Y1DZ-- 589A5-15-117B, CORRECT SPS DESIGN ISSUES New (VA-21-00070541)

Closed Pre-Solicitation Posted

Solicitation number
36C25521R0102
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Colmery-O'Neil VA Medical Center 2200 Gage Blvd. Topeka, Kansas 66622, United States

Notice details come from SAM.gov. Updated .

About this opportunity

This pre-solicitation notice is seeking proposals for project 589A5-15-117B to correct design issues in the sterile processing services at the Colmery O'Neil VA Medical Center in Topeka, Kansas. The scope of work involves modifying HVAC systems and ductwork. Proposals will be evaluated based on three technical factors including relevant past performance, technical construction experience, and personnel qualifications. The response deadline is September 15, 2021.

The solicitation has no set-aside designations. The NAICS code is 236220 for commercial and institutional building construction. The estimated value is between $1 million to $5 million to be completed within 182 calendar days of the notice to proceed. Key aspects of the work include modifying existing air handling units and supply ductwork, adding return air grilles, modifying supply and exhaust ductwork for the cart wash area, removing abandoned HVAC components, and connecting sterilizers to the central steam system.

Notice text

2 versions

Update #2 · Latest ·

This notice is posted IAW Far 19.804.2. This project proposal is competitively open to responsible contractors. Solicitation: 36C25521R0102, Contract Type: Firm Fixed Price, NAICS: 236220, Commercial and Institutional Building Construction, Business size is $36.5M, Title-Description of Requirement: PN 589A5-15-117B SPS Design Correction The Sterile Processing Services Design Correction project is a renovation project at Colmery O Neil VA Medical Center in Topeka, KS. The scope includes the following items: provide all labor, materials and equipment to modify existing AHU, supply ductwork to CAV-3 as indicated on as required by drawings, add return air grilled in vestibule B011 into the existing exhaust duct, modify supply and exhaust ductwork to Cart Wash, remove all abandoned DX coil and components, change SPS sterilizers form the standing boilers to central steam, install new HM doorway, install N+1 exhaust fan addition and provide full testing , adjusting, and balancing (TAB) of the HVAC system in accordance with drawings and specification to replace and return to service the sterile processing services at Topeka VAMC. Completion time from NTP is undetermined but estimated to be 182 calendar days. The facility location: VISN 15/ Topeka VAMC, 2200 Gage Blvd., Topeka, KS 66622. The estimated cost magnitude is between $1,000,000 and $5,000,000. Proposal will be posted on or about July 30, 2021.

Update #1 ·

This notice is posted IAW Far 19.804.2. This project proposal is competitively open to responsible contractors. Solicitation: 36C25521R0102, Contract Type: Firm Fixed Price, NAICS: 236220, Commercial and Institutional Building Construction, Business size is $36.5M, Title-Description of Requirement: PN 589A5-15-117B SPS Design Correction The Sterile Processing Services Design Correction project is a renovation project at Colmery O Neil VA Medical Center in Topeka, KS. The scope includes the following items: provide all labor, materials and equipment to modify existing AHU, supply ductwork to CAV-3 as indicated on as required by drawings, add return air grilled in vestibule B011 into the existing exhaust duct, modify supply and exhaust ductwork to Cart Wash, remove all abandoned DX coil and components, change SPS sterilizers form the standing boilers to central steam, install new HM doorway, install N+1 exhaust fan addition and provide full testing , adjusting, and balancing (TAB) of the HVAC system in accordance with drawings and specification to replace and return to service the sterile processing services at Topeka VAMC. Completion time from NTP is undetermined but estimated to be 182 calendar days. The facility location: VISN 15/ Topeka VAMC, 2200 Gage Blvd., Topeka, KS 66622. The estimated cost magnitude is between $1,000,000 and $5,000,000. Proposal will be posted on or about July 30, 2021.

Files

Show all 14

Similar open opportunities

Opportunity Agency Set-aside Responses due
Y1DZ--PCAC EHRM Infrastructure Upgrades Construction - Togus VAMC (VA-27-00009716) Industry Day: 810 Eastern Avenue Augusta ME 04330 · NAICS 236220 VA Technology Acquisition Center No set-aside
Y1DA--CON NRM 531-25-102 | Expand Emergency Room Boise, Idaho, United States · NAICS 236220 Veterans Integrated Service Network 20 Service-Disabled Veteran-Owned Small Business
Z1DA--Sources Sought Notice/Market Research Project: Renovate SPS Phase 3 Central Virginia VA Healthcare System Cvhcs Richmond Virginia 23249 · NAICS 236220 Veterans Integrated Service Network 6 No set-aside
C1DA--578-27-003 - Renovate A Section First Floor of Building 1 - Design FY27 Edward Hines Jr. VA Hospital Hines, Illinois 60141, United States · NAICS 541310 Veterans Integrated Service Network 12 Service-Disabled Veteran-Owned Small Business
Y1DZ--replace chilled water pump at the boiler plant Department of Veterans Affairs Network Contracting Office 2 Bronx, New York 10468, United States · NAICS 236220 Veterans Integrated Service Network 2 Service-Disabled Veteran-Owned Small Business