J045--Annual Boiler Safety Testing and Repair Services
Closed Solicitation Posted
This opportunity was awarded. See its 2 award notices in the notice history.
- Solicitation number
- 36C25624Q0417
- Agency
-
Veterans Integrated Service Network 16
Veterans Health Administration, Department of Veterans Affairs
- Responses due
- Set-aside
- Service-Disabled Veteran-Owned Small Business
Opportunity facts
- NAICS code
- 238220 Plumbing, Heating, and Air-Conditioning Contractors
- Place of performance
- Fayetteville, Arkansas 72703, United States
Notice details come from SAM.gov. Updated .
About this opportunity
This solicitation seeks a contractor to provide annual boiler safety testing and repair services for the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 16. The contractor must inspect, test, document, and potentially repair high and low pressure boiler safety devices located at the Veterans Health Care System of the Ozarks facility in Fayetteville, Arkansas. The evaluation criteria will consider price, technical approach, and past performance. The deadline for questions is March 20, 2024, and offers are due by the same date.
The solicitation is set aside for service-disabled veteran-owned small businesses. The predominate NAICS code is 238220 and the PSC code is R499. The place of performance is Fayetteville, Arkansas. Services will be provided over a one-year base period and four one-year options, with inspections required annually each March. Emergency phone support must be available within one hour and on-site emergency work may be ordered through contract modifications.
Notice text
6 versions
Update #6 · Latest ·
*****************************************************************************************************************************************************
03/13/24: Amendment 005 has been issued to address questions and answers to the solicitation. See 36C25624Q0417 Amendment 004 for further details.
*****************************************************************************************************************************************************
03/11/24: Amendment 004 has been issued to address questions and answers to the solicitation. See 36C25624Q0417 Amendment 004 for further details.
*****************************************************************************************************************************************************
03/05/24: Amendment 003 has been issued to address questions and answers to the solicitation. See 36C25624Q0417 Amendment 003 for further details.
*****************************************************************************************************************************************************
03/04/24: Amendment 002 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 002 for further details.
*****************************************************************************************************************************************************
02/22/24: Amendment 001 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 001 for further details. *****************************************************************************************************************************************************Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, consumables, parts, and related services, in accordance with the SOW to inspect, test, document, and at Contracting Officers Representative (COR) discretion, may repair high pressure and low pressure boiler safety devices located on the VHSO Veterans Affairs (VA) station, 1100 N. College Avenue, Fayetteville, AR 72703.VHSO will have the boilers that are to be serviced, prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale: fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation; boiler steam flow, stack temperature and flue gas oxygen instruments operating.
Update #5 ·
*****************************************************************************************************************************************************
03/11/24: Amendment 004 has been issued to address questions and answers to the solicitation. See 36C25624Q0417 Amendment 004 for further details.
*****************************************************************************************************************************************************
03/05/24: Amendment 003 has been issued to address questions and answers to the solicitation. See 36C25624Q0417 Amendment 003 for further details.
*****************************************************************************************************************************************************
03/04/24: Amendment 002 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 002 for further details.
*****************************************************************************************************************************************************
02/22/24: Amendment 001 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 001 for further details. *****************************************************************************************************************************************************Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, consumables, parts, and related services, in accordance with the SOW to inspect, test, document, and at Contracting Officers Representative (COR) discretion, may repair high pressure and low pressure boiler safety devices located on the VHSO Veterans Affairs (VA) station, 1100 N. College Avenue, Fayetteville, AR 72703.VHSO will have the boilers that are to be serviced, prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale: fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation; boiler steam flow, stack temperature and flue gas oxygen instruments operating.
Update #4 ·
*****************************************************************************************************************************************************
03/05/24: Amendment 003 has been issued to address questions and answers to the solicitation. See 36C25624Q0417 Amendment 003 for further details.
*****************************************************************************************************************************************************
03/04/24: Amendment 002 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 002 for further details.
*****************************************************************************************************************************************************
02/22/24: Amendment 001 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 001 for further details. *****************************************************************************************************************************************************Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, consumables, parts, and related services, in accordance with the SOW to inspect, test, document, and at Contracting Officers Representative (COR) discretion, may repair high pressure and low pressure boiler safety devices located on the VHSO Veterans Affairs (VA) station, 1100 N. College Avenue, Fayetteville, AR 72703.VHSO will have the boilers that are to be serviced, prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale: fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation; boiler steam flow, stack temperature and flue gas oxygen instruments operating.
Update #3 ·
*****************************************************************************************************************************************************
03/04/24: Amendment 002 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 002 for further datils.
*****************************************************************************************************************************************************
02/22/24: Amendment 001 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 001 for further details. *****************************************************************************************************************************************************Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, consumables, parts, and related services, in accordance with the SOW to inspect, test, document, and at Contracting Officers Representative (COR) discretion, may repair high pressure and low pressure boiler safety devices located on the VHSO Veterans Affairs (VA) station, 1100 N. College Avenue, Fayetteville, AR 72703.VHSO will have the boilers that are to be serviced, prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale: fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation; boiler steam flow, stack temperature and flue gas oxygen instruments operating.
Update #2 ·
*****************************************************************************************************************************************************02/22/24: Amendment 001 has been issued to address questions, answers, and changes made to the solicitation. See 36C25624Q0417 Amendment 001 for further details. *****************************************************************************************************************************************************Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, consumables, parts, and related services, in accordance with the SOW to inspect, test, document, and at Contracting Officers Representative (COR) discretion, may repair high pressure and low pressure boiler safety devices located on the VHSO Veterans Affairs (VA) station, 1100 N. College Avenue, Fayetteville, AR 72703.VHSO will have the boilers that are to be serviced, prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale: fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation; boiler steam flow, stack temperature and flue gas oxygen instruments operating.
Update #1 ·
Contractor must furnish all management, supervision, labor, material, equipment, tools, supplies, consumables, parts, and related services, in accordance with the SOW to inspect, test, document, and at Contracting Officers Representative (COR) discretion, may repair high pressure and low pressure boiler safety devices located on the VHSO Veterans Affairs (VA) station, 1100 N. College Avenue, Fayetteville, AR 72703.VHSO will have the boilers that are to be serviced, prepared for the technicians upon their scheduled arrival. This includes having the boilers clean of soot and loose scale: fully warmed and at normal steam pressure; steam exhaust silencer system operable; all boiler, burner and fuel train pressure gages and thermometers calibrated; fuel meters in accurate operation; boiler steam flow, stack temperature and flue gas oxygen instruments operating.
See attachments for further details.
Files
Show all 18
Notice history
| Notice | Type | Posted |
|---|---|---|
| J045--Annual Boiler Safety Testing and Repair Services | Award Notice | |
| J045--Annual Boiler Safety Testing and Repair Service Contract | Award Notice | |
| This notice | Solicitation | |
| J045--Annual Boiler Safety Testing and Repair Services | Pre-Solicitation |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| White City, Oregon, Boiler Inspection Services Solicitation Base Year + Four Option Years (offers are now due on 11/13/2026) | Veterans Integrated Service Network 20 | Service-Disabled Veteran-Owned Small Business | |
| N048-- B41 Isolation Valve Installation | Veterans Integrated Service Network 16 | Service-Disabled Veteran-Owned Small Business | |
| H945--Boiler Controls Inspection and Testing | Veterans Integrated Service Network 10 | Service-Disabled Veteran-Owned Small Business | |
| 657-27-107JC, Replace Select Hot Water Heating System | Veterans Integrated Service Network 15 | Service-Disabled Veteran-Owned Small Business Sole Source | |
| J012--Fire Suppression Testing | Veterans Integrated Service Network 8 | Service-Disabled Veteran-Owned Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity