This document provides sample maintenance control program records for electric and hydraulic elevators. The records include checklists for monthly inspections of elevator components located in the car, machine room, top of the car, outside the hoistway, pit, and firefighters' emergency operations. The checklists cover safety components, operating controls, signs and markings, and manufacturer specific requirements. Records include spaces for initials and dates to document completion of monthly inspections. Appendices D and D1 present the sample MCP records for electric and hydraulic elevators respectively.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Maintenance Control Program Records - Electric Elevators

Bldg. # Passenger Rated load: kg Manufacturer's #:

speed: Freight Class: MARTICOLA:

INSIDE OF CAR January February March April May June July August September October November December Door reopening device * * Stop switches * * Operating control device * * Sills & car floor * * Car lighting & receptacles * * Car emergency signal * * Car door or gate * * Door closing force * * Power closing of doors or gates * * Power opening of doors or gates * * Car vision panels & glass car doors * * Car enclosure * * Emergency exit * * Ventilation * * Signs & operating devices symbols * * Rated load, platform area, & date plates * * Standby power operation * * Restricted opening of car or hoistway doors * * Car ride * * Earthquake inspection & tests (seismic risk zone 2 or greater) * *

Unique or Manufacture specific maintenance requirements (add lines as required)

MACHINE ROOM January February March April May June July August September October November December Access to machinery space * * Headroom * *

Lighting & receptacles * * Machinery space * * Housekeeping * * Ventilation * * Fire extinguisher * * Pipes, wiring, & ducts * * Guarding of exposed auxiliary equipment * *

Disconnecting means & control * * Controller wiring, fuses, grounding, etc. * * Governor, overspeed switch, & seal * * Code data plate * * Static control * * Overhead beam & fastening * * Drive machine brake * * Traction-drive machines * * Gears, bearings, & flexible couplings * *

Belt- or chain-drive machine * * Motor generator * * Absorption of regenerated power * * AC drives from a DC source * * Traction sheaves * * Secondary & deflector sheaves * * Rope fastenings * * Terminal stopping device * * Car & counterweight safeties * * Roped water hydraulic elevators * * Maintenance records * * Earthquake inspection & tests (seismic risk zone 2 or greater) * *

Unique or Manufacture specific maintenance requirements (add lines as required)

Numbering of elevators, machines, controllers & disconnected switches

Winding drum machine & slack rope device stop-motion switch, & rope fastening

TOP OF CAR January February March April May June July August September October November December Top-of-car stop switch * * Car top light & outlet * * Top-of-car operating device * * Top-of-car clearance, refuge space, & standard railing * * Normal terminal stopping device * * Final & emergency terminal stopping devices * * Car leveling & anticreep devices * * Top emergency exit * * Floor and emergency identification numbering * * Hoistway construction * * Hoistway smoke control * * Pipes, wiring, & ducts * * Windows, projections, recesses, & setbacks * * Hoistway clearance * * Multiple hoistways * * Traveling cables & junction boxes * * Door & gate equipment * * Car frame & stiles * * Guide rails, fastenings, & equipment * * Governor rope * * Governor releasing carrier * * Wire rope fastening & hitch plate * * Suspension compensation & governor systems * * Crosshead data plate & rope data tags * * Counterweight & counterweight buffer * * Counterweight safeties * * Speed test * * Compensating ropes & chains * * Earthquake inspection & tests (seismic risk zone 2 or greater) * *

Unique or Manufacture specific maintenance requirements (add lines as required)

OUTSIDE HOISTWAY January February March April May June July August September October November December Car platform guard * * Hoistway doors * * Vision panels * * Hoistway door-locking devices * * Access to hoistway * * Power closing of hoistway doors * * Sequence operation * * Hoistway enclosure * * Elevator parking devices * * Emergency doors in blind hoistways * * Standby power selection switch * *

PIT January February March April May June July August September October November December Pit access, lightning, stop switch, & condition * * Bottom clearance, runby, & minimum refuge space * * Final & emergency terminal stopping devices * * Normal terminal stopping devices * * Traveling cables * * Governor-rope tension devices * * Car frame & platform * * Car & counterweight safeties & guiding members * * Buffers & emergency terminal speed-limiting devices * * Compensating chains, ropes, & sheaves * * Car buffers * * Guiding members (trails, rollers, slides) * *

FIREFIGHTERS' SERVICE (FEO) January February March April May June July August September October November December A17.1b-1973 through A17.1b-1980 * * A17.1-1981 through A17.1b-1983 * * A17.1-1984 through A17.1a-1988 & A17.3 * * A17.1b-1989 through A17.1d-2000 * * A17.1-2000/B44-00 * * A17.1-2004/B44-04 * * A17.1-2007/B44-07 * * A17.1-2010/B44-10 * * A17.7-2013/B44-13 * * da te da te da te da te ini tia ls da te da te da te da te ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls da te da te da te da te ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _

Maintenance Control Program Records - Hydraulic Elevators

Bldg. # Passenger Rated load: kg Manufacturer's #:

speed: Freight Class: MARTICOLA:

INSIDE OF CAR January February March April May June July August September October November December Door reopening device * * Stop switches * * Operating control device * * Sills & car floor * * Car lighting & receptacles * * Car emergency signal * * Car door or gate * * Door closing force * * Power closing of doors or gates * * Power opening of doors or gates * * Car vision panels & glass car doors * * Car enclosure * * Emergency exit * * Ventilation * * Signs & operating devices symbols * * Rated load, platform area, & date plates * * Standby power operation * * Restricted opening of car or hoistway doors * * Car ride * *

MACHINE ROOM January February March April May June July August September October November December Access to machinery space * * Headroom * * Lighting & receptacles * * Machinery space * * Housekeeping * * Ventilation * * Fire extinguisher * * Pipes, wiring, & ducts * * Guarding of exposed auxiliary equipment * *

Disconnecting means & control * * Controller wiring, fuses, grounding, etc. * * Governor, overspeed switch, & seal * * Code data plate * * Hydraulic power unit * * Relief valves * * Control valves * * Tank * * Hydraulic cylinders * * Pressure switch * * Roped water hydraulic elevators * * Low oil protection * * Maintenance records * * Hydraulic control * * Earthquake inspection & tests (seismic risk zone 2 or greater) * *

Auxiliary power lowering operation * * Inspection operation with open door circuit & inspection hierarchy * *

Unique or Manufacture specific maintenance requirements (add lines as required)

Numbering of elevators, machines, controllers & disconnected switches

Emergency brake, ascending car overspeed, & unintended car movement protection

TOP OF CAR January February March April May June July August September October November December Top-of-car stop switch * * Car top light & outlet * * Top-of-car operating device * * Top-of-car clearance, refuge space, & standard railing * * Normal terminal stopping device * * Final & emergency terminal stopping devices * * Car leveling & anticreep devices * * Top emergency exit * * Floor and emergency identification numbering * * Hoistway construction * * Hoistway smoke control * * Pipes, wiring, & ducts * * Windows, projections, recesses, & setbacks * * Hoistway clearance * * Multiple hoistways * * Traveling cables & junction boxes * * Door & gate equipment * * Car frame & stiles * * Guide rails, fastenings, & equipment * * Governor rope * * Governor releasing carrier * * Wire rope fastening & hitch plate * * Suspension compensation & governor systems * * Crosshead data plate & rope dta tags * * Counterweight & counterweight buffer * * Counterweight safeties * * Speed test * * Slack rope test - roped hydraulic elevators * * Compensating ropes & chains * *

OUTSIDE HOISTWAY January February March April May June July August September October November December Car platform guard * * Hoistway doors * * Vision panels * * Hoistway door-locking devices * * Access to hoistway * * Power closing of hoistway doors * * Sequence opertion * * Hoistway enclosure * * Elevator parking devices * * Emergency doors in blind hoistways * * Standby power selection switch * *

PIT January February March April May June July August September October November December Pit access, lightning, stop switch, & condition * * Bottom clearance, runby, & minimum refuge space * * Normal terminal stopping devices * * Traveling cables * * Governor-rope tension devices * * Car frame & platform * *

Plunger & cylinder * * Car buffer (springs) * * Guiding members * * Supply piping Overspeed valve Earthquake inspection & tests (seismic risk zone 2 or greater) * * Plunger gripper * *

Unique or Manufacture specific maintenance requirements (add lines as required)

Car & counterweight safeties & guiding members including roped hydraulic elevators installed under A17.1b-1989 & later edition

FIREFIGHTERS' SERVICE (FEO) January February March April May June July August September October November December A17.1b-1973 through A17.1b-1980 * * A17.1-1981 through A17.1b-1983 * * A17.1-1984 through A17.1a-1988 & A17.3 * * A17.1b-1989 through A17.1d-2000 * * A17.1-2000/B44-00 * * A17.1-2004/B44-04 * * A17.1-2007/B44-07 * * A17.1-2010/B44-10 * * A17.7-2013/B44-13 * * sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ sig na tur e _ ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls da te da te da te da te ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls ini tia ls da te da te da te da te da te da te da te da te