4.9_ELIN Sheet_W912PB26RA011_8_6Jul26.xlsx

XLSX spreadsheet 131 KB Posted

Attached to
Inspection, Maintenance and Repair Work on Fire Extinguisher Systems at USAG Bavaria, Germany
Solicitation number
W912PB26RA011
Issued by

About this file

This is a revised ELIN (End Line Item Number) sheet for contract W912PB-08-0014, detailing pricing schedules and line items for maintenance and inspection work on fire extinguishing systems across four military communities at USAG Bavaria, Germany. The contract period runs from August 1, 2026, through July 31, 2031, consisting of one base year and four one-year option periods.

The ELIN sheet outlines maintenance services for fire suppression systems across four locations: Vilseck Rose Barracks (RB), Grafenwoehr Tower Barracks (TB), Hohenfels Training Area (HTA), and Garmisch-Partenkirchen (GAP). Services include semiannual and annual maintenance of Ansul, Guardian Kitchen, sprinkler, gas, dry chemical, and spark extinguishing systems; servicing and liquid agent changes for various system types; emergency on-call services available during specified hours; scheduled battery replacements in control boards; sprinkler system inspections after 20-25 years of operation; and monthly record-keeping and inventory management. Work is divided into OMA (Operations and Maintenance Activities) and AFH (Army Family Housing) building categories, with quantities specified for each service type and period. All pricing displays as EUR - 0, indicating this is a pricing template requiring contractor cost proposals. Services are performed in accordance with the Performance Work Statement and classified technical standards, with maintenance occurring on specified days and hours throughout each contract period.

View the file

Other files

File Type Posted
4.4_Attachment 04_OperatManual_Wagner.pdf PDF
4.7_TE_06_Spark Ex_7.6_revised (6Jul26).xlsx XLSX spreadsheet
4.5_Attachment 05 - Manufacturer Guide_GAMA-tronik Kitchen.pdf PDF
4.6_TE_05_Gas Systems_OMA_revised (6Jul26).xlsx XLSX spreadsheet
4.3_Attachment 01 - CLS_411_revised_24JUN.docx DOCX document
4.8_TE_07_Sprinkler_6.7-9.7_revised (30Jun26).xlsx XLSX spreadsheet
4.1_4th Amendment W912PB26RA0110004 SF 30 (2).pdf PDF
4.2 _Vendor Questions - Answers.pdf PDF
Solicitation 3rd Amendment W912PB26RA0110003 SF 30.pdf PDF
Solicitation 2nd Amendment W912PB26RA0110002 SF 30.pdf PDF
S. Site Visit invitation_W912PB26RA011.pdf PDF
S. Solicitation 1st Amendment W912PB26RA0110001 SF 30.pdf PDF
L. TE_06_Spark Extinguishing System_OMA_W912PB26RA011.xlsx XLSX spreadsheet
Q. IRS Form W-14_W9125PB26RA011.pdf PDF
I. TE_03_Dry_Chemical_OMA_W912PB26RA011.xlsx XLSX spreadsheet
B. PWS_FINAL (28Apr26)_W912PB26RA011.pdf PDF
K. TE_05_Gas Systems_OMA_W912PB26RA011.xlsx XLSX spreadsheet
O. TE_09_Wall_Hydrant_OMA_W912PB26RA011.xlsx XLSX spreadsheet
R. IRS Form W-14 - Sample_W912PB26RA011.pdf PDF
E. Attachment 02 - Authorized Personnel Solicitation_W912PB26RA011.pdf PDF
D. Attachment 01 - CLS 411 (21Apr26) FINAL_W912PB26RA011.pdf PDF
M. TE_07_Sprinkler Systems_AFH & OMA_W912PB26RA011.xlsx XLSX spreadsheet
J. TE_04_Fire_Water_Restraint_OMA_W912PB26RA011.xlsx XLSX spreadsheet
F. Attachment 03_Specification_Maintenance_Tasks_Intervals_W912PB26RA011.xlsx XLSX spreadsheet
H. TE_02_Guardian_OMA and AFH_W9125PB26RA011.xlsx XLSX spreadsheet
C. ELIN Sheet_FINAL_W912PB26RA011.xlsx XLSX spreadsheet
P. TE_10_WILO_OMA_W912PB26RA011.xlsx XLSX spreadsheet
N. TE_08_Sprinkler_Dehoust_AFH_W912PB26RA011.xlsx XLSX spreadsheet
G. TE_01_Ansul_OMA_W912PB26RA011.xlsx XLSX spreadsheet
A. Solicitation - W912PB26RA011.pdf PDF
Show all 30

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

CHANGE REQUEST
for Contract # W912PB-08-0014, 2nd Option
Following Line Item must be changed:
ITEMDESCRIPTIONQUANTITYU/IUNITTOTAL
Following Line Item must be changed:
2003Operation of the Recycling Yard in2MO
accordance with Performance Work
Statement, para 2.5.
Operation days: Monday thru Saturday
Fixed Service

Following Line Item must be added:

2010Operation of the Recycling Yard in10MO
accordance with Performance Work
Statement, para 2.5.
Operation days: Tuesday/Thursday/Saturday
Fixed Service

ELIN Total

ELIN SHEET
CONTRACT POP: 01 AUG 2026 - 31 JUL 2027
Base Year (FY26)
Military Community Rose Barracks (RB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
0001Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Vilseck Rose Barracks (RB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

0004 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Vilseck Rose Barracks (RB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Vilseck€ - 0
Military Community Tower Barracks Grafenwoehr (TB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
0007Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Tower Barracks (TB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

0010 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Tower Barracks (TB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Grafenwoehr€ - 0
Military Community Hohenfels Training Area (HTA)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
0013Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Hohenfels Training Area (HTA) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

0016 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Hohenfels€ - 0
Military Community Garmisch - Partenkirchen (GAP)€ 934,013.60
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
0019Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Garmisch-Partenkirchen Area (GAP) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

0022 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Garmisch-Partenkirchen Area (GAP) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Garmisch€ - 0
Consolidation Base Year:
BY Rose Barracks
BY Tower Barracks
BY Hohenfels
BY Garmisch-Partenkirchen
Grand total Basic Year:€ - 0
ELIN SHEET
CONTRACT POP: 01 AUG 2027- 31 JUL 2028
Option Year 1 (FY27)
Military Community Rose Barracks (RB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
1001Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Vilseck Rose Barracks (RB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

1004 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Vilseck Rose Barracks (RB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Vilseck€ - 0
Military Community Tower Barracks Grafenwoehr (TB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
1007Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Tower Barracks (TB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

1010 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Tower Barracks (TB) for AFH Buildings IAW Performance Work Statement and Contract Pricing Schedule ELINs and Subelins 1 AU

AFH
Total Grafenwoehr€ - 0
Military Community Hohenfels Training Area (HTA)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
1013Maintenance Work and safety inspections at the

overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA

1016 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH
Total Hohenfels€ 0.00
Military Community Garmisch - Partenkirchen (GAP)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
1019Maintenance Work and safety inspections at the

overaching fire extinguisher Systems at Garmisch-Partenkirchen Area (GAP) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA

1022 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Garmisch-Partenkirchen Area (GAP) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH
Total Garmisch€ 0.00
Consolidation OY 1
OY 1 Rose Barracks
OY 1 Tower Barracks
OY 1 Hohenfels
OY 1 Garmisch-Partenkirchen
Grand total OY 1:€ 0.00
ELIN SHEET
CONTRACT POP: 01 AUG 2028- 31 July 2029
Option Year 2 (FY28)
Military Community Rose Barracks (RB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
2001Maintenance Work and safety inspections at the

overaching fire extinguisher Systems at Vilseck Rose Barracks (RB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA

2004 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Vilseck Rose Barracks (RB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH
Total Vilseck€ 0.00
Military Community Tower Barracks Grafenwoehr (TB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
2007Maintenance Work and safety inspections at the

overaching fire extinguisher Systems at Tower Barracks (TB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA

2010 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Tower Barracks (TB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH
Total Grafenwoehr€ 0.00
Military Community Hohenfels Training Area (HTA)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
2013Maintenance Work and safety inspections at the

overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA

2016 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH
Total Hohenfels0.00
Military Community Garmisch - Partenkirchen (GAP)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
2019Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Garmisch-Partenkirchen Area (GAP) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

2022 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Garmisch-Partenkirchen Area (GAP) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Garmisch€ - 0
Consolidation OY 2:
OY 2 Rose Barracks
OY 2 Tower Barracks
OY 2 Hohenfels
OY 2 Garmisch-Partenkirchen
Grand total OY 2:€ - 0
ELIN SHEET
CONTRACT POP: 01 AUG 2029 - 31 JUL 2030
Option Year 3 (FY29)
Military Community Rose Barracks (RB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
3001Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Vilseck Rose Barracks (RB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

3004 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Vilseck Rose Barracks (RB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Vilseck€ - 0
Military Community Tower Barracks Grafenwoehr (TB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
3007Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Tower Barracks (TB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

3010 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Tower Barracks (TB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Grafenwoehr€ - 0
Military Community Hohenfels Training Area (HTA)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
3013Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Hohenfels Training Area (HTA) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

3016 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Hohenfels€ - 0
Military Community Garmisch - Partenkirchen (GAP)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
3019Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Garmisch-Partenkirchen Area (GAP) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

3022 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Garmisch-Partenkirchen Area (GAP) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Garmisch€ - 0
Consolidation OY 3:
OY 3 Rose Barracks
OY 3 Tower Barracks
OY 3 Hohenfels
OY 3 Garmisch-Partenkirchen
Grand total OY 3:€ - 0
ELIN SHEET
CONTRACT POP: 01 AUG 2030 - 31 JUL 2031
Option Year 4 (FY30)
Military Community Rose Barracks (RB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
4001Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Vilseck Rose Barracks (RB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

4004 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Vilseck Rose Barracks (RB) for AFH Buildings IAW Performance Work Statement and Contract Pricing Schedule ELINs and Subelins 1 AU

AFH€ - 0
Total Vilseck€ - 0
Military Community Tower Barracks Grafenwoehr (TB)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
4007Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Tower Barracks (TB) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

4010 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Tower Barracks (TB) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Grafenwoehr€ - 0
Military Community Hohenfels Training Area (HTA)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
4013Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Hohenfels Training Area (HTA) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

4016 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Hohenfels Training Area (HTA) for AFH Buildings IAW Performance Work Statement and Contract Pricing Schedule ELINs and Subelins 1 AU

AFH € - 0

Total Hohenfels € - 0

Military Community Garmisch - Partenkirchen (GAP)
CLINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT EURO
4019Maintenance Work and safety inspections at the overaching fire extinguisher

Systems at Garmisch-Partenkirchen Area (GAP) for OMA Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
OMA€ - 0

4022 Maintenance Work and safety inspections at the overaching fire extinguisher Systems at Garmisch-Partenkirchen Area (GAP) for AFH Buildings IAW Performance Work Statement

and Contract Pricing Schedule ELINs and Subelins1AU
AFH€ - 0
Total Garmisch€ - 0
Consolidation OY 4 :
OY 4 Rose Barracks
OY 4 Tower Barracks
OY 4 Hohenfels
OY 4 Garmisch-Partenkirchen
Grand total OY 4:€ - 0

Controlled Unclassified Information - CUI &P/&N

ELIN_RB_Vilseck

BASIC CONTRACT PERIOD - 01 AUG 2026 - 31 JUL 2027
VILSECK ROSE BARRACKS (RB)
Military Community Rose Barracks
CLINELINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT €/$
0001V001Maintenance Work including technical safety inspection at Ansul (incl. Rotarex in Bldg. 150) extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
V002Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
0001V002AASystems at TE 02; OMA Buildings2SVC- 0
0004V002ABSystems at TE 02; AFH Buildings2SVC- 0

0001 V003 Maintenance Work including technical safety inspection at Dry Chemical systems IAW PWS, Attachment 01 - CLS 411 and TE 03 OMA Buildings 1 SVC - 0

0001 V004 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

V005Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
0001V005AASystems OMA Buildings-Annually1SVC- 0
0001V005ABSystems at OMA Buildings-Semi-Annually1SVC- 0
0001V005ACSystems at OMA Buildings-Monthly10SVC- 0
0004V005ADSystems at AFH Buildings-Annually1SVC- 0
0004V005AESystems at AFH Buildings-Semi-Annually1SVC- 0
0004V005AFSystems at AFH Buildings-Monthly10SVC- 0

0001 V006 Maintenance Work including technical safety inspection at a Fire Water Restrain system IAW PWS, Attachment 01 - CLS, TE 04 OMA Building 1 SVC - 0

0001 V007 Maintenance Work including technical required safety inspection at Wall Hydrants IAW PWS, Attachment 01 - CLS 411 and TE 09 OMA Buildings 1 SVC - 0

V008Liquid Servicing of Ansul Systems
0001V008AAChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01 OMA Buildings20EA- 0
0001V008ABChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 and TE 01, OMA Buildings20EA- 0

0001 V009 Servicing of Ansul systems after 10 years of operation IAW PWS and Attachment 01- CLS 411_ OMA Buildings 2 EA - 0

V010Servicing of Guardian Fire Extinguishing Systems
0001V010AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
0004V010ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings25EA- 0
0001V010ACChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings25EA- 0
0004V010ADChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings30EA- 0
0004V010AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings10EA- 0
0001V010AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings1EA- 0
V011Servicing of Guardian Systems after 10 Years IAW PWS and Attachment 01-CLS 411
0001V011AAOMA Buildings5EA- 0
0004V011ABAFH Buildings5EA- 0

V012 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

0001V012AAOMA Buildings1AU- 0
0004V012ABAFH Buildings1AU- 0
0001V012ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
0004V012ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
V013Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
0001V013AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
0001V013ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
0001V013ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
0004V013ADAFH Buildings Monday -Friday 16.00-07.305EA- 0
0004V013AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
0004V013AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
V014Inspection of Sprinkler system after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
0001V014AAOMA Buildings8EA- 0
0004V014ABAFH Buildings2EA- 0
OMA- 0
AFH- 0
Total- 0
Opt. Year 1 - 01 AUG 2027- 31 JUL 2028
VILSECK ROSE BARRACKS (RB)
Military Community Rose Barracks
CLINELINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT €/$
1001V101Maintenance Work including technical safety inspection at Ansul (incl. Rotarex in Bldg. 150) extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
V102Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01-CLS 411, TE 02
1001V102AASystems at TE 02 OMA Buildings2SVC- 0
1004V102ABSystems at TE 02 AFH Buildings2SVC- 0

1001 V103 Maintenance Work including technical safety inspection at Dry Chemical systems IAW PWS, Attachment 01 - CLS 411 and TE 03 OMA Buildings 1 SVC - 0

1001 V104 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

V105Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
1001V105AASystems OMA Buildings-Annually1SVC- 0
1001V105ABSystems OMA Buildings-Semi-Annually1SVC- 0
1001V105ACSystems OMA Buildings-Monthly10SVC- 0
1004V105ADSystems at AFH Buildings-Annually1SVC- 0
1004V105AESystems at AFH Buildings-Semi-Annually1SVC- 0
1004V105AFSystems at AFH Buildings-Monthly10SVC- 0

1001 V106 Maintenance Work including technical safety inspection at a Fire Water Restrain system IAW PWS, Attachment 01 - CLS, TE 04 OMA Building 1 SVC - 0

1001 V107 Maintenance Work including technical required safety inspection at Wall Hydrants IAW PWS, Attachment 01 - CLS 411 and TE 09 OMA Buildings 1 SVC - 0

V108Servicing of Ansul Systems
1001V108AAChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01 OMA Buildings20EA- 0
1001V108ABChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 and TE 01, OMA Buildings20EA- 0

1001 V109 Servicing of Ansul systems after 10 years of operation IAW PWS and Attachment 01- CLS 411_ OMA Buildings, TE 01 2 EA - 0

V110Servicing of Guardian Fire Extinguishing Systems, TE 02
1001V110AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
1004V110ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings25EA- 0
1001V110ACChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings25EA- 0
1004V110ADChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings30EA- 0
1004V110AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings10EA- 0
1001V110AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings1EA- 0
V111Servicing of Guardian Systems after 10 Years IAW PWS and Attachment 01-CLS 411
1001V111AAOMA Buildings5EA- 0
1004V111ABAFH Buildings5EA- 0

V112 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

1001V112AAOMA Buildings1AU- 0
1004V112ABAFH Buildings1AU- 0
1001V112ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
1004V112ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
V113Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
1001V113AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
1001V113ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
1001V113ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
1004V113ADAFH Buildings Monday -Friday 16.00-07.305EA- 0
1004V113AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
1004V113AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
V114Inspection of Sprinkler system after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
1001V114AAOMA Buildings8EA- 0
1004V114ABAFH Buildings2EA- 0
OMA
AFH
Total
Opt. Year 2 - 01 AUG 2028- 31 JUL 2029
VILSECK ROSE BARRACKS (RB)
Military Community Rose Barracks
CLINELINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT €/$
2001V201Maintenance Work including technical safety inspection at Ansul (incl. Rotarex in Bldg. 150) extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
V202Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
2001V202AASystems at TE 02 OMA Buildings2SVC- 0
2004V202ABSystems at TE 02 AFH Buildings2SVC- 0

2001 V203 Maintenance Work including technical safety inspection at Dry Chemical systems IAW PWS, Attachment 01 - CLS 411 and TE 03 OMA Buildings 1 SVC - 0

2001 V204 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

V205Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
2001V205AASystems OMA Buildings-Annually1SVC- 0
2001V205ABSystems OMA Buildings-Semi-Annually1SVC- 0
2001V205ACSystems OMA Buildings-Monthly10SVC- 0
2004V205ADSystems at AFH Buildings-Annually1SVC- 0
2004V205AESystems at AFH Buildings-Semi-Annually1SVC- 0
2004V205AFSystems at AFH Buildings-Monthly10SVC- 0

2001 V206 Maintenance Work including technical safety inspection at a Fire Water Restrain system IAW PWS, Attachment 01 - CLS, TE 04 OMA Building 1 SVC - 0

2001 V207 Maintenance Work including technical required safety inspection at Wall Hydrants IAW PWS, Attachment 01 - CLS 411 and TE 09 OMA Buildings 1 SVC - 0

V208Servicing of Ansul Systems
2001V208AAChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01 OMA Buildings20EA- 0
2001V208ABChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 and TE 01, OMA Buildings20EA- 0

2001 V209 Servicing of Ansul systems after 10 years of operation IAW PWS and Attachment 01- CLS 411_ OMA Buildings 2 EA - 0

V210Servicing of Guardian Fire Extinguishing Systems
2001V210AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
2004V210ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings25EA- 0
2001V210ACChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings25EA- 0
2004V210ADChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings30EA- 0
2004V210AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings10EA- 0
2001V210AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings1EA- 0
V211Servicing of Guardian Systems after 10 Years IAW PWS and Attachment 01-CLS 411
2001V211AAOMA Buildings5EA- 0
2004V211ABAFH Buildings5EA- 0

V212 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

2001V212AAOMA Buildings1AU- 0
2004V212ABAFH Buildings1AU- 0
2001V212ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
2004V212ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
V213Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
2001V213AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
2001V213ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
2001V213ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
2004V213ADAFH Buildings Monday -Friday 16.00-07.305EA- 0
2004V213AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
2004V213AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
V214Inspection of Sprinkler system after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
2001V214AAOMA Buildings8EA- 0
2004V214ABAFH Buildings2EA- 0
OMA
AFH
Total
Opt. Year 3 - 01 AUG 2029- 31 JUL 2030
VILSECK ROSE BARRACKS (RB)
Military Community Rose Barracks
3001V301Maintenance Work including technical safety inspection at Ansul (incl. Rotarex in Bldg. 150) extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
V302Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
3001V302AASystems at TE 02 OMA Buildings2SVC- 0
3004V302ABSystems at TE 02 AFH Buildings2SVC- 0

3001 V303 Maintenance Work including technical safety inspection at Dry Chemical systems IAW PWS, Attachment 01 - CLS 411 and TE 03 OMA Buildings 1 SVC - 0

3001 V304 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

V305Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
3001V305AASystems OMA Buildings-Annually1SVC- 0
3001V305ABSystems OMA Buildings-Semi-Annually1SVC- 0
3001V305ACSystems OMA Buildings-Monthly10SVC- 0
3004V305ADSystems at AFH Buildings-Annually1SVC- 0
3004V305AESystems at AFH Buildings-Semi-Annually1SVC- 0
3004V305AFSystems at AFH Buildings-Monthly10SVC- 0

3001 V306 Maintenance Work including technical safety inspection at a Fire Water Restrain system IAW PWS, Attachment 01 - CLS, TE 04 OMA Building 1 SVC - 0

3001 V307 Maintenance Work including technical required safety inspection at Wall Hydrants IAW PWS, Attachment 01 - CLS 411 and TE 09 OMA Buildings 1 SVC - 0

V308Servicing of Ansul Systems
3001V308AAChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01 OMA Buildings20EA- 0
3001V308ABChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 and TE 01, OMA Buildings20EA- 0

3001 V309 Servicing of Ansul systems after 10 years of operation IAW PWS and Attachment 01- CLS 411_ OMA Buildings 2 EA - 0

V310Servicing of Guardian Fire Extinguishing Systems
3001V310AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
3004V310ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings25EA- 0
3001V310ACChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings25EA- 0
3004V310ADChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings30EA- 0
3004V310AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings10EA- 0
3001V310AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings1EA- 0
V311Servicing of Guardian Systems after 10 Years IAW PWS and Attachment 01-CLS 411
3001V311AAOMA Buildings5EA- 0
3004V311ABAFH Buildings5EA- 0

V312 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

3001V312AAOMA Buildings1AU- 0
3004V312ABAFH Buildings1AU- 0
3001V312ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
3004V312ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
V313Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
3001V313AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
3001V313ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
3001V313ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
3004V313ADAFH Buildings Monday -Friday 16.00-07.305EA- 0
3004V313AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
3004V313AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
V314Inspection of Sprinkler system after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
3001V314AAOMA Buildings8EA- 0
3004V314ABAFH Buildings2EA- 0
OMA
AFH
Total
Opt. Year 4 - 01 AUG 2030- 31 JUL 2031
VILSECK ROSE BARRACKS (RB)
4001V401Maintenance Work including technical safety inspection at Ansul (incl. Rotarex in Bldg. 150) extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
V402Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
4001V402AASystems at TE 02 OMA Buildings2SVC- 0
4004V402ABSystems at TE 02 AFH Buildings2SVC- 0

4001 V403 Maintenance Work including technical safety inspection at Dry Chemical systems IAW PWS, Attachment 01 - CLS 411 and TE 03 OMA Buildings 1 SVC - 0

4001 V404 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

V405Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
4001V405AASystems OMA Buildings-Annually1SVC- 0
4001V405ABSystems OMA Buildings-Semi-Annually1SVC- 0
4001V405ACSystems OMA Buildings-Monthly10SVC- 0
4004V405ADSystems at AFH Buildings-Annually1SVC- 0
4004V405AESystems at AFH Buildings-Semi-Annually1SVC- 0
4004V405AFSystems at AFH Buildings-Monthly10SVC- 0

4001 V406 Maintenance Work including technical safety inspection at a Fire Water Restrain system IAW PWS, Attachment 01 - CLS, TE 04 OMA Building 1 SVC - 0

4001 V407 Maintenance Work including technical required safety inspection at Wall Hydrants IAW PWS, Attachment 01 - CLS 411 and TE 09 OMA Buildings 1 SVC - 0

V408Servicing of Ansul Systems
4001V408AAChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01 OMA Buildings20EA- 0
4001V408ABChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 and TE 01, OMA Buildings20EA- 0

4001 V409 Servicing of Ansul systems after 10 years of operation IAW PWS and Attachment 01- CLS 411_ OMA Buildings 2 EA - 0

V410Servicing of Guardian Fire Extinguishing Systems
4001V410AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
4004V410ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings25EA- 0
4001V410ACChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings25EA- 0
4004V410ADChanging of liquid agent including change of container at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings30EA- 0
4004V410AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings10EA- 0
4001V410AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings1EA- 0
V411Servicing of Guardian Systems after 10 Years IAW PWS and Attachment 01-CLS 411
4001V411AAOMA Buildings5EA- 0
4004V411ABAFH Buildings5EA- 0

V412 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

4001V412AAOMA Buildings1AU- 0
4004V412ABAFH Buildings1AU- 0
4001V412ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
4004V412ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
V413Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
4001V413AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
4001V413ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
4001V413ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
4004V413ADAFH Buildings Monday -Friday 16.00-07.305EA- 0
4004V413AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs5EA- 0
4004V413AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
V414Inspection of Sprinkler system after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
4001V414AAOMA Buildings8EA- 0
4004V414ABAFH Buildings2EA- 0
OMA
AFH
Total

&P/&N

Please note: The numbering has changed since the ELINs for Time and Material (T&M) section Labor Hours as well as section Spare Parts have been eliminated. The 12-series and the 15-series have been removed, so the numbering has shifted.

Vendor Question (AAP list regarding 25 years inspection) subject V116, now V114.

The number V116 has changed from 116 to 114

Vendor Question V012

ELIN_TB_Graf

BASIC CONTRACT PERIOD - 01 AUG 2026 - 31 JUL 2027
GRAFENWOEHR TOWER BARRACKS (TB)
Military Community Tower Barracks
CLINELINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT €/$
0007G001Maintenance Work including technical safety inspection at Ansul extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
G002Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
0007G002AASystems at TE 02 OMA Buildings2SVC- 0
0010G002ABSystems at TE 02 AFH Buildings2SVC- 0
G003Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
0007G003AASystems OMA Buildings-Annually1SVC- 0
0007G003ABSystems OMA Buildings-Semi-Annually1SVC- 0
0007G003ACSystems OMA Buildings-Monthly10SVC- 0
0010G003ADSystems at AFH Buildings-Annually1SVC- 0
0010G003AESystems at AFH Buildings-Semi-Annually1SVC- 0
0010G003AFSystems at AFH Buildings-Monthly10SVC- 0

0007 G004 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

0007 G005 Annual Maintenance of of the WILO-GEP Seperating Station at Bldg #329 + #542 1 SVC - 0

0007 G006 Annual Maintenance and Inspection of Smoke Detectors at Bldg #696; #313; #1363; #720 1 SVC - 0

0007 G007 Maintenance Work (semiannual, annual) including technical safety inspection at Spark Extinguishing System Bldg. 329 Carpenter Shop IAW PWS, Attachment 01 - CLS 411 and TE 06 OMA Buildings 2 SVC - 0

G008Servicing of Ansul Systems
0007G008ABChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01_OMA Buildings20EA- 0
0007G008AAChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 TE 01_OMA Buildings20EA- 0

0007 G009 Inspection of Ansul systems after 10 years of operation IAW PWS and Attachment 01 - CLS 411, OMA Buildings 3 EA - 0

G010Servicing of Guardian Systems
0007G010AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
0010G010ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings50EA- 0
0007G010ACChanging of liquid agent including changing the container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings20EA- 0
0010G010ADChanging of liquid agent including changing the container at Guardian systems IAW PWS and Attachment 01 -CLS 411_AFH Buildings20EA- 0
0010G010AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings5EA- 0
0007G010AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings2EA- 0
G011Safety Inspection of Guardian system after 10 Years of operation IAW PWS and Attachment 01 - CLS 411
0007G011AAOMA Buildings5EA- 0
0010G011ABAFH Buildings5EA- 0

G012 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

0007G012AAOMA Buildings1AU- 0
0010G012ABAFH Buildings1EA- 0
0007G012ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
0010G012ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
G013Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
0007G013AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
0007G013ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs4EA- 0
0007G013ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
0010G013ADAFH Buildings Monday -Friday 16.00-07.3010EA- 0
0010G013AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs4EA- 0
0010G013AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
G014Scheduled replacement of back- up batteries in control boards IAW PWS and Attachment 01 - CLS 411_OMA Buildings
0007G014AAVdS- proofed batteries 12V 7,2 Ah48EA- 0
0007G014ABVdS- proofed batteries 12V 12 Ah10EA- 0
0007G014ACVdS- proofed batteries 12V 18 Ah10EA- 0
G015Scheduled replacement of back- up batteries in control boards IAW PWS and Attachment 01 - CLS 411_AFH Buildings
0010G015AAVdS- proofed batteries 12V 7,2 Ah20EA- 0
0010G015ABVdS- proofed batteries 12V 12 Ah10EA- 0
0010G015ACVdS- proofed batteries 12V 18 Ah10EA- 0
G016Inspection of Sprinkler systems after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
0007G016AAOMA Buildings3EA- 0
0010G016ABAFH Buildings0EA- 0
OMA
AFH
Total
Opt. Year 1 - 01 AUG 2027- 31 JUL 2028
GRAFENWOEHR TOWER BARRACKS (TB)
Military Community Tower Barracks
CLINELINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT €/$
1007G101Maintenance Work including technical safety inspection at Ansul extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
G102Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
1007G102AASystems at TE 02 OMA Buildings2SVC- 0
1010G102ABSystems at TE 02 AFH Buildings2SVC- 0
G103Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
1007G103AASystems OMA Buildings-Annually1SVC- 0
1007G103ABSystems OMA Buildings-Semi-Annually1SVC- 0
1007G103ACSystems OMA Buildings-Monthly10SVC- 0
1010G103ADSystems at AFH Buildings-Annually1SVC- 0
1010G103AESystems at AFH Buildings-Semi-Annually1SVC- 0
1010G103AFSystems at AFH Buildings-Monthly10SVC- 0

1007 G104 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

1007 G105 Annual Maintenance of of the WILO-GEP Seperating Station at Bldg #329 + #542 1 SVC - 0

1007 G106 Annual Maintenance and Inspection of Smoke Detectors at Bldg #313 + #1363 + #696 + #720 1 SVC - 0

1007 G107 Maintenance Work (semiannual, annual) including technical safety inspection at Spark Extinguishing System Bldg. 329 Carpenter Shop IAW PWS, Attachment 01 - CLS 411 and TE 06_OMA Buildings 2 SVC - 0

G108Servicing of Ansul Systems
1007G108ABChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE 01_OMA Buildings20EA- 0
1007G108AAChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 TE 01_OMA Buildings20EA- 0

1007 G109 Inspection of Ansul systems after 10 years of operation IAW PWS and Attachment 01 - CLS 411, OMA Buildings 3 EA - 0

G110Servicing of Guardian Systems
1007G110AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
1010G110ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings50EA- 0
1007G110ACChanging of liquid agent including changing the container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings20EA- 0
1010G110ADChanging of liquid agent including changing the container at Guardian systems IAW PWS and Attachment 01 -CLS 411_AFH Buildings20EA- 0
1010G110AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings5EA- 0
1007G110AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings2EA- 0
G111Safety Inspection of Guardian system after 10 Years of operation IAW PWS and Attachment 01 - CLS 411
1007G111AAOMA Buildings5EA- 0
1010G111ABAFH Buildings5EA- 0

G112 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian etcpp.)

1007G112AAOMA Buildings1AU- 0
1010G112ABAFH Buildings1EA- 0
1007G112ACmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, OMA Bldgs.12EA- 0
1010G112ADmonthly record keeping and generating demanded inventory, repair and financial reports IAW PWS, CLS, AFH Bldgs.12EA- 0
G113Emergency On-Call-Services at all fire extinguishing systems IAW PWS and Attachment 01 - CLS 411
1007G113AAOMA Buildings Monday -Friday 16.00-07.3010EA- 0
1007G113ABOMA Buildings Sat, Sun & Holidays 0-24.00hrs4EA- 0
1007G113ACOMA Buildings Monday-Friday 08.00-16.005EA- 0
1010G113ADAFH Buildings Monday -Friday 16.00-07.3010EA- 0
1010G113AEAFH Buildings Sat, Sun & Holidays 0-24.00hrs4EA- 0
1010G113AFAFH Buildings Monday-Friday 08.00-16.005EA- 0
G114Scheduled replacement of back- up batteries in control boards IAW PWS and Attachment 01 - CLS 411_OMA Buildings
1007G114AAVdS- proofed batteries 12V 7,2 Ah48EA- 0
1007G114ABVdS- proofed batteries 12V 12 Ah10EA- 0
1007G114ACVdS- proofed batteries 12V 18 Ah10EA- 0
G115Scheduled replacement of back- up batteries in control boards IAW PWS and Attachment 01 - CLS 411_AFH Buildings
1010G115AAVdS- proofed batteries 12V 7,2 Ah20EA- 0
1010G115ABVdS- proofed batteries 12V 12 Ah10EA- 0
1010G115ACVdS- proofed batteries 12V 18 Ah10EA- 0
G116Inspection of Sprinkler systems after 20/25 Years of operation IAW PWS and Attachment 01 - CLS 411
1007G116AAOMA Buildings3EA- 0
1010G116ABAFH Buildings0EA- 0
OMA
AFH
Total
Opt. Year 2 - 01 AUG 2028- 31 JUL 2029
GRAFENWOEHR TOWER BARRACKS (TB)
Military Community Tower Barracks
CLINELINDESCRIPTIONQTYU/IUNIT
PRICETOTAL AMOUNT €/$
2007G201Maintenance Work including technical safety inspection at Ansul extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 01 OMA Buildings2SVC- 0
G202Maintenance Work including technical safety inspection at Guardian Kitchen extinguishing systems semiannual and annual IAW PWS, Attachment 01 - CLS 411 and TE 02
2007G202AASystems at TE 02 OMA Buildings2SVC- 0
2010G202ABSystems at TE 02 AFH Buildings2SVC- 0
G203Maintenance Work including technical safety inspection at Sprinkler extinguishing systems IAW PWS, Attachment 01 - CLS 411, TE 07
2007G203AASystems OMA Buildings-Annually1SVC- 0
2007G203ABSystems OMA Buildings-Semi-Annually1SVC- 0
2007G203ACSystems OMA Buildings-Monthly10SVC- 0
2010G203ADSystems at AFH Buildings-Annually1SVC- 0
2010G203AESystems at AFH Buildings-Semi-Annually1SVC- 0
2010G203AFSystems at AFH Buildings-Monthly10SVC- 0

2007 G204 Maintenance Work including technical safety inspections at Gas extinguishing systems IAW PWS, Attachment 01 - CLS 411 and TE 05 OMA Buildings 1 SVC - 0

2007 G205 Annual Maintenance of of the WILO-GEP Seperating Station at Bldg #329 + #542 1 SVC - 0

2007 G206 Annual Maintenance and Inspection of Smoke Detectors at Bldg #313 + #1363 + #696 + #720 1 SVC - 0

2007 G207 Maintenance Work (semiannual, annual) including technical safety inspection at Spark Extinguishing System Bldg. 329 Carpenter Shop IAW PWS, Attachment 01 - CLS 411 and TE 06_OMA Buildings 2 SVC - 0

G208Servicing of Ansul Systems
2007G208ABChanging of liquid agent at Ansul systems IAW PWS, Attachment 01 and TE6.1_OMA Buildings20EA- 0
2007G208AAChanging of liquid agent at Ansul systems including change of container IAW PWS, Attachment 01 - CLS 411 TE 01_OMA Buildings20EA- 0

2007 G209 Inspection of Ansul systems after 10 years of operation IAW PWS and Attachment 01 - CLS 411, OMA Buildings 3 EA - 0

G210Servicing of Guardian Systems
2007G210AAChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings30EA- 0
2010G210ABChanging of liquid agent at Guardian systems IAW PWS and Attachment 01 - CLS 411_AFH Buildings50EA- 0
2007G210ACChanging of liquid agent including changing the container at Guardian systems IAW PWS and Attachment 01 - CLS 411_OMA Buildings20EA- 0
2010G210ADChanging of liquid agent including changing the container at Guardian systems IAW PWS and Attachment 01 -CLS 411_AFH Buildings20EA- 0
2010G210AEExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_AFH Buildings5EA- 0
2007G210AFExchange Guardian Kitchen Hood includes procurement, installation incl. electrical services
IAW PWS and Attachment 01 - CLS 411_OMA Buildings2EA- 0
G211Safety Inspection of Guardian system after 10 Years of operation IAW PWS and Attachment 01 - CLS 411
2007G211AAOMA Buildings5EA- 0
2010G211ABAFH Buildings5EA- 0

G212 Inventory of new fire extinguishing systems into the maintenance cycle and technical exhibit lists (incl. monthly, annual, semiannual) systems at any kind of system at the applicable framework agreement price (Sprinkler, Ansul, Guardian…

This is the start of the file's text. The full file is on GovTribe.