Z1FZ--Service 463-24-LUMPSUM 944 Boiler Replacement
Closed Solicitation Posted
- Solicitation number
- 36C26024R0097
- Agency
-
Veterans Integrated Service Network 20
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- No set-aside
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of Veterans Affairs Veterans Health Administration is seeking a contractor to replace the boiler system in Building 944 at the Anchorage VA Medical Center in Anchorage, Alaska. The project involves the removal and disposal of the current boiler and the installation of a new cast iron boiler with a minimum net output of 199 MBH. Key requirements include providing submittals for review, a project schedule, and a 1-year warranty. Proposals will be evaluated based on a combination of price and technical/management approach factors, which are of approximately equal importance. The proposal due date is July 24, 2024 at 8:00am PST.
This is a 100% set-aside for Service-Disabled Veteran-Owned Small Businesses (SDVOSBs). The estimated contract value is $463,240 on a lump sum basis. The period of performance is 60 days. The place of performance is the Anchorage VA Medical Center in Anchorage, Alaska.
Notice text
4 versions
Update #4 · Latest ·
36C26024R0097, Amendment 0001 CONTINUATION PAGE It has been determined necessary and in the best interest of the Government to make the following clarifications/revisions to solicitation 36C26020Q0015. Questions and Answers: Q: The existing boiler is glycol. Do you want the replacement boiler to be a glycol or a water boiler, like the one in the adjacent tenement? There were past discussions of matching the two boilers for service and maintenance efficiency. If it is decided to match boilers, can you provide the data for the other boiler. A: Match existing glycol system. This project is independent of other properties. Q: The location of the existing boiler makes it difficult to replace and service. Can the boiler be relocated within the room for ease of installation and maintenance? A: Yes, the boiler can be relocated for ease of access and maintenance. Coordinate with VA FMS prior to final location determination.  Q: Please confirm the intent of the flue replacement is from the existing tee to the boiler. A: Confirmed. A flue submittal is not necessary. Q: Please confirm that the existing glycol make up tank is to be reused. A: Replace existing Glycol tank and provide a submittal for review prior to work. Eliminate condensate neutralizer from scope of work.Â
Update #3 ·
36C26024R0097, Amendment 0001
CONTINUATION PAGE
It has been determined necessary and in the best interest of the Government to make the following clarifications/revisions to solicitation 36C26020Q0015.
Questions and Answers:
Q: The existing boiler is glycol. Do you want the replacement boiler to be a glycol or a water boiler, like the one in the adjacent tenement? There were past discussions of matching the two boilers for service and maintenance efficiency. If it is decided to match boilers, can you provide the data for the other boiler.
A: Match existing glycol system. This project is independent of other properties.Â
Q: The location of the existing boiler makes it difficult to replace and service. Can the boiler be relocated within the room for ease of installation and maintenance?
A: Yes, the boiler can be relocated for ease of access and maintenance. Coordinate with VA FMS prior to final location determination. Â
Q: Please confirm the intent of the flue replacement is from the existing tee to the boiler.
A: Confirmed. A flue submittal is not necessary.Â
Q: Please confirm that the existing glycol make up tank is to be reused.
A: Replace existing Glycol tank and provide a submittal for review prior to work. Eliminate condensate neutralizer from scope of work.Â
Update #2 ·
Description for file.
Update #1 ·
Solicitation Description
Files
| File | Type | Posted |
|---|---|---|
| Attachment 1 - 944 Boiler SOW Rev. 01, 17-18-2024.docx | DOCX document | |
| 36C26024R0097 0004.docx | DOCX document | |
| 36C26024R0097 0003.docx | DOCX document | |
| 36C26024R0097 0002.docx | DOCX document | |
| SOLICITATION-DESCRIPTION white text.docx | DOCX document | |
| 36C26024R0097 0001.docx | DOCX document | |
| Attachment 3 - Divisional Price Breakout.xlsx | XLSX spreadsheet | |
| Attachment 2 - Wage Determination Anchorage County 6.14.2024.txt | TXT text file | |
| Attachment 4 - Contractor Rules of Behavior.pdf | ||
| Attachment 1 - SOW 944 Boiler 6-11-2024.docx | DOCX document | |
| 36C26024R0097.docx | DOCX document |
Show all 11
Notice history
| Notice | Type | Posted |
|---|---|---|
| This notice | Solicitation | |
| Z1FZ--Service 463-24-LUMPSUM 944 Boiler Replacement | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Z1DA--Project 695-24-107 Replace Boilers 4 and 5 Clement J. Zablocki, VA Medical Center 5000 West National Avenue Milwaukee, WI 53295 | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| Z1DA--FY27 NRM - Replace B98 and B88 Boiler and Sump Pumps | Veterans Integrated Service Network 21 | No set-aside | |
| Z1DA--550-20-121 Demo Old Boiler Plant B100 (CON) | Veterans Integrated Service Network 12 | Service-Disabled Veteran-Owned Small Business | |
| Z2NZ--Turn Key Chiller Equipment (Purchase and Install) | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| Y1DZ--replace chilled water pump at the boiler plant | Veterans Integrated Service Network 2 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity