1-2026530 Millcreek City Hall L4-L5 Bid Set 10-30-26.pdf
PDF 12 MB Posted
- Attached to
- Millcreek City Hall L4-L5 Remodel
- Solicitation number
- MK-BLD26-2
- Issued by
- Salt Lake County, Moab City, Utah
About this file
Summary of Millcreek City Hall L4-L5 Remodel Bid Set
This bid set document pertains to a general contracting opportunity for the City of Millcreek, Utah, involving the interior build-out of shell space on the fourth and fifth floors of the occupied City Hall located at 1330 East Chambers Avenue. The project scope includes constructing offices, open office areas, and a conference room, with associated fire protection, mechanical, and electrical work. The contract is structured as a single prime, stipulated sum award with a Base Bid covering Level 4 complete build-out and Level 5 Offices 581 and 582, plus an Add Alternate No. 1 for the balance of Level 5. A mandatory prebid meeting and walkthrough is scheduled for Friday, November 6, 2026, at 10:00 a.m. at Millcreek City Hall, City Council Chambers, with attendance being required for bid eligibility. Sealed bids are due at the front reception desk of City Hall by 2:00 p.m. on Thursday, November 12, 2026, and will be publicly opened and read aloud immediately thereafter. Bidding documents became available on November 4, 2026, through the City website, the Utah Public Notice Website, and U3P. The successful bidder must achieve Substantial Completion within 60 calendar days after receiving the Notice to Proceed. Questions and substitution requests must be submitted by email to Kurt Hansen at khansen@millcreekut.gov with a copy to tales.brito@mhtn.com no later than Monday, November 9, 2026, at 12:00 p.m.
The contract requires a bid security deposit of 5 percent and mandates that the successful bidder furnish 100 percent performance and payment bonds. Bidders must meet minimum qualifications as specified in the bidding documents, and the award will be made to the lowest responsive and responsible bidder. Millcreek reserves the right to reject any or all bids submitted. Email and electronic bid submissions will not be accepted. ADA accommodations may be requested by contacting Kurt Hansen at khansen@millcreekut.gov or 801-214-2751.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
MHTN ARCHITECTS, INC.
280 SOUTH 400 WEST
SUITE 250
SALT LAKE CITY, UTAH 84101
PHONE: (801) 595-6700
ARCHITECTURE MECHANICAL ELECTRICAL
LYNK ENGINEERS
324 SOUTH STATE STREET
SUITE 400
SALT LAKE CITY, UT. 84111
Phone: 801.328.5151 www.lynkengineers.com
LYNK ENGINEERS
324 SOUTH STATE STREET
SUITE 400
SALT LAKE CITY, UT. 84111
Phone: 801.328.5151 www.lynkengineers.com
SHEET NUMBER
SEAL
SHEET NAME
REVISIONS:
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATENO.
Original drawing is 30 x 42. Do not scale contents of this drawing.
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
VIEW AND PRINT THIS DRAWING IN COLOR
ISSUE
MHTN PROJECT NO.
Original drawing is 30 x 42. Do not scale contents of this drawing.
D
10/30/2026
/3 /2
:4
:5
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
A
M ill c re e k C it y H a ll.
rv t
MILLCREEK CITY HALL
4TH & 5TH FLOOR REMODEL
OCTOBER 30, 2026
1330 EAST CHAMBERS AVENUE
MILLCREEK, UTAH 84106
BID SET
COVER SHEET
GS000
T
H
T
H F
L O
O R
R E
M O
D E
L
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y H
A L
L
OCTOBER 30, 2026
BID SET
2026530
©2021 MHTN ARCHITECTS, INC.
ABBREVIATIONS
AC AIR CONDITIONING
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BO BOTTOM OF
BOT BOTTOM
BRB BUCKLING RESTRAINED BRACE
BRG BEARING
CB CATCH BASIN
CFMF COLD FORMED METAL FRAMING
CFOI CONTRACTOR FURNISHED OWNER INSTALLED
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CO CLEANOUT, CLEAR OPENING
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONF CONFERENCE
CONST CONSTRUCT, CONSTRUCTION
CONT CONTINUOUS
COORD COORDINATE
CORR CORRIDOR
CTR CENTER
DB DECK BEARING ELEVATION
DEMO DEMOLITION
DF DRINKING FOUNTAIN
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DN DOWN
DR DOOR
DTL DETAIL
DWG DRAWING
EIFS EXTERIOR INSULATION AND FINISH SYSTEM
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EWC ELECTRICAL WATER COOLER
EXP EXPANSION
EXT EXTERIOR
FD FLOOR DRAIN
FEC FIRE EXTINGUISHER CABINET
FIN FINISH
FIN FLR FINISH FLOOR
FLR FLOOR
FT FOOT, FEET
GA GAUGE, GAGE
GI GALVANIZED IRON
GLULAM GLUED-LAMINATED TIMBER
GYP BD GYPSUM BOARD
HVAC HEATING, VENTILATION, AIR CONDITIONING
ID INSIDE DIAMETER
INT INTERIOR
ISO ISOMETRIC
JAN JANITOR
JT JOINT
KD KNOCK DOWN
LAB LABORATORY
LAV LAVATORY
MAINT MAINTENANCE
MAX MAXIMUM
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MH MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
OC ON CENTER
OD OUTSIDE DIAMETER
OFOI OWNER FURNISHED OWNER INSTALLED
OFCI OWNER FURNISHED CONTRACTOR INSTALLED
OH OVERHEAD
OH DR OVERHEAD DOOR
OPP OPPOSITE
PERP PERPENDICULAR
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLBG PLUMBING
PLYWD PLYWOOD
PR PAIR
PREFAB PREFABRICATED
QTY QUANTITY
RD ROOF DRAIN
RE: REFER TO
REINF REINFORCE, REINFORCING
REQD REQUIRED
REF REFRIGERATOR
RM ROOM
RO ROUGH OPENING
RTU ROOF TOP UNIT
RV ROOF VENT
SF SQUARE FEET
SIM SIMILAR
SPEC SPECIFICATION
SQ SQUARE
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
THK THICK, THICKNESS
TO TOP OF
TOB TOP OF BEAM
TOD TOP OF DECK
TOS TOP OF SLAB, TOP OF STRUCTURE
TOW TOP OF WALL
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VTR VENT THROUGH ROOF
W/ WITH
W/O WITHOUT
WC WATER CLOSET
WD WOOD
W WIDE FLANGE
WH WATER HEATER
WWF WELDED WIRE FABRIC
XFMR TRANSFORMER
N
GENERAL SYMBOLS
A1011
A101
S 3 1 A X 12 / 33
EL: 100'-0"
VERTICAL ELEVATION
SPOT ELEVATION
DRAWING
REVISION
ROOM NAME
ROOM NUMBER
KEYED NOTES
DOOR NUMBER
SHEET WHERE DRAWN
BUILDING SECTION
WALL SECTION
DETAIL
EXTERIOR ELEVATION
WINDOW TYPE
INTERIOR WALL TYPE
REVISION NUMBER INTERIOR ELEVATION
SEE PLUMBING, MECHANICAL AND ELECTRICAL FOR DISCIPLINE SYMBOLS
GRID REFERENCE MARK
A1 Starts at lower left corner Number Horizontal Letters Vertical
MHTN SHEET NUMBER
Sheet Number Sequencce Sheet Type Discipline
ACT1
ROOM VOLUME / AREA
CEILING TAG
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SHEET WHERE DRAWN
SHEET WHERE DRAWN
A 1 01
A101
SIM
CALLOUT
SHEET WHERE DRAWN
B
A
1 2
CASEWORK TYPE
DEPTH
HEIGHT
WIDTH
LEVEL
ELEVATION
A101
SIM
A101
SIM
A101
SIM
A101
SIM
QUALIFIER, IF NEEDED
FIRE RATING, IF NEEDED
CORE THICKNESS
CORE MATERIAL
THICKNESS (MIL), IF OTHER
THAN 30 MIL (20 GA)
STUD SPACING,
IF OTHER THAN 16" OC
E1
EXTERIOR WALL TYPE
ROOF TYPE
FLOOR TYPE
HEIGHT & STC
ST2 SIGNAGE TYPE
ROOM
150 SF
10'-0"
CEILING TYPE TAG
NORTH ARROW
PLAN NORTH
TRUE NORTH
CONCRETE EARTHGYPSUM
BOARD
RIGID/SEMI/
SAFING
INSULATION
MASONRY
BRICK
CONCRETE
MASONRY UNIT
HARDWOOD
EIFS
STONE
STEEL
GRAVEL BATT
INSULATION
MATERIALS
WOOD
FRAMING
PRECAST
BLOCKING
SHEET NUMBER
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
SEAL
DESCRIPTIONDATENO.
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT LAST
REVISION DATE.
CONSULTANTS
VICINITY MAP
INDEX TO DRAWINGS -
SHEET NAME
DESCRIPTIONDATENO.
ISSUED
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
VIEW AND PRINT THIS DRAWING IN COLOR
ISSUE
MHTN PROJECT NO.
Original drawing is 30 x 42. Do not scale contents of this drawing.
LYNK ENGINEERS
324 SOUTH STATE STREET
SUITE 400
SALT LAKE CITY, UT. 84111
Phone: 801.328.5151 www.lynkengineers.com
MECHANICAL
LYNK ENGINEERS
324 SOUTH STATE STREET
SUITE 400
SALT LAKE CITY, UT. 84111
Phone: 801.328.5151 www.lynkengineers.com
ELECTRICAL
10/30/2026
/3 /2
:4
:5
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
A
M ill c re e k C it y H a ll.
rv t
GS001
T
H
T
H F
L O
O R
R E
M O
D E
L
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y H
A L
L
MILLCREEK CITY HALL
4TH & 5TH FLOOR REMODEL
OCTOBER 30, 2026
1330 EAST CHAMBERS AVENUE
MILLCREEK, UTAH 84106
BID SET
BID SET
INDEX SHEET
OCTOBER 30, 2026
BID SET
2026530
©2021 MHTN ARCHITECTS, INC.
GENERAL
GS000 COVER SHEET
GS001 INDEX SHEET
GS100 LIFE SAFETY PLANS
ARCHITECTURAL
AS100 DEMOLITION PLANS
AS104 FOURTH FLOOR PLAN/RCP
AS105 FIFTH FLOOR PLAN/RCP (BASE AND ADD ALTERNATE)
FIRE PROTECTION
FP001 FIRE SUPPRESSION COVER SHEET
FP104 FOURTH FLOOR FIRE SUPPRESSION PLAN
FP105 FIFTH FLOOR FIRE SUPPRESSION PLAN
MECHANICAL
ME001 MECHANICAL COVER SHEET
ME501 MECHANICAL DETAILS
ME601 MECHANICAL SCHEDULES
MD104 FOURTH FLOOR MECHANICAL DEMOLITION PLAN
MD105 FIFTH FLOOR MECHANICAL DEMOLITION PLAN
MH104 FOURTH FLOOR MECHANICAL PLAN
MH105 FIFTH FLOOR MECHANICAL PLAN
MH114 FOURTH FLOOR MECHANICAL PIPING PLAN
MH115 FIFTH FLOOR MECHANICAL PIPING PLAN
ELECTRICAL
EE001 ELECTRICAL COVER SHEET
EE501 ELECTRICAL DETAILS
EE601 ELECTRICAL SCHEDULES
EE602 ELECTRICAL SCHEDULES
EE701 TYPICAL MOUNTING HEIGHT DETAILS
ED104 4TH & 5TH FLOOR CEILING DEMOLITION PLAN
EP104 4TH & 5TH FLOOR POWER PLAN
EP615 PANEL SCHEDULES
EL104 4TH & 5TH FLOOR LIGHTING PLAN
BASE BID
• See Specification Section 012300 “Alternates.”
• Base Bid Item 1: All Work indicated on the Drawings for the Fourth Floor.
• Base Bid Item 2: All Work indicated on the Drawings for
Fifth Floor Offices 581 and 582. Include all Work required to make Offices 581 and 582 complete and usable if Add Alternate No. 1 is not accepted, including:
• The path of travel to the existing corridor and stair
• Mechanical, electrical, fire protection and data routing through the alternate area
• Separation at the alternate boundary
ADD ALTERNATE NO. 1
• All Work indicated within the hatched Add Alternate boundary on the Fifth Floor, on sheets AS105, FP105, MD105, MH105, ED104, EP104, and EL104, including Offices 584, 585 and 586, Open Office 583, and Conference Room 580
• Includes the associated architectural, fire protection, mechanical and electrical work and the Add Alternate demolition indicated.
F E
C
FE
F E
C
TT
T
T
T
F E
C
FE
T
T
T
T
T
F E
C
FEC
RE: Original build life safety drawings for full building exiting, fire rating, and overall code compliance. Occupancy load for new office area already accounted for in the original build.
Exit Width Capacity: Exit width capacities are based on 0.3" per occupant at stairways and 0.2" per occupant at other means of egress components.
LIFE SAFETY PLAN GENERAL NOTES
9331 SF
150 GSF
BUSINESS
AREA FUNCTION (IBC TABLE 1004.1.2)
ASSEMBLY, UNCON
BUSINESS
MECH
EXIT
300 60
EXIT
170 34
220 SF
300 GSF
MECH
SHAFT
80 SF
15 GSF
ASSEMBLY, UNCON
( 86 FT )
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
110 SF
300 GSF
STORAGE
EXIT
300 60
EXIT
170 34
SHAFT
( 87 FT )
OFFICE
OFFICE
CONFERENCE ROOM
OPEN OFFICE
OFFICE
OFFICE
OFFICE
LEGEND - LIFE SAFETY
EXIT
335 67"
OCCUPANCY GROUP
OCCUPANT LOAD
OCCUPANT LOAD FACTOR
GROSS: GSF NET: NSF
SQUARE FOOTAGE
EXIT LOAD
EXIT WIDTH PROVIDED
EXIT CAPACITY
TRAVEL DISTANCE
(75 FT)
AREA USE
150 SF 7 NSF
38A-3
FIRE BARRIER - 2 HOUR
FIRE EXTINGUISHER + CABINET
SEMI-RECESSED
FIRE RESISTANT - 2 HOUR
FIRE WALL - 3 HOUR
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
09/04/2026
/3 /2
:4
:5
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
A
M ill c re e k C it y H a ll.
rv t
LIFE SAFETY
PLANS
GS100
OCTOBER 30, 2026
BID SET
2026530
T
H
T
H F
L O
O R
R E
M O
D E
L
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y H
A L
L
©2021 MHTN ARCHITECTS, INC.
SCALE:
4' - 0" 8' - 0" 16' - 0"
1/4" = 1'-0"
FOURTH FLOOR LIFE SHELL SPACE SAFETY PLAN
N
SCALE:
4' - 0" 8' - 0" 16' - 0"
1/4" = 1'-0"
FIFTH FLOOR SHELL SPACE LIFE SAFETY PLAN
N
M
F E
C
FE
SD
F E
C
CG
C G
CG
FE
SD
1 2 3
A
B
A.8
A.1
AS100A4
AS100B4
1 2 3
A
B
A.8
A.1
AS100D4
LEGEND - DEMOLITION
REMOVE & SALVAGE
DOOR & FRAME
AREA OF NO WORK
EXISTING TO REMAIN
WALLS & OTHER ITEMS
TO BE DEMOLISHED
NOTE: WHERE WALLS AND OTHER ITEMS ARE
SHOWN WITH DASHED LINES, WHETHER
KEYNOTED OR NOT, REMOVE THESE ITEMS TO
THE EXTENT INDICATED AND AS REQUIRED BY
NEW CONSTRUCTION.
Protection: Protect existing construction to remain from damage during demolition and new construction work. Repair any damage resulting from this work.
Protect in-place, existing mechanical, plumbing and electrical systems above ceilings that are not shown to be removed. This includes, but is not limited to: network cabling, coax cabling, conduits, piping, ductwork, etc.
Site Access: Coordinate phased access to the site with the Owner, including times of restricted access.
Coordination: Coordinate extent of walls to be removed with architectural floor plan(s).
Walls: Where walls are demolished, clean and repair newly exposed surfaces (gypsum and concrete) to match adjacent wall finish.
Salvage: Review with the owner, casework, furniture, equipment and wall mounted display surfaces left behind after owner move out, that are not shown on drawings. Identify as either salvage or to be disposed of by contractor.
DEMOLITION GENERAL NOTES
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
09/04/2026
/3 /2
:4
:5
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
A
M ill c re e k C it y H a ll.
rv t
DEMOLITION
PLANS
AS100
OCTOBER 30, 2026
BID SET
2026530
T
H
T
H F
L O
O R
R E
M O
D E
L
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y H
A L
L
©2021 MHTN ARCHITECTS, INC.
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1'-0"
SHELL SPACE FOURTH FLOOR DEMO
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1'-0"
SHELL SPACE FIFTH FLOOR ADD ALTERNATE DEMO 1
SCALE: 1/4" = 1'-0"
A4
LEVEL 4 NORTH DOOR
SCALE: 1/4" = 1'-0"
B4
LEVEL 4 SOUTH DOOR
SCALE: 1/4" = 1'-0"
D4
LEVEL 5 SOUTH DOOR - ADD ALTERNATE DEMO 1
M
C
F E
C
/4
2J
/4
2J
46/42N
46/42N
46/42N
/4
2J
46/42N
46/42N
C G
C G
CG
C G
C G
C G
C G
F E
C
TT
T
T
T
C
CG
1 2
A
B
A.8
A.1
16'-7" 11'-2"
1'-2"
2' -1
2'-1"
2'-1"
'-0
11'-8 3/4" 3'-0"
1' -4
/2
8'
-1
9' -6
2' -4
/8
3'-0"
16'-7" 11'-2"
AS104B4
A4
C4
D4
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
OTS
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
OFFICE
OFFICE
OFFICE
OFFICE
OPEN OFFICE
OFFICE
OFFICE
AS104
D5
AS104
D5
099123.A00
096513.A01
OPEN TO
BEYOND
096513.A01
099123.A00
AS104
D5
AS104
D5
OPEN TO
BEYOND
AS104
D5
AS104
D5
099123.A00
096513.A01
OPEN TO
BEYOND9'
-4
4'-5"
9' -4
"OPEN TO
BEYOND
099123.A00
096513.A01
CONT. JOINT SEALANT AROUND
PERIMETER OF FRAME, BOTH
SIDES (TYP)
SCHEDULED WALL
DOUBLE STUD JAMB
2"
HOLLOW METAL FRAME
DOOR PER DOOR SCHEDULE
SCHEDULED FINISH
SCHEDULED FINISH
WOOD DOOR
2"
CONT. JOINT SEALANT AT
PERIMETER OF FRAME,
BOTH SIDES (TYP)
SCHEDULED WALL
METAL STUD BOX
BEAM HEADER
HOLLOW METAL FRAME
SCHEDULED FINISH
TRANSOM GLAZING
FLOOR PLAN GENERAL NOTES
References to sheets below are provided to aid in navigating the drawings.
RE: E4/AS102 & E5/AS102 for metal stud size.
RE: Mechanical for return and supply grille type.
RE: Electrical for lighting types as well as power and data locations.
Owner Provided Equipment: Furniture layout for visualization only. Layout of owner provided equipment, tables and chairs, etc... must be done to comply with accessible clear floor space and other accessibility requirements of ICC A117.1-2017.
A minimum of 5% of the work surfaces to be accessible per IBC 1109.11.
Ceiling Grid/Panel Alignment: The design intent of the Reflected Ceiling Plans is center ceiling grids or acoustical panels between walls in both directions, or to center grids in one direction, panels in the other. If the grid does not comply with the design intent, then coordinate with Architect to adjust the ceiling layout prior to installation.
Seismic Design Category: D: Heavy-duty suspension system required / Refer to Specifications.
Seismic Bracing: Rigid bracing required at ceilings (ASTM E580)
Walls to Deck: Extend all walls to deck, including all components of the wall assembly, UNO.
Fire Sprinklers: Center sprinkler heads in acoustical panels; run in straight lines in orthogonal, rectangular spaces.
Electrical, Mechanical and other Devices: Center in acoustical panels. Coordinate feature lighting layout with Architect prior to rough-in.
Keynotes: Not all keynotes apply to this sheet.
REFLECTED CEILING PLAN GENERAL NOTES
LEGEND - FLOOR PLAN/RCP
CORNER GUARD
NOTE: PROVIDE ITEMS INDICATED IN THE LEGEND
IN THE QUANTITIES SHOWN ON THE PLAN. REFER
TO MECHANICAL & ELECTRICAL DRAWINGS FOR
LIGHT FIXTURES AND GRILLES
ACP1 - 24" X 24" ACOUSTICAL CEILING PANEL
CPT1 - 1m (MANUFACTURER: MILLIKEN, STYLE: LOW
COUNTRY - ESTUARY, COLOR: EST 124-259)
ACP2 - 24" X 48" ACOUSTICAL CEILING PANEL
(MANUFACTURER: ARKTURA, STYLE: VAPOR BLOOM)
WGP - WOOD GRILLE PANEL (OWNER PROVIDED,
CONTRACTOR INSTALLED)
2" 2'-0"
2" 3'-0"
2" 5'-6"
WOOD DOOR
HOLLOW METAL
FRAME
T01
E5
AS104
E4
AS104
2" 3'-0"
2"
E5
AS104
E4
AS104
7' -0
2"
2' -0
2"
9' -4
4" 6'
-8
2" 2'
-0
2"
T01 T01T01
CLEAR TEMPERED
FLOAT GLASS
6" 2'-0" 6"
3' -0
6"
6" 2'-0" 6"
3' -0
6"
T01T01
LINE OF FLOOR
STRUCTURE
CONTINUOUS STEEL
RUNNER SET IN BED OF
CONTINOUS ACOUSTIC
SEALANT
5/8" GYPSUM, EACH
SIDE
CONTINUOUS
ACOUSTICAL SEALANT
OVER BUTYL BACKER ROD
BATT INSULATION
3 5/8"
METAL STUD
LINE OF STRUCTURE
DEFLECTION TRACK
5/8" GYPSUM, EACH SIDE
CONTINUOUS
ACOUSTICAL SEALANT
BATT INSULATION
3 5/8"
METAL STUD
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
09/04/2026
/3 /2
:4
:5
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
A
M ill c re e k C it y H a ll.
rv t
FOURTH FLOOR
PLAN/RCP
AS104
OCTOBER 30, 2026
BID SET
2026530
T
H
T
H F
L O
O R
R E
M O
D E
L
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y H
A L
L
©2021 MHTN ARCHITECTS, INC.
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1'-0"
SHELL SPACE FOURTH FLOOR PLAN
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1'-0"
SHELL SPACE FOURTH FLOOR RCP
SCALE: 1/4" = 1'-0"
B4
L4 OPEN OFFICE WEST
SCALE: 1/4" = 1'-0"
A4
L4 OPEN OFFICE NORTH
SCALE: 1/4" = 1'-0"
C4
L4 OPEN OFFICE SOUTH
SCALE: 1/4" = 1'-0"
D4
L4 OPEN OFFICE EAST
SCALE: 3" = 1'-0"
E4
DOOR JAMB
SCALE: 3" = 1'-0"
E5
DOOR HEAD
N
N
SCALE: 1/4" = 1'-0"
D5
OFFICE FRONT
KEYNOTES
096513.A01 RESILIENT BASE
099123.A00 INTERIOR PAINTING
(MANUFACTURER: ROPPE, STYLE: PINNACLE, COLOR: 125 FIG)
(MANUFACTURER: SHERWIN-WILLIAMS, STYLE: LATEX, LOW-
VOC EGGSHELL, COLOR: WHITE OC-151)
NOTE: Finishes above apply to all offices
SCALE: 3" = 1'-0"
WALL BASE DETAIL
SCALE: 3" = 1'-0"
WALL HEAD DETAIL
F
C
CG
C G
CG
C G
C G
T
T
T
T
T
CG
F E
C
C
J J
T
T
CG
1 2
A
B
A.8
A.1
16'-7" 11'-6"
2'-0"
AS105
A3
C3
AS105C4
OFFICE
OFFICE
ADD ALTERNATE #1
9'-1" 9'-6" 9'-6"
2'-0" 2'-0" 2'-0"
'-0
2'-0" 2'-0"
1'-4"
OFFICE
OFFICE
OFFICE
CONFERENCE ROOM
OPEN OFFICE
583B3
1' -4
9' -6
B4
AS105
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
ACP1
9'-6"
OFFICE
OFFICE
OPEN OFFICE
ADD ALTERNATE #1
4' -0
10'-0"
20'-0"
'-0
ACP2
8'-6"
OFFICE
OFFICE
OFFICE
ACP1
9'-6"
CONFERENCE ROOM
ACP1
9'-6"
WGP
8'-0"
E5
AS105
099123.A00096513.A01
AS104
D5
AS104
D5
AS104
D5
OPEN TO
BEYOND
AS104
D5
AS104
D5
AS104
D5
9' -4
099123.A00
OPEN TO
BEYOND
FLOOR PLAN GENERAL NOTES
References to sheets below are provided to aid in navigating the drawings.
RE: E4/AS102 & E5/AS102 for metal stud size.
RE: Mechanical for return and supply grille type.
RE: Electrical for lighting types as well as power and data locations.
Owner Provided Equipment: Furniture layout for visualization only. Layout of owner provided equipment, tables and chairs, etc... must be done to comply with accessible clear floor space and other accessibility requirements of ICC A117.1-2017.
A minimum of 5% of the work surfaces to be accessible per IBC 1109.11.
Ceiling Grid/Panel Alignment: The design intent of the Reflected Ceiling Plans is center ceiling grids or acoustical panels between walls in both directions, or to center grids in one direction, panels in the other. If the grid does not comply with the design intent, then coordinate with Architect to adjust the ceiling layout prior to installation.
Seismic Design Category: D: Heavy-duty suspension system required / Refer to Specifications.
Seismic Bracing: Rigid bracing required at ceilings (ASTM E580)
Walls to Deck: Extend all walls to deck, including all components of the wall assembly, UNO.
Fire Sprinklers: Center sprinkler heads in acoustical panels; run in straight lines in orthogonal, rectangular spaces.
Electrical, Mechanical and other Devices: Center in acoustical panels. Coordinate feature lighting layout with Architect prior to rough-in.
Keynotes: Not all keynotes apply to this sheet.
REFLECTED CEILING PLAN GENERAL NOTES
LEGEND - FLOOR PLAN/RCP
CORNER GUARD
NOTE: PROVIDE ITEMS INDICATED IN THE LEGEND
IN THE QUANTITIES SHOWN ON THE PLAN. REFER
TO MECHANICAL & ELECTRICAL DRAWINGS FOR
LIGHT FIXTURES AND GRILLES
ACP1 - 24" X 24" ACOUSTICAL CEILING PANEL
CPT1 - 1m (MANUFACTURER: MILLIKEN, STYLE: LOW
COUNTRY - ESTUARY, COLOR: EST 124-259)
ACP2 - 24" X 48" ACOUSTICAL CEILING PANEL
(MANUFACTURER: ARKTURA, STYLE: VAPOR BLOOM)
WGP - WOOD GRILLE PANEL (OWNER PROVIDED,
CONTRACTOR INSTALLED)
SYMBOL LEGEND:
B - SEISMIC CLIP
X - PERIMETER WIRES
X - HANGER WIRES
ATTACHED WALL
U N
A T
T A
C H
D
W
A
LL
CEILING PLAN
B B B X X X
B
B
B
B
B
B
B
B
X X
X X
X X
X X
X
X
X
X
X
X
X
X X X X
PERIMETER WIRE
HANGER WIRE
LATER FORCE BRACING
REQUIRED, THIS LOCATION
ONLY
X
45.0°
.0
15°
45 45
VERTICAL
COMPRESSION STRUT
12 GA. SPLAY WIRE IN
PLANE OF EACH
COMPONENT
MAIN RUNNER
CROSS RUNNERNOTE: SPLAY WIRES WITH STRUT TO BE 12'-0" O.C.
EACH DIRECTION - THE FIRST POINT OF
BRACING TO BE WITHIN 6'-0" FROM EACH WALL
4" MAXTYP
09ADTCL001
09ADTCL009
12 GA. PERIMETER
WIRE
SEISMIC CLIP
RUNNER
7/8" WALL MOLDING
NOTE: FOR UNATTACHED WALL CONDITION
TYP
8" MAX
7/8"
3/4"
09ADTCL010
NOTE: FOR ATTACHED WALL CONDITION
12 GA. PERIMETER
WIRE
SEISMIC CLIP
RUNNER
7/8" WALL MOLDING
TYP
8" MAX
7/8"
CONCRETE AS SCHEDULED
ROPPE #24 REDUCER STRIP OR
EQ IN THE COLOR 125 FIG
CARPET FINISH AS
SCHEDULED
OPEN TO
BEYOND
OWNER PROVIDED SIGN. VERIFY
POSITION W/ ARCHITECT PRIOR TO
INSTALATION
096513.A01099123.A00
ACOUSTICAL CEILING
PANEL SYSTEM
EDGE TRIM
PROVIDE SHOP CUT-
OUT FOR GROMMETS
(2)
HEFELE 1100 LBS
SUPPORT BRACKET
LAMINATE
COUNTERTOP WITH
WOOD EDGE
2' -6
2'-6"
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
09/04/2026
/3 /2
:4
:5
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
A
M ill c re e k C it y H a ll.
rv t
FIFTH FLOOR
PLAN/RCP (BASE
AND ADD
ALTERNATE)
AS105
OCTOBER 30, 2026
BID SET
2026530
T
H
T
H F
L O
O R
R E
M O
D E
L
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y H
A L
L
©2021 MHTN ARCHITECTS, INC.
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1'-0"
SHELL SPACE FIFTH FLOOR PLAN
SCALE:
2' - 0" 4' - 0" 8' - 0"
1/4" = 1'-0"
SHELL SPACE FIFTH FLOOR RCP
SCALE: 1/4" = 1'-0"
A3
L5 OPEN OFFICE NORTH
SCALE: 1/4" = 1'-0"
C3
L5 OPEN OFFICE SOUTH
SCALE: 1/4" = 1'-0"
C4
N. CORRIDOR
N
N
KEYNOTES
096513.A01 RESILIENT BASE
099123.A00 INTERIOR PAINTING
(MANUFACTURER: ROPPE, STYLE: PINNACLE, COLOR: 125 FIG)
(MANUFACTURER: BENJAMIN MORE, STYLE: LATEX, LOW-VOC
EGGSHELL, COLOR: WHITE OC-151)
NOTE: Finishes above apply to all offices
SCALE: 1 1/2" = 1'-0"
D3
TYPICAL CEILING DETAIL
SCALE: 1 1/2" = 1'-0"
D4
DETAIL
SCALE: 1 1/2" = 1'-0"
E4
TYPICAL DETAIL
SCALE: 1 1/2" = 1'-0"
E3
TYPICAL DETAIL
SCALE: 3" = 1'-0"
D5
FLOOR - CARPET TO CONCRETE
SCALE: 1/4" = 1'-0"
B3
L5 OPEN OFFICE EAST
SCALE: 1 1/2" = 1'-0"
E5
CEILING DETAIL
SCALE: 3/4" = 1'-0"
B4
COUNTER TOP
8827670
JARRETT W.
CAPSTICKS
T
A T E
OF
U T
A H
L
IC
E N S E D
PR
OFE
SSIONAL
EN
G
IN
E E R
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 www.lynkengineers.com
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
L Y
N K
E N
G
IN
E E
R S
J O
B
-0
2026-09-04
/3 /2
:3
:3
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
M
M ill c re e k C it y H a ll.
rv t
FIRE SUPPRESSION
COVER SHEET
FP001
OCTOBER 30, 2026
BID SET
2021535
H A
L L
S
H E
L L
S P
A C
E
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y
©2021 MHTN ARCHITECTS, INC.
DEFINITIONS
NOTE: ALL DEFINITIONS MAY NOT BE USED.
INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR
SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND
SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN",
"NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE
REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.
DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE
ENGINEER", AND SIMILAR PHRASES.
APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION
ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE
ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY
CONDITIONS.
FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS."
INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE
ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING,
WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS."
PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE
INTENDED USE."
INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-SUBCONTRACTOR, FOR PERFORMANCE OF A
PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY
ARE ENGAGED TO PERFORM.
FIRE PROTECTION SHEET INDEX
FP001 FIRE SUPPRESSION COVER SHEET
FP104 FOURTH FLOOR FIRE SUPPRESSION PLAN
FP105 FIFTH FLOOR FIRE SUPPRESSION PLAN
1. MODIFY THE EXISTING BUILDING FIRE PROTECTION SYSTEM AS NECESSARY TO PROVIDE
COMPLETE COVERAGE FIRE PROTECTION SYSTEMS FOR THE AREAS OF WORK. EXCEPT
WHERE REQUIRED OTHERWISE, THE FIRE PROTECTION SYSTEMS SHALL BE COMPLETE
COVERAGE AUTOMATIC WET PIPE SPRINKLER SYSTEM, IN ACCORDANCE WITH NFPA 13.
2. COORDINATE INSTALLATION LOCATION OF SPRINKLER HEADS WITH ALL OTHER DEVICES
INSTALLED IN THE CEILINGS AND WITH THE LATEST REFLECTED CEILING PLANS.
3. CENTER SPRINKLER HEADS IN LAY-IN CEILING TILES.
4. PROVIDE SPRINKLERS BENEATH HVAC DUCT OBSTRUCTIONS OVER 48" WIDE, PER NFPA 13;
REFER TO HVAC DRAWINGS TO DETERMINE OCCURRENCE(S) OF DUCT OBSTRUCTIONS OVER
48" WIDE.
5. COORDINATE ALL SPRINKLER ALARM/SUPERVISORY TIE-IN CONNECTIONS WITH FIRE ALARM
SYSTEM CONTRACTOR. MONITOR ALL FIRE SPRINKLER SYSTEM VALVES ON THE FIRE ALARM
SYSTEM.
6. PROVIDE WIRE GUARDS OVER SPRINKLERS WITHIN MECHANICAL ROOMS, ELECTRICAL ROOMS, ELEVATOR MACHINE ROOMS, AND ELEVATOR SHAFTS.
7. FIRE PROTECTION PIPING SHALL BE SIZED BY THE FIRE PROTECTION CONTRACTOR BASED ON
HYDRAULIC CALCULATIONS, REFER TO SPECIFICATIONS.
8. HEADS IN FINISHED CEILINGS SHALL BE CONCEALED TYPE WITH FLUSH-MOUNTED COVER
PLATE. COORDINATE COVER PLATE COLOR(S) WITH ARCHITECT.
9. CONTRACTOR SHALL VISIT SITE TO EXAMINE EXISTING CONDITIONS TO FULLY UNDERSTAND THE
EXTENT OF WORK TO BE PERFORMED.
10. IF NOT EXISTING, CONTRACTOR TO INSTALL SUPERVISED ISOLATION VALVES AT EACH FLOOR
TO PERMIT FLOOR-BY-FLOOR ISOLATION OF THE FIRE SPRINKLER SYSTEM DURING
CONSTRUCTION.
11. REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
FIRE PROTECTION GENERAL NOTESPIPING LEGEND
DESCRIPTIONABBREVIATION
NOTE: ALL ABBREVIATIONS MAY NOT BE USED
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
FIRE PROTECTION
HEATING HOT WATER SUPPLY
HEATING HOT WATER RETURN
NITROUS OXIDE
REFRIGERANT LIQUID
REFRIGERANT PIPING
SNOW MELT RETURN
SNOW MELT SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
COMPRESSED AIR
CONDENSATE DRAIN
GLYCOL SUPPLY
GLYCOL RETURN
NON-POTABLE WATER
LIQUID PROPANE GAS
NATURAL GAS
OXYGEN
VACUUM
CHR
CHS
CA
CD
CWR
CWS
FP
GR
GS
HWR
HWS
LPG
NPW
NG
NO
O
RL
RL/ RS
SMR
SMS
VAC
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
FOR
FOS
FOV
MEDIUM PRESSURE CONDENSATE
HIGH PRESSURE CONDENSATEHPC
MPC
HIGH PRESSURE STEAM
LOW PRESSURE CONDENSATELPC
HPS
LOW PRESSURE STEAM
MEDIUM PRESSURE STEAMMPS
LPS
PUMPED CONDENSATEPC
C02 CARBON DIOXIDE
ABBREVIATIONS
NOTE: ALL ABBREVIATIONS MAY NOT BE USED.
(E) EXISTING
(F) FUTURE
AD ACCESS DOOR
AIR
COND
AIR CONDITION(-ING,-ED)
APD AIR PRESSURE DROP
BD BALANCING DAMPER
BHP BRAKE HORSE POWER
BTU BRITISH THERMAL UNIT
BTUH BTU/HOUR
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
COND CONDENS(-ER, -ING, -ATION)
CV CONTROL VALVE
DB DRY BULB TEMPERATURE
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER
RECIRC
DP DEPTH OR DEEP
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EFF EFFICIENCY
ELEC ELECTRIC
ELEV ELEVATION
ENT ENTERING
EVAP EVAPORAT(-E, -ING, -ED,
-OR)
EWT ENTERING WATER
TEMPERATURE
EXT EXTERNAL
FC FLEXIBLE CONNECT(-OR,
-ION)
FD FIRE DAMPER
FLA FULL LOAD AMPS
FPI FINS PER INCH
FPM FEET PER MINUTE
FPS FEET PER SECOND
FSD FIRE SMOKE DAMPER
GE GREASE EXHAUST
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HD HEAD
HG MERCURY
HP HORSEPOWER
HR HOUR
HT HEIGHT
HTG HEATING
HZ HERTZ (FREQUENCY)
ID INSIDE DIAMETER
IN INCH
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LG LENGTH
LH LATENT HEAT
LRA LOCKED ROTOR AMPS
LVG LEAVING
LWT LEAVING WATER
TEMPERATURE
MBH THOUSAND BTU PER HOUR
MCA MINIMUM CIRCUIT AMPS
MFR MANUFACTUR(-ER, -ED)
NC NORMALLY CLOSED
NC NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NPSH NET POSITIVE SUCTION
HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
OZ OUNCE
PD PRESSURE DROP OR
DIFFERENCE
PG PROPOLENE GLYCOL
PH PHASE
PPM PARTS PER MILLION
PRESS PRESSURE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA PSI ABSOLUTE
PSIG PSI GAUGE
R THERMAL RESISTANCE
RA RETURN AIR
RECIRC RECIRCULATE
REFR REFRIGERATION
REQD REQUIRED
RLA RATED LOAD AMPS
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER
MINUTE
SCW SOFT COLD WATER
SF SAFETY FACTOR
SH SENSIBLE HEAT
SL SEA LEVEL
SP STATIC PRESSURE
SPEC(S) SPECIFICATION(S)
SQ SQUARE
STD STANDARD
SW SOIL, WASTE
TA(R) TRANSFER AIR (RETURN)
TA(S) TRANSFER AIR (SUPPLY)
TD TEMP. DROP OR DIFF.
TEMP TEMPERATURE
THERM THERMAL
TOT TOTAL
TSTAT THERMOSTAT
V VOLT
V VENT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VEL VELOCITY TEMPERATURE
VEL VELOCITY
VENT VENT, VENTILATION
VERT VERTICAL
VFD VARIABLE FREQUENCY
DRIVE
VOL VOLUME
WB WET BULB TEMP
WC WATER COLUMN
WG WATER GAUGE
WPD WATER PRESSURE DROP
WT WEIGHT
WTR WATER
SYMBOL LEGEND - MISC
DESCRIPTIONSYMBOL
VIEW OR DETAIL INDICATOR: # INDICATES DETAIL NUMBER, SHEET INDICATES
DRAWING SHEET WHERE VIEW OR DETAIL IS SHOWN.
REFERENCE LINES AND SYMBOLS
ELEVATION OR SECTION INDICATOR: # INDICATES VIEW NUMBER, SHEET
INDICATES DRAWING SHEET WHERE VIEW IS SHOWN.
NAME
### ROOM / SPACE INDICATOR
# KEYNOTE INDICATOR
# REVISION INDICATOR
XX-##
XX-##
LABEL
CFM
PLUMBING FIXTURE INDICATOR
EQUIPMENT INDICATOR
GRILLE, REGISTER, OR DIFFUSER INDICATOR
BREAKLINE
MATCHLINE INDICATOR
CONTRACT LIMIT LINE: DASHDOT, WIDE LINE
NEW CONNECTION TO EXISTING
POINT OF DEMOLITION
OR
MATCH LINE
SEE XX/XXX
1 2
A.1
B
A.8
A
STAIRS
SHAFT
FUTURE OFFICE
REFRESH
OFFICE
CORRIDOR
FIRE SPRINKLER DESIGN LEGEND
NO HATCH
LIGHT HAZARD OCCUPANCY
0.10 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM
BRICK HATCH
ORDINARY HAZARD GROUP 1 OCCUPANCY
0.15 GPM/SQFT OVER 1500 SQ. FT DRY-PIPE SYSTEM
HORIZONTAL HATCH
ORDINARY HAZARD GROUP 1 OCCUPANCY
0.15 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM
8827670
JARRETT W.
CAPSTICKS
T
A T E
OF
U T
A H
L
IC
E N S E D
PR
OFE
SSIONAL
EN
G
IN
E E R
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 www.lynkengineers.com
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
L Y
N K
E N
G
IN
E E
R S
J O
B
-0
2026-09-04
/3 /2
:3
:3
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
M
M ill c re e k C it y H a ll.
rv t
FOURTH FLOOR FIRE
SUPPRESSION PLAN
FP104
OCTOBER 30, 2026
BID SET
2021535
H A
L L
S
H E
L L
S P
A C
E
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y
©2021 MHTN ARCHITECTS, INC.
SCALE: 1/4" = 1'-0"1
LEVEL 4 FIRE PROTECTION RCP
SHEET KEYNOTES
1 PROVIDE FIRE SPRINKLER SYSTEM TO ACCOMMODATE AREA(S) SHOWN.
2 COORDINATE ROUTING OF FIRE SPRINKLER SYSTEM PIPE WITH ALL TRADES. ROUTE
PIPES TO AVOID INTERFERENCE WITH CEILINGS, BUILDING STRUCTURE, AND ALL
UTILITIES AND EQUIPMENT.
3 COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ALL OTHER DEVICES
INSTALLED IN THE CEILINGS AND WITH THE LATEST REFLECTED CEILING PLANS.
WHERE INSTALLED IN 2 X 2 TILE CEILINGS, INSTALL HEADS AT CENTER POINT OF
CEILING TILES.
NORTH
0 4' 8' 16'
B
A.8
A
STAIR
SHAFT
FUTURE OFFICE
CORRIDOR
FIRE SPRINKLER DESIGN LEGEND
NO HATCH
LIGHT HAZARD OCCUPANCY
0.10 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM
BRICK HATCH
ORDINARY HAZARD GROUP 1 OCCUPANCY
0.15 GPM/SQFT OVER 1500 SQ. FT DRY-PIPE SYSTEM
HORIZONTAL HATCH
ORDINARY HAZARD GROUP 1 OCCUPANCY
0.15 GPM/SQFT OVER 1500 SQ. FT WET-PIPE SYSTEM
8827670
JARRETT W.
CAPSTICKS
T
A T E
OF
U T
A H
L
IC
E N S E D
PR
OFE
SSIONAL
EN
G
IN
E E R
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 www.lynkengineers.com
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
L Y
N K
E N
G
IN
E E
R S
J O
B
-0
2026-09-04
/3 /2
:3
:3
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
M
M ill c re e k C it y H a ll.
rv t
FIFTH FLOOR FIRE
SUPPRESSION PLAN
FP105
OCTOBER 30, 2026
BID SET
2021535
H A
L L
S
H E
L L
S P
A C
E
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y
©2021 MHTN ARCHITECTS, INC.
SCALE: 1/4" = 1'-0"1
LEVEL 5 FIRE PROTECTION RCP
SHEET KEYNOTES
1 PROVIDE FIRE SPRINKLER SYSTEM TO ACCOMMODATE AREA(S) SHOWN.
2 COORDINATE ROUTING OF FIRE SPRINKLER SYSTEM PIPE WITH ALL TRADES. ROUTE
PIPES TO AVOID INTERFERENCE WITH CEILINGS, BUILDING STRUCTURE, AND ALL
UTILITIES AND EQUIPMENT.
3 COORDINATE LOCATION OF FIRE SPRINKLER HEADS WITH ALL OTHER DEVICES
INSTALLED IN THE CEILINGS AND WITH THE LATEST REFLECTED CEILING PLANS.
WHERE INSTALLED IN 2 X 2 TILE CEILINGS, INSTALL HEADS AT CENTER POINT OF
CEILING TILES.
8827670
JARRETT W.
CAPSTICKS
T
A T E
OF
U T
A H
L
IC
E N S E D
PR
OFE
SSIONAL
EN
G
IN
E E R
324 S. State St., Suite 400 Salt Lake City, UT 84111
800-678-7077 801-328-5151 www.lynkengineers.com
SHEET NUMBER
E
D D
C
B
A
E
C
B
A
2 3 4 5
1 2 3 4 5
MHTN PROJECT NO.
SEAL
SHEET NAME
REVISIONS
CONTRACTOR TO VERIFY DRAWINGS IN FIELD USE REFLECT
LAST REVISION DATE.
DESCRIPTIONDATE
MHTN Architects, Inc.
280 South 400 West Suite 250 Salt Lake City, Utah 84101 Telephone (801) 595-6700 www.mhtn.com
NO.
ISSUE
Confidentiality Notice:
This document is intended for use on the Project identified herein by individuals and companies involved in the design, permitting, bidding and construction of the Project. MHTN Architects, Inc. grants limited rights to distribute and reproduce this document for this express purpose only. Distribution, printing or copying this document for purposes other than those indicated is strictly prohibited. If a digital copy of this document is received in error, please delete it.
Original drawing is 30 x 42. Do not scale contents of this drawing.
L Y
N K
E N
G
IN
E E
R S
J O
B
-0
2026-09-04
/3 /2
:3
:3
P M
A u to d e s k D o c s /2
M ill c re e k C it y H a ll/
M
M ill c re e k C it y H a ll.
rv t
MECHANICAL COVER
SHEET
ME001
OCTOBER 30, 2026
BID SET
2021535
H A
L L
S
H E
L L
S P
A C
E
E
A S
T C
H A
M B
E R
S A
V E
N U
E M
IL
L C
R E
E K
U
T A
H
M
IL
L C
R E
E K
C
IT
Y
©2021 MHTN ARCHITECTS, INC.MECHANICAL SHEET INDEX
ME001 MECHANICAL COVER SHEET
ME501 MECHANICAL DETAILS
ME601 MECHANICAL SCHEDULES
MD104 FOURTH FLOOR MECHANICAL DEMOLITION PLAN
MD105 FIFTH FLOOR MECHANICAL DEMOLITION PLAN
MH104 FOURTH FLOOR MECHANICAL PLAN
MH105 FIFTH FLOOR MECHANICAL PLAN
MH114 FOURTH FLOOR MECHANICAL PIPING PLAN
MH115 FIFTH FLOOR MECHANICAL PIPING PLAN
DEFINITIONS
NOTE: ALL DEFINITIONS MAY NOT BE USED.
INDICATED: THE TERM "INDICATED" REFERS TO GRAPHIC REPRESENTATIONS, NOTES, OR
SCHEDULES ON THE DRAWINGS, OTHER PARAGRAPHS OR SCHEDULES IN THE SPECIFICATIONS, AND
SIMILAR REQUIREMENTS IN THE CONTRACT DOCUMENTS. WHERE TERMS SUCH AS "SHOWN",
"NOTED", "SCHEDULED", AND "SPECIFIED" ARE USED, IT IS TO HELP THE READER LOCATE THE
REFERENCE, NO LIMITATION ON LOCATION IS INTENDED.
DIRECTED: TERMS SUCH AS "DIRECTED", "REQUESTED", AUTHORIZED", "SELECTED", "APPROVED", "REQUIRED", AND "PERMITTED" MEAN "DIRECTED BY THE ENGINEER", "REQUESTED BY THE
ENGINEER", AND SIMILAR PHRASES.
APPROVED: THE TERM "APPROVED", WHERE USED IN CONJUNCTION WITH THE ENGINEER'S ACTION
ON THE CONTRACTOR'S SUBMITTALS, APPLICATIONS, AND REQUESTS, IS LIMITED TO THE
ENGINEER'S DUTIES AND RESPONSIBILITIES AS STATED IN GENERAL AND SUPPLEMENTARY
CONDITIONS.
FURNISH: THE TERM "FURNISH" IS USED TO MEAN "SUPPLY AND DELIVER TO THE PROJECT SITE, READY FOR UNLOADING, UNPACKING, ASSEMBLY, INSTALLATION, AND SIMILAR OPERATIONS."
INSTALL: THE TERM "INSTALL" IS USED TO DESCRIBE OPERATIONS AT PROJECT SITE INCLUDING THE
ACTUAL "UNLOADING, UNPACKING, ASSEMBLY, ERECTION, PLACING, ANCHORING, APPLYING,
WORKING TO DIMENSION, FINISHING, CURING, PROTECTING, CLEANING, AND SIMILAR OPERATIONS."
PROVIDE: THE TERM "PROVIDE" MEANS "TO FURNISH AND INSTALL, COMPLETE AND READY FOR THE
INTENDED USE."
INSTALLER: AN "INSTALLER" IS THE CONTRACTOR OR AN ENTITY ENGAGED BY THE CONTRACTOR, EITHER AS AN EMPLOYEE, SUBCONTRACTOR, OR SUB-SUBCONTRACTOR, FOR PERFORMANCE OF A
PARTICULAR CONSTRUCTION ACTIVITY, INCLUDING INSTALLATION, ERECTION, APPLICATION, AND SIMILAR OPERATIONS. INSTALLERS ARE REQUIRED TO BE EXPERIENCED IN THE OPERATIONS THEY
ARE ENGAGED TO PERFORM.
SYMBOL LEGEND - DUCTWORK
DESCRIPTION
NOTE: ALL SYMBOLS MAY NOT BE USED
RECTANGULAR SUPPLY DUCT UP
RECTANGULAR SUPPLY DUCT DOWN
RECTANGULAR RETURN DUCT UP
RECTANGULAR RETURN DUCT DOWN
RECTANGULAR EXHAUST DUCT UP
RECTANGULAR EXHAUST DUCT DOWN
ROUND SUPPLY DUCT UP
ROUND SUPPLY DUCT DOWN
ROUND RETURN DUCT UP
ROUND RETURN DUCT DOWN
ROUND EXHAUST DUCT UP
ROUND EXHAUST DUCT DOWN
OVAL SUPPLY DUCT UP
OVAL SUPPLY DUCT DOWN
OVAL RETURN DUCT UP
OVAL RETURN DUCT DOWN
OVAL EXHAUST DUCT UP
OVAL EXHAUST DUCT DOWN
SPIRAL OVAL DUCT
SPIRAL ROUND DUCT
DUCT INSULATION
DUCT LINING
90° RECTANGULAR ELBOW WITH
TURNING VANES
90° ROUND RADIUS ELBOW
GORED OVAL RADIUS ELBOW
DUCT SIZE OR SHAPE TRANSITION
SYMBOL
PIPING LEGEND
DESCRIPTIONABBREVIATION
NOTE: ALL ABBREVIATIONS MAY NOT BE USED
CONDENSER WATER SUPPLY
CONDENSER WATER RETURN
FIRE PROTECTION
HEATING HOT WATER SUPPLY
HEATING HOT WATER RETURN
NITROUS OXIDE
REFRIGERANT LIQUID
REFRIGERANT PIPING
SNOW MELT RETURN
SNOW MELT SUPPLY
CHILLED WATER SUPPLY
CHILLED WATER RETURN
COMPRESSED AIR
CONDENSATE DRAIN
GLYCOL SUPPLY
GLYCOL RETURN
NON-POTABLE WATER
LIQUID PROPANE GAS
NATURAL GAS
OXYGEN
VACUUM
CHR
CHS
CA
CD
CWR
CWS
FP
GR
GS
HWR
HWS
LPG
NPW
NG
NO
O
RL
RL/ RS
SMR
SMS
VAC
FUEL OIL SUPPLY
FUEL OIL RETURN
FUEL OIL VENT
FOR
FOS
FOV
MEDIUM PRESSURE CONDENSATE
HIGH PRESSURE CONDENSATEHPC
MPC
HIGH PRESSURE STEAM
LOW PRESSURE CONDENSATELPC
HPS
LOW PRESSURE STEAM
MEDIUM PRESSURE STEAMMPS
LPS
PUMPED CONDENSATEPC
SYMBOL LEGEND - MISC
DESCRIPTIONSYMBOL
VIEW OR DETAIL INDICATOR: # INDICATES DETAIL NUMBER, SHEET INDICATES
DRAWING SHEET WHERE VIEW OR DETAIL IS SHOWN.
REFERENCE LINES AND SYMBOLS
ELEVATION OR SECTION INDICATOR: # INDICATES VIEW NUMBER, SHEET
INDICATES DRAWING SHEET WHERE VIEW IS SHOWN.
NAME
### ROOM / SPACE INDICATOR
# KEYNOTE INDICATOR
# REVISION INDICATOR
XX-##
XX-##
LABEL
CFM
PLUMBING FIXTURE INDICATOR
EQUIPMENT INDICATOR
GRILLE, REGISTER, OR DIFFUSER INDICATOR
BREAKLINE
MATCHLINE INDICATOR
CONTRACT LIMIT LINE: DASHDOT, WIDE LINE
NEW CONNECTION TO EXISTING
POINT OF DEMOLITION
OR
MATCH LINE
SEE XX/XXX
SQUARE OR RECTANGULAR
SUPPLY DIFFUSER
SYMBOL LEGEND - MECH
DESCRIPTIONSYMBOL
NOTE: ALL SYMBOLS MAY NOT BE USED
DUCT HIGH EFFICIENCY TAKE OFF WITH
BALANCING DAMPER
SQUARE OR RECTANGULAR
RETURN DIFFUSER
SQUARE OR RECTANGULAR
EXHAUST DIFFUSER
ROUND DIFFUSER
SIDEWALL GRILLE OR REGISTER
BALANCING DAMPER
FIRE DAMPER
FIRE / SMOKE COMBINATION DAMPER
LINEAR SLOT GRILLE OR DIFFUSER
FLEXIBLE DUCT
C02 CARBON DIOXIDE
T S H THERMOSTAT - SENSOR - HUMIDISTAT
1. THE MECHANICAL DRAWINGS SHOW THE GENERAL DESIGN, ARRANGEMENT, & EXTENT OF THE
MECHANICAL SYSTEM. BECAUSE OF THE SMALL SCALE OF THE DRAWINGS, THESE DRAWINGS
DO NOT SHOW ALL OFFSETS, BENDS, OR ELBOWS NECESSARY FOR THE COMPLETE
INSTALLATION IN THE SPACE PROVIDED. CONTRACTOR SHALL MAKE ALTERATIONS AS MAY BE
NECESSARY TO MAKE THE SYSTEM COMPLETE & OPERATIONAL IN ACCORDANCE WITH THE
DESIGN INTENT.
2. MAJOR DEVIATIONS SUCH AS CHANGES IN SIZES, WEIGHTS, QUANTITIES, OR MATERIAL REQUIRE
PRIOR APPROVAL BY THE DESIGN ENGINEER.
3. THE DRAWINGS & SPECIFICATIONS HAVE BEEN PREPARED TO SUPPLEMENT EACH OTHER &
SHALL BE INTERPRETED AS AN INTEGRAL UNIT WITH THE ITEMS SHOWN ON ONE & NOT THE
OTHER BEING FURNISHED & INSTALLED AS THOUGH SHOWN AND CALLED OUT IN BOTH
DOCUMENTS.
4. THE ENTIRE MECHANICAL INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF THE
MOST RECENTLY ADOPTED BUILDING CODES, MECHANICAL CODE, PLUMBING CODE,
ELECTRICAL CODE, & ALL OTHER APPLICABLE CITY, COUNTY, STATE, & FEDERAL CODES &
REGULATIONS IN EFFECT.
5. THE ENTIRE MECHANICAL INSTALLATION SHALL CONFORM TO ALL CODES, RULES,
REGULATIONS, & REQUIREMENTS OF THE BUILDING OWNER.
6. ALL MECHANICAL COMPONENTS AND EQUIPMENT SHALL BE INSTALLED TO CONFORM WITH ANY
APPLICABLE LOCAL SEISMIC REQUIREMENTS.
7. PRIOR TO FABRICATION & INSTALLATION OF ANY MECHANICAL COMPONENT THE CONTRACTOR
SHALL COORDINATE THE INSTALLATION OF ALL MECHANICAL WORK WITH ALL OTHER BUILDING
TRADES, INCLUDING BUILDING TRADES HIRED DIRECTLY BY THE OWNER. WHERE CONFLICTS
MAY OCCUR, THEY SHALL BE RESOLVED PRIOR TO INSTALLATION.
8. VERIFY ALL REQUIRED SERVICE CONNECTIONS, INCLUDING ELECTRICAL CHARACTERISTICS, FOR
ALL EQUIPMENT PRIOR TO ORDERING OR FABRICATING MECHANICAL EQUIPMENT AND
COMPONENTS.
9. THE SPACE ABOVE CEILINGS IS LIMITED. CAREFUL COORDINATION IS REQUIRED WITH ALL
TRADES BEFORE ANY PIPE, DUCT, OR EQUIPMENT IS ORDERED &/OR INSTALLED. ANY
CONFLICTS &/OR CHANGES FOUND DURING INSTALLATION THAT RESULTS FROM THE LACK OF
COORDINATION BY THE CONTRACTORS DURING THE SHOP DRAWING PROCESS ARE THE
RESPONSIBILITY OF THE CONTRACTOR.
10. ALL MECHANICAL INFORMATION IS NOT SHOWN ON THE MECHANICAL DRAWINGS. THE
CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATION OF ALL INFORMATION ON ALL
OTHER CONSTRUCTION DOCUMENTS.
11. THE CONTRACTOR SHALL BE RESPONSIBLE TO REVIEW & USE, WHERE APPROPRIATE, ALL THE
MECHANICAL DETAILS SHOWN ON THE DRAWINGS. DETAILS MAY OR MAY NOT BE CALLED OUT
ON THE DRAWINGS WITH SYMBOLS OR KEYED NOTES. ANY CHANGES RESULTING FROM FAILURE
TO INSTALL THE MECHANICAL SYSTEM WITHOUT USING THE INCLUDED DETAILS SHALL BE THE
RESPONSIBILITY OF THE CONTRACTOR.
12. ALL EQUIPMENT SHALL BE INDEPENDENTLY SUPPORTED FROM STRUCTURAL MEMBERS.
STRUCTURAL ELEMENTS SHOWN IN DETAILS MAY OR MAY NOT PERTAIN TO ANY PORTION OF
THE BUILDING. COORDINATE ALL MOUNTING REQUIREMENTS WITH ARCHITECTURAL &
STRUCTURAL DRAWINGS AND SPECIFICATIONS.
13. ALL MECHANICAL COMPONENTS AND EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH
ALL MANUFACTURER RECOMMENDATIONS.
14. ALL SIMILAR EQUIPMENT SHALL BE OF THE SAME MANUFACTURER. AIR INLETS & OUTLETS OF
SIMILAR TYPES SHALL BE OF THE SAME MANUFACTURER.
15. ANY PART OF THE MECHANICAL INSTALLATION THAT FAILS, IS DEEMED UNFIT, OR BECOMES
DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AT
NO ADDITIONAL COST TO THE OWNER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
EQUIPMENT CHECK-IN, SAFEKEEPING, & DAMAGE.
16. COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL
CEILING DIFFUSERS & GRILLES.
17. CONTRACTOR SHALL OPERATE INSTALLED &/OR MODIFIED SYSTEMS & DEMONSTRATE ALL
ASPECTS OF THE SYSTEM TO THE ENGINEER &/OR OWNER TO PROVE ALL ASSOCIATED
SYSTEMS ARE OPERATIONAL.
18. DURING CONSTRUCTION THE CONTRACTOR SHALL MAINTAIN A SET OF AS-BUILT REDLINED
RECORD DRAWINGS AT THE PROJECT SITE. ALL CHANGES OR DEVIATIONS IN LAYOUT, ROUTING, EQUIPMENT, COMPONENTS, & ACCESSORIES SHALL BE RECORDED. THESE REDLINED
DRAWINGS SHALL BE GIVEN TO THE ARCHITECT / ENGINEER AFTER THE FINAL INSPECTION IN
ACCORDANCE WITH PROJECT SPECIFICATIONS.
19. ALL DUCT ELBOWS SHALL BE LONG RADIUS, UNLESS NOTED OTHERWISE.
MECHANICAL GENERAL NOTES
DUCT TO BE DEMOLISHED
SHUT OFF VALVE
SYMBOL LEGEND - PIPING
DESCRIPTIONSYMBOL
NOTE: ALL SYMBOLS MAY NOT BE USED
GATE VALVE
CHECK VALVE
AUTOMATIC 2-WAY VALVE
AUTOMATIC 3-WAY VALVE
GLOBE VALVE
BALL VALVE
RELIEF VALVE
PRESSURE REDUCING VALVE
BUTTERFLY VALVE
SOLENOID VALVE
ANGLE VALVE
VENTURI VALVE
BALANCING OR PLUG COCK
FLOW SETTER
EXPANSION VALVE
GAS COCK
MANUAL AIR VENT
STRAINER
GAUGE COCK
FLEXIBLE CONNECTION
PRESSURE GAUGE
THERMOMETER
PIPE REDUCER
REFRIGERANT SITE GLASS
REFRIGERANT STRAINER
90 DEGREE ELBOW UP
90 DEGREE ELBOW DOWN
90 DEGREE TEE UP
90 DEGREE TEE DOWN
PIPE UNION
PIPE CAP
PIPE ANCHOR
FLOAT AND THERMOSTATIC TRAP
REFRIGERANT FILTER DRIER
M
M
S
GAS METER
ABBREVIATIONS
NOTE: ALL ABBREVIATIONS MAY NOT BE USED.
(E) EXISTING
(F) FUTURE
AD ACCESS DOOR
AIR
COND
AIR CONDITION(-ING,-ED)
APD AIR PRESSURE DROP
BD BALANCING DAMPER
BHP BRAKE HORSE POWER
BTU BRITISH THERMAL UNIT
BTUH BTU/HOUR
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
COND CONDENS(-ER, -ING, -ATION)
CV CONTROL VALVE
DB DRY BULB TEMPERATURE
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER
RECIRC
DP DEPTH OR DEEP
EA EXHAUST AIR
EER ENERGY EFFICIENCY RATIO
EFF EFFICIENCY
ELEC ELECTRIC
ELEV ELEVATION
ENT ENTERING
EVAP EVAPORAT(-E, -ING, -ED,
-OR)
EWT ENTERING WATER
TEMPERATURE
EXT EXTERNAL
FC FLEXIBLE CONNECT(-OR,
-ION)
FD FIRE DAMPER
FLA FULL LOAD AMPS
FPI FINS PER INCH
FPM FEET PER MINUTE
FPS FEET PER SECOND
FSD FIRE SMOKE DAMPER
GE GREASE EXHAUST
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HD HEAD
HG MERCURY
HP HORSEPOWER
HR HOUR
HT HEIGHT
HTG HEATING
HZ HERTZ (FREQUENCY)
ID INSIDE DIAMETER
IN INCH
KW KILOWATT
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LG LENGTH
LH LATENT HEAT
LRA LOCKED ROTOR AMPS
LVG LEAVING
LWT LEAVING WATER
TEMPERATURE
MBH THOUSAND BTU PER HOUR
MCA MINIMUM CIRCUIT AMPS
MFR MANUFACTUR(-ER, -ED)
NC NORMALLY CLOSED
NC NOISE CRITERIA
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NPSH NET POSITIVE SUCTION
HEAD
NTS NOT TO SCALE
OA OUTSIDE AIR
OD OUTSIDE DIAMETER
OZ OUNCE
PD PRESSURE DROP OR
DIFFERENCE
PG PROPOLENE GLYCOL
PH PHASE
PPM PARTS PER MILLION
PRESS PRESSURE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PSIA PSI ABSOLUTE
PSIG PSI GAUGE
R THERMAL RESISTANCE
RA RETURN AIR
RECIRC RECIRCULATE
REFR REFRIGERATION
REQD REQUIRED
RLA RATED LOAD AMPS
RPM REVOLUTIONS PER MINUTE
SA SUPPLY AIR
SC SHADING COEFFICIENT
SCFM STANDARD CUBIC FEET PER
MINUTE
SCW SOFT COLD WATER
SF SAFETY FACTOR
SH SENSIBLE HEAT
SL SEA LEVEL
SP STATIC PRESSURE
SPEC(S) SPECIFICATION(S)
SQ SQUARE
STD STANDARD
SW SOIL, WASTE
TA(R) TRANSFER AIR (RETURN)
TA(S) TRANSFER AIR (SUPPLY)
TD TEMP. DROP OR DIFF.
TEMP TEMPERATURE
THERM THERMAL
TOT TOTAL
TSTAT THERMOSTAT
V VOLT
V VENT
VAC VACUUM
VAV VARIABLE AIR VOLUME
VEL VELOCITY TEMPERATURE
VEL VELOCITY
VENT VENT, VENTILATION
VERT VERTICAL
VFD VARIABLE FREQUENCY
DRIVE
VOL VOLUME
WB WET BULB TEMP
WC WATER COLUMN
WG WATER GAUGE
WPD WATER PRESSURE DROP
WT WEIGHT
WTR WATER
CV
0-10 VOLTS
AO
VAV REHEAT BOX W/ 3-WAY VALVE DETAILVAV REHEAT BOX W/ 2-WAY VALVE DETAIL
RECTANGULAR DUCT HANGER
ROUND DUCT HANGER
1 SCALE: NTS
NOTES:
1. ALL STRAINERS ARE TO HAVE BLOWDOWN VALVE AND HOSE CONNECTION.
2. ALL COIL DRAIN VALVES ARE TO HAVE HOSE CONNECTION.
3. PROVIDE MANUAL AIR VENTS AT HIGH POINTS.
4. PROVIDE DRAINS AT LOW POINTS.
SCALE: NTS
NOTES:
1. ALL STRAINERS ARE TO HAVE BLOWDOWN VALVE AND HOSE CONNECTION.
2. ALL COIL DRAIN VALVES ARE TO HAVE HOSE CONNECTION.
3. PROVIDE MANUAL AIR VENTS AT HIGH POINTS.
4. PROVIDE DRAINS AT LOW POINTS.
NTSNTS
CV
0-10 VOLTS
AO
HHWR
HHWS
UNION (TYPICAL)
3-WAY CONTROL VALVE
STRAINER
BLOWDOWN WITH
VALVE, HOSE
CONNECTION, AND
CAP, SAME SIZE AS
BLOWDOWN.
CALIBRATED BALANCING VALVE (TYPICAL)
3/4" MANUAL DRAIN W/HOSE
CONNECTION AND CAP.
MAV
ARRANGE PIPING TO
MAINTAIN REQUIRED
SERVICE CLEARANCE
COIL
P&T TEST…
This is the start of the file's text. The full file is on GovTribe.