NY_ANG__-_FTU_Bldg_641_-_ANG_Sustainable_Design_Score_Sheet_.pdf

PDF 131 KB Posted

Attached to
Addition to Flight Training Unit Building 641
Solicitation number
W912PQ-19-B-8001
Issued by

About this file

Sustainable Design Score Sheet

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ANGETL 15-01-01, 1 May 15

Air National Guard Sustainable Design and Energy Conservation Score Sheet VERSION (ANG v2015(1) ) LEED® 2009 * required entry

General Information HAAW169006 Project Number (e.g. ABCD123456) Add to Flight Training Unit Building 641

Project Title

Major Renovation and/or Addition Project Category Hancock Field ANGB Base Name Syracuse City * New York State * United States CONUS *

- PM Name $0.00 PA ($k) 9,200 Building Size (SF) 2018 Program Year (FY####) B-3 Project Phase 2017 Design Started (FY####)

2/15/2018 BOD (MM/DD/YY)

Not in pursuit of LEED Pursuing formal LEED® Certification

LEED® 2009 LEED® Rating System 49 LEED® Points Status ANG Silver Certifiable LEED® Certification Level Goal Per ANG Design Instruction Certified LEED® Certification Level Status N/A LEED® Energy and Water Points Status N/A LEED® Access ID 68% HPSB Compliant 0% Water Conservation Achieved (% below EPAct 1992) 30% Energy Efficiency Achieved (% below ANSI/ASHRAE/IESNA

Standard 90.1-2010) 17% LEED® Energy and Water Points Awarded by GBCI 4/5/2016 All LEED General Information complete 5/24/2018 Automatic Date Yes EPAct 2005 Compliant 11/16/2018 Date Scoresheet Completed or Revised * 2 Scoresheet version

Color Coding: See Instructions Tab for more detail Recommended (not required) Yes or N/A Maybe

LEED Prerequisite No

* required entry

Federal Requirements for High Performance and Sustainable Buildings (HPSB) & UFC 1-200-02 HPSB I: Employ Integrated Design Principles (UFC 1-200-02 para 2-2)

1 Possible Points 2 No HPSB I.1 Integrated Design 1 * Yes HPSB I.2 Commissioning 1 *

1 Possible Points (HPSB only) 1 Yes UFC para 2-3.1 Site selection 1 * Yes UFC para 2-3.2 Mitigation of Heat Island Effect 1 * Yes UFC para 2-3.3 Reduction of Light Pollution 1 * Yes HPSB III.3-4 Stormwater Management 1 *

No Entry Required Custom Entry

Drop-Down Box

Fees ($)

Registration Certification

Date Project Registered (MM/DD/YY)

Date Project Certified by GBCI (MM/DD/YY)

LEED Points Awarded by GBCI (e.g. 42)

LEED Certification Level Awarded by GBCI

0.17 LEED Energy and Water Points Awarded by GBCI

Attachment 2 v2015(1) - 1

VERSION (ANG v2015(1) ) LEED® 2009 * required entry

2 Possible Points 4 Yes HPSB II.1 1

Yes Reduce energy use 30% below ANSI/ASHRAE/IESNA Standard 90.1-2010 or if not - achieve maximum energy efficiency that is lifecycle cost effective

30.1% Insert percentage below ANSI/ASHRAE/IESNA Standard 90.1-2010 in terms of energy use (e.g. 32)

Insert building energy intensity (kBtu/yr-sqft) calculated IAW 10 CFR

No HPSB II.2 1

No Installed solar hot water heater system or found installation not lifecycle cost effective

0.0 Insert generation capacity (MMBtu/yr)

0.0% Insert percentage of demand No HPSB II.3 1

No Installed renewable energy elements or projects were not lifecycle cost effective

Renewable energy types (check below)

0.0 Insert generation capacity (kW)

0.0% Insert percentage of total building Yes HPSB II.4 1

Yes Water Metering: Select N/A if no service * Yes Electric Metering: Select N/A if no service * Yes Natural Gas Metering: Select N/A if no service * N/A Steam Metering: Select N/A if no service

HPSB III: Protect and Conserve Water (UFC 1-200-02 para 2-5) 2 Possible Points 3

Yes HPSB III.1 Indoor Water 1 * N/A HPSB III.2 Outdoor Water 1 * M/A HPSB III.4 Water Used for Heating and Cooling 1

N/A Water efficient measures were implemented with heating and cooling equipment when life cycle effective

HPSB IV: Enhance Indoor Environmental Quality (UFC 1-200-02 para 2-6) 5 Possible Points 6

Yes HPSB IV.1 Thermal Comfort 1 * Yes HPSB IV.2 Ventilation 1 * Yes HPSB IV.3 1 * No HPSB IV.4 Daylighting 1 * Yes HPSB IV.5 Low Emitting Materials 1 * Yes HPSB IV.6 Protect Indoor Air Quality during Construction 1 * Yes HPSB IV.7 Environmental Tobacco Smoke *

4 Possible Points 6 Yes HPSB V.1 Recycled Content 1 * No HPSB V.2 Biologically-based Products 1 * No HPSB V.3 Environmentally Preferable Products 1 * Yes HPSB V.4 Waste and Materials Management - Recycling 1 * Yes HPSB V.5 Waste and Materials Management, Divert 50% from Disposal 1

75.0% Insert percentage diverted from landfill * Yes Data element is not applicable *

Yes HPSB V.6 Ozone Depleting Substances 1 * Possible Points 22

15 Federal Requirements - Yes or N/A 0 Federal Requirements - Maybe 8 Federal Requirements - No

68% Percentage of Federal Requirements Met

Moisture Control

Solar PV

Solar CP

Solar Thermal Electric

Geothermal

GSHP Wind

Hydro Waste to Energy

Renewables were not

Attachment 2 v2015(1) - 2

VERSION (ANG v2015(1) ) LEED® 2009 * required entry

LEED® Credits and/or Prerequisites that meet HPSB/UFC Requirements LEED® Credits and/or Prerequisites that align closely with HPSB/UFC Requirements LEED® Credits that meet ANG Energy & Water Criteria (may depend on technologies & strategies)

Sustainable Sites 11 Possible Points 26

Yes Prereq 1 Construction Activity Pollution Prevention (HPSB GP3) Required Yes Credit 1 1 No Credit 2 5 No Credit 3 1 No Credit 4.1 6 Yes Credit 4.2 1 Yes Credit 4.3 3 Yes Credit 4.4 2 No Credit 5.1 1 No Credit 5.2 1 Yes Credit 6.1 1 No Credit 6.2 1 Yes Credit 7.1 Heat Island Effect - Non-Roof (UFC) 1 Yes Credit 7.2 Heat Island Effect - Roof (UFC) 1 Yes Credit 8 1

Option 1 Select which LEED® Interior Lighting Option was used Water Efficiency

6 Possible Points 10 Yes Prereq 1 Required

4 Credit 1 Water Efficient Landscaping (HPSB GP3) 2 to 4 2 Reduce Potable Water Use by 50% (HPSB GP3) 2 4 No Potable Use or Irrigation (HPSB GP3) 2

No Credit 2 2 2 Credit 3 Water Use Reduction (HPSB GP3) 2 to 4

2 30% Reduction (HPSB GP3) 2 3 35% Reduction (HPSB GP3) 1 4 40% Reduction (HPSB GP3) 1

Energy & Atmosphere 3 Possible Points 35

Yes Prereq 1 Required Yes Prereq 2 Minimum Energy Performance (HPSB GP2) Required Yes Prereq 3 Fundamental Refrigerant Management (HPSB GP5) Required

3 Credit 1 Optimize Energy Performance (HPSB GP2) 1 to 19 1 12% for New Buildings/8% for Existing Building Renovations 1 2 14% for New Buildings/10% for Existing Building Renovations 1 3 16% for New Buildings/12% for Existing Building Renovations 1 4 18% for New Buildings/14% for Existing Building Renovations 1 5 20% for New Buildings/16% for Existing Building Renovations 1 6 22% for New Buildings/18% for Existing Building Renovations 1 7 24% for New Buildings/20% for Existing Building Renovations 1 8 26% for New Buildings/22% for Existing Building Renovations 1 9 28% for New Buildings/24% for Existing Building Renovations 1

10 30% for New Buildings/26% for Existing Building Renovations 1 11 32% for New Buildings/28% for Existing Building Renovations 1 12 34% for New Buildings/30% for Existing Building Renovations 1 13 36% for New Buildings/32% for Existing Building Renovations 1 14 38% for New Buildings/34% for Existing Building Renovations 1 15 40% for New Buildings/36% for Existing Building Renovations 1 16 42% for New Buildings/38% for Existing Building Renovations 1 17 44% for New Buildings/40% for Existing Building Renovations 1 18 46% for New Buildings/42% for Existing Building Renovations 1 19 48%+ for New Buildings/44%+ for Existing Building Renovations 1

0 Credit 2 On-Site Renewable Energy (HPSB GP2) 1 to 7 1 On-site 1% 1 2 On-site 3% 1 3 On-site 5% 1 4 On-site 7% 1 5 On-site 9% 1 6 On-site 11% 1 7 On-site 13% 1

No Credit 3 2 No Credit 4 2 No Credit 5 3 No Credit 6 2

Enhanced Commissioning (HPSB GP1)

Site Selection Development Density & Community Connectivity

Alternative Transportation - Public Transportation Access

Innovative Wastewater Technologies

Water Use Reduction - 20% Reduction (HPSB GP3)

Stormwater Design - Quantity Control (HPSB GP3) Stormwater Design - Quality Control (HPSB GP3)

Alternative Transportation - Low-Emitting & Fuel Efficient Vehicles

Enhanced Refrigerant Management (HPSB GP5) Measurement & Verification (HPSB GP2) Green Power

Site Development - Maximize Open Space

Alternative Transportation - Parking Capacity Site Development - Protect or Restore Habitat

LEED® 2009 Checklist

Fundamental Commissioning of the Building Energy Systems (HPSB GP1)

Brownfield Redevelopment

Alternative Transportation - Bicycle Storage & Changing Rooms

Attachment 2 v2015(1) - 3

VERSION (ANG v2015(1) ) LEED® 2009 * required entry

11 Possible Points 14 Yes Prereq 1 Storage & Collection of Recyclables (HPSB GP5) Required

3 Credit 1.1 Building Reuse - Maintain Existing Walls Floors & Roof 1 to 3 1 Maintain 55% of Existing Walls Floors & Roof 1 2 Maintain 75% of Existing Walls Floors & Roof 1 3 Maintain 95% of Existing Walls Floors & Roof 1

Yes Credit 1.2 1 2 Credit 2 Construction Waste Management (HPSB GP5) 1 to 2

1 50% Recycled or Salvaged 1 2 75% Recycled or Salvaged 1

0 Credit 3 Materials Reuse 1 to 2 1 5% of value of material reused content 1 2 10% of value of material reused content 1

2 Credit 4 1 to 2 1 10% of value of material recycled content 1 2 20% of value of material reused content 1

2 Credit 5 Regional Materials 1 to 2 1 10% Extracted, Processed & Manufactured 1 2 20% Extracted, Processed & Manufactured 1

No Credit 6 1 Yes Credit 7 1

10 Possible Points 15 Yes Prereq 1 Minimum IAQ Performance (HPSB GP4) Required Yes Prereq 2 Environmental Tobacco Smoke (ETS) Control (HPSB GP4) Required Yes Credit 1 1 No Credit 2 1 Yes Credit 3.1 1 Yes Credit 3.2 1 Yes Credit 4.1 1 Yes Credit 4.2 1 Yes Credit 4.3 1 Yes Credit 4.4 1 Yes Credit 5 1 Yes Credit 6.1 1 No Credit 6.2 1 Yes Credit 7.1 1 No Credit 7.2 1 No Credit 8.1 1 No Credit 8.2 1

4 Possible Points 6 Yes Credit 1.1 Innovation in Design 1.1 1

Select if ID 1.1 was for energy and/or water Yes Credit 1.2 Innovation in Design 1.2 1

Select if ID 1.2 was for energy and/or water Yes Credit 1.3 Innovation in Design 1.3 1

Select if ID 1.3 was for energy and/or water No Credit 1.4 Innovation in Design 1.4 1

Select if ID 1.4 was for energy and/or water No Credit 1.5 Innovation in Design 1.5 1

Select if ID 1.5 was for energy and/or water Yes Credit 2 LEED® Accredited Professional 1

4 Possible Points 4 Yes Credit 1.1 Regional Priority 1.1 1

Select if RP 1.1 was for energy and/or water Yes Credit 1.2 Regional Priority 1.2 1

Select if RP 1.2 was for energy and/or water Yes Credit 1.3 Regional Priority 1.3 1

Select if RP 1.3 was for energy and/or water Yes Credit 1.4 Regional Priority 1.4 1

Select if RP 1.4 was for energy and/or water Possible Points 110

49 Total LEED® Yes Points 0 Total LEED® Maybe Points

19 Total LEED® No Points 13 Total LEED® Energy and Water Related Points

Certified LEED® Certification Status

N/A LEED® Horizontal Benchmark Level Horizontal N/A

N/A LEED® Utility Benchmark Level Utilities N/A

N/A LEED® Industrial Benchmark Level Industrial N/A

LEED®: Certified: 40-49 points, Silver: 50-59 points, Gold: 60-79 points, Platinum: 80-110

Outside Air Delivery Monitoring

Low Emitting Materials, Flooring Systems (HPSB GP4) Low Emitting Materials, Composite Wood & Agrifiber Products (HPSB GP4)

Construction IAQ Management Plan, During Construction (HPSB GP4) Construction IAQ Management Plan, Before Occupancy (HPSB GP4) Low Emitting Materials, Adhesives & Sealants (HPSB GP4) Low Emitting Materials, Paints & Coatings (HPSB GP4)

Increased Ventilation

Daylight & Views - Views for 90% of Spaces

Controllability of Systems, Thermal Comfort Thermal Comfort, Design (HPSB GP4)

Indoor Chemical & Pollutant Source Control Controllability of Systems, Lighting (HPSB GP4)

Thermal Comfort, Verification Daylight & Views - Daylight 75% of Spaces (HPSB GP4)

Certified Wood (HPSB GP5) Rapidly Renewable Materials (HPSB GP5)

Recycled Content

Building Reuse - Maintain 50% of Interior Non-Structural Elements

Attachment 2 v2015(1) - 4

File details come from the government source that posted it.