Black hills HCS generator testing, repair, and maintenance services - unrestricted

Closed Solicitation Posted

This opportunity was awarded. See the award notice from .

Solicitation number
36C26326Q0767
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
South Dakota 57741, United States

Notice details come from SAM.gov. Updated .

About this opportunity

The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 23 seeks generator testing, repair, and maintenance services for the Black Hills Health Care System, with proposals due June 16. This is an unrestricted procurement with no set-aside.

Place of performance is Fort Meade and Hot Springs, South Dakota, and a VA clinic in Rapid City if mobile units are present. The scope covers 12 permanent generators ranging from 16.8 KW to 2000 KW across multiple buildings, plus three mobile generator units. The contractor must perform semi-annual preventive maintenance inspections, emergency repairs with four-hour callback response time, annual load bank testing per NFPA 110 standards (50 percent load for 30 minutes and 75 percent load for 1 hour), and semi-annual automatic transfer switch testing in bypass mode. Specific generators require 4-hour load bank tests every 36 months. The contractor provides all labor, supplies, filters, fluids, and parts; repairs exceeding $2,500 require Contracting Officer approval. Inspection reports must be submitted within 30 days of service completion, and fluid testing is conducted by third-party testers. Planned maintenance occurs Monday through Friday, 8:00 AM to 4:00 PM.

All on-site contractor personnel must complete VA privacy training (TMS 20939) and comply with HIPAA and NARA records management requirements. The NAICS code is 811210, Electronic and Precision Equipment Repair and Maintenance. The PSC code is J061, Maint/Repair/Rebuild Of Equipment—Electric Wire And Power Distribution Equipment. Amendment 0001 was issued June 10, 2026.

Notice text

THE VA BLACK HILLS HEALTH CARE SYSTEM REQUIRES GENERATOR TESTING, REPAIR, AND MAINTENANCE SERVICES. 

SEE ATTACHED SOLICITATION AND OTHER ATTACHED DOCUMENTS.  

Files

Notice history

Notice Type Posted
J061--BHH - Generator Testing & Maintenance - Interstate Power Systems - 568C60119 Award Award Notice
This notice Latest solicitation Solicitation

Similar open opportunities

Opportunity Agency Set-aside Responses due
J061--Generator Inspection Service and Routine Maintenance - NAICS 238210 Veterans Integrated Service Network 6 No set-aside
Request for Information (RFI) - CONUS Generator Maintenance Washington, District of Columbia, United States · NAICS 811310 Federal Emergency Management Agency Total Small Business
J061--SOURCES SOUGHT NOTICE - Triennial Electrical Inspection Testing and Maintenance Services Requirement - Louis A Johnson VA Medical Center 36C24527Q0039 Department of Veterans Affairs Louis A Johnson VA Medical Center Clarksburg, West Virginia 26301, United States · NAICS 238210 Veterans Integrated Service Network 5 No set-aside
Generator, variable, in repair/modification of NAICS 336413 Naval Supply Systems Command No set-aside
J061--Thompson Power Generator Service RFI Intent to Sole Source Department of Veterans Affairs Tennessee Valley Healthcare System Tvhs Murfreesboro, Tennessee 37129, United States · NAICS 333120 Veterans Integrated Service Network 9 Service-Disabled Veteran-Owned Small Business Sole Source

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity