WMA Midland HVAC Drawings #1021 - Pages 1-8 (Architectural).pdf
PDF 1 MB Posted
- Attached to
- WMA Midland Campus HVAC - RFP 1021
- Solicitation number
- RFP WMA 210000002377 3
- Issued by
- Macomb County, Whitehall City, Michigan
About this file
This document is a set of architectural HVAC drawings for Waterford Montessori Academy's Midland Campus located at 4860 Midland Avenue, Waterford, Michigan 48328. The project involves HVAC improvements to the existing educational facility, which comprises 25,338 square feet of gross floor area. The drawings were prepared by Ehresman Architects (Project No. 1021) and are dated for bidding and permits as of July 12, 2021. The scope includes installation of rooftop-mounted DOAS (Dedicated Outdoor Air Supply) units with manufactured roof curbs, indoor and outdoor heat pump systems, ductwork modifications, refrigerant piping distribution, new gas lines, and associated structural reinforcing. The work also encompasses mechanical equipment pads, metal enclosures for exposed piping, fence enclosure with security gates, and removal of existing heating infrastructure including boiler abandonment, water heater removal, and pneumatic control system decommissioning. The project design adheres to the Michigan Rehabilitation Code for Existing Buildings (2015 Edition), Michigan Building Code (2015 Edition), Michigan Mechanical Code (2015 Edition), National Electric Code (2017 Edition), and ASHRAE 90.1-2013 standards.
The drawings include composite floor and roof plans, enlarged floor plans for detailed coordination, reflected ceiling plans showing mechanical system locations, and roofing and fence details. General notes specify that the contractor must field-verify existing conditions, seal all penetrations with fire-rated sealants, match existing paint finishes, repair ceiling damage, and enclose exposed mechanical piping within sheet metal enclosures. Deferred submittals identified in the specification include fire alarm systems and duct detectors to be submitted by the registered design professional during construction supervision. The project contact is Jeremy Gilliam at Waterford Montessori Academy (248-674-2400, ext. 2). The drawings indicate coordination requirements with mechanical, electrical, and structural disciplines and note that not all drawing notes apply to each individual sheet.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
T
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
Waterford, MI, 48328
Location of Work (Represented by Shade)
Waterford Montessori Academy 4350 Elizabeth Lake, Rd.
Waterford, MI, 48328 Contact Name: Jeremy Gilliam Contact Phone: (248) 674-2400 ext. 2
ARCHITECT:
STRUCTURAL ENGINEER:
MECH. / ELECT. ENGINEER:
LOCATION PLAN
NOT TO SCALE
BUILDING KEY PLAN
NOT TO SCALE
APPLICABLE CODES:
MICHIGAN REHABILITATION CODE FOR EXISTING BUILDINGS: 2015 EDITION
MICHIGAN BUILDING CODE: 2015 EDITION
MICHIGAN PLUMBING CODE: 2015 EDITION
MICHIGAN MECHANICAL CODE: 2015 EDITION
NATIONAL ELECTRIC CODE (WITH MICHIGAN PART 8 RULES): 2017 EDITION
MICHIGAN UNIFORM ENERGY CODE: 2015 EDITION
ASHRAE 90.1-2013:
LIFE SAFETY CODE 101: 2012 EDITION
FEDERAL ADA LAW: CURRENT ED.
ACCESSIBLE AND USABLE BUILDINGS & FACILITIES (ANSI A117.1): 2009 EDITION
USE GROUP:
E - EDUCATION
ZONING DISTRICT:
R-1A, SINGLE FAMILY RESIDENTIAL
CONSTRUCTION TYPE:
III-B: ASSUMED
TOTAL FLOOR AREA:
TOTAL FLOOR AREA: 25,338 SF (GROSS FLOOR AREA)
WATERFORD MONTESSORI ACADEMY
Midland Campus (4860 Midland Ave.)
HVAC Improvements
LIST OF DRAWINGS
ARCHITECTURAL DRAWINGS:
TTL TITLE SHEET
A00 GENERAL INFORMATION
A20 COMPOSITE FLOOR & ROOF PLAN
A40 ENLARGED FLOOR PLAN(a) A41 ENLARGED FLOOR PLAN (b)
A60 ENLARGED RCP (a) A61 ENLARGED RCP (b)
A80 ROOFING & FENCE DETAILS
STRUCTURAL DRAWINGS:
S30 ROOF PLAN - AREA 1
S31 ROOF PLAN - AREA 2
S32 ENLARGED PLANS
MECHANICAL DRAWINGS:
M10 MECHANICAL COVER SHEET
M20 COMPOSITE FLOOR PLAN - MECHANICAL
M30 ENLARGED FLOOR PLAN - MECHANICAL
M31 ENLARGED FLOOR PLAN - MECHANICAL
M40 MECHANICAL SCHEDULES
M41 MECHANICAL SCHEDULES
M50 MECHANICAL DETAILS
M60 MECHANICAL SPECIFICATIONS
ELECTRICAL DRAWINGS:
E10 COMPOSITE FLOOR PLAN - ELECTRICAL
E20 COMPOSITE FLOOR PLAN - ELECTRICAL
E30 ELECTRICAL RISER DIAGRAM
E40 ELECTRICAL PANELBOARD SCHEDULES
E50 ELECTRICAL SPECIFICATIONS
DEFERRED SUBMITTALS:
PER SECTION 107.3.4.1, ANY REQUIRED SUBMITTALS WILL BE SUBMITTED TO THE AUTHORITY
HAVING JURISDICTION BY THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
ASSUMING THE DUTIES OF CONSTRUCTION SUPERVISION AT THE APPROPRIATE TIME.
DEFERRED SUBMITTALS:
1. FIRE ALARM SYSTEMS - DUCT DETECTORS
© Ehresman Architects
TTLProject No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Title Sheet
Bidding/Permits: 12 July 2021
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
LINE OF WALL
8"
CLEAR
MIN
18"
MIN
17"-19"(MIN-MAX)
(DIM. TO TOP OF SEAT)
VARIES
(B.F./STANDARD HT)
(BELOW)
DUPLEX OUTLET
(ABOVE)
FIRE ALARM
PULL BOX
BO
T.
OF
OU
TL
ET
HOOKS
TYPICAL MOUNTING HEIGHTS
SOAP
DISPENSER
" M
IN
" M
AX
SHOWERFIXTURES
PLUMBING
18" 22" 21 2"
MAX
BARRIER FREE
LAVATORY
WATER CLOSET
LINE OF WALL
18"
MIN
FIXTURES
PLUMBING
OR STALL
LINE OF WALL
16"-18"
17-19" AMBULATORY
BARRIER FREE
M
AX
IM
U
M
15" A.F.F. MINIMUM
ITEMS
SENIOR HOUSING
24" A.F.F. @
ELECTRICAL
SWITCH
LIGHT
48" A.F.F. MAXIMUM
ABBREVIATIONS
15" A.F.F. MINIMUM
VA
RI
ES
BY
G
RA
DE
LE
VE
L
ITEMS
GENERAL
ROD
48" A.F.F. MAXIMUM
CURTAIN
SHOWER
ACCESSORIES
TOILET ROOM
15" A.F.F. MINIMUM
SOAP
DISH
48" A.F.F. MAXIMUM
SHEET IDENTIFICATION NUMBER
B.F. CONTROLS ARE
OR ADJUSTABLE SPRAY
HOSE WITH HAND HELD
" M
IN
" M
AX15"
MIN 33
-3 6"
TO
T
OP
" M
IN
" M
AX
WASH FOUNTAINWASH FOUNTAIN
WALL MOUNTED
" M
AX
VANITY URINAL
" M
AX
WALL MOUNTED
TO BE MOUNTED 33" OR 36" A.F.F. TO
NEAR SINKS IN B.F. TOILET ROOMS
NOTE: ANY ELECTRICAL OUTLET
30"
B.F. MIN 18"
OBSTRUCTION
LINE OF
M
IN
LINE OF WALL
MOP STRIP
AND SHELF
PLAQUE
SIGNAGE
URINAL SCREEN
OR PARTITION
LINE OF WALL
17" (B.F. MIN)
19" (B.F. MAX)
FOLDED
POSITION
SHOWER SEATTOILET PAPER
3" MAX
LINE OF WALL
HOLDER
18" 18"
BARRIER FREE BARRIER FREE
39"-41"
GRAB BAR
LIGHT SWITCH
OUTLET WITH
ELECTRIC DUPLEX,
TELEPHONE, OR T.V.
(M
AX
IM
U
M
THERMOSTAT
BUTTONS
ELEVATOR
PUSH
CONTROLS 88
(O R
AS
N
OT
ED
(O R
AS
N
OT
ED
CLOCK
SPEAKER
WALL
15"
MAX
ST
AN
DA
RD
@ B.F. BATHTUB
OFFSET VALVES
LINE OF WALL
(S
TA
N
DA
RD
SHOWER HEAD
AND VALVESURINALURINAL
GRAB BAR
LINE OF WALL
OR PARTITION
BARRIER FREE
M
AX
M
AX 24
"51
M
AX
STANDARD
HAND HELD
ELECTRICAL OUTLET
SHOWER HEAD
AND CONTROLS
(SEE NOTE BELOW)
BARRIER FREE
M
AX
M
IN
5"
WALL C.O.
THIS AREA
MOUNTED WITHIN
" M
AX
IM
U M
TO
M
AI
N
S W
IT
CH80
ELECTRIC
OR PANEL PANEL
B.F. ELECTRIC
LINE OF WALL
UNIT ON BAR
59" MIN. LENGTH
DOOR IDENTIFICATIONROOM NAME AND NUMBER
OR NUMBER FOR EXISTING CONSTRUCTION
COLUMN IDENTIFICATION LETTER
OR NUMBER FOR NEW CONSTRUCTION
COLUMN IDENTIFICATION LETTER
COLUMN INDICATION
LINE OF
WALL BASE
A
C.O. COVER
NAME
ROOM
TRUE NORTH
N
NORTH INDICATION
TO REMAIN
DOOR SWING INDICATION
EXISTING DOOR
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE SECTION IS DRAWN)
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE SECTION IS DRAWN)
DOOR INDICATION
NEW DOOR
DOOR SWING INDICATION
MATCH LINE INDICATION
A20
A10 ZONE "A"
ZONE "B"
BE REMOVED
EXISTING DOOR TO
DOOR SWING INDICATION
ZONE "A"
ZONE "B" A20
A10
ONE TREAD DEPTH AT
BOTTOM OF STAIRS ONLY
12" MIN. TYPICAL
HORIZONTAL HANDRAIL
EXTENSION AT BOTTOM
OR TOP OF RAMP AND
TOP OF STAIR
" M
EN
/ 6
4" W
OM
EN
" C
H
IL
DR
EN
(1 2-
" C
H
IL
DR
EN
(1 5-
" B
.F
DISPENSER
B.
F.
H
AN
DL
E
H
EI
GH
T
SIZE AS NOTED
B.
F.
M
AX
BACKSPLASH
SHELVING
ST
D)
B.
F.
ST
AN
DA
RD
" KNOB OR
LEVER (B.F.)
HARDWARE
LC
SHELF
(BELOW)
WALL SLOT
(ABOVE)
SHELF
BAR AND
TOWEL TOWEL
BAR
HOOKSPURSE
BARRIER
B.F. SHELF
OR FREE DISPENSER
CUP
M
AX
IM
U
M
" S
TA
N
DA
RD
" M
AX
IM
U M
B .F
DRYER
HAIR
DRYER
HAND
TISSUE
FACIAL HANDRAIL
34"-38" TO TOP
ABOVE NOSING,
RAMP SURFACE, OR
WALKING SURFACE
END OF RAMP
LINE OF RISER OR
WASTE
RECEPTACLE
DISPENSER
" M
AX
TO
C
ON
TR
OL
TO
T
P
DISPENSER
SANITARY
DISPOSAL
NAPKIN
SEATSANITARY
NAPKIN COVER
" M
AX
(N
.T .S
AND WASTE
DISPENSER
RECEPTACLE
DISPENSER
UNIT
MULTIPURPOSE
OR
TOWEL
8"
MINTOWEL
MIRROR SIZE AS SPECIFIED OR NOTED
B.
F.
M
AX
TO
R
EF
L.
SU
RF
AC
E
B.
F.
M
IN
FULL LENGTH
BARRIER FREE
MIRROR
MIRROR AND
B.
F.
M
AX
MIRROR AND
TILTED MIRROR
SHELF OR
MIRROR,
LAV
20" B.F.
MIN
B.
F.
M
AX
B.
F.
M
AX
TO
R
EF
L.
SU
RF
AC
E
VANITY COUNTER
MIRROR AND
CHANGING
STATION
BABY
VARIES
A20
A20
INDICATES DIRECTION OF VIEW
SECTION IDENTIFICATION NUMBER
(NUMBER ON SHEET WHERE DRAWN OR REFERENCED)
ELEVATION IDENTIFICATION NUMBER
A20
1/4"=1'-0" Elevation Title
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE ELEVATION IS DRAWN)
(SHEET NUMBER WHERE SECTION IS DRAWN)
SHEET IDENTIFICATION NUMBER
ELEVATION INDICATION
A20
ELEVATION IDENTIFICATION
SECTION IDENTIFICATION NUMBER
SECTION LOCATION INDICATION
SECTION IDENTIFICATION NUMBER
(NUMBER ON SHEET WHERE DRAWN OR REFERENCED)
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE SECTION IS DRAWN)
A20
1/4"=1'-0" Section Title
DETAIL IDENTIFICATION NUMBER
(SHEET NUMBER WHERE ENLARGED PLAN IS DRAWN)
SHEET IDENTIFICATION NUMBER
SECTION IDENTIFICATION
A20
REFERENCE SYMBOLS
DETAIL LOCATION INDICATION FOR ENLARGED PLANS
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE DETAIL IS DRAWN)
DETAIL IDENTIFICATION NUMBER
SHEET IDENTIFICATION NUMBER
(SHEET NUMBER WHERE DETAIL IS DRAWN)
(NUMBER ON SHEET WHERE DRAWN OR REFERENCED)
DETAIL IDENTIFICATION NUMBER
A20
1/4"=1'-0" Detail Title
DETAIL LOCATION INDICATION
A20
WALL SECTIONS
DETAIL IDENTIFICATION
A20
PLAN SECTIONS
" M
EN
" W
OM
EN
" T
EE
N
AG
ER
" Y
OU
N G
CH
IL
D
" B .F
T.P. BELOW GB
M
IN
42"
MIN
12"
MAX
18" (B.F. MIN)
48" (B.F. MAX)
24"
MIN
12"
MIN
& ACCESSORIES
2"
MIN
24" MIN
-3
6"
TO
T
OP
54" MIN
36" MIN
& ACCESSORIES
MISCELLANEOUS ACCESSORIES, TOILET ACCESSORIES AND FIXTURES
NOTE: MOUNTING HEIGHTS SHOWN ARE PROPOSED FOR ALL ACCESSORIES AND FIXTURES REQUIRED UNLESS OTHERWISE NOTED OR DIMENSIONED ON DRAWINGS FOR SPECIFIC CONDITIONS (B.F. DENOTES BARRIER FREE REQUIREMENTS)
BASE AND UPPER
WALL CABINETS
CHALKBOARD OR
TACKBOARD
DOOR HARDWAREWALL MOUNTED OR
EMERGENCY TELEPHONE
(B.F. FRONT APPROACH)
FIRE EXTINGUISHER
CABINET
FIRE EXTINGUISHER AND
WALL BRACKET
WALL CABINET COAT ROD AND HAT
SHELF (ABOVE)
BOOT RACK (BELOW)
A
ABV. ABOVE
A.F.F. ABOVE FINISH FLOOR
ACC. ACCESS
ACC. PNL. ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADD. ADDENDUM
ADDN. ADDITION
ADJ. ADJACENT
A/C AIR CONDITIONING
A.C.C. AIR CONDITIONING COMPRESSOR
A.C.C.U. AIR COOLED CONDENSING UNIT
A.H.U. AIR HANDLING UNIT
AL ALIGN
ALT. ALTERNATE
ALUM./AL. ALUMINUM
ANCH. ANCHOR
A.B. ANCHOR BOLT
& AND
ANG./L OR ∠ ANGLE
ANOD. ANODIZED
APT. APARTMENT
APPR. APPROVED
APPROX. APPROXIMATE
ARCH. ARCHITECT/ARCHITECTURAL
A.T.M. AUTOMATIC TELLER MACHINE
ASPH. ASPHALT
ASSY. ASSEMBLY
@ AT
AUTO. AUTOMATIC
AUX. AUXILIARY
AVG. AVERAGE
B
B/B. BACK TO BACK
B.F.P. BACK FLOW PREVENTER
B.D.D. BACK DRAFT DAMPER
B.F. BARRIER FREE
B.B.R BASE BOARD RADIATION
B. PL BASE PLATE
BSMT. BASEMENT
BM BEAM
B/C BACK OF CURB
BRG BEARING
B.M. BENCHMARK
BT BENT
BETW. BETWEEN
BEV. BEVEL
BIT. BITUMINOUS
B.I. BLACK IRON
BLK BLOCK
BLKG BLOCKING
BD BOARD
BLR BOILER
BK. SH. BOOK SHELVES
BOT. BOTTOM
BOT. EL. BOTTOM ELEVATION
BLVD. BOULEVARD
BDRY BOUNDARY
BRKT BRACKET
BTU BRITISH TERMINAL UNIT
BLDG. BUILDING
B.U.R. BUILT UP ROOFING
BUZZ. BUZZER
C
CAB. CABINET
CAP. CAPACITY
CAR. CARPET
C (CONTINUED):
C.T. CAST IRON
C.B. CATCH BASIN
CLG. CEILING
CLG. HT. CEILING HEIGHT
CEM. CEMENT
CEM. PLAS. CEMENT PLASTER
CTR CENTER
℄ CENTER LINE
CER. CERAMIC
C.T. CERAMIC TILE
C.BD. CHALKBOARD
CHAN. OR CHANNEL
CHWE CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CIRCUM. CIRCUMFERENCE
CR. BRK. CIRCUIT BREAKER
CL CLASSROOM
C.O. CLEANOUT
CLR. CLEAR
CL. CLOSER
CW COLD WATER
COL. COLUMN
CO. COMPANY
CA COMPRESSED AIR
CONC. CONCRETE
C.M.U. CONCRETE MASONRY UNITS
CWR COLD WATER RETURN
CWS COLD WATER SUPPLY
COND. CONDUIT
CONF. CONFERENCE
CONST. CONSTRUCTION
C.J. CONTROL JOINT
CONT. CONTINUE/CONTINUOUS
CONTR. CONTRACTOR
C.P. CONTROL PANEL
CONV. CONVECTOR
CRS. COURSE
COV. COVER
COV. PL COVER PLATE
CU. FT CUBIT FEET/CUBIC FOOT
CFV CONTRACTOR FIELD VERIFY
CULV CULVERT
CYL. CYLINDER
CYC. CYCLE(S)
CIRCUM. CIRCUMFERENCE
D
DMPR DAMPER
DMPG DAMPPROOFING
D.L. DEAD LOAD
DB DECIBEL
D. DEEP
DMT. PARTN. DEMOUNTABLE PARTITION
DEPT. DEPARTMENT
DEPR. DEPRESSED
DES. DESIGN
DET. DETAIL
D.E.C. DETROIT EDISON COMPANY
DIAG. DIAGONAL
DIA. OR Ø DIAMETER
DIFF. DIFFUSER
DIM. DIMENSION
DIR. DIRECTION
DISC. DISCONNECT
DW DISHWASHER
DISP. DISPENSER
DIST. DISTANCE
D.P. DISTRIBUTION PANEL
DIV. DIVIDER/DIVISION
D (CONTINUED):
DR. DOOR
D.O. DOOR OPENING
DR. OP DOOR OPERATOR
DBL. DOUBLE
D.H. DOUBLE HUNG
DWL. DOWEL
DN. DOWN
D.S. DOWNSPOUT
DRN. DRAIN
D.T. DRAIN TILE
D.T.C. DRAIN TILE CONNECTOR
DWR DRAWER
DWG DRAWING
D.F. DRINKING FOUNTAIN
DUP DUPLICATE
E
EA EACH
E.F. EACH FACE
E.W. EACH WAY
E EAST
E.I.F.S. EXTERIOR INSULATION FINISH SYSTEM
ELAST. ELASTOMETRIC
ELEC. ELECTRIC/ELECTRICAL
ELEC. CAB. ELECTRICAL CABINET
E.C. ELECTRICAL CONTRACTOR
E.P. ELECTRICAL PANEL
E.W.C. ELECTRIC WATER PANEL
ELEC. OPER. ELECTRICALLY OPERATED
EL. ELEVATION
ELEV. ELEVATOR
EMERG. EMERGENCY
ENCL. ENCLOSURE
ENGR. ENGINEER
ENTR. ENTRANCE
EP. EPOXY
EPDM. ETHYLENE PROPYLENE DIENE MONOMER
EQ. EQUAL
EQUIP. EQUIPMENT
EQUIV. EQUIVALENT
ESC. ESCALATOR
EST. ESTIMATE
EXC. EXCAVATED
EXH. EXHAUST
E.F. EXHAUST FAN
(E) EXISTING
E.C.U. EXISTING CONDITIONS UNKNOWN
ETR EXISTING TO REMAIN
EXP. EXPANSION
E.J. EXPANSION JOINT
EXP'D EXPOSED
EXT'N EXTENSION
EXT EXTERIOR
E.H. EXTRA HEAVY
EXTR. EXTRUDED
F
FAB FABRICATED
F.FIN. FACTORY FINISH
FAS. FASTENER
FT OR' FOOT OR FEET
FPM FEET PER MINUTE
FN FENCE
F.V. FIELD VERIFY
FIG FIGURE
FIN. FINISH/FINISHED
FIN. FLR/ F.F. FINISHED FLOOR
F.A. FIRE ALARM
F (CONTINUED):
F.D. FIRE DAMPER
F.E. FIRE EXTINGUISHER
F.E.C. FIRE EXTINGUISHER CABINET
FLASH FLASHING
F.C. FLEXIBLE CONNECTION
FLR FLOOR
F.C.O. FLOOR CLEANOUT
F.D. FLOOR DRAIN
FLR. FIN FLOOR FINISH
FLUOR. FLUORESCENT
FTG FOOTING
FDN FOUNDATION
FR FRAME
FRMG FRAMING
FRZR. FREEZER
FURN. FURNISH
FURR. FURRING
FUT. FUTURE
G
GA. GAUGE
GALV. GALVANIZED
G. GAS
GSKT GASKET
G.V. & B. GATE VALVE AND BOX
G.R. GUARD RAIL
GEN'L GENERAL
GL. GLASS/GLAZING
G.H.T. GLAZED HARD TILE
G.B. GRAB BAR
GRN GRANITE
G.T. GREASE TRAP
GND GROUND
G.F.I. GROUND FAULT INTERRUPTER
GT GROUT
GYP. GYPSUM
GYP. BD. GYPSUM BOARD
H
H.C. HANDICAPPED
H.R. HANDRAIL
HDW HARDWARE
HDWD. HARDWOOD
HD HEAD
HDR. HEADER
HTR HEATER
H/V HEATING AND VENTILATING
H.V.A.C HEATING, VENTILATING & AIR CONDITIONING
HHWR HEATING HOT WATER RETURN
HHWS HEATING HOT WATER SUPPLY
HT HEIGHT
HEX. HEXAGON
H. HIGH
H.I.D. HIGH INTENSITY DISCHARGE
H.P. HIGH POINT
H.PR. HIGH PRESSURE
H.S. HIGH STRENGTH
H.V. HIGH VOLTAGE
HWY HIGHWAY
H.C. HOLLOW CORE
H.M. HOLLOW METAL
HK HOOK
HORIZ. HORIZONAL
HO HORSEPOWER
H.B. HOSE BIB
H.W. HOT WATER
H.W.H. HOT WATER HEATER
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
H (CONTINUED):
HR HOUR
HYD. HYDRANT
I
I.D. INSIDE DIMENSION
INCAND. INCANDESCENT
IN. OR " INCH(ES)
INCL. INCLUDE/INCLUDING
I/W INDIRECT WASTER
INFO INFORMATION
INST'L INSTALL/INSTALLATION
INSUL INSULATE/INSULATION
INT. INTERIOR
INTER. INTERMEDIATE
INV. INVERT
I.E. INVERT ELEVATION
J
J.C. JANITOR CLOSET
JT JOINT
JST JOIST
J.B. JUNCTION BOX
K
K.P. KICKPLATE
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
K KIP (1000#)
KIT. KITCHEN
K.D. KNOCKDOWN
K.O.P. KNOCK OUT PANEL
L
LBL. LABEL
LAB. LABORATORY
LAD. LADDER
L.B. LAG BOLT
LAM. LAMINATE/LAMINATED
LDG LANDING
LGE LARGE
LDRY LAUNDRY
LAV. LAVATORY
L.H. LEFT HAND
LGTH OR L LENGTH
LEV LEVEL
LT. LIGT
LTG LIGHTING
L.P. LIGHTING PANEL
LMS LIMESTONE
LTL LINTEL
L.F. LINEAR FOOT/FEET
LIQ. LIQUID
L.L. LIVE LOAD
LOC. LOCATION
LG LONG
L.L.H. LONG LEG HORIZONTAL
L.L.V. LONG LEG VERTICAL
LVR LOUVER
L.O. LOUVER OPENING
L.P. LOW POINT
L.PR. LOW PRESSURE
LBS. OR # POUNDS
M
MACH. MACHINE
M.A.U. MAKE-UP AIR UNIT
M.D.P. MAIN DISTRIBUTION PANEL
M.S.B MAIN SWITCH BOARD
MAINT. MAINTENANCE
M.H. MANHOLE
MFR. MANUFACTURER
MAR. MARBLE
M.O. MASONRY OPENING
MAX. MAXIMUM
MECH. MECHANICAL
NED. MEDIUM
MEMB. MEMBRANE
MET. METAL
M.D.S. METAL DIVIDER STRIP
M.E. METAL EDGE
M.L. METAL LATH
M.L.&PLAS. METAL LATH & PLASTER
M.T. MARBLE THRESHOLD
MEZZ. MEZZANINE
MDOT MICHIGAN DEPARTMENT OF TRANSPORTATION
MIN. MINIMUM
MISC. MISCELLANEOUS
MTD MOUNTED
MTG MEETING
N
NRC NOISE REDUCTION COEFFICIENT
NOM. NOMINAL
N. NORTH
N.I.C NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. OR # NUMBER
O
OBS OBSCURE
O.C. ON CENTER
OPQ. OPAQUE
OPG. OPENING
OPER. OPERATOR
OPP. OPPOSITE
ORN. ORNAMENTAL
OZ. OUNCE
O.A. OUTSIDE AIR
O.D. OUTSIDE DIAMETER
O.A. OVERALL
OHD OVERHEAD
O.F. OVERFLOW
P
PTD PAINTED
PR PATCH AND REPAIR
PNL PANEL
P.T.D. PAPER TOWEL DISPENSER
PKG PARKING
P.BD. PARTICLE BOARD
PASS. PASSAGE
PVMT PAVEMENT
PED PEDESTAL
PERF. PERFORATED
PLAS. PLASTER
P.LAM. PLASTIC LAMINATE
PL. PLATE
PLBG PLUMBING
PLWD PLYWOOD
PT POINT
POL. POLISH(ED)
PVC POLYVINYLCHLORIDE
P (CONTINUED):
PORC. PORCELAIN
PORC.ENAM. PORCELAIN ENAMEL
POR. POROUS
PLF POUNDS PER LINEAR FOOT
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PCF POUNDS PER CUBIC FOOT
P.P. POWER PANEL
P/C PRECAST
PREFAB PREFABRICATE
PFN. PREFINISHED
P.T. PRESSURE TREATED
P.G. PRESSURE GAUGE
P.R.V. PRESSURE REDUCING VALVE
PRIM. PRIMARY
PROJ. PROJECT/PROJECTION
PROP. PROPERTY/PROPOSED
P.L. PROPERTY LINE
P.A. PUBLIC ADDRESS
P.S. PURSE SHELF
P.B. PUSH BUTTON
Q
QTY QUANTITY
Q.T. QUARRY TILE
QTR QUARTER
QTR.RD. QUARTER ROUND
R
R. RISER
RAD. OR R. RADIUS
R.C. ROOF CONDUCTOR
R.R. RAILROAD
REF. REFER/REFERENCE
REFL. REFLECT(ED)
REFR. REFRIGERATOR
REINF. REINFORCE(MENT)
REQ'D REQUIRED
R.A. RETURN AIR
REV. REVISED/REVISION
RPM REVOLUTIONS PER MINUTE
R.H. RIGHT HAND
R.O.W. RIGHT OF WAY
RD ROAD
RF ROOF
R.D. ROOF DRAIN
R.S. ROOF SUMP
R.T.U. ROOFTOP UNIT
RM ROOM
R.O. ROUGH OPENING
R.B. RUBBER BASE
S
SAN. SANITARY
S.N.D. SANITARY NAPKIN DISPENSER
S.N.R. SANITARY NAPKIN RECEPTACLE
SCHED. SCHEDULE
STG. SEATING
SEC SECTION
SERV. SERVICE
SHT SHEET
SHWR SHOWER
SIM SIMILAR
S.D. SOAP DISPENSER
S.C. SOLID CORE
STC SOUND TRANSMISSION CLASS
S SOUTH
S (CONTINUED):
S SOUTH
SP SPACE
SPKR SPEAKER
SPEC. SPECIFICATIONS
SQ. SQUARE
S.F. SQUARE FEET
S.S. STAINLESS STEEL
STD STANDARD
STM STEAM
STL STEEL
STOR STORAGE
ST. STREET
STRUCT. STRUCTURAL
SUSP. SUSPEND(ED)
SWBD SWITCHBOARD
SWGR SWITCHGEAR
SYM. SYMBOL
SYS. SYSTEM
T
T.BD TACKBOARD
TECH TECHNICAL
TEL. TELEPHONE
TV TELEVISION
TEMP TEMPORARY
TERR. TERRAZZO
T. THERMOSTAT
THRU THROUGH
T&G TONGUE AND GROOVE
T&B TOP AND BOTTOM
T/C TOP OF CURB
T/F TOP OF FOOTING
T/G TOP OF GUTTER
TRFR TRANSFORMER
T TREAD
T.D. TRENCH DRAIN
TYP. TYPICAL
U
U.C. UNDERCUT
U.G. UNDERGROUND
UL UNDERWRITER'S LABORATORY
UNFIN. UNFINISHED
U.H. UNIT HEATER
U.V. UNIT VENTILATOR
U.N.O. UNLESS NOTED OTHERWISE
UR URINAL
V
VAR VARIABLE
VARN. VARNISH
VNR. VENEER
V. VENT
VTR VENT THRU ROOF
V.I.F. VERIFY IN FIELD
V.M. VERIFY WITH MANUFACTURER
VS VERSUS
VERT. VERTICAL/VERTICALLY
VEST. VESTIBULE
VCT VINYL COMPOSITION TILE
V.R.S. VINYL REDUCER STRIP
VIT. VITREOUS
VOL. VOLUME
V VOLTS
W
WAINS. WAINSCOT
W.C.O WALL CLEANOUT
W.H. WALL HYDRANT
W.V. WALL VENT
W.F. WASH FOUNTAIN
W. WASTE
W.C. WATER CLOSET
W.H. WATER HEATER
WP WATERPROOF
WT. WEIGHT
W.W.F. WELDED WIRE FABRIC
W WEST
W. WIDE/WIDTH
W.B. WALL BASE
W.O. WINDOW OPENING
W.M. WIRE MESH
W/ WITH
W/O WITHOUT
WD WOOD
W.P. WORKING POINT
Y
YD YARD
Y.P. YIELD POINT
Y.S. YIELD STRENGTH
YR YEAR
Z
ZC ZINC
-3
9"
34" MAX TO
SURFACE WHEN
OPEN
-4
3"
ST
AN
DI
N G
PE
RS
ON
S
" B
.F
5" MAX 15"
MAX
DRINKING FOUNTAIN
SPOUT LOCATION
8" MIN
" M
IN
9" MIN
11"
MIN
KNEE CLEARANCE
6" MAX
9" MIN
TOE CLEARANCE
© Ehresman Architects
A00Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
General Information
Bidding/Permits: 12 July 2021
A
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
GM
© Ehresman Architects
A20Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Composite Floor & Roof Plan
Bidding/Permits: 12 July 2021
Scale: 1/16"=1'-0" Composite Floor Plan
A20
A41 A40
A41 A40
Scale: 1/16"=1'-0" Composite Roof Plan
A20
GENERAL NOTES:
ROOFTOP MOUNTED DOAS WITH MANUFACTURED ROOF CURB UNIT FLASHED IN TO EXISTING
ROOF WITH COMPATIBLE MATERIALS. PROVIDE STRUCTURAL REINFORCING. PROVIDE
POSITIVE DRAINAGE TO PREVENT WATER PONDING. REFER TO MECHANICAL AND
STRUCTURAL DRAWINGS AND 1/A80.
