015816 Temp Int Signage 08-11 Edited 121511.pdf
PDF 65 KB Posted
- Attached to
- Z1DA--FIRE DAMPERS -Repair, Install, Inspect and Testing Federal contract opportunity
- Solicitation number
- 36C24221B0065
About this file
This document contains a public synopsis for an upcoming federal solicitation as well as specifications for repairing, installing, inspecting, testing, and decommissioning fire dampers at a Department of Veterans Affairs medical center in New York. The solicitation will require contractors to prepare shop drawings and as-built drawings of approximately 350 fire dampers located in two buildings on the medical center campus. The contractor will inspect and test all fire dampers for accessibility and function, and provide access where needed through installation of access panels and doors. The contractor must also research existing drawings and verify damper locations. The estimated cost range for the project is $200,000 to $500,000. The solicitation is anticipated to be issued on August 27, 2021, and the project completion period will be 360 calendar days from the notice to proceed. The solicitation will be set aside exclusively for verified veteran-owned small businesses.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Sheet -36C24221B0065 Rev.pdf | ||
| 36C24221B0065 0004.docx | DOCX document | |
| 36C24221B0065 0003.docx | DOCX document | |
| Site Visit - Sign In 36C24221B0065 Fire Damper.pdf | ||
| Bid Sheet -36C24221B0065.pdf | ||
| RFIs -36C24221B0065 Answers.pdf | ||
| VA NOTICE OF LIMITATIONS ON SUBCONTRACTING CERTIFICATION.pdf | ||
| 36C24221B0065 0002.docx | DOCX document | |
| 36C24221B0065 0001.docx | DOCX document | |
| Building 1.pdf | ||
| 017419 Const Waste management 09-10 edited 121511.pdf | ||
| 014529 Testing Lab Srvcs 05-09 - Edited - 121511.pdf | ||
| Building 6.pdf | ||
| 015719Temp Env Cntrls 01-11 - Edited 121511.pdf | ||
| 013323 Shop Dwgs Product Data and Samples - Edited - 121511.pdf | ||
| 010000 Gen Req 6-11- Edited -121311.pdf | ||
| Fire Dampers Report - 2014.pdf | ||
| DB Wage Determination dtd 10-22-2021.pdf | ||
| 014219 Ref Standards 09-11 - Edited - 121511.pdf | ||
| 36C24221B0065.docx | DOCX document |
Show all 20
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
08-11
Repair Fire Dampers/Testing last edited 1/4/12
01 58 16 - 1
SECTION 01 58 16
TEMPORARY INTERIOR SIGNAGE
PART 1 GENERAL
DESCRIPTION
This section specifies temporary interior signs.
PART 2 PRODUCTS
2.1 TEMPORARY SIGNS
A. Fabricate from 50 Kg (110 pound) mat finish white paper.
B. Cut to 100 mm (4-inch) wide by 300 mm (12 inch) long size tag.
C. Punch 3 mm (1/8-inch) diameter hole centered on 100 mm (4-inch) dimension of tag. Edge of Hole spaced approximately 13 mm (1/2-inch) from one end on tag.
D. Reinforce hole on both sides with gummed cloth washer or other suitable material capable of preventing tie pulling through paper edge.
E. Ties: Steel wire 0.3 mm (0.0120-inch) thick, attach to tag with twist tie, leaving 150 mm (6-inch) long free ends.
PART 3 EXECUTION
3.1 INSTALLATION
A. Install temporary signs attached to room door frame or room door knob, lever, or pull for doors on corridor openings.
B. Mark on signs with felt tip marker having approximately 3 mm (1/8-inch) wide stroke for clearly legible numbers or letters.
C. Identify room with numbers as designated on floor plans.
3.2 LOCATION
A. Install on doors that have room, corridor, and space numbers shown.
B. Doors that do not require signs are as follows:
1. Corridor barrier doors (cross-corridor) in corridor with same number.
2. Folding doors or partitions.
3. Toilet or bathroom doors within and between rooms.
4. Communicating doors in partitions between rooms with corridor entrance doors.
5. Closet doors within rooms.
C. Replace missing, damaged, or illegible signs.
- - - E N D - - -