Full-service maintenance, inspection, calibration, and repair of a body plethysmograph system.
Open Pre-Solicitation Posted
- Solicitation number
- IHS1532611
- Agency
-
Indian Health Service
Department of Health and Human Services
- Responses due
- Set-aside
- Indian Small Business Economic Enterprise
Opportunity facts
- NAICS code
- 811210 Electronic and Precision Equipment Repair and Maintenance
- Place of performance
- Lawton, Oklahoma 73507, United States
- Points of contact
Notice details come from SAM.gov. Updated .
About this opportunity
The Indian Health Service is seeking capability statements from Indian Small Business Economic Enterprises (ISBEEs) under a Buy Indian Act sources sought notice for full-service maintenance, inspection, calibration, and repair of an MGC Diagnostics Platinum RTD Elite Series body plethysmograph system, with responses due November 23, 2026 at 3:00 PM CST. The Set Aside is Indian Small Business Economic Enterprise. The notice is not a solicitation for proposals, abstracts, or quotations and does not obligate the Government to award a contract. Other small businesses are encouraged to respond, but generic capability statements are insufficient, and responses must demonstrate direct capability and experience for this work.
Place of performance is the Respiratory Therapy Department at Lawton Indian Hospital, 1515 NE Lawrie Tatum Rd, Lawton, OK 73507. The period consists of a 12-month base year (December 1, 2026 through November 30, 2027) with four optional 12-month renewal years. NAICS is 811210 with a $34.0 million size standard, and PSC is J065.
Technicians must be factory-trained and certified by Medical Graphics Corporation. The contractor must provide one annual preventive maintenance visit with system recertification within 30 days of the annual anniversary date, respond to emergency repairs within 24 to 48 hours and non-critical repairs within 3 to 5 business days, supply 100% OEM replacement parts with a minimum one-year warranty, and deliver itemized Field Service Reports within ten calendar days of service completion. The contractor supplies all specialized diagnostic tools, medical-grade and NIST-traceable calibration gases, and testing equipment. The Government furnishes a climate-controlled work environment and reasonable equipment access. Toll-free technical phone and remote support must be available 6:00 AM to 8:00 PM CST, Monday through Friday, excluding federal holidays.
Submissions are capped at five pages and must include a capability statement and the Buy Indian Act Indian Economic Enterprise Representation Form. Required content covers company name, socioeconomic status, SAM UEI, points of contact, CAGE code, Tax ID, GSA Schedule number if applicable, and SAM registration status. Send responses to Contract Specialist Jarrod Prince at jarrod.prince@ihs.gov. Responses will not be returned, and no compensation will be provided.
Notice text
This is a Sources Sought notice. This is NOT a solicitation for proposals, proposal abstracts, or quotations.
Pursuant to 48 CFR Part 326, Subpart 326.603-3 and IHM 5.5-6, the Indian Health Service (IHS) must use the negotiation authority of the Buy Indian Act, 25 U.S.C. 47, to give preference to Indian Economic Enterprises (IEE) whenever the use of that authority is authorized and practicable.
The Government is seeking to identify Indian Small Business Economic Enterprises (ISBEEs) capable of performing the below Indian Health Service (IHS) requirement for Respiratory Therapy MGC Diagnostic Platinum RTD Elite Series Service Contract. Any vendor responding to this notice should submit their capability statement as well as the Buy Indian Act Indian Economic Enterprise Representation Form (attached). Instructions for submission are outlined below.
Indian Small Business Economic Enterprises (ISBEEs) and other small business are highly encouraged to respond to this notice. However, firms should understand that generic capability statements are not sufficient for effective evaluation of their capacity and capability to perform the work required. Responses must directly demonstrate the company's capability, experience, and ability to provide a full-service maintenance, inspection, calibration, and repair agreement for the Respiratory Therapy Department’s MGC Diagnostics Platinum Elite DL Series w/ Body Plethysmograph system. The place of performance is Lawton Indian Hospital, 1515 NE Lawrie Tatum Rd, Lawton, OK 73507. Applicable NAICS Code: 811210 — Maintenance (small business size standard: $34.0 million). Product Service Code (PSC): J065.
Files
| File | Type | Posted |
|---|---|---|
| IHS_Sources_Sought_IHS1532611_2026-11-16.26.pdf |
Similar open opportunities
| Opportunity | Agency | Set-aside | Responses due |
|---|---|---|---|
| IHSSS11132026_HVAC/Refrigeration Parts, Equipment & Refrigerant | Indian Health Service | Buy Indian | |
| HVAC Filters & Filtration Media | Indian Health Service | Buy Indian | |
| Vital Signs Monitoring and Physical Assessment Units | Indian Health Service | No set-aside | |
| PM Services on Sterilization Equipment | Indian Health Service | Indian Small Business Economic Enterprise | |
| Inscription House Health Center - Medical Gas Service | Indian Health Service | No set-aside |
On GovTribe
Work this opportunity
- Track it in your pipeline
- Find teaming partners
- Similar opportunities
- Ask GovTribe AI about this opportunity