Z1DZ--402-22-755 Replace Laundry HVAC

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C24125R0095
Agency
Responses due
Set-aside
Service-Disabled Veteran-Owned Small Business

Opportunity facts

Place of performance
Augusta, Maine 04330, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 1 is seeking contractors to provide labor, materials, and services for the repair and replacement of the HVAC system in the laundry rooms at the VAMC Maine, Togus Campus in Augusta, Maine. This comprehensive project involves replacing an 80-ton condensing unit, installing a new air handling unit, upgrading electrical systems, constructing a new Clean Linen Storage Room, and implementing security improvements including access controls and safety film on windows. The work must be performed while maintaining operational laundry services, with construction scheduled during normal business hours (7 AM to 3:30 PM, Monday-Friday) and laundry operations typically ending at 1:30 PM daily. The evaluation will use a tiered process giving preference first to Service-Disabled Veteran-Owned Small Businesses (SDVOSBs), followed by Veteran-Owned Small Businesses (VOSBs), Women-Owned Small Businesses (WOSBs), other small businesses, and finally large businesses. The original solicitation was posted on May 8, 2025, with the proposal submission deadline extended from June 19 to June 20, 2025, at 3 PM ET due to a holiday conflict.

While the solicitation description indicates it is set aside for Service-Disabled Veteran-Owned Small Businesses, the accompanying documents clarify that the requirement is actually open to all firms without set-aside, utilizing the tiered evaluation preference system instead. The project involves significant electrical work with a total new mechanical connected load calculated at 176.47 kVA and a grand total building demand of 246.26 kVA, utilizing an existing 300.00 kVA service transformer. Key technical components include comprehensive roofing work with modified bituminous sheet roofing systems, installation of DRI-STEEM Steam-to-Steam Humidifier units, and Bell & Gossett Series e-80 pumps for hydronic systems. The contractor will be required to comply with VHA Directive 1061 for preventing Legionella disease and scald injury from water systems, including developing Cooling Tower Management Plans and conducting regular testing protocols. Work will be performed at the Togus VA Medical Center campus in Augusta, Maine, with specific attention to maintaining truck access and minimizing impact to parking areas during construction.

Notice text

2 versions

Update #2 · Latest ·

Provision of labor, materials and services to perform repair and replacement of the HVAC system located in the laundry rooms of VAMC Maine, Togus Campus. Please see the attached statement of work and solicitation documents for more information. This requirement is open to all firms without set-aside. A tiered evaluation process will be used, with preference in the evaluation of proposals given to SDVOSBs, followed by VOSBs, then WOSBs, then all other small business, with the least amount of preference given to large businesses. Please see the Instructions to Offers included with the solicitation for more information regarding the evaluation preferences and applicability of clauses in this solicitation to business concerns.

Update #1 ·

Provision of labor, materials and services to perform repair and replacement of the HVAC system located in the laundry rooms of VAMC Maine, Togus Campus. Please see the attached statement of work and solicitation documents for more information. This requirement is open to all firms without set-aside. A tiered evaluation process will be used, with preference in the evaluation of proposals given to SDVOSBs, followed by VOSBs, then WOSBs, then all other small business, with the least amount of preference given to large businesses. Please see the Instructions to Offers included with the solicitation for more information regarding the evaluation preferences and applicability of clauses in this solicitation to business concerns.

Files

File Type Posted
36C24125R0095 0004.pdf PDF
Roof Warranty.pdf PDF
Additonal Roof Specs.pdf PDF
36C24125R0095 0003.pdf PDF
36C24125R0095 Amendment 0002.pdf PDF
402-22-755 Replace Laundry HVAC Site Visit Sign in Sheet.pdf PDF
36C24125R0095 Amendment 0001.pdf PDF
Additional Roof Specs - HVAC .pdf PDF
Previous Solicitation RFIS - Laundry HVAC .docx DOCX document
SOW Attachment 12 - VHA Directive 1061 .pdf PDF
SOW Attachment 10- Narrative-min - Part3 .pdf PDF
SOW Attachment 08A- 402-22-755- Specs Volume I .pdf PDF
SOW Attachment 07 - Local Requirements.pdf PDF
SOW Attachment 02 402-22-755 Replace Laundry HVAC - ICRA.pdf PDF
Past Performance Questionnaire - Replace Laundry HVAC .docx DOCX document
04 - SOW - 402-22-755 Replace Laundry HVAC.pdf PDF
Site Investigation Report - Laundry HVAC.pdf PDF
Pre-Award Contractor Eval Safety Form - Replace Laundry HVAC .docx DOCX document
ME20250005 01032025.pdf PDF
SOW Attachment 11- Laydown Area.pdf PDF
SOW Attachment 10- Narrative-min - Part2 .pdf PDF
SOW Attachment 09- 402-22-755 - Drawings.pdf PDF
SOW Attachment 08B- 402-22-755- Specs Volume II .pdf PDF
SOW Attachment 06 - Sensitive Infrastructure Data Clarification FOUO.docx DOCX document
SOW Attachment 04A Seasonal Influenza with Vaccines .pdf PDF
SOW Attachment 03 - Togus Campus Map.pdf PDF
SOW Attachment 01 402-22-755 Replace Laundry HVAC - PCRA .pdf PDF
Roof Warranty - Replace Laundry HVAC.pdf PDF
36C24125R0095_2.docx DOCX document
SOW Attachment 10- Narrative-min - Part4 .pdf PDF
SOW Attachment 10- Narrative-min - Part1.pdf PDF
SOW Attachment 08C- 402-22-755- Specs Volume III .pdf PDF
SOW Attachment 05-PIV Badge Template .pdf PDF
Show all 33

Notice history

Notice Type Posted
Z1DZ--402-22-755 Replace Laundry HVAC Award Award Notice
This notice Latest solicitation Solicitation
Z1DZ--Copy of 402-22-755 Replace Laundry HVAC Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J065-- HVAC upgrades at VA Loch Raven location Department of Veterans Affairs Vamc Baltimore, Maryland 21201, United States · NAICS 561210 Veterans Integrated Service Network 5 Total Small Business
Z2NZ--Turn Key Chiller Equipment (Purchase and Install) Pineville, Louisiana 71360, United States · NAICS 238220 Veterans Integrated Service Network 16 Service-Disabled Veteran-Owned Small Business
Y1DA--561-24-600 Upgrade Mechanical Systems-C Level Department of Veterans Affairs New Jersey VA Health Care System East Orange, New Jersey 07018, United States · NAICS 238220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business
J041--Condensate Pump Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
Replace B28 AHU 1, 4, 18, 9A, 9B, OR Chiller Amarillo, Texas 79106, United States · NAICS 238220 Veterans Integrated Service Network 17 Service-Disabled Veteran-Owned Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors