W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part2.pdf

PDF 43 MB Posted

Attached to
Spinal Cord Injury and Community Living Center (SCI/CLC) Building and Parking Structure, Veterans' Affairs Healthcare System, San Diego, California
Solicitation number
W912PL-20-R-0004
Issued by

About this file

This notice announces a competitive solicitation for construction of a new Spinal Cord Injury and Community Living Center (SCI/CLC) Building and Parking Structure at the Veterans Affairs Healthcare System campus in San Diego, California. Work includes construction of a 197,000 square foot SCI/CLC expansion with 50 SCI beds and 33 CLC beds, outpatient clinics, physical and aquatic therapy spaces, and an 800-space parking structure. The project also involves site work, utilities, and infrastructure upgrades. The performance period is 1096 calendar days after notice to proceed. The estimated cost range is $100-250 million. The solicitation will be available on October 31, 2019 with proposals due January 21, 2020. This is an unrestricted procurement with Huber Zone price evaluation preference. The North American Industry Classification code is 236220. Interested parties must register through the System for Award Management and Federal Business Opportunities website to access solicitation documents.

Plans - SCICLC - Volume 2A Part 2

View the file

Other files

File Type Posted
W912PL-20-R-0004_Amendment0012.pdf PDF
W912PL-20-R-0004 Amendment 0011.pdf PDF
W912PL-20-R-0004_Amendment0010.pdf PDF
W912PL-20-R-0004 Amendment 0009.pdf PDF
W912PL20R0004_Amendment0008.pdf PDF
J and A Sole Source redacted Edwards EST3.pdf PDF
J and A Sole Source redacted Schlage Primus.pdf PDF
W912PL-20-R-0004 Amendment 0007.pdf PDF
W912PL20R0004_Amendment0006.pdf PDF
W912PL-20-R-0004_Amendment0005.pdf PDF
W912PLR0004_Amendment0004.pdf PDF
W912PL-20-R-0004_Amendment0003.pdf PDF
W912PL-20-R-0004_Amendment0002.pdf PDF
Sign-In Roster_SiteWalk_VA SD_2019.11.21.pdf PDF
W912PL20R0004 SF-1442_Amend0001 .pdf PDF
W912PL20R0004 SF-30_Amend0001.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part3.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL3_ParkingGarage.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2G_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2B.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part1.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL4_Appendices.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL2_SCICLC1TO4of4.pdf PDF
W912PL-20-R-0004_Specifications_Solicitation_VOL1_SCI-CLCandParkingGarage.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL3..pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2F_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2H.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2A_Part3.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL2..pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part2.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part3.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2E.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL1_Part4.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2D.pdf PDF
W912PL-20-R-0004_Plans_ParkingGarage_Solicitation_VOL1.pdf PDF
W912PL-20-R-0004_Plans_SCICLC_Solicitation_VOL2C_Part1.pdf PDF
Show all 42

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DN

CMU

1 HOUR SMOKE BARRIER

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

CONCRETE

NON RATED

SMOKE PARTITION

FOR PARTITION TYPES SEE

SHEET AE551

WALL LEGEND

HEADWALL / PARTITION

F H

V

RECESSED FIRE EXTINGUISHER CABINET (FEC)

FIRE HOSE VALVE (FHV)

EMERGENCY EYE & SHOWER COMBINATION

EMERGENCY EYE WASH

EWS

EW

FLOOR DRAIN. SEE PLUMBING DRAWINGSFD

CURTAIN TRACK

F E

C

RECESSED MED GAS ALARM PANEL (MGA

M G

A

INTERIOR STOREFRONT/WINDOW NUMBER,

SEE SHEETS AE641 - AE643

DOOR NUMBER

FOR DOOR SCHEDULE, SEE SHEETS

AE701 & AE702

WALL TYPE

FOR PARTITION TYPE, SEE SHEET AE551

1FH6

DASHED LINE INDICATES

ELEMENT OVERHEAD

VERTICAL DATUM

CASEWORK

EXTERIOR STOREFRONT WINDOW NUMBER,

SEE SHEETS AE620 - AE622

1t

PANIC HARDWARE; SEE DOOR HARDWAREPH

DIM. VALUE INDICATES MIN. CLR DIMENSION

REQUIRED, FROM FO FIN. TO FO FIN.

DIM. VALUE INDICATES DIMENSION FROM

F.O.S TO F.O.S

FIRE EXIT HARDWARE; SEE DOOR HARDWAREFHSF1

A U

T O

AUTOMATIC CONTROLS, REFER TO DOOR SCHEDULE

COMMENTS AND SPECIFICATIONS FOR MORE INFO.

A

C

D

B

N

REFER TO SHEET GI FOR GENERAL NOTES

THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN THE FIELD PRIOR TO STARTING CONSTRUCTION.

THE GENERAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, MEDICAL EQUIPMENT, COMMUNICATION, INTERIOR DESIGN, FIRE SPRINKLER, VERTICAL TRANSPORTATION AND FIRE ALARM DRAWING PRIOR TO STARTING CONSTRUCTION.

SEE ELECTRICAL DRAWINGS FOR ALL OUTLETS. PROVIDE FLOOR OUTLETS FOR FREESTANDING CASEWORK.

FOR WALL AND PARTITION TYPES, REFER TO SHEET (AE551).

ALL FURRING WALLS TO BE 2.5" STUD, UNLESS NOTED OTHERWISE. VERIFY WITH STRUCTURAL DRAWINGS.

ALL DIMENSIONS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE.

FOR MISSING DIMENSION AND ANNOTATIONS, REFER TO ENLARGED PLANS. SHEET LOCATION AS NOTED ON CALLOUT.

FOR DOOR TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE700) SERIES

FOR UNITIZED CURTAIN WALL AND EXTERIOR STOREFRONT TYPES AND DETAILS, REFER TO SHEETS IN THE (AE610 & AE620) SERIES.

FOR WINDOW TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE630 & AE640) SERIES.

FOR INTERIOR FINISH INFORMATION, REFER TO FINISH PLANS AND SCHEDULES IN THE (IN) SERIES.

FOR CASEWORK, REFER TO THE ELEVATIONS AND DETAILS IN THE (AE720 & AE730) SSERIES.

FOR MEDICAL EQUIPMENT AND SPECIALTY EQUIPMENT, REFER TO THE EQUIPMENT PLANS IN THE (AQ) SERIES.

FOR ROOM SIGNAGE, REFER TO THE SIGNAGE PLANS IN THE (SG) SERIES AND INTERIOR ELEVATIONS.

REFER TO SHEET GI651 FOR ACCESSIBILITY REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

REFER TO SHEET GI801, GI802, & GI803 FOR TOILET FIXTURE / ACCESSORY MOUNTING HEIGHTS AND ACCESSIBILITY GUIDELINES.

CEILINGS AND SOFFITS: PROVIDE CEILINGS AND SOFFITS AS SHOWN ON THE REFLECTED CEILING PLANS IN (AE110) SERIES.

PROVIDE BACKING PLATES FOR WALL MOUNTED EQUIPMENT, SIGNAGE, ARTWORK, LOCKERS, WHITE BOARDS, AND OVERHEARD FURNITURE. REFER TO SHEETS

IN THE (GI800) SERIES FOR TYPICAL MOUNTING HEIGHTS.

FOR FURTHER DIMENSIONAL INFORMATION WITH REGARDS TO CASEWORK, EQUIPMENT, WALL PROTECTION, TOILET ACCESSORIES, ETC.; REFER TO INTERIOR

ELEVATIONS IN THE (IN) SERIES.

PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, MECHANICAL, ELECTRICAL, FIRE SPRINKLER AND OTHER SUB-CONTRACTORS. FINAL LOCATION TO BE

APPROVED BY ARCHITECT.

PROVIDE 3/4" THICK FIRE RESISTIVE PLYWOOD TO FACE OF SCHEDULE PARTITION AT IDF ROOMS, ELECTRICAL ROOM/CLOSET. EXTEND TO 8'-0" HEIGHT. PAINT

BACKBOARD WHITE WITHOUT COVERING FIRE RATING SYMBOL.

PROVIDE CONTINUOUS FIRE RATED CONSTRUCTION AS SCHEDULED AROUND ALL RECESSED FIXTURES LOCATED IN A FIRE RATED PARTITION. REFER TO (AE551)

FOR ADDITIONAL INFORMATION.

STRUCTURAL INTEGRITY SHALL NOT BE COMPROMISED DUE TO UNFORSEEN CONFLICTS WITH PIPE, DUCT, OR CONDUIT.

MAINTAIN ALL FIRE AND SMOKE BARRIERS, INCLUDING OCCUPANCY SEPARATIONS AS NOTED ON THE FLOOR PLAN, REFER TO UL DESIGN NUMBERS FOR

ADDITIONAL INFORMATION.

FOR TYPICAL STRUCTURAL FIRE PROTECTION REQUIREMENTS AT COLUMNS, REFER TO SHEET (GI100).

FOR INTERIOR STOREFRONT WINDOW TYPES AND SCHEDULES, REFER TO AE640 SERIES.

ALL ENTRY DOORS TO PATIENT ROOMS, RESIDENT ROOMS, BARIATRIC ROOMS TO BE 8" CLEAR FROM FACE TO ADJACENT TOILET WALL TO DOOR FRAME WHERE

THE ADJACENT WALL HAS A SLIDING DOOR.

ALL DOORS OTHER THAN THE CONDITION NO. 27 TO BE 4" FROM ADJACENT WALL U.O.N.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

C

A

A

3.9

3.9

4.5

4.5

6.9

6.9

7.9

7.9

B.9

1.8

1.8

7.6

7.6

CD

CD

CE

CE

C8

C8C7

CA

CA

CC

CC

CHCH

C2 C1

C5

CGCG

CFCF

C4 C66.

SCI NURSE

ADMIN

3B110

SCI NURSE

ADMIN

280 SF

STAIR 3

3B71

STAIR 3

RESIDENT

ROOM

3B123

RESIDENT

ROOM

RESIDENT

BATHROOM

3B123A

RESIDENT

BATHROOM

RESIDENT

ROOM

3B122

RESIDENT

ROOM

NURSE

OFFICE

3B113

NURSE

OFFICE

SOCIAL

WORK

OFFICE

3B117

SOCIAL

WORK

OFFICE

PART C

SEE DRAWING AE061

CONNECTION

VESTIBULE

3B116

CONNECTION

VESTIBULE

R A

M P

M A

X . S

LO

P

E 1:20

R A

M P

M A

X . S

LO

P

E 1:20

RAMP MAX. SLOPE 1:20

EXISTING BUILDING 11

EXPANSION JOINT PER

FLOOR PLANS AND

STRUCTURAL

DRAWINGS, TYP.

1'

2"

CHIEF

OFFICE

3B109

CHIEF

OFFICE

SCI NURSE

ADMIN

3B111

SCI NURSE

ADMIN

EDUCATION

NURSE

OFFICE

3B112

EDUCATION

NURSE

OFFICE

RESIDENT

BATHROOM

3B122A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

3B121A

RESIDENT

BATHROOM

RESIDENT

ROOM

3B121

RESIDENT

ROOM

ISOLATION

RESIDENT

BATHROOM

3B120A

ISOLATION

RESIDENT

BATHROOM

ISOLATION

RESIDENT

ROOM

3B120

ISOLATION

RESIDENT

ROOM

ISOLATION

ANTE ROOM

3B120B

ISOLATION

ANTE ROOM

SOCIAL

WORK

OFFICE

3B118

SOCIAL

WORK

OFFICE

OFFICE

3B114

OFFICE

5.0

EXISTING BUILDING 11

VERTICAL AND

HORIZONTAL

EXPANSION

JOINT

EXPANSION JOINT

PER STRUCTURAL,

TYP. REFER TO

FLOOR PLANS FOR

DETAILS, TYP.

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:0

:4

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

Checker

ENLARGED THIRD FLOOR FRAMING

PLAN - PART D

AE062

664-401

07/19/2019 Author

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGEND

SCALE: 1/8" = 1'-0"

ENLARGED THIRD FLOOR PLAN - PART D

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

DAVID HUNT

Solicitation Number: W912PL20R0004

DNUP

U

U

S

S

Q

Q

M

R

N

P

7.1 8.1

U.2

S.1

S.2

Q.1

15.1

1.2

2.9

4.9

6.8

U.1

11.2

13.1 13.211.4

7.4

P.1

10.2

10.2

SOILED

LINEN

4A176A

SOILED

LINEN

CLEAN

LINEN

STORAGE

4A176B

CLEAN

LINEN

STORAGE

STORAGE

EQUIPMENT

4A111

STORAGE

EQUIPMENT

HOUSE

CARE

4A112

HOUSE

CARE

MEDICATION

4A112A

MEDICATION

NURSE

SUPERVISOR

4A113A

NURSE

SUPERVISOR

HALLWAY

4A113

HALLWAY

RESIDENT

ROOM

4A114

RESIDENT

ROOM

RESIDENT

BATHROOM

4A114A

RESIDENT

BATHROOM

ACTIVITY

ROOM

4A119

ACTIVITY

ROOM

DINING

4A118

DINING

PANTRY

4A118B

PANTRY

RESIDENT

ROOM

4A115

RESIDENT

ROOM

RESIDENT

BATHROOM

4A115A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4A116A

RESIDENT

BATHROOM

HALLWAY

4A122

HALLWAY

RESIDENT

ROOM

4A123

RESIDENT

ROOM

RESIDENT

BATHROOM

4A123A

RESIDENT

BATHROOM

RESIDENT

ROOM

4A124

RESIDENT

ROOM

RESIDENT

BATHROOM

4A124A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4A125A

RESIDENT

BATHROOM

RESIDENT

ROOM

4A125

RESIDENT

ROOM

RESIDENT

ROOM

4A127

RESIDENT

ROOM

RESIDENT

BATHROOM

4A127A

RESIDENT

BATHROOM

LAUNDRY

4A128

LAUNDRY

RESIDENT

ROOM

4A129

RESIDENT

ROOM

RESIDENT

BATHROOM

4A129A

RESIDENT

BATHROOM

MEDICAL

EQUIPMENT

STORAGE

4A133

MEDICAL

EQUIPMENT

STORAGE

RESIDENT

ROOM

4A130

RESIDENT

ROOM

RESIDENT

BATHROOM

4A130A

RESIDENT

BATHROOM

HALLWAY

4A139

HALLWAY

IDF

4A109

IDF

SOILED

UTILITY

4A142

SOILED

UTILITY

ELECTRICAL

4A143

ELECTRICAL

CLEAN

UTILITY

4A141

CLEAN

UTILITY

RESIDENT

ROOM

4A131

RESIDENT

ROOM

RESIDENT

BATHROOM

4A131A

RESIDENT

BATHROOM

DEN

4A136

DEN

RESIDENT

ROOM

4A137

RESIDENT

ROOM

RESIDENT

BATHROOM

4A137A

RESIDENT

BATHROOM

RESIDENT

TOILET

4A135

RESIDENT

TOILET

HAC

4A134

HAC

STAFF

TOILET

4A140

STAFF

TOILET

MEDITATION

'QUIET'

ROOM

4A105

MEDITATION

'QUIET'

ROOM

VISITOR

TOILET

4A106

VISITOR

TOILET

VISITOR

TOILET

4A107

VISITOR

TOILET

MEDITATION/

COUNSELING

4A104

MEDITATION/

COUNSELING

MULTIDISCIP.

OFFICE

4A147

MULTIDISCIP.

OFFICE

HALLWAY

4A165

HALLWAY

ACTIVITIES

COORDINATOR

4A167

ACTIVITIES

COORDINATOR

HALLWAY

4A158

HALLWAY

SOCIAL

WORK

OFFICE

4A166

SOCIAL

WORK

OFFICE

RECREATIONAL

THERAPIST

OFFICE

4A148

RECREATIONAL

THERAPIST

OFFICE

MULTIDISCIP.

OFFICE

4A149

MULTIDISCIP.

OFFICE

PHARMACY

OFFICE

4A151

PHARMACY

OFFICE

COPY ROOM

4A150

COPY ROOM

POD

LEADER

OFFICE

4A152

POD

LEADER

OFFICE

CLERICAL

4A156A

CLERICAL

CLERICAL

4A156B

CLERICAL

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

4A154

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

HALLWAY

4A146

HALLWAY

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

4A155

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

4A157

CLINICAL

SHARED

PHYSICIAN'S

OFFICE

MED.

DIRECTOR'S

OFFICE

4A160

MED.

DIRECTOR'S

OFFICE

MULTIDISCIP.

OFFICE

4A161

MULTIDISCIP.

OFFICE

CONFERENCE

ROOM

4A163

CONFERENCE

ROOM

STAFF

LOUNGE

4A164

STAFF

LOUNGE

WHEELCHAIR

STORAGE

4A110

WHEELCHAIR

STORAGE

PHYSICAL

THERAPY

STORAGE

4A176

PHYSICAL

THERAPY

STORAGE

STAFF

TOILET

4A162

STAFF

TOILET

STAIR 1

4A21

STAIR 1

SOUTH

TERRACE

SOUTH

TERRACE

SHAFT 2

4A143B

SHAFT 2

SHAFT 1

SHAFT 1

SHAFT 3

SHAFT 3

HALLWAY

4A103

HALLWAY

CLR

8' - 2 1/2"

CLR

8' - 2"

KITCHEN

4A118A

KITCHEN

HALLWAY

4A132

HALLWAY

HALLWAY

4A108

HALLWAY

4A109 4A110

4A176

4A153

4A152

4A151

4A149

4A148

4A147

4A105

4A154

4A155

4A157

4A160

4A161

4A164A

4A103B

4A103A

4A158

4A132

4A166

4A167

4A136

4A137 4A131

4A143

4A112A 4A113A

4A133

4A128

4A114

4A130A

4A130

4A131A

4A129

4A127A

4A127

4A123

4A115

4A162 4A21

4A125

4A150

4A164B

4A163C

4A129A

4A137A

4A134

4A163A

4A111

4A114A

4A116

4A123A

4A104

4A135

4A142

4A141

4A106

4A107

4A108

4A125A

4A124A

SERVICE

CHIEF

OFFICE

4A153

SERVICE

CHIEF

OFFICE

4SF5

4SF6

4SF7

4A124

HALLWAY

4A156

HALLWAY

CLR

7' - 9 1/2"

EW2

EW2

EW2

EW2

EW7

EW7

EW7

EW7

EW7

EW7

EW7

PART B

SEE DRAWING AE064

8' - 2" 12' - 1"

3' - 10 "

1/4"

1' - 9 1/4"

3' - 0 3/4"

2SW4

2SW4

FH6B

FH4B

FH6B

FH4B FH6B

FH4B

FH6BFH4B

FH4B

FF4

FH6B

FF4

AW4A

1FHS6

AW6A

AW4A

AW4AT

AW6A

AW6A

AW6A AW6A FH4A

AW4AT

AW6A

AW4A

AW4A

FH6A

AW6A

AW6A

SAW6B

SAW4B

FH6A

SAW4B

AW6A

AW6A

AW4A

FH4A

AW6A

FH6A

AW6A

AW4A

FH4A

FF4AW6A

SF12

EW3

AW6A

AW4AT

AW6A

EW3EW7

1FHS4

1FHS41FHS4

AW6A

AW6A

1FH6

1FH4

1FH61FH6

1FH61FH4

1FHS6

FH6B

FH4B

AW6B

AW6B

AW4B

EW3

1FHS4

AW6B

FH6B

FH4B

FH4B

FH6BFH6B

FH4B

FH6B

FH4B

FH6B

FH6B

FH6A

FH4A

FH6A

AW4A

FH6A

AW6A

FH6A

2FH6

2FH6

2FH4

2SW4

2SW42SW4

FH6B

1FHS6

1FHS4

FH4B

FH6BFH6B 1FHS6

1FHS4 1FH4

1FH4

1FH41FH4

1FH6

1FH4

2SW42SW42SW4

1FH4

AW6A

AW4A

AW6A

AW4A

AW8A

AW4A

AW6A

AW6A

1FHS4

AW4A

AW8A

1FH4

1FH6

2SW4

FF3

1FH4 1FH4

1FH4

1FH4

FH4B

SAW4A

FH4B

FF4

SAW4A AW4A

FH6B

AW6A

AW6A

AW6A

PH4

4A113

08 41 13.A3

4A122A

4A119

RESIDENT

ROOM

4A116

RESIDENT

ROOM

SAW6A

AW6A AW6A

FH4A

AW6A

AW6A

AW6A

AW6A

AW6A

FH4A

SM4

1FH6

SM6

SAW6A

1FHS4

10' - 0" 8'

7"

9'

3"

AW6A

3' - 3 1/2"

8'

2"

1FH6

10' - 11"

10' - 11"

5' - 0"

7'

1/

2"

2' - 11"

/2

C

LR

2'

1/

2"

10' - 0"

1'

/4 " 2' - 10"

1'

0"

9'

7"

1"

10' - 0" 1' - 11"

2'

9"

9' - 11"

9"

14' - 2"

2' - 11"

4' - 7"

/4 " 8'

1/ 4"

8'

1/

4"

3' - 4"

8' - 2" 12' - 1"

8' - 2"

4' - 0"

4' - 10 3/4" 5' - 4 1/2"

11' - 4"

7' - 10 1/4" 11 3/4" 11' - 11"

2' - 5"

1' - 11 3/4"

9' - 9"1' - 10"4' - 10 1/2"

4' - 11"1' - 0"1' - 4 3/4"

2'

5"

7' - 5 1/2"

8'

1/

2"

8'

7'

1/

4"

C

LR

1' - 0 1/4" 15' - 10 3/4"

7"

FF6

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

ALIGN

2' - 0"7' - 3"

1'

/4

2' - 2"

6'

1"

/2

5' - 4"

10' - 0"

4' - 10" 6' - 8"

2' - 9" 10' - 1"

3' - 1 1/4"2' - 10"

4' - 11 1/4"7' - 4 3/4"

4' - 2 1/4"8' - 6 3/4"

3' - 6 1/2"2' - 0 1/4"

2'

6"

2' - 0 1/4"

6'

9'

"4'

2'

0" 2' - 9 3/4"

2' - 0 3/4"

5' - 5 1/4"

1'

8"

3' - 9 3/4"

ALIGN

4"

1'

1"

1' - 3" 10' - 7 3/4"

2' - 3 1/2"

6' - 0 1/2"3' - 5"

4' - 4 1/4"

2' - 8 1/4"

5'

11' - 5 1/2"

8' - 9 1/4"

1'

0"

8'

1/

2"

C

LR

2' - 3 1/4"2' - 4 3/4"

2'

0"

10' - 1"1' - 0"

2'

1/

4" 6'

0"

2'

3"

2' - 1"

2'

1"

A

LI

G N

A

LI

G N

7' - 11"

5' - 9 1/4"

3'

1/

2"1'

1/

2"

8'

9"

2' - 10"

/4

1'

4"

1'

4"

9" 9"

ALIGN

/4

9'

1/

4" 6'

6"

3/

4"

7' - 5 1/4" 3' - 1 1/2"

7' - 3"

1'

9" 12' - 0"

20' - 5"

2' - 11"

/4

9'

0"

8' - 4"

7' - 9"

3' - 5"

5'

6" 2'

3/ 4"

2' - 7"

1/

4"

13' - 3" 4' - 7 1/2"

3'

/4

CLR

8' - 2 1/2"

1'

/4

4' - 0 3/4"

/4

9"

/4

11' - 0 3/4"

3' - 2 3/4"

3' - 8 3/4"

3' - 1 1/2" 5' - 1 1/4"

3' - 11 3/4"

2'

2'

1/

2"

2'

1' - 6 1/4"1' - 6 1/4"

9" 2'

6"

SF16

SF15

REFER TO SHEET AE621 FOR

STOREFRONT SF15 & SF16

ALIGN

5 3/4"2' - 6 3/4"

2' - 3 3/4"

6' - 5" 6' - 6"

10"

4A140

7'

6" 3'

7'

6" 8"

10' - 0"

5' - 5"

9' - 2"

5' - 11" 6' - 7"

2' - 9 1/2"

20' - 0"

10' - 0"

9' - 7"

3' - 11"

13' - 6"

1'

1/

2"

1' - 5 1/2"

3'

1/

2"

1'

1/

4"

4' - 0 1/2"

78.90°

1FHS41FHS4

1FH4

REFER TO SHEET GI FOR GENERAL NOTES

THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN THE FIELD PRIOR TO STARTING CONSTRUCTION.

THE GENERAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, MEDICAL EQUIPMENT, COMMUNICATION, INTERIOR DESIGN, FIRE SPRINKLER, VERTICAL TRANSPORTATION AND FIRE ALARM DRAWING PRIOR TO STARTING CONSTRUCTION.

SEE ELECTRICAL DRAWINGS FOR ALL OUTLETS. PROVIDE FLOOR OUTLETS FOR FREESTANDING CASEWORK.

FOR WALL AND PARTITION TYPES, REFER TO SHEET (AE551).

ALL FURRING WALLS TO BE 2.5" STUD, UNLESS NOTED OTHERWISE. VERIFY WITH STRUCTURAL DRAWINGS.

ALL DIMENSIONS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE.

FOR MISSING DIMENSION AND ANNOTATIONS, REFER TO ENLARGED PLANS. SHEET LOCATION AS NOTED ON CALLOUT.

FOR DOOR TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE700) SERIES

FOR UNITIZED CURTAIN WALL AND EXTERIOR STOREFRONT TYPES AND DETAILS, REFER TO SHEETS IN THE (AE610 & AE620) SERIES.

FOR WINDOW TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE630 & AE640) SERIES.

FOR INTERIOR FINISH INFORMATION, REFER TO FINISH PLANS AND SCHEDULES IN THE (IN) SERIES.

FOR CASEWORK, REFER TO THE ELEVATIONS AND DETAILS IN THE (AE720 & AE730) SSERIES.

FOR MEDICAL EQUIPMENT AND SPECIALTY EQUIPMENT, REFER TO THE EQUIPMENT PLANS IN THE (AQ) SERIES.

FOR ROOM SIGNAGE, REFER TO THE SIGNAGE PLANS IN THE (SG) SERIES AND INTERIOR ELEVATIONS.

REFER TO SHEET GI651 FOR ACCESSIBILITY REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

REFER TO SHEET GI801, GI802, & GI803 FOR TOILET FIXTURE / ACCESSORY MOUNTING HEIGHTS AND ACCESSIBILITY GUIDELINES.

CEILINGS AND SOFFITS: PROVIDE CEILINGS AND SOFFITS AS SHOWN ON THE REFLECTED CEILING PLANS IN (AE110) SERIES.

PROVIDE BACKING PLATES FOR WALL MOUNTED EQUIPMENT, SIGNAGE, ARTWORK, LOCKERS, WHITE BOARDS, AND OVERHEARD FURNITURE. REFER TO SHEETS

IN THE (GI800) SERIES FOR TYPICAL MOUNTING HEIGHTS.

FOR FURTHER DIMENSIONAL INFORMATION WITH REGARDS TO CASEWORK, EQUIPMENT, WALL PROTECTION, TOILET ACCESSORIES, ETC.; REFER TO INTERIOR

ELEVATIONS IN THE (IN) SERIES.

PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, MECHANICAL, ELECTRICAL, FIRE SPRINKLER AND OTHER SUB-CONTRACTORS. FINAL LOCATION TO BE

APPROVED BY ARCHITECT.

PROVIDE 3/4" THICK FIRE RESISTIVE PLYWOOD TO FACE OF SCHEDULE PARTITION AT IDF ROOMS, ELECTRICAL ROOM/CLOSET. EXTEND TO 8'-0" HEIGHT. PAINT

BACKBOARD WHITE WITHOUT COVERING FIRE RATING SYMBOL.

PROVIDE CONTINUOUS FIRE RATED CONSTRUCTION AS SCHEDULED AROUND ALL RECESSED FIXTURES LOCATED IN A FIRE RATED PARTITION. REFER TO (AE551)

FOR ADDITIONAL INFORMATION.

STRUCTURAL INTEGRITY SHALL NOT BE COMPROMISED DUE TO UNFORSEEN CONFLICTS WITH PIPE, DUCT, OR CONDUIT.

MAINTAIN ALL FIRE AND SMOKE BARRIERS, INCLUDING OCCUPANCY SEPARATIONS AS NOTED ON THE FLOOR PLAN, REFER TO UL DESIGN NUMBERS FOR

ADDITIONAL INFORMATION.

FOR TYPICAL STRUCTURAL FIRE PROTECTION REQUIREMENTS AT COLUMNS, REFER TO SHEET (GI100).

FOR INTERIOR STOREFRONT WINDOW TYPES AND SCHEDULES, REFER TO AE640 SERIES.

ALL ENTRY DOORS TO PATIENT ROOMS, RESIDENT ROOMS, BARIATRIC ROOMS TO BE 8" CLEAR FROM FACE TO ADJACENT TOILET WALL TO DOOR FRAME WHERE

THE ADJACENT WALL HAS A SLIDING DOOR.

ALL DOORS OTHER THAN THE CONDITION NO. 27 TO BE 4" FROM ADJACENT WALL U.O.N.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

F H

V

RECESSED FIRE EXTINGUISHER CABINET (FEC)

FIRE HOSE VALVE (FHV)

EMERGENCY EYE & SHOWER COMBINATION

EMERGENCY EYE WASH

EWS

EW

FLOOR DRAIN. SEE PLUMBING DRAWINGSFD

CURTAIN TRACK F

E

C

RECESSED MED GAS ALARM PANEL (MGA

M G

A

INTERIOR STOREFRONT/WINDOW NUMBER,

SEE SHEETS AE641 - AE643

DOOR NUMBER

FOR DOOR SCHEDULE, SEE SHEETS

AE701 & AE702

WALL TYPE

FOR PARTITION TYPE, SEE SHEET AE551

1FH6

DASHED LINE INDICATES

ELEMENT OVERHEAD

VERTICAL DATUM

CASEWORK

EXTERIOR STOREFRONT WINDOW NUMBER,

SEE SHEETS AE620 - AE622

1t

PANIC HARDWARE; SEE DOOR HARDWAREPH

DIM. VALUE INDICATES MIN. CLR DIMENSION

REQUIRED, FROM FO FIN. TO FO FIN.

DIM. VALUE INDICATES DIMENSION FROM

F.O.S TO F.O.S

FIRE EXIT HARDWARE; SEE DOOR HARDWAREFHSF1

A U

T O

AUTOMATIC CONTROLS, REFER TO DOOR SCHEDULE

COMMENTS AND SPECIFICATIONS FOR MORE INFO.

CMU

1 HOUR SMOKE BARRIER

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

CONCRETE

NON RATED

SMOKE PARTITION

FOR PARTITION TYPES SEE

SHEET AE551

WALL LEGEND

HEADWALL / PARTITION

A

C

D

B

N

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:0

:5

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

Checker

ENLARGED FOURTH FLOOR FRAMING

PLAN - PART A

AE063

664-401

07/19/2019 Author

SCALE: 1/8" = 1'-0"

ENLARGED FOURTH FLOOR FRAMING PLAN - PART A

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGEND

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

5 9 11

M

K

H

F

R

N

G

J

L

P

1.2

2.9

4.9

6.8

H.9

J.5

L.1

3.8

3.8

18.1

18.1

17.1

17.1

8.27.2 6.7

11.2 13.1 13.211.4

P.1

M.1

11.6

10.2

5.1

VENDING

AREA

4A170A

VENDING

AREA

PHYSICAL

THERAPY

4A175

PHYSICAL

THERAPY

WARMING

KITCHEN

4A174C

WARMING

KITCHEN

PHYSICAL

THERAPY

4A175A

PHYSICAL

THERAPY

OCCUPATIONAL

THERAPY

4A175D

OCCUPATIONAL

THERAPY

REHABILITATION

THERAPIST

4A175B

REHABILITATION

THERAPIST

MIN CLR

8' - 2"

ELEVATOR

LOBBY

4A101

ELEVATOR

LOBBY

PASSENGER

ELEVATOR

4AP2

PASSENGER

ELEVATOR

4A176

4A172

4SF4

4SF4

SERVICE

ELEVATOR

4AS2

SERVICE

ELEVATOR SERVICE

ELEVATOR

4AS1

SERVICE

ELEVATOR

PASSENGER

ELEVATOR

4AP1

PASSENGER

ELEVATOR

PASSENGER

ELEVATOR

4AP4

PASSENGER

ELEVATOR PASSENGER

ELEVATOR

4AP3

PASSENGER

ELEVATOR

4AP1

4AP2

4AP3

4AP4

4AS1

4AS2

PART A

SEE DRAWING AE063

PART C

SEE DRAWING AE065

2SW4

2SW4

2SW4

2SW4

1FHS6

2SW4

2SW4

2SW4

2SW4

2SW4

AW6A AW4A PH4

PH4

AW4A

FH4AFH4A

4A175

1FHS6

08 41 13.A3

08 41 13.A3

4A174

FH4A

SERVICE

ELEVATOR

LOBBY

4A171

SERVICE

ELEVATOR

LOBBY

MIN CLR

8' - 2"

FH

4A101

4A117

16.1

A

LI

G N

A

LI

G N

A

LI

G N

A

LI

G N

6'

6"

3' - 1"

1' - 0 1/4"

1' - 6 1/4"

14' - 8"

17' - 9"

5'

6" 2'

3/ 4"

3/

4"

3' - 2"

2' - 2"

3' - 9"

4' - 2 1/2"

6' - 1"

7' - 0"

7' - 2"

16' - 3"

1'

3" 1'

3"2' - 5"

1' - 8 1/2"

2'

1/

2"

18' - 6"

A

LI

G N

/2

4'

1" 7'

1/ 2"

/4

ALIGN3' - 2 1/4"

1'

9"

2' - 3"

A

LI

G N

1'

5"

1'

0"

9'

6"

2' - 0" 9' - 0"

A

LI

G N

1'

/2

2' - 0" 10' - 2"

1' - 9 1/4"

1' - 6" 10' - 2"

2' - 0" 10' - 2"

2' - 4"

4' - 10 1/4"

1' - 0"

EW6

EW6

EW6

EW6

3' - 5" 1' - 7"

10' - 7"

4' - 7"

CMU

1 HOUR SMOKE BARRIER

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

CONCRETE

NON RATED

SMOKE PARTITION

FOR PARTITION TYPES SEE

SHEET AE551

WALL LEGEND

HEADWALL / PARTITION

F H

V

RECESSED FIRE EXTINGUISHER CABINET (FEC)

FIRE HOSE VALVE (FHV)

EMERGENCY EYE & SHOWER COMBINATION

EMERGENCY EYE WASH

EWS

EW

FLOOR DRAIN. SEE PLUMBING DRAWINGSFD

CURTAIN TRACK F

E

C

RECESSED MED GAS ALARM PANEL (MGA

M G

A

INTERIOR STOREFRONT/WINDOW NUMBER,

SEE SHEETS AE641 - AE643

DOOR NUMBER

FOR DOOR SCHEDULE, SEE SHEETS

AE701 & AE702

WALL TYPE

FOR PARTITION TYPE, SEE SHEET AE551

1FH6

DASHED LINE INDICATES

ELEMENT OVERHEAD

VERTICAL DATUM

CASEWORK

EXTERIOR STOREFRONT WINDOW NUMBER,

SEE SHEETS AE620 - AE622

1t

PANIC HARDWARE; SEE DOOR HARDWAREPH

DIM. VALUE INDICATES MIN. CLR DIMENSION

REQUIRED, FROM FO FIN. TO FO FIN.

DIM. VALUE INDICATES DIMENSION FROM

F.O.S TO F.O.S

FIRE EXIT HARDWARE; SEE DOOR HARDWAREFHSF1

A U

T O

AUTOMATIC CONTROLS, REFER TO DOOR SCHEDULE

COMMENTS AND SPECIFICATIONS FOR MORE INFO.

REFER TO SHEET GI FOR GENERAL NOTES

THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN THE FIELD PRIOR TO STARTING CONSTRUCTION.

THE GENERAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, MEDICAL EQUIPMENT, COMMUNICATION, INTERIOR DESIGN, FIRE SPRINKLER, VERTICAL TRANSPORTATION AND FIRE ALARM DRAWING PRIOR TO STARTING CONSTRUCTION.

SEE ELECTRICAL DRAWINGS FOR ALL OUTLETS. PROVIDE FLOOR OUTLETS FOR FREESTANDING CASEWORK.

FOR WALL AND PARTITION TYPES, REFER TO SHEET (AE551).

ALL FURRING WALLS TO BE 2.5" STUD, UNLESS NOTED OTHERWISE. VERIFY WITH STRUCTURAL DRAWINGS.

ALL DIMENSIONS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE.

FOR MISSING DIMENSION AND ANNOTATIONS, REFER TO ENLARGED PLANS. SHEET LOCATION AS NOTED ON CALLOUT.

FOR DOOR TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE700) SERIES

FOR UNITIZED CURTAIN WALL AND EXTERIOR STOREFRONT TYPES AND DETAILS, REFER TO SHEETS IN THE (AE610 & AE620) SERIES.

FOR WINDOW TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE630 & AE640) SERIES.

FOR INTERIOR FINISH INFORMATION, REFER TO FINISH PLANS AND SCHEDULES IN THE (IN) SERIES.

FOR CASEWORK, REFER TO THE ELEVATIONS AND DETAILS IN THE (AE720 & AE730) SSERIES.

FOR MEDICAL EQUIPMENT AND SPECIALTY EQUIPMENT, REFER TO THE EQUIPMENT PLANS IN THE (AQ) SERIES.

FOR ROOM SIGNAGE, REFER TO THE SIGNAGE PLANS IN THE (SG) SERIES AND INTERIOR ELEVATIONS.

REFER TO SHEET GI651 FOR ACCESSIBILITY REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

REFER TO SHEET GI801, GI802, & GI803 FOR TOILET FIXTURE / ACCESSORY MOUNTING HEIGHTS AND ACCESSIBILITY GUIDELINES.

CEILINGS AND SOFFITS: PROVIDE CEILINGS AND SOFFITS AS SHOWN ON THE REFLECTED CEILING PLANS IN (AE110) SERIES.

PROVIDE BACKING PLATES FOR WALL MOUNTED EQUIPMENT, SIGNAGE, ARTWORK, LOCKERS, WHITE BOARDS, AND OVERHEARD FURNITURE. REFER TO SHEETS

IN THE (GI800) SERIES FOR TYPICAL MOUNTING HEIGHTS.

FOR FURTHER DIMENSIONAL INFORMATION WITH REGARDS TO CASEWORK, EQUIPMENT, WALL PROTECTION, TOILET ACCESSORIES, ETC.; REFER TO INTERIOR

ELEVATIONS IN THE (IN) SERIES.

PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, MECHANICAL, ELECTRICAL, FIRE SPRINKLER AND OTHER SUB-CONTRACTORS. FINAL LOCATION TO BE

APPROVED BY ARCHITECT.

PROVIDE 3/4" THICK FIRE RESISTIVE PLYWOOD TO FACE OF SCHEDULE PARTITION AT IDF ROOMS, ELECTRICAL ROOM/CLOSET. EXTEND TO 8'-0" HEIGHT. PAINT

BACKBOARD WHITE WITHOUT COVERING FIRE RATING SYMBOL.

PROVIDE CONTINUOUS FIRE RATED CONSTRUCTION AS SCHEDULED AROUND ALL RECESSED FIXTURES LOCATED IN A FIRE RATED PARTITION. REFER TO (AE551)

FOR ADDITIONAL INFORMATION.

STRUCTURAL INTEGRITY SHALL NOT BE COMPROMISED DUE TO UNFORSEEN CONFLICTS WITH PIPE, DUCT, OR CONDUIT.

MAINTAIN ALL FIRE AND SMOKE BARRIERS, INCLUDING OCCUPANCY SEPARATIONS AS NOTED ON THE FLOOR PLAN, REFER TO UL DESIGN NUMBERS FOR

ADDITIONAL INFORMATION.

FOR TYPICAL STRUCTURAL FIRE PROTECTION REQUIREMENTS AT COLUMNS, REFER TO SHEET (GI100).

FOR INTERIOR STOREFRONT WINDOW TYPES AND SCHEDULES, REFER TO AE640 SERIES.

ALL ENTRY DOORS TO PATIENT ROOMS, RESIDENT ROOMS, BARIATRIC ROOMS TO BE 8" CLEAR FROM FACE TO ADJACENT TOILET WALL TO DOOR FRAME WHERE

THE ADJACENT WALL HAS A SLIDING DOOR.

ALL DOORS OTHER THAN THE CONDITION NO. 27 TO BE 4" FROM ADJACENT WALL U.O.N.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

A

C

D

B

N

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:0

:0

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

Checker

ENLARGED FOURTH FLOOR FRAMING

PLAN - PART B

AE064

664-401

07/19/2019 Author

SCALE: 1/8" = 1'-0"

ENLARGED FOURTH FLOOR FRAMING PLAN - PART B

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGEND

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

C

C

A

A

F

E

G

D

3.8

B

A.0

3.9

4.5

6.9

7.9

B.9

E.2

F.1

18.1

19.1

17.1

19.2

18.2

E.3

E.4

8.27.2

6.7

A.4

1.8

20.1

11.6

5.1

7.6

6.10

RESIDENT

ROOM

4B157

RESIDENT

ROOM

RESIDENT

BATHROOM

4B157A

RESIDENT

BATHROOM

HOUSE

CARE

4B137A

HOUSE

CARE

MEDICATION

4B138

MEDICATION

RESIDENT

ROOM

4B156

RESIDENT

ROOM

RESIDENT

BATHROOM

4B156A

RESIDENT

BATHROOM

HALLWAY

4B137

HALLWAY

RESIDENT

ROOM

4B155

RESIDENT

ROOM

RESIDENT

BATHROOM

4B155A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B153

RESIDENT

ROOM

RESIDENT

BATHROOM

4B153A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B152

RESIDENT

ROOM

RESIDENT

BATHROOM

4B151A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B152A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B151

RESIDENT

ROOM

RESIDENT

ROOM

4B147

RESIDENT

ROOM

RESIDENT

BATHROOM

4B147A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B143A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B142

RESIDENT

ROOM

RESIDENT

BATHROOM

4B136A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B142A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B136

RESIDENT

ROOM

ISOLATION

RESIDENT

ROOM

4B135

ISOLATION

RESIDENT

ROOM

ISO.

RESIDENT

TOILET

4B135A

ISO.

RESIDENT

TOILET

ANTE

4B135B

ANTE

ACTIVITY

ROOM

4B145

ACTIVITY

ROOMLAUNDRY

4B133

LAUNDRY

LIVING

ROOM

4B146

LIVING

ROOM

DINING

4B144

DINING

KITCHEN

4B144A

KITCHEN

HALLWAY

4B150

HALLWAY

HALLWAY

4B141

HALLWAY

RECYCLING

COLLECTION

4A172

RECYCLING

COLLECTION

HALLWAY

4B160

HALLWAY

HALLWAY

4B163

HALLWAY

VISITOR

LOUNGE

4B162

VISITOR

LOUNGE

CLEAN

LINEN &

HOUSEKEEPING

4B125

CLEAN

LINEN &

HOUSEKEEPING

BARBER /

BEAUTY

SHOP

4B161

BARBER /

BEAUTY

SHOP

NURSE

SUPERVISOR

4B158

NURSE

SUPERVISOR

BARIATRIC

BEDROOM

4B132

BARIATRIC

BEDROOM

BARIATRIC

BATHROOM

4B132A

BARIATRIC

BATHROOM

STAIR 3

4B71

STAIR 3

HAC

4B126

HAC

MEDICAL

EQUIPMENT

STORAGE

4B127

MEDICAL

EQUIPMENT

STORAGE

SOILED

UTILITY

4B128

SOILED

UTILITY

ELECTRICAL

4B131

ELECTRICAL

STORAGE

EQUIPMENT

4B139

STORAGE

EQUIPMENT

RESIDENT

BATHROOM

4B124A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B123A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B123

RESIDENT

ROOM

ALCOVE

4B122A

ALCOVE

STAFF

TOILET

4B100

STAFF

TOILET

RESIDENT

BATHROOM

4B120A

RESIDENT

BATHROOM

RESIDENT

BATHROOM

4B119A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B119

RESIDENT

ROOM

RESIDENT

ROOM

4B118

RESIDENT

ROOM

RESIDENT

BATHROOM

4B118A

RESIDENT

BATHROOM

BARIATRIC

BATHROOM

4B111A

BARIATRIC

BATHROOM

HALLWAY

4B110

HALLWAY

GARDEN

TERRACE

GARDEN

TERRACE

KITCHEN

4B116A

KITCHEN

MEDICATION

4B106

MEDICATION

NURSE

SUPERVISOR

4B105

NURSE

SUPERVISOR

ANTE

4B109B

ANTE

GARDEN

TERRACE

GARDEN

TERRACE

HAC

4B134

HAC

RESIDENT

ROOM

4B120

RESIDENT

ROOM

PATIENT

TOILET

4B164

PATIENT

TOILET

LIVING

ROOM

4B115

LIVING

ROOM

HALLWAY

4B117

HALLWAY

HALLWAY

4B103

HALLWAY

HALLWAY

4B122

HALLWAY

HALLWAY

4B130

HALLWAY

HOUSE

CARE

4B104

HOUSE

CARE

ISOLATION

BEDROOM

4B109

ISOLATION

BEDROOM

ISO.

PATIENT

TOILET

4B109A

ISO.

PATIENT

TOILET

RESIDENT

BATHROOM

4B108A

RESIDENT

BATHROOM

RESIDENT

ROOM

4B102

RESIDENT

ROOM

RESIDENT

ROOM

4B101

RESIDENT

ROOM

RESIDENT

BATHROOM

4B101A

RESIDENT

BATHROOM

DINING

4B116

DINING

HALLWAY

4B107

HALLWAY

IDF

4B173

IDF

BARIATRIC

BEDROOM

4B111

BARIATRIC

BEDROOM

RESIDENT

ROOM

4B124

RESIDENT

ROOM

ACTIVITY

ROOM

4B121

ACTIVITY

ROOM

PATIENT

TOILET

4B140

PATIENT

TOILET

RESIDENT

ROOM

4B143

RESIDENT

ROOM

HALLWAY

4B154A

HALLWAY

SMOKE

EVACUATION

& STEAM

SHAFT

4B04C

SMOKE

EVACUATION

& STEAM

SHAFT

4B101A

4B100

4B102A

4A172

4B06

4B

4B123

4B71

4B

4B

4B147

4B105

4B164

4B125

4B126

4B127

4B

4B129

4B133

4B

4B158

4B163B

4B122

4B145

4B151

4B152

4B153

4B155

4B156

4B157

4B117

4B163A

4B109B

4B102

4B101

4A170B

4A173

4B131

4B108

4B142

4B

4B

4B150

4B140

4B109

4B132A

4B135

4B135A

4B135C

4B135B

4B147A

4B143A

4B142A

4B136A

4B

6A

4B157A

4B153A

4B155A

4B152A

4B151A

4B108A

4B109A

4B109C

4B123A

4B124A

4B119A

4B120A

4B

1A

4B

4B160A

4B

4B118A

4B134

4B139

4B121

4B110

4B150B

4B132

4B111

FH6B

AW6A

SAW6B

AW4A

AW6A

AW6A

SHAFT 6

2B136B

SHAFT 6

4SF1

4SF2

4W1

4SF3

SHAFT 5

2B116B

SHAFT 5

MIN CLR

8' - 2 1/4"

4B161

PH

9"

CLR

8' - 2 3/4"

EW3

EW3

EW3

EW3

EW3

EW3

EW7

EW7

EW3

EW6

PART B

SEE DRAWING AE064

SF3

SF9

AW6A

FH4B

FH4B

FH4B

AW6A

FH6A

FH4B FH6A

1FHS6

FH4B

FF6

2FH4

2SW4

1FH61FH6

1FHS4 1FHS41FHS4

1FH4

2FH4

2FH4

PH42FH4

1FHS6

1FHS61FHS6

FH4A

AW4A

AW4A

FH6A

AW6A

FH4A

SAW4B

SAW4B

SAW6A

FH6A

AW6A

AW6A

AW4AAW4A

FH6A

AW6A

FH4A

AW6A

AW6A

FF6

FH4A

AW6AAW4A

FH6A

AW4A

AW6A

FH6A

SAW4BSAW4B

SAW4B

FH4A

AW6A

AW6A FH4B

FH4A

PH4

2FH62FH6

2FH6

FH6A

AW4A

AW4A

AW4A

FH4A

FH6A AW4A

AW4A

FH4A

AW6A

AW4A

FH4A

AW6A

FH4A

AW4A

AW4A

FH4B

2SW4

1FHS4FH4B

AW4A

AW6A

1FH4

1FH6

1FH4

1FH4

1FH41FH4

1FH6

1FH4

2SW4

FH6B

FH4B

1FH4

1FH4

FH6B

FH4B

FH6B

FH4B

SM4

AW4A

AW4A

RESIDENT

ROOM

4B108

RESIDENT

ROOM

RESIDENT

BATHROOM

4B102A

RESIDENT

BATHROOM

4B141

08 41 13.A3

08 41 13.A3

08 41 13.A3

08 51 13.A1

4B110A

FF6

1FHS6

1FH4

1FH6

AW6A

FH4B

FH4B

PH4PH4

AW4A

AW6A

1FHS6

AW6A

AW6A

AW6A

SAW6A

FH4B

FH4AFF6

AW6A

1FHS6

SAW6A

SM4

SM6

SM4

SM6

FH6B

FH4A

1FHS4

1FHS6

1FHS4

AW4A

ALIGN

C

LR

8'

2"

3' - 9"

1FH4

CLEAN

UTILITY

4B129

CLEAN

UTILITY

ALIGN

ALIGN

8'

2"

8'

2"

CLR

8' - 2"

ALIGN1' - 0 1/2"

1' - 0 1/2"

12' - 4 1/4"

16.1

2' - 7 1/2"

3' - 6 3/4"

ALIGN

/2

2' - 0 3/4"

4' - 7 3/4"

CLR.

9' - 6"

12' - 5" 6 3/4"

1' - 5 3/4"

2'

1/

4"

8'

1/

2"

9'

3/

4"

5' - 3"

1' - 0 1/2"

5' - 11 3/4"

12' - 1 1/4"

A

LI

G N

/2

/2

1'

3/

4"

A

LI

G N

7"2' - 4 3/4"

2' - 3 3/4"

7"

12' - 2"

/4

17' - 0 1/4"

1/2"

/4

1' - 3"

4'

1/

2"

1' - 6"

/2

1'

9" 3' - 2 1/4"

ALIGN

7' - 1" 4' - 1 1/2"

8 3/4"

9 1/2"

9"

2' - 1 3/4"

/2 " 1' - 7 1/2" 2' - 1 1/2"

1' - 5 1/4"

8'

2"

1' - 7 1/2"

ALIGN

5' - 2 3/4"

3' - 6"

8'

2"

12' - 1"

1' - 6" 3' - 1"

4'

3/

4"

6'

3/

4"

5' - 4 1/4"

4' - 11"

5'

8"

2'

3/

4"

4' - 6"

1' - 1"

8' - 5 1/4"

7' - 2 1/4"

8'

/4

11' - 10 3/4"

4' - 9"

2'

2' - 1 1/2"

11"

11 1/4"

8'

2"

7"

12' - 1"

1' - 2"

2' - 8" 6"

1' - 6 1/2"

ALIGN

14' - 0 1/4"

9' - 2 1/2"9'

1/

4" 5'

3/ 4"

3' - 1"

8'

3/

4" 6'

3/ 4"

3' - 1 1/2" 3' - 1 1/4"

2'

0"

1' - 9 1/2"

8'

9 3/4"

/2

5"

1'

/2

1' - 5 1/4"

ALIGN

1' - 2 1/4"

2' - 10 1/4"

8' - 4"

4"

/2

/4

2' - 5 1/2" 1' - 7 1/2"

11' - 11"

10' - 4"

2' - 1 1/4"

8'

3/

4" 6'

3/ 4"

3' - 5 3/4"

9"9"

1'

3" 1'

3"

9" 9"1'

3"

1'

3"

2'

6"

5' - 1 1/2" 13' - 7 1/4"

10' - 0 3/4" C

LR

/2

8'

2"

ALIGN

8'

3/

4" 6'

3/ 4"

8' - 5" 11' - 11"

3' - 4"

18' - 8 1/2"

8' - 5"

7'

1/

2" 7'

4"

1'

1/

2"

9' - 8"

7' - 6 3/4"

8' - 4" 12' - 1"

3' - 10"

8'

3/

4" 5'

/2

11' - 10 1/2"

8'

3/

4"

4' - 1"

12' - 1"

8' - 2"

8'

1/

4"

6'

3/

4"

8' - 4"

12' - 2"

2"

6'

1/

4" 8'

1/ 4"

8' - 4"

12' - 0"

5'

8'

1/

4"

ALIGN

C

LR

C

LR

C

LR

C

LR

10' - 4" 3' - 1" 8' - 6 1/2"

6'

3" 7'

1/ 2"

6' - 2 1/4"

7' - 10"

6'

1/

2"

7'

1/

2"

12' - 5"

8' - 4"

7' - 9 3/4"

8'

1/

4"

6' - 4" 8' - 5"

9' - 0"

11 1/2" 4' - 0"

14' - 7"

5" 9' - 4 1/4"

8' - 3 1/2" 7' - 0"

3' - 6" 10' - 4 1/4"

A

LIG

N

8'

6" 7'

7"

11' - 3 1/2"

9" 9"

1'

3" 1'

3"

9" 9"

1'

3" 1'

3"

1' - 2 1/2"

8 3/4"

1'

3"

1' - 3"

1'

4"

9"

1' - 2 1/4"

1'

3/

4"

3' - 1 1/4" 2' - 11 1/2"

1' - 0"

1'

0"

3' - 5 3/4"

9 3/4"

EW12

EW12

2'

1/

2"

EW3

4' - 9"

10' - 3"

1' - 7 3/4"

2' - 9"

9' - 9"

12' - 11 3/4"

11' - 0 1/2"

16' - 11 1/2"

1' - 5 1/2"

6' - 3"

3' - 8"

3' - 10 3/4"

3' - 2 1/2"

1'

3/

4"

11 1/4"

2'

3/

4"

1'

6"

2FH4

2FH4

2FH4

2FH4

2FH4

FF4

FF3

CMU

1 HOUR SMOKE BARRIER

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

CONCRETE

NON RATED

SMOKE PARTITION

FOR PARTITION TYPES SEE

SHEET AE551

WALL LEGEND

HEADWALL / PARTITION

F H

V

RECESSED FIRE EXTINGUISHER CABINET (FEC)

FIRE HOSE VALVE (FHV)

EMERGENCY EYE & SHOWER COMBINATION

EMERGENCY EYE WASH

EWS

EW

FLOOR DRAIN. SEE PLUMBING DRAWINGSFD

CURTAIN TRACK F

E

C

RECESSED MED GAS ALARM PANEL (MGA

M G

A

INTERIOR STOREFRONT/WINDOW NUMBER,

SEE SHEETS AE641 - AE643

DOOR NUMBER

FOR DOOR SCHEDULE, SEE SHEETS

AE701 & AE702

WALL TYPE

FOR PARTITION TYPE, SEE SHEET AE551

1FH6

DASHED LINE INDICATES

ELEMENT OVERHEAD

VERTICAL DATUM

CASEWORK

EXTERIOR STOREFRONT WINDOW NUMBER,

SEE SHEETS AE620 - AE622

1t

PANIC HARDWARE; SEE DOOR HARDWAREPH

DIM. VALUE INDICATES MIN. CLR DIMENSION

REQUIRED, FROM FO FIN. TO FO FIN.

DIM. VALUE INDICATES DIMENSION FROM

F.O.S TO F.O.S

FIRE EXIT HARDWARE; SEE DOOR HARDWAREFHSF1

A U

T O

AUTOMATIC CONTROLS, REFER TO DOOR SCHEDULE

COMMENTS AND SPECIFICATIONS FOR MORE INFO.

REFER TO SHEET GI FOR GENERAL NOTES

THE GENERAL CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND MEASUREMENTS IN THE FIELD PRIOR TO STARTING CONSTRUCTION.

THE GENERAL CONTRACTOR SHALL COORDINATE WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, MEDICAL EQUIPMENT, COMMUNICATION, INTERIOR DESIGN, FIRE SPRINKLER, VERTICAL TRANSPORTATION AND FIRE ALARM DRAWING PRIOR TO STARTING CONSTRUCTION.

SEE ELECTRICAL DRAWINGS FOR ALL OUTLETS. PROVIDE FLOOR OUTLETS FOR FREESTANDING CASEWORK.

FOR WALL AND PARTITION TYPES, REFER TO SHEET (AE551).

ALL FURRING WALLS TO BE 2.5" STUD, UNLESS NOTED OTHERWISE. VERIFY WITH STRUCTURAL DRAWINGS.

ALL DIMENSIONS ARE TO FACE OF STUD (F.O.S.) UNLESS NOTED OTHERWISE.

FOR MISSING DIMENSION AND ANNOTATIONS, REFER TO ENLARGED PLANS. SHEET LOCATION AS NOTED ON CALLOUT.

FOR DOOR TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE700) SERIES

FOR UNITIZED CURTAIN WALL AND EXTERIOR STOREFRONT TYPES AND DETAILS, REFER TO SHEETS IN THE (AE610 & AE620) SERIES.

FOR WINDOW TYPES AND SCHEDULES, REFER TO SHEETS IN THE (AE630 & AE640) SERIES.

FOR INTERIOR FINISH INFORMATION, REFER TO FINISH PLANS AND SCHEDULES IN THE (IN) SERIES.

FOR CASEWORK, REFER TO THE ELEVATIONS AND DETAILS IN THE (AE720 & AE730) SSERIES.

FOR MEDICAL EQUIPMENT AND SPECIALTY EQUIPMENT, REFER TO THE EQUIPMENT PLANS IN THE (AQ) SERIES.

FOR ROOM SIGNAGE, REFER TO THE SIGNAGE PLANS IN THE (SG) SERIES AND INTERIOR ELEVATIONS.

REFER TO SHEET GI651 FOR ACCESSIBILITY REQUIREMENTS.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

REFER TO SHEET GI801, GI802, & GI803 FOR TOILET FIXTURE / ACCESSORY MOUNTING HEIGHTS AND ACCESSIBILITY GUIDELINES.

CEILINGS AND SOFFITS: PROVIDE CEILINGS AND SOFFITS AS SHOWN ON THE REFLECTED CEILING PLANS IN (AE110) SERIES.

PROVIDE BACKING PLATES FOR WALL MOUNTED EQUIPMENT, SIGNAGE, ARTWORK, LOCKERS, WHITE BOARDS, AND OVERHEARD FURNITURE. REFER TO SHEETS

IN THE (GI800) SERIES FOR TYPICAL MOUNTING HEIGHTS.

FOR FURTHER DIMENSIONAL INFORMATION WITH REGARDS TO CASEWORK, EQUIPMENT, WALL PROTECTION, TOILET ACCESSORIES, ETC.; REFER TO INTERIOR

ELEVATIONS IN THE (IN) SERIES.

PROVIDE ACCESS PANELS AS REQUIRED BY PLUMBING, MECHANICAL, ELECTRICAL, FIRE SPRINKLER AND OTHER SUB-CONTRACTORS. FINAL LOCATION TO BE

APPROVED BY ARCHITECT.

PROVIDE 3/4" THICK FIRE RESISTIVE PLYWOOD TO FACE OF SCHEDULE PARTITION AT IDF ROOMS, ELECTRICAL ROOM/CLOSET. EXTEND TO 8'-0" HEIGHT. PAINT

BACKBOARD WHITE WITHOUT COVERING FIRE RATING SYMBOL.

PROVIDE CONTINUOUS FIRE RATED CONSTRUCTION AS SCHEDULED AROUND ALL RECESSED FIXTURES LOCATED IN A FIRE RATED PARTITION. REFER TO (AE551)

FOR ADDITIONAL INFORMATION.

STRUCTURAL INTEGRITY SHALL NOT BE COMPROMISED DUE TO UNFORSEEN CONFLICTS WITH PIPE, DUCT, OR CONDUIT.

MAINTAIN ALL FIRE AND SMOKE BARRIERS, INCLUDING OCCUPANCY SEPARATIONS AS NOTED ON THE FLOOR PLAN, REFER TO UL DESIGN NUMBERS FOR

ADDITIONAL INFORMATION.

FOR TYPICAL STRUCTURAL FIRE PROTECTION REQUIREMENTS AT COLUMNS, REFER TO SHEET (GI100).

FOR INTERIOR STOREFRONT WINDOW TYPES AND SCHEDULES, REFER TO AE640 SERIES.

ALL ENTRY DOORS TO PATIENT ROOMS, RESIDENT ROOMS, BARIATRIC ROOMS TO BE 8" CLEAR FROM FACE TO ADJACENT TOILET WALL TO DOOR FRAME WHERE

THE ADJACENT WALL HAS A SLIDING DOOR.

ALL DOORS OTHER THAN THE CONDITION NO. 27 TO BE 4" FROM ADJACENT WALL U.O.N.

17.

18.

19.

20.

21.

22.

23.

24.

25.

26.

27.

28.

29.

A

C

D

B

N

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:0

:1

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

Checker

ENLARGED FOURTH FLOOR FRAMING

PLAN - PART C

AE065

664-401

07/19/2019 Author

SCALE: 1/8" = 1'-0"

ENLARGED FOURTH FLOOR FRAMING PLAN - PART C

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGEND

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

UP

F E

C

UP

3 4 5 6 7 8 9 10

M

N

P

Q

R

T

U

V

S

(E)

MECHANICAL

ROOM

BA106

(E) DRIVERS

TRAINING

BA103

(E)

ELEVATOR

P-1

(E)

ELEVATOR

P-2

(E) STAIR

NO.1

ST-1

(E) TOILET

BA104

AE100F

3' - 0" 8' - 6"

D20

COORDINATE EXTENT OF SITE

DEMOLITION WITH NEW CONSTRUCTION

PER CIVIL SHEET 1CG121

D1 D10

D3

D11

D2

D2

D3

D10 D3

D2

D1

D10

D2

D4

D20 D21

(E) TUNNEL

D1

D1

LI

M

IT

O

F W

O R

K

LIMIT OF WORK

LIMIT OF WORK

LI

M

IT

O

F W

O R

K

LIMIT OF WORK

LIMIT OF WORK

LINE OF PROPOSED NEW RETAINING

WALL, SEE SHEET AE101E

AE325

AE325

AE325

3 4 5 6 7

M

N

P

Q

R

T

U

V

S

ELEVATOR

MACHINE

ROOM

(SERVES P-1

& P-2)

11 -002

VESTIBULE

11 -001

(E) DRIVERS

TRAINING

BA103

(E)

MECHANICAL

ROOM

BA106

(E) TOILET

BA104

(E)

ELEVATOR

VESTIBULE

CB-1

(E) STAIR

NO.1

ST-1

(E)

ELEVATOR

P-1

(E)

ELEVATOR

P-2

ELEVATOR

MACHINE

ROOM

(SERVES S3

& S4

11-003

11-002

11-003

5' - 0" ±

6'

5"

3'

8"

3'

1FHS6

1FHS6

1FHS6

1FHS6

1FHS6

FF3FF3

REFER TO 1/AE101E FOR NEW SCI

BUILDING CONNECTOR

(E) TUNNEL

CONNECTOR

VESTIBULE

C101

CONNECTOR

VESTIBULE

SERVICE

VESTIBULE

C102

SERVICE

VESTIBULE

SERVICE

STAIR

C103

SERVICE

STAIR

SERVICE

ELEVATOR

S4

SERVICE

ELEVATOR

SERVICE

ELEVATOR

S3

SERVICE

ELEVATOR

MOMUMENTAL

ELEVATOR

PIT

MOMUMENTAL

ELEVATOR

PIT

COORDINATE EXTENT OF SITE

DEMOLITION WITH NEW CONSTRUCTION

PER CIVIL SHEET 1CG121

LIMIT OF WORK

LIMIT OF WORK

LIMIT OF WORK

LI

M

IT

O

F W

O R

K

LIMIT OF WORK

1.

2.

3.

4.

5.

6.

7.

8.

CONFIRM ALL EXISTING AND NEW CONDITIONS WITH THE CONTRACT DOCUMENTS. NOTIFY ARCHITECT IMMEDIATELY IN WRITING OF ALL DISCREPANCIES OR CONFLICTS. DIRECTION SHALL BE GIVEN BY ARCHITECT. IF CONTRACTOR PROCEEDS WITHOUT DIRECTION FROM ARCHITECT, IT SHALL BE AT CONTRACTOR'S RISK, AND CONTRACTOR SHALL

BE RESPONSIBLE FOR ALL REQUIRED CORRECTIVE ACTION.

MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF THE ELECTRICAL AND MECHANICAL WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND THE CONSULTANT'S DRAWINGS, SHALL BE BROUGHT TO THE RESIDENT ENGINEER'S ATTENTION FOR CLARIFICATION AND WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE GENERAL CONTRACTOR AT HIS OWN EXPENSE, AND AT NO EXPENSE TO THE OWNER OR ARCHITECT.

VISIT JOB SITE PRIOR TO BEGINNING WORK AND VERIFY ALL DIMENSIONS AND CONDITIONS.

WHERE WORK OR EQUIPMENT IS INDICATED "N.I.C." (NOT IN CONTRACT) ON THE DRAWINGS, SUCH WORK AND/OR EQUIPMENT SHALL BE PROVIDED BY OTHERS. CONTRACTOR SHALL COORDINATE AND COOPERATE TO EFFECT

SUCH INSTALLATION.

THE CONTRACTOR SHALL PROTECT ALL FINISHED WORK AND SURFACES FROM DAMAGE DURING THE COURSE OF WORK AND SHALL REPLACE AND/OR REPAIR ALL DAMAGE CAUSED BY CONTRACTOR OR SUB-CONTRACTOR

PERSONNEL.

UPON COMPLETION OF WORK, ALL CONSTRUCTION AREAS SHALL BE LEFT BROOM CLEAN AND FREE FROM DEBRIS.

VERIFY POINTS OF CONNECTION, INCLUDING SIZES AND LOCATIONS AND ALL OTHER REQUIRED OPERATING CRITERIA

WITH EQUIPMENT MANUFACTURER.

COORDINATE THE LOCATION AND TYPE OF ALL ACCESS PANELS REQUIRED FOR ACCESSING MECHANICAL, PLUMBING, AND ELECTRICAL AND OTHER BUILDING SYSTEMS WITH ARCHITECT.

FOR ADDITIONAL DEMOLITION NOTES REFER TO DRAWING GI006

PROVIDE CONSTRUCTION BARRIERS TO SEPARATE AREAS UNDER CONSTRUCTION

FROM ADJACENT AREAS.

AIR QUALITY AND INFECTION CONTROL DURING CONSTRUCTION TO COMPLY WITH VA

STANDARDS & REQUIREMENTS AS OUTLINED IN PROJECT MANUAL AND ON DRAWINGS.

DURING CONSTRUCTION PROVIDE CONTINUOUS AND UNOBSTRUCTED EXIT PATH TO

EXISTING EXIT CORRIDORS AND EXIT STAIRS AT ALL TIMES.

AT ALL AREAS REQUIRED TO BE DEMOLISHED BEYOND THE AREA OF RENOVATION,

CONTRACTOR SHALL PATCH, PAINT AND REPAIR ALL FINISH SURFACES, AND REINSTALL

ANY CEILINGS, DUCTS OR LIGHT FIXTURES REQUIRED TO BE REMOVED DURING

DEMOLITION TO RESTORE TO ORIGINAL CONDITION.

FOR ADDITIONAL SCOPE OF DEMOLITION, SEE STRUCTURAL AND MECHANICAL

DRAWINGS.

FOR DEMOLITION OF LIGHTING FIXTURES, HVAC REGISTERS AND OTHER CEILING

DEVICES SEE MECAHNICAL, ELECTRICAL AND PLUMBING DRAWINGS.

DEMOLISH / REMOVE EXISTING MATERIALS, ITEMS OR FINISHES AS NECESSARY TO

PERFORM NEW WORK.

REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONL

INFORMATION.

COORDINATE EXTENT OF DEMOLITION / REMOVAL WITH NEW WORK.

FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS.

N

BUILDING 11

SCI BUILDING

D1

D2

D3

D4

D5

D6

D7

D8

D9

D11

D12

D13

D14

D15

D16

DEMOLITION KEYNOTES

EXISTING FLOORING AND BASE TO BE REMOVED, COORDINATE

SAW-CUTTING AND PATCHING OF FLOOR SLAB PER

REQUIREMENTS OF NEW ELEVATOR MACHINE ROOM

EXISTING WALL TO BE REMOVED. CONTRACTOR EXERCISE

EXTREME CARE WHEN DEMOLISHING EXISTING PARTITION TO

PROTECT IN PLACE EXISTING PIPING LOCATED INSIDE

PARTITIONS

EXISTING DOOR, DOOR FRAME, TRANSOM, THRESHOLD AND

HARDWARE TO BE REMOVED

PARTIALLY SAW CUT EXISTING CONCRETE WALL TO THE

EXTENT REQUIRED TO INSTALL NEW DOOR OPENING, SEE

STRUCTURAL SHEETS

EXISTING STEEL COLUMN TO BE REMOVED PER STRUC.

SHEETS

EXISTING WINDOW AND FRAME TO BE REMOVED, COORDINATE

EXTENT OF DEMOLITION WITH FLOOR PLAN

EXISTING SLIDING DOOR, DOOR FRAME, TRANSOM,

THRESHOLD AND HARDWARE TO BE REMOVED

EXISTING METAL PANEL WALL AND COLUMN EXTENSION TO BE

REMOVED

PORTION OF EXISTING FINISH FLOOR TO BE REMOVED DURING

DEMOLITION OF PARTITION/WINDOW WALL

CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING

DUCTWORK

EXISTING JANITOR SINK WALL AND FLOOR ROUGH-IN TO BE

REMOVED. CAP PIPING BELOW FLOOR AND ABANDON IN

PLACE

EXISTING SKYLIGHT TO BE REMOVED

EXISTING ARCADE / CANOPY, METAL FRAMING, CONCRETE

ROOF DECK AND ROOFING TO BE REMOVED

EXISTING FORMED ALUMINUM PANEL CANOPY TO BE

REMOVED

PARTIAL SAW CUT EXISTING ROOFING AND MAINTAIN ROOF

STRUCTURE, SEE STRUCTURAL SHEETS

EXISTING ROOFTOP MECHANICAL UNIT TO BE REMOVED AND

REINSTALLED

EXISTING STOREFRONT SYSTEM TO BE REMOVED

EXISTING ROOF/OVERFLOW DRAINS AND DOWNSPOUT TO BE

REMOVED AND CAP PIPING BELOW FLOOR AS REQUIRED

EXISTING ROOF/OVERFLOW DRAINS AND DOWNSPOUT TO

REMAIN, PROTECT IN PLACE

EXISTING MECHANICAL UNITS TO REMAIN, PROTECT IN PLACE

DURING DEMOLITION

EXISTING CONCRETE EQUIPMENT PAD TO BE DEMOLISHED

DEMOLISH EXISTING CONCRETE RETAINING WALL AND

RAILING

EXISTING STOREFRONT TO BE REMOVED, PROTECTED AND

REINSTALLED.

D17

D18

D19

D10

D20

D21

D22

D23

NEW WORK KEYNOTES

CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING

DUCT WORK TO BE RELOCATED

NEW PARTITION TO MATCH EXISTING. PAINT TO

MATCH EXISTING ADJACENT WALL

NEW FURRING WALL, SEE WALL TYPES. PAINT TO

MATCH ADJACENT WALL

NEW DOOR(S), DOOR FRAME, TRANSOM, THRESHOLD

AND HARDWARE PER DOOR SCHEDULE AE701

NEW CLASS 'A' THERMOPLASTIC PVC MEMBRANE

ROOFING SYSTEM OVER EXISTING ROOF

NEW ALUMINUM STOREFRONT AND DOOR

COORDINATE ALL STRUCTURAL, MECHANICAL,

ELECTRICAL, PLUMBING AND UTILITY REQUIREMENTS

NEW PORTION OF FINISH FLOORING AND BASE TO

MATCH EXISTING. VERIFY EXTENT IN FIELD

NEW STOREFRONT ALUMINUM WINDOW TO MATCH

EXISTING

INFILL AND PATCH METAL PANEL WALL PRIOR TO

NEW CONSTRUCTION

VERIFY ALL (E) PARTITIONS ARE 1 HR FIRE RATED. IF

NOT, PROVIDE 1 HR RATED ASSEMBLY.

NEW EXPANSION JOINT STRUCTURAL & DETAILS

NEW METAL PANEL WALL TO MATCH EXISTING FINISH

EXISTING WALL TO REMAIN

EXISTING WALL TO BE REMOVED

EXISTING DOOR, DOOR FRAME, TRANSOM,

THRESHOLD AND HARDWARE TO BE REMOVED

EXISTING WINDOW TO BE REMOVED

DEMOLITION FLOOR PLAN LEGENDNEW WORK FLOOR PLAN LEGEND

NEW WALL SEE WALL TYPES

NEW SINGLE SWING DOOR, DOOR FRAME,

TRANSOM, THRESHOLD AND HARDWARE

SEE DOOR SCHEDULE

NEW WINDOW

DOOR NUMBER

FOR DOOR SCHEDULE, SEE SHEETS

AE701 & AE702

WALL TYPE

FOR PARTITION TYPE, SEE SHEET AE551

1FH6

STOREFRONT WINDOW NUMBER,

SEE SHEETS AE621

1tSF1

EXISTING AREA NOT IN SCOPE

DEMOLITION ROOF PLAN LEGEND

EXISTING WALL TO REMAIN

EXISTING WALL TO BE REMOVED

EXISTING EQUIPMENT TO BE REMOVED

EXISTING AREA NOT IN SCOPE

CMU

1 HOUR FIRE+SMOKE BARRIER

1 HOUR FIRE BARRIER

2 HOUR FIRE BARRIER

CONCRETE

NON RATED

SMOKE PARTITION

FOR PARTITION TYPES SEE

SHEET AE551

WALL LEGEND

(949) 250-1500

2355 Main Street Suite 220

Irvine

Drawing Title

Approved: Project Director

Project Title

Date

Location

Checked

Building Number

Project Number

Drawing Number

Model Producer

Revisions: Date

CONSULTANTS: ARCHITECT/ENGINEERS:

Office of Facilities

Management o n e e ig h th in c h o n e fo o t 1 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t

VA FORM 08-6231, OCT 1978

D

Department of Veterans Affairs

2 3 4 5 6

C

B

A

/2

/2

:2

:4

P

M C

U s e r s

\d h s ie h .G

K K

\D o c u m e n ts \V

A S

C I-

A d h s ie h .r v t

SEISMIC DEFICIENCY -

SCI & CLC HOSPITAL

3350 LA JOLLA VILLAGE DR.

SAN DIEGO, CA 92037

Checker

BUILDING 11 BASEMENT -

EXISTING/DEMOLITION AND NEW

WORK PLANS

AE100A

664-401

07/19/2019 Author

SCALE: 1/8" = 1'-0"

BLDG 11 BASEMENT EXISTING / DEMOLITION FLOOR PLAN

SCALE: 1/8" = 1'-0"

BLDG 11 BASEMENT FLOOR PLAN - NEW WORK

GENERAL SHEET NOTES SHEET KEYNOTES KEY PLANLEGENDDEMOLITION SHEET NOTES - BUILDING 11GENERAL SHEET NOTES - BUILDING 11 SHEET KEYNOTES - BUILDING 11 .

S

I

T A

E

T S

L

N

E C C

N

O

CFO FILA

R

A I

T

I

CRADE H

E T

REN.: 10-31-19

NO. C-28367

UP

DN

N

BUILDING 11

SCI BUILDING PART 2

1.

2.

3.

4.

5.

6.

7.

8.

CONFIRM ALL EXISTING AND NEW CONDITIONS WITH THE CONTRACT DOCUMENTS. NOTIFY ARCHITECT IMMEDIATELY IN WRITING OF ALL DISCREPANCIES OR CONFLICTS. DIRECTION SHALL BE GIVEN BY ARCHITECT. IF CONTRACTOR PROCEEDS WITHOUT DIRECTION FROM ARCHITECT, IT SHALL BE AT CONTRACTOR'S RISK, AND CONTRACTOR SHALL

BE RESPONSIBLE FOR ALL REQUIRED CORRECTIVE ACTION.

MECHANICAL AND ELECTRICAL DRAWINGS ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO CHECK WITH THE ARCHITECTURAL DRAWINGS BEFORE THE INSTALLATION OF THE ELECTRICAL AND MECHANICAL WORK. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL AND THE CONSULTANT'S DRAWINGS, SHALL BE BROUGHT TO THE RESIDENT ENGINEER'S ATTENTION FOR CLARIFICATION AND WORK INSTALLED IN CONFLICT WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE GENERAL CONTRACTOR AT HIS OWN EXPENSE, AND AT NO EXPENSE TO THE OWNER OR ARCHITECT.

VISIT JOB SITE PRIOR TO BEGINNING WORK AND VERIFY ALL DIMENSIONS AND CONDITIONS.

WHERE WORK OR EQUIPMENT IS INDICATED "N.I.C." (NOT IN CONTRACT) ON THE DRAWINGS, SUCH WORK AND/OR EQUIPMENT SHALL BE PROVIDED BY OTHERS. CONTRACTOR SHALL COORDINATE AND COOPERATE TO EFFECT

SUCH INSTALLATION.

THE CONTRACTOR SHALL PROTECT ALL FINISHED WORK AND SURFACES FROM DAMAGE DURING THE COURSE OF WORK AND SHALL REPLACE AND/OR REPAIR ALL DAMAGE CAUSED BY CONTRACTOR OR SUB-CONTRACTOR

PERSONNEL.

UPON COMPLETION OF WORK, ALL CONSTRUCTION AREAS SHALL BE LEFT BROOM CLEAN AND FREE FROM DEBRIS.

VERIFY POINTS OF CONNECTION, INCLUDING SIZES AND LOCATIONS AND ALL OTHER REQUIRED OPERATING CRITERIA

WITH EQUIPMENT MANUFACTURER.

COORDINATE THE LOCATION AND TYPE OF ALL ACCESS PANELS REQUIRED FOR ACCESSING MECHANICAL, PLUMBING, AND ELECTRICAL AND OTHER BUILDING SYSTEMS WITH ARCHITECT.

FOR ADDITIONAL DEMOLITION NOTES REFER TO DRAWING GI006

PROVIDE CONSTRUCTION BARRIERS TO SEPARATE AREAS UNDER CONSTRUCTION

FROM ADJACENT AREAS.

AIR QUALITY AND INFECTION CONTROL DURING CONSTRUCTION TO COMPLY WITH VA

STANDARDS & REQUIREMENTS AS OUTLINED IN PROJECT MANUAL AND ON DRAWINGS.

DURING CONSTRUCTION PROVIDE CONTINUOUS AND UNOBSTRUCTED EXIT PATH TO

EXISTING EXIT CORRIDORS AND EXIT STAIRS AT ALL TIMES.

AT ALL AREAS REQUIRED TO BE DEMOLISHED BEYOND THE AREA OF RENOVATION,

CONTRACTOR SHALL PATCH, PAINT AND REPAIR ALL FINISH SURFACES, AND REINSTALL

ANY CEILINGS, DUCTS OR LIGHT FIXTURES REQUIRED TO BE REMOVED DURING

DEMOLITION TO RESTORE TO ORIGINAL CONDITION.

FOR ADDITIONAL SCOPE OF DEMOLITION, SEE STRUCTURAL AND MECHANICAL

DRAWINGS.

FOR DEMOLITION OF LIGHTING FIXTURES, HVAC REGISTERS AND OTHER CEILING

DEVICES SEE MECAHNICAL, ELECTRICAL AND PLUMBING DRAWINGS.

DEMOLISH / REMOVE EXISTING MATERIALS, ITEMS OR FINISHES AS NECESSARY TO

PERFORM NEW WORK.

REFER TO STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR ADDITIONL

INFORMATION.

COORDINATE EXTENT OF DEMOLITION / REMOVAL WITH NEW WORK.

FIELD VERIFY ALL EXISTING DIMENSIONS AND CONDITIONS.

3 4 5 6 7 8 9 10

M

N

P

Q

R

3.1 3.2

S.1

T

V

S

5.1 6.26.1

(E) 4

BEDROOM

1B100

(E)

STRETCHER

BATHROOM

1B100A

(E) 3

BEDROOM

1B102

(E)

WHEELCHAIR

1B102A

(E) HAC

1B103

(E) 4

BEDROOM

1B104

(E)

VESTIBULE

109-11

(E) STAIR

NO.1

ST-1

(E) WOMEN

VISITOR'S

TOILET

1A100

(E) MEN

VISITOR'S

TOILET

1A1101

(E)

PHARMACY

1A102

(E) OFFICE

(S)

1A103

(E)

STORAGE

1A104A

(E) OFFICE

(S)

1A105

(E)

PHYSICIAN

1A104

(E) LOBBY

108A-11

AE100F

AE100F

AE100F

D7

COORDINATE EXTENT OF SITE DEMOLITION

WITH NEW CONSTRUCTION PER CIVIL

SHEETS 1CD101 AND 1CD102

D7D9

D1

D7 D8 D5

D8

D5

D8

LINE OF NEW C.I.P. CONCRETE WALL PER

STRUCTURAL.

PROVIDE SHORING FOR EXCAVATION AS

REQUIRED

D22

D17

D17

LIMIT OF WORK

LIMIT OF WORK

LIMIT OF WORK

LI

M

IT

O

F W

O R

K

LI

M

IT

O

F W

O R

K LI

M

IT

O

F W

O R

K

D23

FOR NEW EXITING ROUTE,

REFER TO NEW WORK

PLAN DETAIL 4

3 4 5 6 7

M

N

P

Q

R

3.1 3.2

S.1

T

V

S

5.1 6.26.1

(E) 4

BEDROOM

1B100

(E) STAIR

NO.1

ST-1

(E) WOMEN

VISITOR'S

TOILET

1A100

(E) MEN

VISITOR'S

TOILET

1A1101

(E)

PHARMACY

1A102

(E) OFFICE

(S)

1A103 (E)

STORAGE

1A104A

(E) OFFICE

(S)

1A105

(E)

PHYSICIAN

1A104

(N) OFFICE

109-11

(E)

ARCADE

C1-2

(E) LOBBY

108A-11

(E)

VESTIBULE

C1-3

109-11

REFER TO 1/AE102D FOR NEW SCI

BUILDING CONNECTOR

AE100F

12' - 0" ±

FH6

12' - 0" ±

FH6

6'

2"

ALIGN

SF21

C1-2

C1-2A

FF4

FF3

FF3

LIMIT OF WORK

LIMIT OF WORK

LIMIT OF WORK

LI

M

IT

O

F W

O R

K

LI

M

IT

O

F W

O R

K LI

M

IT

O

F W

O R

K

NEW EXIT ROUTE, SEE GI100 FOR

PATH OF TRAVEL

15 16

M

N

8' - 0" ±

AE100F

9 8

SF20

AE324

15 16

M

N

(E)

DAYROOM

1B112

(E)

CORRIDOR

C1-20A

(E)

BEDROOM

1B110

AE100F

D3D9

D1

D2

D3

D4

D5

D6

D7

D8

D9

D11

D12

D13

D14

D15

D16

DEMOLITION KEYNOTES

EXISTING FLOORING AND BASE TO BE REMOVED, COORDINATE

SAW-CUTTING AND PATCHING OF FLOOR SLAB PER

REQUIREMENTS OF NEW ELEVATOR MACHINE ROOM

EXISTING WALL TO BE REMOVED. CONTRACTOR EXERCISE

EXTREME CARE WHEN DEMOLISHING EXISTING PARTITION TO

PROTECT IN PLACE EXISTING PIPING LOCATED INSIDE

PARTITIONS

EXISTING DOOR, DOOR FRAME, TRANSOM, THRESHOLD AND

HARDWARE TO BE REMOVED

PARTIALLY SAW CUT EXISTING CONCRETE WALL TO THE

EXTENT REQUIRED TO INSTALL NEW DOOR OPENING, SEE

STRUCTURAL SHEETS

EXISTING STEEL COLUMN TO BE REMOVED PER STRUC.

SHEETS

EXISTING WINDOW AND FRAME TO BE REMOVED, COORDINATE

EXTENT OF DEMOLITION WITH FLOOR PLAN

EXISTING SLIDING DOOR, DOOR FRAME, TRANSOM,

THRESHOLD AND HARDWARE TO BE REMOVED

EXISTING METAL PANEL WALL AND COLUMN EXTENSION TO BE

REMOVED

PORTION OF EXISTING FINISH FLOOR TO BE REMOVED DURING

DEMOLITION OF PARTITION/WINDOW WALL

CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING

DUCTWORK

EXISTING JANITOR SINK WALL AND FLOOR ROUGH-IN TO BE

REMOVED. CAP PIPING BELOW FLOOR AND ABANDON IN

PLACE

EXISTING SKYLIGHT TO BE REMOVED

EXISTING ARCADE / CANOPY, METAL FRAMING, CONCRETE

ROOF DECK AND ROOFING TO BE REMOVED

EXISTING FORMED ALUMINUM PANEL CANOPY TO BE

REMOVED

PARTIAL SAW CUT EXISTING ROOFING AND MAINTAIN ROOF

STRUCTURE, SEE STRUCTURAL SHEETS

EXISTING ROOFTOP MECHANICAL UNIT TO BE REMOVED AND

REINSTALLED

EXISTING STOREFRONT SYSTEM TO BE REMOVED

EXISTING ROOF/OVERFLOW DRAINS AND DOWNSPOUT TO BE

REMOVED AND CAP PIPING BELOW FLOOR AS REQUIRED

EXISTING ROOF/OVERFLOW DRAINS AND DOWNSPOUT TO

REMAIN, PROTECT IN PLACE

EXISTING MECHANICAL UNITS TO REMAIN, PROTECT IN PLACE

DURING DEMOLITION

EXISTING CONCRETE EQUIPMENT PAD TO BE DEMOLISHED

DEMOLISH EXISTING CONCRETE RETAINING WALL AND

RAILING

EXISTING STOREFRONT TO BE REMOVED, PROTECTED AND

REINSTALLED.

D17

D18

D19

D10

D20

D21

D22

D23

NEW WORK KEYNOTES

CONTRACTOR TO VERIFY LOCATION OF ALL EXISTING

DUCT WORK TO BE RELOCATED

NEW PARTITION TO MATCH EXISTING. PAINT TO

MATCH EXISTING ADJACENT WALL

NEW FURRING WALL, SEE WALL TYPES. PAINT TO

MATCH ADJACENT WALL

NEW DOOR(S), DOOR FRAME, TRANSOM, THRESHOLD

AND HARDWARE PER DOOR SCHEDULE AE701

NEW CLASS 'A' THERMOPLASTIC PVC MEMBRANE

ROOFING SYSTEM OVER EXISTING ROOF

NEW ALUMINUM STOREFRONT AND DOOR

COORDINATE ALL STRUCTURAL, MECHANICAL,

ELECTRICAL, PLUMBING AND UTILITY REQUIREMENTS

NEW PORTION OF FINISH FLOORING AND BASE TO

MATCH…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .