W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part2.pdf
PDF 48 MB Posted
- Solicitation number
- W912PL-20-R-0004
About this file
This is a presolicitation notice for a firm fixed-price construction contract. The Department of the Army Corps of Engineers is seeking proposals for the construction of a new Spinal Cord Injury and Community Living Center building and parking structure at the Veterans Affairs Healthcare System campus in San Diego, California. The project includes a 197,000 square foot expansion building with a 50-bed spinal cord injury center and 33-bed community living center, as well as associated clinics, therapy spaces, and site work. An 800-space parking structure is also part of the project. The estimated cost range is $100-250 million. The solicitation will be posted on October 31, 2019 with proposals due January 21, 2020. The North American Industry Classification code is 236220 and the contract has a performance period of three years from notice to proceed. This is an unrestricted procurement with Hubzone price evaluation preference.
Plans - SCICLC - Volume 1 Part 2
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ADMIN BUILDING
BUILDING 13
ADMIN BUILDING
PARKING STRUCTURES 2 & 3
(949) 250-1500
2355 Main Street Suite 220
Irvine, CA 92514
Project No. 215034.00
Pasadena, California 91101
Phone: 626.463.2600 Fax: 626.463.2801
300 N. Lake Avenue, 14th Floor www.ttgcorp.com
STRUCTURAL
ELECTRICAL
MECHANICAL
CIVIL
.TTG
Project Title Project Number
SEISMIC DEFICIENCY -
SCI & CLC HOSPITAL
664-401
Date
Location
Reviewed
EBA
3350 LA JOLLA VILLAGE DR.
SAN DIEGO, CA 92037
09/19/2019
S
I
T
A
E
T
S
L
N
E
C
C
N
O
C
F
O F
I
L
A
R
A
I
T
I
C
R A
D
E H
E
T
REN.: 10-31-19
NO. C-28367
DAVID HUNT
SCI BUILDING 26
PROPOSED
Solicitation Number: W912PL20R0004
(949) 250-1500
2355 Main Street Suite 220
Irvine, CA 92514
Project No. 215034.00
Pasadena, California 91101
Phone: 626.463.2600 Fax: 626.463.2801
300 N. Lake Avenue, 14th Floor www.ttgcorp.com
STRUCTURAL
ELECTRICAL
MECHANICAL
CIVIL
.TTG
Project Title Project Number
SEISMIC DEFICIENCY -
SCI & CLC HOSPITAL
664-401
Date
Location
Reviewed
EBA
3350 LA JOLLA VILLAGE DR.
SAN DIEGO, CA 92037
09/19/2019
S
I
T
A
E
T
S
L
N
E
C
C
N
O
C
F
O F
I
L
A
R
A
I
T
I
C
R A
D
E H
E
T
REN.: 10-31-19
NO. C-28367
DAVID HUNT
MODEL NO. / DESCRIPTION
IRRIGATION MATERIAL LEGEND
FQ T H
SYMBOL
MANUFACTURER DETAILRADIUSPSIFLOW RATE (GPM)
PVC PIPE 3/4" - 3" SCH. 40, SOLVENT WELD WITH SCH. 40 PVC FITTINGS, AS LATERAL LINES INSTALLED 12" BELOW FINISHED GRADE
PAVING, HARDSCAPE, ETC. (OR AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE) INSIDE SLEEVES. SLEEVES UNDER PEDESTRIAN PAVING
PVC PIPE SCH. 40 AS SLEEVING, 2.5 TIMES THE DIAMETER OF PIPE OR WIRE BUNDLE CARRIED (2" MINIMUM SIZE) INSTALL ALL PIPE AND WIRE UNDER
P7079D POLYETHYLENE INSULATED, SOLID COPPER CONDUCTOR IRRIGATION CONTROL WIRE #14UF AWG DIRECT BURIAL (U.L. APPROVED). PILOT
DBR/Y-6 DIRECT BURIAL (I.L. APPROVED) WATER-PROOF WIRE CONNECTORS FOR USE ON ALL WIRE SPLICES AND CONNECTIONS
120 VOLT ELECTRICAL POWER FOR CONTROLLER, PROVIDED BY ELECTRICIAN, VERIFY ACTUAL LOCATION IN FIELD
AS APPROVED
AS APPROVED
N/A
3M
PAIGE ELECTRIC
MODEL LHM15TG1-MEL 11/2" NORMALLY CLOSED, MASTER CONTROL VALVE / FLOW SENSOR / HYDROMETER COMBINATION
975XLS, 2" R/P BACK FLOW PREVENTION DEVICE WITH WYE STRAINER, INSTALL WITH BRASS NIPPLES, UNIONS AND FITTINGS, SIZED PER DEVICE
LASCO
NETAFIM
WILKINS
HYDROPOINT
KSC-XXX-S SWING CHECK VALVE, LATERAL LINE SIZE, INSTALL ONE (1) ON THE DOWNSTREAM SIDE OF EACH RCV WHEN THE RCV IS LOWER THANNDS (K.B.I.)
STRONG BOX SBBC-45SS "SMOOTH TOUCH" STAINLESS STEEL BACK FLOW DEVICE ENCLOSUREV.I.T.
LASCO
AS APPROVED
VXX101N-SC XX" SLO-CLOSE SCH. 80 PVC, TRUE-UNION BALL VALVE WITH SOLVENT WELD SOCKET CONNECTIONS, LINE SIZE PER MAINLINE.
TYPE 'K' COPPER PIPING ROUTED BETWEEN PLANTERS, AND THROUGH BUILDING AND GARAGES. COPPER PIPING SHALL BE DESIGNED BY THEAS APPROVED
AS APPROVED
PVC PIPE 2" - 2 1/2" CL. 315, SOLVENT WELD WITH SCH. 80 PVC FITTINGS, AS MAINLINES INSTALLED 18" BELOW FINISHED GRADEAS APPROVED
RAIN BIRD 30.50 (1.0 TOTAL) 5 FT A,B
11/4" SCH. 40 PVC, GRAY ELECTRICAL CONDUIT FOR FLOW SENSOR / MASTER VALVE WIRES OR CENTRAL CONTROL COMMUNICATION CABLE, PROVIDE
PULL BOX AT A MAXIMUM OF 200 FEET ON CENTER FOR A 3 FOOT WIRE LOOP OR ANY SPLICES. INSTALL INSIDE A STANDARD RECTANGULAR VALVE BOX.
CONNECTION POINT BETWEEN COPPER PIPING (PROVIDED BY PLUMBER) AND PVC IRRIGATION PIPING. COPPER PIPE STUB-OUT SHALL HAVE A LINE
SIZED SWEAT X FIPT COPPER ADAPTER PROVIDED FOR CONNECTION TO THE IRRIGATION PIPING. USE A LINE SIZED X 6" SCH. 80 T.O.E. PVC NIPPLE AND
A LINE SIZED PVC COUPLING FOR THE CONNECTION. VERIFY LOCATION, SIZE AND STUB-OUTS OF COPPER PIPING IN THE FIELD PRIOR TO STARTING WORK.
ALL FITTINGS USED WITH SOLVENT WELD MAINLINE PIPE SHALL BE SCH. 80 PVC FITTINGS, GRAY IN COLOR, AND SIZED TO MATCH THE THR MAINLINE
PIPE. ALL FITTINGS USED WITH SOLVENT WELD LATERAL LINE PIPE SHALL BE SCH. 40 PVC, WHITE IN COLOR, AND SIZED TO MATCH THE LATERAL
LINE PIPE. ALL THREADED PVC NIPPLES SHALL BE SCH. 80 PVC PIPE, DARK GRAY IN COLOR, WITH MOLDED THREADS.
P.R. (TRI.)
N/A
.40, .57, .74, 1.47
.86, 1.34, 1.82, 3.64
40 30 FT
20 FT A,D0.45 IN./HR.
0.45 IN./HR.
1806-SAM 6" POP-UP TURF HEAD W/ MP LCS/RCS/SS530 NOZZLES .22, .44 40 4X15 FT A,D0.47 IN./HR.
THE SPRINKLERS, BUBBLERS OR DRIP EMITTERS. INSTALL WITHIN SPRINKLER / BUBBLER / DRIP ZONES AS REQUIRED TO PREVENT LOW HEAD DRAINAGE.
CHRISTY'S ALL SOLVENT WELD CONNECTIONS FOR BOTH MAINLINE AND LATERAL LINE SHALL BE MADE USING THE TWO-STEP PROCESS OF PRIMER AND SOLVENT
CEMENT. PRIMER SHALL BE LOW VOC "PURPLE PRIMER". MAINLINE SOLVENT CEMENT SHALL BE LOW VOC, "GRAY-HEAVY BODY" CEMENT. LATERAL
LINE SOLVENT CEMENT SHALL BE LOW VOC, "RED HOT BLUE GLUE" CEMENT. USE DAUBERS SIZED AT LEAST ONE-HALF THE SIZE OF THE LARGEST PIPE
BEING JOINED. ALL SOLVENT CEMENTED JOINTS SHALL BE MADE PER THE PIPE AND FITTING MANUFACTURER'S RECOMMENDATIONS.
RAIN BIRD
LASCO
RAIN BIRD
1806-SAM 6" POP-UP TURF HEAD WITH A MP2000-90(Q/T/H)/360 ADJUSTABLE NOZZLE
1806-SAM 6" POP-UP TURF HEAD WITH A MP3000-90(Q/T/H)/360 ADJUSTABLE NOZZLE
1806-SAM 6" POP-UP TURF HEAD WITH A MP1000-90(Q/T/H)/360 ADJUSTABLE NOZZLE
.19, .28, .37, .75 40 14 FT A,D0.45 IN./HR.
CONNECTION BETWEEN XFS DRIP TUBING AND PVC SUPPLY AND DISCHARGE HEADERS SHALL BE MADE USING XF DRIP LINE BARBED FITTINGS, SCH. 40
PVC THREADED FITTINGS, SCH. 80 NIPPLES AND FLEXIBLE NIPPLES. WHEN THE CONNECTION IS AT THE END RUN OF THE TUBING USE A 1/2" SCH. 40 PVC
SHALL BE INSTALLED USING A FITINS-TOOL FOR PROPER INSERTION OF THE FITTING INTO THE TUBING. NO HEATING OF TUBING SHALL BE ALLOWED.
1/2" SCH. 40 PVC BALL VALVE WITH SLIP ENDS AND A LASCO MHT-105 3/4" MHT X 1/2" SPIGOT ADAPTER WITH A LASCO FHT-301 HOSE THREAD CAP, FOR
USE AS A DRIP TUBING FLUSH VALVE. SEE PLANS FOR LOCATIONS. INSTALL INSIDE A 10" ROUND VALVE BOX.
ARV050 AIR/VACUUM RELIEF VALVE INSTALLED WITH A XFD-TFA-075 BARB X BARB X 3/4" FIPT TEE FITTING AND A AND A 3/4" X 1/2" SCH. 40 PVC THREADED
REDUCER BUSHING. INSTALL AIR RELIEF ASSEMBLY AT THE HIGH POINT OF EACH PLANTER. SEE PLANS FOR APPROXIMATE LOCATION AND QUANTITY OF
ARV'S PER DRIP ZONE. USING AN AIR RELIEF LATERAL CONSTRUCTED OF XFD "BLANK" XF TUBING, CONNECT AIR RELIEF VALVE TO ALL DRIP LINE
XFS-06-12 SUBSURFACE DRIP TUBING (COPPER EXTERIOR COLOR) WITH 0.60 GPH, PRESSURE COMPENSATING EMITTERS INTERNALLY INSTALLED IN THE
DRIP EMITTER. DRIP TUBING SHALL BE INSTALLED 2" BELOW FINISHED SOIL GRADE (NOT COUNTING MULCH) AND IN PARALLEL ROWS A MAXIMUM OF 16"
ON CENTER. THE PERIMETER ROW OF DRIP TUBING SHALL BE INSTALLED A MAXIMUM OF 4" FROM THE EDGE OF ANY HARDSCAPE OR TURF EDGE. ALL
SUBSEQUENT INTERIOR ROWS SHALL BE ADJUSTED TO PROVIDE AN EVEN SPACING ACROSS THE PLANTER WITHOUT EXCEEDING 16" MAXIMUM SPACING.
INSTALL 9" PVC COATED GALVANIZED TUBING STAKES A MAXIMUM OF FIVE (5) FEET ON CENTER ALONG THE LENGTH OF THE TUBING. TUBING STAKES
THREADED 90° ELBOW, A 1/2" X LENGTH AS REQUIRED SCH. 80 PVC THREADED NIPPLE, A 1/2" X 6" MIPT X FIPT FLEXIBLE NIPPLE, AND A XFF-MA-050 17mm
BARB X 1/2" MIPT ADAPTER FITTING. WHEN THE CONNECTION IS IN THE MIDDLE OF THE TUBING RUN USE A 1/2" SCH. 40 PVC THREADED TEE FITTING, A
1/2" X LENGTH AS REQUIRED SCH. 80 PVC THREADED NIPPLE, A 1/2" X 6" MIPT X FIPT FLEXIBLE NIPPLE, AND TWO (2) XFF-MA-050 17mm BARB X 1/2" MIPT
ADAPTERS. ALL END RUNS OF TUBING SHALL BE CONNECTED WITH A PVC DISCHARGE HEADER. FLEXIBLE NIPPLES SHALL BE MODEL #GFN050600 AS
PVC SUPPLY AND DISCHARGE HEADERS SHALL BE PVC LATERAL LINE PIPE (AS SHOWN BELOW), 1 1/4" MINIMUM SIZE WITH SCH. 40 PVC FITTINGS.
THESE VINE PLANTINGS. THE CONTRACTOR SHALL INSTALL TWO (2) XB-10PC 1 GPH DRIP EMITTERS PER VINE PLANTING. THESE ADDITIONAL EMITTERS
WHERE VINES ARE PLANTED ON WALLS, FENCES OR COLUMNS WITHIN THE DRIP TUBING ZONES, ADDITIONAL DRIP EMITTERS SHALL BE REQUIRED FOR
SHALL BE PUNCHED DIRECTLY INTO THE DRIP TUBING. EMITTERS SHALL BE INSTALLED USING A XM-TOOL EMITTER INSTALLATION TOOL. EACH DRIP
LOCATE EMITTER OUTLETS DIRECTLY OVER THE ROOT BALL OF THE VINE PLANTING.
REPRESENT THE APPROXIMATE DIRECTION AND SPACING OF THE DRIP TUBING ROWS, SEE ACTUAL SPACING REQUIREMENTS ABOVE AND IN DETAILS.
DRIP TUBING AT 12" O.C. SPACING. DRIP TUBING SHALL BE EQUIPPED WITH COPPER CHIP TECHNOLOGY TO PREVENT ROOT INTRUSION INTO THE
MANUFACTURED BY GPH IRRIGATION PRODUCTS (866) 582-9684.
SHALL BE MODEL #GDTS140900 AS MANUFACTURED BY GPH IRRIGATION PRODUCTS (866) 582-9684. THE HATCH PATTERN SYMBOLS ON THE PLANS
XF SERIES 17mm BARBED FITTINGS FOR ALL CONNECTIONS BETWEEN DRIP TUBING (TUBING-TO-TUBING ONLY). ALL BARBED DRIP TUBING FITTINGS
EMITTER SHALL BE INSTALLED WITH AN 18" LENGTH OF XQ-1/4" DISTRIBUTION TUBING, A TS-025 TUBING STAKE AND A DBC-025 DIFFUSER BUG CAP.
RAIN BIRD
RAIN BIRD
AS APPROVED
RAIN BIRD
LATERALS WITHIN THE ELEVATED AREA. MULTIPLE ARV'S MAY BE REQUIRED PER DRIP TUBING ZONE, SEE PLANS. INSTALL INSIDE A 7" ROUND VALVE BOX.
NO SYMBOL
NO SYMBOL
NO SYMBOL
NO SYMBOL
INSTALL INSIDE A 10" ROUND VALVE BOX.
44LRC 1" QUICK COUPLER VALVE WITH LOCKING VINYL COVER AND A LASCO G13S-218 SWING JOINT. INSTALL INSIDE A 10" ROUND VALVE BOX.RAIN BIRD
RAIN BIRD
RAIN BIRD
RS-500 WIRED RAIN SENSOR, MOUNT IN RGVRSS ENCLOSURE ON THE SIDE OF THE CONTROLLER ENCLOSURE, WIRE TO THE CONTROLLER.RAIN MASTER
A,D
4X30 FT
RAIN BIRD 1806-SAM 6" POP-UP "INDICATOR HEAD" WITH A 10 SERIES VAN NOZZLE (PAINT NOZZLE BRIGHT ORANGE). INSTALL INDICATOR HEAD ON A DISCHARGE
HEADER OF THE DRIP SYSTEM ZONE AND WITHIN SIGHT OF THE DRIP REMOTE CONTROL VALVE. ADJUST VAN NOZZLE TO FULLY CLOSED.
SHALL BE INSTALLED 24" BELOW FINISHED GRADE. SLEEVES UNDER VEHICULAR PAVING SHALL BE INSTALLED 36" BELOW FINISHED GRADE.
NO SYMBOL
NO SYMBOL
AS APPROVED ALL SOLVENT WELD MAINLINES ABOVE 2" IN SIZE SHALL HAVE CONCRETE THRUST BLOCKING INSTALLED AT ALL DIRECTIONAL CHANGES INCLUDING
ELBOWS (45° AND 90°) AND TEES. MAINLINE PIPES UNDER 2" SIZE AND ALL LATERAL LINES DO NOT REQUIRE THRUST BLOCKING.
NO SYMBOL
NO SYMBOL
PLUMBING ENGINEER AND BE SHOWN ON THE PLUMBING PLANS. COPPER PIPING SHALL BE INSTALLED BY THE PLUMBER. COPPER PIPING SHOWN
IS FOR REFERENCE ONLY. VERIFY LOCATION, SIZE AND STUB-OUTS OF COPPER PIPING IN THE FIELD PRIOR TO STARTING WORK.
WIRES SHALL BE RED IN COLOR, COMMON GROUND WIRE SHALL BE WHITE IN COLOR, SPARE WIRES SHALL BE YELLOW IN COLOR. WHERE MULTIPLE
CONTROLLERS ARE USED ON THE PROJECT, EACH CONTROLLER SHALL HAVE A DIFFERENT COLOR FOR PILOT WIRES. THE CONTRACTOR SHALL ROUTE
TWO (2) SPARE CONTROL WIRES (YELLOW) FROM THE CONTROLLER ALONG THE MAINLINE IN ALL DIRECTIONS AWAY FROM THE CONTROLLER. LOOP
SPARE WIRES UP AND INTO EACH VALVE BOX ALONG THE MAINLINE, PROVIDING A 3 FOOT MINIMUM LOOP.
NO SYMBOL
NO SYMBOL
NO SYMBOL
KC-XXX-S SPRING CHECK VALVE, LATERAL LINE SIZE, INSTALL ONE (1) ON THE DOWNSTREAM SIDE OF EACH RCV WHEN THE RCV IS HIGHER THAN
THE SPRINKLERS, BUBBLERS OR DRIP EMITTERS. INSTALL WITHIN SPRINKLER / BUBBLER / DRIP ZONES AS REQUIRED TO PREVENT LOW HEAD DRAINAGE.
NO SYMBOL
ALL VALVE BOXES SHALL BE VB SERIES, PLASTIC TYPE WITH OVERLAPPING LIDS. COVERS FOR BOXES IN TURF AREAS SHALL BE GREEN AND COVERS
FOR VALVE BOXES IN SHRUB AREAS SHALL BE BLACK. ALL BOXES SHALL BE SECURED WITH A RAIN BIRD VB-LOCK-P PENTA HEAD BOLT, WASHER AND
CLIP. BOXES SHALL BE AS SHOWN BELOW:
DESCRIPTION
10" ROUND BOXES
STANDARD RECTANGULAR BOXES
JUMBO RECTANGULAR BOXES
7" ROUND BOXES
VB-10RND
VB-7RND
VB-STD
VB-JMB
TURF AREAS (GREEN)
VB-10RVD-B BODY AND VB-10RNDBKL LID
VB-7RNDBK
VB-STD-B BODY AND VB-STDBKL LID
VB-JMB-B BODY AND VB-JMBBKL LID
SHRUB AREAS (BLACK)
RAIN BIRDNO SYMBOL
THE CONTROLLER SHALL BE GROUNDED USING A #182000 5/8" X 8 FOOT COPPER CLAD GROUND ROD, A #182005 CAST BRONZE ROD CLAMP ANDPAIGE ELECTRICNO SYMBOL
THE REQUIRED LENGTH OF #6AWG BARE, SINGLE STRAND COPPER GROUND WIRE. INSTALL INSIDE A 10" ROUND VALVE BOX.
E,F,G
E,F,G
E,F,G
E,F,G
E,F,G
F,H
F,I
F
WR-01
WR-01
J
K
L
M
N
O,P,Q
Q
N/A
N/A
R
R
S
N/A
N/A
U
N/A
N/A
N/A
R,S,T
T
N/A
N/A
N/A
NDS (K.B.I.)
.23, .33, .42, .78
.40, .57, .74, 1.47
.86, 1.34, 1.82, 3.64
40 30 FT
20 FT
10 FT
A
A0.81 IN./HR.
0.45 IN./HR.
0.45 IN./HR.
.22, .44 40 4X15 FT A0.47 IN./HR.
.19, .28, .37, .75 40 14 FT A0.45 IN./HR.
A
4X30 FT
RAIN BIRD
30.50 (1.0) N/A C
1402 BUBBLER HEAD ON TOP OF A SCH. 80 NIPPLE, INSTALLED BENEATH TREE GRATE
PER DETAIL, EACH SYMBOL REPRESENTS TWO BUBBLERS PER TREE, PLACE BUBBLERS
AT EDGE OF ROOTBALL ON OPPOSITE SIDES OF TREE.
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
RAIN BIRD / HUNTER
1806-SAM 6" POP-UP BUBBLER HEAD WITH A RAIN BIRD 5Q-B STREAM BUBBLER
NOZZLE, EACH SYMBOL REPRESENTS TWO (2) BUBBLERS PER TREE OR PALM, PLACE
BUBBLERS AT EDGE OF ROOT BALL ON OPPOSITE SIDES OF TREE OR PALM, TYPICAL.
ADJUST BUBBLER STREAMS TO WET THE ROOT BALL AND AMENDED SOIL WITHOUT
HITTING THE TRUNK OF THE TREE OR PALM.
1812-SAM 12" POP-UP SHRUB HEAD WITH A MP800SR-90/360 ADJUSTABLE NOZZLE
1812-SAM 12" POP-UP SHRUB HEAD WITH A MP1000-90(Q/T/H)/360 ADJUSTABLE NOZZLE
1812-SAM 12" POP-UP SHRUB HEAD WITH A MP2000-90(Q/T/H)/360 ADJUSTABLE NOZZLE
1812-SAM 12" POP-UP SHRUB HEAD WITH A MP3000-90(Q/T/H)/360 ADJUSTABLE NOZZLE
1812-SAM 12" POP-UP SHRUB HEAD W/ MP LCS/RCS/SS530 NOZZLES
N/A
EFB-CP-PRS-D PRESSURE REGULATING, BRASS REMOTE CONTROL VALVE (RCV), SIZE AS SHOWN (1", 1 1/2" AND 2" SIZES), SET PRS-D
PRESSURE REGULATOR TO PROVIDE THE OPERATING PRESSURE OF THE SPRINKLER / BUBBLER HEAD TO THE HIGHEST OR FARTHEST HEAD
ON THE CONTROL VALVE ZONE. INSTALL THE RCV INSIDE A STANDARD RECTANGULAR VALVE BOX.
EFB-CP-PRS-D DRIP REMOTE CONTROL VALVE, SIZE AS SHOWN (1" AND 1 1/2" SIZES). INSTALL A DISC FILTER AND AN INLINE PRESSURE
REGULATOR ON THE DOWNSTREAM SIDE OF EACH DRIP REMOTE CONTROL VALVE (DRCV). FOR 1" DRCV'S INSTALL A RAIN BIRD LCRBY-100D DISC
FILTER AND A SENNINGER 1" PMR-40-MF PRESSURE REGULATOR. FOR 1 1/2" DRCV'S INSTALL A RAIN BIRD LCRBY-150D DISC FILTER AND A
SENNINGER 1 1/4" PMR-40-HF PRESSURE REGULATOR. USE A 1 1/2" SCH. 40 PVC THREADED COUPLING, A 1 1/2" X 1 1/4" PVC THREADED REDUCER
BUSHING, AND A 1 1/4" X 2" SCH. 80 PVC NIPPLE AS REQUIRED TO CONNECT THE 1 1/4" REGULATOR TO THE DOWNSTREAM SIDE OF THE 1 1/2"
FILTER. INSTALL THE DRCV ASSEMBLY INSIDE A JUMBO RECTANGULAR VALVE BOX.
1806-SAM WITH 1800-EXT SHALL BE USED IN SHRUB AREAS ON ROOF GARDENS W/ NOZZLES ABOVE
W
3/4" HOSE BIB ON RISER WITH VACUUM BREAKER VAS APPROVED
1806-SAM WITH 1800-EXT SHALL BE USED IN SHRUB AREAS ON ROOF GARDENS W/ NOZZLES ABOVE
W
CONTROLLER "A" WTPRO3-C-72-STW WEATHERTRAK ETPRO 3 (72 STATION) CONTROLLER INSTALLED WITHIN A WIDE TOP ENTRY ENCLOSURE.
CONTROLLER "B" WTPRO3-C-12-SWM WEATHERTRAK ETPRO 3 (12 STATION) CONTROLLER INSTALLED WITHIN A STAINLESS STEEL WALL MOUNTED ENCLOSURE.
EACH CONTROLLER IS COMPLETE WITH ONE (1) YEAR OF WEATHERTRAK CENTRAL SERVICE. CONTRACTOR SHALL PROVIDE ONE (1) RAINMASTER PRO-MAX UA
SERIES HAND HELD REMOTE AS PART OF TURN-OVER ITEMS.
975XLS, 11/2" R/P BACK FLOW PREVENTION DEVICE WITH WYE STRAINER, INSTALL WITH BRASS NIPPLES, UNIONS AND FITTINGS, SIZED PER DEVICEWILKINS WR-01
X
OPERATING PRESSURE (PSI)
ZONE AREA (SFT)
VALVE FLOW RATE IN G.P.M.
VALVE SIZE IN INCHES
CONTROLLER LETTER / STATION NUMBER
HYDROZONE NUMBER SEE CHART
IRRIGATION METHOD SEE CHART
ZONE PRECIPITATION RATE (IN./HR.)
LENGTH OF DRIP TUBING
FOR DRIP TUBING ZONES
VALVE CALLOUT LEGEND
NUMBER
DESCRIPTION OF THE HYDROZONE
SHRUBS WITH MP ROTATOR HEADS
2 SHRUBS WITH INLINE DRIP TUBING
3 TURF WITH MP ROTATOR HEADS
4 TREE BUBBLERS
HYDROZONE DESCRIPTION CHART
NUMBER DESCRIPTION OF THE IRRIGATION METHOD
BUBB BUBBLERS
DRIP DRIP TUBING
MPR OVERHEAD MP ROTATORS
IRRIGATION METHOD DESCRIPTION CHART
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
1. ALL LOCAL MUNICIPAL AND STATE LAWS, RULES AND REGULATIONS GOVERNING OR RELATING TO ANY PORTION OF
THIS WORK ARE HEREBY INCORPORATED INTO AND MADE A PART OF THESE SPECIFICATIONS AND THEIR
PROVISIONS SHALL BE CARRIED OUT BY THE CONTRACTOR.
2. THE CONTRACTOR SHALL VERIFY THE LOCATIONS OF ALL EXISTING UTILITIES, STRUCTURES AND SERVICES BEFORE
COMMENCING WORK. THE LOCATIONS OF UTILITIES, STRUCTURES AND SERVICES SHOWN IN THESE PLANS ARE
APPROXIMATE ONLY. ANY DISCREPANCIES BETWEEN THESE PLANS AND ACTUAL FIELD CONDITIONS SHALL BE
REPORTED TO THE OWNER'S REPRESENTATIVE.
3. THE CONTRACTOR SHALL OBTAIN THE PERTINENT ENGINEERING OR ARCHITECTURAL PLANS BEFORE BEGINNING
WORK.
4. THE CONTRACTOR SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED TO PERFORM THE WORK INDICATED HEREIN
BEFORE BEGINNING WORK.
5. THIS DESIGN IS DIAGRAMMATIC. ALL EQUIPMENT SHOWN IN PAVED AREAS IS FOR DESIGN CLARITY ONLY AND IS TO
BE INSTALLED WITHIN PLANTING AREAS.
6. THE CONTRACTOR SHALL NOT WILLFULLY INSTALL ANY EQUIPMENT AS SHOWN ON THE PLANS WHEN IT IS OBVIOUS
IN THE FIELD THAT UNKNOWN CONDITIONS EXIST THAT WERE NOT EVIDENT AT THE TIME THESE PLANS WERE
PREPARED. ANY SUCH CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER'S REPRESENTATIVE
PRIOR TO ANY WORK OR THE IRRIGATION CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR ANY FIELD
CHANGES DEEMED NECESSARY BY THE OWNER.
7. INSTALL ALL EQUIPMENT AS SHOWN IN THE DETAILS AND SPECIFICATIONS. CONTRACTOR SHALL BE RESPONSIBLE
TO COMPLY WITH LOCAL CITY, COUNTY AND STATE REQUIREMENTS FOR BOTH EQUIPMENT AND INSTALLATION.
8. ACTUAL LOCATION FOR THE INSTALLATION OF THE BACKFLOW PREVENTER AND THE AUTOMATIC CONTROLLER IS
TO BE DETERMINED IN THE FIELD BY THE OWNER'S AUTHORIZED REPRESENTATIVE.
9. CONTRACTOR IS TO PROVIDE AN ADDITIONAL PILOT WIRE FROM CONTROLLER ALONG ENTIRETY OF MAIN LINE TO
THE LAST RCV ON EACH AND EVERY LEG OF MAIN LINE. LABEL SPARE WIRES AT BOTH ENDS.
10. ALL PIPE UNDER PAVED AREAS TO BE INSTALLED IN SLEEVING TWICE THE DIAMETER OF THE PIPE CARRIED. SEE
LEGEND FOR TYPE. ALL WIRE UNDER PAVED AREAS TO BE INSTALLED IN A SCH. 40 SLEEVE THE SIZE REQUIRED TO
EASILY PULL WIRE THROUGH. ALL SLEEVES TO BE INSTALLED WITH A MINIMUM DEPTH AS SHOWN ON THE SLEEVING
DETAILS. SLEEVES TO EXTEND AT LEAST 12" PAST THE EDGE OF THE PAVING.
11. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED IN SHRUB OR GROUND COVER AREAS
WHERE POSSIBLE. ALL QUICK COUPLER AND REMOTE CONTROL VALVES TO BE INSTALLED AS SHOWN ON THE
INSTALLATION DETAILS. INSTALL ALL QUICK COUPLER AND REMOTE CONTROL VALVES WITHIN 18" OF HARDSCAPE.
12. ALL HEADS ARE TO BE INSTALLED WITH THE NOZZLE, SCREEN AND ARCS SHOWN ON THE PLANS. ALL HEADS ARE
TO BE ADJUSTED TO PREVENT OVERSPRAY ONTO BUILDINGS, WALLS, FENCES AND HARDSCAPE. THIS INCLUDES, BUT NOT LIMITED TO, ADJUSTMENT OF DIFFUSER PIN OR ADJUSTMENT SCREW, REPLACEMENT OF PRESSURE
COMPENSATING SCREENS, REPLACEMENT OF NOZZLES WITH MORE APPROPRIATE RADIUS UNITS AND THE
REPLACEMENT OF NOZZLES WITH ADJUSTABLE ARC UNITS.
13. CONTRACTOR SHALL INSTALL ADDITIONAL CHECK VALVES TO HEADS AND LATERALS AS REQUIRED TO PREVENT
LOW HEAD DRAINAGE.
14. THE CONTRACTOR SHALL USE PROPER GROUNDING TECHNIQUES FOR GROUNDING THE CONTROLLER AND
RELATED EQUIPMENT PER MANUFACTURERS SPECIFICATIONS. SWEENEY AND ASSOCIATES RECOMMENDS
MEASURING FOR PROPER GROUND AT LEAST ONCE ANNUALLY, AND NECESSARY ADJUSTMENTS MADE TO COMPLY
WITH MANUFACTURER SPECIFICATIONS.
IRRIGATION NOTES
04/27/2018
04/27/2018
09/26/201806/22/2017
1LI001
07/19/2019
UP DN
SCI BUILDING
PROPOSED
X X X X X X X X X X
X
X X X X X X X X X X X X X X X
X
X X
X X
X
X X
X X
X
X X X X
X
X
X
X
X
X
X
X
X
X X X X X X X X
X X
X X
X
X
X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X X
X X
X X
X X
X X
X X
X X
X X
X X
X X
XXXXXXX
11/4"
3/4"
1"
3/4"
1"
1"
3/4"
1"
1"
11/4"
3/4"
1"
1"
11/4"
11/4"
3/4"
1"
1"
3/4"
1"
1"
11/4"
11/2"
3/4"
1"
3/4"
3/4"
1"
3/4"
1"
1"
1"
1"
1"
11/4"
1"
1"
1"
1"
3/4"
3/4"
1"
3/4"
3/4"
1"
1"
3/4"
11/4"
11/4"
3/4" 1" 1" 3/4"
1"
1"
3/4"
1"
3/4"
1"
1"
11/4"
11/4"
3/4"1"
1"
1"
3/4"
1"
1"
3/4"
1"
3/4"
3/4"
1"
1"
11/4"
3/4"
1"
1"
3/4"
1"
3/4"
1"
3/4"
3/4"
1"
11/4"
11/4"
3/4"
3/4"
3/4"
3/4" 1"
1"
3/4"
1"
1"
11/4"
11/4"
3/4"
3/4"
11/4"
11/2"
11/2"
3/4"
1"
1"
1"
3/4"
3/4"
1"
1"
1"
3/4"
1"
3/4"
3/4"
3/4"
1"
3/4" 3/4"
11/4"
3/4" 11/4"
11/4"
3/4"
3/4"
1"
1"
3/4"
1"
1"
3/4"1" 1"
11/4"
2"
3/4"
3/4" 3/4"
1"
3/4"
11/2"
3/4" 3/4"
3/4"
1" 1"3/4" 1" 1"
3/4" 3/4"
11/4"
11/2"
1"
1"
3/4"
3/4"
1"
3/4" 1"
3/4"
11/4"
1"
3/4"
3/4"
1"
1"
3/4"
1"
3/4"
3/4"
1"
11/4"
3/4"
3/4"
11/4"
3/4"
1"
3/4"
3/4"
1"
3/4"
1"
1"1"
3/4"
3/4"
1"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
3/4"
1"
1"
11/4"
11/4"
11/4"
1"
3/4"
1"
3/4"
3/4"
3/4"
11/2"
3/4"
3/4"
1"
1"
3/4" 1"
1"
1"
3/4"
3/4"
11/4"
3/4"
1"
11/2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
1"
1"
1"
11/2"
11/2"
1"
2"
1"
11/4"
11/4"
1"
3/4"
2"
2"
2"
1"
11/4"
3/4"
11/2"
11/2"
11/4"
11/4"
11/4"
11/4"
3/4"
11/4"
11/2"
2"
2"
2"
1"
1"
1"
3/4"
11/2"
11/4"
11/4"
11/4"
1"
3/4"
11/4"
11/2"
1"
1"
3/4"
3/4"
1"
11/2"
1"
11/4"
3/4"
11/2"
2"
2"
3/4"
3/4"
1"
1"
1"
11/4"
11/4"
11/4"
1"
2"
2"
3/4"
1"
1"
11/4"
2"
2"
1"
11/4"
11/4"
11/4"
3/4" 1"
3/4"
1"
3/4"
3/4"
11/4"
3/4"
1"
1"
3/4"
11/2"
11/2"
11/2"
3/4"
3/4"
1"
1"
3/4"
3/4"
11/4"
11/4"
11/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
3/4"
11/4"
2"
2"
1"
1"
1"
1"
1"
3/4"
1"
11/2"
3/4"
3/4"
1"
3/4" 1"
11/4"
11/4"
3/4"
11/4"
11/4"
11/4"
11/2"
3/4"
11/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
11/2"
11/2"
3/4"
3/4"
1"
1"
11/4"
11/4"
3/4"
3/4"
1"
11/4"
3/4"
3/4"
1"
1"
3/4"
3/4"
3/4"
11/4"
11/4"
3/4"
11/2"
3/4"
3/4"
3/4"
11/4"
11/4"
3/4"
1"
1"
1"
1"
3/4"
11/4"
11/4"
2"
2"
11/4"
1"
1"
11/4"
1"
2"
2"
11/4"
11/4"
11/2"
11/2"
3/4"
1"
1"
1"
11/4"
11/4"
2"
2"
1"
1"
1"
11/4"
11/4"
1"
11/4"
3/4"
1"
11/4"
11/4"
3/4"
3/4"
3/4"
1" 1"3/4"
11/4"
1"
11/2"
3/4" 1" 1"
11/4"
3/4" 1"1"
1"
3/4"
3/4" 3/4"
3/4"
1"
1"
11/2"
2"
3/4"
1"1"
3/4"
1"1"
3/4"
1" 1" 11/4" 11/4"
3/4" 1"
3/4"1" 1"3/4" 1" 1"
11/4"
3/4" 1"
1" 11/4"
11/4"
11/2"
2"
1"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
4020100
N
LI
M
IT
O
F W
O
RK
LIMIT OF WORK
PHASE II PART A PARKING STRUCTURE
LIMIT OF WORK
LIM
IT O
F W O
RK
LIMIT OF WORK
LIMIT OF WORK
LIM
IT
O F
W O
RK
SEE SHEET 1-LI404.A
SEE SHEET 1-LI403.A
SEE SHEET 1-LI402.A
SEE SHEET 1-LI405.ASEE SHEET 1-LI401.A
FOR ENLARGEMENT
FOR ENLARGEMENT
FOR ENLARGEMENT
FOR ENLARGEMENT
FOR ENLARGEMENT
SCI TERRACE
PT/OT TERRACE
ATRIUM COURTYARD
ENTRY ROAD
ROSE GARDEN
LIM
IT O
F W O
RK
1. FOR GREEN ROOF
PLANS SEE LI105
2. FOR BALCONY
CONTAINER
PLANTERS SEE
SHEETS LI102-104
NOTES
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
POINT OF CONNECTION (POC) #1 SHALL BE A DOWNSTREAM OF AN EXISTING BACKFLOW.
THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER SIZE
AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT OF
THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE
WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN
USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY
THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER
PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE
MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE
POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE
ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE
LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR
FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED
BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
WATER PRESSURE AT POC: 78 PSI (STATIC)
DESIGN WATER PRESSURE: 56 PSI
MAXIMUM SYSTEM DEMAND: 31 GPM
RESIDUAL WATER PRESSURE: 22 PSI
NOTE B:
CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON
THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE
APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE
REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S
AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL
POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE C:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE D:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE E:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
IRRIGATION POINT OF CONNECTION #1;
REFER TO NOTE "A"
IRRIGATION CONTROLLER "A";
REFER TO NOTE "B"
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI101
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
2ND FLOOR TERRACE
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NO IRRIGATION THIS SHEET
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI102
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
3RD FLOOR TERRACE
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NO IRRIGATION THIS SHEET
CONTAINER PLANTS TO BE HAND
WATERED VIA HOSE BIB BY OTHERS.
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI103
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NO IRRIGATION THIS SHEET
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
CONTAINER PLANTS TO
BE HAND WATERED VIA
HOSE BIB BY OTHERS.
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI104
FD
FD
F E
C
N C
N C
F E
C
F
E
C
F E
C
F E
C
F
E
C
F
E
C
ELEVATOR
LOBBY
5A101
ELEVATOR
LOBBY
RESIDENT
TOILET
5B102
RESIDENT
TOILET
RESIDENT
TOILET
5B103
RESIDENT
TOILET
STAIR 1
5A21
STAIR 1
STAIR 2
5B06
STAIR 2
PENTHOUSE
5B101
PENTHOUSE
PENTHOUSE
5A104
PENTHOUSE
SERVICE
ELEVATOR
LOBBY
5A102
SERVICE
ELEVATOR
LOBBY
SERVICE
STAIR - NO
EXIT
5A105
SERVICE
STAIR - NO
EXIT
STORAGE
5A103
STORAGE
C
O
P
P
E
R
M
A
I N
L
I N
E
3/4"
3/4"
3/4"
3/4"
1"
11/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
3/4"
3/4"
1"
11/4"
11/2"
3/4"
3/4"
3/4"
1"
1"
11/4"
3/4"
3/4"
1"
3/4"
3/4"
11/4"
3/4"
3/4"
11/4"
3/4"
3/4"
2"
2"
2"
2"
2"
2"
11/4"
1"
C
O P
P E
R
M
A I N
L I N
E
C
O
P
P
L
T
E
R
A
L
C
O
P
P
T
E
R
A
L
C
O P
P E
R
L A
T E
R A
L
C
O
P P
E R
L A
T E
R A
L
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
3/4"
3/4"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
5TH FLOOR ROOF TERRACELIMIT OF WORK
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
POINT OF CONNECTION (POC) #2 SHALL BE A 1.5" DOMESTIC DOMESTIC WATER COPPER
LINE. THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER
SIZE AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT
OF THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE
WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN
USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY
THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER
PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE
MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE
POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE
ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE
LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR
FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED
BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
MINIMUM WATER PRESSURE AT POC: 70 PSI (STATIC)
DESIGN WATER PRESSURE: 64 PSI
MAXIMUM SYSTEM DEMAND: 18 GPM
RESIDUAL WATER PRESSURE: 06 PSI
NOTE B:
SYSTEM WAS DESIGNED FOR A MINIMUM REQUIRED STATIC WATER PRESSURE OF 70
PSI. CONTRACTOR SHALL VERIFY EXISTING STATIC WATER PRESSURE PRIOR TO
COMMENCING WORK. IF STATIC WATER PRESSURE IS LESS THAN THE 70 PSI MIN.
REQUIRED PRESSURE THEN CONTRACTOR SHALL NOTIFY THE IRRIGATION
CONSULTANT IMMEDIATELY.
NOTE C:
CONTROLLER "B" SHALL BE INSTALLED IN THE APPROXIMATE LOCATION SHOWN. THE
CONTRACTOR SHALL COORDINATE THE REQUIRED ELECTRICAL POWER SUPPLY AT THIS
LOCATION WITH THE OWNER'S AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF
CONTROLLER AND ELECTRICAL POINT OF CONNECTION SHALL BE CONFIRMED WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE D:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE E:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE F:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE G:
LATERAL LINE PIPING WITHIN BUILDING SHALL BE A TYPE K COPPER AND IS SHOWN FOR
CLARITY ONLY, ACTUAL DESIGN AND ROUTING SHALL BE COMPLETED BY PLUMBING
ENGINEER AND INSTALLED BY PLUMBING CONTRACTOR. EACH STUB-OUT WITHIN EACH
PLANTER SHALL HAVE A COPPER FEMALE ADAPTER FOR THE LANDSCAPE CONTRACTOR
CONNECTION. ALL PIPING THROUGH BUILDING TO EXTERIOR AND THROUGH BUILDING
TO UPPER FLOOR SHALL BE PROVIDED BY PLUMBER.
IRRIGATION POINT OF CONNECTION #2;
REFER TO NOTE "A"
IRRIGATION CONTROLLER "B";
REFER TO NOTE "C"
COPPER PIPING;
REFER TO NOTE "G"
COPPER PIPING LINES HERE ARE IN THE 4TH
FLOOR CEILING PLUMBER WILL PROVIDE A
COPPER TO PVC ADAPTER AT ALL
TERMINATION IN THE PLANTERS.;
REFER TO NOTE "G"
REDUCED PRESSURE PRINCIPLE BACKFLOW
PREVENTER TO BE INSTALLED PER SAN
DIEGO REGIONAL STANDARD DRAWING
WR-01, DETAIL F5 - 1CG503
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI105
UP
X X X X X X X X X X X X
1"
1"
11/4"
1"
1"
1"
1"
3/4"
3/4"
1"
3/4"
3/4"
1"
1"
3/4"
11/4"
11/4"
3/4" 1" 1" 3/4" 1"
1"
3/4"
1"
3/4"
1"
1"
11/4"
11/4"
3/4"1"
1"
1"
3/4"
1"
1"
3/4"
1"
3/4"
3/4"
1"
1"
11/4"
3/4"
1"
1"
3/4"
1"
3/4"
1"
3/4"
3/4"
1"
11/4"
11/4"
3/4"
3/4"
3/4"
3/4" 1"
1"
3/4"
1"
1"
11/4"
11/4"
3/4"
3/4"
11/4"
11/2"
11/2"
3/4"
1"
3/4"
3/4"
1"
1"
3/4"
3/4"
3/4"
3/4"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
2"
1"
11/4"
3/4"
11/2"
11/2"
11/4"
11/4"
11/4"
11/4"
3/4"
11/4"
11/2"
2"
2"
2"
1"
1"
1"
3/4"
11/2"
11/4"
11/4"
11/4"
1"
3/4"
11/4"
11/2"
1"
1"
3/4"
3/4"
1"
11/2"
1"
11/4"
3/4"
11/2"
2"
2"
1"
1"
11/4"
2"
1"
3/4" 1"
3/4"1" 1"3/4" 1" 1"
11/4"
3/4"
1"
1" 11/4"
11/4"
11/2"
2"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
LIM
IT O
F W O
RK
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
POINT OF CONNECTION (POC) #1 SHALL BE A DOWNSTREAM OF AN EXISTING BACKFLOW.
THE CONTRACTOR SHALL VERIFY THE ACTUAL LOCATION, WATER TYPE, METER SIZE
AND WATER PRESSURE IN THE FIELD PRIOR TO STARTING WORK. MEASUREMENT OF
THE STATIC (NO WATER MOVING) WATER PRESSURE IS ACCEPTABLE FOR POTABLE
WATER SYSTEMS WHERE NO PUMP HAS BEEN INDICATED ON THESE PLANS. WHEN
USING RECYCLED WATER, OR ON POTABLE WATER SYSTEMS REQUIRING A PUMP, ONLY
THE MEASUREMENT OF DYNAMIC (WATER MOVING THROUGH THE METER) WATER
PRESSURE, SHALL BE ACCEPTABLE. THE DYNAMIC WATER PRESSURE SHALL BE
MEASURED AT THE MAXIMUM SYSTEM DEMAND AS INDICATED BELOW. IF ANY OF THE
POC INFORMATION SHOWN ON THESE DRAWING IS FOUND TO BE DIFFERENT THAN THE
ACTUAL POC INFORMATION GATHERED IN THE FIELD, IMMEDIATELY NOTIFY THE
LANDSCAPE ARCHITECT AND IRRIGATION CONSULTANT. SHOULD THE CONTRACTOR
FAIL TO VERIFY THE POC INFORMATION AS SHOWN HEREIN, ANY CHANGES REQUIRED
BY LOW PRESSURE OR VOLUME SHALL BE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
WATER PRESSURE AT POC: 78 PSI (STATIC)
DESIGN WATER PRESSURE: 56 PSI
MAXIMUM SYSTEM DEMAND: 31 GPM
RESIDUAL WATER PRESSURE: 22 PSI
NOTE B:
CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON
THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE
APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE
REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S
AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL
POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE C:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE D:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE E:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
IRRIGATION POINT OF CONNECTION #1;
REFER TO NOTE "A"
IRRIGATION CONTROLLER "A";
REFER TO NOTE "B"
CONTRACTOR SHALL CONNECT TO 1"
SUPPLY LINE FROM THE BUILDING TO
INSTALL A HOSE BIB, REFER TO EXACT
LOCATION ON THE PLUMBING PLANS.
(TYP.)
04/27/2018
04/27/2018
09/26/2018 06/22/201707/19/2019
F
D
F
D
FD
DN
F
D
F
D
SCI BUILDING
PROPOSED
X
X X
X X
X
X X
X X
X
X X X X
BUILDING 1
FF = 357.00
PROPOSED SCI BUILDING
1ST FLOOR FF = 347.00
2ND FLOOR FF = 363.00
11/4"
3/4"
1"
3/4"
1"
1"
3/4"
1"
1"
11/4"
3/4"
1"
1"
11/4"
11/4"
3/4"
1"
1"
3/4"
1"
1"
11/4"
11/2"
3/4"
1"
3/4"
3/4"
1"
3/4"
1"
1"
1"
1"
1"
1" 3/4" 1"
3/4"
1"
3/4" 1"
1"
3/4"
2"
2"
2"
1"
11/2"
11/2"
1"
2"
1"
11/4"
11/4"
11/4"
11/2"
1"
1"
3/4"
1"
11/2"
1"
11/4"
3/4"
11/2"
2"
2"
3/4"
3/4"
1"
1"
1"
11/4"
11/4"
11/4"
1"
2"
2"
3/4"
1"
1"
11/4"
2"
2"
1"
11/4"
11/4"
11/4"
3/4" 1"
3/4"
1"
3/4"
3/4"
11/4"
3/4"
1"
1"
3/4"
11/2"
11/2"
11/2"
3/4"
3/4"
1"
1"
3/4"
3/4"
11/4"
11/4"
11/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
3/4"
11/4"
2"
2"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
CONTROLLER "A" SHALL BE OF THE BRAND, MODEL AND STATION SIZE AS INDICATED ON
THE IRRIGATION MATERIALS LEGEND. THE CONTROLLER SHALL BE INSTALLED IN THE
APPROXIMATE LOCATION SHOWN. THE CONTRACTOR SHALL COORDINATE THE
REQUIRED ELECTRICAL POWER SUPPLY AT THIS LOCATION WITH THE OWNER'S
AUTHORIZED REPRESENTATIVE. FINAL LOCATION OF CONTROLLER AND ELECTRICAL
POINT OF CONNECTION SHALL BE CONFIRMED WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE B:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE C:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE D:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
IRRIGATION CONTROLLER "A";
REFER TO NOTE "B"
LIMIT OF WORK
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI402.A
UP DN
FD
FD
UP
DN
SCI BUILDING
PROPOSED
BUILDING 11
FF = 357.00
BUILDING 2
FF = 315.08
3/4"
1"
3/4"
3/4"
3/4"
1"
1"
3/4" 1"
1"
1"
3/4"
3/4"
11/4"
3/4"
1"
11/2"
2"
2"
1"
1"
1"
1"
1"
1"
1"
3/4"
1"
3/4"
2"
2"
11/4"
1"
1"
11/4"
1"
1"
1"
1"
11/4"
11/4"
1"
11/4"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE B:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE C:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
LIMIT OF WORK
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI403.A
SCI BUILDING
PROPOSED
BUILDING 13
FF = 346.69
PROPOSED SCI BUILDING
1ST FLOOR FF = 347.00
2ND FLOOR FF = 363.00
1"
1"
3/4"
1"
1"
3/4" 1"
1"
11/4"
3/4"
3/4"
11/4"
3/4"
1"
3/4"
1"
1"1"
3/4"
3/4"
1"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
3/4"
1"
1"
11/4"
11/4"
11/4"
1"
3/4"
1"
3/4"
3/4"
3/4"
11/2"
2"
2"
2"
2"
2"
2"
2"
2"
1"
3/4"
11/2"
3/4"
3/4"
1"
3/4" 1"
11/4"
11/4"
3/4"
11/4"
11/4"
11/4"
11/2"
3/4"
11/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
11/2"
11/2"
3/4"
3/4"
1"
1"
11/4"
11/4"
3/4"
3/4"
1"
11/4"
3/4"
3/4"
1"
1"
3/4"
3/4"
3/4"
11/4"
11/4"
11/2"
3/4"
3/4"
3/4"
11/4"
11/4"
3/4"
1"
1"
1"
1"
3/4"
11/4"
11/4"
1"
2"
2"
11/4"
11/2"
11/2"
3/4"
1"
1"
1"
11/4"
11/4"
2"
2"
3/4"
1"
11/4"
11/4"
1"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE B:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE C:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
LIM
IT O
F W O
RK
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI404.A
X X X X X X X X
X X
X X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
BUILDING 13
FF = 346.69
ADMIN BUILDING FF = 345.1
1"
1"
3/4"
3/4"
1"
1"
1"
3/4"
1"
3/4"
3/4"
3/4"
1"
3/4" 3/4"
11/4"
3/4" 11/4"
11/4"
3/4"
3/4"
1"
1"
3/4"
1"
1"
3/4" 1"
1"
11/4"
2"
3/4"
3/4" 3/4"
1"
3/4"
11/2"
3/4" 3/4"
3/4"
1" 1"3/4" 1" 1"
3/4" 3/4"
11/4"
11/2"
1"
1"
3/4"
3/4"
1"
3/4" 1"
3/4"
11/4"
1"
3/4"
3/4"
1"
1"
3/4"
1"
3/4"
3/4"
1"
11/4"
3/4"
3/4"
11/4"
1"1"
3/4"
3/4"
1"
2"
2"
2"
2"
2"
2"2"
2"
2"
2"
2"
3/4"
3/4"
1"
3/4" 1"
11/4"
3/4"
3/4"
11/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
3/4"
1"
1"
11/4"
3/4"
3/4"
3/4"
1"
11/4"
11/4"
11/2"
11/2"
3/4"
1"
1"
1"
11/4"
11/4"
2"
2"
3/4"
1"
11/4"
11/4"
3/4"
3/4"
3/4"
1" 1"3/4"
11/4"
1" 11/2"
3/4" 1" 1"
11/4"
3/4" 1"1"
1"
3/4"
3/4" 3/4"
3/4"
1"
1"
11/2"
2"
3/4"
1"1"
3/4"
1"1"
3/4"
1" 1" 11/4" 11/4"
1504 S.COAST HIGHWAY
LAGUNA BEACH, CA 92651
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
201050
N
LIM
IT O
F W O
RK
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
NOTE A:
THESE PLANS ARE DIAGRAMMATIC, THE MAINLINE AND RELATED IRRIGATION
EQUIPMENT IS SHOWN WITHIN THE PAVING FOR CLARITY ONLY. THE ACTUAL LOCATION
OF MAINLINE AND RELATED IRRIGATION EQUIPMENT SHALL BE WITHIN PLANTER AND A
MINIMUM OF 18" OFF ADJACENT HARDSCAPE AND OTHER OBSTACLES, TYPICAL.
NOTE B:
CONTRACTOR SHALL ADJUST ALL HEADS AS REQUIRED TO ACCOMMODATE ANY
VERTICAL OBSTRUCTIONS THAT MAY OCCUR IN THE LANDSCAPE, INCLUDING BUT NOT
LIMITED TO LIGHT POLES, FIRE HYDRANTS, TREES, ETC. WHEN A SLIGHT RELOCATION
OF THE HEAD IS NOT SUFFICIENT TO CLEAR THE OBSTACLE, OR IF IT NEGATIVELY
AFFECTS THE COVERAGE, AN ADDITIONAL HEAD SHALL BE INSTALLED TO PLACE ONE
HEAD ON EITHER SIDE OF THE OBSTACLE. THE NOZZLES OF THESE TWO HEADS SHALL
HAVE ARC PATTERNS THAT ADD UP TO THE ORIGINAL ARC PATTERN OF THE HEAD
INDICATED ON THE PLANS. THE CONTRACTOR SHALL VERIFY ALL HEAD LAYOUT WITH
OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO STARTING WORK.
NOTE C:
THESE PLANS ARE DIAGRAMMATIC, TREE BUBBLERS AND LATERAL LINES ARE SHOWN
WITHIN THE PAVING FOR CLARITY ONLY, THE ACTUAL LOCATIONS SHALL BE WITHIN THE
PLANTER. THE TREE BUBBLERS SHALL BE ALIGNED WITH TREES AS SHOWN ON THE
PLANTING PLANS, AND AS DIRECTED BY OWNER'S AUTHORIZED REPRESENTATIVE. THE
CONTRACTOR SHALL CONFIRM ALL LAYOUT IN FIELD WITH OWNER'S AUTHORIZED
REPRESENTATIVE PRIOR TO STARTING WORK.
LATERAL PIPE SIZE CHART
PIPE SIZE
3/4"
11/4"
11/2"
2"
1"
0-5
GALLONAGE
5-10
10-15
15-25
25-35
04/27/2018
04/27/2018
09/26/2018 06/22/2017
1LI405.A
949 497 8298 T 949 494 2421 F
LANDSCAPE ARCHITECTURE
W H I T I N D E S I G N W O R K S
619 497 2559 : 619 497 2666 fax
7676 Hazard Center Drive, Suite 500, San Diego, CA 92108 architecture and construction services
I HAVE COMPLIED WITH THE CRITERIA OF THE IRRIGATION GUIDELINES AND
APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE
IRRIGATION DESIGN PLAN
HEIGHT AND NOZZLE REQUIRED
INSTALL SPRINKLER HEADS 4" FROM PAVING EDGE IN TURF AREAS.
SECTION VIEW - N.T.S.
DO NOT INSTALL USING SIDE INLET
FINISHED GRADE IN TURF AREAS
INSTALL POP-UP SPRINKLER HEAD FLUSH WITH
AND GROUND COVERS AREAS
ABOVE FINISHED GRADE IN SHRUB
INSTALL POP-UP SPRINKLER HEAD 1/2"
UNDISTURBED SOIL
LATERAL LINE, SEE SPECIFICATIONS
FOR TYPE AND DEPTH REQUIRED
LATERAL x SPRINKLER INLET SIZE
SCH 40 PVC SxSxT TEE FITTING
SIZE AS PER SPRINKLER INLET
LAY LENGTH TO BE 6" MINIMUM
SEE LEGEND FOR BRAND, MODEL, POP-UP
POP-UP SPRINKLER HEAD, SPRAY OR ROTOR,
PRE-ASSEMBLED TRIPLE SWING JOINT,
HUNTER SJ SERIES (OR APPROVED EQUAL)
LANDSCAPE AREA WITHOUT OVERSPRAY ONTO PAVING, FENCES, WALLS OR BUILDINGS.
INSTALL SPRINKLER HEADS PLUMB. ADJUST SPRAYS OR NOZZLE STREAM TO COVER
INSTALL SPRINKLER HEADS 6" FROM PAVING EDGE IN SHRUB AND GROUND COVER AREAS.
INSTALL SPRINKLER HEADS 12" FROM THE FACE OF BUILDING WALLS OR WINDOWS.
NOTE:
1/2"
FINISHED GRADE IN TURF AREAS
C
L
LASCO "SLO-CLOSE" SCH. 80 PVC,
BRICK SUPPORTS,
FINISHED GRADE IN SHRUB AREAS
PVC IRRIGATION MAINLINE,
6" PVC CL. 160 PIPE, LENGTH
ONE CUBIC FOOT OF
3/4" CRUSHED GRAVEL
6"
THREE REQUIRED
TRU-UNION BALL VALVE, SOLVENT
AS REQUIRED, 12" MINIMUM
SEE LEGEND FOR SPECIFICATION
WELD CONNECTIONS. SIZE BALL
SOLVENT WELD CONNECTIONS
VALVE PER THE MAINLINE SIZE
PROVIDE ONE 30" STEEL VALVE
KEY FOR EA. 3 VALVES INSTALLED
2"
AND CAPTIVE STAINLESS STEEL BOLT AND LOC-KIT.
PLASTIC 10" ROUND VALVE BOX WITH T-COVER
HEAT BRAND "BV" ONTO LID.
SECTION VIEW - N.T.S.
FINISHED GRADE IN TURF AREAS
C
L
QUICK COUPLING VALVE, SEE
BRICK SUPPORTS, 3 REQUIRED
FINISHED GRADE IN SHRUB AREAS
SCH 80 PVC SxSxT TEE FITTING, 3"
LEGEND FOR BRAND AND MODEL
MAINLINE x QCV INLET SIZE
2"
AND CAPTIVE STAINLESS STEEL BOLT AND LOC-KIT.
PLASTIC 10" ROUND VALVE BOX WITH T-COVER
HEAT BRAND "QCV" ONTO LID.
SECTION VIEW - N.T.S.
LANDSCAPE FABRIC TO
3/4" CRUSHED GRAVEL,
4" MINIMUM DEPTH
COVER BOTTOM AND ALL
SIDES OF VALVE BOX
LASCO SNAP-LOK PVC SWING
JOINT W/ MALE BRASS STABILIZER
3/4" QCV USE MODEL G13T-310
1" QCV USE MODEL G13S-310
ELBOW AND SNAP-LOK COLLAR
REBAR STAKES, 1/2" DIAMETER x
24" LONG, TWO REQUIRED
PVC MAINLINE
SEE LEGEND AND
SPECIFICATIONS
NOTE:
USE AN APPROVED, NON-HARDENING, TEFLON ASSEMBLY PASTE ON ALL THREADED FITTINGS.
3/4" ROCK, 1 CUBIC FT.
PVC S x T (1/2") ELL
#4 x 30" REBAR STAKE
STAINLESS STEEL CLAMPS TYPICAL
SCH 80 PVC NIPPLE 1/2"
x LENGTH AS REQUIRED
BRICK SUPPORTS
LATERAL LINE
LANDSCAPE FABRIC
PLASTIC ROUND VALVE BOX WITH BOLT DOWN
COVER, USE STAINLESS BOLT, NUT, AND WASHER.
HEAT BRAND "FV" ONTO LID.
SEE LEGEND FOR SPECIFICATION
BALL FLUSH VALVE WITH BRASS HOSE ADAPTER
FINISHED GRADE IN TURF AREAS
FINISHED GRADE IN SHRUB AREAS
3"
2" MIN.
2" MIN.
SECTION VIEW - N.T.S.
3"
SUBSURFACE DRIP TUBING
LANDSCAPE FABRIC
3/4" ROCK, 1 CUBIC FT.
BRICK SUPPORTS
FINISHED GRADE IN SHRUB AREAS
2" MIN.
VALVE
RAIN BIRD ARV050 AIR / VACUUM RELIEF
HEAT BRAND "ARV" ONTO LID.
FINISHED GRADE IN TURF AREAS
PLASTIC ROUND VALVE BOX, 6" SIZE
1/2" PVC TEE (TxTxT)
HUNTER PLD-050 MPTx17mm BARB (2 REQUIRED)
SECTION VIEW - N.T.S.
SCH. 40 PVC THREADED TEE
OR 90° ELL FITTING, 1/2" SIZE
COATED WIRE STAKE, #GDTS140900,
GPH IRRIGATION PRODUCTS 9" PVC
2" IN SHRUB BEDS
DRIP TUBING SUPPLY OR DISCHARGE
SCH. 40 PVC SLIP X SLIP X 1/2" FIPT
#GFN050600, 1/2" MIPT X 1/2" FIPT X 6" LENGTH
FINISHED GRADE
TEE FITTING, HEADER SIZE BY 1/2"
GPH IRRIGATION PRODUCTS FLEXIBLE NIPPLE,
12" MINIMUM
AMENDED SITE SOIL
1/2" X LENGTH AS REQUIRED
SCH. 80 PVC THREADED NIPPLE,
SIZE PER THE DRAWINGS
SEE PLANTING PLANS
FINISHED GRADE
MULCH LAYER, SEE PLANTING PLANS
1/2" MIPT X 17mm BARB MALE
ADAPTER FITTING, TWO (2) REQUIRED
LENGTH OF DRIP TUBING
ON CENTER INSIDE ENTIRE
EMITTERS INSTALLED 12" ON
DRIP TUBING WITH 0.6 GPH DRIP
SECTION VIEW - N.T.S.
SHRUBS OR GROUND COVERS,
FOR TEE FITTING, ONE (1) FOR 90° ELL
FOR CONNECTIONS AT END RUNS OF TUBING, USE A 90° ELL FITTING AND ONE ADAPTER FITTING FOR CONNECTION.
DRIP TUBING CONNECTION REQUIRED FOR ALL CONNECTIONS BETWEEN DRIP TUBING AND PVC HEADERS.
NOTE:
FOR CONNECTIONS IN THE MIDDLE OF RUNS OF TUBING, USE A TEE FITTING AND
TWO ADAPTER FITTINGS FOR THE CONNECTION.
4" IN TURF AREAS
1 1/4" MINIMUM SIZE, OTHERWISE
HEADER, PVC LATERAL LINE PIPE,
INSTALLED FIVE (5) FEET ON CENTER
TURF, SEE PLANTING PLANS
PLAN…