Fire Monitoring, Inspections, Maintenance, and Remediation Services
Open Pre-Solicitation Posted
- Solicitation number
- IHSSS11182026
- Agency
-
Indian Health Service
Department of Health and Human Services
- Responses due
- Set-aside
- Indian Small Business Economic Enterprise
Opportunity facts
- NAICS code
- 561621 Security Systems Services (except Locksmiths)
- Place of performance
- Oklahoma City, Oklahoma 73179, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Indian Health Service is seeking to identify Indian Small Business Economic Enterprises (ISBEEs) for fire alarm monitoring, periodic inspections, corrective maintenance, and life-safety remediation services under the Indian Small Business Economic Enterprise set-aside, with responses due November 25, 2026. The procurement uses Buy Indian Act negotiation authority (25 U.S.C. 47) under 48 CFR 326.603-3 and IHM 5.5-6 to prefer Indian Economic Enterprises whenever use of that authority is authorized and practicable. Respondents must submit a capability statement of no more than 5 pages, plus the attached Buy Indian Act Indian Economic Enterprise Representation Form, by email to Contract Specialist Jarrod Prince at jarrod.prince@ihs.gov by 4:00 PM CST on November 25, 2026. The notice states that generic capability statements are insufficient and that responses must directly demonstrate capability, experience, and capacity.
Places of performance are Lawton Indian Hospital (Lawton, Oklahoma), Anadarko Indian Health Center (Anadarko, Oklahoma), and Carnegie Indian Health Center (Carnegie, Oklahoma). The attached Sources Sought document states that these facilities are operated by the Lawton Service Unit.
The attached document describes a 5-year Blanket Purchase Agreement requiring 24/7/365 UL-listed central station monitoring; compliance with NFPA codes including 10, 13, 25, 72, 80, 96, and 101; and continuous Joint Commission Environment of Care and Life Safety accreditation. Scope includes maintaining existing Notifier ONYX fire alarm systems, water-based suppression systems, fire pumps, and 25 fire/smoke barrier doors at Lawton Indian Hospital, plus monitoring and extinguisher services at Anadarko and Carnegie. Contractors must hold Oklahoma Department of Labor licenses for Commercial Fire Alarm, Fire Sprinkler, and Central Station Monitoring, maintain Notifier factory certification, furnish all tools, calibrated instruments, parts, and software, and respond within 2 hours to catastrophic failures. All personnel require HSPD-12 security verification, and HIPAA compliance and tobacco-free facility policies apply. Deliverables include itemized inspection reports within 5 business days.
The notice is NAICS 561621, Security Systems Services (except Locksmiths), with a $25.0 million size standard per the attached document, and PSC 6350.
Notice text
Pursuant to 48 CFR Part 326, Subpart 326.603-3 and IHM 5.5-6, the Indian Health Service (IHS) must use the negotiation authority of the Buy Indian Act, 25 U.S.C. 47, to give preference to Indian Economic Enterprises (IEE) whenever the use of that authority is authorized and practicable.
The Government is seeking to identify Indian Small Business Economic Enterprises (ISBEEs) capable of performing the below Indian Health Service (IHS) requirement for Fire Alarm Monitoring, Periodic Inspections, Corrective Maintenance, and Life-Safety Remediation Services. Any vendor responding to this notice should submit their capability statement as well as the Buy Indian Act Indian Economic Enterprise Representation Form (attached). Instructions for submission are outlined below.
Indian Small Business Economic Enterprises (ISBEEs) and other small business are highly encouraged to respond to this notice. However, firms should understand that generic capability statements are not sufficient for effective evaluation of their capacity and capability to perform the work required. Responses must directly demonstrate the company's capability, experience, and ability to provide uninterrupted fire detection, 24/7/365 central station monitoring, water-based fire suppression readiness, physical fire and smoke barrier containment, and emergency restoration capabilities are essential to safeguarding patients, healthcare personnel, and visitors. All life-safety systems must maintain continuous accreditation with The Joint Commission (TJC) Environment of Care and Life Safety standards, as well as strict compliance with applicable National Fire Protection Association (NFPA) codes, including the Life Safety Code (NFPA 101). The places of performance are: Lawton Indian Hospital, 1515 NE Lawrie Tatum Rd, Lawton, OK 73507; Anadarko Indian Health Center, 201 E Parker McKenzie Dr., Anadarko, OK 73005; Carnegie Indian Health Center, 212 E 4th St, Carnegie, OK 73015.
Applicable NAICS Code: 561621 — Security Systems Services (except Locksmiths) (small business size standard: $25.0 million). Product Service Code (PSC): 6350.
Files
| File | Type | Posted |
|---|---|---|
| SS.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| Full-service maintenance, inspection, calibration, and repair of a body plethysmograph system. | Indian Health Service | Indian Small Business Economic Enterprise | |
| IHSSS11132026_HVAC/Refrigeration Parts, Equipment & Refrigerant | Indian Health Service | Buy Indian | |
| HVAC Filters & Filtration Media | Indian Health Service | Buy Indian | |
| ISBEE/IEE: RPMS EHR ONC Certified Health IT: Certification/Consultation | Indian Health Service | Indian Small Business Economic Enterprise | |
| Fire Door Inspection, Assessment, and Maintenance at the Albuquerque Area IHS Healthcare Facilities | Indian Health Service | Total Small Business |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity