02920_Lawns-Grasses_2026.pdf

PDF 150 KB Posted

Attached to
Urgent Repairs, Rehabilitation, and/or Replacement of Water and Wastewater Assets
Solicitation number
115581
Issued by
Prince George's County, Maryland

About this file

This is a Standard Specifications document for Lawns and Grasses (Section 02920) issued by the Washington Suburban Sanitary Commission (WSSC Water) in Maryland for use in water and wastewater asset repair and rehabilitation projects. The specification establishes comprehensive requirements for landscape restoration work including seed bed preparation, seeding, sodding, fertilizing, liming, and mulching across five restoration types: Type A (established lawns and public spaces using sod), Type B (sodded swales), Type C (stone-lined swales), Type D (seeded improved areas), and Type E (seeded unimproved and outfall areas). The document provides detailed technical requirements for all materials including topsoil (minimum 1.5 percent organic matter, pH 6.5 or higher), certified seed mixtures tailored to specific site conditions (dry improved areas, shaded areas, drought-prone areas, poorly drained areas, and temporary stabilization), sod specifications (3/4-inch thickness uniform cut, certified Maryland turf grass), and mulching materials (straw, jute, excelsior blanket, or wood chips). Installation procedures are specified for permanent seeding, temporary seeding, and sodding operations, with detailed preparation, application, and maintenance requirements.

All seeding, sodding, mulch application, fertilizer, lime, topsoil, and related bed preparation work are designated as incidental to the contract and will not be separately measured for payment. The specification requires submission of Certificates of Compliance for all materials prior to delivery and mandates compliance with Maryland Turf Grass Law and Regulations and Maryland Seed Law and Regulations. Contractors must obtain reference materials from the Maryland Department of Agriculture and conduct soil testing through approved laboratories to determine appropriate fertilizer recommendations before implementation. Maintenance requirements extend until written acceptance by the Engineer, including watering, inspection, repair of failures, and reseeding or resodding when turf establishment falls below required standards or exceeds 60 percent damage.

View the file

Other files

File Type Posted
Urgent_Repairs,_Rehabilitation,_and_or_Replacement_of_Water_and_Wastewater_Assets_(Addendum_#7_Revision).pdf PDF
Prince_George's_County_Wage_Determinatio.pdf PDF
Montgomery_County_Wage_Determination_8.25.26.pdf PDF
Exhibit_A_-_Company_Experience_Statement.pdf PDF
Section_VI_-_Corrosion_Details.pdf PDF
Section_VIII_-_Sediment_Control_Details.pdf PDF
WSSC_Construction_IDIQ_Terms_and_Conditions.pdf PDF
OSHA_Recordkeeping_Forms_(PDF_Fillable).pdf PDF
Section_IV_-_Water_Details.pdf PDF
Section_III_-_Sewer_Details.pdf PDF
Section_II_-_Miscellaneous_Details.pdf PDF
SCENARIO_2_Watermain_Replacement_Pkg_R.pdf PDF
SCENARIO_1_Valve_Replacement_Pkg_R.pdf PDF
SCENARIO_3_Sewer_Replacement_and_SHC_Pkg_R.pdf PDF
Section_I_-_General_Notes_0.pdf PDF
03300_Cast-in-Place_Concrete_2026.pdf PDF
02958_Pipe_Bursting_2026.pdf PDF
13110_Cathodic_Protection_2026.pdf PDF
04200_Masonry_2026.pdf PDF
02510_Water_Distribution_System_2026.pdf PDF
05500_Metal_Fabrications_2026.pdf PDF
Section_VII_-_Pressure_Sewer.pdf PDF
03400_Precast_Concrete_Underground_Structures_2026.pdf PDF
Section_IX_-_Procurment_and_Manufacturing_Details_(1).pdf PDF
02315_Earthwork_for_Pipeline_Construction_2026.pdf PDF
02955_Sewer_Mains_Lateral_Rehabilitation_by_Lining_2026.pdf PDF
13112_Impressed_Current_Cathodic_Protection_for_Water_Sewer_Pipelines_2026.pdf PDF
02957_Sewer_Manhole_Rehabilitation_2026.pdf PDF
02530_Sanitary_Sewage_System_2026.pdf PDF
02960_Temporary_Bypass_Pumping_System_2026.pdf PDF
02370_Slope-Watercourse_Protection_2026.pdf PDF
02441_Microtunneling_2026.pdf PDF
Sol_Urgent_Repairs_Exmaple_Invoice.xlsx XLSX spreadsheet
01330_Submittal_Procedures_2026.pdf PDF
02820_Fences-Gates_2026.pdf PDF
02930_Exterior_Plants_2026.pdf PDF
02950_Paving_Requirements_2026.pdf PDF
02533_Pressure_Sewer_System_2026.pdf PDF
02956_CCTV_Inspection_of_Sewer_Mains,_Manholes_and_Laterals_2026.pdf PDF
02959_Sewer_Main_and_Lateral_Connection_Sealing_2026.pdf PDF
02230_Site_Clearing_2026.pdf PDF
02512_Cleaning-Lining_Water_Mains_2026.pdf PDF
ESC_Minor_Utility_Permit,_Health_and_Safety_Qualification_Questionaire,_and_Example_Health_and_Safety_Plan_outline.pdf PDF
02510_Water_Distribution_System_Contractor_Furnishes_All_Materials_2026.pdf PDF
02511_Chlorination_and_Dechlorination_2026.pdf PDF
02446_Horiz_Directional_Drilling_2026.pdf PDF
01500_Temp_Facilities_Controls_2026.pdf PDF
02445_Boring-Jacking_2026.pdf PDF
01110_Summary_of_Work_2026.pdf PDF
00600_TOC_Specs_2026.pdf PDF
Show 40 more

