This is an architectural/engineering drawing (As-Built plan) for a Repair Heavy Metal Basin Facility (Facility B62528) at Tinker Air Force Base in Oklahoma. The plan details five key construction modifications: (1) installing a new 10' wide by 10' tall manually operated overhead door with chain operator, (2) installing a new water heater structural support at approximately 8 feet above floor level with an integrated drain pan, (3) creating 6" concrete housekeeping pads to support new tanks on existing concrete, (4) applying a new chemical-resistant coating to interior containment area surfaces, and (5) installing a chemical pump and air compressor structural support with a base set at the top of the containment dike, including an integrated drain pan. The drawing is dated 21 December 2009, created by the Air Force Materiel Command's 72nd ABW Civil Engineer Directorate, with design work completed by D. Cruz, drawn by Z. Henson, and checked by M. Ale.

View the file

Other files

File Type Posted
Solicitation - FA813726R0001.pdf PDF
Repair B62528 round 2 RFI CO Signed Nov 2025.pdf PDF
Site Visit Sign in Oct 21.jpeg JPEG file
Solicitation FA813726R0001.pdf PDF
RFI Response B62528 CO Signed.pdf PDF
090204G-01.pdf PDF
0311M-03.pdf PDF
0311M-04.pdf PDF
62528.pdf PDF
090204C-01.pdf PDF
62528A-FP01-Model.pdf PDF
090204E-04.pdf PDF
2020 TAFB Facility Standard.pdf PDF
2024 TAFB Electrical Standards.pdf PDF
Att13_250031- drawings - 25MAR2025.pdf PDF
Att10_250031 - SOW MACB DB.pdf PDF
Att12_250031 - Submittal Register_v4.xlsx XLSX spreadsheet
090204M-03 (002).jpg JPG image
090204E-01.pdf PDF
090204M-02.pdf PDF
090204E-02.pdf PDF
Att11_250031 - Design Narrative.pdf PDF
911035W.pdf PDF
090204E-03.pdf PDF
0311G-01.pdf PDF
860261.pdf PDF
0311M-02.pdf PDF
0311E-01.pdf PDF
090204M-01.pdf PDF
0311M-05.pdf PDF
090204C-02.pdf PDF
0311M-01.pdf PDF
090204M-03.pdf PDF
250031 Drawing.jpg JPG image
2020 TAFB Mechanical Standard.pdf PDF
2023 TAFB Fire Protection Standard.pdf PDF
Wage Determination OK20250049.pdf PDF
Show all 37

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OF

AIR FORCE MATERIEL COMMAND

72 ABW CIVIL ENGINEER DIRECTORATE

TINKER AFB, OK

T I N

K E

R

A

I R

F

O R

C E

B

A S

E

O

K L

A H

O M

A

P R

O J E

T

N

F O

R M

A T

I O

N

Q P r o j e c t D

E S

I G

N s

S u p p o r t

D r a w i n g s

D E

S I G

N

F

I L

E

L

O C

A T

I O

N

R E

V I S

I O

N S

M A

R K

D E

S I G

N

G

R O

U P

D R

A W

N

B

Y

C H

E C

K E

D

B

Y

D E

S I G

N E

D

B

Y

D A

T E

D E

S C

R I P

T I O

N

2 3 4

E

D

C

B

A

M A

N A

G E

M E

F O

R M

A T

I O

N

1 2

E

D

C

B

A

I S

S U

E

D

A T

E

SHEET

SHEET NUMBER

S H

E E

T

T

I T

L E

D M

A G

D

C

R U

Z

M

A

L E

Z

H

E N

S O

N

D

W W

Y K

A

R E

P A

R

H

A

V Y

M

T

A L

B

A S

I N

F A

C I L I T

Y

I W

P

B

C03

C I V

I L

C O

N S

T R

U C

T I O

N

N

KEYED NOTES

A INSTALL NEW MANUALLY OPERATED

OVERHEAD DOOR. DOOR SHALL BE NOMINALLY 10'

WIDE BY 10' TALL WITH CHAIN OPERATOR. INSTALL

NEW ARCHITECTURAL STRUCTURAL MEMBERS AS

NEEDED TO FRAME IN FOR THE NEW DOOR.

INSTALL METAL TRIM AND PAINT TO MATCH

EXISTING.

B INSTALL NEW WATER HEATER STRUCTURAL

SUPPORT WITH WATER HEATER BASE AT SAME

HEIGHT AS EXISTING HORIZONTAL STRUCTURAL

MEMBER (APPROX 8' A.F.F.). SUPPORT SHALL

INCLUDE INTEGRATED DRAIN PAN WITH 3/4" MALE

THREAD FOR DRAIN CONNECTION.

C INSTALL 6" CONCRETE HOUSEKEEPING

PADS TO SUPPORT NEW TANKS. INSTALL NEW

HOUSEKEEPING PADS ON TOP OF EXISTING

CONCRETE.

D INSTALL NEW CHEMICAL RESISTANT

COATING ON THE INTERIOR SURFACES OF THE

CONTAINMENT AREA.

E INSTALL CHEMICAL PUMP AND AIR

COMPRESSOR STRUCTURAL SUPPORT WITH BASE

SET AT TOP OF CONTAINMENT DIKE. SUPPORT

SHALL INCLUDE INTEGRATED DRAIN PAN WITH 3/4"

MALE THREAD FOR DRAIN CONNECTION.