This is a presolicitation notice for a firm fixed-price construction contract. The Department of the Army Corps of Engineers is seeking proposals for the construction of a new Spinal Cord Injury and Community Living Center building and parking structure at the Veterans Affairs Healthcare System campus in San Diego, California. The project includes a 197,000 square foot expansion building with a 50-bed spinal cord injury center and 33-bed community living center, as well as associated clinics, therapy spaces, and site work. An 800-space parking structure is also part of the project. The estimated cost range is $100-250 million. The solicitation will be posted on October 31, 2019 with proposals due January 21, 2020. The North American Industry Classification code is 236220 and the contract has a performance period of three years from notice to proceed. This is an unrestricted procurement with Hubzone price evaluation preference.

Plans - SCICLC - Volume 1 Part 2

View the file

Other files

File Type Posted
W912PL-20-R-0004_Amendment0012.pdf PDF
W912PL-20-R-0004 Amendment 0011.pdf PDF
W912PL-20-R-0004_Amendment0010.pdf PDF
W912PL-20-R-0004 Amendment 0009.pdf PDF
W912PL20R0004_Amendment0008.pdf PDF
J and A Sole Source redacted Edwards EST3.pdf PDF
J and A Sole Source redacted Schlage Primus.pdf PDF
W912PL-20-R-0004 Amendment 0007.pdf PDF
W912PL20R0004_Amendment0006.pdf PDF
W912PL-20-R-0004_Amendment0005.pdf PDF
W912PLR0004_Amendment0004.pdf PDF
W912PL-20-R-0004_Amendment0003.pdf PDF
W912PL-20-R-0004_Amendment0002.pdf PDF
Sign-In Roster_SiteWalk_VA SD_2019.11.21.pdf PDF
W912PL20R0004 SF-1442_Amend0001 .pdf PDF
W912PL20R0004 SF-30_Amend0001.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part3.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL3_ParkingGarage.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2B.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part2.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL4_Appendices.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL2_SCICLC1TO4of4.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL1_SCI-CLCandParkingGarage.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL3..pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2H.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part3.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL2..pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2E.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part4.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2D.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part1.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ADMIN BUILDING

BUILDING 13

ADMIN BUILDING

PARKING STRUCTURES 2 & 3

(949) 250-1500

2355 Main Street Suite 220

Irvine, CA 92514

Project No. 215034.00

Pasadena, California 91101

Phone: 626.463.2600 Fax: 626.463.2801

300 N. Lake Avenue, 14th Floor www.ttgcorp.com

STRUCTURAL

ELECTRICAL

MECHANICAL

CIVIL

.TTG

Project Title Project Number

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

664-401

Date

Location

Reviewed

EBA

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

09/19/2019

S

I

T

A

E

T

S

L

N

E

C

C

N

O

C

F

O F

I

L

A

R

A

I

T

I

C

R A

D

E H

E

T

REN.: 10-31-19

NO. C-28367

DAVID HUNT

SCI BUILDING 26

PROPOSED

Solicitation Number: W912PL20R0004

(949) 250-1500

2355 Main Street Suite 220

Irvine, CA 92514

Project No. 215034.00

Pasadena, California 91101

Phone: 626.463.2600 Fax: 626.463.2801

300 N. Lake Avenue, 14th Floor www.ttgcorp.com

STRUCTURAL

ELECTRICAL

MECHANICAL

CIVIL

.TTG

Project Title Project Number

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

664-401

Date

Location

Reviewed

EBA

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

09/19/2019

S

I

T

A

E

T

S

L

N

E

C

C

N

O

C

F

O F

I

L

A

R

A

I

T

I

C

R A

D

E H

E

T

REN.: 10-31-19

NO. C-28367

DAVID HUNT

MODEL NO. / DESCRIPTION

IRRIGATION MATERIAL LEGEND

FQ T H

SYMBOL

MANUFACTURER DETAILRADIUSPSIFLOW RATE (GPM)

PVC PIPE 3/4" - 3" SCH. 40, SOLVENT WELD WITH SCH. 40 PVC FITTINGS, AS LATERAL LINES INSTALLED 12" BELOW FINISHED GRADE

PAVING, HARDSCAPE, ETC. (OR AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE) INSIDE SLEEVES. SLEEVES UNDER PEDESTRIAN PAVING

PVC PIPE SCH. 40 AS SLEEVING, 2.5 TIMES THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED (2" MINIMUM SIZE) INSTALL ALL PIPE AND WIRE UNDER

P7079D POLYETHYLENE INSULATED, SOLID COPPER CONDUCTOR IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED). PILOT

DBR/Y-6 DIRECT BURIAL (I.L. APPROVED) WATER-PROOF WIRE CONNECTORS FOR USE ON ALL WIRE SPLICES AND CONNECTIONS

120 VOLT ELECTRICAL POWER FOR CONTROLLER, PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD

AS APPROVED

AS APPROVED

N/A

3M

PAIGE ELECTRIC

MODEL LHM15TG1-MEL 11/2" NORMALLY CLOSED, MASTER CONTROL VALVE / FLOW SENSOR / HYDROMETER COMBINATION

975XLS, 2" R/P BACK FLOW PREVENTION DEVICE WITH WYE STRAINER, INSTALL WITH BRASS NIPPLES, UNIONS AND FITTINGS, SIZED PER DEVICE

LASCO

NETAFIM

WILKINS

HYDROPOINT

KSC-XXX-S SWING CHECK VALVE, LATERAL LINE SIZE, INSTALL ONE (1) ON THE DOWNSTREAM SIDE OF EACH RCV WHEN THE RCV IS LOWER THANNDS (K.B.I.)

STRONG BOX SBBC-45SS "SMOOTH TOUCH" STAINLESS STEEL BACK FLOW DEVICE ENCLOSUREV.I.T.

LASCO

AS APPROVED

VXX101N-SC XX" SLO-CLOSE SCH. 80 PVC, TRUE-UNION BALL VALVE WITH SOLVENT WELD SOCKET CONNECTIONS, LINE SIZE PER MAINLINE.

TYPE 'K' COPPER PIPING ROUTED BETWEEN PLANTERS, AND THROUGH BUILDING AND GARAGES. COPPER PIPING SHALL BE DESIGNED BY THEAS APPROVED

AS APPROVED

PVC PIPE 2" - 2 1/2" CL. 315, SOLVENT WELD WITH SCH. 80 PVC FITTINGS, AS MAINLINES INSTALLED 18" BELOW FINISHED GRADEAS APPROVED

RAIN BIRD 30.50 (1.0 TOTAL) 5 FT A,B

11/4" SCH. 40 PVC, GRAY ELECTRICAL CONDUIT FOR FLOW SENSOR / MASTER VALVE WIRES OR CENTRAL CONTROL COMMUNICATION CABLE, PROVIDE

PULL BOX AT A MAXIMUM OF 200 FEET ON CENTER FOR A 3 FOOT WIRE LOOP OR ANY SPLICES. INSTALL INSIDE A STANDARD RECTANGULAR VALVE BOX.

CONNECTION POINT BETWEEN COPPER PIPING (PROVIDED BY PLUMBER) AND PVC IRRIGATION PIPING. COPPER PIPE STUB-OUT SHALL HAVE A LINE

SIZED SWEAT X FIPT COPPER ADAPTER PROVIDED FOR CONNECTION TO THE IRRIGATION PIPING. USE A LINE SIZED X 6" SCH. 80 T.O.E. PVC NIPPLE AND

A LINE SIZED PVC COUPLING FOR THE CONNECTION. VERIFY LOCATION, SIZE AND STUB-OUTS OF COPPER PIPING IN THE FIELD PRIOR TO STARTING WORK.

ALL FITTINGS USED WITH SOLVENT WELD MAINLINE PIPE SHALL BE SCH. 80 PVC FITTINGS, GRAY IN COLOR, AND SIZED TO MATCH THE THR MAINLINE

PIPE. ALL FITTINGS USED WITH SOLVENT WELD LATERAL LINE PIPE SHALL BE SCH. 40 PVC, WHITE IN COLOR, AND SIZED TO MATCH THE LATERAL

LINE PIPE. ALL THREADED PVC NIPPLES SHALL BE SCH. 80 PVC PIPE, DARK GRAY IN COLOR, WITH MOLDED THREADS.

P.R. (TRI.)

N/A

.40, .57, .74, 1.47

.86, 1.34, 1.82, 3.64

40 30 FT

20 FT A,D0.45 IN./HR.

0.45 IN./HR.

1806-SAM 6" POP-UP TURF HEAD W/ MP LCS/RCS/SS530 NOZZLES .22, .44 40 4X15 FT A,D0.47 IN./HR.

THE SPRINKLERS, BUBBLERS OR DRIP EMITTERS. INSTALL WITHIN SPRINKLER / BUBBLER / DRIP ZONES AS REQUIRED TO PREVENT LOW HEAD DRAINAGE.

CHRISTY'S ALL SOLVENT WELD CONNECTIONS FOR BOTH MAINLINE AND LATERAL LINE SHALL BE MADE USING THE TWO-STEP PROCESS OF PRIMER AND SOLVENT

CEMENT. PRIMER SHALL BE LOW VOC "PURPLE PRIMER". MAINLINE SOLVENT CEMENT SHALL BE LOW VOC, "GRAY-HEAVY BODY" CEMENT. LATERAL

LINE SOLVENT CEMENT SHALL BE LOW VOC, "RED HOT BLUE GLUE" CEMENT. USE DAUBERS SIZED AT LEAST ONE-HALF THE SIZE OF THE LARGEST PIPE

BEING JOINED. ALL SOLVENT CEMENTED JOINTS SHALL BE MADE PER THE PIPE AND FITTING MANUFACTURER'S RECOMMENDATIONS.

RAIN BIRD

LASCO

RAIN BIRD

1806-SAM 6" POP-UP TURF HEAD WITH A MP2000-90(Q/T/H)/360 ADJUSTABLE NOZZLE

1806-SAM 6" POP-UP TURF HEAD WITH A MP3000-90(Q/T/H)/360 ADJUSTABLE NOZZLE

1806-SAM 6" POP-UP TURF HEAD WITH A MP1000-90(Q/T/H)/360 ADJUSTABLE NOZZLE

.19, .28, .37, .75 40 14 FT A,D0.45 IN./HR.

CONNECTION BETWEEN XFS DRIP TUBING AND PVC SUPPLY AND DISCHARGE HEADERS SHALL BE MADE USING XF DRIP LINE BARBED FITTINGS, SCH. 40

PVC THREADED FITTINGS, SCH. 80 NIPPLES AND FLEXIBLE NIPPLES. WHEN THE CONNECTION IS AT THE END RUN OF THE TUBING USE A 1/2" SCH. 40 PVC

SHALL BE INSTALLED USING A FITINS-TOOL FOR PROPER INSERTION OF THE FITTING INTO THE TUBING. NO HEATING OF TUBING SHALL BE ALLOWED.

1/2" SCH. 40 PVC BALL VALVE WITH SLIP ENDS AND A LASCO MHT-105 3/4" MHT X 1/2" SPIGOT ADAPTER WITH A LASCO FHT-301 HOSE THREAD CAP, FOR

USE AS A DRIP TUBING FLUSH VALVE. SEE PLANS FOR LOCATIONS. INSTALL INSIDE A 10" ROUND VALVE BOX.

ARV050 AIR/VACUUM RELIEF VALVE INSTALLED WITH A XFD-TFA-075 BARB X BARB X 3/4" FIPT TEE FITTING AND A AND A 3/4" X 1/2" SCH. 40 PVC THREADED

REDUCER BUSHING. INSTALL AIR RELIEF ASSEMBLY AT THE HIGH POINT OF EACH PLANTER. SEE PLANS FOR APPROXIMATE LOCATION AND QUANTITY OF

ARV'S PER DRIP ZONE. USING AN AIR RELIEF LATERAL CONSTRUCTED OF XFD "BLANK" XF TUBING, CONNECT AIR RELIEF VALVE TO ALL DRIP LINE

XFS-06-12 SUBSURFACE DRIP TUBING (COPPER EXTERIOR COLOR) WITH 0.60 GPH, PRESSURE COMPENSATING EMITTERS INTERNALLY INSTALLED IN THE

DRIP EMITTER. DRIP TUBING SHALL BE INSTALLED 2" BELOW FINISHED SOIL GRADE (NOT COUNTING MULCH) AND IN PARALLEL ROWS A MAXIMUM OF 16"

ON CENTER. THE PERIMETER ROW OF DRIP TUBING SHALL BE INSTALLED A MAXIMUM OF 4" FROM THE EDGE OF ANY HARDSCAPE OR TURF EDGE. ALL

SUBSEQUENT INTERIOR ROWS SHALL BE ADJUSTED TO PROVIDE AN EVEN SPACING ACROSS THE PLANTER WITHOUT EXCEEDING 16" MAXIMUM SPACING.

INSTALL 9" PVC COATED GALVANIZED TUBING STAKES A MAXIMUM OF FIVE (5) FEET ON CENTER ALONG THE LENGTH OF THE TUBING. TUBING STAKES

THREADED 90° ELBOW, A 1/2" X LENGTH AS REQUIRED SCH. 80 PVC THREADED NIPPLE, A 1/2" X 6" MIPT X FIPT FLEXIBLE NIPPLE, AND A XFF-MA-050 17mm

BARB X 1/2" MIPT ADAPTER FITTING. WHEN THE CONNECTION IS IN THE MIDDLE OF THE TUBING RUN USE A 1/2" SCH. 40 PVC THREADED TEE FITTING, A

1/2" X LENGTH AS REQUIRED SCH. 80 PVC THREADED NIPPLE, A 1/2" X 6" MIPT X FIPT FLEXIBLE NIPPLE, AND TWO (2) XFF-MA-050 17mm BARB X 1/2" MIPT

ADAPTERS. ALL END RUNS OF TUBING SHALL BE CONNECTED WITH A PVC DISCHARGE HEADER. FLEXIBLE NIPPLES SHALL BE MODEL #GFN050600 AS

PVC SUPPLY AND DISCHARGE HEADERS SHALL BE PVC LATERAL LINE PIPE (AS SHOWN BELOW), 1 1/4" MINIMUM SIZE WITH SCH. 40 PVC FITTINGS.

THESE VINE PLANTINGS. THE CONTRACTOR SHALL INSTALL TWO (2) XB-10PC 1 GPH DRIP EMITTERS PER VINE PLANTING. THESE ADDITIONAL EMITTERS

WHERE VINES ARE PLANTED ON WALLS, FENCES OR COLUMNS WITHIN THE DRIP TUBING ZONES, ADDITIONAL DRIP EMITTERS SHALL BE REQUIRED FOR

SHALL BE PUNCHED DIRECTLY INTO THE DRIP TUBING. EMITTERS SHALL BE INSTALLED USING A XM-TOOL EMITTER INSTALLATION TOOL. EACH DRIP

LOCATE EMITTER OUTLETS DIRECTLY OVER THE ROOT BALL OF THE VINE PLANTING.

REPRESENT THE APPROXIMATE DIRECTION AND SPACING OF THE DRIP TUBING ROWS, SEE ACTUAL SPACING REQUIREMENTS ABOVE AND IN DETAILS.

DRIP TUBING AT 12" O.C. SPACING. DRIP TUBING SHALL BE EQUIPPED WITH COPPER CHIP TECHNOLOGY TO PREVENT ROOT INTRUSION INTO THE

MANUFACTURED BY GPH IRRIGATION PRODUCTS (866) 582-9684.

SHALL BE MODEL #GDTS140900 AS MANUFACTURED BY GPH IRRIGATION PRODUCTS (866) 582-9684. THE HATCH PATTERN SYMBOLS ON THE PLANS

XF SERIES 17mm BARBED FITTINGS FOR ALL CONNECTIONS BETWEEN DRIP TUBING (TUBING-TO-TUBING ONLY). ALL BARBED DRIP TUBING FITTINGS

EMITTER SHALL BE INSTALLED WITH AN 18" LENGTH OF XQ-1/4" DISTRIBUTION TUBING, A TS-025 TUBING STAKE AND A DBC-025 DIFFUSER BUG CAP.

RAIN BIRD

RAIN BIRD

AS APPROVED

RAIN BIRD

LATERALS WITHIN THE ELEVATED AREA. MULTIPLE ARV'S MAY BE REQUIRED PER DRIP TUBING ZONE, SEE PLANS. INSTALL INSIDE A 7" ROUND VALVE BOX.

NO SYMBOL

NO SYMBOL

NO SYMBOL

NO SYMBOL

INSTALL INSIDE A 10" ROUND VALVE BOX.

44LRC 1" QUICK COUPLER VALVE WITH LOCKING VINYL COVER AND A LASCO G13S-218 SWING JOINT. INSTALL INSIDE A 10" ROUND VALVE BOX.RAIN BIRD

RAIN BIRD

RAIN BIRD

RS-500 WIRED RAIN SENSOR, MOUNT IN RGVRSS ENCLOSURE ON THE SIDE OF THE CONTROLLER ENCLOSURE, WIRE TO THE CONTROLLER.RAIN MASTER

A,D

4X30 FT

RAIN BIRD 1806-SAM 6" POP-UP "INDICATOR HEAD" WITH A 10 SERIES VAN NOZZLE (PAINT NOZZLE BRIGHT ORANGE). INSTALL INDICATOR HEAD ON A DISCHARGE

HEADER OF THE DRIP SYSTEM ZONE AND WITHIN SIGHT OF THE DRIP REMOTE CONTROL VALVE. ADJUST VAN NOZZLE TO FULLY CLOSED.

SHALL BE INSTALLED 24" BELOW FINISHED GRADE. SLEEVES UNDER VEHICULAR PAVING SHALL BE INSTALLED 36" BELOW FINISHED GRADE.

NO SYMBOL

NO SYMBOL

AS APPROVED ALL SOLVENT WELD MAINLINES ABOVE 2" IN SIZE SHALL HAVE CONCRETE THRUST BLOCKING INSTALLED AT ALL DIRECTIONAL CHANGES INCLUDING

ELBOWS (45° AND 90°) AND TEES. MAINLINE PIPES UNDER 2" SIZE AND ALL LATERAL LINES DO NOT REQUIRE THRUST BLOCKING.

NO SYMBOL

NO SYMBOL

PLUMBING ENGINEER AND BE SHOWN ON THE PLUMBING PLANS. COPPER PIPING SHALL BE INSTALLED BY THE PLUMBER. COPPER PIPING SHOWN

IS FOR REFERENCE ONLY. VERIFY LOCATION, SIZE AND STUB-OUTS OF COPPER PIPING IN THE FIELD PRIOR TO STARTING WORK.

WIRES SHALL BE RED IN COLOR, COMMON GROUND WIRE SHALL BE WHITE IN COLOR, SPARE WIRES SHALL BE YELLOW IN COLOR. WHERE MULTIPLE

CONTROLLERS ARE USED ON THE PROJECT, EACH CONTROLLER SHALL HAVE A DIFFERENT COLOR FOR PILOT WIRES. THE CONTRACTOR SHALL ROUTE

TWO (2) SPARE CONTROL WIRES (YELLOW) FROM THE CONTROLLER ALONG THE MAINLINE IN ALL DIRECTIONS AWAY FROM THE CONTROLLER. LOOP

SPARE WIRES UP AND INTO EACH VALVE BOX ALONG THE MAINLINE, PROVIDING A 3 FOOT MINIMUM LOOP.

NO SYMBOL

NO SYMBOL

NO SYMBOL

KC-XXX-S SPRING CHECK VALVE, LATERAL LINE SIZE, INSTALL ONE (1) ON THE DOWNSTREAM SIDE OF EACH RCV WHEN THE RCV IS HIGHER THAN

THE SPRINKLERS, BUBBLERS OR DRIP EMITTERS. INSTALL WITHIN SPRINKLER / BUBBLER / DRIP ZONES AS REQUIRED TO PREVENT LOW HEAD DRAINAGE.

NO SYMBOL

ALL VALVE BOXES SHALL BE VB SERIES, PLASTIC TYPE WITH OVERLAPPING LIDS. COVERS FOR BOXES IN TURF AREAS SHALL BE GREEN AND COVERS

FOR VALVE BOXES IN SHRUB AREAS SHALL BE BLACK. ALL BOXES SHALL BE SECURED WITH A RAIN BIRD VB-LOCK-P PENTA HEAD BOLT, WASHER AND

CLIP. BOXES SHALL BE AS SHOWN BELOW:

DESCRIPTION

10" ROUND BOXES

STANDARD RECTANGULAR BOXES

JUMBO RECTANGULAR BOXES

7" ROUND BOXES

VB-10RND

VB-7RND

VB-STD

VB-JMB

TURF AREAS (GREEN)

VB-10RVD-B BODY AND VB-10RNDBKL LID

VB-7RNDBK

VB-STD-B BODY AND VB-STDBKL LID

VB-JMB-B BODY AND VB-JMBBKL LID

SHRUB AREAS (BLACK)

RAIN BIRDNO SYMBOL

THE CONTROLLER SHALL BE GROUNDED USING A #182000 5/8" X 8 FOOT COPPER CLAD GROUND ROD, A #182005 CAST BRONZE ROD CLAMP ANDPAIGE ELECTRICNO SYMBOL

THE REQUIRED LENGTH OF #6AWG BARE, SINGLE STRAND COPPER GROUND WIRE. INSTALL INSIDE A 10" ROUND VALVE BOX.

E,F,G

E,F,G

E,F,G

E,F,G

E,F,G

F,H

F,I

F

WR-01

WR-01

J

K

L

M

N

O,P,Q

Q

N/A

N/A

R

R

S

N/A

N/A

U

N/A

N/A

N/A

R,S,T

T

N/A

N/A

N/A

NDS (K.B.I.)

.23, .33, .42, .78

.40, .57, .74, 1.47

.86, 1.34, 1.82, 3.64

40 30 FT

20 FT

10 FT

A

A0.81 IN./HR.

0.45 IN./HR.

0.45 IN./HR.

.22, .44 40 4X15 FT A0.47 IN./HR.

.19, .28, .37, .75 40 14 FT A0.45 IN./HR.

A

4X30 FT

RAIN BIRD

30.50 (1.0) N/A C

1402 BUBBLER HEAD ON TOP OF A SCH. 80 NIPPLE, INSTALLED BENEATH TREE GRATE

PER DETAIL, EACH SYMBOL REPRESENTS TWO BUBBLERS PER TREE, PLACE BUBBLERS

AT EDGE OF ROOTBALL ON OPPOSITE SIDES OF TREE.

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

RAIN BIRD / HUNTER

1806-SAM 6" POP-UP BUBBLER HEAD WITH A RAIN BIRD 5Q-B STREAM BUBBLER

NOZZLE, EACH SYMBOL REPRESENTS TWO (2) BUBBLERS PER TREE OR PALM, PLACE

BUBBLERS AT EDGE OF ROOT BALL ON OPPOSITE SIDES OF TREE OR PALM, TYPICAL.

ADJUST BUBBLER STREAMS TO WET THE ROOT BALL AND AMENDED SOIL WITHOUT

HITTING THE TRUNK OF THE TREE OR PALM.

1812-SAM 12" POP-UP SHRUB HEAD WITH A MP800SR-90/360 ADJUSTABLE NOZZLE

1812-SAM 12" POP-UP SHRUB HEAD WITH A MP1000-90(Q/T/H)/360 ADJUSTABLE NOZZLE

1812-SAM 12" POP-UP SHRUB HEAD WITH A MP2000-90(Q/T/H)/360 ADJUSTABLE NOZZLE

1812-SAM 12" POP-UP SHRUB HEAD WITH A MP3000-90(Q/T/H)/360 ADJUSTABLE NOZZLE

1812-SAM 12" POP-UP SHRUB HEAD W/ MP LCS/RCS/SS530 NOZZLES

N/A

EFB-CP-PRS-D PRESSURE REGULATING, BRASS REMOTE CONTROL VALVE (RCV), SIZE AS SHOWN (1", 1 1/2" AND 2" SIZES), SET PRS-D

PRESSURE REGULATOR TO PROVIDE THE OPERATING PRESSURE OF THE SPRINKLER / BUBBLER HEAD TO THE HIGHEST OR FARTHEST HEAD

ON THE CONTROL VALVE ZONE. INSTALL THE RCV INSIDE A STANDARD RECTANGULAR VALVE BOX.

EFB-CP-PRS-D DRIP REMOTE CONTROL VALVE, SIZE AS SHOWN (1" AND 1 1/2" SIZES). INSTALL A DISC FILTER AND AN INLINE PRESSURE

REGULATOR ON THE DOWNSTREAM SIDE OF EACH DRIP REMOTE CONTROL VALVE (DRCV). FOR 1" DRCV'S INSTALL A RAIN BIRD LCRBY-100D DISC

FILTER AND A SENNINGER 1" PMR-40-MF PRESSURE REGULATOR. FOR 1 1/2" DRCV'S INSTALL A RAIN BIRD LCRBY-150D DISC FILTER AND A

SENNINGER 1 1/4" PMR-40-HF PRESSURE REGULATOR. USE A 1 1/2" SCH. 40 PVC THREADED COUPLING, A 1 1/2" X 1 1/4" PVC THREADED REDUCER

BUSHING, AND A 1 1/4" X 2" SCH. 80 PVC NIPPLE AS REQUIRED TO CONNECT THE 1 1/4" REGULATOR TO THE DOWNSTREAM SIDE OF THE 1 1/2"

FILTER. INSTALL THE DRCV ASSEMBLY INSIDE A JUMBO RECTANGULAR VALVE BOX.

1806-SAM WITH 1800-EXT SHALL BE USED IN SHRUB AREAS ON ROOF GARDENS W/ NOZZLES ABOVE

W

3/4" HOSE BIB ON RISER WITH VACUUM BREAKER VAS APPROVED

1806-SAM WITH 1800-EXT SHALL BE USED IN SHRUB AREAS ON ROOF GARDENS W/ NOZZLES ABOVE

W

CONTROLLER "A" WTPRO3-C-72-STW WEATHERTRAK ETPRO 3 (72 STATION) CONTROLLER INSTALLED WITHIN A WIDE TOP ENTRY ENCLOSURE.

CONTROLLER "B" WTPRO3-C-12-SWM WEATHERTRAK ETPRO 3 (12 STATION) CONTROLLER INSTALLED WITHIN A STAINLESS STEEL WALL MOUNTED ENCLOSURE.

EACH CONTROLLER IS COMPLETE WITH ONE (1) YEAR OF WEATHERTRAK CENTRAL SERVICE. CONTRACTOR SHALL PROVIDE ONE (1) RAINMASTER PRO-MAX UA

SERIES HAND HELD REMOTE AS PART OF TURN-OVER ITEMS.

975XLS, 11/2" R/P BACK FLOW PREVENTION DEVICE WITH WYE STRAINER, INSTALL WITH BRASS NIPPLES, UNIONS AND FITTINGS, SIZED PER DEVICEWILKINS WR-01

X

OPERATING PRESSURE (PSI)

ZONE AREA (SFT)

VALVE FLOW RATE IN G.P.M.

VALVE SIZE IN INCHES

CONTROLLER LETTER / STATION NUMBER

HYDROZONE NUMBER SEE CHART

IRRIGATION METHOD SEE CHART

ZONE PRECIPITATION RATE (IN./HR.)

LENGTH OF DRIP TUBING

FOR DRIP TUBING ZONES

VALVE CALLOUT LEGEND

NUMBER

DESCRIPTION OF THE HYDROZONE

SHRUBS WITH MP ROTATOR HEADS

2 SHRUBS WITH INLINE DRIP TUBING

3 TURF WITH MP ROTATOR HEADS

4 TREE BUBBLERS

HYDROZONE DESCRIPTION CHART

NUMBER DESCRIPTION OF THE IRRIGATION METHOD

BUBB BUBBLERS

DRIP DRIP TUBING

MPR OVERHEAD MP ROTATORS

IRRIGATION METHOD DESCRIPTION CHART

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

1. ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF

THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR

PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR.

2. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE

COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE

APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE

REPORTED TO THE OWNER'S REPRESENTATIVE.

3. THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING

WORK.

4. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN

BEFORE BEGINNING WORK.

5. THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO

BE INSTALLED WITHIN PLANTING AREAS.

6. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS

IN THE FIELD THAT UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE

PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE

PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD

CHANGES DEEMED NECESSARY BY THE OWNER.

7. INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE

TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION.

8. ACTUAL LOCATION FOR THE INSTALLATION OF THE BACKFLOW PREVENTER AND THE AUTOMATIC CONTROLLER IS

TO BE DETERMINED IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE.

9. CONTRACTOR IS TO PROVIDE AN ADDITIONAL PILOT WIRE FROM CONTROLLER ALONG ENTIRETY OF MAIN LINE TO

THE LAST RCV ON EACH AND EVERY LEG OF MAIN LINE. LABEL SPARE WIRES AT BOTH ENDS.

10. ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE

LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO

EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING

DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING.

11. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS

WHERE POSSIBLE. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED AS SHOWN ON THE

INSTALLATION DETAILS. INSTALL ALL QUICK COUPLER AND REMOTE CONTROL VALVES WITHIN 18" OF HARDSCAPE.

12. ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE

TO BE ADJUSTED TO PREVENT OVERSPRAY ONTO BUILDINGS, WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW, REPLACEMENT OF PRESSURE

COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS UNITS AND THE

REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS.

13. CONTRACTOR SHALL INSTALL ADDITIONAL CHECK VALVES TO HEADS AND LATERALS AS REQUIRED TO PREVENT

LOW HEAD DRAINAGE.

14. THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND

RELATED EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. SWEENEY AND ASSOCIATES RECOMMENDS

MEASURING FOR PROPER GROUND AT LEAST ONCE ANNUALLY, AND NECESSARY ADJUSTMENTS MADE TO COMPLY

WITH MANUFACTURER SPECIFICATIONS.

IRRIGATION NOTES

04/27/2018

04/27/2018

09/26/201806/22/2017

1LI001

07/19/2019

UP DN

SCI BUILDING

PROPOSED

X X X X X X X X X X

X

X X X X X X X X X X X X X X X

X

X X

X X

X

X X

X X

X

X X X X

X

X

X

X

X

X

X

X

X

X X X X X X X X

X X

X X

X

X

X X X X X

X X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X X

X X

X X

X X

X X

X X

X X

X X

X X

XXXXXXX

11/4"

3/4"

1"

3/4"

1"

1"

3/4"

1"

1"

11/4"

3/4"

1"

1"

11/4"

11/4"

3/4"

1"

1"

3/4"

1"

1"

11/4"

11/2"

3/4"

1"

3/4"

3/4"

1"

3/4"

1"

1"

1"

1"

1"

11/4"

1"

1"

1"

1"

3/4"

3/4"

1"

3/4"

3/4"

1"

1"

3/4"

11/4"

11/4"

3/4" 1" 1" 3/4"

1"

1"

3/4"

1"

3/4"

1"

1"

11/4"

11/4"

3/4"1"

1"

1"

3/4"

1"

1"

3/4"

1"

3/4"

3/4"

1"

1"

11/4"

3/4"

1"

1"

3/4"

1"

3/4"

1"

3/4"

3/4"

1"

11/4"

11/4"

3/4"

3/4"

3/4"

3/4" 1"

1"

3/4"

1"

1"

11/4"

11/4"

3/4"

3/4"

11/4"

11/2"

11/2"

3/4"

1"

1"

1"

3/4"

3/4"

1"

1"

1"

3/4"

1"

3/4"

3/4"

3/4"

1"

3/4" 3/4"

11/4"

3/4" 11/4"

11/4"

3/4"

3/4"

1"

1"

3/4"

1"

1"

3/4"1" 1"

11/4"

2"

3/4"

3/4" 3/4"

1"

3/4"

11/2"

3/4" 3/4"

3/4"

1" 1"3/4" 1" 1"

3/4" 3/4"

11/4"

11/2"

1"

1"

3/4"

3/4"

1"

3/4" 1"

3/4"

11/4"

1"

3/4"

3/4"

1"

1"

3/4"

1"

3/4"

3/4"

1"

11/4"

3/4"

3/4"

11/4"

3/4"

1"

3/4"

3/4"

1"

3/4"

1"

1"1"

3/4"

3/4"

1"

3/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

3/4"

1"

1"

11/4"

11/4"

11/4"

1"

3/4"

1"

3/4"

3/4"

3/4"

11/2"

3/4"

3/4"

1"

1"

3/4" 1"

1"

1"

3/4"

3/4"

11/4"

3/4"

1"

11/2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

1"

1"

1"

11/2"

11/2"

1"

2"

1"

11/4"

11/4"

1"

3/4"

2"

2"

2"

1"

11/4"

3/4"

11/2"

11/2"

11/4"

11/4"

11/4"

11/4"

3/4"

11/4"

11/2"

2"

2"

2"

1"

1"

1"

3/4"

11/2"

11/4"

11/4"

11/4"

1"

3/4"

11/4"

11/2"

1"

1"

3/4"

3/4"

1"

11/2"

1"

11/4"

3/4"

11/2"

2"

2"

3/4"

3/4"

1"

1"

1"

11/4"

11/4"

11/4"

1"

2"

2"

3/4"

1"

1"

11/4"

2"

2"

1"

11/4"

11/4"

11/4"

3/4" 1"

3/4"

1"

3/4"

3/4"

11/4"

3/4"

1"

1"

3/4"

11/2"

11/2"

11/2"

3/4"

3/4"

1"

1"

3/4"

3/4"

11/4"

11/4"

11/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

3/4"

11/4"

2"

2"

1"

1"

1"

1"

1"

3/4"

1"

11/2"

3/4"

3/4"

1"

3/4" 1"

11/4"

11/4"

3/4"

11/4"

11/4"

11/4"

11/2"

3/4"

11/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

11/2"

11/2"

3/4"

3/4"

1"

1"

11/4"

11/4"

3/4"

3/4"

1"

11/4"

3/4"

3/4"

1"

1"

3/4"

3/4"

3/4"

11/4"

11/4"

3/4"

11/2"

3/4"

3/4"

3/4"

11/4"

11/4"

3/4"

1"

1"

1"

1"

3/4"

11/4"

11/4"

2"

2"

11/4"

1"

1"

11/4"

1"

2"

2"

11/4"

11/4"

11/2"

11/2"

3/4"

1"

1"

1"

11/4"

11/4"

2"

2"

1"

1"

1"

11/4"

11/4"

1"

11/4"

3/4"

1"

11/4"

11/4"

3/4"

3/4"

3/4"

1" 1"3/4"

11/4"

1"

11/2"

3/4" 1" 1"

11/4"

3/4" 1"1"

1"

3/4"

3/4" 3/4"

3/4"

1"

1"

11/2"

2"

3/4"

1"1"

3/4"

1"1"

3/4"

1" 1" 11/4" 11/4"

3/4" 1"

3/4"1" 1"3/4" 1" 1"

11/4"

3/4" 1"

1" 11/4"

11/4"

11/2"

2"

1"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

4020100

N

LI

M

IT

O

F W

O

RK

LIMIT OF WORK

PHASE II PART A PARKING STRUCTURE

LIMIT OF WORK

LIM

IT O

F W O

RK

LIMIT OF WORK

LIMIT OF WORK

LIM

IT

O F

W O

RK

SEE SHEET 1-LI404.A

SEE SHEET 1-LI403.A

SEE SHEET 1-LI402.A

SEE SHEET 1-LI405.ASEE SHEET 1-LI401.A

FOR ENLARGEMENT

FOR ENLARGEMENT

FOR ENLARGEMENT

FOR ENLARGEMENT

FOR ENLARGEMENT

SCI TERRACE

PT/OT TERRACE

ATRIUM COURTYARD

ENTRY ROAD

ROSE GARDEN

LIM

IT O

F W O

RK

1. FOR GREEN ROOF

PLANS SEE LI105

2. FOR BALCONY

CONTAINER

PLANTERS SEE

SHEETS LI102-104

NOTES

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

POINT OF CONNECTION (POC) #1 SHALL BE A DOWNSTREAM OF AN EXISTING BACKFLOW.

THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER SIZE

AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT OF

THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE

WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN

USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY

THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER

PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE

MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE

POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE

ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE

LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR

FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED

BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE

CONTRACTOR.

WATER PRESSURE AT POC: 78 PSI (STATIC)

DESIGN WATER PRESSURE: 56 PSI

MAXIMUM SYSTEM DEMAND: 31 GPM

RESIDUAL WATER PRESSURE: 22 PSI

NOTE B:

CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON

THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE

APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE

REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S

AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL

POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE C:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE D:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE E:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

IRRIGATION POINT OF CONNECTION #1;

REFER TO NOTE "A"

IRRIGATION CONTROLLER "A";

REFER TO NOTE "B"

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI101

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

2ND FLOOR TERRACE

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NO IRRIGATION THIS SHEET

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI102

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

3RD FLOOR TERRACE

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NO IRRIGATION THIS SHEET

CONTAINER PLANTS TO BE HAND

WATERED VIA HOSE BIB BY OTHERS.

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI103

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NO IRRIGATION THIS SHEET

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

CONTAINER PLANTS TO

BE HAND WATERED VIA

HOSE BIB BY OTHERS.

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI104

FD

FD

F E

C

N C

N C

F E

C

F

E

C

F E

C

F E

C

F

E

C

F

E

C

ELEVATOR

LOBBY

5A101

ELEVATOR

LOBBY

RESIDENT

TOILET

5B102

RESIDENT

TOILET

RESIDENT

TOILET

5B103

RESIDENT

TOILET

STAIR 1

5A21

STAIR 1

STAIR 2

5B06

STAIR 2

PENTHOUSE

5B101

PENTHOUSE

PENTHOUSE

5A104

PENTHOUSE

SERVICE

ELEVATOR

LOBBY

5A102

SERVICE

ELEVATOR

LOBBY

SERVICE

STAIR - NO

EXIT

5A105

SERVICE

STAIR - NO

EXIT

STORAGE

5A103

STORAGE

C

O

P

P

E

R

M

A

I N

L

I N

E

3/4"

3/4"

3/4"

3/4"

1"

11/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

1"

3/4"

3/4"

1"

11/4"

11/2"

3/4"

3/4"

3/4"

1"

1"

11/4"

3/4"

3/4"

1"

3/4"

3/4"

11/4"

3/4"

3/4"

11/4"

3/4"

3/4"

2"

2"

2"

2"

2"

2"

11/4"

1"

C

O P

P E

R

M

A I N

L I N

E

C

O

P

P

L

T

E

R

A

L

C

O

P

P

T

E

R

A

L

C

O P

P E

R

L A

T E

R A

L

C

O

P P

E R

L A

T E

R A

L

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

1"

3/4"

3/4"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

5TH FLOOR ROOF TERRACELIMIT OF WORK

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

POINT OF CONNECTION (POC) #2 SHALL BE A 1.5" DOMESTIC DOMESTIC WATER COPPER

LINE. THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER

SIZE AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT

OF THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE

WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN

USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY

THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER

PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE

MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE

POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE

ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE

LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR

FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED

BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE

CONTRACTOR.

MINIMUM WATER PRESSURE AT POC: 70 PSI (STATIC)

DESIGN WATER PRESSURE: 64 PSI

MAXIMUM SYSTEM DEMAND: 18 GPM

RESIDUAL WATER PRESSURE: 06 PSI

NOTE B:

SYSTEM WAS DESIGNED FOR A MINIMUM REQUIRED STATIC WATER PRESSURE OF 70

PSI. CONTRACTOR SHALL VERIFY EXISTING STATIC WATER PRESSURE PRIOR TO

COMMENCING WORK. IF STATIC WATER PRESSURE IS LESS THAN THE 70 PSI MIN.

REQUIRED PRESSURE THEN CONTRACTOR SHALL NOTIFY THE IRRIGATION

CONSULTANT IMMEDIATELY.

NOTE C:

CONTROLLER "B" SHALL BE INSTALLED IN THE APPROXIMATE LOCATION SHOWN. THE

CONTRACTOR SHALL COORDINATE THE REQUIRED ELECTRICAL POWER SUPPLY AT THIS

LOCATION WITH THE OWNER'S AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF

CONTROLLER AND ELECTRICAL POINT OF CONNECTION SHALL BE CONFIRMED WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE D:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE E:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE F:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE G:

LATERAL LINE PIPING WITHIN BUILDING SHALL BE A TYPE K COPPER AND IS SHOWN FOR

CLARITY ONLY, ACTUAL DESIGN AND ROUTING SHALL BE COMPLETED BY PLUMBING

ENGINEER AND INSTALLED BY PLUMBING CONTRACTOR. EACH STUB-OUT WITHIN EACH

PLANTER SHALL HAVE A COPPER FEMALE ADAPTER FOR THE LANDSCAPE CONTRACTOR

CONNECTION. ALL PIPING THROUGH BUILDING TO EXTERIOR AND THROUGH BUILDING

TO UPPER FLOOR SHALL BE PROVIDED BY PLUMBER.

IRRIGATION POINT OF CONNECTION #2;

REFER TO NOTE "A"

IRRIGATION CONTROLLER "B";

REFER TO NOTE "C"

COPPER PIPING;

REFER TO NOTE "G"

COPPER PIPING LINES HERE ARE IN THE 4TH

FLOOR CEILING PLUMBER WILL PROVIDE A

COPPER TO PVC ADAPTER AT ALL

TERMINATION IN THE PLANTERS.;

REFER TO NOTE "G"

REDUCED PRESSURE PRINCIPLE BACKFLOW

PREVENTER TO BE INSTALLED PER SAN

DIEGO REGIONAL STANDARD DRAWING

WR-01, DETAIL F5 - 1CG503

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI105

UP

X X X X X X X X X X X X

1"

1"

11/4"

1"

1"

1"

1"

3/4"

3/4"

1"

3/4"

3/4"

1"

1"

3/4"

11/4"

11/4"

3/4" 1" 1" 3/4" 1"

1"

3/4"

1"

3/4"

1"

1"

11/4"

11/4"

3/4"1"

1"

1"

3/4"

1"

1"

3/4"

1"

3/4"

3/4"

1"

1"

11/4"

3/4"

1"

1"

3/4"

1"

3/4"

1"

3/4"

3/4"

1"

11/4"

11/4"

3/4"

3/4"

3/4"

3/4" 1"

1"

3/4"

1"

1"

11/4"

11/4"

3/4"

3/4"

11/4"

11/2"

11/2"

3/4"

1"

3/4"

3/4"

1"

1"

3/4"

3/4"

3/4"

3/4"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

2"

1"

11/4"

3/4"

11/2"

11/2"

11/4"

11/4"

11/4"

11/4"

3/4"

11/4"

11/2"

2"

2"

2"

1"

1"

1"

3/4"

11/2"

11/4"

11/4"

11/4"

1"

3/4"

11/4"

11/2"

1"

1"

3/4"

3/4"

1"

11/2"

1"

11/4"

3/4"

11/2"

2"

2"

1"

1"

11/4"

2"

1"

3/4" 1"

3/4"1" 1"3/4" 1" 1"

11/4"

3/4"

1"

1" 11/4"

11/4"

11/2"

2"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

LIM

IT O

F W O

RK

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

POINT OF CONNECTION (POC) #1 SHALL BE A DOWNSTREAM OF AN EXISTING BACKFLOW.

THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER SIZE

AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT OF

THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE

WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN

USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY

THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER

PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE

MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE

POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE

ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE

LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR

FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED

BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE

CONTRACTOR.

WATER PRESSURE AT POC: 78 PSI (STATIC)

DESIGN WATER PRESSURE: 56 PSI

MAXIMUM SYSTEM DEMAND: 31 GPM

RESIDUAL WATER PRESSURE: 22 PSI

NOTE B:

CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON

THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE

APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE

REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S

AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL

POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE C:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE D:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE E:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

IRRIGATION POINT OF CONNECTION #1;

REFER TO NOTE "A"

IRRIGATION CONTROLLER "A";

REFER TO NOTE "B"

CONTRACTOR SHALL CONNECT TO 1"

SUPPLY LINE FROM THE BUILDING TO

INSTALL A HOSE BIB, REFER TO EXACT

LOCATION ON THE PLUMBING PLANS.

(TYP.)

04/27/2018

04/27/2018

09/26/2018 06/22/201707/19/2019

F

D

F

D

FD

DN

F

D

F

D

SCI BUILDING

PROPOSED

X

X X

X X

X

X X

X X

X

X X X X

BUILDING 1

FF = 357.00

PROPOSED SCI BUILDING

1ST FLOOR FF = 347.00

2ND FLOOR FF = 363.00

11/4"

3/4"

1"

3/4"

1"

1"

3/4"

1"

1"

11/4"

3/4"

1"

1"

11/4"

11/4"

3/4"

1"

1"

3/4"

1"

1"

11/4"

11/2"

3/4"

1"

3/4"

3/4"

1"

3/4"

1"

1"

1"

1"

1"

1" 3/4" 1"

3/4"

1"

3/4" 1"

1"

3/4"

2"

2"

2"

1"

11/2"

11/2"

1"

2"

1"

11/4"

11/4"

11/4"

11/2"

1"

1"

3/4"

1"

11/2"

1"

11/4"

3/4"

11/2"

2"

2"

3/4"

3/4"

1"

1"

1"

11/4"

11/4"

11/4"

1"

2"

2"

3/4"

1"

1"

11/4"

2"

2"

1"

11/4"

11/4"

11/4"

3/4" 1"

3/4"

1"

3/4"

3/4"

11/4"

3/4"

1"

1"

3/4"

11/2"

11/2"

11/2"

3/4"

3/4"

1"

1"

3/4"

3/4"

11/4"

11/4"

11/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

3/4"

11/4"

2"

2"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON

THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE

APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE

REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S

AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL

POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE B:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE C:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE D:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

IRRIGATION CONTROLLER "A";

REFER TO NOTE "B"

LIMIT OF WORK

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI402.A

UP DN

FD

FD

UP

DN

SCI BUILDING

PROPOSED

BUILDING 11

FF = 357.00

BUILDING 2

FF = 315.08

3/4"

1"

3/4"

3/4"

3/4"

1"

1"

3/4" 1"

1"

1"

3/4"

3/4"

11/4"

3/4"

1"

11/2"

2"

2"

1"

1"

1"

1"

1"

1"

1"

3/4"

1"

3/4"

2"

2"

11/4"

1"

1"

11/4"

1"

1"

1"

1"

11/4"

11/4"

1"

11/4"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE B:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE C:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

LIMIT OF WORK

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI403.A

SCI BUILDING

PROPOSED

BUILDING 13

FF = 346.69

PROPOSED SCI BUILDING

1ST FLOOR FF = 347.00

2ND FLOOR FF = 363.00

1"

1"

3/4"

1"

1"

3/4" 1"

1"

11/4"

3/4"

3/4"

11/4"

3/4"

1"

3/4"

1"

1"1"

3/4"

3/4"

1"

3/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

3/4"

1"

1"

11/4"

11/4"

11/4"

1"

3/4"

1"

3/4"

3/4"

3/4"

11/2"

2"

2"

2"

2"

2"

2"

2"

2"

1"

3/4"

11/2"

3/4"

3/4"

1"

3/4" 1"

11/4"

11/4"

3/4"

11/4"

11/4"

11/4"

11/2"

3/4"

11/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

11/2"

11/2"

3/4"

3/4"

1"

1"

11/4"

11/4"

3/4"

3/4"

1"

11/4"

3/4"

3/4"

1"

1"

3/4"

3/4"

3/4"

11/4"

11/4"

11/2"

3/4"

3/4"

3/4"

11/4"

11/4"

3/4"

1"

1"

1"

1"

3/4"

11/4"

11/4"

1"

2"

2"

11/4"

11/2"

11/2"

3/4"

1"

1"

1"

11/4"

11/4"

2"

2"

3/4"

1"

11/4"

11/4"

1"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE B:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE C:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

LIM

IT O

F W O

RK

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI404.A

X X X X X X X X

X X

X X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

BUILDING 13

FF = 346.69

ADMIN BUILDING FF = 345.1

1"

1"

3/4"

3/4"

1"

1"

1"

3/4"

1"

3/4"

3/4"

3/4"

1"

3/4" 3/4"

11/4"

3/4" 11/4"

11/4"

3/4"

3/4"

1"

1"

3/4"

1"

1"

3/4" 1"

1"

11/4"

2"

3/4"

3/4" 3/4"

1"

3/4"

11/2"

3/4" 3/4"

3/4"

1" 1"3/4" 1" 1"

3/4" 3/4"

11/4"

11/2"

1"

1"

3/4"

3/4"

1"

3/4" 1"

3/4"

11/4"

1"

3/4"

3/4"

1"

1"

3/4"

1"

3/4"

3/4"

1"

11/4"

3/4"

3/4"

11/4"

1"1"

3/4"

3/4"

1"

2"

2"

2"

2"

2"

2"2"

2"

2"

2"

2"

3/4"

3/4"

1"

3/4" 1"

11/4"

3/4"

3/4"

11/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

3/4"

1"

1"

11/4"

3/4"

3/4"

3/4"

1"

11/4"

11/4"

11/2"

11/2"

3/4"

1"

1"

1"

11/4"

11/4"

2"

2"

3/4"

1"

11/4"

11/4"

3/4"

3/4"

3/4"

1" 1"3/4"

11/4"

1" 11/2"

3/4" 1" 1"

11/4"

3/4" 1"1"

1"

3/4"

3/4" 3/4"

3/4"

1"

1"

11/2"

2"

3/4"

1"1"

3/4"

1"1"

3/4"

1" 1" 11/4" 11/4"

1504 S.COAST HIGHWAY

LAGUNA BEACH, CA 92651

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

201050

N

LIM

IT O

F W O

RK

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

NOTE A:

THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION

EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION

OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A

MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.

NOTE B:

CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY

VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT

LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION

OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY

AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE

HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL

HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD

INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH

OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.

NOTE C:

THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN

WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE

PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE

PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE

CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED

REPRESENTATIVE PRIOR TO STARTING WORK.

LATERAL PIPE SIZE CHART

PIPE SIZE

3/4"

11/4"

11/2"

2"

1"

0-5

GALLONAGE

5-10

10-15

15-25

25-35

04/27/2018

04/27/2018

09/26/2018 06/22/2017

1LI405.A

949 497 8298 T 949 494 2421 F

LANDSCAPE ARCHITECTURE

W H I T I N D E S I G N W O R K S

619 497 2559 : 619 497 2666 fax

7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services

I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND

APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE

IRRIGATION DESIGN PLAN

HEIGHT AND NOZZLE REQUIRED

INSTALL SPRINKLER HEADS 4" FROM PAVING EDGE IN TURF AREAS.

SECTION VIEW - N.T.S.

DO NOT INSTALL USING SIDE INLET

FINISHED GRADE IN TURF AREAS

INSTALL POP-UP SPRINKLER HEAD FLUSH WITH

AND GROUND COVERS AREAS

ABOVE FINISHED GRADE IN SHRUB

INSTALL POP-UP SPRINKLER HEAD 1/2"

UNDISTURBED SOIL

LATERAL LINE, SEE SPECIFICATIONS

FOR TYPE AND DEPTH REQUIRED

LATERAL x SPRINKLER INLET SIZE

SCH 40 PVC SxSxT TEE FITTING

SIZE AS PER SPRINKLER INLET

LAY LENGTH TO BE 6" MINIMUM

SEE LEGEND FOR BRAND, MODEL, POP-UP

POP-UP SPRINKLER HEAD, SPRAY OR ROTOR,

PRE-ASSEMBLED TRIPLE SWING JOINT,

HUNTER SJ SERIES (OR APPROVED EQUAL)

LANDSCAPE AREA WITHOUT OVERSPRAY ONTO PAVING, FENCES, WALLS OR BUILDINGS.

INSTALL SPRINKLER HEADS PLUMB. ADJUST SPRAYS OR NOZZLE STREAM TO COVER

INSTALL SPRINKLER HEADS 6" FROM PAVING EDGE IN SHRUB AND GROUND COVER AREAS.

INSTALL SPRINKLER HEADS 12" FROM THE FACE OF BUILDING WALLS OR WINDOWS.

NOTE:

1/2"

FINISHED GRADE IN TURF AREAS

C

L

LASCO "SLO-CLOSE" SCH. 80 PVC,

BRICK SUPPORTS,

FINISHED GRADE IN SHRUB AREAS

PVC IRRIGATION MAINLINE,

6" PVC CL. 160 PIPE, LENGTH

ONE CUBIC FOOT OF

3/4" CRUSHED GRAVEL

6"

THREE REQUIRED

TRU-UNION BALL VALVE, SOLVENT

AS REQUIRED, 12" MINIMUM

SEE LEGEND FOR SPECIFICATION

WELD CONNECTIONS. SIZE BALL

SOLVENT WELD CONNECTIONS

VALVE PER THE MAINLINE SIZE

PROVIDE ONE 30" STEEL VALVE

KEY FOR EA. 3 VALVES INSTALLED

2"

AND CAPTIVE STAINLESS STEEL BOLT AND LOC-KIT.

PLASTIC 10" ROUND VALVE BOX WITH T-COVER

HEAT BRAND "BV" ONTO LID.

SECTION VIEW - N.T.S.

FINISHED GRADE IN TURF AREAS

C

L

QUICK COUPLING VALVE, SEE

BRICK SUPPORTS, 3 REQUIRED

FINISHED GRADE IN SHRUB AREAS

SCH 80 PVC SxSxT TEE FITTING, 3"

LEGEND FOR BRAND AND MODEL

MAINLINE x QCV INLET SIZE

2"

AND CAPTIVE STAINLESS STEEL BOLT AND LOC-KIT.

PLASTIC 10" ROUND VALVE BOX WITH T-COVER

HEAT BRAND "QCV" ONTO LID.

SECTION VIEW - N.T.S.

LANDSCAPE FABRIC TO

3/4" CRUSHED GRAVEL,

4" MINIMUM DEPTH

COVER BOTTOM AND ALL

SIDES OF VALVE BOX

LASCO SNAP-LOK PVC SWING

JOINT W/ MALE BRASS STABILIZER

3/4" QCV USE MODEL G13T-310

1" QCV USE MODEL G13S-310

ELBOW AND SNAP-LOK COLLAR

REBAR STAKES, 1/2" DIAMETER x

24" LONG, TWO REQUIRED

PVC MAINLINE

SEE LEGEND AND

SPECIFICATIONS

NOTE:

USE AN APPROVED, NON-HARDENING, TEFLON ASSEMBLY PASTE ON ALL THREADED FITTINGS.

3/4" ROCK, 1 CUBIC FT.

PVC S x T (1/2") ELL

#4 x 30" REBAR STAKE

STAINLESS STEEL CLAMPS TYPICAL

SCH 80 PVC NIPPLE 1/2"

x LENGTH AS REQUIRED

BRICK SUPPORTS

LATERAL LINE

LANDSCAPE FABRIC

PLASTIC ROUND VALVE BOX WITH BOLT DOWN

COVER, USE STAINLESS BOLT, NUT, AND WASHER.

HEAT BRAND "FV" ONTO LID.

SEE LEGEND FOR SPECIFICATION

BALL FLUSH VALVE WITH BRASS HOSE ADAPTER

FINISHED GRADE IN TURF AREAS

FINISHED GRADE IN SHRUB AREAS

3"

2" MIN.

2" MIN.

SECTION VIEW - N.T.S.

3"

SUBSURFACE DRIP TUBING

LANDSCAPE FABRIC

3/4" ROCK, 1 CUBIC FT.

BRICK SUPPORTS

FINISHED GRADE IN SHRUB AREAS

2" MIN.

VALVE

RAIN BIRD ARV050 AIR / VACUUM RELIEF

HEAT BRAND "ARV" ONTO LID.

FINISHED GRADE IN TURF AREAS

PLASTIC ROUND VALVE BOX, 6" SIZE

1/2" PVC TEE (TxTxT)

HUNTER PLD-050 MPTx17mm BARB (2 REQUIRED)

SECTION VIEW - N.T.S.

SCH. 40 PVC THREADED TEE

OR 90° ELL FITTING, 1/2" SIZE

COATED WIRE STAKE, #GDTS140900,

GPH IRRIGATION PRODUCTS 9" PVC

2" IN SHRUB BEDS

DRIP TUBING SUPPLY OR DISCHARGE

SCH. 40 PVC SLIP X SLIP X 1/2" FIPT

#GFN050600, 1/2" MIPT X 1/2" FIPT X 6" LENGTH

FINISHED GRADE

TEE FITTING, HEADER SIZE BY 1/2"

GPH IRRIGATION PRODUCTS FLEXIBLE NIPPLE,

12" MINIMUM

AMENDED SITE SOIL

1/2" X LENGTH AS REQUIRED

SCH. 80 PVC THREADED NIPPLE,

SIZE PER THE DRAWINGS

SEE PLANTING PLANS

FINISHED GRADE

MULCH LAYER, SEE PLANTING PLANS

1/2" MIPT X 17mm BARB MALE

ADAPTER FITTING, TWO (2) REQUIRED

LENGTH OF DRIP TUBING

ON CENTER INSIDE ENTIRE

EMITTERS INSTALLED 12" ON

DRIP TUBING WITH 0.6 GPH DRIP

SECTION VIEW - N.T.S.

SHRUBS OR GROUND COVERS,

FOR TEE FITTING, ONE (1) FOR 90° ELL

FOR CONNECTIONS AT END RUNS OF TUBING, USE A 90° ELL FITTING AND ONE ADAPTER FITTING FOR CONNECTION.

DRIP TUBING CONNECTION REQUIRED FOR ALL CONNECTIONS BETWEEN DRIP TUBING AND PVC HEADERS.

NOTE:

FOR CONNECTIONS IN THE MIDDLE OF RUNS OF TUBING, USE A TEE FITTING AND

TWO ADAPTER FITTINGS FOR THE CONNECTION.

4" IN TURF AREAS

1 1/4" MINIMUM SIZE, OTHERWISE

HEADER, PVC LATERAL LINE PIPE,

INSTALLED FIVE (5) FEET ON CENTER

TURF, SEE PLANTING PLANS

PLAN…

This is the start of the file's text. The full file is on GovTribe.