Latest 50 of 58 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

02920-1 2026

STANDARD SPECIFICATIONS

SECTION 02920

LAWNS AND GRASSES

PART 1 GENERAL

1.1 DESCRIPTION

Section includes requirements for preparation of seed and sod bed, seeding, sodding, fertilizing, liming, and mulching to limits shown, and as required for restoration and restabilization of disturbed areas, at Engineer’s direction.

1.2 RESTORATION

As defined below, and when noted in Restoration Schedule on Drawings.

Type A: Sod for established lawns, park lawns, and frequently mowed public spaces.

Type B: Sod for sodded swales.

Type C: Surge stone for seeded and stone lined swales.

Type D: Seed for improved areas.

Type E: Seed for unimproved and outfall areas.

Type F: Development sites with existing stabilization of temporary mulch or planted seed.

a. Restore in kind and maintain.

Service Connection Contracts (SC, LC, AC) and Sewer Rehabilitation Contracts as specified herein.

Type A.

Type D.

1.3 SUBMITTALS

Submit following Section 01450.

Certificates of Compliance Before Delivery of Materials:

a. Topsoil.

b. Seed.

c. Sod.

d. Fertilizer.

e. Lime.

1.4 REFERENCE DOCUMENTS

Obtain and maintain at work site a copy of Maryland Turf Grass Law and Regulations and Maryland Seed Law and Regulations, available from:

02920-2 2026

Maryland Department of Agriculture Turf and Seed Regulatory 50 Harry S. Truman Parkway Annapolis, Maryland 21401 Phone (410) 841-5960

PART 2 PRODUCTS

2.1 TOPSOIL

Properties Fertile natural surface agricultural soil capable of sustaining vigorous plant growth.

Containing not less than 1-1/2 percent organic matter as determined by MSHA

Standard Method of Test.

pH value of not less than 6.5.

Free of stones, roots, rubbish, and other objectionable materials such as Bermuda grass, poison ivy, and kindred roots, and material harmful to plant growth.

Sufficient pore space to permit adequate root penetration.

Meet analysis of sand, silt, and clay when determined following AASHTO M146 with these exceptions:

Percent Passing by Weight Minimum Maximum

Sand 20 75 Silt 10 60 Clay 5 30

Topsoil available on site that meets above specified requirements may be utilized with Engineer’s approval.

2.2 SPECIAL PURPOSE TOPSOIL

Hand spreadable and meeting requirements listed above for topsoil and following gradation:

Sieve Minimum Percent

Passing by Weight 2-inch 100 No. 4 90 No. 10 80

Topsoil available on site that meets above specified requirements for special purpose topsoil may be utilized with Engineer’s approval.

02920-3 2026

2.3 COMPOSTED SLUDGE

May be used instead of topsoil following requirements specified herein.

Composition: Mixture of sewage sludge and bulking agent, such as wood chips, subjected to aerobic decomposition (composting).

Meet guidelines for destruction of primary pathogenic organisms and heavy metals limitations as set forth by Maryland Department of Health and Mental Hygiene.

Handle and transport under guidelines in Department of the Environment Code of Maryland Regulations 26.04.06.

Meet guidelines for nutrient content and application rates as outlined in Maryland Department of the Environment Standards and Specifications for Soil Erosion and Sediment Control.

2.4 SEED

Certification: Unless otherwise specified herein, certified by Maryland Department of Agriculture and following requirements of Maryland Seed Law and Regulations.

For dry and semishady improved areas mowed regularly: Sow following mixtures at 195 pounds per acre or 4.5 pounds per 1,000 square feet between March 1 and May 31 and between August 15 and October 31.

TYPE OF GRASS PERCENT CERTIFIED SPECIES

Tall Fescue 90-100 Adventure, Apache, Arid, Falcon, Finelawn I, or Rebel II.

Kentucky Bluegrass 0-10 Common, Kenblue, Vica, Ram 1, or Monopoly.

For dry, heavily shaded improved areas mowed regularly: Sow mixture at 175 pounds per acre or 4 pounds per 1,000 square feet between March 1 and May 31 and between August 15 and October 31.

Tall Fescue 65 Adventure, Apache, Arid, Falcon, Finelawn I, or Rebel II.

Perennial Ryegrass 10 All-Star, Blazer, Manhattan, Palmer, Pennant, Pennfine, Premier, Prelude, Regal, or Repell.

Creeping Red Fescue and/or Chewings Fescue

25 Penlawn, Flyer, Longfellow, Victory, or Jamestown.

For unimproved drought-prone areas not to be mowed or mowed infrequently: Sow mixture at 175 pounds per acre or 4 pounds per 1,000 square feet between March 1 and May 31 and between August 15 and October 31.

02920-4 2026

Tall Fescue 80 Kentucky 31 Perennial Ryegrass 20 Common

For unimproved areas that are poorly drained and subject to frequent flooding: Sow mixture at 130 pounds per acre or 3 pounds for 1,000 square feet between March 1 and May 31 and between August 15 and October 31.

Tall Fescue 75 Kentucky 31 Reed Canarygrass 25 Common

Temporary grass stabilization: Use 1 of following, but not in maintained turf areas.

TYPE OF GRASS SOWING INSTRUCTIONS

Barley or Annual Ryegrass

Sow mixture at 50 pounds per acre or 1 pound per 1,000 square feet between March 1 and May 31 and between August 15 and October 15.

Foxtail Millet Sow mixture at 50 pounds per acre or 1 pound per 1,000 square feet between May 31 and August 15.

Nontidal wetlands and nontidal wetlands buffers: Use 1 of following:

TYPE OF GRASS SOWING INSTRUCTIONS

Annual ryegrass;

Millet; Barley, Oats; Rye.

100 percent of 1 of the listed. Follow Maryland Standards and Specifications for Soil Erosion and Sediment Control, MDE, WMA for seeding rates, zones, and periods. Other non persistent vegetation approved by Maryland Department of Natural Resources, Nontidal Wetlands Division.

2.5 SOD

Grade: Certified or Approved as designated by Maryland Department of Agriculture and following requirements of Maryland Turf Grass Law and Regulations.

Machine cut sod at uniform thickness of 3/4 inch ± 1/4-inch, excluding top growth and thatch.

Use individual sod pieces strong enough to support their own weight when lifted by ends.

Broken pads, irregularly shaped pieces, and torn or uneven ends will not be acceptable.

Lay sod between September 15 and May 15. Do not lay on frozen ground.

Replacement:

02920-5 2026

For replacing previously established turf, use sod similar to what existed before construction.

For sod placed where no grass existed before construction or replacing lawn consisting mainly of coarse textured grass without dominant species, use Maryland Certified Sod of Tall Fescue 100 percent Certified Adventure, Apache, Arid, Bonanza, Falcon, Finelawn, Jaquar, Mustang, Olympic, or Rebel.

For sod replacing lawn consisting mainly of fine textured grass without dominant species, use Maryland Certified sod of Kentucky Bluegrass 100 percent certified Aspen, Blacksburg, Bristol, Cheri, Eclipse, Georgetown, Gnome, Haga, Merit, Midnight, Plush, Trenton, or Victa.

2.6 FERTILIZER

Uniform composition, free flowing and delivered to site fully labeled according to applicable state fertilizer laws and bearing name, trade name, or trademark and warranty of producer.

Submit soil samples to approved soils testing laboratory for fertilizer recommendations.

Submit recommendations and receive Engineer’s approval before implementation.

Unless otherwise directed, fertilize at following rates:

Temporary Seeding: 10-10-10 or equivalent at rate of 600 pounds per acre or 15 pounds per 1,000 square feet.

Permanent Seeding: 1000 pounds per acre of 10-20-20 or equal.

Sodding:

a. Immediately before sod placement, apply 3.5 pounds of slow release nitrogen per 1,000 square feet.

b. Slow release nitrogen: Approximately 1/3 immediately available and 2/3 water insoluble, such as Urea formaldehyde or isobutyledene urea.

c. Rate: 15 pounds of 10-20-10 per 1,000 square feet after sodding.

2.7 LIME

Contents: Ground limestone containing at least 50 percent total oxides (calcium oxide plus magnesium oxide).

Limestone: Ground to fineness so that at least 50 percent will pass through 100 mesh sieve and 98 percent will pass through 20 mesh sieve.

Rate: 2 tons per acre, 100 pounds per 1000 square feet.

2.8 MULCH

For Protection of Permanent Seeding:

Straw: Clean, weed free, unrotted, applied at rate of not less than 100 pounds per

1,000 square feet, 2 tons per acre, and anchored with 1 of following methods.

02920-6 2026

a. Mulch anchoring tool for flat slopes, mulch nettings, and cut back or liquid binders listed following manufacturer's recommendation.

b. Acrylic DLR (Agro-Tack).

c. DCA-70.

d. Petroset.

e. Terra Tax II.

f. Terra Tack AR.

g. Or equal.

Mulch: Jute or excelsior blanket.

Wood Chips: Coverage 1-1/2 inches deep.

Mulch Utilized as Temporary Protection and Stabilization: Follow above materials requirements, except Engineer will set rate of application.

PART 3 EXECUTION

3.1 PERMANENT SEEDING

Preparation.

Harrow, disc, or otherwise loosen subsoil to depth of 4 inches.

Spread topsoil or composted sludge evenly over prepared subsoil to following depths.

a. Topsoil:

1) Slopes 3:1 or steeper: 2 inches after compaction.

2) Slopes flatter than 3:1: 4 inches after compaction.

b. Composted Sludge:

1) All areas: 2 inches after compaction.

Where existing topsoil does not meet these requirements, provide required topsoil to meet above minimum thicknesses.

Remove objectionable material such as stones 2 inches or larger, clods, brush, roots, and trash from top 4 inches of soil.

Perform harrowing, discing, scarifying, and raking on contour of slopes steeper than 3:1.

Amendments:

Apply lime and fertilizer at rates specified in PART 2, PRODUCTS, and thoroughly mix into top 6 inches.

a. When composted sludge is used instead of topsoil, lime and fertilizer may be eliminated.

b. Scarify area and rake until surface is leveled to give a maximum of 2 inches in variation, and soil is easily crumbled and uniform fine texture.

Seed Application:

Apply mixture uniformly with mechanical power driven seeders, mechanical cyclone hand seeders or hydroseeding equipment.

Slurry for hydroseeder may contain seed and fertilizer only.

02920-7 2026

Disc seed 1 inch into soil in floodplain areas.

Rake, roll, or drag seedbed in all other areas, if hydroseeder or cyclone seeder is used.

Moisten seedbed during periods of drought and/or high temperatures.

Mulch Application:

Apply at rates specified in PART 2 PRODUCTS herein.

Anchor as specified in PART 2 PRODUCTS herein.

3.2 TEMPORARY SEEDING

Preparation:

Loosen top 2 inches of seedbed.

Apply lime and fertilizer at rates specified in PART 2 PRODUCTS.

Seed Application: Follow application for permanent seeding.

Mulch Application: Follow application for permanent mulching.

3.3 SODDING

Preparation:

Harrow, disc, or otherwise loosen subsoil to depth of 6 inches.

Harrow, disc, scarify, and rake on contour of slopes steeper than 3:1.

Remove objectionable material such as stones, clods, brush, roots, and trash from top 4 inches of soil.

Amendments:

Apply lime and fertilizer at rates specified in PART 2, PRODUCTS, and thoroughly mix into loosened subsoil.

Scarify area and rake until surface is leveled to a maximum of 2 inches in variation, and soil is easily crumbled and uniform fine texture.

Sodding:

Lay between September 15 and May 15.

Deliver to site within 24 hours, and install within 36 hours, after cutting.

During wet weather, dry sod sufficiently to prevent tearing during handling and placing.

a. During dry weather, water sod sufficiently before lifting to insure its vitality and to prevent dropping off of soil during handling.

Desiccated sod will be rejected; replace at no cost to the Commission.

Place sod in straight lines parallel to one another.

a. Stagger lateral joints and butt tight.

b. On slopes 5:1 and steeper place sod with long edges parallel to contour starting at top of slope.

02920-8 2026

c. In drainage ditches and sodded channels, place sod with long edge parallel to flow of water.

On slopes 2:1 and steeper and in surface drainage V-shaped or flat bottomed ditches, stake each strip of sod with at least 2 stakes, spaced not more than 2 feet apart, or wire staples.

Immediately after completing section of sodding, roll, tamp, and water until underside of sod pad and soil surface beneath it are thoroughly wet and in contact with each other to eliminate air pockets.

Completion of placing, rolling, tamping, and watering: Within 8-hour period.

Moisten dry sod bed during periods of drought or high temperatures.

3.4 MULCH ONLY

Grade as required.

Place and anchor mulch only at rates specified in PART 2, PRODUCTS, where indicated and directed by Engineer.

3.5 TIME RESTRICTIONS

When permanent seeding or sodding is specified or directed, and is not allowed because of time restrictions specified above, utilize 1 or more of following methods to prevent erosion and sedimentation until permanent seeding or sodding is allowed.

Place and anchor straw mulch or wood chips.

Apply temporary seeding and mulch.

Prepare soil as for permanent seeding and then mulch as specified herein;

overseed during next seasonal seeding period.

Provide other erosion control measures acceptable to Engineer.

Remove straw or wood chips used as temporary mulch or work into subsoil minimum depth of 6 inches before initiation of permanent seeding or sodding application.

3.6 MAINTENANCE OF SEEDED AND SODDED AREAS

Maintain seeded and sodded areas until accepted in writing by Engineer.

Water seeded and sodded areas as necessary to establish growth.

Inspect seeded and sodded areas for failures and necessary repairs.

Provide replacements during specified planting seasons.

When Engineer determines stand of turf is inadequate:

Overseed and fertilize using 1/2 of rates originally applied.

Resod.

When Engineer determines stand is over 60 percent damaged:

02920-9 2026

Reestablish following original lime, fertilizer, and seed.

Prepare sod bed following seeding or sodding recommendations.

PART 4 MEASUREMENT AND PAYMENT

4.1 SEEDING AND SODDING

Seeding, sodding, mulch, fertilizer, lime, topsoil, and preparation of seed and sod bed to limits indicated, as directed by Engineer, and to repair damage caused by Contractor's operations, will not be measured for payment, but will be considered incidental to Contract.

**WSSC**

1.1 DESCRIPTION
1.2 RESTORATION
1.3 SUBMITTALS
1.4 REFERENCE DOCUMENTS
2.1 TOPSOIL
2.2 SPECIAL PURPOSE TOPSOIL
Sieve
2.3 COMPOSTED SLUDGE
2.4 SEED
2.5 SOD
2.6 FERTILIZER
2.7 LIME
2.8 MULCH
3.1 PERMANENT SEEDING
3.2 TEMPORARY SEEDING
3.3 SODDING
3.4 MULCH ONLY
3.5 TIME RESTRICTIONS
3.6 MAINTENANCE OF SEEDED AND SODDED AREAS
4.1 SEEDING AND SODDING