLES SHALL BE SECURED WITH TWO (2)
FASTENERS: STAINLESS STEEL TYPE 304, TYPE 316, OR HOT-DIPPED GALVANIZED WITH A
COATING WEIGHT OF ASTM A153 CLASS D 2 (1.0 OZ/FT ).FOR PRESSURE–IMPREGNATED
TREATED PRODUCTS FASTENERS USED WITH PRESERVATIVE-TREATED (CERTI-LAST®)
SHAKES OR SHINGLES MUST BE STAINLESS STEEL TYPE 316. FASTENERS SHALL BE LONG
ENOUGH TO PENETRATE INTO THE SOLID WOOD SHEATHING AT LEAST 3/4”.
20. NAILS SHALL BE DRIVEN FLUSH BUT NOT SO THAT THE NAIL HEAD CRUSHES THE WOOD.
THEY SHALL BE PLACED APPROXIMATELY 3/4" TO 1" FROM THE SIDE EDGES OF THE
SHAKES/SHINGLES AND APPROXIMATELY 1 1/2" ABOVE THE BUTT LINE OF THE FOLLOWING
COURSE.
21. EACH ROOF SHAKE/SHINGLE SHALL BE SECURED WITH TWO FULL-DRIVEN, CORROSION
RESISTANT FASTENERS.
22. USE 3D “BOX” NAILS FOR NEW ROOFS WITH 16" AND 18" SHINGLES.
23. USE 5D "BOX" NAILS FOR OVER-ROOFING WITH 16" AND 18" SHINGLES, AND FOR HIPS AND
RIDGES.
24. 6D NAILS ARE USUALLY ADEQUATE FOR CERTI-LABEL® SHAKES, BUT LONGER NAILS SHALL
BE USED AS CERTI-LABEL® SHAKE OR SHINGLE THICKNESS OR WEATHER EXPOSURE
DICTATES.
JOHNSON, LASCHOBER & ASSOCIATES, P.C.
ARCHITECTS ENGINEERS
LANDSCAPE ARCHITECTS
1296 BROAD ST., AUGUSTA, GEORGIA 30901
PHONE: (706) 724-5756 FAX: (706) 724-3955
WEBSITE: www.theJLAgroup.com
NO.
United States Department of Agriculture Forest Service
R-08 Southern Region
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
DATE ARCHIVE NUMBER
DESIGNER DRAWING SHEET NO.
DRAWN
CHECKED
PROJECT NO.
PREPARED BY:
SHEET OF
LAKE WINFIELD SCOTT
CAMPGROUND
RECONSTRUCTION
439 LAKE WINFIELD SCOTT ROAD
SUCHES, GA 30572
Project Issue Date: 08/30/2024 Project Status: Final Construction Documents Contract Number: 12445223C0003
CHATTAHOOCHEE - OCONEE NATIONAL
FOREST, BLUE RIDGE RANGER
DISTRICT, UNIT ID CODE 0803
REVISION/ISSUE DATE
8/3 0/2
4 9
:38 :45
A M
C:
\R ev it L oc al
Pr oje cts \30
_L ak e W inf iel d S co tt\3
1_ Ar ch ite ctu ra l-L oc al_ ch olr oy d.r vt
A-301
EH
JNA
WLD
3094.2301
08/30/24
PICNIC PAVILION - ROOF
PLAN & DETAILS
SCALE: 1/4" = 1'-0"A-301
1 ROOF PLAN - PICNIC PAVILION
SCALE: 3" = 1'-0"A-301
2 RIDGE DETAIL
SCALE: 3" = 1'-0"A-301
3 VALLEY DETAIL
SCALE: 3" = 1'-0"A-301
4 STEP FLASHING & CHIMNEY CAP DETAIL
SCALE: 1 1/2" = 1'-0"A-301
5 STEP FLASHING ELEVATION
8" CMU
WALL
3' -2
" T O
P O
F C
AP
THRU-WALL FLASHING
W/WEEPS @ 24" O.C.
STONE VENEER
5/8" ZIP SHEATHING
SYSTEM
BOARD & BATTEN
SIDING
CEMENT BOARD
LAP SIDING
SHIM
(2) LAYERS OF 1 X 4
FIBER CEMENT TRIM
FLASHING
DRAINAGE MAT
5/8" ZIP SHEATHING
SYSTEM
P.T. SILL PLATE
BOND BEAM - SEE S-DWGS
BOARD & BATTEN
CEMENT BOARD
FLASHING SET IN A
FULL BED OF SEALANT
OPEN HEAD
WEEPS @ 24"
O.C.
R-19 BATT
INSULATION
STONE SILL
CAP
4"+-
FOUNDATION VENT -
SEE SHEET A-201
FOR LOCATIONS
PEEL & STICK MEMBRANE
ISOLATION PAD BETWEEN
WOOD & CONC. (TYP)
1" AIR GAP
MORTAR NET
WALL TIES
GROUT FILL WALL
CAVITY UP TO FINISHED
GRADE AND INSTALL
FLASHING AND WEEPS -
SEE C-DWGS
CEMENT BOARD
WASH
2" RIGID
INSULATION
8" CMU WALL
FINISH FLOOR - SEE
FINISH SCHEDULE
T&G WOOD CEILINGS &
SOFFIT ON EXTERIOR -
SEE BUILDING SECTIONS
8'-8" AFF
6" WOOD STUD WALL W/
CEMENT BOARD EACH
SIDE
PT 2x6
BATT INSULATION
8" CMU BOND BEAM -
SEE S-DWGS
VERTICAL REINFORCING -
SEE S-DWGS
HORIZONTAL REINFORCING -
SEE S-DWGS
PEEL & STICK
MEMBRANE
3'
4" A
FF
3" PVC PIPE SLEEVE
FOR FLEX SHOWER
PIPING - SEE P-DWGS 2x4 WOOD STUDS
@ 16" O.C.
SOUND BATT
INSULATION
5/8" GYPSUM
BOARD EACH
SIDE
CEILINGS @ 9'-0"AFF
SCHEDULED
BASE
FINISH FLOOR -
SEE FINISH
SCHEDULE
5/8" GYPSUM
BOARD
P.T. WOOD
SILL PLATE
PEEL & STICK
MEMBRANE
STONE VENEER
R-19 BATT
INSULATION
GROUT FILL WALL
CAVITY UP TO FINISHED
GRADE AND INSTALL
FLASHING AND WEEPS -
SEE C-DWGS
STONE SILL CAP
BOARD & BATTEN
SIDING
5/8" ZIP SHEATHING
SYSTEM
2x6 WOOD STUDS @ 16" O.C.
5/8" GYPSUM WALLBOARD
3' -2
" T O
P O
F C
AP
FLASHING SET IN A
FULL BED OF SEALANT
P.T. WOOD SILL PLATE
OPEN HEAD
WEEPS @ 24" O.C.
FACE\STUDFACE\STONE
1" AIR GAP
DRAINAGE MAT
PEEL & STICK MEMBRANE
MORTAR NET
WALL TIES
4" +/- 1 3/4"
THRU-WALL FLASHING
W/WEEPS @ 24" O.C.
8x8 HEAVY TIMBER BEAM -
STAINED - SEE S-DWGS
8X8 HEAVY TIMBER
WOOD COLUMN -
STAINED - SEE S-DWGS
CEMENT BOARD
SIDING
FASCIA
STANDING SEAM METAL
ROOF - SEE A-602
5/8" ZIP SHEATHING
SYSTEM
GABLE END FRAMING
WOOD FRAMING -
SEE S-DWGS
T&G WOOD SOFFIT
LOUVER - BOT @ 10'9" AFF
SEE FOR DETAILS/8 A-801
DRAINAGE MAT
FLASHING W/ DRIP
RIDGE
T&G CEILING - SEE FINISH
SCHEDULE
5/8" ZIP SHEATHING
SYSTEM - WRAP R.O.
WITH ZIP FLASHING
SYSTEM TO INSIDE
FACE OF R.O.
VERTICAL SIDING
(CEMENT BOARDS)
VERTICAL SIDING
(BATTENS @ 18" O.C.)
8" CMU BOND BEAM -
SEE S-DRAWINGS FOR
REINFORCING, TYP.
P.T. BLOCKING
BACKER ROD &
SEALANT - DO NOT
BLOCK WEEPS
ALUMINUM FRAME
SILL FLASHING:
HEMMED FRONT DRIP
WITH 1/2" H REAR &
SIDE DAMS - SET IN A
FULL BED OF
SEALANT
FACE OF CMU
PEEL & STICK
MEMBRANE
DRAINAGE MAT
1/2"
SOLID SURFACE
SILL SET IN A FULL
BED OF SEALANT
1"
SEALANT
2" RIGID INSULATION
ALUMINUM FRAME
OUTRIGGERS
@ 16" O.C. RAFTERS @
16" O.C.
This is the start of the file's text. The full file is on GovTribe.