PA056 lancaster usarc HVAC

Closed Solicitation Posted

Solicitation number
W912BU-24-R-0032
Agency
ENDIST Philadelphia US Army Corps of Engineers, Department of Defense
Responses due
Set-aside
Competitive 8(a)

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
Z2AA Repair Or Alteration Of Office Buildings
Place of performance
Lancaster, Pennsylvania 17602, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The U.S. Army Corps of Engineers, Philadelphia District is seeking a single 8(a) small business contractor to design and construct a new HVAC system, associated power distribution circuits, and suspended ceiling systems at the Lancaster USARC Training Building in Lancaster, PA. The work includes removing portions of the existing HVAC, power, and ceiling systems, and providing temporary heating and cooling during construction. Proposals will be evaluated on past performance, technical approach, and price. Proposals are due by June 24, 2024.

This is a competitive 8(a) set-aside contract. The contract is for a firm-fixed price design-build project with a 365-calendar day period of performance. The solicitation provides as-built drawings and site photos for reference, and requires the contractor to complete an energy model and incorporate any energy efficiency betterments supported by a life-cycle cost analysis. The estimated contract value is not provided, but the NAICS code is 238220 - Plumbing, Heating, and Air-Conditioning Contractors, and the PSC is Z2AA-P - Repair Or Alteration Of Office Buildings.

Notice text

2 versions

Update #2 · Latest ·

The Lancaster USARC is located at 1135 Ranck Mill RD, Lancaster, PA 17602 and consists of two buildings which are the USARC Training Building and the Organizational Maintenance Shop (OMS). Work under this contract shall occur at the Training Building. Design and construct a HVAC system, associated power distribution circuits, and suspended ceiling systems at the Training
Building. Remove the portions indicated of the existing HVAC system, associated power distribution circuits, and the suspended ceiling system. Provide temporary heating and cooling when one, both, or the other are unavailable due to construction activities.
Complete an energy model, based on the final design, to report energy reductions in accordance with the applicable criteria. Proposals that offer betterments that impact energy efficiency must be supported by a life-cycle cost analysis.

Design and construction includes, but is not limited to, the following equipment: split Direct Expansion (DX) variable air volume air handling units; condensing units; piping; ductwork; insulation; Variable Air Volume (VAV) boxes; hydronic terminal units; Direct Digital Control (DDC) system; conduit; conductors; overcurrent protection; safety disconnect switches; acoustical ceiling tiles; and suspended ceiling grid system. See Parts 4, 5, and 6 for technical requirements.


See Appendix D for as-built drawings and Appendix E for site photographs. These are provided for information only and shall be field verified after award. As-builts are available upon request after award in Adobe PDF format. Provide as-built drawings in accordance with Section 01 78 00.

See Appendix C for demolition and new work drawings (which include a suggested zoning plan). Appendix F provides a control system design guide which shall be followed to complete the design.

EDIT: 17 June 2024- AMENDMENTS 0002 AND 0003 TO THE SOLICATION WERE ADDED TO SAM.GOV.

Update #1 ·

The Lancaster USARC is located at 1135 Ranck Mill RD, Lancaster, PA 17602 and consists of two buildings which are the USARC Training Building and the Organizational Maintenance Shop (OMS). Work under this contract shall occur at the Training Building. Design and construct a HVAC system, associated power distribution circuits, and suspended ceiling systems at the Training
Building. Remove the portions indicated of the existing HVAC system, associated power distribution circuits, and the suspended ceiling system. Provide temporary heating and cooling when one, both, or the other are unavailable due to construction activities.
Complete an energy model, based on the final design, to report energy reductions in accordance with the applicable criteria. Proposals that offer betterments that impact energy efficiency must be supported by a life-cycle cost analysis.

Design and construction includes, but is not limited to, the following equipment: split Direct Expansion (DX) variable air volume air handling units; condensing units; piping; ductwork; insulation; Variable Air Volume (VAV) boxes; hydronic terminal units; Direct Digital Control (DDC) system; conduit; conductors; overcurrent protection; safety disconnect switches; acoustical ceiling tiles; and suspended ceiling grid system. See Parts 4, 5, and 6 for technical requirements.


See Appendix D for as-built drawings and Appendix E for site photographs. These are provided for information only and shall be field verified after award. As-builts are available upon request after award in Adobe PDF format. Provide as-built drawings in accordance with Section 01 78 00.

See Appendix C for demolition and new work drawings (which include a suggested zoning plan). Appendix F provides a control system design guide which shall be followed to complete the design.

Attachments

Show all 12

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted