WILLIAMSTOWN HVAC DRAWING.pdf

PDF 12 MB Posted

Attached to
Construction: HVAC - Williamstown WVANG
Solicitation number
CRFQ-0603-ADJ2500000042-3
Issued by
Upshur County, West Virginia

About this file

The file contains an HVAC inventory and mechanical drawing set for a facility located in Parkersburg, West Virginia, specifically for the Williamstown location. The document includes a comprehensive inventory of 13 Rooftop Units (RTUs) and 3 Heating and Ventilating Units (HVUs), predominantly manufactured by Trane, with one unit from an anonymous manufacturer. The inventory details each unit's specifications, including model numbers, serial numbers, voltage, refrigerant type, belt size, filter size, and the specific room or area of use. Additional documents include a barometric relief vents chart and detailed mechanical equipment placement drawings showing the location of RTU-7 and associated air handling equipment.

The technical drawings provide precise spatial information about the HVAC system layout, including duct sizes, equipment positioning, and room designations such as facility maintenance, corridor, and various room types. The units are primarily 460-volt, three-phase systems using refrigerants like R22 and R-410A, with filter sizes ranging from 16x20x2 to 24x24x2. The document appears to be part of a facilities management or potential HVAC replacement/upgrade project, with the drawings dated 8/9/02 and originating from Parkersburg, West Virginia. The comprehensive nature of the documentation suggests a thorough assessment of the existing HVAC infrastructure for potential maintenance, replacement, or system optimization.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

HVAC INVENTORY usl( S FOR THE FACILITIES

Facility: Manufacturer of unit model serial voltage single or 3 phase Refrigerant belt 'iize filter size room use Condition

RTUJ YSC048 345100120 460 N/A

i------·----

RTU1 YSC048 345100206 460

3 R22 3.81bs

3 R22 3.Slbs N/A rnu11 YSC072 344101497 460 3 R22 7L8s AX31 RTUS YSC090 345100226 460 3 R22 11.5 LB AX3l

RTU6

Trane

Trane Trane Trane

YSC048 345100128 460 3 R22 3.8 LB N/A

RTU7 ANON 50311 200312ANG 460 3 R-4228 13.3 N/A

20x30x1{2 1, lass room

20x25x1(2 Medical 16x25x2(4 104th 16X25x2(4 BN 20x25x1{2 r.wm

24x24x2(8 Drill floor

RTUS Trane YSC048 3451.00127 460 3 R22 3.8L8s N/A 20x2Sx1(2 Hallway HTU9 Trane YCC018 34520WF2 460 3 R22 3.75LB N/A 20x20xl(l medical supply RTUJO ·1 rane YSC102 345100182 460 3 R22 7LBs AX34 20x25x2(4 library RTU] 1 Trcrne YCD150D4 34510041D 460 3 R22 9.4LBs BX62 20X20x2(2 kitchen 20x25x2(4)

RTU12 T1·ane YSC033 16111003 460 3 R-410A 3.2 N/A custom(2) lab

RTU13 Trane YCD150 345100400 460 3 R22 9.4lB) BXG2 2bx2Sx2(4 classroom 2Dx20x2(2) HVU#l Trane GRAA10 345100127 460 3 N/A /\J8 16x20x2 supply

HVU#2 Trnne GRCA25 F03K09354 460 3 N/A A41 20x20x2 maintnance bay

:HVl.1#3 Trc1ne GRCA30 F031<09356 460 3 N/A B40 1 Gx20x2 locker room