Kennel Building Construction
Closed Solicitation Posted
This opportunity was awarded. See the award notice from .
- Solicitation number
- 12639526Q0088
- Agency
-
Marketing and Regulatory Programs Business Services
Animal and Plant Health Inspection Service, Department of Agriculture
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 236220 Commercial and Institutional Building Construction
- Place of performance
- Millville, Utah 84326, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The USDA Animal and Plant Health Inspection Service seeks construction of a pre-engineered metal kennel building at its Wildlife Services Predator Research Facility, with proposals due May 8, 2026. The procurement is a Total Small Business set-aside, restricting competition to small business concerns.
The facility will be approximately 3,400 square feet at 4200 S. 600 E. Cache County Road, Millville, Utah 84326, containing two kennel areas, a mud room, and a mechanical room per final design documents from A&E firm Cushing Terrell. Design drawings reflect 100% completion dated September 29, 2025, incorporating concrete foundations with radiant floor heating, eight-inch concrete masonry unit walls, metal roof systems with translucent panels, a 285 MBH condensing boiler serving radiant heating circuits, complete mechanical and plumbing systems, and LED lighting with occupancy sensors. Federal construction wage rates for Cache County, Utah apply per Davis-Bacon Act requirements, including rates for carpenters, electricians, plumbers, sheet metal workers, and laborers. Geotechnical conditions support a net bearing pressure of 2,500 pounds per square foot on natural soils with 30-inch minimum frost protection embedment; loose surficial soils to 4–5 inches must be removed from building footprint and exterior areas.
Contractors must submit separate pricing for Phase 1 (fencing, sitework, underground utilities, foundation, and floor slabs) and Phase 2 (masonry, structural steel, roofing, mechanical, plumbing, and electrical work), with Phase 2 as an add-alternate. Work must commence within 10 calendar days of the Notice to Proceed and be completed within 365 days. Evaluation uses a highest technically rated with fair and reasonable price approach, weighting price reasonableness and realism, technical capability including relevant pre-engineered metal building experience and detailed work sequencing, and past performance on customer satisfaction, regulatory compliance, schedule adherence, and specification conformance. Quotes must include itemized price breakdowns, relevant experience documentation, and past performance references with contract numbers, project titles, locations, award and completion dates, and contact information. Amendment 3, effective May 8, 2026, incorporated a price schedule. Mandatory site visit was April 15, 2026; questions were due April 24, 2026. NAICS 236220, PSC Y1JZ.
Notice text
9 versions
Update #9 · Latest ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Amendment 1 is posted below.
Site visit attendance sheet is posted below.
RFIs and responses posted below.
A second amendment is posted below.
More RFIs and responses posted below.
Amendment 3 is posted below, extending the closing time to 2 p.m. CT today and incorporating a price schedule.
Update #8 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Amendment 1 is posted below.
Site visit attendance sheet is posted below.
RFIs and responses posted below.
A second amendment is posted below.
More RFIs and responses posted below.
Update #7 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Amendment 1 is posted below.
Site visit attendance sheet is posted below.
RFIs and responses posted below.
A second amendment is posted below.
Update #6 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Amendment 1 is posted below.
Site visit attendance sheet is posted below.
RFIs and responses posted below.
Update #5 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Amendment 1 is posted below.
Site visit attendance sheet is posted below.
Update #4 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Amendment 1 is posted below.
Update #3 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
RFIs:
- Roof Metal Panel
Sheet No. A110 identifies the roof panel type as PBU; however, Specification Section 074113.16 calls for a standing seam roof panel. Please confirm which roof panel type is to be considered correct. Metal Roof Panel is to be PBU. - Roof Gauge
Kindly confirm the required gauge for both the roof and soffit panels. Roof panel and soffits to be 24 gauge.
Update #2 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
NOTE: SEND ALL QUERIES, TECHNICAL AND OTHERWISE, TO THE POC NAMED BELOW.
A geotech report is posted below.
Update #1 ·
USDA-APHIS-Wildlife Services needs construction of a new kennel building per the final design documents developed by the A&E firm Cushing Terrell. The structure will be a pre-engineered metal building of approximately 3,400SF, containing four sections: kennel areas A & B, mud room and mechanical room. The Predator Research Facility’s mission is to generate and disseminate ecological information related to carnivore management, particularly aimed at reducing conflicts with livestock, humans, and native prey species.
Solicitation and construction documents are posted below.
Files
| File | Type | Posted |
|---|---|---|
| 12639526Q0088-0003.pdf | ||
| RFIs and Responses 2.docx | DOCX document | |
| 12639526Q0088-0002.pdf | ||
| RFIs and Responses.docx | DOCX document | |
| Site visit attendance.pdf | ||
| 12639526Q0088-0001.pdf | ||
| Geotech report.pdf | ||
| 12639526Q0088.docx | DOCX document | |
| Attachment 4_Kennel Drawings.pdf | ||
| Attachment 3_Kennel Project Manual 02162026.pdf | ||
| Attachment 2_Federal Construction Wage Rates_Cache County.txt | TXT text file | |
| Attachment 1_SOW for Utah Kennel Building Mar 2026.doc | DOC document |
Show all 12
Notice history
| Notice | Type | Posted |
|---|---|---|
| Kennel Building Construction | Award Notice | |
| This notice | Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| GAOA Kents Lk. CG Reconstruction, Fishlake NF, Utah | Forest Service | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity