SCVS__Enhancement_SoW.pdf
PDF 311 KB Posted
- Solicitation number
- W91364-15T-0011
About this file
SFE Statement of Work SCVS Enhancement
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Questions_with_answers_for_OH_HRF_SCVS_for_April_22_2015.docx | DOCX document | |
| Camp_Sherman.zip | ZIP file | |
| Camp_Ravenna.zip | ZIP file | |
| Camp_Ravenna_and_Camp_Sherman_SCVS_locations.docx | DOCX document | |
| Questions_with_answers_for_OH_HRF_SCVS_as_of_April13_2015.docx | DOCX document | |
| Questions_with_answers_for_OH_SFEs_April_10_2015.docx | DOCX document | |
| Annex_A-enhancement.pdf | ||
| Annex_B-enhancement.pdf | ||
| 2015_SFE__Statement_of_Work_SCVS_reset_support.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NGOH-TAL-LO 20 OCT 2014
STATEMENT OF WORK
Inspection, Enhancement and Certification of Structural Collapse Venue Simulators
1. Background: The Structural Collapse Venue Simulators (SCVS) located in Ohio are existing SCVS which have been used multiple times for various Chemical Biological Radiological Nuclear training events. As a result of these training events some components have become degraded and need to be evaluated for replacement.
2. Project Scope: Inspection, enhancement and certification of existing SCVS located at Camp Ravenna Joint Maneuver Training Center (CRJMTC) and Camp Sherman Joint Training Center
(CSJTC).
3. Objective: Increase training value of current Structural Collapse Venue Simulators.
4. Structural Collapse Venue Simulator Survey: The contractor shall conduct a technical inspection of each SCVS in order to determine viability and training value of current construction material and props and identify all items that require replacement.
SCVS Site one (1) o Location: Camp Ravenna Joint Maneuver Training Center, Point of
Contact is: MAJ Saphore, 614-336-6790 richard.b.saphore.mil@mail.mil
SVCS Site two (2) o Location: Camp Sherman Joint Training Center, 2154 Narrows RD, Chillicothe, OH 45601-9688 o Point of contact is SFC Barnhart, Range Control Operations Camp
Sherman, 614-336-6460
5. Structural Collapse Venue Simulator Inspection and Certification: The contractor shall inspect each SCVS to ensure all construction material and props are in such a condition that provides optimal training value, replacing those items that fail to meet criteria identified in Annex A and removing any vegetation that may be present within the SCVS itself.
6. Structural Collapse Venue Simulator Enhancement: The Contractor shall evaluate each SCVS for the addition of construction material and props as identified in Annex B.
7. Props: Props must create the appearance of a “real world” collapsed structure allowing National Guard Units to develop experience and expertise in real disasters.
8. Environmental Considerations:
a. No petroleum products can be used for fill/construction.
b. No subterranean excavating is allowed.
c. No alteration is permitted of the surrounding trees or vegetation.
d. Contractor must abide by all local, state and Federal environmental regulations and laws.
9. Completion Dates: Contractor will have all replacement and additional items placed and certified for use NLT date 15 May 2015
10. Point of Contact: Point of contact for this statement of work is CPT Joseph Myers, 614-336-
4293,joseph.m.myers14.mil@mail.mil
WAYNE A. THOMAS
MAJ, LG, OHARNG
HRF LOGISTICS OFFICER
File details come from the government source that posted it. Updated .