05_13_2026_EXHIBIT 2_Douglas County Detention.pdf

PDF 186 KB Posted

Attached to
Fire Suppression-DOT Storage & Sherriff Department IT and Electrical Rooms
Solicitation number
PE-64800-NONST-2026-000000077
Issued by
Douglas County, Georgia

About this file

This is an as-built architectural floor and ceiling plan exhibit prepared by CSC Design for the Douglas County Sheriff's Office Law Enforcement & Adult Detention Center located at 8470 Earl D. Lee Boulevard, Douglasville, Georgia 30134. The document, dated May 13, 2026, presents existing conditions for Room S150 (Computer Room) and Room S151 (Telecom Room), along with associated electrical and mechanical spaces including the Main Electrical Room (S123) and Emergency Electrical Room (S124). The plan documents existing equipment layouts including servers, UPS systems, server racks, electrical panels, transformers, distribution equipment, HVAC units, fire alarm systems, sprinkler heads, ceiling-mounted detectors, and various wall and ceiling-mounted fixtures. Dimensions are provided for structural elements, floor chases, and clearances throughout the documented areas, with ceiling heights ranging from 9 feet 11 inches to 19 feet 6 inches depending on finish type.

The plan includes legends identifying existing fixtures such as acoustical ceilings, gypsum ceilings, exposed ceilings, light fixtures, return air terminals, supply air terminals, and fire extinguishers. The document contains a critical note stating that all measurements are based on casual visual observations and must be field-verified prior to any fabrication or installation, and that equipment names are assumptions that may not reflect proper nomenclature. The drawings are protected under United States copyright laws and cannot be reproduced or used without written consent from CSC Design. The document serves as a baseline reference for the existing infrastructure within the detention center's utility and technology spaces.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S151

TELECOM ROOM

S150

COMPUTER ROOM

FE

EXST.

MINISPLIT

FE

EXST.

AHU

EXST.

AHU

EXST.

AHU

E X

S T

. S E

R V

E R

E X

S T

. S E

R V

E R

E X

S T

. U P

S

E X

S T

. S E

R V

E R

E X

S T

. S

R A

C K

E X

S T

. S E

R V

E R

EXST. ELECTRICAL PANELS

EXST.

ELECTRICAL

PANEL

EXST. PANELS

EXST.

LENEL

PANELS

EXST. TRP

EQUIP.

40'-5"12'-0"

4" HOUSEKEEPING PAD 4" HOUSEKEEPING PAD

EXST. FIRE

ALARM PULL

0'

-2

EXST. FLOOR

CHASES

4' -0

W

X

'-0

H

4' -0

W

X

'-0

H

S124

EMERGENCY ELECTRICAL

S123

MAIN ELECTRICAL ROOM

7'

-0

22'-4" 30'-1"

'-4

9'-0" 2'-0" 28'-1" 1'-4"

'-4

8'

-0

'-0

'-0

8" +/-

EXST. DISTRIBUTION

EQUIP. ON CONC. PAD

EXST. DISTRIBUTION

EQUIP. ON CONC. PAD

EXST. DISTRIBUTION

EQUIP. ON CONC. PAD

EXST.

ELECTRICAL

PANELS

T

EXST.

TRANSFORMER

ON CONC. PAD

EXST.

CONTROL

EQUIP.

EXST.

EQUIP.

EXST.

FLOOR

CHASES

EXST.

WALL MOUNTED

EQUIP.TT

EXST.

TRANSFORMERS

ON CONC. PAD

EXST. ELECTRICAL

PANEL

EXST. ELECTRICAL

PANELS

E X

S T

S

E R

V E

R

A

C

KEXST.

WALL MOUNTED

EQUIP.

T

EXST.

TRANSFORMER

ON CONC. PAD

EXST.

ELECTRICAL PANEL

EXST.

DISCONNECT

EXST.

ELECTRICAL PANELS

FE

EXST.

POWER DISCONNECTS

T

EXST.

TRANSFORMER

ON CONC. PAD

EXST.

ELECTRICAL PANELS

EXST.

ELECTRICAL

PANELS

EXST.

DISCONNECT

EXST.

TRANSFER

SWITCH

EXST.

CONTROLS

EQUIP.

E X

S T

. T R

A N

S F

S

W

IT

C H

E S

O N

C O

N C

P

A D

E X

S T

. D

IS

T R

IB

U

T

IO

N

Q

U

IP

. O N

C O

N C

. P A

D

SOFFIT ABOVE

12'-6" A.F.F.

SOFFIT ABOVE

12'-6" A.F.F.

4'-0" W X 7'-0" H 4'-0" W X 7'-0" H

4'-0" W X 7'-0" H

EXST. CEILING AHU SERVICE RISERS EXST. CEILING AHU SERVICE RISERS EXST. CEILING AHU SERVICE RISERS

EXST. CEILING CABLE CHASES

10' - 0"ACT-03

9' - 11"ACT-03

12' - 6"GYP

19' - 6"EXPSD. 19' - 6"EXPSD.

EXST. OVERHEAD

HVAC EQUIP.

EXST. OVERHEAD

HVAC EQUIP./VENT

RCP TAG

PTD

-EXPSD

CEILING HEIGHT

CEILING FINISH

CEILING TYPE

CEILING PATTERN

CEILING TYPE LEGEND

ACT-03 24" X 48" EXISTING ACOUSTICAL CEILING

LIGHTING FIXTURES LEGEND

2X4 EXISTING LIGHT FIXTURE

EXISTING SPRINKLER HEAD

EXISTING CEILING MOUNTED DETECTOR/SENSOR

EXISTING RETURN AIR TERMINAL

EXISTING SUPPLY AIR TERMINAL

FE EXISTING FIRE EXTINGUISHER

GYP EXISTING GYP CEILING

EXISTING CEILING MOUNTED FIRE ALARM/DETECTION

EXISTING HIGH-BAY LIGHT FIXTURE

EXPSD. EXISTING EXPOSED CEILING

Phone: (770) 345-2579

135 P RICKMAN INDUSTRIAL DR.

SUITE 100 CANTON, GA 30115

© 2026, CSC Design. These drawings are protected by the copyright laws of the United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of CSC Design.

CSC

DESIGN,

INC.

ARCHITECTS ENGINEERS&

PROJECT NUMBER:

R E

V

IS

IO

N

S

/1

/2

:4 :5

A

M Y

P ro je c ts

\2 -0

D o u g la s C o u n ty

D e te n ti o n

C e n te r A s -B u ilt

\A rc h \0

R

E V

IT

\2

-0

D o u g la s C o u n ty

D e te n ti o n C e n te r A s -B u ilt

.r v t

A-100

AS-BUILT

EXISTING FLOOR

& CEILING PLANS

C S

C .2

4.

2.

26-005

D O

U G

LA

S

C O

U N

T Y

S H

E R

IF

F

'S O

F F

IC

E

LA

W

E N

F O

R C

E M

E N

T

A D

U L T

D E

T E

N T

IO

N

C E

N T

E R

E A

R L

D . L

E E

B

LV

D D

O U

G L

A S

V

IL

L E

, G A

A-100 | 1/4" = 1'-0"1

EXISTING FLOOR PLAN

THESE PLANS AND DIMENSIONS ARE BASED ON CASUAL VISUAL

OBSERVATIONS AND MEASUREMENTS. ALL MEASUREMENTS ARE

TO BE FIELD VERIFIED PRIOR TO ANY FABRICATION OR

INSTALLATION. EQUIPMENT NAMES ARE ASSUMPTIONS AND MAY

NOT REFLECT PROPER NOMENCLATURE.

N O

D

A T

E

IS

S

U E

A-100 | 1/4" = 1'-0"2

EXISTING REFLECTED CEILING

KevinWhipple Text Box

EXHIBIT 2

Sheets
A-100 - EXISTING FLOOR & CEILING PLANS

File details come from the government source that posted it. Updated .