SECTION 09 90 00 PAGE 1 OF 5
DIVISION 09 - FINISHES
SECTION - 09 90 00
PAINTINGS AND COATINGS
PART 1 GENERAL
1.1 SD-03 PRODUCT DATA: Submit manufacturer's technical data sheets for specified coatings and solvents.
1.2 SD-04 SAMPLES: Submit 12” x 12” samples of each paint color on the proposed substrate or 48" x 48" field mock up on an existing substrate. Cross reference color samples to color scheme and FED-STD-595 color code. Provide brand, label, product name, and product code. Provide in accordance with specified Colorway.
1.3 SD-07 CERTIFICATIONS: Provide Green Seal, GS-11 certifications for all paints and coatings.
1.4 SUPERINTENDENT QUALIFICATIONS: Engage a Painting and Coating applicator with not less than 5 years consecutive successful experience in Painting and Coating applications similar in size and type to the Painting and Coating requirements of the project.
1.5 PAINTING INCLUDED: Where a space or surface is indicated to be painted, include the following unless indicated otherwise. Surfaces behind portable objects and surface mounted articles readily detachable by removal of fasteners, such as screws and bolts.
New factory finished surfaces that require identification or color coding and factory finished surfaces that are damaged during performance of the work. Existing coated surfaces that are damaged during performance of the work.
1.6 EXTERIOR PAINTING: Includes new surfaces, existing coated surfaces, and existing uncoated surfaces, of the building and appurtenances as indicated. Also included are existing coated surfaces made bare by cleaning operations.
1.7 INTERIOR PAINTING: Includes new surfaces, existing uncoated surfaces, and existing coated surfaces of the building and appurtenances as indicated and existing coated surfaces made bare by cleaning operations. Where a space or surface is indicated to be painted, include the following items, unless indicated otherwise. Exposed columns, girders, beams, joists, and metal deck, door frames, and other contiguous surfaces.
1.8 PAINTING EXCLUDED: Do not paint the following unless indicated otherwise.
Surfaces concealed and made inaccessible by panelboards, fixed ductwork, machinery, and equipment fixed in place. Surfaces in concealed spaces. Concealed spaces are defined as enclosed spaces above suspended ceilings, furred spaces, attic spaces, crawl spaces, elevator shafts, and chases. Steel to be embedded in concrete. Copper, stainless steel, aluminum, brass, and lead except existing coated surfaces. Hardware, fittings, and other factory finished items.
SECTION 09 90 00 PAGE 2 OF 5
1.9 HERITAGE ASSESTS: Conform to: 03 01 30.10, 04 01 20.10, 04 11 00.10, 05 10 17.10, and 09 90 00.01.
PART 2 PRODUCTS
2.1 GENERAL: Provide all paintings and coatings from a single manufacturer, Sherwin-
Williams Company, PPG Architectural Finishes, Inc or Benjamin Moore & Co.
PART 3 EXECUTION
3.1 PROTECTION OF AREAS AND SPACES NOT TO BE PAINTED: Prior to surface preparation and coating applications, remove, mask, or otherwise protect, hardware, hardware accessories, machined surfaces, radiator covers, plates, lighting fixtures, public and private property, and other such items not to be coated that are in contact with surfaces to be coated. Following completion of painting, workmen skilled in the trades involved must reinstall removed items. Restore surfaces contaminated by coating materials, to original condition, and repair damaged items.
3.2 SURFACE CONDITION: Remove dirt, splinters, loose particles, grease, oil, disintegrated coatings, rust, and other foreign matter and substances deleterious to coating performance as specified for each substrate before application of paint or surface treatments in accordance with the manufacturer's specifications. Oil and grease must be removed prior to mechanical cleaning. Cleaning must be programmed so that dust and other contaminants will not fall on wet, newly painted surfaces.
3.3 EXISTING COATED SURFACES WITH MINOR DEFECTS: Sand, spackle, and treat minor defects to render them to match adjacent surfaces finish. Minor defects are defined as scratches, nicks, cracks, gouges, spalls, alligatoring, chalking, and irregularities due to partial peeling of previous coatings. Remove chalking by sanding so that when tested in accordance with ASTM D4214, the chalk rating is not less than 8.
3.4 SUBSTRATE REPAIR: Repair substrate surfaces damaged during coating removal to match adjacent surfaces and finish.
3.5 PREPARING EXISTING AND NEW NON-FERROUS METALLIC SURFACES:
Prepare surface to Steel Structures Painting Code (SSPC) SP-6, except prepare galvanized steel to SSPC SP-16. Unless otherwise noted in 05 10 17.01
3.6 PREPARING CONCRETE AND MASONRY SURFACES: Remove the following deleterious substances: Dirt, Chalking, Grease, Oil, Fungus, Mold, Loose Particles, failing paint, and Efflorescence using the gentlest means practicable. Repair or fill mortar joints and minor defects, including but not limited to spalls, in accordance with manufacturer's recommendations and prior to coating application. Allow surfaces to cure a minimum of 30 days before painting.
SECTION 09 90 00 PAGE 3 OF 5
3.7 PREPARING GYPSUM BOARD, PLASTER, AND STUCCO: Plaster and stucco must be clean and free from loose matter; gypsum board must be dry. Remove loose dirt and dust by brushing with a soft brush, rubbing with a dry cloth or vacuum-cleaning prior to application of the first coat material. Allow new plaster to age a minimum of 30 days before preparation for painting.
3.8 PREPARING WOOD SUBSTRATES: Scrape and clean knots. Before applying primer, apply coat of knot sealer recommended in writing by topcoat manufacturer for exterior use in paint system indicated. Sand surfaces that will be exposed to view, and dust off.
Prime edges, ends, faces, undersides, and backsides of wood. After priming, fill holes and imperfections in the finish surfaces with putty or plastic wood filler. Sand smooth when dried.
3.9 COATING APPLICATION: At the time of application, paint must show no signs of deterioration. Uniform suspension of pigments must be maintained during application.
Unless otherwise specified or recommended by the paint manufacturer, paint may be applied by brush, roller, or spray. Thoroughly work coating materials into joints, crevices, and open spaces. Special attention must be given to insure that all edges, corners, crevices, welds, and rivets receive a film thickness equal to that of adjacent painted surfaces. Each coat of paint must be applied so dry film must be of uniform thickness and free from runs, drops, ridges, waves, pinholes or other voids, laps, brush marks, and variations in color, texture, and finish. Hiding must be complete. Touch up damaged coatings before applying subsequent coats. Interior areas must be broom clean and dust free before and during the application of coating material. Coat surfaces with the following one coat of primer, one coat of undercoat or intermediate coat, and one topcoat to match adjacent surfaces. Topcoat coating must match adjacent surfaces where newly painting surfaces abut existing previously painted surfaces.
3.10 DRYING TIME: Allow time between coats, as recommended by the coating manufacturer, to permit thorough drying, but not to present topcoat adhesion problems.
Provide each coat in specified condition to receive next coat.
3.11 PRIMERS AND INTERMEDIATE COATS: Do not allow primers or intermediate coats to dry more than 30 days, or longer than recommended by manufacturer, before applying subsequent coats. Follow manufacturer's recommendations for surface preparation if primers or intermediate coats are allowed to dry longer than recommended by manufacturers of subsequent coatings. Each coat must cover surface of preceding coat or surface completely and there must be a visually perceptible difference in shades of successive coats.
3.12 SHEEN: Provide semi-gloss sheen for trim, doors, exterior elements and accent walls.
Provide flat sheen for ceilings. Provide eggshell sheen in all other locations unless otherwise noted.
a. EXTERIOR NONTRAFFIC SURFACES CONCRETE, CLAY MASONRY, CEMENTITIOUS STUCCO SUBSTRATES: Provide 3 part Latex System. Prime
SECTION 09 90 00 PAGE 4 OF 5
Coat must be: Primer sealer, latex. Sherwin Willams Loxon Concrete & Masonry
Primer Sealer, A24W8300, at 8.0 mils wet, 3.2 mils dry. Intermediate Coat must be: Latex, exterior, matching topcoat. Sherwin Willams A-100 Exterior Latex
Flat, A6 Series, at 4.0 mils wet, 1.2 mils dry, per coat. Topcoat must be: Latex, exterior, semi-gloss Sherwin Willams Solo Acrylic Semi-Gloss, A76 Series, at 4.0 mils wet, 1.5 mils dry, per coat.
b. EXTERIOR CMU SUBSTRATES: Provide 3 part Latex System. Block Filler must be: Block filler, latex, interior/exterior Sherwin Willams PrepRite Block
Filler, B25W25, at 75 to 125 sq. ft. per gal. Intermediate Coat must match topcoat. Topcoat must be: Sherwin Willams Solo Acrylic Semi-Gloss, A76
Series, at 4.0 mils wet, 1.5 mils dry, per coat.
c. EXTERIOR FERROUS METAL, GALVANIZED-METAL, AND ALUMINUM
SUBSTRATES: Provide manufactures PSX 700 standard two coat system over zinc primer, PSX 700 shall be applied to 5.0 mils dry film thickness (DFT).
d. EXTERIOR GYPSUM BOARD SUBSTRATES: Provide a 3 part Latex System.
Prime coat must be: Sherwin Willams PrepRite ProBlock Latex Primer/Sealer, B57-620 Series, at 4.0 mils wet, 1.4 mils dry. Intermediate Coat must match topcoat. Topcoat must be: Sherwin Willams A-100 Exterior Latex Gloss, A8
Series, at 4.0 mils wet, 1.3 mils dry, per coat.
e. EXTERIOR WOOD SUBSTRATES: Provide a 3 part Latex System. Prime coat must be: Sherwin Willams Exterior Latex Primer, B42, at 4.0 mils wet, 1.4 mils dry, per coat. Intermediate Coat must match topcoat. Topcoat must be: Sherwin
Willams A-100 Exterior Satin, A82 Series, at 4.0 mils wet, 1.2 mils dry, per coat.
f. INTERIOR WOOD SUBSTRATES: Provide a 5 part System. Prime coat shall be: Sherwin Willams Premium Wood and Wall Primer: 4.0 mils wet - 1.8 mils dry. Intermediate Coat shall match topcoat. Topcoat must be: Sherwin Willams
Pro Industrial Water Based Alkyd Urethane Enamel Finish: 5.0 mils wet – 1.7 mils dry per coat, and two coats polyurethane matte or stain as selected.
i. Provide for all cabinets.
g. INTERIOR CMU SUBSTRATES: Provide a 3 part Latex System. Prime coat must be Block Filler: Sherwin Willams PrepRite Block Filler, B25W25, at 75-125
sq. ft. per gal. Intermediate Coat must match topcoat. Topcoat must be: Sherwin
Willams ProMar 200 Zero VOC Latex Egg Shell, B20-2600 Series, at 4.0 mils wet, 1.7 mils dry, per coat.
h. INTERIOR GYPSUM SUBSTRATES: Provide a 3 part Latex System. Prime coat must be: Sherwin Willams ProMar 200 Zero VOC Latex Primer, B28W2600, at 4.0 mils wet, 1.0 mils dry. Intermediate Coat must match topcoat. Topcoat
SECTION 09 90 00 PAGE 5 OF 5
must be: Sherwin Willams ProMar 200 Zero VOC, B20-2600 Series, at 4.0 mils wet, 1.7 mils dry, per coat.
i. INTERIOR EPOXY SYSTEMS: Provide a 3 part System. Provide a 3 part
System. Prime coat shall be: Sherwin Willams Premium Wood and Wall Primer:
4.0 mils wet - 1.8 mils dry. Intermediate Coat shall match topcoat. Topcoat must be: Sherwin Willams Pro Industrial Pre-Catalyzed Waterbased Epoxy: 4.0 mils wet – 1.5 mils dry.
i. Provide Sherwin Willams Heavy Duty Block filler for new masonry walls:
34 mils wet – 18 mils dry.
ii. Provide Epoxy paint for all bathrooms, latrines, laundry rooms and behind all refrigerators.
j. DRYFALL PAINTING: Coat exposed structural steel, galvanized metal, aluminum interior ceilings and building systems, except as noted, that are not subject to wear with dryfall coatings. Select coating that will dry before droplets adversely impact existing conditions. At the end of the undertaking the facility shall be clean of all droplets.
i. Prime Coat: Primer, rust-inhibitive, water based Sherwin Willams Pro
Industrial Pro-Cryl Universal Primer, B66-310 Series, at 7.0 mils wet, 3.0 mils dry. Intermediate Coat: Dry-fall latex, flat: Sherwin Willams Pro
Industrial Waterborne Acrylic Dryfall Flat, B42-181 Series, at 6.0 mils wet, 1.5 mils dry. Top Coat: Dry-fall latex, flat: Sherwin Willams Pro
Industrial Waterborne Acrylic Dryfall Flat, B42-181 Series, at 6.0 mils wet, 1.5 mils dry.