W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part3.pdf

PDF 17 MB Posted

Attached to
Spinal Cord Injury and Community Living Center (SCI/CLC) Building and Parking Structure, Veterans' Affairs Healthcare System, San Diego, California
Solicitation number
W912PL-20-R-0004
Issued by

About this file

This notice announces a competitive solicitation for construction services. The Department of the Army Corps of Engineers will solicit proposals for the construction of a new Spinal Cord Injury and Community Living Center building and associated parking structure at the Veterans Affairs campus in San Diego, California. Work includes construction of a 197,000 square foot expansion building with 50 SCI beds and 33 CLC beds, along with outpatient clinics, therapy spaces, and site work. An 800-space parking structure will also be built. The estimated cost range is $100-250 million. The solicitation will be available on October 31st with proposals due January 21st. This will result in a firm fixed-price contract with a performance period of three years from notice to proceed. The project is subject to HUBZone price evaluation preference and must follow mission critical security standards.

Plans - SCICLC - Volume 2A Part 3

View the file

Other files

File Type Posted
W912PL-20-R-0004_Amendment0012.pdf PDF
W912PL-20-R-0004 Amendment 0011.pdf PDF
W912PL-20-R-0004_Amendment0010.pdf PDF
W912PL-20-R-0004 Amendment 0009.pdf PDF
W912PL20R0004_Amendment0008.pdf PDF
J and A Sole Source redacted Edwards EST3.pdf PDF
J and A Sole Source redacted Schlage Primus.pdf PDF
W912PL-20-R-0004 Amendment 0007.pdf PDF
W912PL20R0004_Amendment0006.pdf PDF
W912PL-20-R-0004_Amendment0005.pdf PDF
W912PLR0004_Amendment0004.pdf PDF
W912PL-20-R-0004_Amendment0003.pdf PDF
W912PL-20-R-0004_Amendment0002.pdf PDF
Sign-In Roster_SiteWalk_VA SD_2019.11.21.pdf PDF
W912PL20R0004 SF-1442_Amend0001 .pdf PDF
W912PL20R0004 SF-30_Amend0001.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part3.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL3_ParkingGarage.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2B.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part2.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL4_Appendices.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL2_SCICLC1TO4of4.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL1_SCI-CLCandParkingGarage.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL3..pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2H.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL2..pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2E.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part4.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2D.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part1.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

U

A

A

F

N

G

P

PART B - SEE DRAWING AE113B

PART C - SEE DRAWING AE113C

PART D - SEE DRAWING AE113D

PART A - SEE DRAWING AE113A

EXISTING BUILDING 11

EXISTING BUILDING 11

A

C

D

B

N

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:3

:5

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

THIRD FLOOR REFLECTED CEILING

PLAN

AE113

664-401

07/19/2019 AB/JT

SCALE: 1/16" = 1'-0"

THIRD FLOOR REFLECTED CEILING PLAN

KEY PLAN

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

DAVID HUNT

Solicitation Number: W912PL20R0004

A

C

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

U

U

N

P

NO CEILING

NO CEILING

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

9' - 2"

AT-3

9' - 0"

AT-1

9' - 0"

AT-7

8' - 0"

RESIDENT

ROOM

3A115

RESIDENT

ROOM

ISOLATION

ANTE ROOM

3A115B

ISOLATION

ANTE ROOM

PSYC.

OFFICE

3A131

PSYC.

OFFICE

PSYC.

OFFICE

3A130

PSYC.

OFFICE

PSYC.

OFFICE

3A129

PSYC.

OFFICE

SHARED

OFFICE

3A125

SHARED

OFFICE

OFFICE

3A126

OFFICE

EDUCATION

3A133

EDUCATION

PHYSICIAN

OFFICE

3A127

PHYSICIAN

OFFICE

PHYSICIAN

OFFICE

3A128

PHYSICIAN

OFFICE

STAIR 1

3A21

STAIR 1

COPY ROOM

3A134

COPY ROOM

DIETITIAN

OFFICE

3A135

DIETITIAN

OFFICE

STAFF

LOCKERS

3A105A

STAFF

LOCKERS

MEDICAL

EQUIPMENT

STORAGE

3A147

MEDICAL

EQUIPMENT

STORAGE

NURSE

STATION

3A148

NURSE

STATION

ELECTRICAL

3A139

ELECTRICAL

OFFICE

3A140

OFFICE

NOURISHMENT

KITCHEN

3A145

NOURISHMENT

KITCHENCLEAN

UTILITY

3A146

CLEAN

UTILITY

BARIATRIC

RESIDENT

BATHROOM

3A109A

BARIATRIC

RESIDENT

BATHROOM

BARIATRIC

RESIDENT

ROOM

3A109

BARIATRIC

RESIDENT

ROOM

RESIDENT

ROOM

3A111

RESIDENT

ROOM

HALLWAY

3A110

HALLWAY

SHAFT 2

3A136B

SHAFT 2

SHAFT 1

3A21B

SHAFT 1

PART B

SEE DRAWING AE113B

SCS-3

12' - 4"

AE603TYP.

AE603

8' - 0"

AE113A

TYP.

AE467

AE602

F

AE114C

SIM.

AE114C

SIM.

9' - 8" 9' - 8" 9' - 8" 9' - 7" 3' - 5"

2' - 8"

JANITOR

3A107

JANITOR

EQUIPMENT

STORAGE

3A108

EQUIPMENT

STORAGE

RESIDENT

ROOM

3A116

RESIDENT

ROOM

AT-1

9' - 2"

AT-1

9' - 2"

RESIDENT

ROOM

3A118

RESIDENT

ROOM

SCS-2

9' - 0"

SCS-2

9' - 0"

RESIDENT

BATHROOM

3A119A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3A118A

RESIDENT

BATHROOM

RESIDENT

ROOM

3A119

RESIDENT

ROOM

RESIDENT

ROOM

3A120

RESIDENT

ROOM

HALLWAY

3A112

HALLWAY

SHAFT 3

2A104B

SHAFT 3

RESIDENT

BATHROOM

3A122A

RESIDENT

BATHROOM

RESIDENT

ROOM

3A122

RESIDENT

ROOM

RESIDENT

ROOM

3A121

RESIDENT

ROOM

RESIDENT

BATHROOM

3A121A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3A120A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3A115A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3A116A

RESIDENT

BATHROOM

RESIDENT

ROOM

3A123

RESIDENT

ROOM

RESIDENT

BATHROOM

3A123A

RESIDENT

BATHROOM

STAFF

LOUNGE

3A132

STAFF

LOUNGE

CHARTING

3A136

CHARTING

MEDICATION

3A149

MEDICATION

SOILED

UTILITY

3A150

SOILED

UTILITY

HALLWAY

3A124

HALLWAY

SUB NS STN

3A151

SUB NS STN

RESIDENT

BATHROOM

3A111A

RESIDENT

BATHROOM

DAY ROOM

LIVING

ROOM

3A144

DAY ROOM

LIVING

ROOM

PANTRY

3A145A

PANTRY

GARDEN

TERRACE

3A113

GARDEN

TERRACE

SUB NS STN

3A142

SUB NS STN

OFFICE

3A141

OFFICE

HALLWAY

3A114

HALLWAY

IDF

3A104

IDF

STAFF

SHOWER &

TOILET

3A105B

STAFF

SHOWER &

TOILET

WARD

CLERK

3A137

WARD

CLERK

HALLWAY

3A138

HALLWAY

ACTIVITY

ROOM

3A143

ACTIVITY

ROOM

HALLWAY

3A117

HALLWAY

ALCOVE

3A105

ALCOVE

HALLWAY

3A103

HALLWAY

HALLWAY

3A106

HALLWAY

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

SCS-1

13' - 0"

SCS-2

9' - 0"

AT-1

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0" AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

SCS-1

8' - 6"

SCS-1

8' - 0"

SCS-1

8' - 0"

SCS-1

9' - 0"

SCS-1

8' - 0"

AT-1

9' - 0"

AT-2

9' - 0"

AT-2

9' - 0"

AT-2

9' - 0"

SCS-1

9' - 0"

AT-1

8' - 6"

SCS-1

8' - 6"

SCS-1

8' - 0"

7' - 0"

7' - 0"

AT-1

9' - 2"

7' - 0"

SCS-2

9' - 0"

AE312

1 HR SHAFT CLG

ABOVE FINISH

CLG ENTIRE

ROOM

SCS-1

8' - 0"

SCS-1

8' - 6"

SCS-1

8' - 6"

NO CEILING

2' X 2' CLG.

ACCESS

PANEL

TYP.13

AE603

PATIENT LIFT PER

AQ SHEETS, DETAIL

PER 1/SJ801

CURTAIN TRACK

PER IN SHEETS

LIGHT FIXTURE PER

ELEC. SHEETS

SUPPLY REGISTER

PER MECH. SHEETS

FIRE SPRINKLER

HEAD PER FX SHEETS

EXAM LIGHT

FIXTURE PER

ELEC. SHEETS

TYP.

2' - 0"

10' - 4"

SCS-2

7' - 0"

SCS-2

9' - 0"

RESIDENT

BATHROOM

3A116A

RESIDENT

BATHROOM

RESIDENT

ROOM

3A116

RESIDENT

ROOM

AT-1

9' - 2"

9' - 2"

E Q

E Q

3'

0"

SHOWER

CURTAIN PER

AE453

MIRROR PER

AE453

ROLLER SHADE

SCREEN, O.F.C.I.,

PER IN SHEETS

EQ.EQ.

EQ. EQ.

E Q

E

Q

LIGHT FIXTURE PER

ELECTRICAL

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:1

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED THIRD FLOOR RCP - PART

A

AE113A

664-401

07/19/2019 AB/JT

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDREFLECTED CEILING PLAN LEGEND

SCALE: 1/8" = 1'-0"

THIRD FLOOR REFLECTED CEILING PLAN - PART A

SCALE: 3/16" = 1'-0"

CLC PATIENT ROOM & TOILET RCP - TYPICAL

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

F

AT-1

10' - 0"

RESIDENT

DINING

3B134

RESIDENT

DINING

SERVICE

ELEVATOR

LOBBY

3B133

SERVICE

ELEVATOR

LOBBY

ELEVATOR

LOBBY

3A101

ELEVATOR

LOBBY

OPEN TO

BELOW

OPEN TO

BELOW

BALCONY

3A102

BALCONY

PASSENGER

ELEVATOR

3AP2

PASSENGER

ELEVATOR

PART A

SEE DRAWING AE113A

SERVICE

ELEVATOR

3AS1

SERVICE

ELEVATOR

SERVICE

ELEVATOR

3AS2

SERVICE

ELEVATOR

PASSENGER

ELEVATOR

3AP1

PASSENGER

ELEVATOR

SCS-1

9' - 0"

AT-2

9' - 0"

PASSENGER

ELEVATOR

3AP3

PASSENGER

ELEVATOR

PASSENGER

ELEVATOR

3AP4

PASSENGER

ELEVATOR

AE712

2' X 3' SMOKE

CURTAIN

ACCESS PANEL

ALIGN

PART C

SEE DRAWING AE113C

08 34 86.A1

08 34 86.A2

AE111B

SCS-3

12' - 4"

GARDEN

TERRACE

GARDEN

TERRACE

9' - 0". 4"

REFER TO

HALLWAY

1A125 FOR

LIGHTING

LAYOUT

SCS-1

11' - 0"

SCS-1

11' - 0"

PANTRY

3B134A

PANTRY

HALLWAY

3B132

HALLWAY

AT-1

9' - 0"

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:5

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED THIRD FLOOR RCP - PART

B

AE113B

664-401

07/19/2019 AB/JT

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDREFLECTED CEILING PLAN LEGEND

KEY VALUE KEYNOTE TEXT

08 34 86.A1 1 HOUR SMOKE RATED CURTAIN – OPENING 6 – 12 FEET WIDE

08 34 86.A2 1 HOUR SMOKE RATED CURTAIN – OPENING 12 – 20 FEET WIDE

SCALE: 1/8" = 1'-0"

NEW WORK THIRD FLOOR RCP - PART B

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

A

A

F

G

7 8

AT-1

9' - 2"

AT-1

9' - 2"

SCS-2

9' - 0"

AT-7

8' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

8' - 0"

AT-7

8' - 0"

8' - 0"

AT-1

9' - 2"

AT-1

9' - 2"

SCS-2

9' - 0"

AT-1

9' - 2"

8' - 0"

8' - 0"

AT-7

8' - 0"

8' - 0"

8' - 0"

SCS-2

9' - 0"

AT-3

9' - 0"

RESIDENT

ROOM

3B123

RESIDENT

ROOM

STAIR 2

3B06

STAIR 2

PT ROOM

3B130

PT ROOM

RESIDENT

BATHROOM

3B129A

RESIDENT

BATHROOM

RESIDENT

ROOM

3B129

RESIDENT

ROOM

RESIDENT

ROOM

3B128

RESIDENT

ROOM

RESIDENT

BATHROOM

3B128A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3B127A

RESIDENT

BATHROOM

RESIDENT

ROOM

3B127

RESIDENT

ROOM

RESIDENT

BATHROOM

3B123A

RESIDENT

BATHROOM

RESIDENT

ROOM

3B122

RESIDENT

ROOM

SOILED

LINEN

3B145

SOILED

LINEN

PUBLIC

TOILET

3B143

PUBLIC

TOILET

PATIENT

LAUNDRY

3B153

PATIENT

LAUNDRY

ELECTRICAL

3B142

ELECTRICAL

SOILED

UTILITY

3B141

SOILED

UTILITY

THERAPY

REC. OFFICE

3B140

THERAPY

REC. OFFICE

CLEAN

UTILITY

3B155

CLEAN

UTILITY

NURSE

SUPERVISOR

3B156

NURSE

SUPERVISOR

STAIR 3

3B71

STAIR 3

WARD

CLERK

3B158

WARD

CLERK

SOCIAL

WORK

OFFICE

3B117

SOCIAL

WORK

OFFICE

NURSE

OFFICE

3B113

NURSE

OFFICE

OFFICE

3B136

OFFICE

SCI NURSE

ADMIN

3B110

SCI NURSE

ADMIN

ANNUAL

EVAL

RESIDENT

ROOM

3B104

ANNUAL

EVAL

RESIDENT

ROOM

RESIDENT

BATHROOM

3B104A

RESIDENT

BATHROOM

ANNUAL

EVAL

RESIDENT

ROOM

3B101

ANNUAL

EVAL

RESIDENT

ROOM

RESIDENT

BATHROOM

3B100A

RESIDENT

BATHROOM

SMOKE

EVACUATION

& STEAM

SHAFT 4

3B05B

SMOKE

EVACUATION

& STEAM

SHAFT 4

OFFICE

3B154

OFFICE

STAFF

TOILET

3B144

STAFF

TOILET

CLEAN

LINEN

3B146

CLEAN

LINEN

NO CEILING

PART B

SEE DRAWING AE113B

13' - 0"

WP-4

8' - 0"

RECYCLING

COLLECTION

3A168

RECYCLING

COLLECTION

AT-2

9' - 0"

8' - 0"

SHAFT 6

2B136B

SHAFT 6

8' - 0"

AT-1

9' - 2"

WP-4

8' - 0"

SCS-1

8' - 6"

SCS-1

8' - 6"

PART D

SEE DRAWING AE113D

AE466

SCS-3

12' - 4"

GARDEN

TERRACE

GARDEN

TERRACE

AT-1

9' - 0"

ANNUAL

EVAL

RESIDENT

ROOM

3B100

ANNUAL

EVAL

RESIDENT

ROOM

AT-1

9' - 2"

4"

AT-1

8' - 0"

SCS-1

9' - 0"

8"ALIGN

4' - 0"

EQ.

EQ.

AE113C

4' - 0"

IDF

3B131

IDF

AT-2

9' - 0"

4' - 0"

4'

0" 4'

0"

6' - 0"

A

LI

G N

4'

0"

1'

1/

4" 4'

0"

4'

0" 4'

0"

4'

0" 4'

0"

4'

0" 4'

0"

4'

0" 4'

0"

4'

0" 4'

0"

1'

3/

4"

3' - 0" 4' - 0"

AE305

SCS-1

13' - 0"

AE604

COVE LIGHT

PER ELEC.

SHEETS

AE571

16.1

AT-1

9' - 2"

SCS-2

9' - 0"

SCS-2

9' - 0"

AT-1

8' - 0"

PHYSICIAN

OFFICE

3B106

PHYSICIAN

OFFICE

STAFF

TOILET

3B107

STAFF

TOILET

NURSE

SUPERVISOR

3B108

NURSE

SUPERVISOR

CHIEF

OFFICE

3B109

CHIEF

OFFICE

SCI NURSE

ADMIN

3B111

SCI NURSE

ADMIN

EDUCATION

NURSE

OFFICE

3B112

EDUCATION

NURSE

OFFICE OFFICE

3B114

OFFICE

ISOLATION

ANTE ROOM

3B120B

ISOLATION

ANTE ROOM

ISOLATION

RESIDENT

ROOM

3B120

ISOLATION

RESIDENT

ROOM

ISOLATION

RESIDENT

BATHROOM

3B120A

ISOLATION

RESIDENT

BATHROOM

RESIDENT

ROOM

3B121

RESIDENT

ROOM

RESIDENT

BATHROOM

3B121A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3B122A

RESIDENT

BATHROOM

HALLWAY

3B124

HALLWAY

DAY ROOM

LIVING

ROOM

3B148

DAY ROOM

LIVING

ROOM

NOURISHMENT

KITCHEN

3B149

NOURISHMENT

KITCHEN

PANTRY

3B149A

PANTRY

MEDICAL

EQUIPMENT

STORAGE

3B151

MEDICAL

EQUIPMENT

STORAGE

TRANSFER

EQUIP

STORAGE

3B152

TRANSFER

EQUIP

STORAGE

HALLWAY

3B126

HALLWAY

HALLWAY

3B164

HALLWAY

PA OFFICE

3B157

PA OFFICE

SHAFT 5

2B116B

SHAFT 5

PHARMACY

OFFICE

3B159

PHARMACY

OFFICE

MEDICATION

3B160

MEDICATION

STAFF

LOUNGE

3B137

STAFF

LOUNGE

LITTER

(GURNEY)

STORAGE

3B161

LITTER

(GURNEY)

STORAGE

CONFERENCE

ROOM

3B135

CONFERENCE

ROOM

RESIDENT

BATHROOM

3B101A

RESIDENT

BATHROOM

HALLWAY

3B105

HALLWAY

HALLWAY

3B115

HALLWAY

HALLWAY

3B115

HALLWAY

HALLWAY

3B119

HALLWAY

HALLWAY

3B125

HALLWAY

SCS-2

9' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

SOCIAL

WORK

OFFICE

3B118

SOCIAL

WORK

OFFICE

HALLWAY

3B139

HALLWAY

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

9' - 2" 8' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

AT-2

9' - 0"

AT-3

8' - 0"

SCS-1

8' - 6"

AT-2

9' - 0"

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"8' - 0"

AT-1

8' - 6"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-8

9' - 0"

NURSE

STATION

3B138

NURSE

STATION

AT-1

9' - 2"

WHEELCHAIR/STRETCHER

3B162

WHEELCHAIR/STRETCHER

SCS-1

8' - 6"

SCS-1

9' - 0"

SCS-1

8' - 6"

NO CEILING

2' X 2' CLG.

ACCESS

PANEL

RESIDENT

BATHROOM

3B129A

RESIDENT

BATHROOM

RESIDENT

ROOM

3B129

RESIDENT

ROOM

SCS-2

9' - 0"

AT-1

9' - 2"

CURTAIN TRACK

PER IN SHEETS

PATIENT LIFT TRACK

PER AQ SHEETS,

DETAIL PER 1/SJ801

SCS-2

7' - 0"

ROLLER SHADE

SCREEN, O.F.C.I.,

PER IN SHEETS

AE603

TYP.

EXAM LIGHT FIXTURE

PER ELEC. SHEETS

LIGHT FIXTURE PER

ELEC. SHEETS

10' - 4"9' - 2"

FIRE SPRINKLER HEAD

PER FX SHEETS

SUPPLY REGISTER

PER MECH. SHEETS

E Q

E Q

TYP.

2' - 0"

3'

0"

.EQ.EQ.

SHOWER

CURTAIN PER

AE453

MIRROR PER

AE453

EQ.EQ.E

Q

E

Q

LIGHT FIXTURE

REFER TO ELECTRICAL

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:2

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED THIRD FLOOR RCP - PART

C

AE113C

664-401

07/19/2019 AB/JT

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDREFLECTED CEILING PLAN LEGEND

SCALE: 1/8" = 1'-0"

NEW WORK THIRD FLOOR RCP - PART C

SCALE: 3/16" = 1'-0"

RESIDENT ROOM & TOILET RCP - TYPICAL

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

A

CF

AE305

AE305

AE305

AE305

PART C

SEE DRAWING AE113C

TYP.

AE325

AE325

STRUCTURAL BEAMS AND COLUMNS,

PT. PER STRUCT. SHEETS

TRANSLUCENT ROOFING

AE305

AE305

5.1. 6.

Q.Q.

5.0

EXISTING BUILDING 11

EXISTING BUILDING 11

A

C

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:4

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED THIRD FLOOR RCP - PART

D

AE113D

664-401

07/19/2019 AB/JT

SCALE: 1/8" = 1'-0"

A1

NEW WORK THIRD FLOOR RCP - PART D

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDREFLECTED CEILING PLAN LEGEND

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

A

A

F

N

G

P

1/

2"

1' - 0"

PART B - SEE DRAWING AE114B

PART C - SEE DRAWING AE114C

PART A - SEE DRAWING AE114A

A

C

D

B

N

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:5

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

FOURTH FLOOR REFLECTED CEILING

PLAN

AE114

664-401

07/19/2019 AB/JT

SCALE: 1/16" = 1'-0"

FOURTH FLOOR REFLECTED CEILING PLAN

KEY PLAN

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

U

N

P

NO CEILING

9' - 0"

SCS-2

9' - 0"

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-1

9' - 0"

8' - 0"

AT-1

8' - 0"

SCS-2

9' - 0"

AT-1

10' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

AT-7

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-2

9' - 0"

AT-8

9' - 0"

AT-3

9' - 0"

AT-1

9' - 2" 9' - 2"

AT-1

9' - 2"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

10' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2" 9' - 2"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0" 9' - 0"

10' - 2"

AT-1

8' - 0"

AT-1

9' - 0"

10' - 2"

10' - 2"

10' - 4" 10' - 4"

10' - 2"

10' - 2"

10' - 2"

10' - 2" 10' - 2"

10' - 2"

10' - 2" 10' - 2"

10' - 2"

10' - 2"

STORAGE

EQUIPMENT

4A111

STORAGE

EQUIPMENT

HOUSE

CARE

4A112

HOUSE

CARE

MEDICATION

4A112A

MEDICATION

NURSE

SUPERVISOR

4A113A

NURSE

SUPERVISOR

HALLWAY

4A113

HALLWAY

RESIDENT

ROOM

4A114

RESIDENT

ROOM

RESIDENT

BATHROOM

4A114A

RESIDENT

BATHROOM

ACTIVITY

ROOM

4A119

ACTIVITY

ROOM

DINING

4A118

DINING

KITCHEN

4A118A

KITCHEN

PANTRY

4A118B

PANTRY

RESIDENT

ROOM

4A115

RESIDENT

ROOM

RESIDENT

BATHROOM

4A115A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4A116A

RESIDENT

BATHROOM

HALLWAY

4A122

HALLWAY

RESIDENT

ROOM

4A123

RESIDENT

ROOM

RESIDENT

BATHROOM

4A123A

RESIDENT

BATHROOM

RESIDENT

ROOM

4A124

RESIDENT

ROOM

RESIDENT

BATHROOM

4A124A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4A125A

RESIDENT

BATHROOM

RESIDENT

ROOM

4A125

RESIDENT

ROOM

RESIDENT

ROOM

4A127

RESIDENT

ROOM

RESIDENT

BATHROOM

4A127A

RESIDENT

BATHROOM

LAUNDRY

4A128

LAUNDRY

RESIDENT

ROOM

4A129

RESIDENT

ROOM

RESIDENT

BATHROOM

4A129A

RESIDENT

BATHROOM

MEDICAL

EQUIPMENT

STORAGE

4A133

MEDICAL

EQUIPMENT

STORAGE

RESIDENT

ROOM

4A130

RESIDENT

ROOM

RESIDENT

BATHROOM

4A130A

RESIDENT

BATHROOM

HALLWAY

4A139

HALLWAY

IDF

4A109

IDF

SOILED

UTILITY

4A142

SOILED

UTILITY

ELECTRICAL

4A143

ELECTRICAL

CLEAN

UTILITY

4A141

CLEAN

UTILITY

RESIDENT

ROOM

4A131

RESIDENT

ROOM

RESIDENT

BATHROOM

4A131A

RESIDENT

BATHROOM

DEN

4A136

DEN

RESIDENT

ROOM

4A137

RESIDENT

ROOM

RESIDENT

BATHROOM

4A137A

RESIDENT

BATHROOM

RESIDENT

TOILET

4A135

RESIDENT

TOILET

HAC

4A134

HAC

STAFF

TOILET

4A140

STAFF

TOILET

MEDITATION

'QUIET'

ROOM

4A105

MEDITATION

'QUIET'

ROOM

VISITOR

TOILET

4A106

VISITOR

TOILET

VISITOR

TOILET

4A107

VISITOR

TOILET

MEDITATION/

COUNSELING

4A104

MEDITATION/

COUNSELING

MULTIDISCIP.

OFFICE

4A147

MULTIDISCIP.

OFFICE

HALLWAY

4A165

HALLWAY

ACTIVITIES

COORDINATOR

4A167

ACTIVITIES

COORDINATOR

HALLWAY

4A158

HALLWAY

SOCIAL

WORK

OFFICE

4A166

SOCIAL

WORK

OFFICE

RECREATIONAL

THERAPIST

OFFICE

4A148

RECREATIONAL

THERAPIST

OFFICE

MULTIDISCIP.

OFFICE

4A149

MULTIDISCIP.

OFFICE

PHARMACY

OFFICE

4A151

PHARMACY

OFFICE

COPY ROOM

4A150

COPY ROOM

POD

LEADER

OFFICE

4A152

POD

LEADER

OFFICE

CLERICAL

4A156A

CLERICAL

CLERICAL

4A156B

CLERICAL

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

4A154

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

HALLWAY

4A146

HALLWAY

HALLWAY

4A156

HALLWAY

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

4A155

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

4A157

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

MED.

DIRECTOR'S

OFFICE

4A160

MED.

DIRECTOR'S

OFFICE

MULTIDISCIP.

OFFICE

4A161

MULTIDISCIP.

OFFICE

CONFERENCE

ROOM

4A163

CONFERENCE

ROOM

STAFF

LOUNGE

4A164

STAFF

LOUNGE

WHEELCHAIR

STORAGE

4A110

WHEELCHAIR

STORAGE

PHYSICAL

THERAPY

STORAGE

4A176

PHYSICAL

THERAPY

STORAGE

SOILED

LINEN

4A176A

SOILED

LINEN

CLEAN

LINEN

STORAGE

4A176B

CLEAN

LINEN

STORAGE

STAFF

TOILET

4A162

STAFF

TOILET

STAIR 1

4A21

STAIR 1

SOUTH

TERRACE

SOUTH

TERRACE

SHAFT 2

4A143B

SHAFT 2

SHAFT 1

SHAFT 1

OCCUPATIONAL

THERAPY

4A175D

OCCUPATIONAL

THERAPY

HALLWAY

4A103

HALLWAY

10' - 2"

SCS-1

8' - 6"

SERVICE

CHIEF

OFFICE

4A153

SERVICE

CHIEF

OFFICE

PART B

SEE DRAWING AE114B

AT-1

8' - 0"

10' - 2"

AT-1

9' - 0"

AT-3

9' - 0"

AT-1

8' - 0"

AT-8

9' - 0"

8' - 0"

RESIDENT

ROOM

4A116

RESIDENT

ROOM

SCS-1

8' - 6"

PASSENGER

ELEVATOR

4AP4

PASSENGER

ELEVATOR PASSENGER

ELEVATOR

4AP3

PASSENGER

ELEVATOR

HALLWAY

4A108

HALLWAY

SCS-1

9' - 0"

8' - 0"

8' - 0"

AE465

AE603

AE603

AE603

AE603

AE603

AE603

AE603

AE603

AE467

SCS-1

8' - 6"

AT-1

8' - 0"

SCS-3

12' - 4"

SCS-3

12' - 4"

AT-8

9' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-7

8' - 0"

8' - 0"

8' - 0"

8' - 0" 8' - 0"

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

8' - 6"

AE114C

AE114C

SIM.

12' - 8"

SCS-1

11' - 0"

NO CEILING

6'

0" 4"

4'

6"

4'

0"

4' - 0" 6' - 4".

6' - 0" 4 "

2' -10".

8"

E Q

10' - 0 ".

1 0' - 0 ".

E

Q

ALIGN

ALIGN

4' - 0"

HALLWAY

4A132

HALLWAY

SCS-1

13' - 0"

GARDEN

TERRACE

GARDEN

TERRACE

4" 8' - 10" 4"

AE114A

NO CEILING

2' x 2' CLG.

ACCESS

PANEL

A

C

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

10' - 4"

7' - 3"

SCS-2

9' - 0"

9' - 2"

AT-1

9' - 2"

RESIDENT

ROOM

4A127

RESIDENT

ROOM

RESIDENT

BATHROOM

4A127A

RESIDENT

BATHROOM

CURTAIN TRACK

PER IN SHEETS

FIRE SPRINKLER

HEAD PER FX

SHEETS

SUPPLY REGISTER

PER M SHEETS

LIGHT FIXTURE PER

E SHEETS

AE602

F

EXAM LIGHT PER

E SHEETS

AE603

TYP.

EQ.EQ.

E Q

E

Q

E Q

E

Q

PATIENT LIFT PER

AQ SHEETS, DETAIL

PER 1/SJ801

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:1

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED FOURTH FLOOR RCP -

PART A

AE114A

664-401

07/19/2019 AB/JT

SCALE: 1/8" = 1'-0"

FOURTH FLOOR REFLECTED CEILING PLAN - SOUTH

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDREFLECTED CEILING PLAN LEGEND

SCALE: 3/16" = 1'-0"

CLC RESIDENT ROOM & TOILET RCP - TYPICAL

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

F

2 7

P

DAY ROOM

4A174

DAY ROOM

SERVICE

ELEVATOR

LOBBY

4A171

SERVICE

ELEVATOR

LOBBY

PASSENGER

ELEVATOR

4AP2

PASSENGER

ELEVATOR

WARMING

KITCHEN

4A174C

WARMING

KITCHEN

OCCUPATIONAL

THERAPY

4A175D

OCCUPATIONAL

THERAPY

PHYSICAL

THERAPY

4A175A

PHYSICAL

THERAPY

REHABILITATION

THERAPIST

4A175B

REHABILITATION

THERAPIST

PART C

SEE DRAWING AE114C

PART A

SEE DRAWING AE114A

12' - 4"

SERVICE

ELEVATOR

4AS1

SERVICE

ELEVATOR

SERVICE

ELEVATOR

4AS2

SERVICE

ELEVATOR

PASSENGER

ELEVATOR

4AP1

PASSENGER

ELEVATOR

PASSENGER

ELEVATOR

4AP4

PASSENGER

ELEVATOR PASSENGER

ELEVATOR

4AP3

PASSENGER

ELEVATOR

ELEVATOR

LOBBY

4A101

ELEVATOR

LOBBY

OCCUPATIONAL

THERAPIST

4A175C

OCCUPATIONAL

THERAPIST

8' - 0"

8' - 0"

SCS-1

8' - 6"

AE712

2' X 3' SMOKE

CURTAIN ACCESS

PANEL

AT-1

10' - 0"

AT-2

9' - 0"

SCS-1

9' - 0"

PHYSICAL

THERAPY

4A175

PHYSICAL

THERAPY

9' - 0"

BALCONY

4A102

BALCONY

SCS-1

11' - 0"

AE111B

08 34 86.A2

08 34 86.A1

EXTERIOR

SOFFIT

VENDING

AREA

4A170A

VENDING

AREA

NO CEILING

REFER TO

HALLWAY

1A125 FOR

LIGHTING

LAYOUT

AT-1

10' - 0"

16.1

4" 8' - 10" 4"

NO CEILING

2' x 2' CLG.

ACCESS

PANEL

A

C

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:3

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED FOURTH FLOOR RCP -

PART B

AE114B

664-401

07/19/2019 AB/JT

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGEND

SCALE: 1/8" = 1'-0"

FOURTH FLOOR REFLECTED CEILING PLAN - SOUTH

REFLECTED CEILING PLAN LEGEND

KEY VALUE KEYNOTE TEXT

08 34 86.A1 1 HOUR SMOKE RATED CURTAIN – OPENING 6 – 12 FEET WIDE

08 34 86.A2 1 HOUR SMOKE RATED CURTAIN – OPENING 12 – 20 FEET WIDE

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

A

A

F

G

SCS-2

9' - 0"

8' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

9' - 0"

SCS-2

8' - 0"

10' - 4"

AT-6

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

7' - 3"

AT-1

9' - 2"

AT-1

9' - 2"

7' - 3"

10' - 4"

AT-1

9' - 2"

AT-6

9' - 2"

AT-6

9' - 2"

SCS-2

9' - 0"

AT-6

8' - 0"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-6

9' - 2"

AT-6

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-6

8' - 0"

10' - 4"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

AT-1

9' - 2"

8' - 2 1/2"

SCS-1

8' - 6"

ALCOVE

4B122A

ALCOVE

RECYCLING

COLLECTION

4A172

RECYCLING

COLLECTION

IDF

4B173

IDF

HALLWAY

4B160

HALLWAY

VISITOR

LOUNGE

4B162

VISITOR

LOUNGE

PATIENT

TOILET

4B164

PATIENT

TOILET

CLEAN

LINEN &

HOUSEKEEPING

4B125

CLEAN

LINEN &

HOUSEKEEPING

BARBER /

BEAUTY

SHOP

4B161

BARBER /

BEAUTY

SHOP

RESIDENT

ROOM

4B157

RESIDENT

ROOM

NURSE

SUPERVISOR

4B158

NURSE

SUPERVISOR

RESIDENT

BATHROOM

4B157A

RESIDENT

BATHROOM

HOUSE

CARE

4B137A

HOUSE

CARE

MEDICATION

4B138

MEDICATION

RESIDENT

ROOM

4B156

RESIDENT

ROOM

RESIDENT

BATHROOM

4B156A

RESIDENT

BATHROOM

HALLWAY

4B137

HALLWAY

RESIDENT

ROOM

4B155

RESIDENT

ROOM

RESIDENT

BATHROOM

4B155A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B153

RESIDENT

ROOM

RESIDENT

BATHROOM

4B153A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B152

RESIDENT

ROOM

RESIDENT

BATHROOM

4B151A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B152A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B151

RESIDENT

ROOM

RESIDENT

ROOM

4B147

RESIDENT

ROOM

RESIDENT

BATHROOM

4B147A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B143A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B142

RESIDENT

ROOM

RESIDENT

BATHROOM

4B136A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B142A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B136

RESIDENT

ROOM

ISOLATION

RESIDENT

ROOM

4B135

ISOLATION

RESIDENT

ROOM

ISO.

RESIDENT

TOILET

4B135A

ISO.

RESIDENT

TOILET

ANTE

4B135B

ANTE

BARIATRIC

BEDROOM

4B132

BARIATRIC

BEDROOM

BARIATRIC

BATHROOM

4B132A

BARIATRIC

BATHROOM

STAIR 3

4B71

STAIR 3

HAC

4B126

HAC

MEDICAL

EQUIPMENT

STORAGE

4B127

MEDICAL

EQUIPMENT

STORAGE

SOILED

UTILITY

4B128

SOILED

UTILITY

CLEAN

UTILITY

4B129

CLEAN

UTILITY

ELECTRICAL

4B131

ELECTRICAL

STORAGE

EQUIPMENT

4B139

STORAGE

EQUIPMENT

ACTIVITY

ROOM

4B145

ACTIVITY

ROOMLAUNDRY

4B133

LAUNDRY

RESIDENT

BATHROOM

4B124A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B123A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B123

RESIDENT

ROOM

RESIDENT

ROOM

4B120

RESIDENT

ROOM

RESIDENT

BATHROOM

4B120A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B119

RESIDENT

ROOM

RESIDENT

BATHROOM

4B119A

RESIDENT

BATHROOM

LIVING

ROOM

4B146

LIVING

ROOM

DINING

4B144

DINING

KITCHEN

4B144A

KITCHEN

HALLWAY

4B141

HALLWAY

RESIDENT

ROOM

4B118

RESIDENT

ROOM

RESIDENT

BATHROOM

4B118A

RESIDENT

BATHROOM

BARIATRIC

BATHROOM

4B111A

BARIATRIC

BATHROOM

HAC

4B134

HAC

HALLWAY

4B130

HALLWAY

HALLWAY

4B122

HALLWAY

HALLWAY

4B117

HALLWAY

LIVING

ROOM

4B115

LIVING

ROOM

DINING

4B116

DINING

KITCHEN

4B116A

KITCHEN

HALLWAY

4B110

HALLWAY

HALLWAY

4B107

HALLWAY

ISO.

PATIENT

TOILET

4B109A

ISO.

PATIENT

TOILET

ANTE

4B109B

ANTE

RESIDENT

ROOM

4B108

RESIDENT

ROOM

RESIDENT

ROOM

4B102

RESIDENT

ROOM

HOUSE

CARE

4B104

HOUSE

CARE

MEDICATION

4B106

MEDICATION

NURSE

SUPERVISOR

4B105

NURSE

SUPERVISOR

RESIDENT

ROOM

4B101

RESIDENT

ROOM

RESIDENT

BATHROOM

4B101A

RESIDENT

BATHROOM

STAFF

TOILET

4B100

STAFF

TOILET

RESIDENT

BATHROOM

4B108A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B102A

RESIDENT

BATHROOM

GARDEN

TERRACE

GARDEN

TERRACE

GARDEN

TERRACE

GARDEN

TERRACE

HALLWAY

4B154A

HALLWAY

STORAGE

4A172A

STORAGE

BARIATRIC

BEDROOM

4B111

BARIATRIC

BEDROOM

RESIDENT

ROOM

4B124

RESIDENT

ROOM

SMOKE

EVACUATION

& STEAM

SHAFT

4B04C

SMOKE

EVACUATION

& STEAM

SHAFT

ACTIVITY

ROOM

4B121

ACTIVITY

ROOM

PATIENT

TOILET

4B140

PATIENT

TOILET

NO CEILING

PART B

SEE DRAWING AE114B

RESIDENT

ROOM

4B143

RESIDENT

ROOM

AT-2

9' - 0"

8' - 0"

HALLWAY

4B150

HALLWAY

8' - 0"

9' - 0"

SCS-1

8' - 6"

SCS-1

11' - 0"

AE466

AE465

2' - 3"

AT-3

9' - 0"

AT-8

8' - 0"

8' - 0"

AT-1

8' - 0"

AT-3

9' - 0"

AT-1

8' - 0"

AT-2

9' - 0"

AT-2

9' - 0"

SCS-3

12' - 4"

SCS-3

12' - 4"

SCS-1

8' - 6"

AT-3

9' - 0"

AT-8

9' - 0"

8' - 6"

8' - 2 1/2"

SCS-1

11' - 0"

NO CEILING

4'

0"

8' - 0"

24' - 0"

6'

0" 4"

5'

2"

AT-1

8' - 0"

SHAFT 6

2B136B

SHAFT 6

AT-1

9' - 0"

AE114C

SIM.

AE114C

SIM.

AE114C

SIM.

AE114C

AE114C

SIM.

AE114C

SIM.

2HR

11' - 0"

5' - 2" 6' - 0"

4"

EQ.

EQ.

4'

AE305

AT-7

8' - 0"

AT-1

8' - 0"

AT-1

8' - 0"

AT-1

9' - 0"

SCS-1

8' - 6"

AT-1

9' - 0" 9' - 0"

AT-1

9' - 0"

AT-1

9' - 0"

COVE LIGHT

PER ELEC.

SHEETS

AE604

AE571

8' - 0".

8' - 0".

4' - 0"

4' - 0"

5.1. 6.5.0

AE736

A

C

D

B

N

24 X24 ACOUSTIC CEILING TILE

AT-1: 09 51 00.A3 & 09 51 00.B1

AT-6: 09 51 00.A3.1 & 09 51 00.B1

AT-8: 09 51 00.A5.2 & 09 51 00.B2

24 X24 WASHABLE ACOUSTIC CEILING TILE

AT-5: 09 51 00.A3.2 & 09 51 00.B1

AT-7: 09 51 00.A1.1 & 09 51 00.B2

PAINTED GYPSUM BOARD CEILING ON METAL

STUD FRAMING: P20 FOR ALL SURFACES AND

P20A FOR WASHABLE SURFACES, TYPICAL UON MOTORIZED INTERIOR, ROLLER SHADE - SUNSCREEN, O.F.C.I.

PAINTED PLASTER CEILING ON METAL STUD

FRAMING

PAINTED SUSPENDED GYPSUM BOARD CEILING:

P20 FOR ALL SURFACES AND P20A FOR

WASHABLE SURFACES, TYPICAL UON

SCS-1: 09 22 16.A2

24 x 72 ACOUSTIC CEILING TILE

AT-2: 09 51 00.A7.1 & 09 51 00.B1

AT-11: 09 51 00.A7 & 09 51 00.B2

48 x 48 ACOUSTIC CEILING TILE

AT-3: 09 51 00.A8 & 09 51 00.B2

AT-4: 09 51 00.A8.1 & 09 51 00.B2

CURTAIN TRACK PER DETAIL 13/AE602 AND IN SHEETS

FOR ADDITIONAL INFORMATION, O.F.C.I.

PATIENT LIFT TRACK PER DETAILS ON SJ801, O.F.C.I.

ALL STRUCTURAL UNISTRUT/SUPPORT/BRACING ARE BY

GENERAL CONTRACTOR, PER DETAILS ON SJ801

SCS-1

PAINTED SUSPENDED PLASTER CEILING

SCS-2: 09 22 16.A3

SCS-3

MANUAL INTERIOR, CHAIN DRIVE ROLLER SHADE -

SUNSCREEN, O.F.C.I.

CEILING PROJECTOR AND PROJECTION SCREEN PER

DETAILS 14 AND 18 , O.F.C.I.

WP-4 : WOOD PANELLING CEILING, SEE FINISH

SCHEDULE

COVE LIGHT, SEE ELECTRICAL SHEETS

WOODWORKS GRILLE CEILING SYSTEM

AT-9: 09 51 00.XX

24 X 48 ACOUSTIC CEILING TILE FOR WOODWORKS

GRILLE CEILING SYSTEM

AT-10: 09 51 00.A2 & 09 51 00.B2

TELESCOPIC TABLE PER EQUIPMENT SHEET AQ423.

LOCATE CENTER OF ACOUSTIC TILE

METAL PANEL CEILING, SEE AE502 & AE503

SCS-2

1. REFER TO SHEET GI006 FOR TYPICAL ABBREVIATIONS.

2. INTERIOR FINISH SCHEDULE SEE SHEET IN601.

3. SEISMIC BRACING FOR SUSPENDED T-BAR CEILING SEE SHEET AE601.

4. SEISMIC BRACING FOR SUSPENDED GYPSUM BOARD CEILING SEE SHEET AE601.

5. ALL EXPOSED DUCT WORK ELECTRICAL CONDUIT, PIPING, ETC. EXCEPT IN ROOMS NOT FINISHED SHALL BE PAINTED.

6. LIGHT FIXTURES AND MECHANICAL REGISTERS ARE SHOWN FOR LOCATION PURPOSES ONLY. REFER TO ELECTRICAL AND MECHANICAL

DRAWINGS FOR ADDITIONAL INFORMATION.

7. SPRINKLER HEADS IN SUSPENDED T-BAR CEILINGS SHALL BE CENTERED IN PANELS, REFER TO FIRE PROTECTION FLOOR PLANS FOR ADDITIONAL

INFORMATION.

8. A SUSPENDED T-BAR CEILING GRID SYSTEM ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF A SPACE IS LOCATED AT THE CENTER OF THE SPACE, UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE LOCATED AT THE CENTER OF THE SUSPENDED T-BAR CEILING TILE/GYPSUM BOARD CEILING IS LOCATED AT THE CENTER OF THE TILE/CEILING UNLESS OTHERWISE NOTED. A CEILING OBJECT ON THE DRAWING APPEARS TO BE ALIGNED TO EACH OTHER IS ALIGNED TO EACH OTHER UNLESS OTHERWISE NOTED.

9. COORDINATE DRYWALL EXPANSION CONTROL WITH MANUFACTURER AND ARCHITECT TO MEET USGBC STANDARD.

10. FIRE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER HEAD LOCATION WITH CASEWORK.

11. FOR THE LOCATION OF SMOKE DETECTORS, REFER TO FIRE ALARM SHEETS.

12. FOR THE LOCATION OF CEILING EQUIPMENTS, REFER TO AQ SHEETS.

13. FOR THE LOCATION OF FIRE SPRINKLER HEADS, REFER TO FIRE PROTECTION FX SHEETS.

14. ADJUST SUSPENSION WITH HEAVY DUTY MAIN RUNNERS AND CROSS MEMBERS TO ACCOMMODATE LOCATION OF MECHANICAL DIFFUSERS.

WP-4

8' - 2 1/2"

WP-4

8' - 2 1/2"

SCS-1

8' - 6"

SCS-1

11' - 0"

AT-2

9' - 0"

8' - 0"

IN802

IN802

AE604

EMERGENCY LIGHT

PER ELEC. SHEETS

LIGHT FIXTURES

PER ELEC. SHEETS

EQ EQ

COVE LIGHT PER

ELEC. SHEETS

FIRE SPRINKLER

HEAD PER FX SHEETS

WP-4

8' - 2 1/2"

WP-4

8' - 2 1/2"

SCS-1

8' - 6"

IN802

IN802

AE604

AE604

AT-2

9' - 0"

AT-2

9' - 0"

8' - 0"

EMERGENCY LIGHT

PER ELEC. SHEETS

LIGHT FIXTURE PER

ELEC. SHEETS

LINEAR SUPPLY

DIFFUSER PER

MECH. SHEETS

EQ EQ AE711

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:4

:5

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

AB

ENLARGED FOURTH FLOOR RCP -

PART C

AE114C

664-401

07/19/2019 AB/JT

SCALE: 1/8" = 1'-0"

FOURTH FLOOR REFLECTED CEILING PLAN - PART C

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDREFLECTED CEILING PLAN LEGEND

SCALE: 3/16" = 1'-0"

PORTAL ENTRY C - TYPICAL

SCALE: 3/16" = 1'-0"

PORTAL ENTRY B - TYPICAL

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

LMIO

LMIO

LMRC

LMIO

U

U

A

A

F

ELEVATOR

LOBBY

5A101

ELEVATOR

LOBBY

RESIDENT

TOILET

5B103

RESIDENT

TOILET

STORAGE

5A103

STORAGE

STAIR 1

5A21

STAIR 1

STAIR 2

5B06

STAIR 2

PENTHOUSE

5B101

PENTHOUSE

PENTHOUSE

5A104

PENTHOUSE

SHAFT 3

5A107

SHAFT 3

ROOF

ACCESS

ROOF

ACCESS

SERVICE

ELEVATOR

5AS2

SERVICE

ELEVATOR

SERVICE

ELEVATOR

5AS1

SERVICE

ELEVATOR

SERVICE

ELEVATOR

LOBBY

5A102

SERVICE

ELEVATOR

LOBBY

PASSENGER

ELEVATOR

5AP1

PASSENGER

ELEVATOR PASSENGER

ELEVATOR

5…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .