The Department of the Navy's Naval Facilities Engineering Command is seeking a contractor to repair Boilers 3 and 4 burners at the Joint Expeditionary Base Little Creek - Fort Story steam plant in Virginia. The primary objectives include increasing boiler steam production capacity, addressing current limitations of approximately 70% and 35% design steam capacity, and performing comprehensive boiler inspections and air flow modeling. Contractors must perform detailed inspections, generate computer air flow models, and make precise adjustments to burner systems, with key deliverables including inspection findings and documentation of corrective actions. The solicitation (N4008525R2659) requires contractors to log in to https://piee.eb.mil to obtain full details, with proposals due by May 20, 2025. A mandatory site visit was scheduled for May 13, 2025, and pre-proposal inquiries were due by May 16, 2025, with the government evaluating responses based on technical capabilities and compliance with solicitation requirements.

The contract is not set aside for any specific small business category and will be awarded as a firm-fixed price task order. The estimated project value ranges between $250,000 and $500,000, with a 180-calendar day completion timeline. The project involves repairing two Nebraska-manufactured boiler models (NS-E-58) built in 2004, each with a rated steam capacity of 60,000 LB/HR and a maximum allowable working pressure of 250 Psig. Performance will occur at Fort Story, VA 23459, with specific requirements to ensure only one boiler is removed from service at a time and work is coordinated with steam plant staff. The solicitation falls under NAICS category 238220 for Plumbing, Heating, and Air-Conditioning Contractors and PSC category Z2JZ for Repair or Alteration of Miscellaneous Buildings, targeting contractors with specialized mechanical and utility infrastructure repair expertise.

Notice text

Login at https://piee.eb.mil and search for 'N4008525R2659' to obtain more details.*

Files

Show all 13

Notice history

Notice Type Posted
LC-777-Steam Plant-Repair Boilers 3 and 4 Burners, JEB Little Creek - Fort Story Base, Little Creek Site Latest Award Notice
LC-777-Steam Plant-Repair Boilers 3 and 4 Burners Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
16292 Steam Boiler Replacement Hill AFB, Utah 84056, United States · NAICS 238220 Air Force Sustainment Center Total Small Business
J045--FY27 Boilers Maintenance & Testing Department of Veterans Affairs VA Caribbean Healthcare System San Juan, Puerto Rico 00921, United States · NAICS 238220 Veterans Integrated Service Network 8 Service-Disabled Veteran-Owned Small Business
Replace radiant heating system and exhaust fan, bldg. 362 DAM neck annex, virginia beach, VA 23460 · NAICS 236220 Naval Facilities Engineering Command Total Small Business
USCG Station Eaton's Neck Boiler Combustion Analysis and calibration Northport, New York 11768, United States · NAICS 238220 — Total Small Business

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors