This file is an inventory and maintenance record spreadsheet for a Fire Water Restraint System located at Rose Barracks in Vilseck, Germany, as part of USAG Bavaria operations. The spreadsheet documents detailed technical specifications and maintenance history for fire suppression equipment, including fire extinguishers, sprinkler systems, and related components. Key data fields track equipment manufacturers, serial numbers, agent types and quantities (measured in pounds and kilograms), pressure vessels, pumps, compressors, flow monitoring devices, alarm systems, and component replacement schedules. The system was manufactured by Thomas with model designation T AB VD 011.09.336.1, certified by TUV with specification TH 660/94, weighing 16 kilograms, and originally built in 2009.
This inventory record directly supports the related W912PB26RA011 solicitation issued by the 409th Contracting Command for inspection, maintenance, and repair work on fire extinguisher and sprinkler systems across four USAG Bavaria locations (Grafenwoehr, Vilseck, Hohenfels, and Garmisch) in Germany. The spreadsheet serves as baseline documentation of existing fire suppression infrastructure requiring ongoing maintenance under the anticipated IDIQ contract with performance start date of August 1, 2026. Contractors responding to this solicitation will need to reference such inventory records to understand the scope and complexity of systems requiring preventive maintenance, inspections, component replacements, and repairs throughout the contract period.
View the file
Other files
Show all 30
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
04.01 Vilseck OMA
| TE 04.01_Fire Water Restraint_Rose Barracks Vilseck – OMA | |||
| Inventory # | System | ||
| Discription | Military | ||
| Community | Location | ||
| Detail | Build.# | Building | |
| Detail / Room | Cons. | ||
| Equ.# | Manufacturer | Type | Serial # |
| Manufacturer # | Make |
| Year | # Systems | Lösc hmittel / Extinguish. Agent | Inhalt US Pfund | Inhalt in kg | Treibgas in g | ||||||||||||||||||||
| Blowing Agent | Sprühdüsen | ||||||||||||||||||||||||
| Spray noozle | Handauslösung | ||||||||||||||||||||||||
| Manual release | Signalhupe | ||||||||||||||||||||||||
| Alarm horn | Inhalt Liter | ||||||||||||||||||||||||
| Content litre | Schmelzlot 74 °C | Schmelzlot 100 °C | Schmelzlot 138 °C | Schmelzlot 260 °C | 12 Volt - Akku - Bj | Akkutausch | Sprinkler wet | Sprinkler trocken | NAV "with delay device" | TAV with quick opener | Trennstation / Kombitrenner | Rohrtrenner | Rückschlagklappe ≥ DN80≤DN200 / >DN80 | Steinfänger/Filter | Alarmglocke | Auslösetemperatur | Nenninhalt Vorratsbehälter | Nenninhalt Vorlagebehälter | Sprinklerpumpe | Druckhaltepumpe | Kompressor | Strömungsmelder Standard | Strömungsmeler Zone Check | Überwachungsanlage | Löschmittelflasche |
| Baujahr | Löschmittelflasche | ||||||||||||||||||||||||
| Nr. | Löschmittel | ||||||||||||||||||||||||
| ausgetauscht | Löschmittel | ||||||||||||||||||||||||
| nächster Tausch | Löschmittelbehäl- | ||||||||||||||||||||||||
| ter ausgetauscht | Löschmittelbehäl- | ||||||||||||||||||||||||
| ter nächster Tausch | Strömungsmeler Zone Check | Überwachungsanlage | Schaumbehälter | Nenninhalt Druckluftwasserbehälter | Nenninhalt Vorlagebehälter | Sprinklerpumpe | Förderstrom Sprinklerpumpe | Druckhaltepumpe | Förderstrom Druckhaltepumpe | Kompressor | Strömungswächter | Druckschalter Störung Stadtwasser | Druckschalter Störung Sprinkler | Druckschalter alarm | Löschmittelflasche | ||||||||||
| Baujahr | Löschmittelflasche | ||||||||||||||||||||||||
| Nr. | Löschmittel | ||||||||||||||||||||||||
| ausgetauscht | Löschmittel | ||||||||||||||||||||||||
| nächster Tausch | Löschmittelbehäl- | ||||||||||||||||||||||||
| ter ausgetauscht | Löschmittelbehäl- |
ter nächster Tausch
B 00121 FWR 001 Fire Water Restraint System Rose Barracks 121 1 Thomas T AB VD 011.09.336.1 TÜV TH 660/94 Eigemasse 16 kg 2009