113 Wing Fire Sprinkler and Fire Alarm
Closed Solicitation Posted
- Solicitation number
- W50S6W25Q0010
- Agency
- Army National Guard Department of the Army, Department of Defense
- Responses due
- Set-aside
- Total Small Business
Opportunity facts
- NAICS code
- 238210 Electrical Contractors and Other Wiring Installation Contractors
- Place of performance
- JB Andrews, Maryland 20762, United States
- Points of contact
-
- Stacey Little stacey.little.1@us.af.mil (240) 857-0076
Notice details come from SAM.gov. Updated .
About this opportunity
The Department of the Army National Guard is soliciting proposals for the design, fabrication, and installation of fire sprinkler and alarm systems at Joint Base Andrews, Maryland through solicitation W50S6W25-Q-0010. The contractor must provide a complete and operational fire sprinkler and alarm system within Building 1217's Operations Support Squadron area, with an optional line item to upgrade the existing fire alarm system in Building 2493. All work must comply with Joint Base Andrews design guidelines, International Building Code, National Electrical Code, NFPA standards, and OSHA requirements, with shop drawings subject to JBA Fire Department review and approval. The evaluation will be based on technical capability and past performance, which are equally weighted and considered more important than price in the award decision. The quote submission deadline is August 21, 2025 at 4:30 PM EST, with a mandatory site visit that occurred on August 8, 2025, and an anticipated contract award date of September 15, 2025.
This procurement is designated as a 100% small business set-aside under NAICS code 238210 (Electrical Contractors) with a $19 million size standard. While the solicitation documents reference an estimated value of approximately $69,313.48 for supplies and services based on earlier justification documents, no current contract value range is specified in the active solicitation. The contract will be awarded as a firm-fixed price agreement with a total duration not to exceed 18 months from award. Performance will take place at Joint Base Andrews, Maryland, specifically within the newly renovated secure area of Building 1217 and potentially Building 2493. The work involves modifying existing fire suppression systems, relocating sprinkler heads, implementing dielectric isolation, and installing new fire alarm notification appliances, with the optional Building 2493 work requiring replacement of the current Siemens fire alarm panel with a new Monaco MAAP-X panel for compatibility with the base's existing systems.
Notice text
4 versions
Update #4 · Latest ·
The purpose of this amendment is to update the attachement titled W0S6W-25-Q-0010_113OG_Fire Alarm Sprinkler_COMBO Updated 20 August 2025. The template pricelist refernecewd in paragraph 7.1.1 is NOT required rather the offerors may submit pricing in accordance with the CLIN structure in para. 1.11. See attached.
**********************************************************************************************************************
The purpose of this amendment is to upload the answers to questions, upload the floor plan of B1217 ( this is NO floor plan for B2493) , and uploaded the updated Statement of Work dated 19 August 2025.
***************************************************************************************************************************
The purpose of this amendment is to extend the quote due date from August 15, 2025 to August 21, 2025.
********************************************************************************************************************************
1. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued.
2. The contractor shall provide all materials, equipment, tools, parts, permits, transportation, personnel, labor, supervision, and management to perform the design, fabrication and installation of (1) a complete and operational Fire Sprinkler and Alarm System within the existing Operations Support Squadron Building located inside the newly renovated secure area located in Building 1217 and (2) as an OPTIONAL LINE ITEM, upgrade the existing Fire Alarm System located in Building 2493 Joint Base Andrews, MD 20762.
See attached for more details
Update #3 ·
The purpose of this amendment is to upload the answers to questions, upload the floor plan of B1217 ( this is NO floor plan for B2493) , and uploaded the updated Statement of Work dated 19 August 2025.
***************************************************************************************************************************
The purpose of this amendment is to extend the quote due date from August 15, 2025 to August 21, 2025.
********************************************************************************************************************************
1. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued.
2. The contractor shall provide all materials, equipment, tools, parts, permits, transportation, personnel, labor, supervision, and management to perform the design, fabrication and installation of (1) a complete and operational Fire Sprinkler and Alarm System within the existing Operations Support Squadron Building located inside the newly renovated secure area located in Building 1217 and (2) as an OPTIONAL LINE ITEM, upgrade the existing Fire Alarm System located in Building 2493 Joint Base Andrews, MD 20762.
See attached for more details
Update #2 ·
The purpose of this amendment is to extend the quote due date from August 15, 2025 to August 21, 2025.
********************************************************************************************************************************
1. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued.
2. The contractor shall provide all materials, equipment, tools, parts, permits, transportation, personnel, labor, supervision, and management to perform the design, fabrication and installation of (1) a complete and operational Fire Sprinkler and Alarm System within the existing Operations Support Squadron Building located inside the newly renovated secure area located in Building 1217 and (2) as an OPTIONAL LINE ITEM, upgrade the existing Fire Alarm System located in Building 2493 Joint Base Andrews, MD 20762.
See attached for more details
Update #1 ·
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes only solicitation; quotations are being requested, and a written solicitation will not be issued.
-
The contractor shall provide all materials, equipment, tools, parts, permits, transportation, personnel, labor, supervision, and management to perform the design, fabrication and installation of (1) a complete and operational Fire Sprinkler and Alarm System within the existing Operations Support Squadron Building located inside the newly renovated secure area located in Building 1217 and (2) as an OPTIONAL LINE ITEM, upgrade the existing Fire Alarm System located in Building 2493 Joint Base Andrews, MD 20762.
See attached for more details