DRAWING NOTES:
1.
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G3. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS.
G4. ALL PENETRATIONS TO BE SEALED WITH APPROVED FIRE RATED SEALANT.
G5. ALL PAINT TO MATCH EXISTING ADJACENT SURFACES ONE COAT PRIMER WITH TWO COATS
PAINT SUITABLE FOR APPLICATION AT AREAS OF NEW WORK AND REPAIR OF DAMAGED
AREAS.
G6. REPAIR DAMAGE TO PLASTER CEILING OR REPLACE DAMAGED CEILING TILES TO MATCH
EXISTING IN AREAS OF NEW WORK.
G7. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO PENETRATING ROOF, WALLS, OR
CEILING TO AVOID DISTURBING STRUCTURAL MEMBERS.
G8. REMOVE EXISTING PLASTER CEILING, CEILING TILES, AND ASSOCIATED FRAMING NECESSARY
TO ALLOW FOR THE INSTALLATION OF NEW STRUCTURAL OR MECHANICAL COMPONENTS,
PATCH AND REPAIR CEILING AFTER INSTALLATION FOR A NEAT AND FINISHED APPEARANCE.
G9. MISC. CAULK - AT NON-FIRE RATED PENETRATIONS WITH POLYURETHANE SEALANT OR
PAINTABLE CAULK. COLOR TO MATCH ADJACENT SURFACES.
G10. ALL EXPOSED TO VIEW PIPING SHALL BE ENCLOSED WITHIN A SHEET METAL ENCLOSURE.
CONTRACTOR SHALL FURNISH AND INSTALL ALL VERTICAL AND HORIZONTAL METAL
ENCLOSURES COMPLETE WITH APPROPRIATE FITTINGS INCLUDING, BUT NOT LIMITED TO END
CAPS, INTERNAL AND EXTERNAL ELBOWS, ETC. ALL FITTINGS SHALL BE FURNISHED BY THE
SAME ENCLOSURE MANUFACTURER (SIMILAR TO WIREMOLD, SERIES 6000). ANCHOR
SECURELY TO WALL/CEILING PER MANUFACTURER'S REQUIREMENTS FOR APPLICATION.
MANUFACTURER'S FINISH TO BE SUITABLE FOR FIELD REPAINTING TO MATCH
SURROUNDINGS. PAINT (2) FINISH COATS OVER MANUFACTURER'S PRIMER FINISH.
COORDINATE WITH MECHANICAL DRAWINGS TO PROVIDE REQUIRED ENCLOSURES SIZED TO
ACCOMMODATE QUANTITY, SIZE, AND CONFIGURATION OF INSULATED MECHANICAL PIPING.
2.
RTU ON CONCRETE EQUIPMENT PAD. REFER TO STRUCTURAL DRAWINGS. COORDINATE
LOCATION WITH BUILDING ENGINEER.
3.
4.
5.
6.
COORDINATE LOCATION OF TEMPERATURE CONTROL DEVICE. REFER TO MECHANICAL
DRAWINGS.
7.
8.
UNITIZED INSULATED PIPE CURB, MIN 18" HIGH. FLASH IN TO EXISTING ROOF WITH
COMPATIBLE MATERIALS. REFER TO MECHANICAL DRAWINGS AND 1/A80.
NOT ALL NOTES APPLICABLE TO THIS SHEET.G2.
OUTDOOR DUCTWORK. REFER TO MECHANICAL DRAWINGS.
REFRIGERANT PIPING. REFER TO MECHANICAL DRAWINGS.
OUTDOOR HEAT PUMP ON ROOF EQUIPMENT SUPPORTS. PROVIDE SUPPORT PADS AT EACH
LEG THAT ARE COMPATIBLE WITH EXISTING ROOFING MATERIAL. REFER TO MECHANICAL
DRAWINGS.
9.
NEW GAS LINE TO ROOF TOP EQUIPMENT FROM EXISTING SERVICE. REFER TO MECHANICAL
DRAWINGS.
INDOOR HEAT PUMP MOUNTED HIGH ON WALL. REFER TO MECHANICAL DRAWINGS.
TOILET
KINDERGARTEN
STORAGE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
BOILER ROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
GIRLS
BOYS
STORAGE
JANITOR
STORAGE
OPEN OFFICE
OFFICE
OFFICE
CORRIDOR
6a
CLASSROOM
6b
CLASSROOM
OFFICE
LAB
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
VESTIBULE
GIRLS LOCKER
BOYS LOCKER
KITCHEN30
STORAGE
GYM
STORAGE
YARD
GYM
STAGE
FAN ROOM
STORAGE
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
BELOW
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
TYP
AutoCAD SHX Text
TYP
© Ehresman Architects
A40Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Enlarged Floor Plan (a)
Bidding/Permits: 12 July 2021
Scale: 1/8"=1'-0" Enlarged Floor Plan (a)
A40
A41 A40
A41 A40
DRAWING NOTES:
1.
2.
RTU ON CONCRETE EQUIPMENT PAD. REFER TO STRUCTURAL AND MECHANICAL DRAWINGS.
COORDINATE LOCATION WITH BUILDING ENGINEER.
3.
4.
5.
6.
COORDINATE LOCATION OF TEMPERATURE CONTROL DEVICE. REFER TO MECHANICAL
DRAWINGS.
8.
METAL ENCLOSURE TO CONCEAL MECHANICAL PIPING. FIRE SEAL ALL PENETRATIONS FROM
BOTH SIDES. PAINT TO MATCH EXISTING WALL. REFER TO G10.
9.
EXISTING TO REMAIN:
BOILER (ABANDON IN PLACE).E1.
WATER HEATER.E2.
MOP SINK.E3.
PNEUMATIC CONTROLS COMPRESSOR AND AIR DRYER.E4.
HEAT PUMPS.E5.
NEW MAIN SWITCHBOARD. REFER TO ELECTRICAL DRAWINGS.
NEW BUCK BOOST TRANSFORMER. REFER TO ELECTRICAL DRAWINGS.
OUTDOOR DUCTWORK WITH LINTEL. REFER TO MECHANICAL AND STRUCTURAL DRAWINGS.
NON-SCALABLE FENCE ENCLOSURE WITH GATES AND DROP ROD. REFER TO A80.
10.
UNIT VENTILATOR (ABANDON IN PLACE).E6.
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G3. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS.
G4. ALL PENETRATIONS TO BE SEALED WITH APPROVED FIRE RATED SEALANT.
G5. ALL PAINT TO MATCH EXISTING ADJACENT SURFACES ONE COAT PRIMER WITH TWO COATS
PAINT SUITABLE FOR APPLICATION AT AREAS OF NEW WORK AND REPAIR OF DAMAGED
AREAS.
G6. REPAIR DAMAGE TO PLASTER CEILING OR REPLACE DAMAGED CEILING TILES TO MATCH
EXISTING IN AREAS OF NEW WORK.
G7. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO PENETRATING ROOF, WALLS, OR
CEILING TO AVOID DISTURBING STRUCTURAL MEMBERS.
G8. REMOVE EXISTING PLASTER CEILING, CEILING TILES, AND ASSOCIATED FRAMING NECESSARY
TO ALLOW FOR THE INSTALLATION OF NEW STRUCTURAL OR MECHANICAL COMPONENTS,
PATCH AND REPAIR CEILING AFTER INSTALLATION FOR A NEAT AND FINISHED APPEARANCE.
G9. MISC. CAULK - AT NON-FIRE RATED PENETRATIONS WITH POLYURETHANE SEALANT OR
PAINTABLE CAULK. COLOR TO MATCH ADJACENT SURFACES.
G10. ALL EXPOSED TO VIEW PIPING SHALL BE ENCLOSED WITHIN A SHEET METAL ENCLOSURE.
CONTRACTOR SHALL FURNISH AND INSTALL ALL VERTICAL AND HORIZONTAL METAL
ENCLOSURES COMPLETE WITH APPROPRIATE FITTINGS INCLUDING, BUT NOT LIMITED TO END
CAPS, INTERNAL AND EXTERNAL ELBOWS, ETC. ALL FITTINGS SHALL BE FURNISHED BY THE
SAME ENCLOSURE MANUFACTURER (SIMILAR TO WIREMOLD, SERIES 6000). ANCHOR
SECURELY TO WALL/CEILING PER MANUFACTURER'S REQUIREMENTS FOR APPLICATION.
MANUFACTURER'S FINISH TO BE SUITABLE FOR FIELD REPAINTING TO MATCH
SURROUNDINGS. PAINT (2) FINISH COATS OVER MANUFACTURER'S PRIMER FINISH.
COORDINATE WITH MECHANICAL DRAWINGS TO PROVIDE REQUIRED ENCLOSURES SIZED TO
ACCOMMODATE QUANTITY, SIZE, AND CONFIGURATION OF INSULATED MECHANICAL PIPING.
NOT ALL NOTES APPLICABLE TO THIS SHEET.G2.
NEW GAS LINE TO GRADE MOUNTED RTU FROM EXISTING SERVICE. REFER TO MECHANICAL
DRAWINGS.
INDOOR HEAT PUMP MOUNTED HIGH ON WALL DIRECTLY BELOW CEILING. REFER TO
MECHANICAL DRAWINGS.
INDOOR DUCTWORK, CONNECT TO EXISTING INTERIOR DUCTWORK. REFER TO MECHANICAL
DRAWINGS.
7.
NEW POWER PANEL. REFER TO ELECTRICAL DRAWINGS.11.
TOILET
KINDERGARTEN
STORAGE
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
BOILER ROOM
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
GIRLS
BOYS
STORAGE
JANITOR
STORAGE
OPEN OFFICE
OFFICE
OFFICE
CORRIDOR
6a
CLASSROOM
6b
CLASSROOM
OFFICE
LAB
CLASSROOM
SURFACE MOUNTED GRILLE FOR SUPPLY AIR BELOW LAY-IN CEILING. REMOVE CMU BLOCK
FOR NOMINAL 16X8 DUCT OPENING. REFER TO MECHANICAL DRAWINGS
12.
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E1
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text E5
AutoCAD SHX Text E5
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
X
X
X
X
X
X
X X
X X
X X
X X
X X
X
X X X X X X X X X X X X X X X X X X X X X X X X X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X
X
X
X
X
X
X
X
© Ehresman Architects
A41Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Enlarged Floor Plan (b)
Bidding/Permits: 12 July 2021
Scale: 1/8"=1'-0" Enlarged Floor Plan (b)
A41
A40 A41
A41 A40
DRAWING NOTES:
1.
2.
RTU ON CONCRETE EQUIPMENT PAD. REFER TO STRUCTURAL AND MECHANICAL DRAWINGS.
COORDINATE LOCATION WITH BUILDING ENGINEER.
3.
4.
5.
6.
COORDINATE LOCATION OF TEMPERATURE CONTROL DEVICE. REFER TO MECHANICAL
DRAWINGS.
8.
METAL ENCLOSURE TO CONCEAL MECHANICAL PIPING. FIRE SEAL ALL PENETRATIONS FROM
BOTH SIDES. PAINT TO MATCH EXISTING WALL. REFER TO G10.
9.
EXISTING TO REMAIN:
BOILER (ABANDON IN PLACE).E1.
WATER HEATER.E2.
MOP SINK.E3.
PNEUMATIC CONTROLS COMPRESSOR AND AIR DRYER.E4.
HEAT PUMPS.E5.
NEW MAIN SWITCHBOARD. REFER TO ELECTRICAL DRAWINGS.
NEW BUCK BOOST TRANSFORMER. REFER TO ELECTRICAL DRAWINGS.
OUTDOOR DUCTWORK WITH LINTEL. REFER TO MECHANICAL AND STRUCTURAL DRAWINGS.
NON-SCALABLE FENCE ENCLOSURE WITH GATES AND DROP ROD. REFER TO A80.
10.
UNIT VENTILATOR (ABANDON IN PLACE).E6.
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G3. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS.
G4. ALL PENETRATIONS TO BE SEALED WITH APPROVED FIRE RATED SEALANT.
G5. ALL PAINT TO MATCH EXISTING ADJACENT SURFACES ONE COAT PRIMER WITH TWO COATS
PAINT SUITABLE FOR APPLICATION AT AREAS OF NEW WORK AND REPAIR OF DAMAGED
AREAS.
G6. REPAIR DAMAGE TO PLASTER CEILING OR REPLACE DAMAGED CEILING TILES TO MATCH
EXISTING IN AREAS OF NEW WORK.
G7. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO PENETRATING ROOF, WALLS, OR
CEILING TO AVOID DISTURBING STRUCTURAL MEMBERS.
G8. REMOVE EXISTING PLASTER CEILING, CEILING TILES, AND ASSOCIATED FRAMING NECESSARY
TO ALLOW FOR THE INSTALLATION OF NEW STRUCTURAL OR MECHANICAL COMPONENTS,
PATCH AND REPAIR CEILING AFTER INSTALLATION FOR A NEAT AND FINISHED APPEARANCE.
G9. MISC. CAULK - AT NON-FIRE RATED PENETRATIONS WITH POLYURETHANE SEALANT OR
PAINTABLE CAULK. COLOR TO MATCH ADJACENT SURFACES.
G10. ALL EXPOSED TO VIEW PIPING SHALL BE ENCLOSED WITHIN A SHEET METAL ENCLOSURE.
CONTRACTOR SHALL FURNISH AND INSTALL ALL VERTICAL AND HORIZONTAL METAL
ENCLOSURES COMPLETE WITH APPROPRIATE FITTINGS INCLUDING, BUT NOT LIMITED TO END
CAPS, INTERNAL AND EXTERNAL ELBOWS, ETC. ALL FITTINGS SHALL BE FURNISHED BY THE
SAME ENCLOSURE MANUFACTURER (SIMILAR TO WIREMOLD, SERIES 6000). ANCHOR
SECURELY TO WALL/CEILING PER MANUFACTURER'S REQUIREMENTS FOR APPLICATION.
MANUFACTURER'S FINISH TO BE SUITABLE FOR FIELD REPAINTING TO MATCH
SURROUNDINGS. PAINT (2) FINISH COATS OVER MANUFACTURER'S PRIMER FINISH.
COORDINATE WITH MECHANICAL DRAWINGS TO PROVIDE REQUIRED ENCLOSURES SIZED TO
ACCOMMODATE QUANTITY, SIZE, AND CONFIGURATION OF INSULATED MECHANICAL PIPING.
NOT ALL NOTES APPLICABLE TO THIS SHEET.G2.
NEW GAS LINE TO GRADE MOUNTED RTU FROM EXISTING SERVICE. REFER TO MECHANICAL
DRAWINGS.
INDOOR HEAT PUMP MOUNTED HIGH ON WALL DIRECTLY BELOW CEILING. REFER TO
MECHANICAL DRAWINGS.
INDOOR DUCTWORK, CONNECT TO EXISTING INTERIOR DUCTWORK. REFER TO MECHANICAL
DRAWINGS.
7.
NEW POWER PANEL. REFER TO ELECTRICAL DRAWINGS.11.
CLASSROOM
CLASSROOM
CLASSROOM
CLASSROOM
CORRIDOR
VESTIBULE
GIRLS LOCKER
BOYS LOCKER
KITCHEN30
STORAGE
GYM
STORAGE
YARD
GYM
STAGE
FAN ROOM
STORAGE
SURFACE MOUNTED GRILLE FOR SUPPLY AIR BELOW LAY-IN CEILING. REMOVE CMU BLOCK
FOR NOMINAL 16X8 DUCT OPENING. REFER TO MECHANICAL DRAWINGS
12.
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text T
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E6
AutoCAD SHX Text E6
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
A60Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Enlarged Reflected Ceiling Plan (a)
Bidding/Permits: 12 July 2021
Scale: 1/8"=1'-0" Enlarged Reflected Ceiling Plan (a)
A60
A61 A60
A61 A60
LAY-IN CEILING GRID AND TILE TO REMAIN UNLESS NOTED OTHERWISE.
EXISTING TO REMAIN:
E1.
LIGHT FIXTURES.E2.
SUPPLY AIR DIFFUSERS.
E3.
RETURN AIR GRILL.
E4.
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G3. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS.
G4. ALL PENETRATIONS TO BE SEALED WITH APPROVED FIRE RATED SEALANT.
G5. ALL PAINT TO MATCH EXISTING ADJACENT SURFACES ONE COAT PRIMER WITH TWO COATS
PAINT SUITABLE FOR APPLICATION AT AREAS OF NEW WORK AND REPAIR OF DAMAGED
AREAS.
G6. REPAIR DAMAGE TO PLASTER CEILING OR REPLACE DAMAGED CEILING TILES TO MATCH
EXISTING IN AREAS OF NEW WORK.
G7. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO PENETRATING ROOF, WALLS, OR
CEILING TO AVOID DISTURBING STRUCTURAL MEMBERS.
G8. REMOVE EXISTING PLASTER CEILING, CEILING TILES, AND ASSOCIATED FRAMING NECESSARY
TO ALLOW FOR THE INSTALLATION OF NEW STRUCTURAL OR MECHANICAL COMPONENTS,
PATCH AND REPAIR CEILING AFTER INSTALLATION FOR A NEAT AND FINISHED APPEARANCE.
G9. MISC. CAULK - AT NON-FIRE RATED PENETRATIONS WITH POLYURETHANE SEALANT OR
PAINTABLE CAULK. COLOR TO MATCH ADJACENT SURFACES.
G10. ALL EXPOSED TO VIEW PIPING SHALL BE ENCLOSED WITHIN A SHEET METAL ENCLOSURE.
CONTRACTOR SHALL FURNISH AND INSTALL ALL VERTICAL AND HORIZONTAL METAL
ENCLOSURES COMPLETE WITH APPROPRIATE FITTINGS INCLUDING, BUT NOT LIMITED TO END
CAPS, INTERNAL AND EXTERNAL ELBOWS, ETC. ALL FITTINGS SHALL BE FURNISHED BY THE
SAME ENCLOSURE MANUFACTURER (SIMILAR TO WIREMOLD, SERIES 6000). ANCHOR
SECURELY TO WALL/CEILING PER MANUFACTURER'S REQUIREMENTS FOR APPLICATION.
MANUFACTURER'S FINISH TO BE SUITABLE FOR FIELD REPAINTING TO MATCH
SURROUNDINGS. PAINT (2) FINISH COATS OVER MANUFACTURER'S PRIMER FINISH.
COORDINATE WITH MECHANICAL DRAWINGS TO PROVIDE REQUIRED ENCLOSURES SIZED TO
ACCOMMODATE QUANTITY, SIZE, AND CONFIGURATION OF INSULATED MECHANICAL PIPING.
NOT ALL NOTES APPLICABLE TO THIS SHEET.G2.
E5.
PLASTER CEILING TO REMAIN UNLESS NOTED OTHERWISE.
DRAWING NOTES:
1.
2.
3.
4.
5.
6.
7.
REFRIGERANT PIPING ABOVE LAY-IN CEILING. REFER TO MECHANICAL DRAWINGS.
REFRIGERANT DISTRIBUTION UNIT ABOVE LAY-IN CEILING. REFER TO MECHANICAL
DRAWINGS.
SUPPLY AIR GRILLE. REFER TO MECHANICAL DRAWINGS.
RETURN AIR GRILLE. REFER TO MECHANICAL DRAWINGS.
OUTDOOR DUCTWORK WITH LINTEL. REFER TO MECHANICAL AND STRUCTURAL DRAWINGS.
INDOOR HEAT PUMP MOUNTED HIGH ON WALL DIRECTLY BELOW CEILING. REFER TO
MECHANICAL DRAWINGS.
INDOOR DUCTWORK, CONNECT TO EXISTING INTERIOR DUCTWORK. REFER TO MECHANICAL
DRAWINGS.
REMOVE HOT WATER HEATING MAINS FROM CORRIDOR ONCE NEW HEATING IS FUNCTIONAL.
REFER TO MECHANICAL DRAWINGS.
8.
9. OPEN END DUCT.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
E2
A61Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Enlarged Reflected Ceiling Plan (b)
Bidding/Permits: 12 July 2021
Scale: 1/8"=1'-0" Enlarged Reflected Ceiling Plan (b)
A61
A60 A61
A61 A60
DRAWING NOTES:
1.
2.
3.
4.
5.
6.
7.
LAY-IN CEILING GRID AND TILE TO REMAIN UNLESS NOTED OTHERWISE.
EXISTING TO REMAIN:
E1.
LIGHT FIXTURES.E2.
REFRIGERANT PIPING ABOVE LAY-IN CEILING. REFER TO MECHANICAL DRAWINGS.
REFRIGERANT DISTRIBUTION UNIT ABOVE LAY-IN CEILING. REFER TO MECHANICAL
DRAWINGS.
SUPPLY AIR GRILLE. REFER TO MECHANICAL DRAWINGS.
RETURN AIR GRILLE. REFER TO MECHANICAL DRAWINGS.
SUPPLY AIR DIFFUSERS.
E3.
RETURN AIR GRILL.
E4.
OUTDOOR DUCTWORK WITH LINTEL. REFER TO MECHANICAL AND STRUCTURAL DRAWINGS.
GENERAL NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
G3. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS.
G4. ALL PENETRATIONS TO BE SEALED WITH APPROVED FIRE RATED SEALANT.
G5. ALL PAINT TO MATCH EXISTING ADJACENT SURFACES ONE COAT PRIMER WITH TWO COATS
PAINT SUITABLE FOR APPLICATION AT AREAS OF NEW WORK AND REPAIR OF DAMAGED
AREAS.
G6. REPAIR DAMAGE TO PLASTER CEILING OR REPLACE DAMAGED CEILING TILES TO MATCH
EXISTING IN AREAS OF NEW WORK.
G7. CONTRACTOR SHALL FIELD VERIFY CONDITIONS PRIOR TO PENETRATING ROOF, WALLS, OR
CEILING TO AVOID DISTURBING STRUCTURAL MEMBERS.
G8. REMOVE EXISTING PLASTER CEILING, CEILING TILES, AND ASSOCIATED FRAMING NECESSARY
TO ALLOW FOR THE INSTALLATION OF NEW STRUCTURAL OR MECHANICAL COMPONENTS,
PATCH AND REPAIR CEILING AFTER INSTALLATION FOR A NEAT AND FINISHED APPEARANCE.
G9. MISC. CAULK - AT NON-FIRE RATED PENETRATIONS WITH POLYURETHANE SEALANT OR
PAINTABLE CAULK. COLOR TO MATCH ADJACENT SURFACES.
G10. ALL EXPOSED TO VIEW PIPING SHALL BE ENCLOSED WITHIN A SHEET METAL ENCLOSURE.
CONTRACTOR SHALL FURNISH AND INSTALL ALL VERTICAL AND HORIZONTAL METAL
ENCLOSURES COMPLETE WITH APPROPRIATE FITTINGS INCLUDING, BUT NOT LIMITED TO END
CAPS, INTERNAL AND EXTERNAL ELBOWS, ETC. ALL FITTINGS SHALL BE FURNISHED BY THE
SAME ENCLOSURE MANUFACTURER (SIMILAR TO WIREMOLD, SERIES 6000). ANCHOR
SECURELY TO WALL/CEILING PER MANUFACTURER'S REQUIREMENTS FOR APPLICATION.
MANUFACTURER'S FINISH TO BE SUITABLE FOR FIELD REPAINTING TO MATCH
SURROUNDINGS. PAINT (2) FINISH COATS OVER MANUFACTURER'S PRIMER FINISH.
COORDINATE WITH MECHANICAL DRAWINGS TO PROVIDE REQUIRED ENCLOSURES SIZED TO
ACCOMMODATE QUANTITY, SIZE, AND CONFIGURATION OF INSULATED MECHANICAL PIPING.
NOT ALL NOTES APPLICABLE TO THIS SHEET.G2.
INDOOR HEAT PUMP MOUNTED HIGH ON WALL DIRECTLY BELOW CEILING. REFER TO
MECHANICAL DRAWINGS.
INDOOR DUCTWORK, CONNECT TO EXISTING INTERIOR DUCTWORK. REFER TO MECHANICAL
DRAWINGS.
E5.
PLASTER CEILING TO REMAIN UNLESS NOTED OTHERWISE.
REMOVE HOT WATER HEATING MAINS FROM CORRIDOR ONCE NEW HEATING IS FUNCTIONAL.
REFER TO MECHANICAL DRAWINGS.
8.
9. OPEN END DUCT.
AutoCAD SHX Text
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E3
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text E4
AutoCAD SHX Text
AutoCAD SHX Text E5
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E4
AutoCAD SHX Text E5
AutoCAD SHX Text E1
AutoCAD SHX Text E2
AutoCAD SHX Text
AutoCAD SHX Text E1
E2
MINIMUM SIZES FOR MONTAGE II POSTS
GENERAL NOTES:
DRAWING NOTES:
DO NOT SCALE DRAWING. DRAWING SCALE IS SHOWN FOR GENERAL REFERENCE ONLY.G1.
LINE OF ROOF.
EXISTING TO REMAIN:
E1.
© Ehresman Architects
A80Project No. 1021
Waterford Montessori Academy Midland Campus (4860 Midland Ave.)
HVAC Improvements
Roofing & Fence Details
Bidding/Permits: 12 July 2021
DECK MEMBRANE SHALL BE FASTENED AROUND PERIMETER OF ROOF PENETRATION AS PER
RESPECTIVE ZONE THE RECTANGULAR PENETRATION IS LOCATED WITHIN (FIELD, PERIMETER,
CORNER). AS AN ALTERNATIVE TO DECK FASTENING, PLATES/FASTENERS MAY BE FASTENED
TO THE CURB. PLATES/FASTENERS ARE TO BE DURO-LAST APPROVED.
1.
TERMINATION BAR SHALL HAVE AN APPROVED DURO-LAST FASTENER WITHIN 1 INCH OF
EACH CORNER. FASTENERS SHOULD BE SPACED 6 INCHES O.C.
2.
ALL FIELD WELDS SHALL BE A MINIMUM OF 1-1/2 INCHES WIDE.3.
REFER TO SPECIFICATIONS FOR APPROVED VAPOR BARRIER, INSULATION AND COVER BOARD
REQUIREMENTS.
4.
ANY APPROVED MEMBRANE PLATE MAY BE USED. IT IS RECOMMENDED TO USE 3-INCH METAL
PLATES OR CLEAT PLATES®.
5.
LINE OF DECK.E2.
APPROVED DURO-LAST CAULK®.6.
APPROVED DURO-LAST SEALANT.7.
APPROVED DURO-LAST ADHESIVE.8.
Scale: 6"=1'-0" Rectangular Penetration Detail
A80
RECTANGULAR PENETRATION.9.
DURO-LAST CUSTOM-FABRICATED CURB FLASHING.10.
8" M
IN
Scale: NTS Wireworks Panel
A80
Scale: NTS Wireworks Double Gate Arrangement
A80
Scale: NTS Impasse II Rail
A80
Scale: NTS Impasse II Rail
A80
STAINLESS STEEL SECURITY FASTENER TO PREVENT TAMPERING OR REMOVAL BY NORMAL
TOOLS.
11.
WIREWORKS ANTI-CUT/ANTI-CLIMB WELDED WIRE MESH PANELS.12.
IMPASSE II RAIL - SPECIALLY FORMED, HIGH-STRENGTH ARCHITECTURAL SHAPE; LOWER LIP
CONTOURED TO CARRY - STEEL CABLE AND/OR SENSOR CABLES FOR SECURITY.
13.
IMPASSE POST - SPECIALLY FORMED I-BEAM, PRE-PUNCHED FOR MULTIPLE RAIL OPTIONS.14.
BASE MATERIAL.15.
UNIFORM ZINC COATING (HOT DIP).16.
ZINC PHOSPHATE COATING AND CONVERSION COATING.17.
EPOXY PRIMER.18.
"NO-MAR" POLYESTER POWDER FINISH COAT.19.
3" x .5" x 10.5GA (8'-0" HEIGHT) ANTI-CLIMB WIREWORKS MESH.20.
POST SIZE = 3" x 2.75" x 12GA I-BEAM.21.
2" x 12GA IMPASSE II RAIL.22.
WELD ON BOX HINGE.23.
2" SQ. x 12GA GATE UPRIGHT.24.
2" SQ. x 12GA RAIL.25.
3"
LATCH CLEARANCE
4'-0"
8' -0
1 8" S
TA
N
DA
RD
H
EI
GH
T 2"
3' -0
" M
IN
. P
OS
T
EM
BE
DM
EN
T
8'-3" OVERALL
2"
HINGE CLEARANCE
2"
HINGE CLEARANCE
8' -0
" S
TA
N
DA
RD
H
EI
GH
T
2"
3' -0
" M
IN
. P
OS
T
EM
BE
DM
EN
T
3"
2"
8'-0" O.C. ±
3' -4
" M
IN
. F
OO
TI
N
G
DE
PT
H
3' -4
" M
IN
. F
OO
TI
N
G
DE
PT
H
GATE LATCH WITH PADLOCK HASP, DROP ROD AND RECEIVER.26.
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text E2
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
File details come from the government source that posted it. Updated .