05_13_2026_EXHIBIT 2_Douglas County Detention.pdf
PDF 186 KB Posted
- Solicitation number
- PE-64800-NONST-2026-000000077
- Issued by
- Douglas County, Georgia
About this file
This is an as-built architectural floor and ceiling plan exhibit prepared by CSC Design for the Douglas County Sheriff's Office Law Enforcement & Adult Detention Center located at 8470 Earl D. Lee Boulevard, Douglasville, Georgia 30134. The document, dated May 13, 2026, presents existing conditions for Room S150 (Computer Room) and Room S151 (Telecom Room), along with associated electrical and mechanical spaces including the Main Electrical Room (S123) and Emergency Electrical Room (S124). The plan documents existing equipment layouts including servers, UPS systems, server racks, electrical panels, transformers, distribution equipment, HVAC units, fire alarm systems, sprinkler heads, ceiling-mounted detectors, and various wall and ceiling-mounted fixtures. Dimensions are provided for structural elements, floor chases, and clearances throughout the documented areas, with ceiling heights ranging from 9 feet 11 inches to 19 feet 6 inches depending on finish type.
The plan includes legends identifying existing fixtures such as acoustical ceilings, gypsum ceilings, exposed ceilings, light fixtures, return air terminals, supply air terminals, and fire extinguishers. The document contains a critical note stating that all measurements are based on casual visual observations and must be field-verified prior to any fabrication or installation, and that equipment names are assumptions that may not reflect proper nomenclature. The drawings are protected under United States copyright laws and cannot be reproduced or used without written consent from CSC Design. The document serves as a baseline reference for the existing infrastructure within the detention center's utility and technology spaces.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S151
TELECOM ROOM
S150
COMPUTER ROOM
FE
EXST.
MINISPLIT
FE
EXST.
AHU
EXST.
AHU
EXST.
AHU
E X
S T
. S E
R V
E R
E X
S T
. S E
R V
E R
E X
S T
. U P
S
E X
S T
. S E
R V
E R
E X
S T
. S
R A
C K
E X
S T
. S E
R V
E R
EXST. ELECTRICAL PANELS
EXST.
ELECTRICAL
PANEL
EXST. PANELS
EXST.
LENEL
PANELS
EXST. TRP
EQUIP.
40'-5"12'-0"
4" HOUSEKEEPING PAD 4" HOUSEKEEPING PAD
EXST. FIRE
ALARM PULL
0'
-2
EXST. FLOOR
CHASES
4' -0
W
X
'-0
H
4' -0
W
X
'-0
H
S124
EMERGENCY ELECTRICAL
S123
MAIN ELECTRICAL ROOM
7'
-0
22'-4" 30'-1"
'-4
9'-0" 2'-0" 28'-1" 1'-4"
'-4
8'
-0
'-0
'-0
8" +/-
EXST. DISTRIBUTION
EQUIP. ON CONC. PAD
EXST. DISTRIBUTION
EQUIP. ON CONC. PAD
EXST. DISTRIBUTION
EQUIP. ON CONC. PAD
EXST.
ELECTRICAL
PANELS
T
EXST.
TRANSFORMER
ON CONC. PAD
EXST.
CONTROL
EQUIP.
EXST.
EQUIP.
EXST.
FLOOR
CHASES
EXST.
WALL MOUNTED
EQUIP.TT
EXST.
TRANSFORMERS
ON CONC. PAD
EXST. ELECTRICAL
PANEL
EXST. ELECTRICAL
PANELS
E X
S T
S
E R
V E
R
A
C
KEXST.
WALL MOUNTED
EQUIP.
T
EXST.
TRANSFORMER
ON CONC. PAD
EXST.
ELECTRICAL PANEL
EXST.
DISCONNECT
EXST.
ELECTRICAL PANELS
FE
EXST.
POWER DISCONNECTS
T
EXST.
TRANSFORMER
ON CONC. PAD
EXST.
ELECTRICAL PANELS
EXST.
ELECTRICAL
PANELS
EXST.
DISCONNECT
EXST.
TRANSFER
SWITCH
EXST.
CONTROLS
EQUIP.
E X
S T
. T R
A N
S F
S
W
IT
C H
E S
O N
C O
N C
P
A D
E X
S T
. D
IS
T R
IB
U
T
IO
N
Q
U
IP
. O N
C O
N C
. P A
D
SOFFIT ABOVE
12'-6" A.F.F.
SOFFIT ABOVE
12'-6" A.F.F.
4'-0" W X 7'-0" H 4'-0" W X 7'-0" H
4'-0" W X 7'-0" H
EXST. CEILING AHU SERVICE RISERS EXST. CEILING AHU SERVICE RISERS EXST. CEILING AHU SERVICE RISERS
EXST. CEILING CABLE CHASES
10' - 0"ACT-03
9' - 11"ACT-03
12' - 6"GYP
19' - 6"EXPSD. 19' - 6"EXPSD.
EXST. OVERHEAD
HVAC EQUIP.
EXST. OVERHEAD
HVAC EQUIP./VENT
RCP TAG
PTD
-EXPSD
CEILING HEIGHT
CEILING FINISH
CEILING TYPE
CEILING PATTERN
CEILING TYPE LEGEND
ACT-03 24" X 48" EXISTING ACOUSTICAL CEILING
LIGHTING FIXTURES LEGEND
2X4 EXISTING LIGHT FIXTURE
EXISTING SPRINKLER HEAD
EXISTING CEILING MOUNTED DETECTOR/SENSOR
EXISTING RETURN AIR TERMINAL
EXISTING SUPPLY AIR TERMINAL
FE EXISTING FIRE EXTINGUISHER
GYP EXISTING GYP CEILING
EXISTING CEILING MOUNTED FIRE ALARM/DETECTION
EXISTING HIGH-BAY LIGHT FIXTURE
EXPSD. EXISTING EXPOSED CEILING
Phone: (770) 345-2579
135 P RICKMAN INDUSTRIAL DR.
SUITE 100 CANTON, GA 30115
© 2026, CSC Design. These drawings are protected by the copyright laws of the United States. These drawings or any part thereof may not be used for any purpose or reproduced in any form or by any means without the written consent of CSC Design.
CSC
DESIGN,
INC.
ARCHITECTS ENGINEERS&
PROJECT NUMBER:
R E
V
IS
IO
N
S
/1
/2
:4 :5
A
M Y
P ro je c ts
\2 -0
D o u g la s C o u n ty
D e te n ti o n
C e n te r A s -B u ilt
\A rc h \0
R
E V
IT
\2
-0
D o u g la s C o u n ty
D e te n ti o n C e n te r A s -B u ilt
.r v t
A-100
AS-BUILT
EXISTING FLOOR
& CEILING PLANS
C S
C .2
4.
2.
26-005
D O
U G
LA
S
C O
U N
T Y
S H
E R
IF
F
'S O
F F
IC
E
LA
W
E N
F O
R C
E M
E N
T
A D
U L T
D E
T E
N T
IO
N
C E
N T
E R
E A
R L
D . L
E E
B
LV
D D
O U
G L
A S
V
IL
L E
, G A
A-100 | 1/4" = 1'-0"1
EXISTING FLOOR PLAN
THESE PLANS AND DIMENSIONS ARE BASED ON CASUAL VISUAL
OBSERVATIONS AND MEASUREMENTS. ALL MEASUREMENTS ARE
TO BE FIELD VERIFIED PRIOR TO ANY FABRICATION OR
INSTALLATION. EQUIPMENT NAMES ARE ASSUMPTIONS AND MAY
NOT REFLECT PROPER NOMENCLATURE.
N O
D
A T
E
IS
S
U E
A-100 | 1/4" = 1'-0"2
EXISTING REFLECTED CEILING
KevinWhipple Text Box
EXHIBIT 2
| Sheets |
| A-100 - EXISTING FLOOR & CEILING PLANS |
File details come from the government source that posted it. Updated .