Equipment Replacement - Replace Heating, Ventilati

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
140P5125Q0011
Agency
Southeast Region National Park Service, Department of the Interior
Responses due
Set-aside
Total Small Business

Opportunity facts

NAICS code
238220 Plumbing, Heating, and Air-Conditioning Contractors
PSC
N041 Installation Of Equipment- Refrigeration, Air Conditioning, And Air Circulating Equipment
Place of performance
1616 Chappie James Avenue Tuskegee, Alabama 36083, United States
Points of contact

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of the Interior's National Park Service Southeast Region is seeking a contractor to replace the outdated HVAC system at the Tuskegee Airmen National Historic Site in Tuskegee, Alabama. The solicitation (RFQ #140P5125Q0011) requires comprehensive replacement of the existing system, including a 7.5-ton heat pump split system, furnace, condenser, evaporator coil, thermostat, wiring, pipes, and ductwork. The procurement will be awarded using a Lowest Price Technically Acceptable (LPTA) source selection method, with evaluation criteria focusing on price, technical capability (acceptable/unacceptable), and past performance (pass/fail). Potential bidders must submit three volumes: technical capability, past performance, and pricing, with a site visit scheduled for March 27, 2025, at 9:00am CT. Questions from contractors must be submitted electronically to the Contracting Officer by 1:00pm ED on March 31, 2025, with quotes due by April 7, 2025, at 1:00 PM EST.

The contract is a 100% small business set-aside under NAICS code 238220, with a small business size standard of $19,000,000. The project will be performed at 1616 Chappie James Ave, Tuskegee, AL 36083, with a performance period from April 7 to June 6, 2025. While no specific incumbent or current contractor is mentioned, the solicitation requires detailed technical specifications, including installation of an American Standard system with specific model numbers (Condenser Model TWA09043AAAE02P, Air Handler model TWE09043AAAP01H) and an IEER rating of 12.4. The project allows for alternative refrigerants like R454B or R32 and requires a new 4" concrete pad, humidity measurement control, and a formal air balancing report. Work is limited to weekday hours of 7:00 am to 4:00 pm Monday through Friday, with an emphasis on preserving the historical site's integrity and minimizing disruption.

Notice text

2 versions

Update #2 · Latest ·

The purpose of this amendment is to provide a revised statement of work and questions and answers received in response to the solicitation.

The revised statement of work is provided as attachment 0006.

Questions and answers are provided as attachment 0007.

Update #1 ·

Replace the outdated HVAC System with a more energy efficient one. The contractor shall replace the furnace, condenser, evaporator coil, thermostat, any necessary wiring, pipes, duct work and balance the system for Tuskegee Airmen National Historic Site Tuskegee, Alabama.

Attachments

Notice history

Notices posted for this opportunity, newest first
Notice Type Posted
Equipment Replacement - Replace Heating, Ventilati Award Award Notice
Equipment Replacement - Replace Heating, Ventilati This notice · Latest solicitation Solicitation

On GovTribe

Work this opportunity on GovTribe

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity