N400857241766 Replace Rooftop Units Building 87
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- N400857241766
- Agency
-
Naval Facilities Engineering Command
Department of the Navy, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- PSC
- 5680 Miscellaneous Construction Materials
- Place of performance
- Cherry Point, North Carolina 28533, United States
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Navy Naval Facilities Engineering Command is soliciting proposals to replace two rooftop air handling units and related incidental work at Building 87, Marine Corps Air Station Cherry Point, North Carolina. The project requires the installation of large-capacity self-contained heat pumps exceeding 65,000 Btu/h, equipped with specifications including fully modulating economizers, low ambient control, MERV 13 filters, microprocessor controls with BACnet system interface, and variable speed motors. Key contract requirements mandate comprehensive documentation, performance testing, system performance reports, staff training, and compliance with ASHRAE, UL, and NFPA standards. The government will evaluate proposals based on lowest price. The amended proposal due date is January 6, 2026 at 12:00 PM local time, with a mandatory site visit scheduled for December 2, 2025, and contractors must complete all work within 210 calendar days after contract award.
This procurement is designated as a Total Small Business set-aside and is limited exclusively to three pre-selected Multiple Award Construction Contract (MACC) holders: Mechworks Mechanical Contractors, North State Mechanical, and R&W Construction Company. The estimated contract value ranges between $1,000,000 and $5,000,000, with the work classified under NAICS Code 238220 for Plumbing, Heating, and Air-Conditioning Contractors. The project involves replacing two existing cooling-only rooftop units (RTU-1 and RTU-2) with new equipment featuring cooling capacities of 492,200 Btu/h and 612,900 Btu/h respectively, using R-454B refrigerant and incorporating variable frequency drives with 20 horsepower motors. The work will be performed at MCAS Cherry Point, NC 28533, and must comply with specific installation requirements including maintaining a minimum 10-foot distance from the roof edge and proper integration with the existing Johnson Controls Metasys control system.
Notice text
The work includes replacing 2 rootop air handling units and incidental related work. Only the MACC holders listed on the first page of the solicitation may submit a proposal for this project. See attached RFP for addtional information.
Files
| File | Type | Posted |
|---|---|---|
| Amendment 0001 7241766.pdf | ||
| 7242175 SpecsAsOne.pdf | ||
| 7241766 RFP.pdf | ||
| 7242175 DrawingsAsOne.pdf |
Notice history
| Notice | Type | Posted |
|---|---|---|
| N400857241766 Replace Rooftop Units Building 87 | Award Notice | |
| This notice | Solicitation | |
| Replace Rooftop Units Building 87 | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Replace HVAC Rooftop Units at Building 2275 | Army National Guard | No set-aside | |
| HVAC Replacement, Bldg. 2821 | Air Combat Command | Total Small Business | |
| 4120--rental of two chillers for one year | Veterans Integrated Service Network 6 | Service-Disabled Veteran-Owned Small Business | |
| Compressor unit, REF, in repair/modification of | Naval Supply Systems Command | No set-aside | |
| Repair Naval Reserve Training Facility B3370 | Air Mobility Command | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity