H266--Sources Sought - Equipment Testing and Program Monitoring Services of Radiology and Quality Programs - VA Black Hills Health Care System

Open Pre-Solicitation Posted

Solicitation number
36C26327Q0137
Agency
Responses due
Set-aside
No set-aside

Opportunity facts

Place of performance
Va Black Hills Health Care System Fort Meade Va Medical Center Fort Meade Sd 57741

Notice details come from SAM.gov. Updated .

About this opportunity

The VA Black Hills Health Care System, part of VISN 23, is conducting sources sought market research for equipment testing and program monitoring services supporting its Radiology and Quality Programs, with responses due December 3, 2026, at 12:00 PM Central Time. This is market research only: no solicitation, proposals, final pricing, or contract award will result from it, and the notice lists no set-aside. The government will use responses to develop its acquisition strategy regarding possible set-asides for Service-Disabled Veteran-Owned, Veteran-Owned, and other socio-economic small business categories. Services would cover Fort Meade VA Medical Center (Fort Meade, South Dakota), Rapid City Community-Based Outpatient Clinic, and Hot Springs VA Medical Center. The requirement centers on a Board Certified diagnostic radiological physicist performing X-ray equipment testing, dose rate testing, performance monitoring, and leak testing of sealed radiation sources, in compliance with VHA National Health Physics Program guidelines and ACR Technical Standards. The equipment inventory includes radiographic-fluoroscopic systems, mobile C-arms, mobile MRI units, CT scanners, dental X-ray systems, dose calibrators, thyroid uptake systems, densitometers, and sealed sources (Cs-137, Ba-133, Co-57, Co-60). Testing cycles occur in April and October, with as-needed certification for newly acquired or repaired equipment. The contract period runs December 15, 2026, through December 14, 2027. Respondents must answer five mandatory questions covering socio-economic status and SAM Unique Entity ID, availability through existing government contracts, subcontracting plans, solution delivery lead time, and pricing across five line items, including travel up to $2,500 per instance for seven trips. No budget or dollar ceiling is stated. Responses go to Alisha Milander at Alisha.Milander@va.gov. The government will not pay for response costs. The NAICS code is 811210 with a $34.0 million size standard.

Notice text

Page 1 of 38

Page 14 of 39

Page 1 of 38

The VA Black Hills Health Care System Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations is conducting market research in accordance with RFO 17.204-1 Exercise of Options for Equipment Testing and Program Monitoring Services of the Radiology and Quality Programs as described in the Preliminary Statement of Work below.

This is a SOURCES SOUGHT NOTICE only looking for businesses to provide the services listed in the Preliminary Statement of Work below for market research purposes. No proposals are being requested or accepted with this notice. THIS IS NOT A SOLICITATION FOR PROPOSALS OR FINAL PRICING AND NO CONTRACT SHALL BE AWARDED FROM THIS NOTICE. This notice shall not be construed as a solicitation or as an obligation on the part of the Department of Veterans Affairs.

Responses to this notice will be treated only as information for the Government to consider as part of their market research efforts. The information provided will be used by the Government in developing its acquisition strategy regarding possible set aside for Service-Disabled Veteran-Owned, Veteran-Owned, and other socio-economic categories of small business. Interested parties are responsible for adequately marking proprietary, restricted or competition sensitive information contained in their response. The Government does not intend to pay for the information submitted in response to this notice and parties responding will not be entitled to payment for direct or indirect costs incurred in responding to this notice.

The North American Industry Classification System (NAICS) code for this requirement is 811210, Electronic and Precision Equipment Repair and Maintenance, with an SBA Small Business Size Standard of $34.0 Million.

If you are a vendor capable of providing the requested information and required services described below with competitive pricing, send your information with a description of proof of capability and answers to all questions to: Alisha.Milander@va.gov on or before Thursday, December 3, 2026 at 12:00 PM Central Time.

Please provide answers as appropriate to the following questions in the table below with your response to this Sources Sought. Failure to respond accurately to the following questions may affect the acquisition strategy. Failure to respond to the questions at all, or not respond to select individual questions, will result in your response being determined as non-responsive.

1.Â

Please provide all socio-economic categories of your firm (e.g., SDVOSB, VOSB, WOSB, Large Business, 8a, etc.) as well as your firm s SAM Unique Entity ID number (replaces DUNS number) and Government Contract POC.

2.Â

State whether the requested services may be ordered against a government contract awarded to your organization (e.g Federal Supply Schedule (FSS), General Services Administration (GSA), etc.).

3.Â

State if subcontracting is contemplated for this requirement and what percentage of the work will be subcontracted and for what tasks.

4.

Provide estimated lead time to deliver a fully functioning solution as described in the Preliminary Statement of Work below.

5.

Complete the ITEM INFORMATION directly below this section for market research pricing for the services described in the Preliminary Statement of Work.

ITEM INFORMATION

ITEM NUMBER

DESCRIPTION OF SUPPLIES/SERVICES

QUANTITY

UNIT

UNIT PRICE

AMOUNT

0001

1.00

JB

$___________

$___________

Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring on radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work.

Contract Period: Base

POP Begin: 12-15-2026

POP End: 12-14-2027

PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance

PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment

0002

1.00

JB

$___________

$___________

Perform leak testing of sealed sources for the Black Hills Health Care System during the month of April 2027 in accordance with the Statement of Work.

Contract Period: Base

POP Begin: 12-15-2026

POP End: 12-14-2027

PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance

PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment

0003

1.00

JB

$___________

$___________

Perform leak testing of sealed sources for the Black Hills Health Care System during the month of October 2027 in accordance with the Statement of Work.

Contract Period: Base

POP Begin: 12-15-2026

POP End: 12-14-2027

PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance

PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment

0004

5.00

JB

$___________

$___________

Perform certification via X-ray equipment testing, dose rate testing, and performance monitoring as requested on all newly acquired radiographic fluoroscopy X-ray equipment for the Black Hills Health Care System throughout the period of performance and also perform follow-up testing on existing equipment on an as-needed basis when repairs are made or equipment is changed out requiring re-testing in accordance with the Statement of Work.

Contract Period: Base

POP Begin: 12-15-2026

POP End: 12-14-2027

PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance

PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment

0005

7.00

EA

$___________

$___________

Travel Expenses to perform services in accordance with the Statement of Work. Not to exceed $2,500 per instance.

Contract Period: Base

POP Begin: 12-15-2026

POP End: 12-14-2027

PRINCIPAL NAICS CODE: 811210 - Electronic and Precision Equipment Repair and Maintenance

PRODUCT/SERVICE CODE: H266 - Equipment and Materials Testing - Instruments and Laboratory Equipment

PRELIMINARY STATEMENT OF WORK

Introduction

The Black Hills Health Care System, Facilities Management Department requires a Board Certified diagnostic radiological physicist to perform equipment testing and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. The Board Certified diagnostic radiological physicist shall have the capability to support and service ALL listed radiographic/fluoroscopic x-ray equipment and also provide certification as requested of all newly acquired radiographic/fluoroscopic x-ray equipment throughout the period of performance of the contract and all exercised option years.

Requirements

General:

The Contractor shall provide a Board Certified diagnostic radiological physicist to perform equipment testing as specified in Paragraph 2.b. for all necessary equipment in April of each year (see Paragraph 2.d. Equipment Listing) and program monitoring services of the radiology and quality programs at the Fort Meade VA Medical Center, Rapid City CBOC, and Hot Springs VA Medical Center locations. Services requested also include leak testing of sealed radiation sources as specified in Paragraph 2.c. in April and October of each year for specified equipment (see Paragraph 2.d. Equipment Listing). Additional services include follow-up testing and certification on existing equipment to be done on an as-needed basis as we make repairs or change out equipment that requires certification prior to use.

Radiographic Fluoroscopic X-ray Equipment Testing, Dose Rate Testing and Performance Monitoring (All April frequency cycle items in list below)

Testing and monitoring will conform to current VHA National Health Physics Program (NHPP) guidelines as noted in the references below.

Testing will include but not be limited to:

Measurement of radiation output parameters, including beam filtration

Testing of automatic control systems such as automatic exposure controls of radiographic systems and automatic exposure rate controls of fluoroscopy systems

Assessment of image quality

Measurement of appropriate indices of patient doses or dose rates at clinical technique factors with comparison to national standards

Measurement of minimum detectable activity of the Thyroid Uptake unit;

Monitoring will include but not be limited to:

A review of the quality control monitoring performed by technologists. The design will conform to the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiologic and Fluoroscopic Equipment and the ACR Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment , available from the American College of Radiology.

Appropriate indices of doses to patients, as estimated by the diagnostic radiological physicist for the technique factors used at the facility, must be posted at or near the control console for each x-ray imaging device.

For radiographic equipment, the entrance skin exposure, air kerma, or dose for a patient of typical size must be posted for common radiographic procedures.

For fluoroscopic equipment, the entrance skin exposure rate, air kerma rate, or dose rate must be posted for a typical range of patient sizes for common modes of operation, including various image magnification factors, boost mode, if available, continuous fluoroscopy, and for pulsed fluoroscopy at the available pulse rates.

For fluoroscopic equipment, the dose per image for each mode of image recording shall also be posted for a patient of typical thickness.

Leak Testing of Sealed Sources (All April/October Frequency Cycle Items in Paragraph 2.d. Equipment Listing):

Testing and recordkeeping requirements. Each licensee who uses a sealed source shall have the source tested for leakage periodically. The licensee shall keep a record of leak test results in units of micro curies and retain the record for inspection.

Method of testing. The wipe of a sealed source must be performed using a leak test kit. The wipe sample must be taken from the nearest accessible point to the sealed source where contamination might accumulate. The wipe sample must be analyzed for radioactive contamination.

Test frequency. (1) Each sealed source (except an energy compensation source (ECS)) must be tested at intervals listed (April/October). The Radiation Physicists will provide the wipe test kits, the analysis and the required report.

Equipment Listing:

Page 1 of 38

Page 15 of 39

Page 1 of 38

Freq

Fac

Room #

Nomenclature

Manufacturer

Model

Serial Number

VA AEMS MERS ID

Apr

FM

217A-145

RADIOG-FLUORO IMAGING SYST (R/F)

GE Healthcare

OEC ELITE

FBXXTE02427

568 MX3387487

Apr

FM

CS201I-113

R/F UNITS: MOBILE, OEC ELITE CFD (CART)

GE Healthcare

OEC ELITE CFD

FBXXTE03024

568 MX3580117

Apr

FM

S222-113

R/F UNITS: MOBILE, OEC ELITE CFD (CART)

GE Healthcare

OEC ELITE CFD

FBXXTE03025

568 MX3580118

Apr

FM

CS201I-113

R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM)

GE Healthcare

OEC ELITE CFD

X0034828007971

568 MX3580488

Apr

FM

S222-113

R/F UNITS: MOBILE, OEC ELITE CFD (C-ARM)

GE Healthcare

OEC ELITE CFD

X003482007868

568 MX3580489

Apr

FM

104-265

MRI

Siemens

Magnetom Sola

183215

MX2583351

Apr

FM

148-113

CT

Siemens

Definition AS

96286

MX665120

Apr

FM

154-113

Spec-CT

GE Healthcare

Optima NM/CT640

640Y25559

MX2037514

Apr

FM

143-113

Radiographic Systems

Samsung Electronics

GC85A

52RNM3RM900001J

MX2040652

Apr

FM

143-113

Radiographic Systems

Samsung Electronics

GC85A

55EVM3EM7000001W

MX2287241

Apr

FM

143-113

R/F System

Siemens

Axiom Luminous agile

61059

EE43067

Apr

FM

143-113

x-ray mobile

Samsung Electronics

GM85

55GFM31M400011K

MX1973107

Apr

FM

143-113

x-ray mobile

Samsung Electronics

GM85

55GFM31M400012E

MX1973112

Apr

FM

313OP2-145

xray Dental Intraoral

Sirona

Heliodent plus

17647

EE38836

Apr

FM

313OP3-145

xray Dental Intraoral

Sirona

Heliodent plus

31019665

MX663076

Apr

FM

317-145

xray handheld intraoral

Aseptico Inc

Nomad pro 2

1001091

MX1882089

Apr

FM

318-145

xray Panolypse

Planmeca

Promax S3 PAN

TPX356791

EE38863

Apr

FM

155-113

Dose Calibrator

Capintec Instruments

CRC-25R

250014

EE28935

Apr

FM

156-113

Thyroid Uptake System

Biodex Medical Systems

HIT-W151

KSA1590781

MX419236

Apr/Oct

FM

155-113

Cs137 .0001 curies

Capintec Instruments

CR-15E

S8117001-06

none

Apr/Oct

FM

155-113

Ba133 .000231 curies

Capintec Instruments

CR-178E

S8107001-04

none

Apr/Oct

FM

155-113

Co57 .99561 curies

RadQual

BM06E

BM06057E11278103

none

Apr

FM

127-113

Densitometers: Bone: X-Ray

GE Healthcare

Lunar IDXA

213130MA

MX3495174

Apr

RCBOC

Mobile

Mobile MRI

Siemens

Magnetom AERA

142349

MX2067566

Apr

RCBOC

1910

Radiographic System Digital

Phillips Corp

Digital Diagnost C90

22860092

MX2991885

Apr

HS

D020-12

Mobile Scanning Systems: CT

Siemens

SOMATOM DEFINITION AS

95402

EE43219

Apr

HS

B006-12

R/F System

Siemens

Axiom Luminous agile

61237

MX423229

Apr

HS

B002-12

Radiology System

Samsung Electronics

GC85A

52RNM3FM500001N

MX2047221

Apr

HS

B002-12

xray portable

Samsung Electronics

GM85

55GFM31M4000014D

MX1980227

Apr

HS

D112A-12

xray Panolypse

Planmeca

Promax S3 PAN

TPXV3062268

MX1655374

Apr

HS

D112B-12

xray Dental Intraoral

dentsply Sirona

Heliodent plus

63217

MX1958839

Apr

HS

D112C-12

xray Dental Intraoral

dentsply Sirona

Heliodent plus

63234

MX1958841

Apr

HS

D112E-12

xray Dental Intraoral

dentsply Sirona

Heliodent plus

63209

MX1958843

Apr/Oct

FM

155--113

CSs137 .000199 Curies

New England Nuclear

NES 356

3560180A-50

None

Apr/Oct

FM

155-113

Co60 .00005 curies

New England Nuclear

NES 354

3540579A-49

none

Apr/Oct

FM

155-113

Ba133 .00029 curies

New England Nuclear

NES 358

3580479A-02

None

Apr/Oct

FM

155-113

Co57

RadQual

BM06E-57

BM6057E12083117

None

Apr/Oct

FM

155-113

Co57

RadQual

BM01-10

BM011012088101

None

Training Requirements:

Appropriate vendor staff (as determined by the VA) performing the duties of the Statement of Work shall complete (print, review, and sign) the attached TMS 20939 No Access document. The Contractor shall send signed TMS 20939 documents to the Contracting Officer s Representative Jonathan Maruszewski at jonathan.maruszewski@va.gov.

Security:

The Contractor shall adhere to only the following IT security sections contained in the IT Contract Security Clause below (VHA Handbook 6500.6):

GENERAL

Working Hours:

Anticipated hours of work will be Monday through Friday from 7:00 am 4:00 pm. Additional hours must be coordinated through the COR/POC. Work will not be performed on weekends or federal holidays.

Observed Federal Holidays:

New Year s Day Martin Luther King Birthday

Washington s Birthday Memorial Day

Juneteenth Independence Day

Labor Day Columbus Day

Veteran s Day Thanksgiving Day

Christmas Day

References:

NHPP X-ray imaging guidance : http://nhpp.med.va.gov/NHPP_Diagnostic_Radiology_Info.asp

ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Computed Tomography (CT) Equipment.

ARC Technical Standard for Diagnostic Medical Physics Performance Monitoring of Radiological and Fluoroscopic Equipment.

NCRP Report #102 Medical X-ray, Electron Beam and Gamma-Ray Protection for Energies up to 50MeV (Equipment Design, Performance and Use)

NCRP Report # 147 Structural Shielding Design for Medical X-ray Imaging Facilities

NCRP Report # 99 Quality Assurance for Diagnostic Imaging Equipment

NRC NUREG 1556, Volume 9 Program-Specific Guidance About Medical Use Licenses.

Joint Commission Compliance Checklist: Diagnostic Imaging Standards: EC.02.01.01 - PI.02.01.01

Files

File Type Posted
36C26327Q0137.docx DOCX document

Similar open opportunities

Opportunity Agency Set-aside Responses due
Radiation Physics Support Services Virginia 23667, United States · NAICS 541380 Veterans Integrated Service Network 6 Service-Disabled Veteran-Owned Small Business
S207--BHVAHCS Building 65 Bat Mitigation Sources Sought Black Hills VA Health Care System Fort Meade Medical Center Fort Meade South Dakota 57741 · NAICS 561710 Veterans Integrated Service Network 23 No set-aside
VA - SOURCES SOUGHT: Radiation Dosimetry Supplies and Services United States · NAICS 541380 Veterans Integrated Service Network 20 No set-aside
Q301--Request For Information (RFI)-Reference Lab Testing for Fort Harrison VA Medical Center (Fort Harrison, MT) Department of Veterans Affairs Fort Harrison VA Medical Center Fort Harrison MT 59636 U.S.A. · NAICS 541380 Veterans Integrated Service Network 19 No set-aside
6525--SEP 2026 Equipment Only Consolidation NAICS 334517 National Acquisition Center No set-aside

On GovTribe

Work this opportunity

  • Track it in your pipeline
  • Find teaming partners
  • Similar opportunities
  • Ask GovTribe AI about this opportunity

GovTribe for Federal Contractors