About this opportunity

The Department of the Navy Naval Facilities Engineering Command is soliciting proposals to replace two rooftop air handling units and related incidental work at Building 87, Marine Corps Air Station Cherry Point, North Carolina. The project requires the installation of large-capacity self-contained heat pumps exceeding 65,000 Btu/h, equipped with specifications including fully modulating economizers, low ambient control, MERV 13 filters, microprocessor controls with BACnet system interface, and variable speed motors. Key contract requirements mandate comprehensive documentation, performance testing, system performance reports, staff training, and compliance with ASHRAE, UL, and NFPA standards. The government will evaluate proposals based on lowest price. The amended proposal due date is January 6, 2026 at 12:00 PM local time, with a mandatory site visit scheduled for December 2, 2025, and contractors must complete all work within 210 calendar days after contract award.

This procurement is designated as a Total Small Business set-aside and is limited exclusively to three pre-selected Multiple Award Construction Contract (MACC) holders: Mechworks Mechanical Contractors, North State Mechanical, and R&W Construction Company. The estimated contract value ranges between $1,000,000 and $5,000,000, with the work classified under NAICS Code 238220 for Plumbing, Heating, and Air-Conditioning Contractors. The project involves replacing two existing cooling-only rooftop units (RTU-1 and RTU-2) with new equipment featuring cooling capacities of 492,200 Btu/h and 612,900 Btu/h respectively, using R-454B refrigerant and incorporating variable frequency drives with 20 horsepower motors. The work will be performed at MCAS Cherry Point, NC 28533, and must comply with specific installation requirements including maintaining a minimum 10-foot distance from the roof edge and proper integration with the existing Johnson Controls Metasys control system.

Notice text

The work includes replacing 2 rootop air handling units and incidental related work. Only the MACC holders listed on the first page of the solicitation may submit a proposal for this project. See attached RFP for addtional information.

Files

File Type Posted
Amendment 0001 7241766.pdf PDF
7242175 SpecsAsOne.pdf PDF
7241766 RFP.pdf PDF
7242175 DrawingsAsOne.pdf PDF

Notice history

Notice Type Posted
N400857241766 Replace Rooftop Units Building 87 Award Award Notice
This notice Latest solicitation Solicitation
Replace Rooftop Units Building 87 Original Pre-Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
Replace HVAC Rooftop Units at Building 2275 March Air Reserve Base, California 92518, United States · NAICS 238220 Army National Guard No set-aside
HVAC Replacement, Bldg. 2821 NAICS 238220 Air Combat Command Total Small Business
4120--rental of two chillers for one year Asheville, North Carolina 28805, United States · NAICS 238220 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
Compressor unit, REF, in repair/modification of NAICS 333415 Naval Supply Systems Command No set-aside
Repair Naval Reserve Training Facility B3370 Charleston AFB, South Carolina 29404, United States · NAICS 236220 Air Mobility Command Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity