1-2026530 Millcreek City Hall L4-L5 Bid Set 10-30-26.pdf

PDF 12 MB Posted

Attached to
Millcreek City Hall L4-L5 Remodel
Solicitation number
MK-BLD26-2
Issued by
Salt Lake County, Moab City, Utah

About this file

Summary of Millcreek City Hall L4-L5 Remodel Bid Set

This bid set document pertains to a general contracting opportunity for the City of Millcreek, Utah, involving the interior build-out of shell space on the fourth and fifth floors of the occupied City Hall located at 1330 East Chambers Avenue. The project scope includes constructing offices, open office areas, and a conference room, with associated fire protection, mechanical, and electrical work. The contract is structured as a single prime, stipulated sum award with a Base Bid covering Level 4 complete build-out and Level 5 Offices 581 and 582, plus an Add Alternate No. 1 for the balance of Level 5. A mandatory prebid meeting and walkthrough is scheduled for Friday, November 6, 2026, at 10:00 a.m. at Millcreek City Hall, City Council Chambers, with attendance being required for bid eligibility. Sealed bids are due at the front reception desk of City Hall by 2:00 p.m. on Thursday, November 12, 2026, and will be publicly opened and read aloud immediately thereafter. Bidding documents became available on November 4, 2026, through the City website, the Utah Public Notice Website, and U3P. The successful bidder must achieve Substantial Completion within 60 calendar days after receiving the Notice to Proceed. Questions and substitution requests must be submitted by email to Kurt Hansen at khansen@millcreekut.gov with a copy to tales.brito@mhtn.com no later than Monday, November 9, 2026, at 12:00 p.m.

The contract requires a bid security deposit of 5 percent and mandates that the successful bidder furnish 100 percent performance and payment bonds. Bidders must meet minimum qualifications as specified in the bidding documents, and the award will be made to the lowest responsive and responsible bidder. Millcreek reserves the right to reject any or all bids submitted. Email and electronic bid submissions will not be accepted. ADA accommodations may be requested by contacting Kurt Hansen at khansen@millcreekut.gov or 801-214-2751.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

MHTN ARCHITECTS, INC.

280 SOUTH 400 WEST

SUITE 250

SALT LAKE CITY, UTAH 84101

PHONE: (801) 595-6700

ARCHITECTURE MECHANICAL ELECTRICAL

LYNK ENGINEERS

324 SOUTH STATE STREET

SUITE 400

SALT LAKE CITY, UT. 84111

Phone: 801.328.5151 www.lynkengineers.com

LYNK ENGINEERS

324 SOUTH STATE STREET

SUITE 400

SALT LAKE CITY, UT. 84111

Phone: 801.328.5151 www.lynkengineers.com

SHEET NUMBER

SEAL

SHEET NAME

REVISIONS:

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATENO.

Original drawing is 30 x 42. Do not scale contents of this drawing.

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

VIEW AND PRINT THIS DRAWING IN COLOR

ISSUE

MHTN PROJECT NO.

Original drawing is 30 x 42. Do not scale contents of this drawing.

D

10/30/2026

/3 /2

:4

:5

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

A

M ill c re e k C it y H a ll.

rv t

MILLCREEK CITY HALL

4TH & 5TH FLOOR REMODEL

OCTOBER 30, 2026

1330 EAST CHAMBERS AVENUE

MILLCREEK, UTAH 84106

BID SET

COVER SHEET

GS000

T

H

T

H F

L O

O R

R E

M O

D E

L

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y H

A L

L

OCTOBER 30, 2026

BID SET

2026530

©2021 MHTN ARCHITECTS, INC.

ABBREVIATIONS

AC AIR CONDITIONING

AFF ABOVE FINISH FLOOR

ALT ALTERNATE

ALUM ALUMINUM

APPROX APPROXIMATE

ARCH ARCHITECTURAL

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BO BOTTOM OF

BOT BOTTOM

BRB BUCKLING RESTRAINED BRACE

BRG BEARING

CB CATCH BASIN

CFMF COLD FORMED METAL FRAMING

CFOI CONTRACTOR FURNISHED OWNER INSTALLED

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CL CENTER LINE

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

CO CLEANOUT, CLEAR OPENING

COL COLUMN

COMM COMMUNICATION

CONC CONCRETE

CONF CONFERENCE

CONST CONSTRUCT, CONSTRUCTION

CONT CONTINUOUS

COORD COORDINATE

CORR CORRIDOR

CTR CENTER

DB DECK BEARING ELEVATION

DEMO DEMOLITION

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL

DIM DIMENSION

DN DOWN

DR DOOR

DTL DETAIL

DWG DRAWING

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELEC ELECTRICAL

ELEV ELEVATOR

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRICAL WATER COOLER

EXP EXPANSION

EXT EXTERIOR

FD FLOOR DRAIN

FEC FIRE EXTINGUISHER CABINET

FIN FINISH

FIN FLR FINISH FLOOR

FLR FLOOR

FT FOOT, FEET

GA GAUGE, GAGE

GI GALVANIZED IRON

GLULAM GLUED-LAMINATED TIMBER

GYP BD GYPSUM BOARD

HVAC HEATING, VENTILATION, AIR CONDITIONING

ID INSIDE DIAMETER

INT INTERIOR

ISO ISOMETRIC

JAN JANITOR

JT JOINT

KD KNOCK DOWN

LAB LABORATORY

LAV LAVATORY

MAINT MAINTENANCE

MAX MAXIMUM

MECH MECHANICAL

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OFOI OWNER FURNISHED OWNER INSTALLED

OFCI OWNER FURNISHED CONTRACTOR INSTALLED

OH OVERHEAD

OH DR OVERHEAD DOOR

OPP OPPOSITE

PERP PERPENDICULAR

PL PLATE, PROPERTY LINE

PLAM PLASTIC LAMINATE

PLBG PLUMBING

PLYWD PLYWOOD

PR PAIR

PREFAB PREFABRICATED

QTY QUANTITY

RD ROOF DRAIN

RE: REFER TO

REINF REINFORCE, REINFORCING

REQD REQUIRED

REF REFRIGERATOR

RM ROOM

RO ROUGH OPENING

RTU ROOF TOP UNIT

RV ROOF VENT

SF SQUARE FEET

SIM SIMILAR

SPEC SPECIFICATION

SQ SQUARE

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENDED

THK THICK, THICKNESS

TO TOP OF

TOB TOP OF BEAM

TOD TOP OF DECK

TOS TOP OF SLAB, TOP OF STRUCTURE

TOW TOP OF WALL

TYP TYPICAL

UNO UNLESS NOTED OTHERWISE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VTR VENT THROUGH ROOF

W/ WITH

W/O WITHOUT

WC WATER CLOSET

WD WOOD

W WIDE FLANGE

WH WATER HEATER

WWF WELDED WIRE FABRIC

XFMR TRANSFORMER

N

GENERAL SYMBOLS

A1011

A101

S 3 1 A X 12 / 33

EL: 100'-0"

VERTICAL ELEVATION

SPOT ELEVATION

DRAWING

REVISION

ROOM NAME

ROOM NUMBER

KEYED NOTES

DOOR NUMBER

SHEET WHERE DRAWN

BUILDING SECTION

WALL SECTION

DETAIL

EXTERIOR ELEVATION

WINDOW TYPE

INTERIOR WALL TYPE

REVISION NUMBER INTERIOR ELEVATION

SEE PLUMBING, MECHANICAL AND ELECTRICAL FOR DISCIPLINE SYMBOLS

GRID REFERENCE MARK

A1 Starts at lower left corner Number Horizontal Letters Vertical

MHTN SHEET NUMBER

Sheet Number Sequencce Sheet Type Discipline

ACT1

ROOM VOLUME / AREA

CEILING TAG

SHEET WHERE DRAWN

SHEET WHERE DRAWN

SHEET WHERE DRAWN

SHEET WHERE DRAWN

A 1 01

A101

SIM

CALLOUT

SHEET WHERE DRAWN

B

A

1 2

CASEWORK TYPE

DEPTH

HEIGHT

WIDTH

LEVEL

ELEVATION

A101

SIM

A101

SIM

A101

SIM

A101

SIM

QUALIFIER, IF NEEDED

FIRE RATING, IF NEEDED

CORE THICKNESS

CORE MATERIAL

THICKNESS (MIL), IF OTHER

THAN 30 MIL (20 GA)

STUD SPACING,

IF OTHER THAN 16" OC

E1

EXTERIOR WALL TYPE

ROOF TYPE

FLOOR TYPE

HEIGHT & STC

ST2 SIGNAGE TYPE

ROOM

150 SF

10'-0"

CEILING TYPE TAG

NORTH ARROW

PLAN NORTH

TRUE NORTH

CONCRETE EARTHGYPSUM

BOARD

RIGID/SEMI/

SAFING

INSULATION

MASONRY

BRICK

CONCRETE

MASONRY UNIT

HARDWOOD

EIFS

STONE

STEEL

GRAVEL BATT

INSULATION

MATERIALS

WOOD

FRAMING

PRECAST

BLOCKING

SHEET NUMBER

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

SEAL

DESCRIPTIONDATENO.

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT LAST

REVISION DATE.

CONSULTANTS

VICINITY MAP

INDEX TO DRAWINGS -

SHEET NAME

DESCRIPTIONDATENO.

ISSUED

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

VIEW AND PRINT THIS DRAWING IN COLOR

ISSUE

MHTN PROJECT NO.

Original drawing is 30 x 42. Do not scale contents of this drawing.

LYNK ENGINEERS

324 SOUTH STATE STREET

SUITE 400

SALT LAKE CITY, UT. 84111

Phone: 801.328.5151 www.lynkengineers.com

MECHANICAL

LYNK ENGINEERS

324 SOUTH STATE STREET

SUITE 400

SALT LAKE CITY, UT. 84111

Phone: 801.328.5151 www.lynkengineers.com

ELECTRICAL

10/30/2026

/3 /2

:4

:5

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

A

M ill c re e k C it y H a ll.

rv t

GS001

T

H

T

H F

L O

O R

R E

M O

D E

L

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y H

A L

L

MILLCREEK CITY HALL

4TH & 5TH FLOOR REMODEL

OCTOBER 30, 2026

1330 EAST CHAMBERS AVENUE

MILLCREEK, UTAH 84106

BID SET

BID SET

INDEX SHEET

OCTOBER 30, 2026

BID SET

2026530

©2021 MHTN ARCHITECTS, INC.

GENERAL

GS000 COVER SHEET

GS001 INDEX SHEET

GS100 LIFE SAFETY PLANS

ARCHITECTURAL

AS100 DEMOLITION PLANS

AS104 FOURTH FLOOR PLAN/RCP

AS105 FIFTH FLOOR PLAN/RCP (BASE AND ADD ALTERNATE)

FIRE PROTECTION

FP001 FIRE SUPPRESSION COVER SHEET

FP104 FOURTH FLOOR FIRE SUPPRESSION PLAN

FP105 FIFTH FLOOR FIRE SUPPRESSION PLAN

MECHANICAL

ME001 MECHANICAL COVER SHEET

ME501 MECHANICAL DETAILS

ME601 MECHANICAL SCHEDULES

MD104 FOURTH FLOOR MECHANICAL DEMOLITION PLAN

MD105 FIFTH FLOOR MECHANICAL DEMOLITION PLAN

MH104 FOURTH FLOOR MECHANICAL PLAN

MH105 FIFTH FLOOR MECHANICAL PLAN

MH114 FOURTH FLOOR MECHANICAL PIPING PLAN

MH115 FIFTH FLOOR MECHANICAL PIPING PLAN

ELECTRICAL

EE001 ELECTRICAL COVER SHEET

EE501 ELECTRICAL DETAILS

EE601 ELECTRICAL SCHEDULES

EE602 ELECTRICAL SCHEDULES

EE701 TYPICAL MOUNTING HEIGHT DETAILS

ED104 4TH & 5TH FLOOR CEILING DEMOLITION PLAN

EP104 4TH & 5TH FLOOR POWER PLAN

EP615 PANEL SCHEDULES

EL104 4TH & 5TH FLOOR LIGHTING PLAN

BASE BID

• See Specification Section 012300 “Alternates.”

• Base Bid Item 1: All Work indicated on the Drawings for the Fourth Floor.

• Base Bid Item 2: All Work indicated on the Drawings for

Fifth Floor Offices 581 and 582. Include all Work required to make Offices 581 and 582 complete and usable if Add Alternate No. 1 is not accepted, including:

• The path of travel to the existing corridor and stair

• Mechanical, electrical, fire protection and data routing through the alternate area

• Separation at the alternate boundary

ADD ALTERNATE NO. 1

• All Work indicated within the hatched Add Alternate boundary on the Fifth Floor, on sheets AS105, FP105, MD105, MH105, ED104, EP104, and EL104, including Offices 584, 585 and 586, Open Office 583, and Conference Room 580

• Includes the associated architectural, fire protection, mechanical and electrical work and the Add Alternate demolition indicated.

F E

C

FE

F E

C

TT

T

T

T

F E

C

FE

T

T

T

T

T

F E

C

FEC

RE: Original build life safety drawings for full building exiting, fire rating, and overall code compliance. Occupancy load for new office area already accounted for in the original build.

Exit Width Capacity: Exit width capacities are based on 0.3" per occupant at stairways and 0.2" per occupant at other means of egress components.

LIFE SAFETY PLAN GENERAL NOTES

9331 SF

150 GSF

BUSINESS

AREA FUNCTION (IBC TABLE 1004.1.2)

ASSEMBLY, UNCON

BUSINESS

MECH

EXIT

300 60

EXIT

170 34

220 SF

300 GSF

MECH

SHAFT

80 SF

15 GSF

ASSEMBLY, UNCON

( 86 FT )

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

110 SF

300 GSF

STORAGE

EXIT

300 60

EXIT

170 34

SHAFT

( 87 FT )

OFFICE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

OFFICE

OFFICE

OFFICE

LEGEND - LIFE SAFETY

EXIT

335 67"

OCCUPANCY GROUP

OCCUPANT LOAD

OCCUPANT LOAD FACTOR

GROSS: GSF NET: NSF

SQUARE FOOTAGE

EXIT LOAD

EXIT WIDTH PROVIDED

EXIT CAPACITY

TRAVEL DISTANCE

(75 FT)

AREA USE

150 SF 7 NSF

38A-3

FIRE BARRIER - 2 HOUR

FIRE EXTINGUISHER + CABINET

SEMI-RECESSED

FIRE RESISTANT - 2 HOUR

FIRE WALL - 3 HOUR

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

09/04/2026

/3 /2

:4

:5

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

A

M ill c re e k C it y H a ll.

rv t

LIFE SAFETY

PLANS

GS100

OCTOBER 30, 2026

BID SET

2026530

T

H

T

H F

L O

O R

R E

M O

D E

L

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y H

A L

L

©2021 MHTN ARCHITECTS, INC.

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/4" = 1'-0"

FOURTH FLOOR LIFE SHELL SPACE SAFETY PLAN

N

SCALE:

4' - 0" 8' - 0" 16' - 0"

1/4" = 1'-0"

FIFTH FLOOR SHELL SPACE LIFE SAFETY PLAN

N

M

F E

C

FE

SD

F E

C

CG

C G

CG

FE

SD

1 2 3

A

B

A.8

A.1

AS100A4

AS100B4

1 2 3

A

B

A.8

A.1

AS100D4

LEGEND - DEMOLITION

REMOVE & SALVAGE

DOOR & FRAME

AREA OF NO WORK

EXISTING TO REMAIN

WALLS & OTHER ITEMS

TO BE DEMOLISHED

NOTE: WHERE WALLS AND OTHER ITEMS ARE

SHOWN WITH DASHED LINES, WHETHER

KEYNOTED OR NOT, REMOVE THESE ITEMS TO

THE EXTENT INDICATED AND AS REQUIRED BY

NEW CONSTRUCTION.

Protection: Protect existing construction to remain from damage during demolition and new construction work. Repair any damage resulting from this work.

Protect in-place, existing mechanical, plumbing and electrical systems above ceilings that are not shown to be removed. This includes, but is not limited to: network cabling, coax cabling, conduits, piping, ductwork, etc.

Site Access: Coordinate phased access to the site with the Owner, including times of restricted access.

Coordination: Coordinate extent of walls to be removed with architectural floor plan(s).

Walls: Where walls are demolished, clean and repair newly exposed surfaces (gypsum and concrete) to match adjacent wall finish.

Salvage: Review with the owner, casework, furniture, equipment and wall mounted display surfaces left behind after owner move out, that are not shown on drawings. Identify as either salvage or to be disposed of by contractor.

DEMOLITION GENERAL NOTES

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

09/04/2026

/3 /2

:4

:5

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

A

M ill c re e k C it y H a ll.

rv t

DEMOLITION

PLANS

AS100

OCTOBER 30, 2026

BID SET

2026530

T

H

T

H F

L O

O R

R E

M O

D E

L

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y H

A L

L

©2021 MHTN ARCHITECTS, INC.

SCALE:

2' - 0" 4' - 0" 8' - 0"

1/4" = 1'-0"

SHELL SPACE FOURTH FLOOR DEMO

SCALE:

2' - 0" 4' - 0" 8' - 0"

1/4" = 1'-0"

SHELL SPACE FIFTH FLOOR ADD ALTERNATE DEMO 1

SCALE: 1/4" = 1'-0"

A4

LEVEL 4 NORTH DOOR

SCALE: 1/4" = 1'-0"

B4

LEVEL 4 SOUTH DOOR

SCALE: 1/4" = 1'-0"

D4

LEVEL 5 SOUTH DOOR - ADD ALTERNATE DEMO 1

M

C

F E

C

/4

2J

/4

2J

46/42N

46/42N

46/42N

/4

2J

46/42N

46/42N

C G

C G

CG

C G

C G

C G

C G

F E

C

TT

T

T

T

C

CG

1 2

A

B

A.8

A.1

16'-7" 11'-2"

1'-2"

2' -1

2'-1"

2'-1"

'-0

11'-8 3/4" 3'-0"

1' -4

/2

8'

-1

9' -6

2' -4

/8

3'-0"

16'-7" 11'-2"

AS104B4

A4

C4

D4

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

OTS

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

OFFICE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

OFFICE

OFFICE

AS104

D5

AS104

D5

099123.A00

096513.A01

OPEN TO

BEYOND

096513.A01

099123.A00

AS104

D5

AS104

D5

OPEN TO

BEYOND

AS104

D5

AS104

D5

099123.A00

096513.A01

OPEN TO

BEYOND9'

-4

4'-5"

9' -4

"OPEN TO

BEYOND

099123.A00

096513.A01

CONT. JOINT SEALANT AROUND

PERIMETER OF FRAME, BOTH

SIDES (TYP)

SCHEDULED WALL

DOUBLE STUD JAMB

2"

HOLLOW METAL FRAME

DOOR PER DOOR SCHEDULE

SCHEDULED FINISH

SCHEDULED FINISH

WOOD DOOR

2"

CONT. JOINT SEALANT AT

PERIMETER OF FRAME,

BOTH SIDES (TYP)

SCHEDULED WALL

METAL STUD BOX

BEAM HEADER

HOLLOW METAL FRAME

SCHEDULED FINISH

TRANSOM GLAZING

FLOOR PLAN GENERAL NOTES

References to sheets below are provided to aid in navigating the drawings.

RE: E4/AS102 & E5/AS102 for metal stud size.

RE: Mechanical for return and supply grille type.

RE: Electrical for lighting types as well as power and data locations.

Owner Provided Equipment: Furniture layout for visualization only. Layout of owner provided equipment, tables and chairs, etc... must be done to comply with accessible clear floor space and other accessibility requirements of ICC A117.1-2017.

A minimum of 5% of the work surfaces to be accessible per IBC 1109.11.

Ceiling Grid/Panel Alignment: The design intent of the Reflected Ceiling Plans is center ceiling grids or acoustical panels between walls in both directions, or to center grids in one direction, panels in the other. If the grid does not comply with the design intent, then coordinate with Architect to adjust the ceiling layout prior to installation.

Seismic Design Category: D: Heavy-duty suspension system required / Refer to Specifications.

Seismic Bracing: Rigid bracing required at ceilings (ASTM E580)

Walls to Deck: Extend all walls to deck, including all components of the wall assembly, UNO.

Fire Sprinklers: Center sprinkler heads in acoustical panels; run in straight lines in orthogonal, rectangular spaces.

Electrical, Mechanical and other Devices: Center in acoustical panels. Coordinate feature lighting layout with Architect prior to rough-in.

Keynotes: Not all keynotes apply to this sheet.

REFLECTED CEILING PLAN GENERAL NOTES

LEGEND - FLOOR PLAN/RCP

CORNER GUARD

NOTE: PROVIDE ITEMS INDICATED IN THE LEGEND

IN THE QUANTITIES SHOWN ON THE PLAN. REFER

TO MECHANICAL & ELECTRICAL DRAWINGS FOR

LIGHT FIXTURES AND GRILLES

ACP1 - 24" X 24" ACOUSTICAL CEILING PANEL

CPT1 - 1m (MANUFACTURER: MILLIKEN, STYLE: LOW

COUNTRY - ESTUARY, COLOR: EST 124-259)

ACP2 - 24" X 48" ACOUSTICAL CEILING PANEL

(MANUFACTURER: ARKTURA, STYLE: VAPOR BLOOM)

WGP - WOOD GRILLE PANEL (OWNER PROVIDED,

CONTRACTOR INSTALLED)

2" 2'-0"

2" 3'-0"

2" 5'-6"

WOOD DOOR

HOLLOW METAL

FRAME

T01

E5

AS104

E4

AS104

2" 3'-0"

2"

E5

AS104

E4

AS104

7' -0

2"

2' -0

2"

9' -4

4" 6'

-8

2" 2'

-0

2"

T01 T01T01

CLEAR TEMPERED

FLOAT GLASS

6" 2'-0" 6"

3' -0

6"

6" 2'-0" 6"

3' -0

6"

T01T01

LINE OF FLOOR

STRUCTURE

CONTINUOUS STEEL

RUNNER SET IN BED OF

CONTINOUS ACOUSTIC

SEALANT

5/8" GYPSUM, EACH

SIDE

CONTINUOUS

ACOUSTICAL SEALANT

OVER BUTYL BACKER ROD

BATT INSULATION

3 5/8"

METAL STUD

LINE OF STRUCTURE

DEFLECTION TRACK

5/8" GYPSUM, EACH SIDE

CONTINUOUS

ACOUSTICAL SEALANT

BATT INSULATION

3 5/8"

METAL STUD

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

09/04/2026

/3 /2

:4

:5

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

A

M ill c re e k C it y H a ll.

rv t

FOURTH FLOOR

PLAN/RCP

AS104

OCTOBER 30, 2026

BID SET

2026530

T

H

T

H F

L O

O R

R E

M O

D E

L

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y H

A L

L

©2021 MHTN ARCHITECTS, INC.

SCALE:

2' - 0" 4' - 0" 8' - 0"

1/4" = 1'-0"

SHELL SPACE FOURTH FLOOR PLAN

SCALE:

2' - 0" 4' - 0" 8' - 0"

1/4" = 1'-0"

SHELL SPACE FOURTH FLOOR RCP

SCALE: 1/4" = 1'-0"

B4

L4 OPEN OFFICE WEST

SCALE: 1/4" = 1'-0"

A4

L4 OPEN OFFICE NORTH

SCALE: 1/4" = 1'-0"

C4

L4 OPEN OFFICE SOUTH

SCALE: 1/4" = 1'-0"

D4

L4 OPEN OFFICE EAST

SCALE: 3" = 1'-0"

E4

DOOR JAMB

SCALE: 3" = 1'-0"

E5

DOOR HEAD

N

N

SCALE: 1/4" = 1'-0"

D5

OFFICE FRONT

KEYNOTES

096513.A01 RESILIENT BASE

099123.A00 INTERIOR PAINTING

(MANUFACTURER: ROPPE, STYLE: PINNACLE, COLOR: 125 FIG)

(MANUFACTURER: SHERWIN-WILLIAMS, STYLE: LATEX, LOW-

VOC EGGSHELL, COLOR: WHITE OC-151)

NOTE: Finishes above apply to all offices

SCALE: 3" = 1'-0"

WALL BASE DETAIL

SCALE: 3" = 1'-0"

WALL HEAD DETAIL

F

C

CG

C G

CG

C G

C G

T

T

T

T

T

CG

F E

C

C

J J

T

T

CG

1 2

A

B

A.8

A.1

16'-7" 11'-6"

2'-0"

AS105

A3

C3

AS105C4

OFFICE

OFFICE

ADD ALTERNATE #1

9'-1" 9'-6" 9'-6"

2'-0" 2'-0" 2'-0"

'-0

2'-0" 2'-0"

1'-4"

OFFICE

OFFICE

OFFICE

CONFERENCE ROOM

OPEN OFFICE

583B3

1' -4

9' -6

B4

AS105

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

ACP1

9'-6"

OFFICE

OFFICE

OPEN OFFICE

ADD ALTERNATE #1

4' -0

10'-0"

20'-0"

'-0

ACP2

8'-6"

OFFICE

OFFICE

OFFICE

ACP1

9'-6"

CONFERENCE ROOM

ACP1

9'-6"

WGP

8'-0"

E5

AS105

099123.A00096513.A01

AS104

D5

AS104

D5

AS104

D5

OPEN TO

BEYOND

AS104

D5

AS104

D5

AS104

D5

9' -4

099123.A00

OPEN TO

BEYOND

FLOOR PLAN GENERAL NOTES

References to sheets below are provided to aid in navigating the drawings.

RE: E4/AS102 & E5/AS102 for metal stud size.

RE: Mechanical for return and supply grille type.

RE: Electrical for lighting types as well as power and data locations.

Owner Provided Equipment: Furniture layout for visualization only. Layout of owner provided equipment, tables and chairs, etc... must be done to comply with accessible clear floor space and other accessibility requirements of ICC A117.1-2017.

A minimum of 5% of the work surfaces to be accessible per IBC 1109.11.

Ceiling Grid/Panel Alignment: The design intent of the Reflected Ceiling Plans is center ceiling grids or acoustical panels between walls in both directions, or to center grids in one direction, panels in the other. If the grid does not comply with the design intent, then coordinate with Architect to adjust the ceiling layout prior to installation.

Seismic Design Category: D: Heavy-duty suspension system required / Refer to Specifications.

Seismic Bracing: Rigid bracing required at ceilings (ASTM E580)

Walls to Deck: Extend all walls to deck, including all components of the wall assembly, UNO.

Fire Sprinklers: Center sprinkler heads in acoustical panels; run in straight lines in orthogonal, rectangular spaces.

Electrical, Mechanical and other Devices: Center in acoustical panels. Coordinate feature lighting layout with Architect prior to rough-in.

Keynotes: Not all keynotes apply to this sheet.

REFLECTED CEILING PLAN GENERAL NOTES

LEGEND - FLOOR PLAN/RCP

CORNER GUARD

NOTE: PROVIDE ITEMS INDICATED IN THE LEGEND

IN THE QUANTITIES SHOWN ON THE PLAN. REFER

TO MECHANICAL & ELECTRICAL DRAWINGS FOR

LIGHT FIXTURES AND GRILLES

ACP1 - 24" X 24" ACOUSTICAL CEILING PANEL

CPT1 - 1m (MANUFACTURER: MILLIKEN, STYLE: LOW

COUNTRY - ESTUARY, COLOR: EST 124-259)

ACP2 - 24" X 48" ACOUSTICAL CEILING PANEL

(MANUFACTURER: ARKTURA, STYLE: VAPOR BLOOM)

WGP - WOOD GRILLE PANEL (OWNER PROVIDED,

CONTRACTOR INSTALLED)

SYMBOL LEGEND:

B - SEISMIC CLIP

X - PERIMETER WIRES

X - HANGER WIRES

ATTACHED WALL

U N

A T

T A

C H

D

W

A

LL

CEILING PLAN

B B B X X X

B

B

B

B

B

B

B

B

X X

X X

X X

X X

X

X

X

X

X

X

X

X X X X

PERIMETER WIRE

HANGER WIRE

LATER FORCE BRACING

REQUIRED, THIS LOCATION

ONLY

X

45.0°

.0

15°

45 45

VERTICAL

COMPRESSION STRUT

12 GA. SPLAY WIRE IN

PLANE OF EACH

COMPONENT

MAIN RUNNER

CROSS RUNNERNOTE: SPLAY WIRES WITH STRUT TO BE 12'-0" O.C.

EACH DIRECTION - THE FIRST POINT OF

BRACING TO BE WITHIN 6'-0" FROM EACH WALL

4" MAXTYP

09ADTCL001

09ADTCL009

12 GA. PERIMETER

WIRE

SEISMIC CLIP

RUNNER

7/8" WALL MOLDING

NOTE: FOR UNATTACHED WALL CONDITION

TYP

8" MAX

7/8"

3/4"

09ADTCL010

NOTE: FOR ATTACHED WALL CONDITION

12 GA. PERIMETER

WIRE

SEISMIC CLIP

RUNNER

7/8" WALL MOLDING

TYP

8" MAX

7/8"

CONCRETE AS SCHEDULED

ROPPE #24 REDUCER STRIP OR

EQ IN THE COLOR 125 FIG

CARPET FINISH AS

SCHEDULED

OPEN TO

BEYOND

OWNER PROVIDED SIGN. VERIFY

POSITION W/ ARCHITECT PRIOR TO

INSTALATION

096513.A01099123.A00

ACOUSTICAL CEILING

PANEL SYSTEM

EDGE TRIM

PROVIDE SHOP CUT-

OUT FOR GROMMETS

(2)

HEFELE 1100 LBS

SUPPORT BRACKET

LAMINATE

COUNTERTOP WITH

WOOD EDGE

2' -6

2'-6"

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

09/04/2026

/3 /2

:4

:5

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

A

M ill c re e k C it y H a ll.

rv t

FIFTH FLOOR

PLAN/RCP (BASE

AND ADD

ALTERNATE)

AS105

OCTOBER 30, 2026

BID SET

2026530

T

H

T

H F

L O

O R

R E

M O

D E

L

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y H

A L

L

©2021 MHTN ARCHITECTS, INC.

SCALE:

2' - 0" 4' - 0" 8' - 0"

1/4" = 1'-0"

SHELL SPACE FIFTH FLOOR PLAN

SCALE:

2' - 0" 4' - 0" 8' - 0"

1/4" = 1'-0"

SHELL SPACE FIFTH FLOOR RCP

SCALE: 1/4" = 1'-0"

A3

L5 OPEN OFFICE NORTH

SCALE: 1/4" = 1'-0"

C3

L5 OPEN OFFICE SOUTH

SCALE: 1/4" = 1'-0"

C4

N. CORRIDOR

N

N

KEYNOTES

096513.A01 RESILIENT BASE

099123.A00 INTERIOR PAINTING

(MANUFACTURER: ROPPE, STYLE: PINNACLE, COLOR: 125 FIG)

(MANUFACTURER: BENJAMIN MORE, STYLE: LATEX, LOW-VOC

EGGSHELL, COLOR: WHITE OC-151)

NOTE: Finishes above apply to all offices

SCALE: 1 1/2" = 1'-0"

D3

TYPICAL CEILING DETAIL

SCALE: 1 1/2" = 1'-0"

D4

DETAIL

SCALE: 1 1/2" = 1'-0"

E4

TYPICAL DETAIL

SCALE: 1 1/2" = 1'-0"

E3

TYPICAL DETAIL

SCALE: 3" = 1'-0"

D5

FLOOR - CARPET TO CONCRETE

SCALE: 1/4" = 1'-0"

B3

L5 OPEN OFFICE EAST

SCALE: 1 1/2" = 1'-0"

E5

CEILING DETAIL

SCALE: 3/4" = 1'-0"

B4

COUNTER TOP

8827670

JARRETT W.

CAPSTICKS

T

A T E

OF

U T

A H

L

IC

E N S E D

PR

OFE

SSIONAL

EN

G

IN

E E R

324 S. State St., Suite 400 Salt Lake City, UT 84111

800-678-7077 801-328-5151 www.lynkengineers.com

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

L Y

N K

E N

G

IN

E E

R S

J O

B

-0

2026-09-04

/3 /2

:3

:3

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

M

M ill c re e k C it y H a ll.

rv t

FIRE SUPPRESSION

COVER SHEET

FP001

OCTOBER 30, 2026

BID SET

2021535

H A

L L

S

H E

L L

S P

A C

E

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y

©2021 MHTN ARCHITECTS, INC.

DEFINITIONS

NOTE: ALL DEFINITIONS MAY NOT BE USED.

INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR

SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND

SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN",

"NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE

REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.

DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE

ENGINEER", AND SIMILAR PHRASES.

APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION

ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE

ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY

CONDITIONS.

FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS."

INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE

ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING,

WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS."

PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE

INTENDED USE."

INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-SUBCONTRACTOR, FOR PERFORMANCE OF A

PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY

ARE ENGAGED TO PERFORM.

FIRE PROTECTION SHEET INDEX

FP001 FIRE SUPPRESSION COVER SHEET

FP104 FOURTH FLOOR FIRE SUPPRESSION PLAN

FP105 FIFTH FLOOR FIRE SUPPRESSION PLAN

1. MODIFY THE EXISTING BUILDING FIRE PROTECTION SYSTEM AS NECESSARY TO PROVIDE

COMPLETE COVERAGE FIRE PROTECTION SYSTEMS FOR THE AREAS OF WORK. EXCEPT

WHERE REQUIRED OTHERWISE, THE FIRE PROTECTION SYSTEMS SHALL BE COMPLETE

COVERAGE AUTOMATIC WET PIPE SPRINKLER SYSTEM, IN ACCORDANCE WITH NFPA 13.

2. COORDINATE INSTALLATION LOCATION OF SPRINKLER HEADS WITH ALL OTHER DEVICES

INSTALLED IN THE CEILINGS AND WITH THE LATEST REFLECTED CEILING PLANS.

3. CENTER SPRINKLER HEADS IN LAY-IN CEILING TILES.

4. PROVIDE SPRINKLERS BENEATH HVAC DUCT OBSTRUCTIONS OVER 48" WIDE, PER NFPA 13;

REFER TO HVAC DRAWINGS TO DETERMINE OCCURRENCE(S) OF DUCT OBSTRUCTIONS OVER

48" WIDE.

5. COORDINATE ALL SPRINKLER ALARM/SUPERVISORY TIE-IN CONNECTIONS WITH FIRE ALARM

SYSTEM CONTRACTOR. MONITOR ALL FIRE SPRINKLER SYSTEM VALVES ON THE FIRE ALARM

SYSTEM.

6. PROVIDE WIRE GUARDS OVER SPRINKLERS WITHIN MECHANICAL ROOMS, ELECTRICAL ROOMS, ELEVATOR MACHINE ROOMS, AND ELEVATOR SHAFTS.

7. FIRE PROTECTION PIPING SHALL BE SIZED BY THE FIRE PROTECTION CONTRACTOR BASED ON

HYDRAULIC CALCULATIONS, REFER TO SPECIFICATIONS.

8. HEADS IN FINISHED CEILINGS SHALL BE CONCEALED TYPE WITH FLUSH-MOUNTED COVER

PLATE. COORDINATE COVER PLATE COLOR(S) WITH ARCHITECT.

9. CONTRACTOR SHALL VISIT SITE TO EXAMINE EXISTING CONDITIONS TO FULLY UNDERSTAND THE

EXTENT OF WORK TO BE PERFORMED.

10. IF NOT EXISTING, CONTRACTOR TO INSTALL SUPERVISED ISOLATION VALVES AT EACH FLOOR

TO PERMIT FLOOR-BY-FLOOR ISOLATION OF THE FIRE SPRINKLER SYSTEM DURING

CONSTRUCTION.

11. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

FIRE PROTECTION GENERAL NOTESPIPING LEGEND

DESCRIPTIONABBREVIATION

NOTE: ALL ABBREVIATIONS MAY NOT BE USED

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

FIRE PROTECTION

HEATING HOT WATER SUPPLY

HEATING HOT WATER RETURN

NITROUS OXIDE

REFRIGERANT LIQUID

REFRIGERANT PIPING

SNOW MELT RETURN

SNOW MELT SUPPLY

CHILLED WATER SUPPLY

CHILLED WATER RETURN

COMPRESSED AIR

CONDENSATE DRAIN

GLYCOL SUPPLY

GLYCOL RETURN

NON-POTABLE WATER

LIQUID PROPANE GAS

NATURAL GAS

OXYGEN

VACUUM

CHR

CHS

CA

CD

CWR

CWS

FP

GR

GS

HWR

HWS

LPG

NPW

NG

NO

O

RL

RL/ RS

SMR

SMS

VAC

FUEL OIL SUPPLY

FUEL OIL RETURN

FUEL OIL VENT

FOR

FOS

FOV

MEDIUM PRESSURE CONDENSATE

HIGH PRESSURE CONDENSATEHPC

MPC

HIGH PRESSURE STEAM

LOW PRESSURE CONDENSATELPC

HPS

LOW PRESSURE STEAM

MEDIUM PRESSURE STEAMMPS

LPS

PUMPED CONDENSATEPC

C02 CARBON DIOXIDE

ABBREVIATIONS

NOTE: ALL ABBREVIATIONS MAY NOT BE USED.

(E) EXISTING

(F) FUTURE

AD ACCESS DOOR

AIR

COND

AIR CONDITION(-ING,-ED)

APD AIR PRESSURE DROP

BD BALANCING DAMPER

BHP BRAKE HORSE POWER

BTU BRITISH THERMAL UNIT

BTUH BTU/HOUR

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

COND CONDENS(-ER, -ING, -ATION)

CV CONTROL VALVE

DB DRY BULB TEMPERATURE

DCW DOMESTIC COLD WATER

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER

RECIRC

DP DEPTH OR DEEP

EA EXHAUST AIR

EER ENERGY EFFICIENCY RATIO

EFF EFFICIENCY

ELEC ELECTRIC

ELEV ELEVATION

ENT ENTERING

EVAP EVAPORAT(-E, -ING, -ED,

-OR)

EWT ENTERING WATER

TEMPERATURE

EXT EXTERNAL

FC FLEXIBLE CONNECT(-OR,

-ION)

FD FIRE DAMPER

FLA FULL LOAD AMPS

FPI FINS PER INCH

FPM FEET PER MINUTE

FPS FEET PER SECOND

FSD FIRE SMOKE DAMPER

GE GREASE EXHAUST

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

HD HEAD

HG MERCURY

HP HORSEPOWER

HR HOUR

HT HEIGHT

HTG HEATING

HZ HERTZ (FREQUENCY)

ID INSIDE DIAMETER

IN INCH

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LG LENGTH

LH LATENT HEAT

LRA LOCKED ROTOR AMPS

LVG LEAVING

LWT LEAVING WATER

TEMPERATURE

MBH THOUSAND BTU PER HOUR

MCA MINIMUM CIRCUIT AMPS

MFR MANUFACTUR(-ER, -ED)

NC NORMALLY CLOSED

NC NOISE CRITERIA

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NPSH NET POSITIVE SUCTION

HEAD

NTS NOT TO SCALE

OA OUTSIDE AIR

OD OUTSIDE DIAMETER

OZ OUNCE

PD PRESSURE DROP OR

DIFFERENCE

PG PROPOLENE GLYCOL

PH PHASE

PPM PARTS PER MILLION

PRESS PRESSURE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSIA PSI ABSOLUTE

PSIG PSI GAUGE

R THERMAL RESISTANCE

RA RETURN AIR

RECIRC RECIRCULATE

REFR REFRIGERATION

REQD REQUIRED

RLA RATED LOAD AMPS

RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR

SC SHADING COEFFICIENT

SCFM STANDARD CUBIC FEET PER

MINUTE

SCW SOFT COLD WATER

SF SAFETY FACTOR

SH SENSIBLE HEAT

SL SEA LEVEL

SP STATIC PRESSURE

SPEC(S) SPECIFICATION(S)

SQ SQUARE

STD STANDARD

SW SOIL, WASTE

TA(R) TRANSFER AIR (RETURN)

TA(S) TRANSFER AIR (SUPPLY)

TD TEMP. DROP OR DIFF.

TEMP TEMPERATURE

THERM THERMAL

TOT TOTAL

TSTAT THERMOSTAT

V VOLT

V VENT

VAC VACUUM

VAV VARIABLE AIR VOLUME

VEL VELOCITY TEMPERATURE

VEL VELOCITY

VENT VENT, VENTILATION

VERT VERTICAL

VFD VARIABLE FREQUENCY

DRIVE

VOL VOLUME

WB WET BULB TEMP

WC WATER COLUMN

WG WATER GAUGE

WPD WATER PRESSURE DROP

WT WEIGHT

WTR WATER

SYMBOL LEGEND - MISC

DESCRIPTIONSYMBOL

VIEW OR DETAIL INDICATOR: # INDICATES DETAIL NUMBER, SHEET INDICATES

DRAWING SHEET WHERE VIEW OR DETAIL IS SHOWN.

REFERENCE LINES AND SYMBOLS

ELEVATION OR SECTION INDICATOR: # INDICATES VIEW NUMBER, SHEET

INDICATES DRAWING SHEET WHERE VIEW IS SHOWN.

NAME

### ROOM / SPACE INDICATOR

# KEYNOTE INDICATOR

# REVISION INDICATOR

XX-##

XX-##

LABEL

CFM

PLUMBING FIXTURE INDICATOR

EQUIPMENT INDICATOR

GRILLE, REGISTER, OR DIFFUSER INDICATOR

BREAKLINE

MATCHLINE INDICATOR

CONTRACT LIMIT LINE: DASHDOT, WIDE LINE

NEW CONNECTION TO EXISTING

POINT OF DEMOLITION

OR

MATCH LINE

SEE XX/XXX

1 2

A.1

B

A.8

A

STAIRS

SHAFT

FUTURE OFFICE

REFRESH

OFFICE

CORRIDOR

FIRE SPRINKLER DESIGN LEGEND

NO HATCH

LIGHT HAZARD OCCUPANCY

0.10 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM

BRICK HATCH

ORDINARY HAZARD GROUP 1 OCCUPANCY

0.15 GPM/SQFT OVER 1500 SQ. FT DRY-PIPE SYSTEM

HORIZONTAL HATCH

ORDINARY HAZARD GROUP 1 OCCUPANCY

0.15 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM

8827670

JARRETT W.

CAPSTICKS

T

A T E

OF

U T

A H

L

IC

E N S E D

PR

OFE

SSIONAL

EN

G

IN

E E R

324 S. State St., Suite 400 Salt Lake City, UT 84111

800-678-7077 801-328-5151 www.lynkengineers.com

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

L Y

N K

E N

G

IN

E E

R S

J O

B

-0

2026-09-04

/3 /2

:3

:3

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

M

M ill c re e k C it y H a ll.

rv t

FOURTH FLOOR FIRE

SUPPRESSION PLAN

FP104

OCTOBER 30, 2026

BID SET

2021535

H A

L L

S

H E

L L

S P

A C

E

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y

©2021 MHTN ARCHITECTS, INC.

SCALE: 1/4" = 1'-0"1

LEVEL 4 FIRE PROTECTION RCP

SHEET KEYNOTES

1 PROVIDE FIRE SPRINKLER SYSTEM TO ACCOMMODATE AREA(S) SHOWN.

2 COORDINATE ROUTING OF FIRE SPRINKLER SYSTEM PIPE WITH ALL TRADES. ROUTE

PIPES TO AVOID INTERFERENCE WITH CEILINGS, BUILDING STRUCTURE, AND ALL

UTILITIES AND EQUIPMENT.

3 COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ALL OTHER DEVICES

INSTALLED IN THE CEILINGS AND WITH THE LATEST REFLECTED CEILING PLANS.

WHERE INSTALLED IN 2 X 2 TILE CEILINGS, INSTALL HEADS AT CENTER POINT OF

CEILING TILES.

NORTH

0 4' 8' 16'

B

A.8

A

STAIR

SHAFT

FUTURE OFFICE

CORRIDOR

FIRE SPRINKLER DESIGN LEGEND

NO HATCH

LIGHT HAZARD OCCUPANCY

0.10 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM

BRICK HATCH

ORDINARY HAZARD GROUP 1 OCCUPANCY

0.15 GPM/SQFT OVER 1500 SQ. FT DRY-PIPE SYSTEM

HORIZONTAL HATCH

ORDINARY HAZARD GROUP 1 OCCUPANCY

0.15 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM

8827670

JARRETT W.

CAPSTICKS

T

A T E

OF

U T

A H

L

IC

E N S E D

PR

OFE

SSIONAL

EN

G

IN

E E R

324 S. State St., Suite 400 Salt Lake City, UT 84111

800-678-7077 801-328-5151 www.lynkengineers.com

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

L Y

N K

E N

G

IN

E E

R S

J O

B

-0

2026-09-04

/3 /2

:3

:3

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

M

M ill c re e k C it y H a ll.

rv t

FIFTH FLOOR FIRE

SUPPRESSION PLAN

FP105

OCTOBER 30, 2026

BID SET

2021535

H A

L L

S

H E

L L

S P

A C

E

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y

©2021 MHTN ARCHITECTS, INC.

SCALE: 1/4" = 1'-0"1

LEVEL 5 FIRE PROTECTION RCP

SHEET KEYNOTES

1 PROVIDE FIRE SPRINKLER SYSTEM TO ACCOMMODATE AREA(S) SHOWN.

2 COORDINATE ROUTING OF FIRE SPRINKLER SYSTEM PIPE WITH ALL TRADES. ROUTE

PIPES TO AVOID INTERFERENCE WITH CEILINGS, BUILDING STRUCTURE, AND ALL

UTILITIES AND EQUIPMENT.

3 COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ALL OTHER DEVICES

INSTALLED IN THE CEILINGS AND WITH THE LATEST REFLECTED CEILING PLANS.

WHERE INSTALLED IN 2 X 2 TILE CEILINGS, INSTALL HEADS AT CENTER POINT OF

CEILING TILES.

8827670

JARRETT W.

CAPSTICKS

T

A T E

OF

U T

A H

L

IC

E N S E D

PR

OFE

SSIONAL

EN

G

IN

E E R

324 S. State St., Suite 400 Salt Lake City, UT 84111

800-678-7077 801-328-5151 www.lynkengineers.com

SHEET NUMBER

E

D D

C

B

A

E

C

B

A

2 3 4 5

1 2 3 4 5

MHTN PROJECT NO.

SEAL

SHEET NAME

REVISIONS

CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT

LAST REVISION DATE.

DESCRIPTIONDATE

MHTN Architects, Inc.

280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com

NO.

ISSUE

Confidentiality Notice:

This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.

Original drawing is 30 x 42. Do not scale contents of this drawing.

L Y

N K

E N

G

IN

E E

R S

J O

B

-0

2026-09-04

/3 /2

:3

:3

P M

A u to d e s k D o c s /2

M ill c re e k C it y H a ll/

M

M ill c re e k C it y H a ll.

rv t

MECHANICAL COVER

SHEET

ME001

OCTOBER 30, 2026

BID SET

2021535

H A

L L

S

H E

L L

S P

A C

E

E

A S

T C

H A

M B

E R

S A

V E

N U

E M

IL

L C

R E

E K

U

T A

H

M

IL

L C

R E

E K

C

IT

Y

©2021 MHTN ARCHITECTS, INC.MECHANICAL SHEET INDEX

ME001 MECHANICAL COVER SHEET

ME501 MECHANICAL DETAILS

ME601 MECHANICAL SCHEDULES

MD104 FOURTH FLOOR MECHANICAL DEMOLITION PLAN

MD105 FIFTH FLOOR MECHANICAL DEMOLITION PLAN

MH104 FOURTH FLOOR MECHANICAL PLAN

MH105 FIFTH FLOOR MECHANICAL PLAN

MH114 FOURTH FLOOR MECHANICAL PIPING PLAN

MH115 FIFTH FLOOR MECHANICAL PIPING PLAN

DEFINITIONS

NOTE: ALL DEFINITIONS MAY NOT BE USED.

INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR

SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND

SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN",

"NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE

REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.

DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE

ENGINEER", AND SIMILAR PHRASES.

APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION

ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE

ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY

CONDITIONS.

FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS."

INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE

ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING,

WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS."

PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE

INTENDED USE."

INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-SUBCONTRACTOR, FOR PERFORMANCE OF A

PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY

ARE ENGAGED TO PERFORM.

SYMBOL LEGEND - DUCTWORK

DESCRIPTION

NOTE: ALL SYMBOLS MAY NOT BE USED

RECTANGULAR SUPPLY DUCT UP

RECTANGULAR SUPPLY DUCT DOWN

RECTANGULAR RETURN DUCT UP

RECTANGULAR RETURN DUCT DOWN

RECTANGULAR EXHAUST DUCT UP

RECTANGULAR EXHAUST DUCT DOWN

ROUND SUPPLY DUCT UP

ROUND SUPPLY DUCT DOWN

ROUND RETURN DUCT UP

ROUND RETURN DUCT DOWN

ROUND EXHAUST DUCT UP

ROUND EXHAUST DUCT DOWN

OVAL SUPPLY DUCT UP

OVAL SUPPLY DUCT DOWN

OVAL RETURN DUCT UP

OVAL RETURN DUCT DOWN

OVAL EXHAUST DUCT UP

OVAL EXHAUST DUCT DOWN

SPIRAL OVAL DUCT

SPIRAL ROUND DUCT

DUCT INSULATION

DUCT LINING

90° RECTANGULAR ELBOW WITH

TURNING VANES

90° ROUND RADIUS ELBOW

GORED OVAL RADIUS ELBOW

DUCT SIZE OR SHAPE TRANSITION

SYMBOL

PIPING LEGEND

DESCRIPTIONABBREVIATION

NOTE: ALL ABBREVIATIONS MAY NOT BE USED

CONDENSER WATER SUPPLY

CONDENSER WATER RETURN

FIRE PROTECTION

HEATING HOT WATER SUPPLY

HEATING HOT WATER RETURN

NITROUS OXIDE

REFRIGERANT LIQUID

REFRIGERANT PIPING

SNOW MELT RETURN

SNOW MELT SUPPLY

CHILLED WATER SUPPLY

CHILLED WATER RETURN

COMPRESSED AIR

CONDENSATE DRAIN

GLYCOL SUPPLY

GLYCOL RETURN

NON-POTABLE WATER

LIQUID PROPANE GAS

NATURAL GAS

OXYGEN

VACUUM

CHR

CHS

CA

CD

CWR

CWS

FP

GR

GS

HWR

HWS

LPG

NPW

NG

NO

O

RL

RL/ RS

SMR

SMS

VAC

FUEL OIL SUPPLY

FUEL OIL RETURN

FUEL OIL VENT

FOR

FOS

FOV

MEDIUM PRESSURE CONDENSATE

HIGH PRESSURE CONDENSATEHPC

MPC

HIGH PRESSURE STEAM

LOW PRESSURE CONDENSATELPC

HPS

LOW PRESSURE STEAM

MEDIUM PRESSURE STEAMMPS

LPS

PUMPED CONDENSATEPC

SYMBOL LEGEND - MISC

DESCRIPTIONSYMBOL

VIEW OR DETAIL INDICATOR: # INDICATES DETAIL NUMBER, SHEET INDICATES

DRAWING SHEET WHERE VIEW OR DETAIL IS SHOWN.

REFERENCE LINES AND SYMBOLS

ELEVATION OR SECTION INDICATOR: # INDICATES VIEW NUMBER, SHEET

INDICATES DRAWING SHEET WHERE VIEW IS SHOWN.

NAME

### ROOM / SPACE INDICATOR

# KEYNOTE INDICATOR

# REVISION INDICATOR

XX-##

XX-##

LABEL

CFM

PLUMBING FIXTURE INDICATOR

EQUIPMENT INDICATOR

GRILLE, REGISTER, OR DIFFUSER INDICATOR

BREAKLINE

MATCHLINE INDICATOR

CONTRACT LIMIT LINE: DASHDOT, WIDE LINE

NEW CONNECTION TO EXISTING

POINT OF DEMOLITION

OR

MATCH LINE

SEE XX/XXX

SQUARE OR RECTANGULAR

SUPPLY DIFFUSER

SYMBOL LEGEND - MECH

DESCRIPTIONSYMBOL

NOTE: ALL SYMBOLS MAY NOT BE USED

DUCT HIGH EFFICIENCY TAKE OFF WITH

BALANCING DAMPER

SQUARE OR RECTANGULAR

RETURN DIFFUSER

SQUARE OR RECTANGULAR

EXHAUST DIFFUSER

ROUND DIFFUSER

SIDEWALL GRILLE OR REGISTER

BALANCING DAMPER

FIRE DAMPER

FIRE / SMOKE COMBINATION DAMPER

LINEAR SLOT GRILLE OR DIFFUSER

FLEXIBLE DUCT

C02 CARBON DIOXIDE

T S H THERMOSTAT - SENSOR - HUMIDISTAT

1. THE MECHANICAL DRAWINGS SHOW THE GENERAL DESIGN, ARRANGEMENT, & EXTENT OF THE

MECHANICAL SYSTEM. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THESE DRAWINGS

DO NOT SHOW ALL OFFSETS, BENDS, OR ELBOWS NECESSARY FOR THE COMPLETE

INSTALLATION IN THE SPACE PROVIDED. CONTRACTOR SHALL MAKE ALTERATIONS AS MAY BE

NECESSARY TO MAKE THE SYSTEM COMPLETE & OPERATIONAL IN ACCORDANCE WITH THE

DESIGN INTENT.

2. MAJOR DEVIATIONS SUCH AS CHANGES IN SIZES, WEIGHTS, QUANTITIES, OR MATERIAL REQUIRE

PRIOR APPROVAL BY THE DESIGN ENGINEER.

3. THE DRAWINGS & SPECIFICATIONS HAVE BEEN PREPARED TO SUPPLEMENT EACH OTHER &

SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH THE ITEMS SHOWN ON ONE & NOT THE

OTHER BEING FURNISHED & INSTALLED AS THOUGH SHOWN AND CALLED OUT IN BOTH

DOCUMENTS.

4. THE ENTIRE MECHANICAL INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE

MOST RECENTLY ADOPTED BUILDING CODES, MECHANICAL CODE, PLUMBING CODE,

ELECTRICAL CODE, & ALL OTHER APPLICABLE CITY, COUNTY, STATE, & FEDERAL CODES &

REGULATIONS IN EFFECT.

5. THE ENTIRE MECHANICAL INSTALLATION SHALL CONFORM TO ALL CODES, RULES,

REGULATIONS, & REQUIREMENTS OF THE BUILDING OWNER.

6. ALL MECHANICAL COMPONENTS AND EQUIPMENT SHALL BE INSTALLED TO CONFORM WITH ANY

APPLICABLE LOCAL SEISMIC REQUIREMENTS.

7. PRIOR TO FABRICATION & INSTALLATION OF ANY MECHANICAL COMPONENT THE CONTRACTOR

SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL WORK WITH ALL OTHER BUILDING

TRADES, INCLUDING BUILDING TRADES HIRED DIRECTLY BY THE OWNER. WHERE CONFLICTS

MAY OCCUR, THEY SHALL BE RESOLVED PRIOR TO INSTALLATION.

8. VERIFY ALL REQUIRED SERVICE CONNECTIONS, INCLUDING ELECTRICAL CHARACTERISTICS, FOR

ALL EQUIPMENT PRIOR TO ORDERING OR FABRICATING MECHANICAL EQUIPMENT AND

COMPONENTS.

9. THE SPACE ABOVE CEILINGS IS LIMITED. CAREFUL COORDINATION IS REQUIRED WITH ALL

TRADES BEFORE ANY PIPE, DUCT, OR EQUIPMENT IS ORDERED &/OR INSTALLED. ANY

CONFLICTS &/OR CHANGES FOUND DURING INSTALLATION THAT RESULTS FROM THE LACK OF

COORDINATION BY THE CONTRACTORS DURING THE SHOP DRAWING PROCESS ARE THE

RESPONSIBILITY OF THE CONTRACTOR.

10. ALL MECHANICAL INFORMATION IS NOT SHOWN ON THE MECHANICAL DRAWINGS. THE

CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL INFORMATION ON ALL

OTHER CONSTRUCTION DOCUMENTS.

11. THE CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW & USE, WHERE APPROPRIATE, ALL THE

MECHANICAL DETAILS SHOWN ON THE DRAWINGS. DETAILS MAY OR MAY NOT BE CALLED OUT

ON THE DRAWINGS WITH SYMBOLS OR KEYED NOTES. ANY CHANGES RESULTING FROM FAILURE

TO INSTALL THE MECHANICAL SYSTEM WITHOUT USING THE INCLUDED DETAILS SHALL BE THE

RESPONSIBILITY OF THE CONTRACTOR.

12. ALL EQUIPMENT SHALL BE INDEPENDENTLY SUPPORTED FROM STRUCTURAL MEMBERS.

STRUCTURAL ELEMENTS SHOWN IN DETAILS MAY OR MAY NOT PERTAIN TO ANY PORTION OF

THE BUILDING. COORDINATE ALL MOUNTING REQUIREMENTS WITH ARCHITECTURAL &

STRUCTURAL DRAWINGS AND SPECIFICATIONS.

13. ALL MECHANICAL COMPONENTS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH

ALL MANUFACTURER RECOMMENDATIONS.

14. ALL SIMILAR EQUIPMENT SHALL BE OF THE SAME MANUFACTURER. AIR INLETS & OUTLETS OF

SIMILAR TYPES SHALL BE OF THE SAME MANUFACTURER.

15. ANY PART OF THE MECHANICAL INSTALLATION THAT FAILS, IS DEEMED UNFIT, OR BECOMES

DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT

NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR

EQUIPMENT CHECK-IN, SAFEKEEPING, & DAMAGE.

16. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL

CEILING DIFFUSERS & GRILLES.

17. CONTRACTOR SHALL OPERATE INSTALLED &/OR MODIFIED SYSTEMS & DEMONSTRATE ALL

ASPECTS OF THE SYSTEM TO THE ENGINEER &/OR OWNER TO PROVE ALL ASSOCIATED

SYSTEMS ARE OPERATIONAL.

18. DURING CONSTRUCTION THE CONTRACTOR SHALL MAINTAIN A SET OF AS-BUILT REDLINED

RECORD DRAWINGS AT THE PROJECT SITE. ALL CHANGES OR DEVIATIONS IN LAYOUT, ROUTING, EQUIPMENT, COMPONENTS, & ACCESSORIES SHALL BE RECORDED. THESE REDLINED

DRAWINGS SHALL BE GIVEN TO THE ARCHITECT / ENGINEER AFTER THE FINAL INSPECTION IN

ACCORDANCE WITH PROJECT SPECIFICATIONS.

19. ALL DUCT ELBOWS SHALL BE LONG RADIUS, UNLESS NOTED OTHERWISE.

MECHANICAL GENERAL NOTES

DUCT TO BE DEMOLISHED

SHUT OFF VALVE

SYMBOL LEGEND - PIPING

DESCRIPTIONSYMBOL

NOTE: ALL SYMBOLS MAY NOT BE USED

GATE VALVE

CHECK VALVE

AUTOMATIC 2-WAY VALVE

AUTOMATIC 3-WAY VALVE

GLOBE VALVE

BALL VALVE

RELIEF VALVE

PRESSURE REDUCING VALVE

BUTTERFLY VALVE

SOLENOID VALVE

ANGLE VALVE

VENTURI VALVE

BALANCING OR PLUG COCK

FLOW SETTER

EXPANSION VALVE

GAS COCK

MANUAL AIR VENT

STRAINER

GAUGE COCK

FLEXIBLE CONNECTION

PRESSURE GAUGE

THERMOMETER

PIPE REDUCER

REFRIGERANT SITE GLASS

REFRIGERANT STRAINER

90 DEGREE ELBOW UP

90 DEGREE ELBOW DOWN

90 DEGREE TEE UP

90 DEGREE TEE DOWN

PIPE UNION

PIPE CAP

PIPE ANCHOR

FLOAT AND THERMOSTATIC TRAP

REFRIGERANT FILTER DRIER

M

M

S

GAS METER

ABBREVIATIONS

NOTE: ALL ABBREVIATIONS MAY NOT BE USED.

(E) EXISTING

(F) FUTURE

AD ACCESS DOOR

AIR

COND

AIR CONDITION(-ING,-ED)

APD AIR PRESSURE DROP

BD BALANCING DAMPER

BHP BRAKE HORSE POWER

BTU BRITISH THERMAL UNIT

BTUH BTU/HOUR

CFH CUBIC FEET PER HOUR

CFM CUBIC FEET PER MINUTE

COND CONDENS(-ER, -ING, -ATION)

CV CONTROL VALVE

DB DRY BULB TEMPERATURE

DCW DOMESTIC COLD WATER

DHW DOMESTIC HOT WATER

DHWR DOMESTIC HOT WATER

RECIRC

DP DEPTH OR DEEP

EA EXHAUST AIR

EER ENERGY EFFICIENCY RATIO

EFF EFFICIENCY

ELEC ELECTRIC

ELEV ELEVATION

ENT ENTERING

EVAP EVAPORAT(-E, -ING, -ED,

-OR)

EWT ENTERING WATER

TEMPERATURE

EXT EXTERNAL

FC FLEXIBLE CONNECT(-OR,

-ION)

FD FIRE DAMPER

FLA FULL LOAD AMPS

FPI FINS PER INCH

FPM FEET PER MINUTE

FPS FEET PER SECOND

FSD FIRE SMOKE DAMPER

GE GREASE EXHAUST

GPH GALLONS PER HOUR

GPM GALLONS PER MINUTE

HD HEAD

HG MERCURY

HP HORSEPOWER

HR HOUR

HT HEIGHT

HTG HEATING

HZ HERTZ (FREQUENCY)

ID INSIDE DIAMETER

IN INCH

KW KILOWATT

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LG LENGTH

LH LATENT HEAT

LRA LOCKED ROTOR AMPS

LVG LEAVING

LWT LEAVING WATER

TEMPERATURE

MBH THOUSAND BTU PER HOUR

MCA MINIMUM CIRCUIT AMPS

MFR MANUFACTUR(-ER, -ED)

NC NORMALLY CLOSED

NC NOISE CRITERIA

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NPSH NET POSITIVE SUCTION

HEAD

NTS NOT TO SCALE

OA OUTSIDE AIR

OD OUTSIDE DIAMETER

OZ OUNCE

PD PRESSURE DROP OR

DIFFERENCE

PG PROPOLENE GLYCOL

PH PHASE

PPM PARTS PER MILLION

PRESS PRESSURE

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PSIA PSI ABSOLUTE

PSIG PSI GAUGE

R THERMAL RESISTANCE

RA RETURN AIR

RECIRC RECIRCULATE

REFR REFRIGERATION

REQD REQUIRED

RLA RATED LOAD AMPS

RPM REVOLUTIONS PER MINUTE

SA SUPPLY AIR

SC SHADING COEFFICIENT

SCFM STANDARD CUBIC FEET PER

MINUTE

SCW SOFT COLD WATER

SF SAFETY FACTOR

SH SENSIBLE HEAT

SL SEA LEVEL

SP STATIC PRESSURE

SPEC(S) SPECIFICATION(S)

SQ SQUARE

STD STANDARD

SW SOIL, WASTE

TA(R) TRANSFER AIR (RETURN)

TA(S) TRANSFER AIR (SUPPLY)

TD TEMP. DROP OR DIFF.

TEMP TEMPERATURE

THERM THERMAL

TOT TOTAL

TSTAT THERMOSTAT

V VOLT

V VENT

VAC VACUUM

VAV VARIABLE AIR VOLUME

VEL VELOCITY TEMPERATURE

VEL VELOCITY

VENT VENT, VENTILATION

VERT VERTICAL

VFD VARIABLE FREQUENCY

DRIVE

VOL VOLUME

WB WET BULB TEMP

WC WATER COLUMN

WG WATER GAUGE

WPD WATER PRESSURE DROP

WT WEIGHT

WTR WATER

CV

0-10 VOLTS

AO

VAV REHEAT BOX W/ 3-WAY VALVE DETAILVAV REHEAT BOX W/ 2-WAY VALVE DETAIL

RECTANGULAR DUCT HANGER

ROUND DUCT HANGER

1 SCALE: NTS

NOTES:

1. ALL STRAINERS ARE TO HAVE BLOWDOWN VALVE AND HOSE CONNECTION.

2. ALL COIL DRAIN VALVES ARE TO HAVE HOSE CONNECTION.

3. PROVIDE MANUAL AIR VENTS AT HIGH POINTS.

4. PROVIDE DRAINS AT LOW POINTS.

SCALE: NTS

NOTES:

1. ALL STRAINERS ARE TO HAVE BLOWDOWN VALVE AND HOSE CONNECTION.

2. ALL COIL DRAIN VALVES ARE TO HAVE HOSE CONNECTION.

3. PROVIDE MANUAL AIR VENTS AT HIGH POINTS.

4. PROVIDE DRAINS AT LOW POINTS.

NTSNTS

CV

0-10 VOLTS

AO

HHWR

HHWS

UNION (TYPICAL)

3-WAY CONTROL VALVE

STRAINER

BLOWDOWN WITH

VALVE, HOSE

CONNECTION, AND

CAP, SAME SIZE AS

BLOWDOWN.

CALIBRATED BALANCING VALVE (TYPICAL)

3/4" MANUAL DRAIN W/HOSE

CONNECTION AND CAP.

MAV

ARRANGE PIPING TO

MAINTAIN REQUIRED

SERVICE CLEARANCE

COIL

P&T TEST…