10967 50 Construction Documents Set.pdf
PDF 6 MB Posted
- Attached to
- CM Services - KSC Student Center, Mabel Brown Room Theatrical and House Lighting Upgrades
- Solicitation number
- 212027989
- Issued by
- New Hampshire
About this file
Summary
This is a 50% Construction Documents Set for the Mabel Brown Room Theatrical & House Lighting Upgrades project at Keene State College in Keene, New Hampshire, prepared by RFS Engineering and Jones Architecture, Inc. The project encompasses comprehensive theatrical and house lighting upgrades across the second and third floors of the Mabel Brown Room within the Student Center. The scope includes demolition of existing ceiling-mounted lighting fixtures, acoustic tile, and theatrical equipment; installation of new theatrical dimmer panels (two IQ48 panels and one DdR6 panel); replacement of house lighting with LED equivalents; installation of new theatrical lighting fixtures including ColorSource units, Selador fixtures, and high-end portable lighting; and implementation of an advanced lighting control system with network capabilities. The construction documents are presented in 50% completion stage, dated June 19, 2026, with architectural and electrical coordination drawings showing both base and alternate design options. The project involves detailed demolition notes, electrical plans for both floors, lighting schedules with fixture specifications, and control system wiring diagrams.
The construction documents specify multiple lighting fixture types for theatrical applications ranging from 56.8 watts to 550 watts, with manufacturers including ETC and High End Systems. The project includes both base design options utilizing standard LED fixtures with 0-10V dimming and alternate designs featuring RGBW color-mixing capabilities with DMX control. Emergency lighting provisions are integrated throughout, with emergency relay systems and dual-circuit fixtures as required. The lighting control infrastructure includes an Ion Xe 20 control console, Response MK2 gateways, Paradigm touchscreen stations, and Ethernet-based network communications. All work must comply with applicable National Electrical Code standards, NFPA guidelines, and state electrical licensing requirements. The construction documents indicate coordination between electrical contractors, architectural teams, and the owner, with specific provisions for temporary wiring during phased construction and comprehensive testing protocols for systems placed back in service during construction phases.
View the file
Other files
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.rfsengineering.com
Boston, MA | Laconia, NH | Portland, ME
Keene State College
Mabel Brown Room Theatrical & House Lighting Upgrades
229 Main Street Keene, NH 03431
RFS Project #: 10967.001
June 19, 2026
Copyright © 2026 RFS Engineering
Drawing No.Stamp
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
50% Construction Documents
/1
/2
:3
:1
P
M TS
TITLE SHEET
TS TITLE SHEET
ARCHITECTURAL
AD111 DEMO RCPS
AD420 DEMO ELEVATIONS
A111 PROPOSED RCPS
A420 PROPOSED ELEVATIONS
ELECTRICAL
E0.1 ELECTRICAL LEGEND, NOTES & ABBREVIATIONS
E0.2 ELECTRICAL SECOND FLOOR REFERENCE PLAN
E0.3 ELECTRICAL THIRD FLOOR REFERENCE PLAN
ED1.1 ELECTRICAL SECOND FLOOR DEMOLITION PLAN
ED1.2 ELECTRICAL THIRD FLOOR DEMOLITION PLAN
E1.1 ELECTRICAL SECOND FLOOR NEW CONSTRUCTION PLAN - BASE
E1.2 ELECTRICAL THIRD FLOOR NEW CONSTRUCTION PLAN - BASE
E1.3 ELECTRICAL THIRD FLOOR NEW CONSTRUCTION THEATRICAL PLAN
E1.4 ELECTRICAL SECOND FLOOR NEW CONSTRUCTION PLAN - ALTERNATE
E1.5 ELECTRICAL THIRD FLOOR NEW CONSTRUCTION PLAN - ALTERNATE
E2.1 LIGHTING SCHEDULES - BASE
E2.2 LIGHTING SCHEDULES - ALTERNATE
E2.3 ELECTRICAL LIGHTING DETAILS & DIAGRAMS
AD420
7.1
D
7.8 8.5 9.6 106.1
C
B
A
24' - 0" 18' - 0" 18' - 0" 24' - 0" 6' - 0"
LIMIT OF WORK
9' - 6"
9' - 6"
9' - 6"
9' - 6"
9' - 6"
9' - 6"
2 4
OPEN TO ABOVE
SEE 2/AD111
OPEN TO ABOVE
OPEN TO ABOVE
REFLECTED CEILING PLAN DEMO LEGEND
KEY NUMBER
DEMO TAG - SEE KEYNOTE LEGEND
EXISTING LIGHT FIXTURE TO BE REMOVED
EXISTING ACT CEILING TO BE REMOVED.
EXISTING WALL/ COLUMN TO REMAIN
EXISTING EXIT SIGN TO BE REMOVED.
REFER TO ELECTRICAL PLANS
ALSO SEE SYMBOL LEGEND ON COVERSHEET/A000
EXISTING ACT CEILING TO REMAIN.
EXISTING GWB CEILING TO REMAIN.
SPRINKLER TO BE REMAIN
SURFACE MOUNTED FIXTURE TO BE REMOVED
AND SALVAGED FOR REINSTALLATION
AD420
7.1
D
7.8 8.5 9.6 106.1
C
B
A
24' - 0" 18' - 0" 18' - 0" 24' - 0" 6' - 0"
LIMIT OF WORK
9' - 0"
15' - 4"
16' - 0"
15' - 8"
8' - 6"
9' - 0"
15' - 4"
9' - 0"9' - 0"
9' - 0"
16' - 0" 16' - 0" 16' - 0" 16' - 0"
16' - 0"16' - 0"16' - 0"16' - 0"
9' - 0"
9' - 0"
9' - 0"
15' - 8"
15' - 8"
15' - 8"
1 1
1 1
1 1
1 1
MULTI PURPOSE
RM
STAGE
STAIR 3
STAIR 4
STORAGE
SERVICE
CTRL.ROOM
CORR.
BALCONY
MULTI PURPOSE
RM
STAGE
STAIR 3
STAIR 4
STORAGE
SOUND ROOM
PROJ. ROOM
CORR.
TRASH
JAN.
A. ALL KEY NOTES INDICATE PROMINENT FEATURES OF THE DEMOLITION
PLAN. DEMOLITION PLANS ARE NOT LIMITED TO KEY NOTES. DEMOLITION
ENTAILS REMOVAL OF ELEMENTS ABOVE AND BEYOND THOSE ITEMS
INDICATED IN KEY NOTES. DEMOLITION CONTRACTOR IS REQUIRED TO
VISIT SITE TO UNDERSTAND COMPLETE SCOPE OF DEMOLITION WORK.
B. SEE MEP FOR DEMOLITION EXISTING MECHANICAL / PLUMBING AND
ELECTRICAL PIPING, VENTS, LIGHTING OR OTHER COMPONENTS.
C. REFER TO SPECIFICATION FOR GENERAL REQUIREMENTS FOR
DEMOLITION AND RELATED WORK.
D. CONTRACTOR TO DO ALL DEMOLITION WORK REQUIRED TO ACCOMPLISH
NEW CONSTRUCTION AND WORK.
E. REMOVE MEANS THAT ITEMS SHALL BE DETACHED FROM EXISTING
CONSTRUCTION AND LEGALLY DISPOSED OF OFF-SITE, UNLESS
INDICATED TO BE REMOVED AND SALVAGED OR REMOVED AND
REINSTALLED.
F. EXISTING TO REMAIN INDICATES EXISTING ITEMS OF CONSTRUCTION
THAT ARE NOT TO BE REMOVED.
G. REMOVE AND SALVAGE MEANS THAT ITEMS SHALL BE DETACHED FROM
EXISTING CONSTRUCTION AND CLEANED MOVED TO STORAGE PLACE AS
DESIGNATED BY THE OWNER.
DEMOLITION GENERAL NOTES
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Drawings
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
2622_RFS-Keene St_R24.rvt
1/8" = 1'-0"
/1
/2
:3
:3
A
M AD111
DEMO RCPS
JB
CS
CS
RCP DEMOLITION NOTES
1 REMOVE ALL ACT AND GRIDS, AS WELL AS ALL CEILING MOUNTED LIGHT FIXTURES.
ALL EXISTING CEILING MOUNTED DEVICES, EQUIPMENT, SPRINKLER HEADS, AND
DIFFUSERS AND GRILLES ARE TO REMAIN. U.N.O. ITEMS DIRECTLY ATTACHED TO THE
CEILING GRID OR TILES SHALL BE TEMPORARILY SUPPORTED AS NEEDED AND
REINSTALLED IN THE NEW GRID OR TILE IN THE SAME LOCATIONS.
2 REMOVE THEATRICAL LIGHT FIXTURES, ALSO REFER TO ELECTRICAL DRAWINGS.
3 REMOVE AND SALVAGE CEILING MOUNTED PIPE GRID FOR REINSTALLATION.
4 EXISTING CONT. CEILING MOUNTED RACEWAY TO REMAIN.
5 REMOVE AND SALVAGE "QUARTER MOON" LIGHT FIXTURES AT HIGH CEILING FOR
REINSTALLATION. REFER TO ELECTRICAL DRAWINGS.
6 REMOVE PENDANT LIGHTS ABOVE STAGE, ALSO REFER TO ELECTRICAL DRAWINGS.
7 REMOVE AND SALVAGE STAGE CURTAINS FOR REINSTALLATION.
SCALE: 1/8" = 1'-0"AD111
1 LEVEL 2 - DEMO RCP
N
4'0 8' 16'
GRAPHIC SCALE
SCALE: 1/8" = 1'-0"AD111
2 LEVEL 3 - DEMO RCP
Rev. Issued Date
LEVEL 2
EL. +13'-4" (13.33)
7.1
LEVEL 3
EL. +26'-8" (26.67)
7.8 8.5
DEMO SECTIONS OF GWB
SOFFIT AS REQD. FOR
STRUCTURAL WORK
(APPROX 70 SQFT)
HIGH CEILING
EL. +42'-8"
REMOVE AND SALVAGE
LIGHTING GRID FOR
REINSTALLATION.
REMOVE THEATRICAL
LIGHT FIXTURES
LEVEL 2
EL. +13'-4" (13.33)
7.1
LEVEL 3
EL. +26'-8" (26.67)
7.88.5
DEMO SECTIONS OF GWB
SOFFIT AS REQD. FOR
STRUCTURAL WORK
(APPROX 70 SQFT)
HIGH CEILING
EL. +42'-8"
REMOVE AND SALVAGE
LIGHTING GRID FOR
REINSTALLATION.
REMOVE THEATRICAL
LIGHT FIXTURES
LEVEL 2
EL. +13'-4" (13.33)
D
LEVEL 3
EL. +26'-8" (26.67)
C B
DEMO SECTIONS OF GWB
SOFFIT AS REQD. FOR
STRUCTURAL WORK
(APPROX 70 SQFT)
HIGH CEILING
EL. +42'-8"
REMOVE AND SALVAGE
ACOUSTIC WALL PANELS
REMOVE AND SALVAGE
LIGHTING GRID FOR
REINSTALLATION.
REMOVE THEATRICAL
LIGHT FIXTURES
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Drawings
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
2622_RFS-Keene St_R24.rvt
1/8" = 1'-0"
/1
/2
:3
:5
A
M AD420
DEMO ELEVATIONS
JB
CS
CS
SCALE: 1/8" = 1'-0"AD420
1 DEMO ELEVATION NORTH
SCALE: 1/8" = 1'-0"AD420
2 DEMO ELEVATION SOUTH
SCALE: 1/8" = 1'-0"AD420
3 DEMO ELEVATION WEST
REFLECTED CEILING PLAN LEGEND
ACT
2'-0" x 2'-0"
CEILING TYPES
GYPSUM BOARD
EXIT SIGN
(FILL INDICATES FACE)
RECESSED CAN
2x2 RETURN GRILL
2x2 SUPPLY GRILL2'x2' TROFFER
2'x4' TROFFER
LIGHT FIXTURES MECHANICAL ITEMS
LINEAR PENDANT
RECESSED LINEAR
RECESSED CEILING
PROJECTOR SCREEN
RADIANT CEILING
PANELS
SURFACE MOUNTED
LINEAR SUPPLY GRILL
EXPOSED
CEILING
EXPOSED
SPRINKLER HEAD
7.1
D
7.8 8.5 9.6 106.1
C
B
A
A420
24' - 0" 18' - 0" 18' - 0" 24' - 0" 6' - 0"
LIMIT OF WORK
9' - 6"
9' - 6"
MULTI PURPOSE
RM
STAGE
9' - 6"
9' - 6"
OPEN TO ABOVE,
SEE 2/A111
OPEN TO ABOVE
OPEN TO ABOVE
1 1
CORR.
CTRL.ROOM
SERVICE
STORAGE
STAIR 4
STAIR 3
7.1
D
7.8 8.5 9.6 106.1
C
B
A
A420
24' - 0" 18' - 0" 18' - 0" 24' - 0" 6' - 0"
LIMIT OF WORK
8' - 6"15' - 4"
15' - 8"
15' - 4"
9' - 0"
9' - 0"
9' - 0"
16' - 0"
15' - 8"
9' - 0"9' - 0"
9' - 0"
16' - 0"
16' - 0"
16' - 0"
16' - 0"
16' - 0"16' - 0"16' - 0"16' - 0"
9' - 0"
10' - 0"
15' - 8" 15' - 8"
15' - 4"
15' - 4"
15' - 4"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
BALCONY
MULTI PURPOSE
RM
STAGE
CORR.
JAN.
TRASH
PROJ. ROOM
SOUND ROOM
STORAGE
STAIR 4
STAIR 3
ACOUSTIC CEILING TILE
1. BASIS OF DESIGN: ARMSTRONG DUNE, TEGULAR, 24"X24", COLOR: WHITE.
9/16" GRID.
2. ALTERNATE: ARMSTRONG FINE FISSURED, TEGULAR 24"X24", COLOR:
LIGHT GRAY. 9/16" GRID
PAINTING
1. BASIS OF DESIGN: PATCH AND PAINT THE ENTIRETY OF THE BALCONY
WALL WHERE NEW LIGHTING BARS ARE INSTALLED. MATCH EXISTING
COLOR AND SHEEN. APPROX 410 SF.
2. ALTERNATE: PAINT ALL GWB WALLS, SOFFITS/CEILINGS, AND COLUMN
ENCLOSURES WITHIN THE SPACE, APPROX X,XXX SF. NEW PAINT COLORS
TBD.
FINISHES AND ALTERNATES
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Drawings
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
2622_RFS-Keene St_R24.rvt
As indicated
/1
/2
:3
:2
A
M A111
PROPOSED RCPS
JB
CS
CS
SCALE: 1/8" = 1'-0"A111
1 LEVEL 2 - RCP
N
4'0 8' 16'
GRAPHIC SCALE
SCALE: 1/8" = 1'-0"A111
2 LEVEL 3 - RCP
RCP NEW WORK KEY NOTES 01
1 PROVIDE NEW ACT AND CEILING GRID. NEW LIGHT FIXTURES PER ELECTRICAL
DRAWINGS. REINSTALL ALL SALVAGED CEILING MOUNTED DEVICES, EUIPMENT,
SPRINKLER HEADS AND DIFFUSERS AND GRI
2 INSTALL NEW THEATRICAL LIGHT FIXTURES PER ELECTRICAL PLANS
3 REINSTALL THE EXISTING PIPE GRIDS IN THEIR ORIGINAL LOCATIONS.
4 INSTALL NEW LIGHT BAR PER STRUCTURAL DRAWINGS.
LEVEL 2
EL. +13'-4" (13.33)
7.1
LEVEL 3
EL. +26'-8" (26.67)
7.8 8.5
HIGH CEILING
EL. +42'-8"
PATCH & PAINT GWB WALL +/- 410 SF
REINSTALL LIGHTING
GRID IN EXISTING
LOCATION
REFER TO EL DRAWINGS
FOR NEW LIGHTING
NEW LIGHT BAR, REFER TO
ELECT & STRUCT DRAWINGS
LEVEL 2
EL. +13'-4" (13.33)
7.1
LEVEL 3
EL. +26'-8" (26.67)
7.88.5
HIGH CEILING
EL. +42'-8"
PATCH & PAINT GWB WALL +/- 410 SF
REINSTALL LIGHTING GRID
IN EXISTING LOCATION
REFER TO EL DRAWINGS
FOR NEW LIGHTING
NEW LIGHT BAR, REFER TO
ELECT & STRUCT DRAWINGS
LEVEL 2
EL. +13'-4" (13.33)
D
LEVEL 3
EL. +26'-8" (26.67)
C B
HIGH CEILING
EL. +42'-8"
PATCH & PAINT GWB WALL +/- 410 SF
REINSTALL LIGHTING GRID IN
EXISTING LOCATION
REFER TO EL DRAWINGS
FOR NEW LIGHTING
NEW LIGHT BAR, REFER TO
ELECT & STRUCT DRAWINGS
REINSTALL ACOUSTIC WALL
PANELS
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Drawings
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
2622_RFS-Keene St_R24.rvt
1/8" = 1'-0"
/1
/2
:3
:4
A
M A420
PROPOSED
ELEVATIONS
JB
CS
CS
SCALE: 1/8" = 1'-0"A420
1 PROPOSED ELEVATION NORTH
SCALE: 1/8" = 1'-0"A420
2 PROPOSED ELEVATION SOUTH
SCALE: 1/8" = 1'-0"A420
3 PROPOSED ELEVATION WEST
SWITCHING & WIRING LEGEND
S
S S
{ E# }
LP1(#)
SINGLE POLE SWITCH, MH = 44"AFF, UON
3 = THREE-WAY
4 = FOUR-WAY
PL = PILOT LIGHT
D = DIMMER
VS = VARIABLE SPEED CONTROLLER
K = KEY OPERATED
O = OCCUPANCY SENSOR
OD = DUAL RELAY OCCUPANCY SENSOR
T = DIGITAL TIMER
LV = LOW VOLTAGE
DOUBLE SWITCHING, ONE SWITCH SHALL CONTROL
INBOARD LAMP, OTHER SWITCH SHALL CONTROL
OUTBOARD LAMP(S) OF CONTROLLED LIGHTING CIRCUIT
LIGHTING CONTROL PANEL CIRCUIT NUMBER
EMERGENCY LIGHTING CONTROL PANEL CIRCUIT NUMBER
HOMERUN TO DESIGNATED PANELBOARD, (#=QUANTITY
OF HOMERUNS IF MULTIPLE) (2#12&1#12G-3/4"C., UON)
X
X
DEMOLITION LEGEND
EXISTING EQUIPMENT OR DEVICE TO BE REMOVED
EXISTING EQUIPMENT OR DEVICE TO REMAIN
XRL = EXISTING RELOCATED
XRU = EXISTING BOX & CONDUIT REUSED
XTR = EXISTING TO REMAIN
XR = EXISTING TO BE REMOVED
ELECTRICAL WIRING CIRCUIT (IN WALLS AND CEILINGS)
ELECTRICAL WIRING CIRCUIT (BELOW FLOOR OR SLAB)
SWITCH OR CONTROL CIRCUIT
EMERGENCY LIGHTING AC CIRCUIT
DC CIRCUIT
CONNECTION AT EQUIPMENT
POWER LEGEND
NEW SURFACE MOUNTED PANELBOARD
NEW RECESSED MOUNTED PANELBOARD
EXISTING SURFACE MOUNTED PANELBOARD
EXISTING RECESSED MOUNTED PANELBOARD
DRY-TYPE TRANSFORMER
FUSED DISCONNECT SWITCH
JUNCTION BOX
ENCLOSED CIRCUIT BREAKER
J
CB
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
C COUNTER HEIGHT
CLG CEILING MOUNTED
DN DOWN
DWG DRAWING
EC ELECTRICAL CONTRACTOR
FIBO FURNISHED AND INSTALLED BY OWNER/OTHERS
HP HORSEPOWER
LOR LOCATED ON ROOF
MC MECHANICAL CONTRACTOR
MCB MAIN CIRCUIT BREAKER
MD MOTORIZED DOOR **
MH MOUNTING HEIGHT
NTS NOT TO SCALE
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
PC PLUMBING CONTRACTOR
S/S START/STOP PUSH BUTTONS
S. STL STAINLESS STEEL
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
VP VANDAL PROOF
WG WIRE GUARD
* EQUIPMENT PROVIDED BY MECHANICAL TRADE, WIRED BY
ELECTRICAL TRADE
** EQUIPMENT PROVIDED BY DOOR HARDWARE TRADE, WIRED
BY ELECTRICAL TRADE
ABBREVIATIONS
CIRCUIT BREAKER TYPES
AF
G H
L
S
AFCI CIRCUIT BREAKER
GFCI CIRCUIT BREAKER
HACR CIRCUIT BREAKER
LOCKED-ON CIRCUIT
SHUNT TRIP CIRCUIT BREAKER
ONE-LINE LEGEND
NEW WIRE OR DEVICE
EXISTING WIRE OR DEVICE TO REMAIN
EXISTING WIRE OR DEVICE TO BE REMOVED
CIRCUIT BREAKER, ET = ELECTRONIC TRIP
TRANSFORMER
IDENTIFICATION FOR WIRE SIZE &
QUANTITY (SEE FEEDER SCHEDULE)
SWITCH
GENERAL NOTES
THE FOLLOWING GENERAL NOTES APPLY TO ALL RIST-FROST-SHUMWAY ENGINEERING,
INC., DRAWINGS AND TRADES ASSOCIATED WITH THOSE DRAWINGS INVOLVED ON THIS
PROJECT:
RIST-FROST-SHUMWAY ENGINEERING, INC., WAIVES ANY AND ALL
RESPONSIBILITY AND LIABILITY FOR PROBLEMS WHICH ARISE FROM FAILURE TO
FOLLOW THESE PLANS, SPECIFICATIONS AND/OR THE DESIGN INTENT THEY
CONVEY, OR FOR PROBLEMS WHICH ARISE FROM OTHERS' FAILURE TO OBTAIN
AND/OR FOLLOW THE GUIDANCE OF RIST-FROST-SHUMWAY ENGINEERING, INC.,
WITH RESPECT TO ANY ERRORS, OMISSIONS, INCONSISTENCIES, AMBIGUITIES
OR CONFLICTS WHICH ARE IS COVERED OR ALLEGED.
ALL WORK SHALL CONFORM TO ALL FEDERAL, STATE, AND LOCAL CODES AND
STANDARDS INCLUDING, BUT NOT LIMITED TO: NFPA, IBC, UL, SMACNA, OSHA,
AND NEC.
THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL PROTECT THE WORK
SITE, SURROUNDING AREAS AND OCCUPANTS FROM DAMAGE AND INJURY.
THE CONTRACTOR AND ALL SUBCONTRACTORS SHALL FAMILIARIZE
THEMSELVES WITH THE CONTRACT DOCUMENTS. ALL DRAWINGS OF ANY
PARTICULAR TRADE SHALL BE USED IN CONJUNCTION WITH DRAWINGS OF ALL
OTHER TRADES TO COORDINATE ALL CONSTRUCTION. ANY DISCREPANCIES
SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE
PROCEEDING WITH THE AFFECTED WORK. ANY PROPOSED CHANGES,
VARIATIONS OR SUBSTITUTIONS MUST BE REVIEWED AND ACCEPTED BY THE
ENGINEER PRIOR TO IMPLEMENTATION.
ALL DRAWINGS ARE INTENDED TO SHOW THE GENERAL ARRANGEMENT, DESIGN
INTENT AND EXTENT OF THE WORK. THEY SHALL BE CONSIDERED PARTLY
DIAGRAMMATIC. THEY ARE NOT INTENDED TO BE SCALED FOR ROUGHING-IN
MEASUREMENTS OR TO SERVE AS SHOP DRAWINGS.
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL DIMENSIONS (AS-BUILT
OR OTHERWISE) BEFORE COMMENCING FABRICATION, AND/OR ORDERING
MATERIALS.
DETAILS SHOWN ON ANY DRAWING ARE TO BE CONSIDERED TYPICAL FOR ALL
SIMILAR CONDITIONS, UNLESS OTHERWISE INDICATED.
INFORMATION ON THESE DRAWINGS PERTAINING TO AS-BUILT CONSTRUCTION
AND OTHER EXISTING CONDITIONS HAVE BEEN OBTAINED FROM OTHER
DOCUMENTATION OR BY FIELD INVESTIGATION. (SEE GENERAL AND
SUPPLEMENTAL CONDITIONS FOR LISTING). THIS INFORMATION IS PROVIDED
FOR THE CONTRACTOR'S BENEFIT IN PERFORMANCE OF THE WORK.
G-1
G-2
G-3
G-4
G-5
G-6
G-7
G-8
ELECTRICAL TRADE NOTES
ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH ALL APPLICABLE
NATIONAL, STATE AND LOCAL CODES AND THE CURRENT NATIONAL ELECTRICAL CODE
(NEC) BY ELECTRICIANS LICENSED BY THE STATE IN WHICH THE WORK IS PERFORMED.
THE ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION AND ELECTRICAL
REQUIREMENTS OF ALL EQUIPMENT PRIOR TO INSTALLING ANY CONDUIT AND/OR CABLE. IF
ELECTRICAL REQUIREMENTS DIFFER FROM THOSE INDICATED, OR IF ADDITIONAL
EQUIPMENT IS REQUIRED BY CODE, INFORM THE ENGINEER.
WIRING FOR ALL SINGLE PHASE CIRCUITS, 20A OR SMALLER, SHALL BE A MINIMUM OF 2#12
&1#12G-3/4"C., FOR CIRCUIT LENGTHS UNDER 100FT AND 2#10&1#10G-3/4"C., FOR CIRCUIT
LENGTHS 100FT AND OVER , UNLESS OTHERWISE NOTED. CIRCUITS FOR ISOLATED
GROUND RECEPTACLES SHALL INCLUDE ADDITIONAL ISOLATED GROUND CONDUCTOR.
CIRCUITS FOR DOUBLE SWITCHED LIGHT FIXTURES SHALL INCLUDE ADDITIONAL SWITCHED
CONDUCTOR(S) AS REQUIRED. THE SHARING OF NEUTRAL CONDUCTORS IS NOT
ALLOWED.
MOUNTING HEIGHTS GIVEN FOR ALL WIRING DEVICES (WALL SWITCHES, RECEPTACLES,
ETC.), TELEPHONE EQUIPMENT, SPEAKERS AND LIGHT FIXTURES ARE TO THE CENTERLINE
OF THE JUNCTION BOX USED TO MOUNT THE DEVICE, UNLESS OTHERWISE NOTED.
REMOVE AND DISPOSE OF EXISTING ELECTRICAL EQUIPMENT AND ASSOCIATED BOXES,
CONDUIT AND WIRE WHERE INDICATED OR WHERE LOCATED ON OR WITHIN WALLS AND
CEILINGS BEING DEMOLISHED OR ALTERED AS A RESULT OF THIS CONTRACT, UNLESS
OTHERWISE INDICATED. IT IS NOT THE INTENT OF THESE DRAWINGS TO INDICATE ALL
ELECTRICAL ITEMS TO BE REMOVED.
CIRCUIT WIRING INDICATED ON DRAWINGS IS SCHEMATIC IN NATURE AND SHALL NOT BE
CONSIDERED TO BE POINT-TO-POINT, UNLESS OTHERWISE NOTED.
EXISTING ELECTRICALLY POWERED ITEMS THAT REMAIN SHALL BE RECIRCUITED, IF
NECESSARY, TO ENSURE CONTINUED OPERATION.
COORDINATE FINAL LOCATIONS OF CEILING LIGHT FIXTURES AND OTHER EQUIPMENT WITH
REFLECTED CEILING PLANS AND ALL OTHER TRADE DRAWINGS PRIOR TO INSTALLATION.
WHERE LONG CIRCUIT LENGTHS ARE REQUIRED, ENSURE LESS THAN
3% VOLTAGE DROP UNDER FULL LOAD. INCREASE WIRE SIZE ON CIRCUITS 100 FEET LONG
AND ABOVE.
PROVIDE AND ENSURE FIREPROOFING OF ALL CONDUIT, CABLING AND ANY OTHER
ELECTRICAL DEVICES THROUGH FIRE RATED ASSEMBLIES.
PROVIDE PULL STRINGS IN ALL CONDUIT SYSTEMS LEFT FOR USE BY OTHERS.
MOUNTING HEIGHT FOR ELECTRICAL DEVICES (RECEPTACLES, MULTICOMMUNICATIONS
OUTLETS, ETC) LOCATED ON WALLS ABOVE FINTUBE SHALL BE 4" FROM TOP OF FINTUBE
ENCLOSURE TO CENTERLINE OF ELECTRICAL DEVICE.
PROVIDE EXPANSION FITTINGS IN CONDUIT RISERS FROM ALL EXTERIOR UNDERGROUND
CONDUITS TO FIXED EQUIPMENT OR CONDUIT FITTINGS AND PROVIDE FLEXIBLE
CONNECTIONS TO ANY EQUIPMENT SUBJECT TO SETTLEMENT OR FROST HEAVES.
WHERE DOUBLE SWITCHES ARE INDICATED, FIXTURES SHALL BE PROVIDED WITH
MULTIPLE BALLASTS.
E-1
E-2
E-3
E-4
E-5
E-6
E-7
E-8
E-9
E-10
E-11
E-12
E-13
E-14
A1
A1
TH1TH1
TC
LC
D
E
LCRP#
C#
PC1
LCN#
EB1
LR1
LR3
a
PANEL-#
(E) a
PANEL-#
(E)
T1 a PANEL-#
PANEL-#
X1 X1
X1
OS1
a
PANEL-# a a
OS2
a
OS3
a
OS4
a
OS5
a
OS6
a
OS7
a
PANEL-#
a a
LR2
a
LIGHT FIXTURE
REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION.
A1 = FIXTURE TYPE
a = SWITCHING OR DIMMING ZONE
PANEL-# = PANEL AND CIRCUIT #
(E) = FIXTURE CONNECTED TO EMERGENCY CIRCUIT
(N/L) = NIGHT LIGHT, WIRED CONSTANT ON
(E/N) = DUAL CIRCUIT - FIXTURE CONNECTED TO EMERGENCY AND
NORMAL
TRACK LIGHTING FIXTURE(S)
REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION.
T1 = TRACK TYPE
TH1 = TRACK HEAD TYPE
a = SWITCHING OR DIMMING ZONE
PANEL-# = PANEL AND CIRCUIT #
WALL MOUNTED EMERGENCY BATTERY FIXTURE
REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION.
EB1 = FIXTURE TYPE
PANEL-# = PANEL AND CIRCUIT #
CEILING MOUNTED EMERGENCY BATTERY FIXTURE
REFER TO LIGHTING FIXTURE SCHEDULE FOR ADDITIONAL INFORMATION.
EB1 = FIXTURE TYPE
PANEL-# = PANEL AND CIRCUIT #
WALL MOUNTED EMERGENCY BATTERY PACK
EB1 = FIXTURE TYPE
a = SWITCHING ZONE CONTROLLED
PANEL-# = PANEL AND CIRCUIT #
WALL MOUNTED REMOTE EMERGENCY FIXTURE HEAD(S)
EB1 = FIXTURE TYPE
a = SWITCHING ZONE CONTROLLED
PANEL-# = PANEL AND CIRCUIT #
WALL MOUNTED EXIT LIGHT
FILLED AREA INDICATES FACE LOCATION. PROVIDE WITH ARROW
DIRECTION INDICATING CHEVRONS AS SHOWN ON PLANS. REFER TO
TYPICAL DEVICE LOCATIONS, UON. REFER TO LIGHTING FIXTURE SCHEDULE
FOR ADDITIONAL INFORMATION.
X1 = FIXTURE TYPE
PANEL-# = PANEL AND CIRCUIT #
• = INTERNATIONAL SYMBOL OF ACCESSIBILITY
CEILING/PENDANT MOUNTED EXIT LIGHT
FILLED AREA INDICATES FACE LOCATION. PROVIDE WITH ARROW
DIRECTION INDICATING CHEVRONS AS SHOWN ON PLANS. REFER TO
TYPICAL DEVICE LOCATIONS, UON. REFER TO LIGHTING FIXTURE SCHEDULE
FOR ADDITIONAL INFORMATION.
X1 = FIXTURE TYPE
PANEL-# = PANEL AND CIRCUIT #
• = INTERNATIONAL SYMBOL OF ACCESSIBILITY
LIGHTING CONTROL RELAY MODULE
20A DIMMING, WIRED, UNIVERSAL VOLTAGE, (0-10V)
DIMMING, SYSTEM CONNECTED, WIRED FOR DIMMING U.O.N. REFER TO
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
a = SWITCHING OR DIMMING ZONE CONTROLLED
PANEL-# = PANEL AND CIRCUIT #
LIGHTING CONTROL RELAY MODULE
20A SWITCHING, WIRED, UNIVERSAL VOLTAGE, ON/OFF, SYSTEM
CONNECTED. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
a = SWITCHING OR DIMMING ZONE CONTROLLED
PANEL-# = PANEL AND CIRCUIT #
LIGHTING CONTROL RELAY MODULE
PHASE CUT DIMMING, WIRED, UNIVERSAL VOLTAGE INPUT, FORWARD
PHASE & REVERSE PHASE DIMMING, SYSTEM CONNECTED. REFER TO
SPECIFICATIONS FOR ADDITIONAL INFORMATION.
a = SWITCHING OR DIMMING ZONE CONTROLLED
PANEL-# = PANEL AND CIRCUIT #
PANEL-#
PANEL-#
PANEL-#
PANEL-#
PANEL-#
PANEL-#
a
EB1
PANEL-#
a
PANEL-#
a
PANEL-#
PANEL-#
a
X1
EB1
EB1
EB1
PC2
a
LIGHTING LEGEND
WHU
P
CPS
CEILING MOUNTED VACANCY SENSOR
WIRED, 360°, DUAL-TECHNOLOGY (INFRARED / ULTRASONIC),
SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
CEILING MOUNTED OCCUPANCY SENSOR
WIRED, 360°, ULTRASONIC, SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
CEILING MOUNTED OCCUPANCY SENSOR
WIRED, 360°, INFRARED, SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
WALL MOUNTED OCCUPANCY SENSOR
WIRED, DUAL-TECHNOLOGY (INFRARED / ULTRASONIC),
SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
WALL MOUNTED OCCUPANCY SENSOR
WIRED, ULTRASONIC, SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
WALL MOUNTED OCCUPANCY SENSOR
WIRED, INFRARED, SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
CEILING MOUNTED OCCUPANCY SENSOR
HIGH BAY, WIRED, 360°, INFRARED, SYSTEM CONNECTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
LOW VOLTAGE LIGHTING CONTROL STATION
SYSTEM CONNECTED
# = STATION NUMBER. REFER TO CONTROL STATION ELEVATIONS
AND DETAILS.
a = SWITCHING OR DIMMING ZONE CONTROLLED
DAYLIGHTING CONTROL PHOTOCELL SENSOR
WIRED, SYSTEM CONNECTED, MOUNT PER MANUFACTURER'S
SPECIFICATIONS.
a = SWITCHING OR DIMMING ZONE CONTROLLED
EXTERIOR DAYLIGHTING CONTROL PHOTOCELL SENSOR
WEATHPROOF, WIRED, SYSTEM CONNECTED, MOUNT PER
MANUFACTURER'S SPECIFICATIONS.
a = SWITCHING OR DIMMING ZONE CONTROLLED
REMOTE DRIVER OR POWER SUPPLY
EMERGENCY LIGHTING TRANSFER DEVICE WITH TEST SWITCH, UL924
LISTED.
a = SWITCHING OR DIMMING ZONE CONTROLLED
PANEL-# = PANEL AND CIRCUIT #
LIGHTING CONTROL RELAY PANEL
REFER TO LIGHTING CONTROL WIRING DIAGRAMS.
# = STATION NUMBER.
DIGITAL TIMECLOCK
LIGHTING CONTACTOR WITH CONTACTS RATED AS REQUIRED
LIGHTING CONTROL NETWORK EQUIPMENT
# = STATION NUMBER.
EMERGENCY PULL ROPE CORRIDOR DOME LIGHT
CEILING MOUNTED PARTITION SENSOR
CEILING MOUNTED WIRELESS HUB UNIT
NO SCALE
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:2
P
M E0.1
ELECTRICAL LEGEND,
NOTES &
ABBREVIATIONS
CEG
AMS
PGW
MAIN SWITCHBOARD
350A /3P
225kVA
480V-120/208V
150A /3P
600A /3P
SR24
DIMMER
PANEL
SR48
DIMMER
PANEL
MAIN SWITCHBOARD
350A /3P
225kVA
480V-120/208V
150A /3P
400A /3P
DdR6
DIMMER
PANEL
IQ48
DIMMER
PANEL
IQ48
DIMMER
PANEL
EMERGENCY RELAY
EMERGENCY RELAY
SPLICE 200A WIRING TO
400A WIRING TO SPLIT
FEEDER
ONE-LINE DEMOLITION NOTES
1. DISCONNECT EXISTING SR24 DIMER PANEL AND REMOVE.
MAINTAIN EXISTING FEEDER AND CIRCUIT BREAKER COMPLETE.
2. DISCONNECT EXISTING AR48 DIMER PANEL AND REMOVE.
REMOVE EXISTING FEEDR COMPLETE. MAINTAIN EXISTING
CIRCUIT BREAKER FOR REUSE.
3. REMOVE EXISTING EMERGENCY LIGHTING RELAY FOR
REPLACEMENT. MAINTAIN EXISTING DISCONNECT AND BRANCH
CIRCUIT COMPLETE.
ONE-LINE NEW WORK NOTES
1. INSTALL NEW DdR6 DIMMER PANEL TO REPLACE EXISTING SR24
HOUSE DIMEMR PANEL. CONNECT TO EXISTING FEEDER
MAINTAINED. RECONNECT EXISTING CIRCUITS MAINTAINED TO
NEW DIMMER PANEL. ANY NEW CONDUIT AND WIRING SHALL
MATCH EXISTING IN ALL RESPECTS.
2. ADJUST EXISTING 600A BREAKER DOWN TO 400A FOR NEW
FEED. WITHIN EXISTING TROUGH, SPLICE NEW 400A FEEDER TO
(2) 200A FEEDERS FOR NEW LOADS TO IQ48 DIMMER PANELS.
3. CONNECT NEW EMERGENCY RELAY TO EXISTING BRANCH
CIRCUIT MAINTAINED. ANY NEW CONDUIT AND WIRING SHALL
MATCH EXISTING IN ALL RESPECTS.
EXISTING WIRE-TROUGH
EXISTING WIRE-TROUGH
PARTIAL ONE-LINE DIAGRAM - DEMOLITION
SCALE: N.T.S.
PARTIAL ONE-LINE DIAGRAM - DEMOLITION
SCALE: N.T.S.
400F
400F
200F
1 2
7.1
D
7.8 8.5 9.6 106.15.14.12.91.91
C
B
A
E
F
G
AREA OF WORK
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:2
P
M E0.2
ELECTRICAL SECOND
FLOOR REFERENCE
PLAN
CEG
AMS
PGW
7.8 8.5 9.6 106.15.14.12.91.91
C
B
A
E
F
G
AREA OF WORK
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:2
P
M E0.3
ELECTRICAL THIRD
FLOOR REFERENCE
PLAN
CEG
AMS
CB
CBCB
7.1
D
7.8 8.5 9.6 106.15.1
C
B
A
E
XR
XR
XR
XR
XRXR
XRXR
XR XR XR XR XR XR
XR XR XR XR XR XR
XR XR
XR
XRXR
XRXR
XRXR
XRXRXRXRXR
XR XR XR XR
XR XR XR XR
XRXRXRXR
XR
XR XR XR XR
XR XR XR XR
XR
XR XR XR XR
XRXRXRXR
XR
XR XR XR
XRXRXR
XR XR XR XR
XR
XR
XR
XR
XR
XR
XR
XR
OPEN TO
ABOVE
XTR
XTR
XTR XTR
XTR
XTR
XTR
XTR
XR
XR
XR
XR
NIC
NIC
NIC
LL6
LL5
LH3
XR
XTRXTR
XR
XR
EXISTING WIRE
TROUGH
XTR
STAGE
DIMMER FEED
HOUSE
DIMMER FEED
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:2
P
M ED1.1
ELECTRICAL SECOND
FLOOR DEMOLITION
PLAN
CEG
AMS
PGW
KEYED NOTES :
1. EXISTING SR48 DIMMER TO BE REMOVED
AND REPLACED WITH (2) IQ48 DIMMER
RACKS. REMOVE EXISTING FEEDER
COMPLETE. REMOVE EXISTING
DISCONNECT SWITCH COMPLETE.
2. EXISTING SR24 DIMMER TO BE REMOVED
AND REPLACED WITH (1) DrD6 DIMMER.
MAINTAIN EXISTING ENCLOSED CIRCUIT
BREAKER AND FEEDER COMPLETE FOR
REUSE.
3. REMOVE EXISTING EMERGENCY LIGHTING
RELAY BETWEEN DIMMING PANELS.
MAINTAIN EXISTING CIRCUITRY FOR
REUSE.
DRAWING NOTES:
A. REFER TO ARCHITECTURAL DRAWINGS, DETAILS AND ELEVATIONS FOR
COORDINATION OF ALL DEMOLITION WORK
B. EXISTING BRANCH CIRCUITS SHALL BE MAINTAINED AND UTILIZED FOR NEW LIGHTING
FIXTURES. EC SHALL INSPECT INTEGRITY OF WIRING AND REPLACE IF ANY FOUND
DAMAGED, FREYED, OR DETERIORATING DUE TO AGE.
ELECTRICAL DEMOLITION NOTES
AS DIRECTED BY THE OWNER, ALL EXISTING ELECTRICAL SYSTEMS, EQUIPMENT AND
APPURTENANCES LOCATED IN THE EXISTING FACILITY ARE TO BE CAREFULLY
DISASSEMBLED AND REMOVED, SALVAGED, AND TURNED OVER TO THE OWNER,
UNLESS INDICATED TO BE REUSED ON THE ARCHITECTURAL AND/OR ELECTRICAL
PLANS AND SPECIFICATIONS.
NO EXISTING ELECTRICAL EQUIPMENT, SYSTEMS, OR APPURTENANCES SHALL BE
ABANDONED IN PLACE. (NOTE: CONDUIT LOCATED IN EXISTING WALLS TO REMAIN
AND FLOOR SLABS MAY BE ABANDONED IN PLACE OR REUSED.
WHERE EQUIPMENT OR APPURTENANCES ARE REMOVED WHICH WERE BUILT-IN TO
EXISTING CONSTRUCTION, COORDINATE WITH THE CONSTRUCTION
MANAGER/GENERAL CONTRACTOR TO PATCH AND/OR REPAIR ALL SUCH AREAS IN
ACCORDANCE WITH APPROVED CONSTRUCTION METHODS AND FINISHES, AS
DIRECTED BY THE CONTRACT DRAWINGS, SPECIFICATIONS, AND/OR THE
ARCHITECT/ENGINEER.
COORDINATE WITH THE CONSTRUCTION MANAGER/GENERAL CONTRACTOR AND ALL
OTHER SUB-CONTRACTORS IN ORDER TO DETERMINE OVERALL PROJECT PHASING
AND DEMOLITION WORK SEQUENCING. COORDINATE REQUIRED DEMOLITION BY
OTHER TRADES RESULTING FROM ELECTRICAL SYSTEMS DEMOLITION.
PROTECT ALL EXISTING FINISHES WHICH ARE TO REMAIN.
REFER TO THE ARCHITECTS DEMOLITION NOTES AND PROJECT SPECIFICATIONS
FOR ADDITIONAL DEMOLITION INFORMATION AND REQUIREMENTS.
ALL PCB TYPE LIGHTING FIXTURE BALLASTS TO BE REMOVED SHALL BE TURNED
OVER TO THE ABATEMENT CONTRACTOR FOR FURTHER DISPOSITION.
REMOVE AND DISPOSE OF EXISTING ELECTRICAL EQUIPMENT AND ASSOCIATED
BOXES, CONDUIT AND WIRE WHERE INDICATED OR WHERE LOCATED ON OR WITHIN
WALLS AND CEILINGS BEING DEMOLISHED OR ALTERED AS A RESULT OF THIS
CONTRACT, UNLESS OTHERWISE INDICATED. IT IS NOT THE INTENT OF THESE
DRAWINGS TO INDICATE ALL ELECTRICAL ITEMS TO BE REMOVED.
EXISTING ELECTRICALLY POWERED ITEMS THAT REMAIN SHALL BE RECIRCUITED, IF
NECESSARY, TO ENSURE CONTINUED OPERATION.
WORK FOR THIS PROJECT WILL BE PHASED, AS DIRECTED BY THE OWNER. WHEN A
PARTIAL SYSTEM IS PLACED BACK IN SERVICE DURING CONSTRUCTION. THE SYSTEM
SHALL BE TESTED TO ENSURE IT IS FULLY OPERATIONAL. THIS SHALL INCLUDE, BUT
NOT BE LIMITED TO POWER, FIRE ALARM, LIGHTING, EMERGENCY LIGHTING, EXIT
SIGNAGE, DATA, TELEPHONE, AND P/A SYSTEMS.
REMOVE OR MODIFY THE PART OF EACH ELECTRICAL SYSTEM CORRESPONDING TO
THE PHASING PLANS FOR THE PROJECT. PROVIDE TEMPORARY WIRING FOR EACH
SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION.
FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE
MADE FOR ADDITIONAL COSTS DUE TO THE CONTRACTOR'S FAILURE TO FIELD
VERIFY EXISTING CONDITIONS AND DIMENSIONS.
D-1
D-2
D-3
D-4
D-5
D-6
D-7
D-8
D-9
D-10
D-11
D-12
7.8 8.5 9.6 106.15.1
C
B
A
E
XR XR XR XR XR XR
XR XR XR XR XR XR
XR XR
XR
XRXR
XRXR
XR
XR
XRXRXRXR
XR
XR
XRXR
XR
XR
XRXR
XR XR XR
XR
XR XR
XR
XR
XR
XRXR
XR
XR
XR
XR
XR
XR
XR XR
XR XR XR
XRXRXRXR
XR XR
XR
XR
XR XR
XR
XR
XR
XR
XR
XRXRXR
XR XR XR XR
XR XR
XR XR
XR XR
XR
XR XR XR
XR
XR
XR
XRXR
XR
XR XR
XRXR
XR
XR
XR
XR
XR
XR
XR XR
XTR
XTR
XTRXTR
XTRXTR
XTR
XTRXTRXTR
XTR
XTR
XTR XTR XTR XTR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR
XR XR XR XR
XRXR
XR XR
XRXR
XR XR
XRXRXRXR
XR XR XR XR
XRXR
XR XR
XRXR
XR XR
XRXR
XTR
XTR
XTR
XTR
XR
NIC
XR
XR
XR
XR
(TYP.)
(TYP.)
(TYP.)
XR
NIC
NIC
XTR
(TYP.)
(TYP.)
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M ED1.2
ELECTRICAL THIRD
FLOOR DEMOLITION
PLAN
CEG
AMS
PGW
DRAWING NOTES: KEYED NOTES :
1. REPLACE EXISTING LAMPS WITH LED
EQUIVALENTS. FINAL LAMP TYPE (STATIC
WHITE OR RGBW) TO BE CONFIRMED
WITH ARCHITECT/OWNER.
2. ALL EXISTING TRACK HEADS SHALL BE
REMOVED.
3. EXISTING THEATRICAL PIPE GRID TO
REMAIN.
A. REFER TO ARCHITECTURAL DRAWINGS, DETAILS AND ELEVATIONS FOR
COORDINATION OF ALL DEMOLITION WORK
B. EXISTING BRANCH CIRCUITS SHALL BE MAINTAINED AND UTILIZED FOR NEW LIGHTING
FIXTURES. EC SHALL INSPECT INTEGRITY OF WIRING AND REPLACE IF ANY FOUND
DAMAGED, FREYED, OR DETERIORATING DUE TO AGE.
ELECTRICAL DEMOLITION NOTES
AS DIRECTED BY THE OWNER, ALL EXISTING ELECTRICAL SYSTEMS, EQUIPMENT AND
APPURTENANCES LOCATED IN THE EXISTING FACILITY ARE TO BE CAREFULLY
DISASSEMBLED AND REMOVED, SALVAGED, AND TURNED OVER TO THE OWNER,
UNLESS INDICATED TO BE REUSED ON THE ARCHITECTURAL AND/OR ELECTRICAL
PLANS AND SPECIFICATIONS.
NO EXISTING ELECTRICAL EQUIPMENT, SYSTEMS, OR APPURTENANCES SHALL BE
ABANDONED IN PLACE. (NOTE: CONDUIT LOCATED IN EXISTING WALLS TO REMAIN
AND FLOOR SLABS MAY BE ABANDONED IN PLACE OR REUSED.
WHERE EQUIPMENT OR APPURTENANCES ARE REMOVED WHICH WERE BUILT-IN TO
EXISTING CONSTRUCTION, COORDINATE WITH THE CONSTRUCTION
MANAGER/GENERAL CONTRACTOR TO PATCH AND/OR REPAIR ALL SUCH AREAS IN
ACCORDANCE WITH APPROVED CONSTRUCTION METHODS AND FINISHES, AS
DIRECTED BY THE CONTRACT DRAWINGS, SPECIFICATIONS, AND/OR THE
ARCHITECT/ENGINEER.
COORDINATE WITH THE CONSTRUCTION MANAGER/GENERAL CONTRACTOR AND ALL
OTHER SUB-CONTRACTORS IN ORDER TO DETERMINE OVERALL PROJECT PHASING
AND DEMOLITION WORK SEQUENCING. COORDINATE REQUIRED DEMOLITION BY
OTHER TRADES RESULTING FROM ELECTRICAL SYSTEMS DEMOLITION.
PROTECT ALL EXISTING FINISHES WHICH ARE TO REMAIN.
REFER TO THE ARCHITECTS DEMOLITION NOTES AND PROJECT SPECIFICATIONS
FOR ADDITIONAL DEMOLITION INFORMATION AND REQUIREMENTS.
ALL PCB TYPE LIGHTING FIXTURE BALLASTS TO BE REMOVED SHALL BE TURNED
OVER TO THE ABATEMENT CONTRACTOR FOR FURTHER DISPOSITION.
REMOVE AND DISPOSE OF EXISTING ELECTRICAL EQUIPMENT AND ASSOCIATED
BOXES, CONDUIT AND WIRE WHERE INDICATED OR WHERE LOCATED ON OR WITHIN
WALLS AND CEILINGS BEING DEMOLISHED OR ALTERED AS A RESULT OF THIS
CONTRACT, UNLESS OTHERWISE INDICATED. IT IS NOT THE INTENT OF THESE
DRAWINGS TO INDICATE ALL ELECTRICAL ITEMS TO BE REMOVED.
EXISTING ELECTRICALLY POWERED ITEMS THAT REMAIN SHALL BE RECIRCUITED, IF
NECESSARY, TO ENSURE CONTINUED OPERATION.
WORK FOR THIS PROJECT WILL BE PHASED, AS DIRECTED BY THE OWNER. WHEN A
PARTIAL SYSTEM IS PLACED BACK IN SERVICE DURING CONSTRUCTION. THE SYSTEM
SHALL BE TESTED TO ENSURE IT IS FULLY OPERATIONAL. THIS SHALL INCLUDE, BUT
NOT BE LIMITED TO POWER, FIRE ALARM, LIGHTING, EMERGENCY LIGHTING, EXIT
SIGNAGE, DATA, TELEPHONE, AND P/A SYSTEMS.
REMOVE OR MODIFY THE PART OF EACH ELECTRICAL SYSTEM CORRESPONDING TO
THE PHASING PLANS FOR THE PROJECT. PROVIDE TEMPORARY WIRING FOR EACH
SYSTEM TO REMAIN OPERATIONAL DURING CONSTRUCTION.
FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO BID. NO ALLOWANCE WILL BE
MADE FOR ADDITIONAL COSTS DUE TO THE CONTRACTOR'S FAILURE TO FIELD
VERIFY EXISTING CONDITIONS AND DIMENSIONS.
D-1
D-2
D-3
D-4
D-5
D-6
D-7
D-8
D-9
D-10
D-11
D-12
CB CB
CBCB
C
C
C1
C1
C1
C
C
C
C
C3
OS1 OS1
OS1 OS1
OS1
C3
C3
C3
7.1
D
7.8 8.5 9.6 106.15.1
C
B
A
E
XTR
XTR
XTR
XTR
XTR
XTR
XTR XTR
NIC
NIC
NIC
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
TL4 TL4 TL4
TL4 TL4 TL4
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k k k k k k k
TL5
(E) (E) (E)
(E)
(E)
(E)
(E)
(E)
(E)
(E) (E) (E)
(E)
TL2 TL2 TL2
TL2 TL2 TL2
IQ48(2)
IQ48(1)
DdR6
EDBK
XTR XTR
XTR
STAGE
DIMMER FEED
HOUSE
DIMMER FEED
EXISTING WIRE
TROUGH
MINI DIN RAIL ENCLOSURE
DMX EMERGENCY BYPASS (ABOVE)
EQUIPMENT RACK
LL6
LL5
LH3
LLA
LL7
MULTI PURPOSE
RM
STAGE
C1
C1 m m m m
(E)
(E) n n n
OPEN TO
ABOVE
C1 m
(E)
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M E1.1
ELECTRICAL SECOND
FLOOR NEW
CONSTRUCTION PLAN
- BASE
CEG
AMS
PGW
KEYED NOTES :
1. MOUNT THEATRICAL LIGHT BAR ON FACE
OF BALCONY AT WOOD TRIM.
THEATRICAL LUMINAIRES SHALL BE
MOUNTED AT MINIMUM 13'- 0" AFF.
2. NEW IQ48 THEATRICAL DIMMER PANELS.
PROVIDE NEW FEEDERS. UTILIZE
EXISTING BREAKER. REFER TO ONE-LINE
DIAGRAMS ON DRAWING E0.1 FOR
ADDITIONAL INFORMATION.
3. ADJUST EXISITING BREAKER TO 400A FOR
NEW LOAD. REFER TO ONE-LINE
DIAGRAMS ON DRAWING E0.1 FOR
ADDITIONAL INFORMATION.
4. NEW DdR6 HOUSE DIMMER PANEL.
CONNECT TO EXISTING FEEDER
MAINTAINED. ANY NEW CONDUIT AND
WIRING TO MATCH EXISTING IN ALL
RESPECTS.
5. NEW EMERGENCY LIGHTING RELAY.
CONNECT TO EXISTING FEEDER
MAINTAINED. ANY NEW CONDUIT AND
WIRING TO MATCH EXISTING IN ALL
RESPECTS.
6. UTILIZE EXISTING SPARE BREAKERS
WITHIN EXISTING PANELS FOR NEW
LOADS INDICATED BY HOMERUNS.
CONTRACTOR TO VERIFY EXISTING
CIRCUITS TO BE UTILIZED. IF NO SPARE
BREAKERS EXIST, PROVIDE NEW 20A/1P
BREAKERS AS REQUIRED TO SUPPORT
ADDITIONAL LOADS.
7. DMX BYPASS AND DIN RAIL PART OF
LIGHTING ALTERNATE. CIRCUITS
REQUIRED ONLY IF ALTERNATE IS
ACCEPTED.
C
C
C1
C1
OS1 OS1
OS1
OS1 OS1
OS1
OS1
OS1
OS1
OS1
7.1
D
7.8 8.5 9.6 106.15.1
C
B
A
E
XTR
XTR
XTR
XTR
XTR
f
XTR
XTR XTR
XTR
f
XTRXTR
ff
XTR XTR
NIC
NIC
NIC
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 c
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F1 d
F2 a
F2 a
F2 a
F2 a
F2 a
F3 b
F3 b
F3 b
F3 b
F3 b
F3 b
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a
F1 a a,b,c,d a,b,c,d a,b,c,d a,b,c,d
F4 h
F4 h
F4 F4 F4
F4
F4 i i h i h
F5 j
F5 j
(TYP.)
XTR
XTRXTR
XTR
F4F4
F4F4
F4
F4 F4
F4 F4
F5 F5 j j hh ii i h h i i
F5 j
F5 j
F5
F5 j j
F6 n
F6 n
(E)
(E)
(E)
(E) (E) (E) (E) (E)
(E) (E) (E) (E)(E)
(E)
(E)
(E)
(E)
(E) (E)
(E)(E) f f ff g gg g
XTR XTRXTRXTR
g ggg
MULTI PURPOSE
RM
STAGE
BALCONY
n n
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M E1.2
ELECTRICAL THIRD
FLOOR NEW
CONSTRUCTION PLAN
- BASE
CEG
AMS
PGW
KEYED NOTES :
1. REPLACE EXISTING LAMPING WITH LED
EQUIVALENTS. FINAL LAMP TYPE (STATIC
WHITE OR RGBW) TO BE CONFIRMED
WITH ARCHITECT/OWNER.
7.8 8.5 9.6 106.15.1
C
B
A
E
TL3 TL3
TL3 TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL3
TL6 TL6
TL6 TL6
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL1
TL1
TL1
TL1
TL1
TL1
TL1
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2
TL2TL2TL2
TL2TL2TL2
TL6
TL6
TL6
TL9
TL9
TL9 TL9
TL9
TL9
TL9
TL9
TL8
TL8
TL8
TL8
TL7
TL7
TL7NIC
NIC
NIC
XTR
MIRROR BALL
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M E1.3
ELECTRICAL THIRD
FLOOR NEW
CONSTRUCTION
THEATRICAL PLAN
CEG
AMS
PGW
DRAWING NOTES:
A. PROVIDE ONE (1) ETC NET PORT AT EACH
EXISTING CIRCUIT DISTRIBUTION
POSITION. FIELD VERIFY QUANTITY.
B. PROVIDE ALL THEATRICAL FIXTURES
WITH POWER INPUT, CLAMP, SAFETY,
AND 10' DMX CABLE.
CBCB
CB CB
C
C
C
C1
C1
C1
C
C1
C
C
C
C3
OS1 OS1
OS1 OS1
OS1
C3
C3
C3
7.1
D
7.8 8.5 9.6 106.15.1
C
B
A
E
LL6
LL5
LH3
IQ48(2)
IQ48(1)
DdR6
EDBK
XTR XTR
XTR
STAGE
DIMMER FEED
HOUSE
DIMMER FEED
EXISTING WIRE
TROUGH
MINI DIN RAIL ENCLOSURE
DMX EMERGENCY BYPASS (ABOVE)
EQUIPMENT RACK
NIC
NIC
NIC
XTR
XTR
XTR
XTR
XTR XTR
XTR
XTR
LLA
LL7
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
TL4 TL4 TL4
TL4 TL4 TL4
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k
F1 k k k k k k k k k
TL5
(E) (E) (E)
(E)
(E)
(E)
(E)
(E)
(E)
(E) (E) (E)
(E)
TL2 TL2 TL2
TL2 TL2 TL2
MULTI PURPOSE
RM
STAGE
C1 m m
C1 m m
(E)
(E) n n n
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M E1.4
ELECTRICAL SECOND
FLOOR NEW
CONSTRUCTION PLAN
- ALTERNATE
CEG
AMS
PGW
KEYED NOTES :
1. MOUNT THEATRICAL LIGHT BAR ON FACE
OF BALCONY AT WOOD TRIM.
THEATRICAL LUMINAIRES SHALL BE
MOUNTED AT MINIMUM 13'- 0" AFF.
2. NEW IQ48 THEATRICAL DIMMER PANELS.
PROVIDE NEW FEEDERS. UTILIZE
EXISTING BREAKER. REFER TO ONE-LINE
DIAGRAMS ON DRAWING E0.1 FOR
ADDITIONAL INFORMATION.
3. ADJUST EXISITING BREAKER TO 400A FOR
NEW LOAD. REFER TO ONE-LINE
DIAGRAMS ON DRAWING E0.1 FOR
ADDITIONAL INFORMATION.
4. NEW DdR6 HOUSE DIMMER PANEL.
CONNECT TO EXISTING FEEDER
MAINTAINED. ANY NEW CONDUIT AND
WIRING TO MATCH EXISTING IN ALL
RESPECTS.
5. NEW EMERGENCY LIGHTING RELAY.
CONNECT TO EXISTING FEEDER
MAINTAINED. ANY NEW CONDUIT AND
WIRING TO MATCH EXISTING IN ALL
RESPECTS.
6. UTILIZE EXISTING SPARE BREAKERS
WITHIN EXISTING PANELS FOR NEW
LOADS INDICATED BY HOMERUNS.
CONTRACTOR TO VERIFY EXISTING
CIRCUITS TO BE UTILIZED. IF NO SPARE
BREAKERS EXIST, PROVIDE NEW 20A/1P
BREAKERS AS REQUIRED TO SUPPORT
ADDITIONAL LOADS.
7. DMX BYPASS AND DIN RAIL PART OF
LIGHTING ALTERNATE. CIRCUITS
REQUIRED ONLY IF ALTERNATE IS
ACCEPTED.
C
C
C1
C1
OS1 OS1
OS1
OS1 OS1
OS1
OS1
OS1
OS1
OS1
7.1
D
7.8 8.5 9.6 106.15.1
C
B
A
E
XTR
XTR
XTR
XTR
XTR
XTR XTR XTR XTR
XTRXTRXTRXTR
XTR XTR XTR XTR
XTRXTRXTRXTR
NIC
NIC
NIC
F1 F1 F1 F1 F1 F1 F1 F1 F1
F1 F1 F1 F1 F1 F1 F1 F1 F1
F1 F1 F1 F1 F1 F1 F1 F1 F1
F1 F1 F1 F1 F1 F1
F2
F2
F2
F2
F2
F3
F3
F3
F3
F3
F3F1F1
F1F1
F1F1
F1F1
F1F1
F1F1
F1F1
F1F1
F1F1
F1F1
F1F1
F4
F4
F4 F4 F4
F4
F4
F5
F5
F4F4
F4F4
F4
F4 F4
F4 F4
F5 F5
F5 F5
F5
F5
F6
F6
(E)
(E)
(E)
(E) (E) (E) (E) (E)
(E) (E) (E) (E)(E)
(E)
(E)
(E)
(E)
(E) (E)
(E)(E)
STAGE
BALCONY
(TYP.)
MULTI PURPOSE
RM
f fff c c c c c c c c c c c c c c c c c c d d d d d d d d d d d d d d d a a a a a b b b b b baa aa aa aa aa aa aa aa aa aa aa h h i i h i h j j j j hh ii i h h i i j j j j n n ff ff g gg g g ggg n n a,b,c,d a,b,c,d a,b,c,d a,b,c,d
AS NOTED
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M E1.5
ELECTRICAL THIRD
FLOOR NEW
CONSTRUCTION PLAN
- ALTERNATE
CEG
AMS
PGW
KEYED NOTES :
1. REPLACE EXISTING LAMPING WITH LED
EQUIVALENTS. FINAL LAMP TYPE (STATIC
WHITE OR RGBW) TO BE CONFIRMED
WITH ARCHITECT/OWNER.
THEATRICAL LIGHTING FIXTURE SCHEDULE
TYPE
TL1
TL2
TL3
TL4
TL5
TL6
TL7
TL8
TL9
NOTES:
1. PROVIDE 1 EDSION TO TRU1 AND/OR POWERCON FEED CABLE FOR EACH LIGHITNG DISTRIBUTION LOCATION BASED ON THE FIXTURE TYPE BEING FED FROM THAT LOCATION.
DESCRIPTION
COLORSOURCE CYC
COLORSOURCE FRESNEL V MAX
COLORSOURCE SPOT V
19 DEGREE
COLORSOURCE SPOT V
36 DEGREE
COLORSOURCE SPOT V
15 DEGREE-30 DEGREE ZOOM
COLORSOURCE SPOT JR DEEP BLUE
SELADOR D22 SELL20 LUSTER PORTABLE
HIGH END MEGAPIX
LONESTAR
MANUFACTURER
[ETC]
#CSCYC-400SC-400CC-DPJ-10/CD10-DMX
[ETC]
#CSFRESVMAXMV-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOTVMVS-419EDLT-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOTVMVS-436EDLT-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOTVMVS-41530LT-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOTJRDB2550-400SC-400CC-DPJ-10-CD10-DMX
[ETC]
#SELD22L-400CC-400SC
[ETC]
#MP-MI-MP-TH-T1J-10-MEGA-CLW-400SC-CD10-DMX
[ETC]
#LS-P-T1PA-A-MEGA-CLW-400SC-CD10-DMX
LAMP TYPE
133 W IN WHITE
COLOR MIXING
4117 LUMENS
208 W IN WHITE
COLOR MIXING
9,293 LUMENS
197 W IN WHITE
COLOR MIXING
8,308 LUMENS
197 W IN WHITE
COLOR MIXING
8,308 LUMENS
197 W IN WHITE
COLOR MIXING
8,308 LUMENS
147 W IN WHITE
COLOR MIXING
5,426 LUMENS
56.8W IN WHITE
COLOR MIXING
1,479 LUMENS
450W IN WHITE
COLOR MIXING
10,000 LUMENS
550W
6500K
17,000 LUMENS
CONTROL
DMX
DMX
DMX
DMX
DMX
DMX
DMX
DMX
DMX
VOLTAGE
100-23VAC
100-240VAC
100-240VAC
100-240VAC
100-240VAC
100-240VAC
100-240VAC
100-240V
100-240V
FIXTURE
WATTAGE
133 W
208 W
197 W
197 W
197 W
147 W
57W
450W
550W
REMARKS
PROVIDE WITH CLAMP, SAFETY CABLE, 10' DMX CABLE,
10' PWRCON TO PWRCON JUMPER
PROVIDE WITH CLAMP, SAFETY CABLE, 10' DMX CABLE,
10' TRU1 TO TRU1 JUMPER
PROVIDE WITH CLAMP, SAFETY CABLE, 10' DMX CABLE,
10' TRU1 TO TRU1 JUMPER
PROVIDE WITH CLAMP, SAFETY CABLE, 10' DMX CABLE,
10' TRU1 TO TRU1 JUMPER
PROVIDE WITH CLAMP, SAFETY CABLE, 10' DMX CABLE,
10' TRU1 TO TRU1 JUMPER
PROVIDE WITH CLAMP, SAFETY CABLE, 10' DMX CABLE,
10' PWRCON TO PWRCON JUMPER
PROVIDE WITH CLAMP, SAFETY CABLE, YOKE MOUNT,
AND EDISON MOLDED PLUG
PROVIDE WITH MEGACLAW CLAMP, SAFTEY CABLE,
10' DMX CABLE, 10' TRU1 TO TRU1 JUMPER
PROVIDE WITH MEGACLAW CLAMP, SAFTEY CABLE,
10' DMX CABLE, 10' TRU1 TO TRU1 JUMPER
BASE LIGHTING FIXTURE SCHEDULE
TYPE
F1
F2
F3
F4
F5
F6
C1
NOTES:
1. ALL 0-10VOLT LED DIMMING DRIVERS SHALL MEET THE REQUIREMENTS OF IEC 60929 AND SHALL HAVE AN ISOLATED 0-10VDC CONTROL CIRCUIT.
2. WHERE N/E IS NOTED, PROVIDE FIXTURE WITH TWO (2) DRIVERS. ONE DRIVER SHALL BE POWERED FROM THE NORMAL CIRCUIT AND ONE SHALL BE POWERED FROM THE EMERGENCY CIRCUIT.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMOTE DRIVER LOCATIONS. COORDINATE DRIVER LOCATIONS WITH THE ARCHITECT. PROVIDE WIRE SIZE IN ACCORDANCE
WITH MANUFACTURER’S RECOMMENDATIONS. DO NOT EXCEED MANUFACTURER’S RECOMMENDATIONS FOR DISTANCE.
DESCRIPTION
4" RECESSED LED ROUND DOWNLIGHT, 20 GAUGE GALVANIZED STEEL,
WITH SHALLOW HOUSING, 1500 LUMENS, MEDIUM BATWING 60° LIGHT DISTRIBUTION,
AND WHITE TRIM FINISH
4" RECESSED LED ROUND DOWNLIGHT, 20 GAUGE GALVANIZED STEEL,
WITH SHALLOW HOUSING, 1000 LUMENS, MEDIUM BATWING 60° LIGHT DISTRIBUTION,
AND WHITE TRIM FINISH
4" RECESSED LED ROUND DOWNLIGHT, 20 GAUGE GALVANIZED STEEL,
WITH SHALLOW HOUSING, 2000 LUMENS, MEDIUM BATWING 60° LIGHT DISTRIBUTION,
AND WHITE TRIM FINISH
6" RECESSED LED DOWNLIGHT, 20 GAUGE MINIMUM COLD-ROLLED STEEL, GALVANIZED STEEL,
AND ALUMINUM HOUSING, 4000 LUMENS, 40° LIGHT DISTRIBUTION,
AND WHITE TRIM FINISH
6" RECESSED LED DOWNLIGHT, 20 GAUGE MINIMUM COLD-ROLLED STEEL, GALVANIZED STEEL,
AND ALUMINUM HOUSING, 3000 LUMENS, 40° LIGHT DISTRIBUTION,
AND WHITE TRIM FINISH
4" RECESSED LED LINEAR SLOT, EXTRUDED ALUMINUM HOUSING,
STANDARD SNAP IN FLUSH LENS, LAMBERTIAN LOW GLARE LIGHT DISTRIBUTION,
AND WHITE POWDER COAT FINISH
4' SUSPENDED LED LINEAR STRIP, CODE-GUAGE COLD-ROLLED STEEL HOUSING,
STANDARD EFFICIENCY, FLAT DIFFUSED ACRYLIC LENS, LAMBERTIAN LIGHT DISTRIBUTION,
AND BAKED WHITE POLYESTER FINISH
MANUFACTURER
[GOTHAM LIGHTING]
#IVO4S-D-15LM-35K-90CRI-MD-DARK-MVOLT-ZT-NCH-P-
WMR-F
[GOTHAM LIGHTING]
#IVO4S-D-10LM-35K-90CRI-MD-DARK-MVOLT-ZT-NCH-P-
WMR-F
[GOTHAM LIGHTING]
#IVO4S-D-20LM-35K-90CRI-MD-DARK-MVOLT-ZT-NCH-P-
WMR-F
[GOTHAM]
#IVO6-D-40LM-35K-90CRI-40D-DARK-MVOLT-ZT-NCH-P-
WMR-F
[GOTHAM]
#IVO6-D-30LM-35K-90CRI-40D-DARK-MVOLT-ZT-NCH-P-
WMR-F
[ALW]
#LPX-4-R-G9-FN-S[LENGTH]-12-35-90-LG-
V00-N-N-N-N-N-N-N-SW-N-UNV-N-N-DC
[LITHONIA LIGHTING]
#CLX-L48-3000LM-SEF-FDL-MVOLT-GZ1-35K-90CRI-WH
LAMP TYPE
15.7W
3500K, 90CRI
1,475 LUMENS
10.5W
3500K, 90CRI
1,060 LUMENS
22.4W
3500K, 90CRI
1,929 LUMENS
42.8W
3500K, 90CRI
3,889 LUMENS
25.2W
3500K, 90CRI
2,949 LUMENS
10.97W/LF
3500K, 90CRI
1,533 LM/LF
18.5W
3500K, 90CRI
2,531 LUMENS
CONTROL
0.1% DIMMING (0-10V)
0.1% DIMMING (0-10V)
0.1% DIMMING (0-10V)
0.1% DIMMING (0-10V)
0.1% DIMMING (0-10V)
1% DIMMING (0-10V)
1% DIMMING (0-10V)
VOLTAGE
UNV
UNV
UNV
UNV
UNV
UNV
UNV
FIXTURE
WATTAGE
16W
11W
22W
43W
25W
11W/LF
19W
REMARKS
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR TO COORDINATE MOUNTING PRIOR TO INSTALLATION.
CONTRACTOR SHALL COORDINATE ALL REQUIRED MOUNTING ACCESSORIES.
BOTTOM OF FIXTURE TO BE MOUNTED 8'-0" AFF.
NO SCALE
Drawing No.
Drawing Title
Date:
Revisions
Drawn By
Project No.
Checked By
Project Mgr.
Copyright © 2026 RFS Engineering
10967.001
50% Construction Documents
June 19, 2026
Mabel Brown Room Theatrical & House Lighting Upgrades
Keene State College
File Name
Key Plan
Stamp
Scale
229 Main Street Keene, NH 03431 www.rfsengineering.com
24 Federal Street, 3rd Floor, Boston, MA 02110, 617.494.1464 71 Water Street, Laconia, NH 03246, 603.524.4647 82 Hanover Street, Suite 2, Portland, ME 04101, 207.761.4647
Boston, MA | Laconia, NH | Portland, ME
10967 Central Elect 2024.rvt
Jones Architecture, Inc.
10 Derby Square Salem, MA 01970
978.744.5200 www.jonesarch.com
Architect:
/1
/2
:2
:4
P
M E2.1
LIGHTING SCHEDULES
- BASE
CEG
AMS
THEATRICAL LIGHTING FIXTURE SCHEDULE
TYPE
TL1
TL2
TL3
TL4
TL5
TL6
TL7
TL8
TL9
NOTES:
1. PROVIDE 1 EDSION TO TRU1 AND/OR POWERCON FEED CABLE FOR EACH LIGHITNG DISTRIBUTION LOCATION BASED ON THE FIXTURE TYPE BEING FED FROM THAT LOCATION.
DESCRIPTION
COLORSOURCE CYC
COLORSOURCE FRESNEL V MAX
COLORSOURCE SPOT V
19 DEGREE
COLORSOURCE SPOT V
36 DEGREE
COLORSOURCE SPOT V
15 DEGREE-30 DEGREE ZOOM
COLORSOURCE SPOT JR DEEP BLUE
SELADOR D22 SELL20 LUSTER PORTABLE
HIGH END MEGAPIX
LONESTAR
MANUFACTURER
[ETC]
#CSCYC-400SC-400CC-DPJ-10/CD10-DMX
[ETC]
#CSFRESVMAXMV-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOTVMVS-419EDLT-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOTVMVS-436EDLT-400CC-400SC-T1J-10-CD10-DMX
[ETC]
#CSSPOT…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .