09 51 00 - ACOUSTICAL CEILINGS Specs.pdf

PDF 186 KB Posted

Attached to
DPW Minor Construction Program MATOC Federal contract opportunity
Solicitation number
W91247-22-R-0064
Issued by
Department of the Army Materiel Command Mission and Installation Contracting Command

View the file

Other files for this federal contract opportunity

Other files attached to DPW Minor Construction Program MATOC, newest first.
File Type Posted
W91247-22-R-0064 Amendment 0002 4 Aug.pdf PDF
W91247-16-R-0064 Final RV5 18 July.pdf.pdf PDF
W91247-22-R-0064 Amendment 00001.pdf PDF
QAs W9124722R0064 Solicitation 19 July 22.pdf PDF
Attachment 1 FA-00040-22 Seed Project Final SOW 20 July.pdf PDF
W91247-16-R-0064 Final RV3 7 July.pdf PDF
08 71 00 - DOOR HARDWARE Specs.pdf PDF
26 20 00.pdf_safe Specs.pdf PDF
23 23 00.pdf_safe Specs.pdf PDF
26 05 19.pdf_safe Specs.pdf PDF
Attachment 4 - MAIDIQ Cap Rates.xlsx XLSX spreadsheet
23 00 00 AIR SUPPLY DISTRIBUTION VENTILATION AND EXHAUST SYSTEMS Specs.pdf PDF
09 26 00 - GYPSUM AND CEMENTITIOUS BOARD ASSEMBLIES Specs.pdf PDF
08 14 00 - WOOD DOORS Specs.pdf PDF
09 65 00 - RESILIENT FLOORING specs.pdf PDF
32 31 13.pdf_safe Specs.pdf PDF
32 31 13.53.pdf_safe Specs.pdf PDF
02 85 00 - MOLD REMEDIATION Specs.pdf PDF
W91247-22-R-0064 Matoc Sol final RV2 7july.pdf PDF
09 30 10 CERAMIC PORCELAIN QUARRY AND MOSAIC TILING Specs.pdf PDF
26 05 00 - COMMON WORK RESULTS FOR ELECTRICAL Specs.pdf PDF
09 90 00 - PAINTINGS AND COATINGS Specs.pdf PDF
26 05 26.doc_safe Specs.pdf PDF
01 00 00 - STANDARD ABBREVIATIONS Specs.pdf PDF
09 22 00.pdf_safe Specs.pdf PDF
Attachment 3 - Seed Project Price Schedule final.xlsx XLSX spreadsheet
attachment 1 - FA-00040-22 Seed Project SOW final.pdf PDF
22 00 00 PLUMBING GENERAL PURPOSE Specs.pdf PDF
01 Size_Standards_Table (Effective Aug 19 2019) 236220 pg.5.pdf PDF
07 60 00 - FLASHING AND SHEET METAL Specs.pdf PDF
Attachment 2 - 09 06 00 - SCHEDULES FOR FINISHES Specs.pdf PDF
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Updated: 10 July 2020

SECTION 09 51 00 PAGE 1 OF 3

DIVISION 09 - FINISHES

SECTION - 09 51 00

ACOUSTICAL CEILINGS

PART 1 GENERAL

1.1 SD-03 PRODUCT DATA: Provide product data for Acoustical ceiling tiles and grid.

1.2 SD-04 SAMPLES: Submit two samples of each type of acoustical unit and each type of suspension grid tee section showing texture, finish, and color. Provide in accordance with specified Colorway.

1.3 SD-07 CERTIFICATES: Submit third party verified ULE Greenguard Gold or equal product certificate.

1.4 SUPERINTENDENT QUALIFICATIONS: Engage an acoustical ceiling installer with not less than 5 consecutive years of successful experience in acoustical ceiling similar in size and type to the acoustical ceiling requirements of the project.

1.5 DELIVERY, STORAGE, AND HANDLING: Deliver materials to the site in the manufacturer's original unopened containers with brand name and type clearly marked.

Carefully handle and store materials in dry, watertight enclosures. Immediately before installation, store acoustical units for not less than 24 hours at the same temperature and relative humidity as the space where they will be installed in order to assure proper temperature and moisture acclimation.

1.6 ENVIRONMENTAL REQUIREMENTS: Maintain a uniform temperature of not less than 60 degrees F nor more than 85 degrees F and a relative humidity of not more than 70 percent for 24 hours before, during, and 24 hours after installation of acoustical units.

PART 2 PRODUCTS

2.1 GENERAL: Provide all acoustical ceilings assemblies, complete and useable, from a single manufacturer, Armstrong World Industries, Inc., CertainTeed Corp or USG

Interiors, Inc.

2.2 ACOUSTICAL UNITS: Provide acoustical units in accordance with ASTM E1264 Class

A. The units shall be nominal size 24 inches by 24 inches, 3/4 inches thickness for open work spaces and 5/8 inches thickness for offices. The flame spread index must be 25 or less and smoke developed index must be 50 or less in accordance with ASTM E84. Units must have a noise reduction coefficient (NRC) of 0.75 in open office areas; 0.60 in conference rooms, executive offices, teleconferencing rooms, and other rooms as designated; 0.50 in all other rooms and areas when tested on mounting Type E-400 of

ASTM E795. The Light Reflectance Coefficient must be 0.75 or greater. The minimum

Attenuation Class must be CAC 40 or greater.

SECTION 09 51 00 PAGE 2 OF 3

a. Repairs to existing acoustical ceilings: Provide square lay-in with non-directional pattern. Armstrong Fine Fissured OAE.

b. New acoustical ceilings: Provide beveled tegular with non-directional pattern.

Armstrong Ultima OAE.

2.3 EXPOSED-GRID SYSTEM: Provide exposed-grid suspension system conforming to

ASTM C635. Provide surfaces exposed to view of steel with a factory-applied FS-37886 baked-enamel finish. Provide wall molding having a flange of not less than 15/16 inch.

Provide overlapped interior corners and mitered outside corners. Suspended ceiling framing system must have the capability to support the finished ceiling, light fixtures, air diffusers, and accessories, as shown. Provide a suspension system with a maximum deflection of 1/360 of the span length. Conform seismic details to the guidance in UFC 3-

310-04 and ASTM E580/E580M

2.4 HANGING WIRES: Provide wire in accordance with ASTM A641/A641M, Class 1, and

12 gauge 0.08 inch in diameter minimum.

2.5 EYEBOLTS: Provide eyebolts of weldless, forged-carbon-steel, with a straight-shank in accordance with ASTM A489. Eyebolt size must be a minimum 1/4 inch.

PART 3 EXECUTION

3.1 INSTALLATION: Complete and dry interior finish work before installation. Complete and approve mechanical, electrical, and other work above the ceiling line prior to the start of acoustical ceiling installation. Provide acoustical work complete with necessary fastenings, clips, and other accessories required for a complete installation. Do not expose mechanical fastenings in the finished work. Lay out hangers for each individual room or space. Provide hangers to support framing around beams, ducts, columns, grilles, and other penetrations through ceilings. Keep main runners and carrying channels clear of abutting walls and partitions. Provide at least two main runners for each ceiling span.

Wherever required to bypass an object with the hanger wires, install a sub-suspension system so that all hanger wires will be plumb. Where hangers must be splayed (sloped or slanted) around obstructions, equalize the resulting force.

3.2 SUSPENSION SYSTEM: Install suspension system in accordance with ASTM

C636/C636M and as specified herein. Do not suspend hanger wires or other loads from underside of steel decking

3.3 PLUMB HANGERS: Install hangers plumb and not pressing against insulation covering ducts and pipes. Where lighting fixtures are supported from the suspended ceiling system, provide hangers at a minimum of four hangers per fixture and located not more than 6 inches from each corner of each fixture.

SECTION 09 51 00 PAGE 3 OF 3

3.4 SEISMIC RESTRAINTS: Provide manufacturer recommended seismic accessories.

3.5 ACOUSTICAL UNITS: Install acoustical units in accordance with manufacturer installation instructions. Ensure that edges of acoustical units are in close contact with metal supports, with each other, and in true alignment. Arrange acoustical units so that units less than one-half width are minimized. Hold units in exposed-grid system in place with manufacturer's standard hold-down clips, if units weigh less 1 PSF, or if required for fire resistance rating.

3.6 CLEANING: Following installation, clean dirty or discolored surfaces of acoustical units and leave them free from defects. Remove units that are damaged or improperly installed and provide new units.

File details come from the government source that posted it. Updated .