J045--Annual Boiler Maintenance RMR VAMC

Open Pre-Solicitation Posted

Solicitation number
36C25927Q0063
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Department of Veterans Affairs Rocky Mountain Regional Vamc Aurora CO 80045, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs, Veterans Health Administration, Network Contracting Office 19 (NCO 19) is conducting market research through a sources sought notice for annual boiler maintenance at the Rocky Mountain Regional VA Medical Center, with responses due December 4, 2026. No set-aside is used. The notice is for planning only, does not constitute a solicitation, and responses are not offers. Work is performed at the medical center in Aurora, Colorado, on four Cleaver Brooks boilers (Models 4WI-200-700-200ST), one de-aerator tank, one condensate/surge tank, and associated burner controls and instrumentation. Required services include annual internal and external boiler inspections, semi-annual combustion analysis and tuning, semi-annual safety device testing and pressure relief valve certification, oxygen sensor verification or replacement, six-year magnetic particle testing of the de-aerator tank, and H Stamp welding, testing, and certification as needed. Technicians must have one year of trade school, five years of institutional or industrial boiler plant experience, and Cleaver Brooks factory training. Contractors must demonstrate familiarity with NBIC Part 2, ASME Boiler and Pressure Vessel Code Sections VI and VII, VHA Directive 1810, NFPA 85, NFPA 70E, and the VHA Boiler Plant Safety Device Testing Manual. The contract period is one base year plus four option years. Work occurs Monday through Friday, 7:30 a.m. to 4:00 p.m., with two weeks' advance scheduling notice. Repair work is capped at contracted amounts per line item per year, and emergency call-back service is capped at $20,000 annually. Responses must include a capabilities and qualifications statement, an overview of proposed solutions, product descriptions aligned to the attached draft Statement of Work and Salient Characteristics List, and the completed market research table questionnaire. Failure to provide this information results in the assumption that the entire requirement cannot be met.

Notice text

Sources Sought Notice

Sources Sought Notice

Page 6 of 6

Sources Sought Notice

*= Required Field

Sources Sought Notice

Page 1 of 6

Sources Sought Notice Boiler Maintenance

Disclaimer:

This Request for Information (RFI) is issued solely for market research information and planning purposes and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. Responses to this notice are NOT offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.

Information Requested from Industry:

In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses in accordance with the attached Statement of Work draft / Salient Characteristics List.

Responses to market research table questionnaire shall be submitted. If this information is not provided, then it will be assumed the entire requirement cannot be met.

Description of Requirement:

The Department of Veterans Affairs, Veterans Health Administration (VHA), Network Contracting Office 19 (NCO 19) is conducting a market survey and is seeking potential sources for Boiler Maintenance at the Rocky Mountain Regional VA Medical Center. This Sources Sought Notice is issued for information and planning purposes only. This is not a solicitation or a request for proposal and shall not be construed as an obligation or commitment by the Government. An award will not be made on any offer submitted in response to this notice, and it shall not be implied that the Government is committed to providing any solicitation or award following this notice. The Government will not pay for any information received in response to this request, nor will the Government compensate a respondent for any costs incurred in developing the information provided.

Requirement Services:

Item No.

Item Description

0001

Annual Boiler Maintenance (Base +4 Option Years)

0002

Unscheduled Maintenance and Parts (Base +4 Option Years)

See attached statement of work

In response to this announcement, please provide the information requested below requested in this market research table questionnaire. If this information is not provided, then it will be assumed the entire requirement cannot be met:

NAICS Code:

Company Name:

Address:

UEI (Unique Entity ID) Number:

Contact Name:

Phone No.:

Email:

Business Size Information - Select all that applies:

Small Business

Emerging Small Business

Small Disadvantaged Business

Certified under Section 8(a) of the Small Business Act

HUBZone

Woman Owned

Certified Service-Disabled Veteran Owned Small

Veteran Owned Small Business

Large Business

FSS/GSA Contract Holder:

Yes No

FSS/GSA Contract Number:

Effective Date/ Expiration Date:

Proposed solution is listed and available on the above FSS/GSA Contract:

Yes No

Available pricing structure of proposed solution (select all that are applicable below, or remove to fit your requirement):

Pricing Model

Please Indicate Availability Below: (Yes / No / NA)

All on FSS

Open Market only

Mix of FSS & Open Market

Firm-Fixed Price

Federal Acquisition Regulation (FAR) Market Rearch Questions:

Buy American Act RFO 52.225-1 and RFO 52.225-2 Buy American Certificate What percentage of the proposed product (including leases and rentals) is a:

Domestic end product? _____________ (%)

Foreign end product? _______________ (%) Country of Origin:

Questions for Small Businesses ONLY:

Limitations on Subcontracting RFO 52.219-14

What percentage of the work would be subcontracted to another company? ________

What is the business size of the subcontractor?______

Per RFO 52.219-14 the following conditions must be met:

Services (except construction), it will not pay more than 50 percent of the amount paid by the Government for contract performance to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both services and supplies, the 50 percent limitation shall apply only to the service portion of the contract;

Supplies (other than procurement from a nonmanufacturer of such supplies), it will not pay more than 50 percent of the amount paid by the Government for contract performance, excluding the cost of materials, to subcontractors that are not similarly situated entities. Any work that a similarly situated entity further subcontracts will count towards the prime contractor's 50 percent subcontract amount that cannot be exceeded. When a contract includes both supplies and services, the 50 percent limitation shall apply only to the supply portion of the contract;

If subcontracting, what added value do you offer (RFO 52.215-23):

Nonmanufacturer Rule (RFO 52.219-33):

Does your company manufacturer these proposed items? [Â ] yes [Â ] no

Does your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: _________

Does your company primarily engaged in the retail or wholesale trade and normally sells the type of item being supplied? [Â ] yes [Â ] no

Does your company take ownership or possession of the item(s) with its personnel, equipment or facilities in a manner consistent with industry practice? [Â ] yes [Â ] no

Does your company supply the end item of a small business manufacturer, processor or producer made in the United States, or obtains a waiver of such requirement pursuant to paragraph (b)(5) CFR 121.406. [Â ] yes [Â ] no If yes, what is the manufacturer s name? ________________

Response Instructions:

Do not provide more than 8 pages, including cover letter page.

Submit your response via email to Christopher.Hollingsworth2@va.gov

Submit your response NLT 4:00pm (ET) on Friday, December 4, 2026;

Mark your response as Proprietary Information if the information is considered business sensitive.

VA has identified the appropriate North American Industry Classification System (NAICS) Code as 238220 Plumbing, Heating, and Air-Conditioning Contractors with a Small Business size of $19.0 Million or less. Please identify and explain any NAICS codes your company believes would better represent the predominant work included in the attached Statement of Work draft / Salient Characteristics List.

(End of Sources Sought)

Files

File Type Posted
Draft SOW_Annual Boiler Maint.doc DOC document
36C25927Q0063.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
H945--Boiler Controls Inspection and Testing NAICS 541350 Veterans Integrated Service Network 10 No set-aside
Radiant Heating Panel Replacement Aurora, Colorado 80045, United States · NAICS 238220 Veterans Integrated Service Network 19 Total Small Business
J041--Building 2 Steam Station Replacement West Haven Vamc West Haven CT 06516 · NAICS 238220 Veterans Integrated Service Network 1 Service-Disabled Veteran-Owned Small Business
Water Treatment Services Los Angeles, California 90073, United States · NAICS 238220 Veterans Integrated Service Network 22 Service-Disabled Veteran-Owned Small Business
J041--Service - AHU PM & Filter Evaluation - NWI Department of Veterans Affairs Nwi Va Medical Center Omaha NE 68105, United States · NAICS 238220 Veterans Integrated Service Network 23 No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors